HomeMy WebLinkAboutPARADISE VALLEY BLK 1 LT 9Paradis Valley lock I Lot 9 020-424 -29  Municipality of Anchorage · Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 0sP101211 PID Number: 020-424.~1~ Steven Strawn Wastewater System: [] New [] Upgrade Address: 5930 Greece Circle Anchorage, AK 99516 ABSORPTION FIELD 4 [~ DeepTrench I--I Shallow Trench [] Bed [] Mound [] Other: LEGAL DESCRIPTION Sol, Rating: Total Depth from odginal grade: .6 GPD/Ft2 11 Ft. Block: 1 Lot: 9 Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe: Paradise Valley 6 Ft. 5 Ft. Township: Range: Section: Fill added above odginal grade: Gravel Length: 0-1 Ft. 60 Ft. Well: [] New [] Upgrade Gravel width: Number of lines: Dist .... bet .... Ii .... 4 Ft. 1 - Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Existing Ft, Ft. 600 Ft2 ASTM D3034 PVC Ddller: Date Drilled: Static Water Level: installer: Date installed: Ft. Glacier Excavating 10/8-12/2010 Yield: GPM Pump Set at: Casing Height Above Ground: Ft. Ft, TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~To Septic Absorption Lift Holding ~ublic/PrivateManufacturer: Capacity: From% Tank Field Station Tank Sewer Line Anchorage Tank 1,250 Gal. Well N/A N/A N/A N/A >25' Steel Two (2) surface water>100' >100' N/A N/A % / LIFT STATION Lot Line >5' 5 .... N/A N/A Gal. "Pump on" level at: "Pump off' level at: in. High water alarm at: Foundation >5' > 10' N/A N/A in. in. Curtain Drain None Noted / ~ Pump Make & Model Electrical Inspections performed by: Remarks: ***See Lot Line Waiver. BENCH MARK Existing Trench Connected With Flow Splitter Valve. West Entrance Door Threshold. Existing Septic Tank Decommissioned in Accordance 100.0 Ft. with Municipal Code. 11% ~..-/,,j (., ~ ~ ~..&'--~__,-'~J ~1 ~ 3 f~. Erlg~Peer's Stamp, Inspections performed by: A. Harala Dates: 1st 10/8-9/10 2nd 10/9, 11, 12/2010 '~ ~'0.' '~.,!~:~- '.'1-":,". Development Services Department Approval Conditional Approval Date: Reviewed and approved by: .z/,U/~ ~o¢-~Date: _'~ .-/O-// <.~,. ,,,/,,,,, ,,,...~7~..?';/. -/.~. Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Permit Number: OSP101211 t PARADISE VALLEY SUBDIVISION LOT 9, BLOCK 1 LOT 8 NOTE: Existing Septic Tank Decommissioned in Accordance with Municipal Code. 16,126 S.F. FCO Four Bedroom Asphalt Home Dnvewoy Page 2 of 3 PID No. 020-424-90 S l 5¢.5' 40B.9' S2 64.4' I 41.7' FSV 69.2' 43.3' C4 68.0' 59.6' M1 70.4' 58.9' C5 104.9 67,1' , ® \ \ THS LOT 1 8 C5 Alt. Site ALTERNATE SITE Category III System and 15' Long x 5' Wide x 8' Effective Depth Absorption Trench. LOT 17 LEGEND; CO - Cleanout SV - Septic Vent TH - Test Hole MT - Monitor Tube FCO- Foundation Cleon Out THS - Test Hole Spurklond FSV -- Flow Splitter Valve LOT 1 0 PLAN AS-BUILT SCALE 1' = 40' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 -343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP101211 Page 3 of 3 PID No. 020-424-29 Original ~11,250 Gall°n I%, / I SepticTa.k I\ ~8.1--' I I ~7.9 3:: - 90.5 91.0 Original Ground ................ Geotextile Fabdc 85.0- ~ Drainfield Rock 80.0--' o 74'0 Groundwater 9/26/1 (3 60' (Trench Length) O 87.6 79.4.--~ NEW TRENCH 94.0 Geotextile Fabdc Drainfield Rock 36' (Trench Length) EXISTING TRENCH O O PROFILE AS-BUILT No Scale 85.0 87.5 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP101211 02042429000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: September 28, 2010 to September 28, 2011 Design Engineer: ANDERSON ENGINEERING Subdivision: PARADISE VALLEY Site Legal Address: PARADISE VALLEY BLK 1 LT 9 G:3538 Owner/Address: STRAWN STEVEN E 5930 GREECE DR ANCHORAGE AK 995160000 Site Mailing Address: 5930 GREECE DR, Anchorage Lot Size in Sq Ft: 16126 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The Engineer needs to do an additional soils investigation to verify separation to impermiable soils layer and ground water prior to the construction of the septic field. