HomeMy WebLinkAboutPARADISE VALLEY BLK 7 LT 16 Municipality of Anchorage On -Site Water and Wastewater Section ^ (907) 343-7904 Page 1 oft ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221207 PID Number: 020-431-05 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New * Upgrade Name Mark Schimscheimer ABSORPTION FIELD Deep ❑Wide Trench ❑ Dee Trench ❑ Bed ❑ Mound Site Address 6131 Austria Drive ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 Existing GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Paradise Valley 7 16 Ft. Ft. Fill added above original grade Gravel length Township Range Section Ft. Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ftz Ft. Well 101.6' NA NA 25'+ TANK ❑® Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1500 Gal. Surface Water 100'+ NA NA Material Number of compartments Lot Line 10'+ NA NA NA HDPE 2 Foundation 13.3 NA NA LIFT STATION Manufacturer Capacity Remarks Connected to both existing fields with Gal. flow splitter Alarm location Electrical installed by Installer PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Homeowner Drainfield Co/MT3034 Inspector Pannone Engineering BENCH MARK (Assumed elevation) 100.0 ft Inspection ection X51 7/22/22 7/23/22 Location and description Zed Td 8/2/22 4th Garage FF ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date .:.. Septic System70; Approved �� Dated No : this approval does not include well permit requiremnts. DESIGN PARAMETERS UPGRADE SEPTIC SYSTEM NO. BEDROOM: 4(600 gpd) TANK SIZE: USED 1500g ORIGINAL FIELD SOIL RATING: 306 SF/BR TOTAL AREA: 1,102 SF ADEQUATE FOR 3.6 BEDROOMS EXISTING UPGRADE FIELD SOIL RATING: 188 SF/BR TOTAL AREA: 576 SF ADEQUATE FOR 3.0 BEDROOMS DESIGN PARAMETERS 4br RESERVE SEPTIC SYSTEM NO. BEDROOM: 4(600 gpd) TANK SIZE: 1500g ADVANTEX PERC RATE: 13 MPI SOIL RATING: 5 GPD/SF (CAT III) AREA REQ'D: 120 SF USE CLEAN OUT NO. 20LF x 5'W x 4.0'ED x 8.0' TD TOTAL AREA: 200 SF EXISTING SYSTEM TOTAL ADEQUATE FOR 6.6 BEDROOMS N 1 E Sc 1"=3 W W DECOMMISSIONED EXISTING t OOOg SEPTIC TANK INSTALLED 1500g SEPTIC TANK PER 15.65 WITH DOUBLE CLEAN OUT AND FLOW SPLITTER Of ui Ln of RESERVE FIELD (CAT III) 20LF x 5.0'W x 4.0'ED x 8.0'TD 97.2 W WATER LINE / B WELL RADIUS O Wo ABBREVIATIONS TH TEST HOLE J Z m PROPOSED (E) J OJ CLEAN OUT NO. FC U DU FS FLOW SPLITTER MT MONITOR TUBE NO. TYP W FF 101.9 -101.9- 25.3 C2(E) 56.0 70.9 C3(E) 40.0 50.6 C4(E) 10.4 26.8 MT=(E)3 47.5 97.2 97.0 1500g GREER POLY TANK 9� I W WATER LINE / B WELL RADIUS RECORD DRAWING SS NEW SEPTIC ABBREVIATIONS TH TEST HOLE (P) PROPOSED (E) EXISTING CO CLEAN OUT NO. FC FOUNDATION CLEANOUT FS FLOW SPLITTER MT MONITOR TUBE NO. TYP TYPICAL FF FINISHED FLOOR 9� I C 1 W SPLITTER / 6-, \LNEWMT'V ,LOCATED ORIGINAL DRAIN FIELD AND REPAIRED PIPES INSTALLED CLEAN OUT AT EACH END AND INSTALLED MONITOR TUBE AT BEND IN FIELD CONNECTED TO FLOW SPLITTER WITH EXISTING UPGRADE FIELD NOTES: A B FC 1 RECORD DRAWING 3,7 FC2 SCALE = 30' 20.9 T1 17.7 18.6 T2 16.6 21.8 DCO 16.5 23.0 TANK MT 13.1 18.1 NEW MT 49.7 52.9 C 1(E) 25.5 25.3 C2(E) 56.0 70.9 C3(E) 40.0 50.6 C4(E) 10.4 26.8 MT=(E)3 47.5 C 1 W SPLITTER / 6-, \LNEWMT'V ,LOCATED ORIGINAL DRAIN FIELD AND REPAIRED PIPES INSTALLED CLEAN OUT AT EACH END AND INSTALLED MONITOR TUBE AT BEND IN FIELD CONNECTED TO FLOW SPLITTER WITH EXISTING UPGRADE FIELD NOTES: PANNONE EMG SVC LLC (C.O. 1088) P.O. BOX 1807 PAL,!ER, AK 99645 PHONE (907) 745-8200 FAX (907)) 7 745-8201 REVISIONS Q. '' I ••• •• •• ••••.