ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211439 PID Number: 020-413-37
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
GAYLE KNEPPER & DONALD CASSAS
ABSORPTION FIELD - NONE
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
5931 ROMANIA DR., ANCHORAGE, AK 99516
❑ Other
Phone
Number o f Bedrooms
Soil Rating
Total depth from original grade
3
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
PARADISE VALLEY 8 17
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
FtZ
Ft.
Well
__
__
__
100'
0_°,
°
TANK [I Septic ElS.T.E.P. ® Holding El Other
�J
Manufacturer
ANCHORAGE TANK
Capacity
2 TANKS OF 1500 Gal.
Surface Water
--
--
--
100'+
Material
POLY -COATED STEEL
Number of compartments
1
Lot Line
--
__
-_
5'+
NA
Foundation
--
10'+
I
LIFT STATION — HOLDING TANK
Manufacturer
Capacity
Gal.
Remarks Holes cut into baffles. Alarm set in 2"d tank.
Tanks anchored - no groundwater observed at install.
Alarm location
LIVING ROOM
Electrical installed by
EXISTING
Installer MIKE ANDERSON
PIPE MATERIAL House to tank 3034 Tank to 3034
drainfield
Drainfield CO/MT 3034
Inspector FWCS & MNA
BENCH MARK (Assumed elevation) 100 ft
Inspection 1St 12/23/21 2nd 12/27/21
Location and description
3`d 12/27121 41h
TOP OF MANHOLE
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
•
Conditional Approval: Date
.t'��
' " " "' o " " " •
Septic System
Approved /�j�
• r
Curtis Huffman ,a0�
��
%�� �z� 13120.ZZ
�%Date /��jF�•
���• CE128991,+
. 12/30/21 . •
AMW
�l FQ'°ROFESSIO�� ..�
Note: this approval does not include well permit requirements.
��� �ESSO'�`
kRCV uunjz/ 1 O)
PID: 020-413-37 PERMIT: OSP211439
-�lz
h �
)
�A
t
A—C=58.9'
B—C=35,9'
A—D=63.2'
B—D=42.9'
A—E=66.2'
B—E=50.1'
A—F=72.2'
B—F=62.0'
0.
G
PD�W A
!o -A
LOT 17 a�
BLK 8 �� B 2'X5.5
FP CANT
STAKED 100'
WELL RADII
& SURFACE
WATER SETBACK
PRIOR TO
CONST.
r
Fa
1,500 -GALLON
EPDXY-STEEL
TANK
D
DCO
SEPTIC SECTION
SCALE: NTS
/ DECOMMISSIONED EXISTING
HOLDING TANKS &
INSTALLED 2 NEW
1500 -GAL POLY -COATED !
STEEL SEPTIC TANKS V
WITH BAFFLES CUT. �OGj
CO
tx
(*BM)
1,500 -GALLON
EPDXY STEEL
TANK
W/ FLOAT
ALARM
'rJ
,70
LOT 16
18' SQUARE HOLES CUT IN
BAFFLES & TANKS ANCHORED.
USED EXISTING HARING &
ALARM. ALARM LOCATED IN
LIVING ROMM CLOSET.
T
PARADISE VALLEY BLOCK 8, LOT 17 SUPPORT, SERVICES: - AV OF AZ
PREPARED FOR: AV 4, '
GAYLE KNEPPER & DONALD CASSAS Af TH
5931 ROMANIA DRIVE
FW-NCS
�* 9
ANCHORAGE, AK 99516
FIRST WATER CONSULTING DATE: 12/30/21 I` rtis Huffman /
SURVEY: JLS � CE 128991 `�
13030 SUES WAY DRAWN: FWCS 11 12/21/21G�
ANCHORAGE, AK 99516 SCALE: 1" = 30' \ '°�ss>o1zAti
907-350-9566 FirstWaterAK®gmail.com ��
�F
ANCHORAGE RECORDING DISTRICT, ALASKA
AS -BUILT OF:
PARADISE VALLEY SUBDIVISION
LOT 17 BLOCK 8 PLAT 87-16
SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a
physical survey of this property as shown on this drawing and that the
improvements situated hereon are within the property lines and no
enchroachments exist other than noted. Under no circumstance should
any information on this drawing be used for construction of fences,
structures, improvements, or for establishing boundary lines.
EXCLUSION NOTES: It is the owners responsibility to detennine
the existence of any easements, covenants, or restrictions which
do not appear on. the recorded subdivision plat.
WORK ORDER NUMBER: DATE: SCALE.—MAIL
DEC 29, 2021 1 "=30' schullerOok.net
21-142-2 DRAWN BY: CHECKED BY GRID NWASER: BOOK/PAGE:
JLS SW3538 220111
�s
��s 0s
oJqj 4/
kk
Q = FND 5/8" REBAR.
AW F NZ4� � U.
AXV
AV
A.
TH
0 AV , ..-LJ
FA
* #j
FAP
..............................
° ••.JQH1V L. SCHULLER.� a / It
LS -10408
i .,..ar.'
°,. ' • , �� / 1831 'Talkeetna Street
6 'AW Anchorage, ,Alaska 99508
1 Ar oo
° fe Q� L ate. (907) 227 1455 ,office
�'�', SSlO�,,''►~` {907) 274--4992 fax
Jan 20, 2022
Municipalities of Anchorage
Departments of Health and Human Services
P.O. Box 196650
Anchorage, Alaska 99519-6650
Fax 249-7847
Re: Hold Tank Testing
Legal: PARADISE VALLEY BLK 8 LT 17
To Whom it may concern:
This is my report on the testing of the two steel holding tank s installed on the above
referenced lot. Both tanks were filled by Around the Clock Pumping to test for
leaks. After filling both tanks with more than 3000 gallons of waste, we waited to
verify that they held. After a 30 minute test both tanks were pumped out and are now
ready for normal operation, no leakage was observed.
