Loading...
HomeMy WebLinkAboutPARK HILLS #1 BLK 2 LT 6parK fills S/a Municipality of Anchorage Page 1 of 3 Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 13WO50169 PID Number: 017-142-23 Name: Wastewater System: Upgrade Marc and Cathy Bond Address: 14720 Park Hills Circle Anchors e, AK 99516 ABSORPTION FIELD Phone: Number of Bedrooms: §r Wide Trench 345-6075 Four 4 Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION 8 GPD/Ft' 6.5 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 2 6 Park Hills No. 1 2.5 Ft. 4 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: - Fl. 90 Ft. Gravel width: Number of lines: Distance between lines: Well: Existing 5 Ft. 1 Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Ft. Ft. 900 Ft2 ASTM P5054 FVC Driller: Date Drilled. Static Water Level: Installer: Date Installed: Ft. Acres e S otemo 7/2-7/2003 Yield: Pump Set at: Casing Height Above Ground: TANK GPM Ft. Fl. SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ublic/Private Manufacturer. Capacity in Gallons: From Tank Field Station Tank Sewer Line Anchorage Tank 1,250 Material: Number of Compartments: Well >100' >100' N/A N/A >25' 5teel Two 2 Surface Water >100' >100' N/A N/A LIFT STATION — NONE ON LOT Size: Manufacturer: Lot Line >5' >10' N/A N/A Gal. >5' >10' N/A N/A "Pump on" level at: "Pump off' level at: High water alarm at: Foundation in. in. in. None Noted Pump Make & Model Electrical Inspections performed by: Curtain Drain Remarks' BENCH MARK Diverter Valve Flaced and Existing Absorption Trench Tied in Location and Description: for Fossible Service in the Future. 2" of Insulation Over Both Bottom Floor Door Jamb Front Yard. Septic Tank and New Trench. Existing Septic Tank Fumped Assumed Elevation: 100.0 Ft. Crushed and Buried On Site. Engineer's Stamp OF 49th Inspections performed by: MEA Dates: list 7/2/2003 i •'•�'� .Lud -i ''MICHAEL E. ANDERSON •�♦ i•% Department of Hea t and Human Services approval NO. CE-4381 ••••��/ O�TF '��`4r Reviewed and approved by: Date: ��(ReV. 10/99) ♦� ,�NiIKILIX •�••••. v r0,y s�ase"'e°t�� 63 Sri 22'F yv, V C J~ PLAN AS -BUILT Q� SCALE 1" = 40' LOT 6, BLOCK 2, PARK HILLS NO. 1 Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030169 PID No. 017-142-23 Setb acK A B Creek 100' S1 30.0 20.8 o i� s S2 38.0 28.5 0� M1 61.8 54.4 C4 54.5 55.3 y~ q� C5 85.2 75.6 w ,89 DV 42.3 32.9 C5 ov S2 � 3 E y ° Four Bedroom CU LU m ""' ® Home w TH o°pper bk •, Columns r C4 •:.•' ' •. t Existing Well r0,y s�ase"'e°t�� 63 Sri 22'F yv, V C J~ PLAN AS -BUILT Q� SCALE 1" = 40' LOT 6, BLOCK 2, PARK HILLS NO. 1 Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030169 PID No. 017-142-23 L N 41 N 96.5 L > N (U(7 > 6 (4 N UU L7 > IU To Existing Septic Tnnk 1,250 Gallon Absorption Trench LD i c U r f U PROFILE AS -BUILT Scale: 1"= 10' r MUNICIPALITY OF ANCHORAGE 1 I L 3 Cj Development Services Department l On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW030169 Legal Description: PARK HILLS #1 BLK 2 LT 6 Date Issued: Jun 04, 2003 Expiration Date: Jun 03, 2004 Parcel ID: 017-142-23 Design Engineer: 0014 Anderson Engineering Site Address: 014720 PARK HILLS CIR Owner Name: MARC AND CATHY BOND Lot Size: 50571 SQ. FT. Owner Address: 14720 PARK HILLS CIRCLE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE, AK 99516 