HomeMy WebLinkAboutPARADISE VALLEY BLK 7 LT 16
Municipality of Anchorage
On -Site Water and Wastewater Section ^ (907) 343-7904 Page 1 oft
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP221207 PID Number: 020-431-05
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New * Upgrade
Name
Mark Schimscheimer
ABSORPTION FIELD
Deep ❑Wide Trench
❑ Dee Trench ❑ Bed ❑ Mound
Site Address
6131 Austria Drive
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
Existing GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Gravel depth beneath pipe
Subdivision Block Lot
Paradise Valley 7 16
Ft.
Ft.
Fill added above original grade
Gravel length
Township Range Section
Ft.
Ft.
Gravel width
Beds: Number of Lines
Distance between lines
SEPARATION DISTANCES
Ft.
Ft.
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ftz
Ft.
Well
101.6'
NA
NA
25'+
TANK ❑® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity
1500 Gal.
Surface Water
100'+
NA
NA
Material
Number of compartments
Lot Line
10'+
NA
NA
NA
HDPE
2
Foundation
13.3
NA
NA
LIFT STATION
Manufacturer
Capacity
Remarks Connected to both existing fields with
Gal.
flow splitter
Alarm location
Electrical installed by
Installer
PIPE MATERIAL House to tank 3034 Tank to 3034
drainfield
Homeowner
Drainfield Co/MT3034
Inspector Pannone Engineering
BENCH MARK (Assumed elevation) 100.0 ft
Inspection ection X51 7/22/22 7/23/22
Location and description
Zed
Td 8/2/22 4th
Garage FF
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional
Approval: Date
.:..
Septic System70;
Approved �� Dated
No : this approval does not include well permit requiremnts.
DESIGN PARAMETERS
UPGRADE SEPTIC SYSTEM
NO. BEDROOM: 4(600 gpd)
TANK SIZE: USED 1500g
ORIGINAL FIELD
SOIL RATING: 306 SF/BR
TOTAL AREA: 1,102 SF
ADEQUATE FOR 3.6 BEDROOMS
EXISTING UPGRADE FIELD
SOIL RATING: 188 SF/BR
TOTAL AREA: 576 SF
ADEQUATE FOR 3.0 BEDROOMS
DESIGN
PARAMETERS
4br RESERVE SEPTIC SYSTEM
NO. BEDROOM:
4(600 gpd)
TANK SIZE:
1500g ADVANTEX
PERC RATE:
13 MPI
SOIL RATING:
5 GPD/SF (CAT III)
AREA REQ'D:
120 SF
USE
CLEAN OUT NO.
20LF x 5'W
x 4.0'ED x 8.0' TD
TOTAL AREA:
200 SF
EXISTING SYSTEM TOTAL
ADEQUATE FOR 6.6 BEDROOMS
N 1
E
Sc
1"=3 W W
DECOMMISSIONED EXISTING t OOOg SEPTIC TANK
INSTALLED 1500g SEPTIC TANK
PER 15.65
WITH DOUBLE CLEAN OUT
AND FLOW SPLITTER
Of
ui
Ln
of
RESERVE FIELD (CAT III)
20LF x 5.0'W x 4.0'ED x 8.0'TD
97.2
W WATER LINE /
B
WELL RADIUS
O
Wo
ABBREVIATIONS
TH
TEST HOLE
J
Z
m
PROPOSED
(E)
J
OJ
CLEAN OUT NO.
FC
U
DU
FS
FLOW SPLITTER
MT
MONITOR TUBE NO.
TYP
W
FF
101.9
-101.9-
25.3
C2(E)
56.0
70.9
C3(E)
40.0
50.6
C4(E)
10.4
26.8
MT=(E)3
47.5
97.2 97.0
1500g GREER
POLY TANK
9�
I
W WATER LINE /
B
WELL RADIUS
RECORD DRAWING
SS NEW SEPTIC
ABBREVIATIONS
TH
TEST HOLE
(P)
PROPOSED
(E)
EXISTING
CO
CLEAN OUT NO.
FC
FOUNDATION
CLEANOUT
FS
FLOW SPLITTER
MT
MONITOR TUBE NO.