•• i "Maven R. anri-R6 p5�/15}23 DATE 03/11/2023 RECORD DRAWING PARADISE VALLEY, BLOCK 7, LOT 16 MARK SCHIMSCHEIMER 6131 AUSTRIA DRIVE ANCHORAGE, AK 99516 I SCALE = 30' DRAWN DRM P.I.D. NO 020-431-05 SITE PLAN PERMIT 21 osPzz12o7 SHEET 2OF2 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program POBox 1S6h50 4700Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 Permit Number: OSP221207 Effective Date: Work Type: SapbcTankUpgrodn Expiration Date: Tax Code Number: 82041305000 Site Legal Address: PARADISE VALLEY 8LK 7LT16 G:3538 Site Mailing Address: G131AUSTRIA DR, Anchorage Owner: SCH|MSCHE|k4ERMARK A& Lot Size inSqFt: Design Engineer: PANNONEENGINEERING SERVICES Total Bedrooms: This permit iofor the construction of: 8/28/2022 S/28/2O23 19101 0 Disposal Field 0Septic Tank [] Holding Tank El Privy 1711 Private Well [] Water Storage 'All construction shaD'bminaccordance with: 1. The attached approved design. 2. All requirements specified inAnchorage Municipal code Chapters 1555 and 15.65 Wastewater Disposal Regulations (1 8AAC72) and Drinking Water Regulations (1 8AAC80) — The wastewater ~~~` '`,~^~~^'~'~~"='""="'y the installation. ///e engineer ^//uo notify the uuvomprnnnz Services Department per AMC 15.8G.Provide notification bycalling (9K]7)343 -78O4(24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall boeither: o. Opened and Closed onthe same day, pr b. Covered, sealed, and heated to prevent freezing Received B Issued By: 2 MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-413-05 Property owner(s) Mark Schimscheimer Mailing address 6131 Austria Drive, Anchorage, AK 99516 Site address 6131 Austria Drive Day phone Legal description (Sub'd., Block & Lot) Paradise Valley, Block 7, Lot 16 Legal description (Township, Range & Section) Lot Size 19,101 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) X❑ Septic Tank X❑ Upgrade Q (w/wo ADU) Holding Tank ❑ Renewal ElDuplex (D) ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ - THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: a 5 _ Waiver Fees: Date of Payment: -/5 .2.02 2 Date of Payment: Receipt Number: 09 `a W % G Receipt Number: Permit No. OSP2 0� 1 W q Waiver No. Permit App_-'-'. .:..,:c Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221207, Deb Wockenfuss, 06/28/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221207, Deb Wockenfuss, 06/28/22 MUNICIPALITY OF ANCHORAGE Development Services Department t On -Site Water & Wastewater Section Phone: 907-343-7904 Fax:: 907-343-7997 Septic System Owner -installer Agreement The On-site Water and Wastewater Section (On-site) may issue an approval for a homeowner to perform work on an=on -site wastewater disposalsystem to serve that individual's owner - occupied, single-family or duplex home if the homeowner meets and agrees to the following requirements: 1. The property owner and excavation equipment operator may perform work on no more than one owner -installation project in a 12 -month period. 2. Owner's projected active involvement with the installation: Owber will install the system with assiatnce from uncompensated equipment operator. Owner has previous experince installing septic systems. 3. The name of the excavation equipment operator: Mike Gribbon 4. I agree that there will be no monetary compensation;, for installation services rendered. 5. The name of the inspecting engineer: Dan Moran, PES 6. 