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. ONLY, POSED ABSORPTION; FIELD. WHICH THIS PERMIT IS ISSUED TO CONSTRUCT IS APPROVED' AND ADEQUATE FOR FOUR:(4):BEDROOMS Received By: Issued By: 1 Date: U (1 Date: 1 41ky Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-142.23 Permit Number SWO30/69 Property owner(s) Marc and Cathy Bond Day phone 345.6078 Mailing address (1) 14720 Park Hills Circle Anchorage, AK 99516 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 6 Block 2 Park Hills Subdivision No.1 Legal description (Section, Township & Range) Lot Size 5,052/ Acres q.F . THIS APPLICATION IS FOR: Number of Bedrooms Four (4) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. el (Signature of property owner or authorized agent) Permit Fees: Waiver Fees: Date of Payment: JU��� (p �, Date of Payment: Receipt Number: 36C17b Receipt Number: (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522.7773 522-6779 (FAX) May 27, 2003 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 6, Block 2, Park Hills Subdivision No. 1 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing septic system on Lot 6, Block 2, Park Hills Subdivision No. 1 has failed and must be replaced. We are therefore requesting a permit be issued for the construction of a new septic system to serve the four-bedroom home on the lot. The attached Site Plan and backup documentation identify the location of and configuration of the new septic system and the parameters used in the design. Also identified on the plans are the existing septic system, test hole location and the existing well on the lot. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test hole placed near the location of the proposed absorption trench indicated clean sand with some gravel and varying amounts of silt with a percolation rates approximating 5 minutes per inch in the upper 5'. Material below this level became siltier and tighter and the percolation rate dropped to 30 minutes per inch. We are therefore proposing a blended application rate of .8 gallons per day per square foot for the design of the new absorption trench. Ground water was found at 12' during placement of the test hole and did not vary from that level during the monitoring period. We are therefore proposing to replace the existing septic tank with a new 1,250 -gallon septic tank and a 75' long x 5' wide x 4' effective depth absorption trench. The distribution pipe will be placed 2' below the existing surface and the total depth will be 6'. Sufficient fill will be placed over the septic tank and 2" of insulation will be placed atop the absorption trench to prevent freezing. A flow diverter valve will be installed to tie in the existing absorption trench for possible future use. Lot 6, Block 2, Park Hills No. 1 May 27, 2003 Page Two The ground surface on the lot slopes as shown on the site plan from north to south at varying slopes. The absorption trench will be constructed at the front of the existing decorative retaining wall on the lot parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from any surface water and 100' from all wells in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, nla-t-1 cato"J� Michael E. Anderson, P.E. Attachments 49th ; 1 MICHAEL E. ANDERSON No. CE -4381 ?ROFESS���i N 3 m N P 1 A N V•y = cv h W 5 N tOp,D $elb�kEsm 2 6282 6q 66 2A214 150.02 C: 1,52m1&0ma Esml 0 gE1ec gsmt e\ t2?l _ r> N 2p X30.33 280.3 W Sl 110626 Sl 11283 to � A ° setback Esml N J m N A t0plCt a i Replace Sx.titj Tank W itF Naw 11`.AGallen Sepllc Tack pi, 5P N S.Pfil o 'L .9 IVWk. e C.MF pu n T. h 6 � 0 O �m F eHeBia.m qz �Y � • a.' •i °� o � a. ho Elathl0 aN t:.:Y A. S 6� P A-- .1 �4S V `°° ,bro r� J O 16 h 17 M ° e°Fs 24jZ7 4 nl .