Sincerely
Michael N. Anderson, P.E.
4661 Natrona
Anch, Ak 99516
Ph 727-8864
December 9, 2021
Municipality of Anchorage
Development Services Division
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska 99507
Subject: Structural Analysis of 1500 Gallon, 10-Gauge, Holding Tank
To: Whom It May Concern,
An analysis was performed for a 1,500 gallon, 10-gauge, buried septic holding tank per my own design. This
approval allows a maximum 4-ft burial depth with a 2-ft water table (4-ft of soil with 2-ft of water allowed over the
top of the tank). The tank dimensions are 64-in diameter, 10-ft long, with one internal baffle. Slight compaction
with a granular bedding material is assumed. The tank will be pressure tested in the field by filling the tank two
feet above the tank/riser joint to verify the joint is water tight. Bentonite chips will also be placed around the joint
to keep the tank watertight. Standard silicon sealant will also on all surfaces during assembly.
The tank was analyzed using two approaches. These approaches were compared and the most conservative is
used as a limit state. The first approach is based on research conducted by the Steel Tank Institute (STI) reported
in a paper titled “Performance Testing of Underground Storage Tank Against Buckling” (attached with
calculations). That research confirms a buried steel tank can be analyzed using the AWWA M11 simplified
approach for buried pipe. This approach accounts for soil bridging action which tends to reduce force on the tank
wall and also confines the tank wall to resist buckling. Maximum allowable loads were developed using the
AWWA M11 criteria set forth in chapter 6 based on the STI paper recommendations. The second approach is a
finite element model of the tank. The tank was modeled using finite elements with the SAP2000 analysis package
to compare the results to the AWW A M11 approach. The model used thin shell elements matching the 10 gage
wall thickness and the tank dimensions 64” diameter and 10’-0” long with an internal perforated (18”) baffle, see
attached drawing. The baffle was included in the tank analysis. The loading and restraints used were derived
from the AWWA M11 methodology. Soil loading was applied to the top quadrant of the tank assuming a heavy
granular fill (130 pcf). Restraints were applied to the bottom quadrant of the tank. The restraint assumes a Winkler
foundation model with soil springs equivalent to a granular bedding profile (100 pci modulus of subgrade
reaction). The analysis assumes the tank is empty with no internal hydrostatic pressure to offset external soil
pressure.
The limiting load per AWWA M11 is based on buckling pressure and the limiting load from the finite element
model is based on yield stress. The lesser of these two with appropriate factors of safety is considered the
maximum allowable load.
The maximum load per AWWA M11 is 670-psf and the actual load based on the burial depth with water table is
645-psf. The maximum allowable steel stress is 29.9-ksi and the maximum stress from the finite element model
based on the 645-psf loading is 24.0-ksi. Each approach confirms the tank is adequate under the burial conditions
set forth above.
Attached are the calculations, analysis results, and reference materials. If there are any questions, please feel
free to contact me.
Sincerely,
Michael N. Anderson, P.E.
4661 Natrona Street
Anchorage, Alaska 99516
(907) 345-3377
DESIGNED:DRAWN:DATE:CHECKED:SHEET1500 GALLON STEEL SEPTIC HOLDING TANK
Anchorage, Alaska
4661 NATRONA AVE
ANCHORAGE, ALASKA 99516
(907) 727-8864 / FAX: (907) 345-1391
THE MUNICIPALITY OF
ANCHORAGE1 MICHAEL N. ANDERSON, P.E.
1
Carroll, Rebecca M.
From:Noffsinger, Ross D.
Sent:Friday, December 10, 2021 2:23 PM
To:Carroll, Rebecca M.
Subject:FW: tank analysis
Attachments:1500 Holding Tank Analysis Letter.pdf; HOLD TANK DESIGN.PDF
Follow Up Flag:Follow up
Flag Status:Flagged
I spoke to Mike. He is requesting a one‐time approval for a specific project. I told him this is acceptable for that
project. In order for the tank to get a general approval, Greer needs to demonstrate a water tight manway
connection.
Ross Noffsinger, PE
Engineering Services Manager
Development Services Department
Municipality of Anchorage
343‐8309
From: Mike Anderson <mnanderson58@gmail.com>
Sent: Friday, December 10, 2021 11:49 AM
To: Carroll, Rebecca M. <rebecca.carroll@anchorageak.gov>
Cc: 'Sam Arias' <sam@anchoragetank.com>; Noffsinger, Ross D. <ross.noffsinger@anchorageak.gov>
Subject: RE: tank analysis
[EXTERNAL EMAIL]
Ross,
See below for my comments and revisions… in red..
M
From: Carroll, Rebecca M. [mailto:rebecca.carroll@anchorageak.gov]
Sent: Friday, November 19, 2021 12:05 PM
To: Mike Anderson
Cc: 'Sam Arias'; Noffsinger, Ross D.
Subject: RE: tank analysis
Mike,
We have the following comments:
1. Please provide details for the connection between the tank and manway riser and explain how it will be guaranteed
that the connections are water‐tight. Bentonite chips will be added around the tank/riser joint and a water test (fill
the tank 24” above the joint) will be done to verify joint is watertight. All of the tanks have bolts connecting the
flange to the riser. Silicone glue is also used between all surfaces.
2. In your request letter, you describe the tank as having an internal baffle. Please clarify that the baffle has an 18”
diameter hole in it and confirm/state that your structural calculations take the hole into account (or that the
calculations assume no baffle). Baffle hole has been revised in both views of the tank, see dwgs.