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. Received By:. Issued By: Date: Date: Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 http:llwww.muni,or,qlOnsite Development Services Department On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** WaiverS: OSP101212 COSA#: Permit~: OSP101211 PID#: 020-424-29 Legal Description: Paradise Valley, Block I Lot 9 Engineer: Anderson Engineering Applicant: Steven Strawn 'Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 5.0 feet. This waiver approval applies to the proposed absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: ~'~,~.~ ~---~/~d~ Approved by: ",~,~/~~/~~ Name of Reviewe~ Rec~: 047029 Amount: $320.00 Date Paid: 9/27110 **** VARIANCE/WAIVER REVIEW **** Municipality of Anchorage Development Services Department Building Safety DiviSion On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www. muni.org/onsite (907) 343-7904 ~ ~i' ON-SITE SEWER/WELL PERMIT APPLICATION ~/~,,,...,,,. (~9?/~l?.l'z- FORA SINGLE FAMILY DWELLING Parcel I.D. 020-424-29 Property owner(s) Steven Strawn Mailing address 5930 Greece Drive Anchorage, AK Site address 5930 Greece Drive Anchorage, AK Legal description (Sub'd., Block & Lot) Paradise Valley, Block 1, Lot 9 Legal description (Township, Range & Section) Lot Size 16,126 Sq. Ft. Day phone Zip Code 99516 Zip Code 99516 Number of Bedrooms Four (4) THIS APPLICATION IS FOR ([~ all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authodzed agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: September 26, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 9, Block 1, Paradise Valley Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owners of the subject lot are upgrading the house to 4 bedrooms. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the four-bedroom home. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system. The existing septic tank will be decommissioned in accordance with Municipal Code. The existing absorption trench will be abandoned in place. Also identified on the plans are the locations of the existing well on the lot and those on adjacent lots. No conflicts exist between the proposed septic system location and the wells on this or adjacent lots. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test hole placed on the lot at the location of the existing absorption trench indicated silty gravel with some sand (GM). The percolation rate was determined to be 25 minutes per inch. A recent test hole placed by Spurkland Engineering resulted in a percolation rate of 4.2 minutes per inch. We have designed the system however for the slower percolation rate. We are proposing to construct a 1,250 gallon septic tank and construct a 63' long by 3' wide absorption trench with an 8' effective depth. The distribution pipe in the trench will be placed at 4' below the surface with the total dePth at 12'. The alternate site for the four bedroom home will be a Category III Nitrate reducing system with an application rate of 3 gallons per square foot per day. The trench will be a 15' long x 3' wide x 8' effective depth. A minimum of 3' of cover will be placed over the trench and 4' over the tank. The ground surface on the lot slopes slightly to the west. The trench will be placed LOt 9, Block 1, Paradise Valley September 26, 2010 Page Two parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: o The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ANDERSON ENGINEERING P.O, BOX 240773 ANCHORAGE, AK 99524 522'7773 677-7766 (F~) September 28, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 9, Block 1, Paradise Valley Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: Lot 9, Block 1, Paradise Valley Subdivision is a small lot with only 16,126 square feet of surface area. The existing septic system has failed and must be replaced with a new four bedroom system. Test holes recently placed at the southwest corner indicate silty gravel soils which will support a new absorption system. This area, however, encroaches