1'agree,to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.070. c. Advance notice given to the On-site Water & Wastewater Section for all required municipal inspections (AMC 15.65.070A). 7. 1 agree to have theproject-specificWastewater Disposal System Permit available at the construction site for the duration of all related work. 8. 1 agree that if the:system is an advanced wastewater treatment system (AWWTS), I will obtain additional: installation instructions and approval from the equipment distributor. As owner of (legal` description)_ ParaAI Sc 1 otI(;ey "3 7 1.16 1 agree that the information above is true and accurate. Owner's printedname: Mark S imscheimer Owner's signature: Date: 7-21-22 Mailing Address: P. • Box 196650 Anchorage, Alaska 99519-6650 www.muni.org- r Jf r io FA 81 C " co i .m.. ro a irts =go .,g Z oo a QC 81 C " co i Municipality of Anchorage Page 1 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW990067 PIDNumber:'~20-413-05 Name: Terry & Karen Dannenbrinq WastewaterSystem: [] New ~Upgrade ^~dres,: ABSORPTION FIELD 6131 Austria Dr. Anchorage, Ak Phone: I NO. of Bedrooms: 345-3660 [][Deep Trench [] Shallow Trench r-I Bed E3 Mound [] Other LE GAL D ESCRI PT IO N Soi, Rating: Total Depth from original grade: Lot: Elock: Subdivision: Depth to pipe bottom from origina~ grade: Gravel depth beneath pipe 16 7 Paradise Valley 4 Ft. 9 Township; Range: I $eoti~n: Fill added above original grade: Gravel length: I 0 o 5 Ft, 32 Ft. WELL: [] New [] Upgrade Gravel width>2' Number of lines: Distance betweenlines: 5 Ft. I NA Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: Ft. Ft. .~7~ SO. Ft. F81 0. D~30_34 Driller: Date Drilled: Static Water Level:Installer:. Date installed: Ft. Carl's Excavating 4/29/99 Yield: Pump Set at: Casing Height Above Ground: TAN K - EXISTING GPM Ft. Ft. SEPARATION DISTANCES [~Septic [] Holding [] S.T.E.P, TO Septic Absorption Lift Holding aublic/Private Manufacturer:. Capacity in gallons: From Tank Field Station Tank sewer un. Greet 1 000 Material: Number of Compartments: Welt' 1 O0 ' + Steel 2 Su,ace LIFT STATION Water I 00 ' + LOt Size in gallons: I Manufacturer:. Line 10" + " I "Pump on" level at: "Pump off" level at: I High water alarm at: Foundation 1 0 Curtain Pump Make & Model I Electrical Inspections performed by: Drain NA I Remarks: BENCH MARK Location and Description: Absorption Field Upgrade Only. Corner Front Porch/Concrete Slab Existing septic Tank Integrity I Assumed Elevation: Verified as OK. 100 f:l, Inspections pedormed by: Department of Health and Human Services approval 72-0~3 (Rev. 9/91) MOA25 Permit No. SN9900{;7 Page 2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O, Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report LegalDescription: Lot 16, Bk 7, Paradise Valley, PIDNo.: 020-413-05 72~13 A (Rev. 9/91) MOA 25 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 (,'% ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Apr 22, 1999 Expiration Date: Apr 21,2000 Permit Number: SW990067 Legal Description: PARADISE VALLEY BLK 7 LT 16 Design Engineer: 0811 Pinard Engineering Owner Name: Terry & Karen Dannenbring Owner Address: 6131 AUSTRIA DRIVE ANCHORAGE , AK 99516-6021 Parcel ID: 020-413-05 Site Address: 006131 AUSTRIA DR Lot Size: 19101 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is fOr the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special previsions. The integrity of the septic tank is to be verified and reported on the As-built. If the integrity of the tank is found to be unacceptable, a new tank is