TYP
TYPICAL
FF
FINISHED FLOOR
9�
I
C 1 W
SPLITTER / 6-,
\LNEWMT'V
,LOCATED ORIGINAL DRAIN FIELD
AND REPAIRED PIPES
INSTALLED CLEAN OUT AT EACH END
AND INSTALLED MONITOR TUBE AT
BEND IN FIELD
CONNECTED TO FLOW SPLITTER
WITH EXISTING UPGRADE FIELD
NOTES:
A
B
FC 1
RECORD DRAWING
3,7
FC2
SCALE
= 30'
20.9
T1
17.7
18.6
T2
16.6
21.8
DCO
16.5
23.0
TANK
MT
13.1
18.1
NEW
MT
49.7
52.9
C 1(E)
25.5
25.3
C2(E)
56.0
70.9
C3(E)
40.0
50.6
C4(E)
10.4
26.8
MT=(E)3
47.5
C 1 W
SPLITTER / 6-,
\LNEWMT'V
,LOCATED ORIGINAL DRAIN FIELD
AND REPAIRED PIPES
INSTALLED CLEAN OUT AT EACH END
AND INSTALLED MONITOR TUBE AT
BEND IN FIELD
CONNECTED TO FLOW SPLITTER
WITH EXISTING UPGRADE FIELD
NOTES:
PANNONE EMG SVC LLC (C.O. 1088)
P.O. BOX 1807 PAL,!ER, AK 99645
PHONE (907) 745-8200 FAX (907)) 7 745-8201
REVISIONS
Q. '' I
••• •• •• ••••.•• i
"Maven R. anri-R6
p5�/15}23
DATE
03/11/2023
RECORD DRAWING
PARADISE VALLEY, BLOCK 7, LOT 16
MARK SCHIMSCHEIMER
6131 AUSTRIA DRIVE
ANCHORAGE, AK 99516 I
SCALE
= 30'
DRAWN DRM
P.I.D. NO
020-431-05
SITE PLAN
PERMIT 21
osPzz12o7
SHEET
2OF2
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
POBox 1S6h50 4700Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
Permit Number: OSP221207 Effective Date:
Work Type: SapbcTankUpgrodn Expiration Date:
Tax Code Number: 82041305000
Site Legal Address: PARADISE VALLEY 8LK 7LT16 G:3538
Site Mailing Address: G131AUSTRIA DR, Anchorage
Owner: SCH|MSCHE|k4ERMARK A& Lot Size inSqFt:
Design Engineer: PANNONEENGINEERING SERVICES Total Bedrooms:
This permit iofor the construction of:
8/28/2022
S/28/2O23
19101
0 Disposal Field 0Septic Tank [] Holding Tank El Privy 1711 Private Well [] Water Storage
'All construction shaD'bminaccordance with:
1. The attached approved design.
2. All requirements specified inAnchorage Municipal code Chapters 1555 and 15.65
Wastewater Disposal Regulations (1 8AAC72) and Drinking Water Regulations (1 8AAC80)
— The wastewater ~~~` '`,~^~~^'~'~~"='""="'y the installation. ///e engineer ^//uo notify the uuvomprnnnz
Services Department per AMC 15.8G.Provide notification bycalling (9K]7)343 -78O4(24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall boeither:
o. Opened and Closed onthe same day, pr
b. Covered, sealed, and heated to prevent freezing
Received B
Issued By:
2
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 020-413-05
Property owner(s) Mark Schimscheimer
Mailing address 6131 Austria Drive, Anchorage, AK 99516
Site address 6131 Austria Drive
Day phone
Legal description (Sub'd., Block & Lot) Paradise Valley, Block 7, Lot 16
Legal description (Township, Range & Section)
Lot Size 19,101 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) X❑
Septic Tank
X❑
Upgrade Q
(w/wo ADU)
Holding Tank
❑
Renewal ElDuplex
(D) ❑
Privy
❑
Multiple Dwellings ❑
(SF and/or D)
Private Well
❑
Water Storage
❑
-
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: a 5 _ Waiver Fees:
Date of Payment: -/5 .2.02 2 Date of Payment:
Receipt Number: 09 `a W % G Receipt Number:
Permit No. OSP2 0� 1 W q Waiver No.
Permit App_-'-'. .:..,:c
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221207, Deb Wockenfuss, 06/28/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221207, Deb Wockenfuss, 06/28/22
MUNICIPALITY OF ANCHORAGE
Development Services Department t
On -Site Water & Wastewater Section Phone: 907-343-7904
Fax:: 907-343-7997
Septic System Owner -installer Agreement
The On-site Water and Wastewater Section (On-site) may issue an approval for a homeowner
to perform work on an=on -site wastewater disposalsystem to serve that individual's owner -
occupied, single-family or duplex home if the homeowner meets and agrees to the following
requirements:
1. The property owner and excavation equipment operator may perform work on no more
than one owner -installation project in a 12 -month period.