2
Thank you,
Becca Carroll
Onsite Water and Wastewater
Municipality of Anchorage
343-7908
From: Mike Anderson <mnanderson58@gmail.com>
Sent: Wednesday, November 17, 2021 8:19 AM
To: Noffsinger, Ross D. <ross.noffsinger@anchorageak.gov>; Carroll, Rebecca M. <rebecca.carroll@anchorageak.gov>
Cc: 'Sam Arias' <sam@anchoragetank.com>
Subject: tank analysis
[EXTERNAL EMAIL]
Ross, Becca,
Attached is the 1500 gallon tank analysis for a holding tank installation…we have not modified the tank just checked to see if
the baffle can be perforated for a hold tank application…
Please call to discuss…Anch tank is aware of this work…
M
MUNICIPALITY OF ANCHOR -AGE
On -Sita water & Wastewater Program
P4 Baas 190050 4700 Elrnorr} Rmd
Anchorage, AlasKs gMig-GGG9 flwrtie: (907 343-7904 Fara_ M7) 3 997
On -Site Wastewater Disposal System Permit
Permit NurnW; O P 1143()
Wank Type. SaptirTank Upgrade
Tux Codc Nurnbcr; 02041837000
Site Legal Address, PARADISE VALLEY SIX 8 LT 17 G,3538
Site Mailing Address; 5931 ROMANIA DR, Anchorage
Owner; KNIEPPER GAYLE DENISE &
Dei i g n Eng ineer, FIRST WATE R CONSULTING
Th 19 pe rrn 11 is fo r the constru clop of,
Effective Date:
Expiration nate:
Lot Size In Sq Ft,
Total Bedrooms,
L L
ct�;�i'trntn�
10119t2021
10119M22
21014
❑ Disposal'Field ❑ Septic Tank Q Molding Tank ❑ RNvy ❑ Prlvat-e weir El Water Storage
All construction shall be in accordance with,
1, The altached approved design.
2. All requlrernernks specified in Arron ga Muni -Opal Code Chapters 15.65 and 15,55 and the State of Alaska
Wastewater Disposal Regulatlons (1$AAC72) and Drinking Water Regulatlons (18AAC80)
3. The wastewater a❑d$ re-quir$e inspoGtiona -during the installation. Thcr engine rr aall nofify tho Uev lGDpmcnt
Services Department per AMC 15.65. Provide notification by calling (947) 343-7994 (24f7)_
4_ From 00*ber 15 to April 15, a subSurFaoe snit :Nb.5erpWn system u rider construction du ring freezing weather
shall be eithay.
a_ Open ad and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
ReoeNed By;
Issued By:
10/1912021
Date:
Data,
3
!��/�1UHMPA-UTY OF '\ HCHO AGE
r"► Vii; _L�'`
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 020-413-37
Property owner(s) GAYLE KNEPPER & DONALD CASSAS Day phone
Mailing address 5931 ROMANIA DRIVE, ANCHORAGE, AK 99516
Site address 5931 ROMANIA DRIVE, ANCHORAGE, AK 99516
Legal description (Sub'd., Block & Lot) PARADISE VALLEY 138, L17
Legal description (Township, Range & Section)
Lot Size 21014 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) El
(w/wo ADU)
Septic Tank
❑
Upgrade 17 1
Duplex (D) ElRenewal
Holding Tank
0
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES
A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
nature or property owner or autnorizeci agent)
Permit/Rush Fees: $2.Z 5 Waiver Fees:
Date of Payment: /0 A I Date of Payment:
Receipt Number: Receipt Number:
Permit No. 05P Z l 1 Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
October 11, 2021
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: HOLDING TANK UPGRADE PERMIT
LEGAL: PARADISE VALLEY BLOCK 8, LOT 17
The owner has requested that we obtain a septic permit to upgrade the existing aged steel holding
tanks on the above referenced lot. We propose to install two 1500-gallon HDPE tanks in series
with an alarm to serve the existing 3-bedroom residence. The lot and area are served by private
water. The design will not impact any of the neighboring properties. Please contact us if you
have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211439, Rebecca Carroll, 10/19/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211439, Rebecca Carroll, 10/19/21
DEPARTMENT OF HEALTH AND HUMAN SERVICES
' Environmental Health Division
825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Name DISTANCES
Fannie Mae ~.. ~"~'~--......~ T 0 SEPTIC HOLDING
~ddressrnum ~ TANK TANK WELL
3201 'C' Street, Suite 505
Phone(s)561_0828 Permit880230N°' N o.ool..;, Bedrooms WELL 100 ' 94~
LEGAL DESCRIPTION LDT LINE 24 ' 48¢ 15
Lot J Block Subdivision
17I 8 Parad4 ~ Vnl 1 ~y FOUNDATION 17i 28~ 34
Township, Range, Section -
'~ ?~' N; '-'~ :' ~;" ~;' "'~' ~"~" ....... :?:~;4~.? ~-!~: %.-, :.r ~.~:. :;-.-¢, ........... dnveway," Water'':' ~bod,es, .......... etb.)' ' ..... ' ............ ~---t .....
TANKS U
~ SEPTIC ~ HOLDING
~anulacturer Capacity m gallocs
Alaska Tank 3,000
Material No. ol Compadments
Steel septic-2, holding-1 ~.~
~TRENCH ~ BED ~ W. DRAIN ~ OTHER u~
~th ~o p~pe bottom from 7oral depth from origina~ grade /~
onginal grade FT FT
/
FT FT~
Gravel length FT Gravel width FT /
area Distance between lines /
Total
Sg FT FT -
Pipe material/ / '
Numberol, .... Sollrabng ~ ~ ~, ~
g PRIVATE g OTHER (Identify).m~.
