HomeMy WebLinkAboutSUNNY SLOPES LT 4L >T
GREATER ANCHORAGE AREA BOROU(~ ~
HEALTH DEPARTMENT
$27 EAGLE STREET
ANCftORAGE~ ALASKA 99501
27§-2Sll
INSPECT
TI.E:
INDIVIDUAL SEWAGE AND ;'lATER FACILITIES
FOR
Nell Data:
A. Type
B. Depth
C. Size
D. Construction
E. Bacterial Analysis
Sewage Disposal System:
me
Septic Tank (If homemade, show diagram on back)
2, ~ge '~ /~Y
3. Manufacturer (//z'~/f~
Approval Request for~,ge 8 Water Facilities
Page Two ~.
Ce
Seepage/Pit
1. Size
2. Lining
Disposal Field
1. Number of Lines
2. Total Length
Well to Froperty Line
Well to Other Possible Contamination
Foundation to Septic Tank
Foundation to Seepage Pit~9-~ r7~
Seepage Pit to Property Line
7. Required ~easurements
A. Well to Septic Tank
B. Well to Seepage Pit
C. Well to Sewer Line
D.
E.
F.
G.
H,
8. CO~4ENTS:
DISAPPROVED:
DATE:
APPROVAL VALID FOR ONE YEAR FRO~I DATE SIGNED.
GREATER ANCHORAGE AREA BOROUGH HEALTH DEPARnlNENT
EDll70
April 3, 1968
Mr. Dave w, R~hinsoa
Alaska Mutual Savings Bank
§~ Fifth Avenue
Anchorage, Alaska 99501
Lo~ 4, Sunny
Slopes S~divlsfen
Sanitary sewage disposal facilities are not
pmeseu~ly available ko ~he subject ~roperty
and under current Borou~ plannln~ .ill probably
not he available wi~hAn th~ ne~ ~en
Sincerely,
DAVID R. L. DUNCANe
Medical
CPJ/srr
BY:
CYiffo~d P. Judktns, R. ~.
Chief Ssni~ami~n
tJ~'~:orm 2573 ~ '~' Form Approved
Xev. July 195S FEDERAL HOUSING ADMINISTRATION ,,~ Budget Bureau No. 63-R296.8
HEALTH AUTHORITY APPROVAL
INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL SYSTEM
INSURING OFFICE
P~oho~g%
MORTGAGOR OR SPONSOR
SUBDIVISION NAME
TOTAL NUMBER:
WATER SUPPLY BY:
[] Public system
BASEMENT
PART I.--TO BE COMPLETED BY FHA
MORTGAGEE
['~] Community system
SERIAL NO,
PROPERTY ADDRESS
BLOCK NO. LOT NO.
[] New installation
Can attic or other area be made into
additional bedrooms?
~lf Yes, how manfl)
[] Yes [~] No
YSTEM DESIGNED FOR
]Individual .o. OF BDRM$. GARBAGE 01$POSAt
[] Individual [] Yes [] No
SEWAGE DISPOSAL BY:
--]Public system
] Community system
PART II.--TO BE COMPLETED BY HEALTH DEPARTMENT
HEALTH DEPARTMENT INSPECTOR'S SKETCH
It is the opinion of the [] State [] County [] Local Department of Health that this individual water-supply system
[] is [] is not satisfactory as a domestic water supply for the subject property.
It is the opinion of the [] State [] County
tern with proper maintenance:
]Can be expected to function satisfactorily, and
is not likely to create an insanitary condition
] Local Department of Health that this individual sewage-disposal sys-
]Cannot be expected to function satisfactorily
DATE
SIGNATURE
PART Ill.--FOR USE OF FHA OFFICE
TO THE CHIEF UNDERWRITER:
I have reviewed the foregoing and the pertinent FHA Compliance Inspection Report, and recommend that'the
Individual water-supply system be considered [] Acceptable [] Not Acceptable
Sewage disposal be considered [] Acceptable [] Not Acceptable.
SIGNATURE
CHIEF ARCHITECT
DEPUTY FOR CHIEF ARCHITECT
DATE
HEALTH AUTHORITY APPROVAL
INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL SYSTEM
FHA Form 2573
Rev, July 1958
H-W Builders
Star Route 22
ChuE£ak, Alaska
lo,lng described system to serve one 3~bedroom house on each of the ~ubJect
1o ^ propemly constmucted 1,200 gall~ 1Aquia capacity septic
We assume'that the co~mm%ity wate~ supply ~yste~ was installed in a~co~dasae with
amd approved by the Alaska Depa~t~en~ of Heal~h.
~AVID R.' L.
~y
ADAMS · CO~THELL LEE
& ASSOCIATES
CONSULTING ENGINEERS
AFFILIATED WITH
Frank W. Wince, P.E.
WINCE
September 20, 1965
Work Order No. 6705
?I-W Builders
Star Route 22
Chugiak, Alaska
Attention: Mr. Henry Wells
Subject: Percolation tests, Lot 4 & 7, Sunny Slopes Subdivision, Eagle
~ver.
Gentlemen:
In response to your request of September 17, 1965, two percolation
tests were performed in the bottom of excavation dug with a back hoe on
above described lots. The location and soils data are shown on the attached
sheets.
The material encountered from about 1½ feet to 8½ feet was sands and
gravels of such consistency that it would not retain water when run into the
hole. No water table was enoountered at the time of testing.
The seepage rate was too rapid to measure.
Very truly yours,
ADAMS. CORTHELL. LEE.~ArINCE
& ASSOCIATES
Gordon Skrede
GS:sc
Encls,
RICHARD S. ADAMS. P.E. ALAN N. CORTHELI, P.E. HArry R. lee. P.E. FRANK W, WINDE:, P, E,
--~k~/'t Anchorage, Alaska"
Client /J. D/, /3u/zo~-,~.¢ . T.H. No.
FHA No. Tech.
Location-, lot ~ ,Block ,Subdivision.
?EP,.COIATION TEST DA'AR
, A LA S KA T E S T LA I~,
1940 Post Road
Sheet of
WO No.
Date
Depth Soil Class
Fee t · ~ Visual - Unified
Locatio~_S~etch
Reading Date · Gross Time Net Time Depth to H20 Net. Drop
Percolation Rate 1 "/. Minute.