•JOE ......♦'+♦i MF 49t♦♦� %.....3 ................... i�^, ,1► m MICHAEL E. ANDERSON .....................................MAEL� AREA MAP ♦C� '• NO. CE-4381 _� ♦s ♦♦�••• )Ns . • SCALE 1" 'NOFESSICN = 100' �,- 100' Place Diverter Valve Ar'' Tie In Existing Trench `��� t° �ti Replace Existing Tank �J With New 1,250 Gallon `��,, Septic Tank (99 75' L ng x 5' Wide x 4' E ffec tive Depth Absorption Trench - 3% 3 N w V `_01. TH 3016 4 MICHAEL E. ANDERSON NO. CE -4381 peft- ESS\OPi 6 3d F ur Bedroom Home Existing Well SITE PLAN SCALE 1" = 40' t LOT 6, BLOCK 2, PARK HILLS SUBDIVISION NO. 1 DESIGN FACTORS: Four Bedroom House Perc. Rate: 5 Min./Inch Application Rate: .8 GPD/SF (Average) SYSTEM REQUIREMENTS: 5' Wide Trench System 1,250 Gallon Septic Tank 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Appplication Rate) = 750 SF Absorption Area 750 SF/5 LF (Width)* .5 (Red. Factor) = 75 LF Trench Length THEREFORE: Construct a 75' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Maintain 100' Separation From Well on Lot. Place 2' of Direct Bury Insulation and 2' of Fill Over Absorption Trench or Provide Minimum 3' of Cover to Prevent Freezing. Place 4' of Cover Over Septic Tank. Tie In Existing Absorption Trench With Flow Diverter Valve. Natural Backfill 1'6" Geotextile Fabric 6" 4" Perforated PVC (Holes Down) 4'0" I I / I— Drainfield Rock 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST PROJECT #: PERFORMED FOR: Marc Bond DATE PERFORMED: 5/7/2003 LEGAL DESCRIPTION: Lot 6 Block 2 Park HIRs Subdivision Addn. No. 1 TEST HOLE # 1 SLOPE SITE PLAN OG/Organics I 1 I E 3 4 5 6 7 8 9 14 15 16 17 Silty Sand with Gravel SM Sandy Silt with Gravel ML WAS GROUNDWATER 5% ENCOUNTERED? Yes s N NET DROP L IF YES, WHAT DEPTH? 12 0 1 P DEPTH OF WATER 12' s AFTER MONITORING: 4:41 4�7 ..�_ DATE: 5/25/2003 Q7 ENCOUNTERED? Yes s DEPTH OF WATER NET DROP L IF YES, WHAT DEPTH? 12 0 1 P DEPTH OF WATER 12' 6.5" AFTER MONITORING: 4:41 E ..�_ DATE: 5/25/2003 2 4.° 4 MICHAEL E. ANDERSON No CE -4381 BOHINIb ROFES5I�N�� V. 3%-5 READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 5/7/03 4:10 9.0" 1 4:40 30 2.5" 6.5" Recharge 4:41 9.25" 2 1 5:11 30 2.88" 6.37" Recharge 5:12 9.17" 3 5:42 30 2.75" 6.42" PERC RATE: 5 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 2.5 FT. AND—LS—FT. COMMENTS: Test Hole Presoaked Prior to Test. Material Below 5' Percolates at 30 Min./Inch. Average Applicaton Rate of .8 GPD/SF. TEST PERFORMED BY: MEA I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/26/2003 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 6, BLOCK 2, PARK HILLS SUBDIVISION NO. 1 GENERAL: The scope of this project includes the removal and proper disposal of the existing septic tank and the procurement and placement of a new 1,250 -gallon tank at the location shown on the site plan. Work also includes the construction of a new absorption trench 75' long by 5' wide