2. Owner's projected active involvement with the installation:
Owber will install the system with assiatnce from uncompensated equipment operator.
Owner has previous experince installing septic systems.
3. The name of the excavation equipment operator: Mike Gribbon
4. I agree that there will be no monetary compensation;, for installation services rendered.
5. The name of the inspecting engineer: Dan Moran, PES
6. 1'agree,to discuss the following items with the inspecting engineer:
a. Permit design criteria and specifications.
b. Inspection requirements set forth in AMC 15.65.070.
c. Advance notice given to the On-site Water & Wastewater Section for all required
municipal inspections (AMC 15.65.070A).
7. 1 agree to have theproject-specificWastewater Disposal System Permit available
at the construction site for the duration of all related work.
8. 1 agree that if the:system is an advanced wastewater treatment system (AWWTS), I will
obtain additional: installation instructions and approval from the equipment distributor.
As owner of (legal` description)_ ParaAI Sc 1 otI(;ey "3 7 1.16
1 agree that the information above is true and accurate.
Owner's printedname: Mark S imscheimer
Owner's signature: Date: 7-21-22
Mailing Address: P. • Box 196650 Anchorage, Alaska 99519-6650 www.muni.org-
r
Jf
r
io
FA
81
C
"
co
i
.m..
ro a
irts
=go
.,g
Z
oo
a
QC
81
C
"
co
i
Municipality of Anchorage Page 1 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW990067 PIDNumber:'~20-413-05
Name:
Terry & Karen Dannenbrinq WastewaterSystem: [] New ~Upgrade
^~dres,: ABSORPTION FIELD
6131 Austria Dr. Anchorage, Ak
Phone: I NO. of Bedrooms:
345-3660 [][Deep Trench [] Shallow Trench r-I Bed E3 Mound [] Other
LE GAL D ESCRI PT IO N Soi, Rating: Total Depth from original grade:
Lot: Elock: Subdivision: Depth to pipe bottom from origina~ grade: Gravel depth beneath pipe
16 7 Paradise Valley 4 Ft. 9
Township; Range: I $eoti~n: Fill added above original grade: Gravel length:
I
0 o 5 Ft, 32 Ft.
WELL: [] New [] Upgrade Gravel width>2' Number of lines: Distance betweenlines:
5 Ft. I NA Ft.
Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material:
Ft. Ft. .~7~ SO. Ft. F81 0. D~30_34
Driller: Date Drilled: Static Water Level:Installer:. Date installed:
Ft. Carl's Excavating 4/29/99
Yield: Pump Set at: Casing Height Above Ground: TAN K - EXISTING
GPM Ft. Ft.
SEPARATION DISTANCES [~Septic [] Holding [] S.T.E.P,
TO Septic Absorption Lift Holding aublic/Private Manufacturer:. Capacity in gallons:
From Tank Field Station Tank sewer un. Greet 1 000
Material: Number of Compartments:
Welt' 1 O0 ' + Steel 2
Su,ace LIFT STATION
Water I 00 ' +
LOt Size in gallons: I Manufacturer:.
Line 10" + "
I
"Pump on" level at: "Pump off" level at: I High water alarm at:
Foundation
1
0
Curtain Pump Make & Model I Electrical Inspections performed by:
Drain NA
I
Remarks: BENCH MARK
Location and Description:
Absorption Field Upgrade Only. Corner Front Porch/Concrete Slab
Existing septic Tank Integrity
I Assumed Elevation:
Verified as OK. 100 f:l,
Inspections pedormed by:
Department of Health and Human Services approval
72-0~3 (Rev. 9/91) MOA25
Permit No. SN9900{;7 Page 2 of 3
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P,O, Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
LegalDescription: Lot 16, Bk 7, Paradise Valley, PIDNo.: 020-413-05
72~13 A (Rev. 9/91) MOA 25
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
(,'%
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Apr 22, 1999
Expiration Date: Apr 21,2000
Permit Number: SW990067
Legal Description: PARADISE VALLEY BLK 7 LT 16
Design Engineer: 0811 Pinard Engineering
Owner Name: Terry & Karen Dannenbring
Owner Address: 6131 AUSTRIA DRIVE
ANCHORAGE , AK 99516-6021
Parcel ID: 020-413-05
Site Address: 006131 AUSTRIA DR
Lot Size: 19101 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is fOr the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special previsions.