into the 10' setback from the property line on the west side. Placement of the absorption trench within 5' of the western lot line will not adversely affect neighboring lots. The lots to the south have septic systems at the north end of the lots with the wells to the south. We hereby recommend a lot line waiver be issued allowing placement of the absorption system within 5' of the western lot line. Sincerely, Michael E. Anderson, P.E. 5 Well ~4 5 VACANT 19 2O 21 16 15 10 ExiMing Well 11 ENGLAND AVENUE AREA MAP SCALE 1' = 100' PARADISE LOT LOT 8 NOTE: Abandon Existing Septic Tank in Accordance with Municipal Code. Connect Existing Absorption Trench with Flow Splitter Valve. Total Capacity of New System is 4.7 Bedrooms. SYSTEM REQUIREMENTS: 1,250 Gallon Septic Tank and 60' Long x .9' Wide x 5' Effective Depth Absorption Trench. LOT 1 8 LOT 1 7 NOTE; No Slopes >25% Are Within 50' of the Proposed or Existing Absorption Trenches. VALLEY SUBDIVISION 9, BLOCK 1 16,126 S.F. Well ~ur Bedroom Asphelt Home Dnvewey Site ALTERNATE SITE Category III System and 15' Long x 3' Wide x 8' Effective Depth Absorption Trench. Absorption Area with 4' of Drain Rock. Exoct Limits Unknown. Remove Absorption Moteriol ond 9' of Existing Trench. Ploce Silt Plug in Excavated Area. LOT 1 0 LEGEND: CO - Cleanout SV -- Septic Vent TH - Test Hole MT - Monitor Tulle FCO- Foundation Clean Out THS - Test Hole Spurklond FSV - Flow Splitter Valve SITE PLAN SCALE 1' = 40' LOT 9, BLOCK 1, PARADISE VALLEY SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 2-25 Min./Inch 1,250 Gallon Septic Tank Application Rate: .6 GPD/SF 5' Drainfield Rock NOTE: Existing Trench Satisfies Requirements for Three Bedroom Home. See GEG Adequacy Test. Reduce Trench Length to 37' with Silt Plug. Effective Remaining Area = 37/48 or .77 77 (3 Bedrooms) = 2.31 Bedrooms Remaining Area 1 Bedroom X 150 GPD/.6 GPD/SF (Application Rate) = 250 SF Absorption Area 2500 SF/10 SF/LF = 25 LF Trench Length THEREFORE: Construct a 60' Long x 3' Wide x 5' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 9' Below Existing Ground. Provide 4' Cover OVer Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. NOTE: Trench Upgrade Provides Capacity for Additional 2.4 Bedrooms. Total Effective Area Satisfies Requirements for 4.71 Bedrooms. /"/~Natura~ Backfill Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. ~ M' ' ' ' ~ m~mum 6 Separation From Bedrock. ~,,,,j~ ..................... ~ ..... 2,~ Minimum 4' Separation From Groundwater. M nimum 100' Separation From Wells in the Area ~'~'~'"~;;;~;'E';;~;;;~'"":'~ . . , ' ~ . Minimum 100 Separation From Surface Water or Streams.' ~.~ No. c~.~ 2- 3- 4- 7- 8- 9- 10- 11-i 12- 13- 14- 15- 16- 18- 19- 20- Performed For: Legal Description: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www. ci.anchoraqe,.ak us (907) 343-7904 Soils Log - Percolation Test Mike Blakeslee Paradise Valley Block 1 Lot 9 Slope WAS GROUND WATER ENCOUNTERED? No S F YES, AT WHAT DEPTH9 ...... L O Depth to Water After p Monitoring? ,//~Jo ~ ~ E ~' ,'-.'~" l~ ". 4-t'~ .. z9 ., ,/ l- ~" '~%~' ~ Date 7/~X~~ Pedormed: Township, Range, Section: Site Plan COMMENTS presoaked Reading Date Gross Time Net Time Depth to Water Net Drop 9/7/2010 10:45 am 0 min 11" 8.125 9/712010 10:55 am 10 min 10.875" 2.875" 8.625 9/7/2010 11:05 am 20 rain 10.875 2.25" 8.5 9/712010 11:15 am 30rain 11" 2.375" 8.375 9/7/2010 11:25 am 40 rain 11.125" 2.625" 8.625 9/712010 11:35 am 50 min 11" 2.5" 8.625 9f7/2010 11:45 am 60 rain 2.375" PERCOLATION RATE 4.2 (minutes/inch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 5 FT AND 6 FT PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNIC P L-GI::TfDE~'INES IN EFFECT ON THIS DATE. DATE: 917/2010 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: /Z////~"~/ ,~,~,~,,, ,~/-.,"E' LEGAL DESCRIPTION: ~- ~:;~'"' Township, Range, Section:~//.)