by 4' effective depth also at the location shown on the Site Plan. The total depth of the trench will be 6' below existing ground and the distribution pipe will be placed at 2' below the surface. All components of the new absorption trench and septic tank must be constructed a minimum of 100' from any surface water or 100' from all wells on the lot and in the area. A flow diverter valve must be installed to tie in the existing absorption trench for possible future use. A minimum of 4' of cover is required over the septic tank and 3' over the absorption trench. In lieu of cover 2" of direct bury insulation and 2' of cover may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from a certified septic tank manufacturer if the existing tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 6, Block 2, Park Hills No. 1 May 27, 2003 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: Lot 6, Block 2, Park Hills No. 1 May 27, 2003 Page 3 of 3 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. M1, MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION II ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ' 1-1 V- Manufacturer 1-55J -' - LJ UPGRADE MAILING ADDRESS = DISTANCE TO: Well a !� r id Foundation Foundation 1 D PERMIT NO. nt No. of lines Length of each line , LEGAL DES.0ION Trench width inches Distance between lines ��- i Top of tile to fini h grade q.z r l ip to Jnlak? Material beneath the q8 inches Rk 14; ILi'T) - Length ', �'� t� �- Depth PERMIT NO. LOCATION %r „„ Crib diameter NO. OF BEDROOMS Total effective absorption area DISTANCE TO: Wall Building foundation Nearest lot line DISTANCE TO: U Y Well /Q-� -L( �q&sorption area r Dwelling Z5 r PERMIT NO. q PERMIT NO. DISTANCE TO: Building foundation J 1- Z Manufacturer Absorption area(s) Material -� No. of compartments W H Liq. capacity in gallons Inside len th IF HOMEMADE: g Width Liquid depth c� I-' DISTANCE TO: Well Dwelling i PERMIT NO. V = Z FQ- Manufacturer Material - Liquid capacity in gallons = DISTANCE TO: Well a !� r id Foundation Foundation 1 Nearest lot line 17 , PERMIT NO. LL z Z w ~ No. of lines Length of each line , Total length of lines Trench width inches Distance between lines ��- F Top of tile to fini h grade q.z r l ip to Jnlak? Material beneath the q8 inches Total effective absorption ar a y SIM A LU C7 Length Width Depth PERMIT NO. i F wa W Type of crib Crib diameter Crib depth. Total effective absorption area DISTANCE TO: Wall Building foundation Nearest lot line J W Class Depth Driller Distance to lot line PERMIT NO. DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER i PIPE MATERIALS SOIL TEST RATIfV i b o INSTALLER PC EX V 4-- -- 12 -4 - REMARKS II fI Ul0.i _' C r , Meir APPROVED DATE LEGAL l 72-013 (Rev .1/7R) L / Block Z V Well .0. Box 10-378 • 10300 Old Seward Highway. f (907) 349-8535 ANCHORAGE, ALASKA 99511 DRILLING LOG Mark Bond Location (address of: Township, Range, Section, if kn Lot 6 Block 2 Park Hills Subdivision ; or distance main Size of casing bit Depth of Hole 161 feet Cased to---161----feet of WellDomestic Static water level 69 ft. lrae"oW (below) land surface. Finish of well (check one) open end ( xxx ) ; Screen ( ); Perforated ( ). Describe screen or perforation None Well pumping test at 15 gallons per (minute) for 1 hours with 100% x3ft'c