The integrity of the septic tank is to be verified and reported on the As-built. If the integrity of the tank is found to be
unacceptable, a new tank is to be installed outside of all well radii and the existing tank decommissioned.
Maximum depth of excavation for trench is 13' from original grade.
Received By: Date:
PINARD ENGINEERING
Paul E. Pinard
Registered Engineer/AK & ID
P.O. Box 871347, Wasilla, Ak 99687
(907)357-ENGR(3647)
Jim Cross
Municipality of Anchorage
Dept of Health & Human Services
Environmental Services Division
825 L. Street, Suite 502
Anchorage, Alaska 99519-6650
April 13, 1999
RE: Lot 16, Block 7, Paradise Valley Subdivision
Dear Mr. Cross:
On March 25, 1999, I performed an adequacy test on the sewer system serving the
referenced property. The test revealed that it was unable to accept a minimum
quantity of flow without a significant rise in liquid levels outside the operational limits of
the system.
The owners, Mr. & Mrs. Terry Dannenbring, are now proceeding with an upgrade of
this system. A testhole was dug, the soils logged and a percolation test performed. A
monitor tube was installed and this afternoon, the site revisited to check on a possible
watertable; no water was encountered. The testhole log and percolation test results are
attached.
A design for the replacement drainfield is also attached. My design specifies a "Deep
Trench" system 32' long with an effective depth of 9', providing 576 sf of absorption area.
The new drainfield will be located approximately 20' to the West of the existing one and
will be connected to the existing septic tank. The MOA specifications for materials,
cleanouts and monitor tubes will be utilized for this installation. A design drawing is
attached.
Groundslopes in the area of the replacement system, as shown on the testhole log, are
slight to moderate, presenting no problems to the installation of the system, as proposed.
Adjacent lots were inspected for possible impacts or conflicts with the replacement
drainfield. None were found. The proposed system is located outside the minimum
protective radius of any existing well, including the well serving this property.
It should be noted that the septic tank is located within the protective radius of the well
which serves the single family residence on the adjacent Lot 17. The owners have stated
that this well was drilled after their sewer system was installed and a cursory review of
MOA records, indicates that a waiver(s) has been issued for Lot 17. Unless inspection of
the septic tank reveals a problem with it's structural integrity, it is planned to leave the tank
in place.
The owners are trying to sell their property and are anxious to complete the upgrade of
this system. Your prompt attention to this proposed upgrade would be appreciated. The
owners have completed a permit application and provided the appropriate fee, both of
which are attached.
Please give me a call if you have any questions in regards to this submittal.
Sincerely,
4 Attachments(as)
cc Terry & Karen Dannenbring, w/attach
Paul E. Pinard, P.E.
0
· 0
0
~I~
0
~m ~
TEST HOLE# I
PINARD ENGINEERING
P.O. Box 871347 Was,la, AK 99687
(907) 357- ENGR (3647)
TEST HOLE LOG / PERCOLATION TEST
DATE: 4/6/99
JOB NUMBER: 99-012
LOCATION: Lot 16, Bk 7, Paridise Valley
FIELD STAFF: A.Wien
DEPTH FEET SOIL TYPE
Topsoil, Fill, Ash &
PT
OL
GM - Silty Sandy Gravel
SLOPE
~ -~- $ ~7'_~
SITE PLAN
Was Ground Water Encountered? Yes /(~
10
11
12
13
14
15
16
19
BOH
w/Boulders. Soiis If YES, Depth to Ground Water.
"Tight" below 15'.
PERCOLATION TEST DATA
-- 4/7/99
A ~me leasureme~ Drop in Le~l Perc Rme
PM
~me (minCe) ,(inches) (Inch.) min./inch Comme~s
820 -- 0.68 --
850 30 0.46 0.22 Refill to 0.67
920 30 0.48 0.19 Refill to 0.67
950 30 0.48 0.19
and ~6 I~T i~"~'EPTH
~.2".. CFM793
COMMENTS; Perc Hole Soaked & MT Set
~~o;~ ........... 'a~ '
On 4/1 3/99.
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAl_ SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL DES~Ri~ON
LOCATION I - ~ ~ NO~ BEDROOMS
~ DISTANCE TO: Wel,~/~O' Absorption,~a-- Dw~
Liq. c~,a~llon~I I~ HOMEMADE: InsidelenBth Width Liquid
~ Z DISTANCE TO: Well Dw~llin~ PEBMIT NO.