~ SLOPE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ! (ENGINLEF~F~_SEAL) I DATE PER~ WAS GROUND WATER ENCOUNTERED? s L IF YES, AT WHAT O DEPTH? P E Depth to Water After Monitoring7 . Date: Gross Net Depth to Net Reading Date Time Time Water Drop ~.,~/~,~ ~/'..,'~,,A. ' ~ " PERCOLATION RATE ~' 7 ' (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND ~"5'"~ FT COMMENTS /~'-'~--~'~' ~"~//[*/ /~"~), C~~ ~~~ ~~ CERTIFY THAT THIS TEST WAS PERFORMED IN PERFORMED BY: ~'~ ~/~///~/~ I < ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4185) Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST UPERFORMED FOR: ,,/~/.~' Z,. ~" ' DATE PERFORMED J~)J LEGAL DESCRIPTION: Township, Range, Section: ,~E-C. // 7'/I/kl Jl,~ ' SLOPE SITE PLAN 18 19 20 o,7// WAS GROUND WATER ENCOUNTERED? ,~--~ S L IF YES, AT WHAT O DEPTH.;' p E Depth to Water Alter Monitoring? ,,O'O~t/~' Date:. Reading Date Gross Net Depth to Net Time Time Water Drop ~ :-~o A .... 2'~'~# - 7 ~ q' o .4 ...~ '~i~'~ PERCOLATION RATE '~ *=~ (minutes/inch) PERC HOLE DIAMETER TEST RUN E~ETWEEN ,.~,.-~" FTAI~D ~""~) FT PERFORMED BY: ~~ ~G/~/~ I~CERTIFY THAT THIS TEST WAS PERFORMED IN 72-008 (Rev. 4/85) I Municipality of Anchorage Page __~_.~_of 7_.- ' DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~"/-*.-/~,~Z'~:~ ~'~4:) PID Number: O ~ ~ Name: /~/~ ~ Wastewater System: ~New ~ Upgrade Address; ~/o~ ~/~. o~ ?~ ABSORPTION FIELD Phone: ~/--~,~ IN°'°fBed~ms: ~epTrench ~ Shallow Trench ~Bed ~Mound LEGAL DESCRIPTION so, Rating: Total Depth from original grade: ~, ~ GPO/Sq. Ft. Subdivision: Depth to pi~ bosom from original grade: Gravel depth beneath pipe WE LL: ~New D Upg fade Gravel depth: Number of lines: Disance.~n lines: Classification (Private, A,B.C): Total Depth: Cased To: Total absorption area: Pipe material: ~/~A~ ~G Ft. 2~ Ft. '~ SO. Ft. Driller: Date Drilled: Static Water Level: Installer: Date installed; Yield: Pump Set at: ~ ~sing H~ight Above Ground: ~ ~PM ~ Ft./ ~ .. ~ TANK SEPARATION DISTANCES ~eptic U Holding D S.T.E.P. TO ~ptlc Absorption Lift Holding Publi~Prlvate Manufacturer: CapaciW in gallons: From T... F~.,U Sa.on ~... S.~..Un. ~ ~C~~ TA~ Number of Compa~ments: Sudace w=t~ ~ W~ ~ wR ~ LIFT STATION LineL°t ~ ~ /~ / ~ ~ ~ / Size in gallons:~ Manufacturer: Cu~ainDrain ~ ~ ~ ~ ~ Pump Make & M~el~ Electrical inspections pedormed by: Remarks: ~~/~ ~ ~ ~~F~ BENCH MARK Lo~tion and Description: I A~um~ Elevation: ~ ~ T/4/~ ~~ , ~ ~, Inspections pe~ormed by: ~, ~~ Dates: ls~~~"~~N%" ' ':;;'"~"""" " .... . Depa~ment of Hea Ith an( ~ ~e~ces approval ft~~ '~ Reviewed and approved b~,: ~. ~~ Date: ~?[/~ 'l~t:-~2~' I~.~i~,~ . 72-013 (1/91) MOA 25 Permit No. '~'/--'V/,,~/-/4~::~'~<~ Page / of ~ Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343~4744 On-Site Wastewater Disposal System and/or Well Inspection Report 72-013 A (2/91) MOA 25 07/27~95 07:34 ANMC RESIDENT ENGINEERS OFFICE ~ TSSC ALASKA ~-W DRILLING, Inc. P. O. BOX 4.1224 * 1~1OC Intetnation~! Airport Road (907) 274-461 l ANCHORAGE, ALASKA 99509 N0.519 ~01 DRILLING LOG Use o~ Well~DOMESTIC- We]/O~er-~Le ~eiu TronQ Location (address of: Township, Range, Section, if known; or distance main road Block 1 Lot 9 Paradise Valley S/D _ Anchnrn~_e Alaska Sl~e of casing--6" Depth of Hole256~-~-----~eet Cased to~254' 83 feet Static water level ~20 ~t. (a~l~) (below) land surface. 'Finish of well (check one) open end ( X ); Screen ( ); Ferforated ( )- Describe screen or pe~oration~ N/A . WeB pumping test a 3t-~3~gall°ns per (~ (minute) for--2 .~ou~s with_.. 30 ._ft. of drawdown fltom static level, DateO~completiOrL~ Ap~.$l 15~ ~9~5 ._ WE~L LOG . . at~i~ ~o~J Depth~n,e~rom ~~ o, m~,,~,~,~~ '' uept. Health & Human Ser~ces G~vel: Sand.)' with C. ob__bles - _.Loose Sand ,' ._~_~~tv?~_mo. 0ccas+~nal Gravel Le~es_ j~,mwn ClaY: Damn~S~'tcky Brown Cl aY_~: Gravell Waterbearln,~ Gr~vel, Bedrock 3s _ 35 ~TO~35 _~38 .TO_. 