of drawdown from static level. Date of completion June 27, 1984 WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of mate610lcciv1gnjtrdi Y Doss -Ef Or HET— FILTH gn°A-9c ENVIROi�MENTAL P;Z07F( ile{�_ 0 TO 2 Casing stickup 2 TO 6 6 TO 10 10 TO 13 13 TO 20 20 TO 28 28 TO 57 57 TO 6o 60 TO L52 1� 2 .rte 161 T0- TO- TO- T0- Organics OTOTOTO Organics NOV �/�- I0@4 Silty gravel (wet) _ Hard -pan Silty gravel Sil 1°i ..e cafe Aro, ��f 9tr?ctor 1 —CUSTOMER ^' ^ / MUNICIPALITY OF ANCHORAGE ' ~ ^ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION � 825 L STREET/ ANCHORAGE., AK 9950:1 1 264-4720 0«"—:E3 1~rF= :s F=-wUEF? a PERMIT NO: 840209 DATE ISSUED: 05/07/84 APPLICANT: WINTER MISE INC. ADDRESS: 7400 E. 20TH ANCHORAGE.- HK 99504 CONTACT PHONE: 223-5877 LEGAL DESCR%P LOT SIZE: MAX BEDROOMS SUBDIVISION: PARK HILLS SECTION: 34 TOWNSHIP: 12N 50571 (SQ.FT. OR ACRES) LOT: 6 BLOCK:2 RANGE: 3W LISTED BELOW ARE THE OPTIONS AVAILABLE TO YOU IN DESIGNING YOUR SEPTIC SYSTEM. CHOOSE THE OPTION _-____-~-__--~-___~.-~--..~-~_~.~._~..~---_-~.-~.~__ THAT BEST FITS YOUR SITE. ' -Ir FR FE t-4 f--. E� E: E -s L.A. DEPTH TO PIPE BOTTOM (FT.) 5.0 6.0 5.0 GRAVEL DEPTH (FT.) 4.0 0.5 3.0 TOTAL DEPTH'(FT. ) 9. 0l 6. 5 8.0 13RA9EL WIDTH (FT. ) 2.5 21.0 5�0 GRAVEL LENGTH (FT.) 69.0 40.0 65.0 GRAVEL VOLUME (CU.YDS. ) 28.7 31. 1 42.1 TANK SIZE (GALS) 1-1.-000.0 *# 1/000. 0 000. 0 ** SOIL RATING (SQ. FIT. -�GR) 183 18] 182% ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS ____-~-__~__~____- -__-_~-__~__-_- -__-___ I- CERTIFY THAT: 1. I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE (MOA) AND THE STATE OF ALASKA. 2. I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH ALL MOR CODES AND -REGULATIONS, AND IN COMPLIANCE WITH THE DESIGN CRITERIA OF THIS PERMIT. 3. 1 WILL ADHERE TO ALL MOA AND STATE OF ALASKA REQUIREMENTS FOR THE SET BACK DISTANCES FROM ANY EXISTING WELL/ WASTEWATER DISPOSAL SYSTEM OR PUBLIC SEWERAGE SYSTEM ON THIS OR ANY ADJACENT OR NEARBY LOT. 4. I UNDERSTAND THAT THIS PERMIT IS VALID FOR A MAXIMUM OF 3 BEDROOMS AND ANY ENLARGEMENT WILL REQUIRE AN ADDITIONAL PERMIT. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY II0H BUILDINGCODES, THEN (1> AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED.: (2) AS-BUILT5 WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT/ AND (I) THE ELECTRICAL WORK MUST BE DONE BY 8 LICENSED ELECTRICIAN. APPLICANT: ISSUED 09 DATE-: DATE: t-ISE ���_ L_� --�------------ --- ' 77 �� " • s: MUNICIPALITY OF ANCHORAGE ae µ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST PERFORMED FOR: LEGAL DESCRjI'�PTIONh: J ( c t_r,(J/�p� I" V V .i 2 3 i� n 4- 6 6 6— PJ 9 im 10 11 12 13 14 15 16 17 18 19 20 PERFORMED BY: 72-008 (6/79) DATE PERFORMED: v[� SOILS LOG q4 6 D 6 PERCOLATION TEST b1l 'S in SLOPE SITE PLAN .4L WAS GROUND WATER S ENCOUNTERED? L O P IF YES, AT WHAT E DEPTH? 