O~ ~ ManuFacturer ~a~erial Liquid capaciW Jn ~allons
~ DISTANCE TO: j~ Total ,~,¢f lines Tren~id~ Distan~?~n lines
~ ~
~o. of lines, ~ Ee n
11 U Total area
~ ~ ~ Top of tile to finish grade Material beneath tile
Length~ Width Depth PERMIT NO,
~ ~ Type of crib Crib diameter Crib depth Total effective absorption area
m Well Building foundation Nearest lot line
~ DISTANCE TO:
~ Class Depth Driller Distance to lot line PERMIT NO.
m Building foundation Sewer line Septic tank Absorption area(si
~ DISTANCE TO:
OTHER
SOl L TEST RATING ~
REMARKS I
.....
MtaxIMUH NUHELER OF BEL':,ROOM~E: =
THE F't:. :. ...... ...... r. RE[:, S t ZE OF THE c;,'"~lf ...... RE::E;ORPTiON E;'¢f;~;'I"EH IE;:
THE LENGTH DtFIENt:5:[E)I'.,I l~':.: THE LENGTFt (IN FEET) Of: THE TRENCFI (IFf: DRFIINFIELD.
TNE i:)EPTH OF R TRENCN OR PiT ]:S TNE DISTRNCE BET.WEEN Tt-iE SURFFICE OF THE:
GROUN[:, FIN!} THE BOT'TOH OF' THE EXCR'¢I::ITtON ,.'.'IN FEET).
]"FIE GF.:FtVEL. DEPTH IS THE H. INIMUH DEPTH OF' GRRVEL BETI-,.IEEN THE OUTFRLL. F'IPE
FiND TNE E:OTTOM OF THE EXC:RVF]TION '.'.'IN FEET).
F'E:F.:M:[T FIPPL:EC:F!NT HFIS ]'HE
l:,,E.::,r- L N=, Z E,., L ~_ f ~' TO I NF'ORM TH): '.'5 E:,EPFiRTMENT E:,UF.: ~ NG THE:
..t,:,fI'-~..L.t-]I_N I'.4'g.~:'E-"t"I-t'-,!'::; OF FIN"r' t.,,EI.L::, RE:'JFICENT T')'TH!'q PR]PEF::T'¢ FIND THE
NL!MBER OF F.'!E'E; I [,E' ',~] EZ'F THFIT TFIE HELL H I_L SEF.:VE.
HINIMUM E:,I:STRNCE BETHEEN R I4ELL RND laN') ON-:BITE SEHRGE DISF'O~,FtL.
tE}C~ FEET FOR R F'RI'¢RTE NELL OFt :LSEJ TO 2E~EI FEET FROM Ft F'LtBL, IO t4ELL DEPENDING
UPON THE T'EPE OF' PUBLIC kIEL[ ....
HINIIdUM DItBTRNC:E FROI"1 R PRIVRTE !4EL..L 'TO R PRIVR'T'E S:E!4ER LINE IS ;25 FEET FIND
TO R COI'flMUNITY E;EHER LiNE I5 75 FEET.
WELL LOGS RRE REQUIRED laND MUST BE RE]"URNED TO THE DEF'FIRTMEN]" HITHIN :21:E~ DRYS
OF THE HELL COMPLETION.
OTHER REQUIREMENT2; t"lR'.? RF'PL'¢. SPECIFICRTIONS RND CONSTRUCTION DIRGRRHS FIRE
RVRIL. RE;LE TO INSLtRE PROPER INSTRLLRTION.
! CERTIF'¢ 'TNFtT
::L: I RM FRMILIflR WITH THE REQUIREMENTLE, FOR ON-SITE '.E;E].',!ERS RND HELLS RS 2;ET
FORTH E:'¢ THE HUNICIP~LtTV OF RNCNORRGE.
2: I !.,.!IL.L IN:BTRLL THE :BYS'TEM IN FIC:CORDFtNCE HtTH THE CODE~;.
2: I UNDER~;TRND TFIFfT THE ON-SITE E;Et.,.IER SYSiTEM MR? REQUIRE ENLRR(3EMENT IF' TNE
RESIDENCE IS REidODEL. ED TO INCLUDE HORE THRN :2 BEDROOMS.