to be installed outside of all well radii and the existing tank decommissioned. Maximum depth of excavation for trench is 13' from original grade. Received By: Date: PINARD ENGINEERING Paul E. Pinard Registered Engineer/AK & ID P.O. Box 871347, Wasilla, Ak 99687 (907)357-ENGR(3647) Jim Cross Municipality of Anchorage Dept of Health & Human Services Environmental Services Division 825 L. Street, Suite 502 Anchorage, Alaska 99519-6650 April 13, 1999 RE: Lot 16, Block 7, Paradise Valley Subdivision Dear Mr. Cross: On March 25, 1999, I performed an adequacy test on the sewer system serving the referenced property. The test revealed that it was unable to accept a minimum quantity of flow without a significant rise in liquid levels outside the operational limits of the system. The owners, Mr. & Mrs. Terry Dannenbring, are now proceeding with an upgrade of this system. A testhole was dug, the soils logged and a percolation test performed. A monitor tube was installed and this afternoon, the site revisited to check on a possible watertable; no water was encountered. The testhole log and percolation test results are attached. A design for the replacement drainfield is also attached. My design specifies a "Deep Trench" system 32' long with an effective depth of 9', providing 576 sf of absorption area. The new drainfield will be located approximately 20' to the West of the existing one and will be connected to the existing septic tank. The MOA specifications for materials, cleanouts and monitor tubes will be utilized for this installation. A design drawing is attached. Groundslopes in the area of the replacement system, as shown on the testhole log, are slight to moderate, presenting no problems to the installation of the system, as proposed. Adjacent lots were inspected for possible impacts or conflicts with the replacement drainfield. None were found. The proposed system is located outside the minimum protective radius of any existing well, including the well serving this property. It should be noted that the septic tank is located within the protective radius of the well which serves the single family residence on the adjacent Lot 17. The owners have stated that this well was drilled after their sewer system was installed and a cursory review of MOA records, indicates that a waiver(s) has been issued for Lot 17. Unless inspection of the septic tank reveals a problem with it's structural integrity, it is planned to leave the tank in place. The owners are trying to sell their property and are anxious to complete the upgrade of this system. Your prompt attention to this proposed upgrade would be appreciated. The owners have completed a permit application and provided the appropriate fee, both of which are attached. Please give me a call if you have any questions in regards to this submittal. Sincerely, 4 Attachments(as) cc Terry & Karen Dannenbring, w/attach Paul E. Pinard, P.E. 0 · 0 0 ~I~ 0 ~m ~ TEST HOLE# I PINARD ENGINEERING P.O. Box 871347 Was,la, AK 99687 (907) 357- ENGR (3647) TEST HOLE LOG / PERCOLATION TEST DATE: 4/6/99 JOB NUMBER: 99-012 LOCATION: Lot 16, Bk 7, Paridise Valley FIELD STAFF: A.Wien DEPTH FEET SOIL TYPE Topsoil, Fill, Ash & PT OL GM - Silty Sandy Gravel SLOPE ~ -~- $ ~7'_~ SITE PLAN Was Ground Water Encountered? Yes /(~ 10 11 12 13 14 15 16 19 BOH w/Boulders. Soiis If YES, Depth to Ground Water. "Tight" below 15'. PERCOLATION TEST DATA -- 4/7/99 A ~me leasureme~ Drop in Le~l Perc Rme PM ~me (minCe) ,(inches) (Inch.) min./inch Comme~s 820 -- 0.68 -- 850 30 0.46 0.22 Refill to 0.67 920 30 0.48 0.19 Refill to 0.67 950 30 0.48 0.19 and ~6 I~T i~"~'EPTH ~.2".. CFM793 COMMENTS; Perc Hole Soaked & MT Set ~~o;~ ........... 