7t— PERCOLATION RATE �' /I? (minutes/inch) TEST RUN BETWEEN S'51S FT AND �' FT CERTIFIED BY: DATE: I � �' UMME 0,41 PERCOLATION RATE �' /I? (minutes/inch) TEST RUN BETWEEN S'51S FT AND �' FT CERTIFIED BY: DATE: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date —Hat,,( < g GENERAL INFORMATION . (a) Legal Description (include lot, block, subdivision, section, township, range) r �� & V7. '2 a,rc , As S bcl`1vlSion Aad 82 -(32 Location (address or directions) 14i2.0 Wfri iS cwcAvv,�r JL (b) Applicant Name M p✓(C 50na Telephone: Home 45—(.9079 Business 2.7 9 _ 35 S ��t, #W+00 r�y'G� oraq� AK �j`150) Applicant Address t 0 07 �"" ��� �e � ' (c) Applicant is (check one): Lending Institution 13; Owner/builder; Buyer 11 ;Other 11 (explain); (d) Lending Institution /�10.5�to� 1 uci�rlc may -_ Telephone 5 0219 AIL �`�` 10 �A�}v,: Lawrie 1-i�i e Address 60A 100420 1,c� �+" Up orp.a. W e b6 1 (e) Real Estate Company and Agent A Address Telephone (f) Mail the HAA to the following address: l70 AhcYlorc� z R q5o� A h 2. TYPE OF RESIDENCE Single -Family Multi -Family ❑ Other Number of Bedrooms 3. WATER SUPPLY Individual WelI K Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (11/84) Page 1 of 2 5 ENGINEERING FIRM PROVIDIN'G.SPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the va ation wastewaterhownelow,dispoI v rifythterra s safe, fun my investti do of thisand Health Authority Approval shows that the on-site water supply for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Cb�ify„a,ti. E tnttr5 'fin e e Telephone Name of Firm sn t AyC, , X1956 } Address Date 6. DHEP APPROVAL . Approved for bedrooms by Approved - t Terms of Conditional Approval y/o•oeo ee eeoo. �'E 4 r6 ST WUpham, EE���'��" - 5829 ; •.,`'p.'y dhep CAUTION Date Engineer's Seal The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) MUNICIPALITY OF ANCHORAGE (MO'AT' HEALTH AUTHORITY APPROVAL (HAA) MUNICIPALITY OF ANCHORAGE CHECKLIST - FEBRUARY 1984 r DEPT. OF HEALTH & 264-4720 QQ ENVIRONMENTAL PROTECTION Legal D scription: L, v 2 P0'A-' NI els N'lAY 16 06 A. WELL DATA REC�1 V`EQ Well Classification ld4" � If A, B, C, D.E.C. Approved (Y/N) Well Log Present (Y/N) — Date Completed ('— 2--7"q4 Yield IS G CM Total Depth 1 (01 Cased to �' Depth of Grouting &" <<ri ov'n Static Water Level &.1q Pump Set At t�riknowh Casing Height Above Ground 2' Sanitary Seal on Casing (Y/N) y Electrical Wiring in Conduit (Y/N) z Depression Around Wellhead (Y/N) Separation Distances from Well: ' To Septic/Holding Tank on Lot (1 On Adjoining Lots ? I CSO/ To Nearest Edge of Absorption Field on Lot i On Adjoining Lots i To Nearest Public Sewer Line iJ To Nearest Public Sewer Cleanout/Manhole Ni A To Nearest Sewer Service Line on Lot N Water Sample Collected by G wry ;Date S " 14 =(o Water Sample Test Results > tt Comments J n "Y vr) aA„"^ pa'nc "J�ll pA B. SEPTIC/HOLDING TANK DATA 5-16- 4 1250 z Date Installed Size No. of Compartments Standpipes (Y/N) ) Air -tight Caps (Y/N) y Foundation Cleanout (Y/N) Depression over Tank (Y/N) N Date Last Pumped <t , Pumping/Maintenance Contract on File (Y/N) NA ; for N� Tem orar Holding Tank Permit Y/N N� Holding Tank High -Water Alarm (Y/N) —Temporary 9 ( ) Separation Distances from Septic/Holding Tank: To Water -Supply Well 115, To Building Foundation 31 To Property Line ' S f To Disposal Field 2% 1 To Water Main/Service Line To Stream, Pond, Lake, or Major Drainage Course Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata -15 Date Installed " ZA Width of Field Square Feet of Absorption Area Depression over Field (Y/N) N Results of Last Adequacy Test NA Separation Distance from Absorption Field: To Water -Supply Well 11 3 / 1 To Building Foundation N a Type of System Design Length of Field _ r Depth of