V4. E)
'"~'~ ~-%~, ~ SOILS LOG
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchbrage, A)aska 99501 264-47;20
SOILS LOG - PERCOLATION TEST
PERCOLATION
TEST
PERFORMED FOR: -T~7~.~' ~t~/~ j~j~;~J [~r~,l~j~,~ DATE PERFORMED:
LEGAL DESCR,PT,ON:
SLOPE SITE PLAN
1
5
6
7
8
I0
11
~"~12
13
14
15
16
'17
18
19
20
COMMENTS
WAS GROUND WATER /~0 SL
ENCOUNTERED?
O
P
E
IF YES, AT WHAT
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
z_ z.. /:30 ~o ~,u. z~' "/~ " '1~ "
~ ~o0 ,, ~I ~/~" ~]~"
PERCOLATION RATE ~:~ (minutes/inch)
, TEST RUN BETWEEN ¢ FT AND ~' V~, FT
PERFORMED BY: ,/~/,'~-"~ '~'1~'~''~'~
72-008 (6/79)
DRILLING LOG
Well Ow~e~ .:7~ ~t, ez,p~e~ .Use of Well
i',o~tio~ (add~es~ off Tow~sKip, ~se, SeetJo~ if k~ow~; o~ distance main ~o8d
Size of casin~ 6" Depth of Hole L~3 feet Cased to ~2.3 feet
Static water level
Screen ( ); Perforated .( . )i
Describe screen or perforatio- 13~z,,p%'~mbex' lot
~" (K~X) (minute) for
1
Well pumpin~
of drawdown from static
ft. ~8~b~"~:j_ (below) land surface. Finish of well (check one) open end ( :~-' );
hours with
Date of
WELL LOG
penetrated, .Size of material, color and hardness
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHOR ITY
APPROVAL FOR A SINGLE FAMILY DWELLING
020-413-05 HAA#
GENERAL INFORMATION
Complete'legal d~cription
Lot 16, Block 7,
Paradise Valley
Location (site address or directions) 61 31 Austria Dr.
Prope~y owner Terry & Karen Dannenbring Day phone
Mailing address 6131 Austria Dr. Anchoraqe, Alaska
Lending agency None at this time Day phone
Mailin_g address
345-3660
99516
Agent None at this time Day phone
Address
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: 3 '
TYPE OF WATER SUPPLY:
Individual well XX
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
XX
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev, 1/91) Front MOA~21
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm Pinard Enqineerinq
Address PO Bo~%.871 347 ~.. W~n~ I 1~;
Engineer's signature ~ Y--~
Phone (907) 357-3647
Date 5/13/99
DHHS SIGNATURE
^pproved for 7-#/f bedrooms.
Disapproved.
Conditional approval for
bedrooms, with th% following stipulations:
Note: The well for this property meets existing State and Municipal Codes.
There ar~ n~trmt~ nr~nt. Tt ~ ~,~ ~n~ periodic ~=~ ~
performed to insure the wells continued suitability. Current nitrate
More information on nitrates is available from the On-site Services Program,
DHHS, ~-~,~.
Additional Comments
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-O~(Flev, 1,91) Back MOAii~l
DEPARTMENT OF HEALTH &
Environmental SerVices Division
825 L Street, Room 502 · Anchorages Alaska 99,501 ·
Health Authority APp
Legal Description: Lot- 16. Bk 7. Paradise Vallev Parcel I.D.: 020-413-05
A. WELL DATA
Well type ~ If A, B, or C, attachADEC letter. ADEC water system number
Log present (Y/N) y Date completed 9/10/99
Total depth 123 ' Cased to 1 23 ' _ Casing height (above ground)~
Sanitary seal (Y/N). ¥ Wires properly protected (Y/N)
FROM WELL LOG
AT INSPECTION
Date of test 9/10/82 3/25/99
Static water level 55 '
18,2'
Well production 3 g.p.m. 6.9
WATER'SAMPLE RESULTS:
Coliform None Nitrate 8.68- mq/Z Other bacteria
Date of sample: 4/29/99 ; Collected by: Pinard Engineering
B. SEPTIC/HOLDING TANK DATA
Date installed ._~ Tank size 1000 ~ Number of Compartments 2 CleanoUtS (Y/N)
Foundation cleanout (Y/N) ¥ Depression (Y/N) 1~1 High water alarm (Y/N)
Date of PUmping 3/25/99 Puml~er Isaacs Pumpinq Service
C. ABSORPTIONFIELD DATA
Date installed 4/29/99 Soil rating (g.F.--,~, '~ ~"~ c
' 2 '
Length 32 Width .5
Effective absorption area 576 sf - Monitoring Tube pre'sent (Y/N) ¥ Depression over fiel~ (WN)
Date of adequacy test N/A · Resu ts (Pass/FaiI) For
Fluid depth in absorption field before test(in.);
g.p.m
188 System type Deep Trench
I Pipe 9 ' Total dept~h 13 '
N
bedrooms
Immediately after gal. water addedl (in.):
Fluid depth (ins) Minutes later: Absorption rate = g.p.d.