'a~ ' On 4/1 3/99. DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAl_ SYSTEM AND/OR WELL INSPECTION REPORT LEGAL DES~Ri~ON LOCATION I - ~ ~ NO~ BEDROOMS ~ DISTANCE TO: Wel,~/~O' Absorption,~a-- Dw~ Liq. c~,a~llon~I I~ HOMEMADE: InsidelenBth Width Liquid ~ Z DISTANCE TO: Well Dw~llin~ PEBMIT NO. O~ ~ ManuFacturer ~a~erial Liquid capaciW Jn ~allons ~ DISTANCE TO: j~ Total ,~,¢f lines Tren~id~ Distan~?~n lines ~ ~ ~o. of lines, ~ Ee n 11 U Total area ~ ~ ~ Top of tile to finish grade Material beneath tile Length~ Width Depth PERMIT NO, ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area m Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. m Building foundation Sewer line Septic tank Absorption area(si ~ DISTANCE TO: OTHER SOl L TEST RATING ~ REMARKS I ..... MtaxIMUH NUHELER OF BEL':,ROOM~E: = THE F't:. :. ...... ...... r. RE[:, S t ZE OF THE c;,'"~lf ...... RE::E;ORPTiON E;'¢f;~;'I"EH IE;: THE LENGTH DtFIENt:5:[E)I'.,I l~':.: THE LENGTFt (IN FEET) Of: THE TRENCFI (IFf: DRFIINFIELD. TNE i:)EPTH OF R TRENCN OR PiT ]:S TNE DISTRNCE BET.WEEN Tt-iE SURFFICE OF THE: GROUN[:, FIN!} THE BOT'TOH OF' THE EXCR'¢I::ITtON ,.'.'IN FEET). ]"FIE GF.:FtVEL. DEPTH IS THE H. INIMUH DEPTH OF' GRRVEL BETI-,.IEEN THE OUTFRLL. F'IPE FiND TNE E:OTTOM OF THE EXC:RVF]TION '.'.'IN FEET). F'E:F.:M:[T FIPPL:EC:F!NT HFIS ]'HE l:,,E.::,r- L N=, Z E,., L ~_ f ~' TO I NF'ORM TH): '.'5 E:,EPFiRTMENT E:,UF.: ~ NG THE: ..t,:,fI'-~..L.t-]I_N I'.4'g.~:'E-"t"I-t'-,!'::; OF FIN"r' t.,,EI.L::, RE:'JFICENT T')'TH!'q PR]PEF::T'¢ FIND THE NL!MBER OF F.'!E'E; I [,E' ',~] EZ'F THFIT TFIE HELL H I_L SEF.:VE. HINIMUM E:,I:STRNCE BETHEEN R I4ELL RND laN') ON-:BITE SEHRGE DISF'O~,FtL. tE}C~ FEET FOR R F'RI'¢RTE NELL OFt :LSEJ TO 2E~EI FEET FROM Ft F'LtBL, IO t4ELL DEPENDING UPON THE T'EPE OF' PUBLIC kIEL[ .... HINIIdUM DItBTRNC:E FROI"1 R PRIVRTE !4EL..L 'TO R PRIVR'T'E S:E!4ER LINE IS ;25 FEET FIND TO R COI'flMUNITY E;EHER LiNE I5 75 FEET. WELL LOGS RRE REQUIRED laND MUST BE RE]"URNED TO THE DEF'FIRTMEN]" HITHIN :21:E~ DRYS OF THE HELL COMPLETION. OTHER REQUIREMENT2; t"lR'.? RF'PL'¢. SPECIFICRTIONS RND CONSTRUCTION DIRGRRHS FIRE RVRIL. RE;LE TO INSLtRE PROPER INSTRLLRTION. ! CERTIF'¢ 'TNFtT ::L: I RM FRMILIflR WITH THE REQUIREMENTLE, FOR ON-SITE '.E;E].',!ERS RND HELLS RS 2;ET FORTH E:'¢ THE HUNICIP~LtTV OF RNCNORRGE. 2: I !.,.!IL.L IN:BTRLL THE :BYS'TEM IN FIC:CORDFtNCE HtTH THE CODE~;. 2: I UNDER~;TRND TFIFfT THE ON-SITE E;Et.,.IER SYSiTEM MR? REQUIRE ENLRR(3EMENT IF' TNE RESIDENCE IS REidODEL. ED TO INCLUDE HORE THRN :2 BEDROOMS. V4. E) '"~'~ ~-%~, ~ SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchbrage, A)aska 99501 264-47;20 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: -T~7~.~' ~t~/~ j~j~;~J [~r~,l~j~,~ DATE PERFORMED: LEGAL DESCR,PT,ON: SLOPE SITE PLAN 1 5 6 7 8 I0 11 ~"~12 13 14 15 16 '17 18 19 20 COMMENTS WAS GROUND WATER /~0 SL ENCOUNTERED? O P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop z_ z.. /:30 ~o ~,u. z~' "/~ " '1~ " ~ ~o0 ,, ~I ~/~" ~]~" PERCOLATION RATE ~:~ (minutes/inch) , TEST RUN BETWEEN ¢ FT AND ~' V~, FT PERFORMED BY: ,/~/,'~-"~ '~'1~'~''~'~ 72-008 (6/79) DRILLING LOG Well Ow~e~ .:7~ ~t, ez,p~e~ .Use of Well i',o~tio~ (add~es~ off Tow~sKip, ~se, SeetJo~ if k~ow~; o~ distance main ~o8d Size of casin~ 6" Depth of Hole L~3 feet Cased to ~2.3 feet Static water level Screen ( ); Perforated .