44 _ 44 TO 95 ._~TO 205 245 ._TO_ 251 251 TO 256 ~WWA-~61~tt~ed Certific"te No's. BI4 & 973 1 -- cuSTOR PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HI/MAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940400 DESIGN ENGINEER:DUMMY COMPANY OWNER NAME:LE HIEU TRONG OWNER ADDRESS:4103 MINNESOTA DRIVE ANCHORAGE, ALASKA 99503 PARCEL ID:02042429 LEGAL DESCRIPTION: PARADISE VALLEY BLK 1 LT 9 DATE ISSUED:10/17/94 EXPIRATION DATE:10/17/95 LOT SIZE: 16126 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE DAT*: September 16, 1994 MOA DHHS 825 'L' Street Anchorage, AK 99502 BATES ENGINEERING 4410CEANVIEW DRIVE ANCHORAGE, AK 99515 (907) 345-0807 SubJ: Well and Septic System Design for Hieu Le Re: L 9, B 1, Paradise Valley Subd. The attached Site Plan shows the existing and potential wells and septic system locations on the surrounding lots. WELL IMPACT The well location was selected based on a compatible location to allow for practical locations for wells and septic systems on the surrounding lots. It is difficult to predict what .impact the total development of the area would have on the available aquifer and beyond the scope of this report, however, because of the size of the lots and density of the subdivision we would 'recommend that some type of a public water be planned for the future. SEPTIC SYSTEM IMPACT The septic system should have little impact on the ground water. The fairly slow perc rates of 27 min/inch thru dense GM material will provide adequate treatment of the effluent. The monitoring tube ( on lot 10) is dry to 12', monitoring tubes on lots 11 and 12 to 14'& 15' are also dry and a test hole drilled on lot 15 by R&M in 1977 recorded no water to a depth of 19.5'. Records reflect that no water was encountered on iota ? or 10 block 2 to depths of 12 and 14 feet. No bedrock or impervious materials were encountered in any of the test holes. Based on this information and the limited space available for septic systems we are requesting approval of a deep trench system using an 8' deep absorption area. During construction we will verify no water to at least 4' below the drain rock and install a monitoring tube. If water is encountered we will immediately notify your office and coordinate a redesign of the system. RESERVE SYSTEM There is adequate space for an alternate system on this lot aa shown on the site plan. We would recommend that consideration be given to a future public sewer system because of the small size of the lots and density of the subdivsion. DRAINAGE The lot generally slopes at banks or other problem areas. about 10% to the west with no cut BA7'~'S ENGINEERING n Design o Construction 0 Resource Development 441 OCEANVIEW DRIVE ANCHORAGE, ALASKA 99515 Telephone (907) 345-0807 CHECKED BY DATE '3~] PERFORMED FOR: I~ LEGAL DESCRIPTION: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 18- 19- 20- COMMENTS #*.-'4,m".*' DATE P E R FO R M E D:~ ~ ~ ~n~t~ Township, Range, Section: ~ // ~//~ ~~ SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT DEPTH? p E Depth to Water After Monitoring? ,,~/0,~ Date: Reading Date Gross Net Depth to Net Time Time Water Drop ~ :~o A ;~/2~'/ . 7~ ~ ~ ~ ~1~'~ PERCOLATION RATE '~ ~'' (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN -~%~'~"-~ FTAND ~'~ FT z~/~ ~,~z'~- ,~/~' ~,,,~' /~//~/9.d. PERFORMED BY' '~"~-/"'~'~" ~"'~,,/G/~'~'~"~,/~4,,~_~ I~CERTIFY THAT THIS TEST WAS · _ PERFORMED IN 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ,~.,~ LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O DATE PERF~ Township, Range, Section:~, SLOPE ~SITE PLAN WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT ~) DEPTH? P E Depth to Water After Monitoring7 Date:. Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ ~ ' (minutes/inch) PERC HOLE DIAMETER ~// TEST RUN BETWEEN ,,~ ¢FT AND '~'5'~' FT PERFORMED BY: .~',,~/X'"~".~ ~;,?~/~/'/4./~'~."~//f,.'