Peroxide treatment (past 12 months) (Y/N)
72-026 (Rev. 3/96)*
If yes, g ve date
D. LIFT STATION
Date installed N/A
Manhole/Access (Y/N)
High water alarm level at*
Cycles tested
E, SEPARATION DISTANCES
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Sewer/septic service line
Size in gallons
"Pump on" level at*
*Datum
SEPARATION DISTANCES FROM WELL ON LOT TO:
100'+
100'+
25'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation 1 ;2 ' Property line 1'0 ' +
Water main/service line 1 0 ' + Surface water/drainage 1 00 ' +
SE PARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Building foundation 1 0 ' +
Property line 1 0 ' +
Surface water 100' +
Curtain drain N/A
F. ENGINEER'S CERTIFICATION
"Pump off" level at*
On adjacent lots 1 00 ~ +
On adjacent lots 1 00 ' +
Public sewer manhole/cleanout N/A
Lift station ~/A
10"+
Absorption field
Wells on adjacent lots 96' (Waiver on
Water main/service line 1 0 ' +
Driveway, parking/vehicle storage area '5 ' +
Wells on adjacent lots 1 00 ' +
I certify that I have determined thru field inspections and r~ are
in conformance with MOA HAA guidelines in effect on this date.
Signature
Engineer's Name
Date
~ - ~,, . - . ,~. ~ ~ .
,view of Municipal r~j~." t~at th~e~le ~' .~. ,
..,
Paul Pinard ~. ~....~ ~
file)
HAA Fee $
Date of Payment
Receipt Number
72-026 (Rev. 3/96)*
Waiver Fee $
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SiTE SEWER AND WATER FACILITY
264-4720
Application Date
GENERAL INFORMATION
(a)
(b)
(c)
Legal D~escription (include lot, block, sub, division, section, tqwnship,
Location (address or directions)
Applicant Name"'~(EL¢ ¢ ~ ¢t-~('.~re-~c'~.~r~ ~TeY'E~hone:* Home aO L~:::) ..-- --!~:x~' Business
Applicant Address ~' IoV~, ~5t-~,¢< ,'--~) ~-. ~-~,,,c.~,.,. ~-
Applicant is (check one): Lending Institution []; Owner/builder ~'; Buyer []; Other [] (explain);
(d) Lending Institution /"~!O(~(;t I.).~,~. '~, C¢('~i~ UCh~Oi~elephone
Address
(e) Real Estate Company and Agent
Address
Telephone
(f)
Mail the HAA to the following address:
TYPE OF RESIDENCE
Singie-Family~ Multi-Family []
Number of Bedrooms
Other
WATER SUPPLY
individual Well'~ Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environ mental Conservation
attesting to the legality and status.
SEWAGE DISPOSAL .,
Onsite ~ Public [] Community [] Holding Ta'nk []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (11/84)
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the numbe~ of bedrooms and type of structure indicated herein~ I further verify that based on the information obtained
from the Muni~!'pality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disp, bsal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm ~a-~Le,~- ~,. ~:~c,.,a-~e:..'5 Telephone i~z{(> ~
Address
Engineer's Seal
DHEP APPROVAL
Approved for ./'/~'~'-~"~ L~,~l~edrooms by
Approved ' )~' ' Disapproved Conditional
Terms of Conditional APproval
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST- FEBRUARY 1984
264-4720
Legal Description: e [(~ I~L~ "'/
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH ~
ENVIRONMENTAL PROTECTION
1986
WELL DATA
Well Classification
Wel Log Present (Y/N)
Total Depth ~-=,~ Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding -ank on Lot
If A. B, C, D.E.C. Approved (Y/N)
Date Completed q-lO- ~. Yield
t,~.~ Depth of Grouting
Pump Set At c~^~K~,n~-
~;~,,~1,'~ .4* Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
, On Adjoining Lots
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
Cleanout/Manhole
Water Sample Collected by
Water Sample Test Results
Comments
; On Adjoining Lots
To Nearest Public Sewer
To Nearest Sewer Serwce Line on Lot
, Date
B. SEPTIC/HOLDING TANK DATA
Date Installed
Standpipes (Y/N) ~ Air-tight Caps (Y/N)
Depression over Tank (Y/N) i'~
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
Size 1o~ No. of Compartments
~ Foundation Cleanout (Y/N) '%//
Date Last Pumped t~-
; for
Temporary Holding Tank Permit (Y/N)
To Water-Supply Well
To Property Line
To Water Main/Service Line
Course --
To Building Foundation
To Disposal Field
To Stream. Pond, Lake. or Major Drainage
Comments
Page 1 of 2
72-026(11/84~
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Type of System Design
Length of Field ~
Depth of Field 12.
