HomeMy WebLinkAboutSUNNY SLOPES LT 10
March 25, 1975
File No.: 4-1
Mr. Luis V. Kuster
P.O. Box 207
Eagle RiVer, Alaska 99577
Dear l'ar, i~uster.
It has been brought to our attention that public sewer is available to
Lot 10, Sunny SloPes Subdivision.
According to Greater Anchorage Area Bo~ough Ordinance, Chapter 16,
Article 16.4§, Section 16,45,090:
"Septic tank~seepage system sewage disposal facilities shall not
be installed or used on any premises where sanitary sewers are
available within se---~enty (70) feet of the nearest lot line of
said premises "
The Greater Anchorage Area Borough Publle Works Department has
checked their records and they indicate that your structure(s) is
not connected to the sanitary sewer, Would you please cheek your
records to verify that the structure(s) is er is not connected and
notify us immediately if your records indicate that a connection
has been made.
If we do not hear from you within seven (7) d~ys, we will assume that
our records are correct. We, therefore, request you connect any and
all structures located on the sub]eot p~ope~y to public sewer during
the 1975 construction season.
You muat apply for a connection permit from the permit officer for the
Greater Anchorage Area Borough, 3§00 East Tudor Road. If you have
any queationa regarding the above, please do not hesitate to contact
the permit officer at 279-fl~86, extension 2§9, or the Department of
EnvirOnmental Quality at 2~4-4~61, extension 141.
Sincerely,
John Lee
Eagle River District SanitaFian
JL/lw
' Form Approved
FHA Form 2573
~. / FEDERAL HOUSING ADMINISTRATION ~.~ Budgel Bureau No. 63-R296.8
HEALTH AUTHORITY APPROVAL
INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL SYSTEM
PART I.mTO BE COMPLETED BY FHA
,Nsu~,.o omcE M~91~I~St National Bank of Anohora ;~ER'AL NO.
Anohorage~ Alaska P.O. Box 720, Anohorage, Alaska 111-000153-203
MORTOAOOR OR SPONSOR PROPBRTY ADDRESS
General Builders 107 Aurora
SUBDIVISION NAME BLOCK NO. LOT~).
Sunny Slopes
TOTAL NUMBER: BASEMENT [] New installation additional bedrooms?
i 3 i [--"]Yes [~No [-']Yes
WATER SUPPLY BY: SYSTEM DESIGNED FOR
[]p~ublic system [] Community system [] Individual .o. OF
SEWAGE DISPOSAL BY~
[] Public system [] Community system [] Individual 3 [] Yes *,-~[] No
t PART II.--TO BE COMPLETED BY HEALTH DEPARTMENT
HEALTH DEPARTMENT INSPECTOR'S SKETCH
I I I I Ill I I I I
I# I I I I I I I I I I I~,,LJ J I JJ I J J I~I.L. %~'1 I I I. } I I I I I I I I I
J II IIIII II II II l Il iii' I'l I I I j
I''Rl'' I'~Z il'' '~''"~ 'J,,,t~,'' ,i,,,,
I-IIL~['" ',,,,,Il ill, ~' ,,,,,, ,,,,,,j ,,,,i,,,,,
JJJ I[[,,],[[ '" I,,~[jJJJJ Il FrlJ,,,,,, ,,,,,,,,,,
iJJJ~j"' IJJllillll'"""
I1,,, ,,i,_,~i ,,t,,,,,I,,,,,,l,,l',,,,,lilJ
iiiiiiiiiIil,[r,~. :. ~,l~',,,,,,.,, ~l, I,,ll,~l,,,I,,,,
I I I II I IJ_LLLLLLLIJXJ_LI P I,,, ...... ,, I! i .........
REPORT OF INspEcTION-INDIVIDUAL SEWAGE-DISPOSAL SYSTEM
Distance from well,~''~' feet. Material, ~"~ee"J
Total liquid capacity. ~,000 gallons. Capacity inlet compartment,
Distance from: Well, feet; foundation,
Number of compartments
~ .gallons.
feet. Liquid depth, feet.
feet; nearest lot line at [] front, [] side, [] rear, feet.
I~;Z~-~ i'
the