/,¢~ I ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE; ~',~,~/~¢~' 72-008 (Rev. 4/85) B,~ ~'"~-,~ ENGINEERING Design ~ Construction [] Resource Development 441 OCEANVIEW DRIVE ANCHORAGE, ALASKA 99515 Telephone (907) 345-0807 CHECKED BY DATE M U N M P L 17Y F Development Services Department On -Site Water & Wastewater Section Certificate of On -Site Systems Approval Phone: 907-343-7904 Fax: 907-343-7997 Parcel I.D. 020-424-29 Expiration Date: 1. GENERAL INFORMATION Complete legal description PARADISE VALLEY BLOCK 1, LOT 9 Location (site address) 5930 GREECE DRIVE, ANCHORAGE, AK 99516 Current property owner(s) ZHIQING GU Mailing address Real estate agent 321 E 45TH STREET. ANCHORAGE. AK 99503 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ® Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 55 b Waiver Fee $ Date of Payment 5 ID/ d, da 1 Date of Payment Receipt Number Receipt Number COSA # O S C z 1 1 a 2 q Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 5/7/2021 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the Pi � • •�!`I��l well and septic system. Therefore, any estimate of how long a system will function satisfactory �rg�•.' • •�1 for current or future occupants or guarantee that no unseen encroachments, deficiencies or ;t" fr discrepancies exist can be given by First Water Consulting & FWI.S *• ' ...49 ......•.. 6. DSD SIGNATURE r Curtis Huffman / _ System #1 Approved for bedrooms �%T . CE 128991 lF�FD SSI�N-�'�' System #2 Approved for bedrooms >(1��PROFESSOP�'� Disapproved Conditional approval for bedrooms, with the following stipulations: SOF <<((�16 ON-SITE t—':_a g WATER AND m J WASTt=VATER Z J`T PKUVF~HM SER��G�� By: Original Certificate Date: S// Z The Municipality of An e Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given i aragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. I/�Sr��G�y:�1�1��►���i COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist Legal Description: PARADISE VALLEY BLOCK 1, LOT 9 Parcel ID: 020-424-29 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA Well log is filed with Onsite (or attached) Date drilled 4/15/1995 Total depth 256 ft Cased to 255 ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 24+ in. Date of flow test for COSA 5/6/2021 Static water level at beginning of test 232 ft. Well production at time of test 4.6 gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 1.38 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date of Sample 4/21/2021 Comments __________________________________________________________________________________ B. TANK DATA Age of tank(s) 10 years Tank type/material SEPTIC / STEEL Measured operating fluid level in septic tank 49” Standpipes/foundation cleanout per record drawing Date of pumping 4/17/2021 C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 10/12/2010 ALL standpipes present per record drawing Total measured depth from grade 9.5 ft (max) Measured depth to pipe invert from grade 4.7 ft (min) N/A – pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective 4.8’ OF THE 5’ ED Code-required soil cover over field System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Adequacy test date 5/6/2021 (TESTED LOWER TRENCH) Results Pass For 4 bedrooms Fluid depth prior to test 27 in Water added 600 gal New depth 36 in Elapsed time 1195 min Final fluid depth 27 in Absorption rate 600 gpd Any rejuvenation treatment (past 12 months) N If yes, enter date Comments/Deficiencies: Per our observations and the 2011 IR there are only COs in the original trench. A monitoring tube will need to be installed in the future in the upper trench to conduct an adequacy test. E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Property Line > 5’ Yes if No ft Absorption Field > 5’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10’ Yes if No ft Property Line > 10’ Yes if No *5 ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No F. ENGINEER’S COMMENTS *EXISTING MOA WAIVER. G. ENGINEER’S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 5/7/21 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-424-29 GENERAL INFORMATION Complete legal description Location (site