( . )i Describe screen or perforatio- 13~z,,p%'~mbex' lot ~" (K~X) (minute) for 1 Well pumpin~ of drawdown from static ft. ~8~b~"~:j_ (below) land surface. Finish of well (check one) open end ( :~-' ); hours with Date of WELL LOG penetrated, .Size of material, color and hardness MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHOR ITY APPROVAL FOR A SINGLE FAMILY DWELLING 020-413-05 HAA# GENERAL INFORMATION Complete'legal d~cription Lot 16, Block 7, Paradise Valley Location (site address or directions) 61 31 Austria Dr. Prope~y owner Terry & Karen Dannenbring Day phone Mailing address 6131 Austria Dr. Anchoraqe, Alaska Lending agency None at this time Day phone Mailin_g address 345-3660 99516 Agent None at this time Day phone Address Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: 3 ' TYPE OF WATER SUPPLY: Individual well XX Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: XX If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev, 1/91) Front MOA~21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Pinard Enqineerinq Address PO Bo~%.871 347 ~.. W~n~ I 1~; Engineer's signature ~ Y--~ Phone (907) 357-3647 Date 5/13/99 DHHS SIGNATURE ^pproved for 7-#/f bedrooms. Disapproved. Conditional approval for bedrooms, with th% following stipulations: Note: The well for this property meets existing State and Municipal Codes. There ar~ n~trmt~ nr~nt. Tt ~ ~,~ ~n~ periodic ~=~ ~ performed to insure the wells continued suitability. Current nitrate More information on nitrates is available from the On-site Services Program, DHHS, ~-~,~. Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-O~(Flev, 1,91) Back MOAii~l DEPARTMENT OF HEALTH & Environmental SerVices Division 825 L Street, Room 502 · Anchorages Alaska 99,501 · Health Authority APp Legal Description: Lot- 16. Bk 7. Paradise Vallev Parcel I.D.: 020-413-05 A. WELL DATA Well type ~ If A, B, or C, attachADEC letter. ADEC water system number Log present (Y/N) y Date completed 9/10/99 Total depth 123 ' Cased to 1 23 ' _ Casing height (above ground)~ Sanitary seal (Y/N). ¥ Wires properly protected (Y/N) FROM WELL LOG AT INSPECTION Date of test 9/10/82 3/25/99 Static water level 55 ' 18,2' Well production 3 g.p.m. 6.9 WATER'SAMPLE RESULTS: Coliform None Nitrate 8.68- mq/Z Other bacteria Date of sample: 4/29/99 ; Collected by: Pinard Engineering B. SEPTIC/HOLDING TANK DATA Date installed ._~ Tank size 1000 ~ Number of Compartments 2 CleanoUtS (Y/N) Foundation cleanout (Y/N) ¥ Depression (Y/N) 1~1 High water alarm (Y/N) Date of PUmping 3/25/99 Puml~er Isaacs Pumpinq Service C. ABSORPTIONFIELD DATA Date installed 4/29/99 Soil rating (g.F.--,~, '~ ~"~ c ' 2 ' Length 32 Width .5 Effective absorption area 576 sf - Monitoring Tube pre'sent (Y/N) ¥ Depression over fiel~ (WN) Date of adequacy test N/A · Resu ts (Pass/FaiI) For Fluid depth in absorption field before test(in.); g.p.m 188 System type Deep Trench I Pipe 9 ' Total dept~h 13 ' N bedrooms Immediately after gal. water addedl (in.): Fluid depth (ins) Minutes later: Absorption rate = g.p.d. Peroxide treatment (past 12 months) (Y/N) 72-026 (Rev. 3/96)* If yes, g ve date D. LIFT STATION Date installed N/A Manhole/Access (Y/N) High water alarm level at* Cycles tested E, SEPARATION DISTANCES Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line Size in gallons "Pump on" level at* *Datum SEPARATION DISTANCES