Classdicat~on (A,B,C) Total Depth Cased to ~ .~ ~ ~ /
individual 328 FT ~ ~f ;~. ~ ~ /
Inslaltel Date Installed: ~ ~
/
REMARKS: % '~
Holding Tank System consists of the ~
exlstin~ 1~000 qallon, 2-compartment I~spectioRs Pedormed by: ~ . ~[,.,~' (~-{~" ~.%...s~'A ~" '%".~
septic tank as well as a 2,000 qallon pa~: ~'-~
tank ' Nov; 30, Dec 1, 198~
steel holdin~
Municipal a~d Slate guidelines in eJlect a~ Ibis date:
Health Depa.ment Approvak 4'__ --r ' --~ Ua'~: ~
72 013 (3/85)
L,o'L J,,,.egal: SLd:~d:i,v:i. sicH"l~ PARADIS[ii: VAL,,L,.EY Lot: 17
Sec t i on: I :1. 'J (:t~i"i sh i p: 1 i N Range:
Lo'L Size 287~:~() (sq. J"L,, (::)i' att'es)
~"~;.'~;,{ Bedr'ooms:~ ]his Per, mit: :3 'f'o'Lal Capacity:
Blocl-::: 8
.... -~..- v' '.. · :i. ze:; "' O()C) Cla].lof'H~, A h:i,c:lh water' a].aPm mLts'J:, be
I'-!i;i !).i. NG t~-.,,11'..¢, .i.I ~ Il.un Tartl-:: S ,:::.~ ....
'~ ::u~ I,:: .::; .~ ,: 0 ~' ee'L P {~ qL~ :J, 1" (,;,:,s ;i. r)~i~;L.( ]. ~'~., i c)i"'l (3v(~~ !" '~. ~tl'l k.
:I:NSTAI..,L PER ENG:i:NEERS A'r'TP, C.:HE.D PI...ANS. F'ERMt'F ISSLJED F(3R "r'PIE
LC X ]; ~;'t' ]: l'q~:.J J, i.,.,d:: ¢)ROOM S :1: NGLE FrAM Z L..Y RES I DENCE ON!..Y ~lqD E X F:' :t: RES
;1.2/:S:i./~8. PROVIDE SOILS LOG W!'t"H AS.,.,.BLIII./I". NO'f'~FY DF.IHS F:'RIIJR
FEi ,ILN~:iF;'IEC"I"IEIN BY ENG]iNIEEI;:~.
Tom Fink,
May~r
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
December 5, 1988
Richard C. Button, P.E.
Engineering Evaluation &
Investigation Services, Inc.
200 West 34th, Box 267
Anchorage, Alaska 99503
Subject: Lot 17 BLock 8 Paradise Valley Waiver Request
Waiver Request 9WR88-070, Permit #880230
Your request for waiver of the required 75 foot separation
of a holding tank to surface water, Romania drainage, has
been approved. The approved separation distance is 50 feet.
This waiver approval applies to the new holding tank to be
installed as per Permit #880230. Any future upgrade will require
all separation distances be met or another approval from this
department°
Sincerely,
Daniel J.'Roth
Civil Engineer
On-site Services
DJR/ljw
ENGINEERING EVALUATION
&
INVESTIGATION SERVICES, INC.
MUNICIPALITY OF ANCHORAGE
ENVIRONMEN~L SERVICES DIVISION
November 18, 1988
RECEIVED
Hr. Ban Roth
Hunicipality o¢ Anchorage
Department o¢ Health and Human Services
Division o¢ Environmental Services
825 "L" Street
Anchorage, Alaska 99501
Document No:
Subject:
8277HC3o002
Romania Drive A/W/S, Lot 17, 81k 8, Paradise
Valley Subdivision - Waiver o¢ Horizontal
Bistance between septic tank/proposed
holding tank and Romania Drive ditch stream
Dear Hr, Roth:
We are requesting that you review the attached site plan ¢or
consideration in granting a horizontal distance waiver down
to a 50-¢oot separation between the proposed holding tank
installation on Lot 17 and the ADEC classi¢ied stream at the
ditch line o¢ Romania Drive.
The holding tank system shall be leak proo¢ and installed in
con¢ormance to the Department o¢ Health and Human Services
Wasteuater Disposal Regulations. The existing 1,000-gallon
septic tank (installed new 11/84) will become part o¢ the
holding system. We will veri~y the integrity o¢ the tank by
exposing the top and side inlets and top manholes to ensure
that all connections are leak proo¢. Calder type couplings
and Ram Neck sealant will be used Cot any de¢iciencies.
The addition o¢ the 2,000 gallon holding tank is proposed to
be linked to the outCall end o¢ the septic tank by an 8-f'oot
section o¢ PVC ASTH 3034,
200 West 34th, Box 267 o Anchorage, Alaska 99503 · (907) 274-7611
Dan Roth
November 18,
Page two
1988
you have any questions, please call.