address) COSA# Expiration Date: Lot 9, Block 1, Paradise Valley Subdivision 5930 Greece Drive Anchorage, AK 99516 Current Property owner(s) Steven Strawn Mailing address 5930 Greece Drive Anchorage, AK 99516 Day phone Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Un/ess otherwise requested; COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: Four (4) TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class ~ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (am) safe,' functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(am) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE ~,,,.,."/ Approved for Disapproved. Conditional approval for bedrooms. Phone 522-7773 Date 3/10/2011 bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Paradise Valley Subdivision, Block 1, Lot 9 A. WELL DATA Parcel ID: 020-424-90 Well type Private Date completed 4/15/95 Total depth 256 ft. IfA, B, or C provide PWSID #~ Sanitary seal (Y/N) Y Cased to 255 ft. FROM WELL LOG Date of test 4/15/95 Static water level 220 Well production 3 WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Arsenic: N/D mg/I SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,250 gal. Foundation cleanout (Y/N) Y Date of pumping New Construction ABSORPTION FIELD DATA g.p.m. Nitrate 1.21 mg/L Date of samp~le: 8/2/10 Number of Compartments Two Depression over tank (Y/N) Pumper Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 8/3/10 235 5.34 g.p.m. Other bacteda o Collected by: GEG, Ltd. colonies/100 mL Date installed ~o/~2/~o & ~o/~9/~4 Soil rating (g.p.d./ft~ or ~lbdrm) .6 GPD/SF Length 60' & 36' ft. Width 4' and 3' ft. Total depth 11-12 ft. Eft. absorption area 1,176 ft2 Monitoring tube Date of adequacy test New Const. Results (Pass/Fail) Fluid depth in absorption field before test in. Water added Elapsed Time: ~ min. Final fluid depth Any rejuvenation treatment (past 12 mo.) (Y/N & type) System type Deep Trench Gravel below pipe 5' & 8' 'ft. Y Depression over field N For bedrooms ~ gal. New de[~th in. in. Absorption rate >= g.p.d. N If yes, give date Y >24 in. Date installed 10/8/2011 Cleanouts (Y/N) Y N High water alarm (Y/N) N LIFT STATION Date' installed "Pump on' level at __ Datum in. E. SEPAI~ATION DISTANCES Size in gallons 'Pump off' level at~ Cycles tested in. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main NIA Sewer/septic service line >25' Animal containment areas >50' Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. On adjacent lots >1oo' On adjacent lots >1oo' Public sewer manholelcleanout Holding tank N/A Manure/animal excrete storage areas N/A >100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Water main N/A Wells on adjacent lots >100' Property line >5' Water service line >10' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field >s' Surface water >1oo' Property line 5 .... Water Service line >1o" Curtain drain None Noted Building foundation >1o' Surface water >1oo' Wells on adjacent lots >1oo' Water main >1o' · Driveway, parking/vehicle storage F. COMMENTS: Existing Absorption Trench Constructed in 1994 Remains in Service and is Connected to Recently Constructedc Absorption Trench With a Flow SplitterValve. ***See Lot Line Waiver. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date Engineer's Printed Name Michael E. Anderson, P.E. COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number GAR. N ESS ENGINEER. IN G GROUp. Ltd. ~;VELL FLOW TEST DATA STREET ADDRESS: CLIENT: PHONE NUMBER; N[YMBER OF BEDROOM: '~ GALLONS PER DAY N WELL ' ~SEE C 0 S A SITE VI ': ~ ' CHECK iST* ~ ~ 1. Casing Height ~c :Ground): 7~~,~ ~'~ 2~ Sanit~y S~]ffYESfi/NNO (if ~Oa. dcsc~be in Comments) 4~ Water S~ples N~ed: ~¢ ~ N~if "YES'", ~te taken' 5, Depression ~ound Well: YES /~if NO'~ descri~in. Co~ems) 6. D0c~ Wall ~d Four Hour Flow 'Test (FHA}: YES / ~) SCALE: 1"= 30' LOT 8 o~~' LOT 18 \ \ \ LOT 17 2.0~ 2,0 LoT9  8352~ (h ' LOT 10 ,,~' ~ .' ~ '.. 