FROM WELL ON LOT TO: 100'+ 100'+ 25'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation 1 ;2 ' Property line 1'0 ' + Water main/service line 1 0 ' + Surface water/drainage 1 00 ' + SE PARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation 1 0 ' + Property line 1 0 ' + Surface water 100' + Curtain drain N/A F. ENGINEER'S CERTIFICATION "Pump off" level at* On adjacent lots 1 00 ~ + On adjacent lots 1 00 ' + Public sewer manhole/cleanout N/A Lift station ~/A 10"+ Absorption field Wells on adjacent lots 96' (Waiver on Water main/service line 1 0 ' + Driveway, parking/vehicle storage area '5 ' + Wells on adjacent lots 1 00 ' + I certify that I have determined thru field inspections and r~ are in conformance with MOA HAA guidelines in effect on this date. Signature Engineer's Name Date ~ - ~,, . - . ,~. ~ ~ . ,view of Municipal r~j~." t~at th~e~le ~' .~. , .., Paul Pinard ~. ~....~ ~ file) HAA Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SiTE SEWER AND WATER FACILITY 264-4720 Application Date GENERAL INFORMATION (a) (b) (c) Legal D~escription (include lot, block, sub, division, section, tqwnship, Location (address or directions) Applicant Name"'~(EL¢ ¢ ~ ¢t-~('.~re-~c'~.~r~ ~TeY'E~hone:* Home aO L~:::) ..-- --!~:x~' Business Applicant Address ~' IoV~, ~5t-~,¢< ,'--~) ~-. ~-~,,,c.~,.,. ~- Applicant is (check one): Lending Institution []; Owner/builder ~'; Buyer []; Other [] (explain); (d) Lending Institution /"~!O(~(;t I.).~,~. '~, C¢('~i~ UCh~Oi~elephone Address (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: TYPE OF RESIDENCE Singie-Family~ Multi-Family [] Number of Bedrooms Other WATER SUPPLY individual Well'~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environ mental Conservation attesting to the legality and status. SEWAGE DISPOSAL ., Onsite ~ Public [] Community [] Holding Ta'nk [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11/84) ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the numbe~ of bedrooms and type of structure indicated herein~ I further verify that based on the information obtained from the Muni~!'pality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disp, bsal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ~a-~Le,~- ~,. ~:~c,.,a-~e:..'5 Telephone i~z{(> ~ Address Engineer's Seal DHEP APPROVAL Approved for ./'/~'~'-~"~ L~,~l~edrooms by Approved ' )~' ' Disapproved Conditional Terms of Conditional APproval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 264-4720 Legal Description: e [(~ I~L~ "'/ MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH ~ ENVIRONMENTAL PROTECTION 1986 WELL DATA Well Classification Wel Log Present (Y/N) Total Depth ~-=,~ Cased to Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding -ank on Lot If A. B, C, D.E.C. Approved (Y/N) Date Completed q-lO- ~. Yield t,~.~ Depth of Grouting Pump Set At c~^~K~,n~- ~;~,,~1,'~ .4* Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) , On Adjoining Lots To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line Cleanout/Manhole Water Sample Collected by Water Sample Test Results Comments ; On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Serwce Line on Lot , Date B. SEPTIC/HOLDING TANK DATA Date Installed Standpipes (Y/N) ~ Air-tight Caps (Y/N) Depression over Tank (Y/N) i'~ Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: Size 1o~ No. of Compartments ~ Foundation Cleanout (Y/N) '%// Date Last Pumped t~- ; for Temporary Holding Tank Permit (Y/N) To Water-Supply Well To Property Line To Water Main/Service Line Course -- To Building Foundation To Disposal Field To Stream. Pond, Lake. or Major Drainage Comments Page 1 of 2 72-026(11/84~ C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Type of System Design Length of Field ~ Depth of Field 12. Gravel Bed Thickness ~, Standpipes Present (Y/N) Date of Last Adequacy Test Y 7- zz -84, Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well tOO To Building Foundation ~ To Property Line t.