Gravel Bed Thickness ~,
Standpipes Present (Y/N)
Date of Last Adequacy Test
Y
7- zz -84,
Square Feet of Absorption Area
Depression over Field (Y/N)
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well tOO
To Building Foundation ~
To Property Line t.~
To Existing or Abandoned System on
Lot ~ ; On Adjoining Lots t (JO-f-
To Water Main/Service Line '--' To Cutbank (if present)
To Stream/Pond/Lake/or Major Drainage Course "'"-
To Driveway, Parking Area, or Vehicle Storage Area
Comments
0 '", -- s u
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have cJ3ecked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed ~t"Y.4~ lt~ Date
CO m pa ny _l~Z~..~ ~.~ ~ MOA No. ~'T'~'-2.~-~
Receipt No. J~ J "'~ ~ [
Date of Payment
Amount: $
Page 2 of 2
72-026 (11/84)
Engineer's Seal
BARTER & ASSOCIATES
10461 HAMPTON DRIVE, ANCHORAGE, ALASKA 99516
PHONE (907) 346-1170, TONY BARTER, P.E.
July 22, 1986
To: Mr. Terry Dannenbring
6131 Austria
Anchorage, Alaska 99516
Ref: Lot 16, Block 7
Paradise Valley Subdivision
Dear Mr. Dannenbring,
At your request, I performed an Adequacy Test on the existing septic
system for the three bedroom residence at the above referenced
location. According to the Greater Anchorage Area Borough's
Inspection report for installation of On-Site Sewage Disposal Systems
at this location (8/26/82), your system consists of a I000 gallon steel
tank and 73 lineal feet of trench.
Upon arriving at the property on July 22, 1986, I observed the septic
system and recorded the static water levels. Water was then
introduced to the system at approximately 7.5 gallons per minute. The
sump at the west end of the trench was monitored for the test. The
water levels were periodically measured and recorded with respect to
time during the filling and subsequent absorbing period. The
absorption rate was extrapolated according to Dr. leroy Reids paper,
"In Situ Testing of On-Site Sewer Systems," September, 1982. The
septic system was in normal use before and after the test.
Water was introduced to the system at 7.5 gallons per minute. I
futher certify that the well sustained a yield of 7.5 gpm for a period
of time in excess of three hours without showing any signs of stress.
On the date tested, this septic system meets the Municipality of
Anchorage sewer and water requirements for a.three~ bedroom
residence.
Sincerely,
Tono W. Barter. P.E.
- APPLIE'--' IT FILLS OUT UppER HAl.' ",ONLY
.eroperty,,Own~ ~ ~. ~ ~ . · Phone
Buyer ~ ~ g
Address Zip Code
Phone
Realty Co. & A.nt ~/~
Address ZiP Code ~
LegalDescription ~~ ~ ~/~/~O~ ~ ~ ~T J~
Type of Resi~nce
~ingle Family
~ Multiple Family No. of Bedrooms ~
~ Other
CSupply
ndividual A~ACH WELL LOG. A w~l Icg is required for all wells drilled since June 1975,
ommunity For wells drilled prior to that date, give well depth (attach Icg if available).
~ Public Utility
Sewer Disposal
~lndividual Year Individual Installed: ~ ~
~ Public Utility When Connected to Public Utility:
~ Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED,
Time Time Time Time
Date Date Date Date
Inspector Inspector Inspector Inspector
MUNICIPALITY OF ANCHUkAGE
Field Notes: J'¢-- ~) b DFr~T C'~ I'=
ENVIRO~, _t
.;cC 2 0 1982
ECE! ED
( .~.~PPROVED BEDROOMS *CONDITIONS OF APPROVAL
( ) DISAPPROVED
( ) CONDITIONAL APPROVAL*
Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received
~ ~ .~..~ ~ ~ ~ Well to Tank Septic Tank Size j
72.023 (3182)