9[~ ~ Fred Wal~tka .;~,~ . EASEMENTS OF RECORD, OTHER T~N THOSE SHOWN ON THE RECORDED PLAT A~ NOT SHO~ HEREON. Bumeff BE RECERTIFIED 3-09-1 AS-BUILT NO CORNE~'S SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection of the following described propeity: LOT-g~BEO(~--'J~------- ,, pARADISE VA~ EY SUBDIVISION .Anchorage Recording Precinct, Alaska, and that the Improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvemenls on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 5th _day of AUGUST .,2010 FRED WALATKA & ASSOCIATES (907-248-1666) Engineers and Surveyom · '"~ ' ~ MUNICIPALITY OF ANCHORAGE , ~ ....... ~ HEALTH & HUMAN SERViCEs~ ~ 'attesting to the legality and statuS Of system~ ' ::-.-!';: ::-~' ~ :::: ....... 5. STATEMENT OF INSPECTION BY ENGINEER Ascertified by my seal affixed hereto and as of the validation date shown below, I verify that my ;application shows that the on'site water supply in E :,.~ Disapproved .... ..... '""~ w,,,=~, the following stipulations:' : '~" ~Conditional approval for b~droofiaS,' ' Additional 'Comments Department of Hea th and Human Service~iDHHS) ~ssues Health Authonty on v upon the representations given n paragraph istered in the state Of Alaska. The DHHS doi~s this ~:~:COU'rtesy t6'purchasers o!:h..0mes )rder to satisfy fiertain fedemland state requ'i~:~nts. Employees of DHHS d~'not ~ns or analyze data before a certificate is issued, The Municipality of Anchorage is not responsible for errors or omissions in the profess onal engineer's work:. ':-,:~.:;~,~' 72.025{Rev. 1/91) Back MOA~I Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: /--- ~:~ ~/~/:-~"~:)~':~~ Parcel I.D. A. Well Data Well type Log present (Y/N) Total depth ~ / Cased to Sanitary seal (Y/N) FROM WELL LOG Date of teet ~z/// Static water level Well flow Pump level1 If A, B, or C, attach ADEC letter. ADEC water system number Date completed ~Tz./,y?/~._.<'' Driller -~.~'o~ / Casing height Wires properly protected (Y/N) g.p.m. AT INSPECTION SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot /'~ / Absorption field on lot Public sewer main Sewer service line ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Petroleum tank WATER SAMPLE RESULTS: Coliform /~ Nitrate Date of sample: '7 //7-~ /~,~'~ . ~ ~' Other bacteria Collected by: B. SEPTIC/~ TANK DATA Date installed~ / :/'/~'~'~' Tank size /,~: ~: - Compartments Cleanouts (Y/N) k/ Foundation cleanout (Y/N) \/~ Depression (Y/N) High water alarm (Y/N) /~/,/~ Alarm tested (Y/N) Date of pumping ~//.~ Pumper SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot ./~2 / To property line ~-~' / Surface water/drainage On adjacent lots Absorption field Foundation r-~ 7 / ~service line ~- x~. 72-026 (3/93)' Front CONTINUED ON BACK PAGE C. LIFT STATION ./c//.z~. Date installed Size in gallons Vent (Y/N) High water alarm level "Pump on" level at Manufacturer Manhole/Access (Y/N) "Pump off" Level at Cycles tested Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots Surface water D. ABSORPTION FIELD DATA Date installed Length Width soil rating (GPD/FF) Gravel thickness Cleanout present (Y/N) Results (pass/fail) Total absorption area Date of adequacy test /f/~ Water level in absorption field before test Peroxide treatment (past 12 months) (Y/N) System type ..~C~.J ?~'¢¢~¢//~ Total depth ~¢', ~ 4~¢/ ~ Depressbn over field (Y/N) ~/ ~/~ for ~ Bedr~ms After test ~' ~ .If yes, gbe date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: / Well on lot // To building foundation ~4"-2 / On adjacent lots Surface water Curtain drain /~.///~ On adjacent lots '~ /0 o / Property line To existing or abandoned system on lot Cutbank /f/',//,.z). Wc, tcr ,main/service line Driveway, parking/vehicle storage area ¢¢r.¢ / Lot /.- , ¢' I E. ENGINEER'S CERTIFICATION I certify that l have checked, verified, or conformed to all MOA and HAA guidelines in effe,,.~c4,~~is inspection. ~,~.' ,~ .. 4..-{. - HAA Fee $ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number 72-026 (3/9~)* Back