Sincepely,
ENGINEERING EVALUATION AND INVESTIGATION SERVICES, INC,
A1 an M. Harala
Sta¢¢ Engineer'
APPROVED:
ichar~ C. Button,
Principal
AMH:lwh
8277HC3,002
attachment
200 West 34th, Box 267 · Anchorage, Alaska 99503 · (907) 274-7611
'ENGINEERING EVALUATION
and
, INVESTIGATION SERVICES
200 West 3a, th, #267
ANCHORAGE, ALASKA 99503
SCAt~ I/f~
October 10, 1988
Municipality o¢ Anchorage
Department o¢ Health
and Human Services
Environmental Quality Services
825 "L" Street
Anchorage, Alaska 99501
Attention: Onsite Environmental Services
Document No:
Subject:
8203PC.002
Romania Drive A/W/S
Dear Sir:
Our recent adequacy testing o¢ the on-site wasteuater disposal
system existing on Lot 17, 8LK 8, Paradise Valley Subdivision
Called due to high ground water and/or impervious soil conditions
in the area. The only alternative we see is to resort to a
holding tank system. This would require that a 2,000 gallon
holding tank be placed in series with the existing 1,000 gallon
septic tank to allow ¢ora 3,000 gallon capacity.
We are requesting that your department issue a permit, pursuant
to Chapter 15.65.090 o¢ the wastewater regulations, so that ~ork
may commence on the project.
Attached is an as-built of the property and proposed holding tank
placement.
Sincerel y~~
8ruce D. Patterson, P.E.
BDP:luh
attachment
ENGINEERING EVALUA1 mON
&
INVESTIGATION SERVICES, INC.
October 6, ~988
Fannie Hoe
3201C Street, Suite 505
Anchorage, Alaska 99503
Attn:
Document No:
Subject:
Nancy Gilbert
8203PC3.001
Romania Drive A/W/S
Dear Ms. Gilbert:
We ha'~'e per?ormed' an as-Built, a uell and. septic system as-built.
on Lot 18, Block 8, Paradise Valley Subdivision. A copy of the
as-built is attached. As you can see, the neighbor's (lot 16)
?ence encroaches onto Lot 17.
The uell test proved satisfactory. The drain¢ield, houever, does
not meet the Municipality of Anchorage requirements. When I
visit'ed the site, the drain{ield uas {looded with the water level
being.approximately 18 inches belou ground level. The house and
drain~'ield are rated ?or three bedrooms. It is my understanding
that at the present time, the house is occupied by only two
people, (equivalent to 1 bedroom). When I performed the adequacy
test, the water level rose to less than 1 ?oot below the ground
surface. My' inspection ?ollowed a period of heavy rain.
Although the drainfield will accept the_required amount o? uater
to support a three bedroom house the drainfield does ~ot meet
'']Municipal requirements because the uater level in the ?ie'ld is so
high. The effluent does not flou down through the bottom o? the
field. Instead, some of it flous horizontally through the' soil,
just belou the ground surface.
This situation exists with only two people using the system and
would be much more severe if the house were occupied by the six
people the system was designed for.
The only alternative I see is to install a holding tank to hold
the wastewater and periodic pumping. A three bedroom house will
require 2000 gallons of storage, This wil.1 cost approximately
$3,400.00. The existing I000 gallon septic tank can be used as
part a? the holding tank.
200 West 34th, Box 267 · Anchorage, Alaska 99503 o (907) 274-7611
Romania Drive A/W/S
October 6, 1988
Page 2
As per our conversation this morning, ue uill prepare
application ~or a permit and solicit bids ~or a 2000
holding tank installed in series with the septic tank to
3000 gallons o? storage.
I? you have questions, please call Allan at 274-7611.
Sincerely,
Bruce .D. Patterson, P.E.
BDP/nb
our
gallon
provide
200 West 34th, Box 267 · Anchorage, Alaska 99503 · (907) 274-7611
! hereby certify that !
have surveyed the property
described on this plat and
the improvements situated
lhereon are located as
shoun on this plat,
Dat,d _9_./_¢,_¢-'- .....
LEGEND
Lot Corners
Foundation
'Drainage Arrous
NOTES ,
i. It shall be the responsibility of the builder or Donor to
verify that building location shoun meets all subdivision
covenants and zoning ordinances.
2o It is the responsibility of the builder to verify all
elevations uith respect to all utilities & drainage.
3. This plat represents the parcel of property described belou
taken Crom the recorded plat describing that parcel. Instruments
recorded prior tn or after the filing oF the recorded plat are
not shuun un this plat.
4.' 'The information on this plat' is far the use of lending
institutions specifically to shou any conflicts betueen existing
structures and platted lot lines dr easements, the plat is not to
be used for positioning additional structures or fences,
'-'
~EIS CONSULTING ENGINEERS,.'INC.;
200 West 34th,' Box 267
Anchorage, Alaska 99503 (907) 274-7611
Project ~ 61qO Date ~.~
'~'// WATER WELL RECORD
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of Geological ~ Geophysical Surveys
Drilling Permit No.
LOCATION OF WELL (Please complete either la~ lb or Ic.) A.D.L. No.
~'~l[Bordugh Subdivision flat BlockI I~.I I/4qtrs- Section No. TownshiPN0 Range EE~ Meridian
Ic.JJDISTANCE AND DIRECTION FROM ROAD INTERSECTIONS 3, OWNER OF WELL:
WELL LOG Feet Below 4. WELL DEPTH: (final) 5. DATE OF COMPLETION
Material Type Top Bottom
' ~' , ,~ ~' ,~ 8, CASING~ ~ Threaded ~ Welded
diam. in. fo~ft. Depth Sfickup ~;'* ~ ft.
9. FINISH OF WELL:
Backfilling Grovel pack
I0, STATIC WATER LEVEL:
~Above or ~ Gelow land surface Date
I~. PUMPING LEVEL below land surfooe and YIELD
~ ft. after hrs. pum~ng g.p.m.
_. i~ ~~ I~.GROUTING We,' Grouted: ~ YeS ~ No
-- ~AN~~ '- Material: ~Ne., Cement ~ Other:
~' h IS, PUMP: (if available) HP
~--- ~,~, ~--~( ~ Length of Drop ,~pe ft. copaclty g.p.m.