~ To Existing or Abandoned System on Lot ~ ; On Adjoining Lots t (JO-f- To Water Main/Service Line '--' To Cutbank (if present) To Stream/Pond/Lake/or Major Drainage Course "'"- To Driveway, Parking Area, or Vehicle Storage Area Comments 0 '", -- s u D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have cJ3ecked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed ~t"Y.4~ lt~ Date CO m pa ny _l~Z~..~ ~.~ ~ MOA No. ~'T'~'-2.~-~ Receipt No. J~ J "'~ ~ [ Date of Payment Amount: $ Page 2 of 2 72-026 (11/84) Engineer's Seal BARTER & ASSOCIATES 10461 HAMPTON DRIVE, ANCHORAGE, ALASKA 99516 PHONE (907) 346-1170, TONY BARTER, P.E. July 22, 1986 To: Mr. Terry Dannenbring 6131 Austria Anchorage, Alaska 99516 Ref: Lot 16, Block 7 Paradise Valley Subdivision Dear Mr. Dannenbring, At your request, I performed an Adequacy Test on the existing septic system for the three bedroom residence at the above referenced location. According to the Greater Anchorage Area Borough's Inspection report for installation of On-Site Sewage Disposal Systems at this location (8/26/82), your system consists of a I000 gallon steel tank and 73 lineal feet of trench. Upon arriving at the property on July 22, 1986, I observed the septic system and recorded the static water levels. Water was then introduced to the system at approximately 7.5 gallons per minute. The sump at the west end of the trench was monitored for the test. The water levels were periodically measured and recorded with respect to time during the filling and subsequent absorbing period. The absorption rate was extrapolated according to Dr. leroy Reids paper, "In Situ Testing of On-Site Sewer Systems," September, 1982. The septic system was in normal use before and after the test. Water was introduced to the system at 7.5 gallons per minute. I futher certify that the well sustained a yield of 7.5 gpm for a period of time in excess of three hours without showing any signs of stress. On the date tested, this septic system meets the Municipality of Anchorage sewer and water requirements for a.three~ bedroom residence. Sincerely, Tono W. Barter. P.E. - APPLIE'--' IT FILLS OUT UppER HAl.' ",ONLY .eroperty,,Own~ ~ ~. ~ ~ . · Phone Buyer ~ ~ g Address Zip Code Phone Realty Co. & A.nt ~/~ Address ZiP Code ~ LegalDescription ~~ ~ ~/~/~O~ ~ ~ ~T J~ Type of Resi~nce ~ingle Family ~ Multiple Family No. of Bedrooms ~ ~ Other CSupply ndividual A~ACH WELL LOG. A w~l Icg is required for all wells drilled since June 1975, ommunity For wells drilled prior to that date, give well depth (attach Icg if available). ~ Public Utility Sewer Disposal ~lndividual Year Individual Installed: ~ ~ ~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED, Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector MUNICIPALITY OF ANCHUkAGE Field Notes: J'¢-- ~) b DFr~T C'~ I'= ENVIRO~, _t .;cC 2 0 1982 ECE! ED ( .~.~PPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received ~ ~ .~..~ ~ ~ ~ Well to Tank Septic Tank Size j 72.023 (3182)