15. Woter Temperature ~ ~ F ~ C
MUNICIPALITY OF ANCHORAGE
Development Services Department `_ &}-r Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 020-413-37
1. GENERAL INFORMATION
Expiration Date: 0a 1 I I a N
Complete legal description PARADISE VALLEY BLOCK 8, LOT 17
Location (site address) 5931 ROMANIA DRIVE, ANCHORAGE, AK 99516
Current property owner(s) GALE D. KNEPPER & DONALD B. CASSAS Day phone
Mailing address
Real estate agent
5931 ROMANIA DRIVE, ANCHORAGE, AK 99516
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
®
Private Septic
❑
Water Storage
❑
Holding Tank
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 550
Date of Payment 12- 8 00,01
Receipt Number �� so 3 3
COSA# 03C a 11701 —re'�ssuJ
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE, AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 7/6/2022
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting & FWCS
6. DSD/SIGNATURE
V System #1 Approved for
System #2 Approved for
Disapproved
Conditional approval for
S bedrooms
bedrooms
. ....•.*
.. .. .... .......:
Curtis Huffman
F CE 128991 . •�`���
�,•0Z/06/2Q2s' \
�
1,PROF
iF,ES���
SO
bedrooms, with the following stipulations:
WATER AND
By:/ Original Certificate Date: 1 1 oda
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory is
Septic System Advisory Arsenic Advisory
Well Flow Advisory X Other
COSA Checklist
Legal Description: PARADISE VALLEY BLOCK 8, LO 17 Parcel ID: 020-413-37
If more than 1 septic system on lot: COSA Checklist #
of
Structure served by this system
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 11/8/1984
Total depth 328 ft
Cased to 21 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 8/9/2021
Static water level at beginning of test 41 ft.
Well production at time of test 0.67 gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 7.24 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date of Sample 6/8/22 & 8/30/21 (ARSENIC)
Comments
B. TANK DATA
Age of tank(s) NEW years
Tank type/material HOLDING TANKS / STEEL
Measured operating fluid level in septic tank
Standpipes/foundation cleanout per record drawing
Date of pumping
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field
Monitor tubes go to bottom of effective. If not, state
depth into effective
Code-required soil cover over field
System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Adequacy test date
Results Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
Comments/Deficiencies:.
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100’
Yes if No
ft
Neighboring Tank > 100’ Yes if No *75+ ft
Absorption Field on Lot > 100’ Yes if No NA ft
Neighboring Absorption Fields > 100’
Yes if No
ft
Community Sewer Main > 75’ Yes if No
ft
Community Sewer Manhole/Cleanout > 100’
Yes if No
ft
Private Sewer/Septic Line > 25’ Yes if No
ft
Holding Tank > 100’ Yes if No
ft
Animal Containment > 50’ Yes if No
ft
Manure/Animal Excreta Storage > 100’
Yes if No
ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Property Line > 5’ Yes if No
ft
Absorption Field > 5’ Yes if No NA ft
Water Main > 10’ Yes if No
ft
Water Service Line > 10’ Yes if No
ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No
ft
Community Wells > 200’ Yes if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10’ Yes if No
ft
Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No
ft
Water Service Line > 10’ Yes if No
ft
Surface Water > 100’ Yes if No
ft
If absorption field is under driveway comment below
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No
F. ENGINEER’S COMMENTS
*SURVEYOR MEASURED 107’ TO CLOSEST VISIBLE LOT 18 STANDPIPE TO LOT 17 WELL. WELL IS 75-100’+
TO HOLDING TANKS ON LOT 18 & MET CODE AT TIME OF INSTALLATION.
G. ENGINEER’S CERTIFICATION
I certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
7/6/22
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT 907‐343‐7904
On‐Site Water and Wastewater Section Fax: 343‐7997
www.muni.org/onsite
Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org
Nitrate Advisory
Certificate of On‐Site Systems Approval # OSC211701
Subdivision: Paradise Valley, Block: 8, Lot: 17
A water sample revealed a nitrate concentration of 7.24 milligrams per liter (mg/L).
The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Since nitrates are known to slowly increase, we recommend
you monitor the water quality. Please see the attached “Nitrate Fact Sheet” for
important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On‐Site
Systems Approval.
Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org
Nitrate Fact Sheet
From Northern Testing Laboratories, Inc.
Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate
is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.
SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of
ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the
oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners,
food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil.
TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is
associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of
young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood
stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry
oxygen. For this reason, methemoglobinemia is referred to as “blue baby” disease. The EPA limits the
concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered
from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.
TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home
water treatment systems such as softening or iron filtration does not readily remove nitrate. The best
method for limiting nitrate in well water is source control. This can include avoiding overdosing of
fertilizer near the well and maintaining good separation distances between septic tank leach fields and
the well. A special anion exchange filter that contains a medi a with a strong affinity for negatively charged
ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.
TESTING: Nitrate analysis is usually done by one of the several “wet chemical” methods using a
spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect
the activity of nitrate in water. This laboratory uses several different wet chemical methods approved
under the public water supply laboratory certification program. They also have test kits available, which
the laboratory uses to perform an inexpensive “screening test”, and with which the homeowner can
monitor the change in nitrate levels from their well. They recommend comparing the test kit results
against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend
using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.
Received Date/Time 06/09/2022 13:41
06/08/2022 15:20Collected Date/Time
1222894001
Matrix
SGS Ref.#
Client Sample ID Spigot
Client Name
Project Name/#
Printed Date/Time 06/23/2022 13:14First Water Consulting Services (FWCS)
Technical Director Stephen C. Ede
5931 Romania
Drinking Water
Sample Remarks:
Parameter Results LOQ Units Method
Allowable
Limits
Prep
Date
Analysis
Date InitContainer ID
Waters Department (Provisional Cert for Nitrate-N)
EBH06/15/22SM21 4500NO3-Fmg/LTotal Nitrate/Nitrite-N 7.24 0.200 (<10) A
Microbiology Laboratory
M.A06/09/22SM21 9223B100mLE. Coli Negative 1 B
M.A06/09/22SM21 9223B100mLTotal Coliform Negative 1 B
2 of 5
Certificate of On -Site Systems Approval
Parcel I.D. 020-413-37 Expiration Date: �T--�
1. GENERAL INFORMATION
Complete legal description PARADISE VALLEY BLOCK 8, LOT 17
Location (site address) 5931 ROMANIA DRIVE, ANCHORAGE, AK 99516
Current property owner(s) GALE D. KNEPPER & DONALD B. CASSAS Day phone
Mailing address
Re�a estate agent
5931 ROMANIA DRIVE, ANCHORAGE AK 99516
fray phone
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
®
Private Septic
❑
Water Storage
❑
Holding Tank
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 5 5 D
Date of Payment 19 8 old
Receipt Number 1�00 33
COSA # O S C ).117 01
Date:
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE AK 99516
Engineer's Printed Name CURTIS HUFFMAN PE Date 12/6/2021
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any estimate of how long function
®' •,
Aw��': • -
a system will satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting & NES .
e *. T1•I '.
6.
�� • • •
DSD/ SIGNATURE
' Curtis Huffman
�$��`��s
'✓ System #1 Approved for 3 bedrooms
•- CE 128991 •.c��d
� eF ' • .12/6/21 ''tib
System #2 Approved for bedrooms
���F�'°ROFESSOW
Disapproved
_ Conditional approval for bedrooms, with the following stipulations:
WATER AND
BY Original Certificate Date: 3 as n o
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory cX Other
COSA Checklist
Legal Description: PARADISE VALLEY BLOCK 8, LO 17 Parcel ID: 020-413-37
If more than 1 septic system on lot: COSA Checklist #
of
Structure served by this system
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 11/8/1984
Total depth 328 ft
Cased to 21 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 8/9/2021
Static water level at beginning of test 41 ft.
Well production at time of test 0.67 gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 4.43 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date of Sample 8/3021
Comments
B. TANK DATA
Age of tank(s) NEW years
Tank type/material HOLDING TANKS / STEEL
Measured operating fluid level in septic tank
Standpipes/foundation cleanout per record drawing
Date of pumping
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field
Monitor tubes go to bottom of effective. If not, state
depth into effective
Code-required soil cover over field
System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Adequacy test date
Results Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
Comments/Deficiencies:.
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100’
Yes if No
ft
Neighboring Tank > 100’ Yes if No *75+ ft
Absorption Field on Lot > 100’ Yes if No NA ft
Neighboring Absorption Fields > 100’
Yes if No
ft
Community Sewer Main > 75’ Yes if No
ft
Community Sewer Manhole/Cleanout > 100’
Yes if No
ft
Private Sewer/Septic Line > 25’ Yes if No
ft
Holding Tank > 100’ Yes if No
ft
Animal Containment > 50’ Yes if No
ft
Manure/Animal Excreta Storage > 100’
Yes if No
ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Property Line > 5’ Yes if No
ft
Absorption Field > 5’ Yes if No NA ft
Water Main > 10’ Yes if No
ft
Water Service Line > 10’ Yes if No
ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No
ft
Community Wells > 200’ Yes if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10’ Yes if No
ft
Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No
ft
Water Service Line > 10’ Yes if No
ft
Surface Water > 100’ Yes if No
ft
If absorption field is under driveway comment below
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No
F. ENGINEER’S COMMENTS
*SURVEYOR MEASURED 107’ TO CLOSEST VISIBLE LOT 18 STANDPIPE TO LOT 17 WELL. WELL IS 75-100’+
TO HOLDING TANKS ON LOT 18 & MET CODE AT TIME OF INSTALLATION.
G. ENGINEER’S CERTIFICATION
I certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
12/30/2021
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT 907‐343‐7904
On‐Site Water and Wastewater Section Fax: 343‐7997
www.muni.org/onsite
Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org
Well Water Advisory
Certificate of On‐Site Systems Approval # OSC211701
Subdivision: Paradise Valley, Block: 8, Lot: 17
This well’s productivity was determined to be 0.67 gallons per minute. The
minimum well productivity required under (AMC 15.55) for a 3‐bedroom residence
is 0.31 gallons per minute or 150 gallons per day per bedroom. Although the
subject well currently exceeds this minimum requirement, the production capacity
can fluctuate and may be insufficient to meet your needs.
This advisory must be attached to all copies of the subject Certificate of On‐Site
Systems Approval.
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL ~ALTH
DEPARTMENT OF h~ALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR ~ALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information
Application Date
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Applicants Name ~oh ~,~ Telephone - Home Business
Applicants Address ~F31 ~e$~e~ /~r.J~o,-,~j~ Zq~'A~ ff~-O ~-
(C) Applicant is (check one) Lending Institution ~--~ ; Owner/buildgr ~
Buyer ~; Other ~ (explain); '
(d) Lending Institution Telephone
Address
(e) Real Estate Coo & Agent
Address
Telephone
(f) Mail the HAA to the .following address:
2. T~pe of Residence
. Single-Family~ Multi-Family~
· Number of Bedrooms ~
Other (describe)
3. Water Supply-
Individual Well ~ Community ~ Public
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
Sewage Disposal
Onsite .~ Public ~ Community ~-~ Holding Tank ~
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 2]
5. Engineering Firm Providing Inspections, Tests~ File Search~ Data and Information
e
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adeqnate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection°
Name of Firm
Address
Telephone
Date
(ENGINEER SEAL)
· Approved for~'.~ bedrooms By
: Disapproved
Approved ' ~/~'~
Terms of C0~ditional Approval
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY AiPPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN ~ PROFESSIONAL ENGINEER'S WORK.
RR4/ej/D18
[Page 2 of 2]
(DHEP SEAL)
7'19-84
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
~neral Information Application Date
/ /
(a) Legal Description (include lot, block, subdivision, section, township, range)
!
Location (address or directions)
(b) Applicants Name ~c,~ ~c~ ~.~ Telephone - Home Business
(c) Applicant.is (check one) Lending Institution ~ ; Owner/builder~
uyer[ ; Other[222(e×plain);
(d) Lending Institution Telephone
Address
(e) Real Estate Co. & Agent
Address
(f)
Telephone
Mail the HAA to the following addreSs:
1~:~'.. z~:~ ~ .... :5~ ~:.--~:-'-->'"~'
2. ~ype of Residence
Single-Family~
Number of Bedrooms
3o Water Supply
Individual Well~"~
Multi-Family~
Other (describe)
Community~--~ Public~
Note: If community well system, must have written confirmation from the State
Departmen~ of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal
Onsite ~ Public ~-~ Community ~ Holding Tank ~
Note: If community well system, must have written confirmation from the State
~__ Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 2]
5. Engineering Firm Providing Inspections, Tests~ File Search, Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
Telephone ,)"-z~l J-o ¥ o
e
Date ~ 5- /f-'~" ,',~ OF ;~,
(ENGI~ER S~)
DHEP Approval -
Approved for /1I~ bedrooms By
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR A~ALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
RR4/~j/D18
[Page 2 of 2]
(DHEP' SEAL )
,,.; \t i
7-19-84
ae
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
Legal Description:
Well Classification
Well Log P~esent (Y/N)
Total Depth 3 2 %~ ~- Cased
Static Water Level ~ /
Casing Height Above Ground
Electrical Wiring in Conduit (Y/~
Separation Distances from Well:
To Septic/Holding Tank on Lot
If A, B, c~ C, D,E.C. Approved(Y/N)
Date C~,pleted {Vov ~ /~yw Yield
~pth of ~outing
Sanit~ ~al on Casing
~ession ~ound ~l~ead (Y~
; On Adjoining Lots
' fu
TO Nearest Edge of Absorption Field on Lot /~f?.)~; On Adjoining Lots
To Nearest Public Sewer Line tV/~ To Nearest Public Sewer
Cleanout/Manhole 1%/~ To Nearest Sewer Service Line on Lot
water Sample Collected By ~ ; Date .~/{/ ~ ~/~
Water S~e Tesf'hResults
lDO +,
f~0 +
B o SEPTIC/HOLDING TA~K [i~TA
Date Instal~e~:d~t.~ / ~l/g~ Size / O O_ 0 L NO. of Ccmpartments
Standpipes ((Y~) ~ ~ Ai=-tight Caps (Y/~ Foun~tion Cleanout
~ession ~~ (Yd~ ~ ~te ~st P~d
P~ing~intenan~ ~n~a~ ~ File (Y~) ~" ; for
Holding Ta~ High-Water ~a~ (Y~) ~% ~r~ Holdi~ Ta~ ~r~t (Y~
~p~ation Distan~s ~ ~ptic~lding Ta~: '~'~
TO ~te~-Supply ~11 /0 ~'/ To ~ilding F~ndation
To ~o~rty Li~ ~ ~ I ~,/~ TO Dis~sal Field
To ~ter ~i~rvi~ Lir~ /O~c" To S~e~, Pond, ~e, ~ ~jor ~aina~
~ ~~ / Receipt ~
2-15-84
C. ABSORPTION FIELD DATA
Soils Ratin~ in Absorption Strata
Date .Installed /l.
Width of Field 30
Square Feet of Absorption A~ea
Depression over Field (Y~
Results of Last Adequacy Test
/5 %3 / ~'~ype of System Design
Length of Field ~ ~ ~'
Depth of Field /' ~ ~
Gravel Bed Thickness D%~/~/~/~.~3~
~ StandpiDes P~esent d~N!z
Date of Last Adequacy Test
Separation Distano~ f~om Absc~ptio.q _F, ie%~
To Water-Supply Well
To Building Foundation
Lot A
To Water Main/Service Line
To Stream/Pond/Lake/c~ Majo~ D~ainage CoL~se /00
To D~iveway, Parkin~ A~ea, c~ Vehicle Stc~age A~ea
To P~operty Line t Y ~
TO Existing or' Abandoned System cn
; On Adjoining Lots / ~7 ' ~)f'f~cA_,,~ -~'/..~ ~.%..~/t3~.~..~t -
/O '-~ '~: TO ~t~(if pre~nt) ~
Comments
Do LIFT STATION
Date Installed /~.~
Size in Gallons ,/~
"PLaiD On" Level at ///%
High Water Alarm Level at
Tested for
Electrical Codes(Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
~ing Cycles ~ing Adequa~ ~st.
Meets MOA
** Check Permitted Bedroc~ Rating Against HAA Request
I ~rtify that I have checked, verified, c~ confom~ed to all MOA HAA Guidelines in effect
on the date of this inspection.
Signed
Company .
KB1/d5/s ~__
[Page 2 of 2]