Field Gravel Bed Thickness t'2 Standpipes Present(Y/N) Y Date of Last Adequacy Test Rouse WAS hew S Ib��4 1 To Property Line F 7,S To Existing or Abandoned System on I Lot ; On Adjoining Lots ZW To Water Main/Service Line N /-\ To Cutbank (if present) To Stream/Pond/Lake/or Major Drainage Course N P\ To Driveway, Parking Area, or Vehicle Storage Area � 43 / Comments D. LIFT STATION Date Installed N Size in Gallons "Pump On" Level at High Water Alarm Level at . Tested for Electrical Codes (Y/N) Comments Dimensions q1A I\ Manhole/Access (Y/N) "Pump Off" Level at _ Vent(Y/N) Pumping Cycles during Adequacy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that ave the ke e 'fled, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Company CO' Receipt No.� Date of Paymen ` �b 0 ,v",u, a ° A' e ®0� Amount: $ OU'°f` `'o"4�b® Engineer's Seal a ° 000e e000000eo 00 0 000® Ad e000 000 odes ea oeeaeQ Page 2 of 2 V a y G. Upham 7 72-026 (11/84) MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE I. General Information Application Date (a) Legal Description (include lot, block r , subdivision, section, townsh SEG p' range) " � K Locati�o/n address or directions) —41%1/y fHr-K IJP l -,L-5 e,,cC Le: (b) Applicants Name �[%,nfnr /.l nc Telephone fiome33j :i'17Business 333-.SPi77 ApplicantspOdtMit..,a pQ (c) Applies check. EuY Fier o"Od•+I�y ep tya3aut89k4•. (d) Len 'ng Instition a•v96J Addr (e) Real Estat""°Etfe• g'.9 Address Telephone V, Lending Institution explain); =1; Owner/builder � ; . (f) Mail the HAA to the following address: arz s, 2. Type of Residence Single -Family 5EI Multi -Family E�J Other (describe Number of Bedrooms y 3. Water Supply Tel ne Individual wellal Community Public Note: If community well system, Department of Environmental Consmust have written confirmation from the State ervation attesting to the legality and status. 4. Sewage Disposal. Onsite [Ha Public F=j Community 77 Holding Tank Note: If community well system, must have written confirmation from the State / Department of Environmental Conservation attesting to the legality and status. [Page 1 of 23 5. Enineering Firm Providin Inspections Tests File Search, Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I the verifysupply m invesf disposalthisasystemtity isrsafeA functionalpprovalwa-adhat adequatenforte water supply wastewaterof structure indicated herein. I further verify that; the number of bedrooms and typege based on the information obtained from the Municipality Anchora my investigation and inspection, the on-site water Supp y system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Telephone S C'. 'IF Name of Firm Cc. S d' gap I Address i 21,r, L. t. lc.. JCC-= i� �� Date ®ea am see (ENGINEER SEAL) ea jOoeo� o aM C. it.8 " soo 2231.0 a �F 6. DHEP Approval. �p a®.®°Daae® !. OF � Approved for bedrooms Approved Disapproved Conditional Terms of Conditional Approval CAUTION J TAL THE iNNICIPALITY LTOF ANCHORAGE H AUTHORITY APPROVALENT OF CERTIFICATESTBASEDDSOLELY UPONTHEREPRESENT- RED (DHEP) ISSUES HEA ATIONS GIVEN IN PARAGRAPHTAHE DHEP DOESNTHIS EPASDA COURTESY STOOPURCHASERS EOFRHOMESEAND IN THE STATE OF QUIRE - THEIR LENDING INSTITU IONS DIN O ORDER CONDUCTTO ISINSPECT ONS OR ANALYZE DATA AE BEFORE A BEFORE EMPLOYEE CERTIFICATE IS ISS PROFETHEONMUNICIPALITYAL OF ORKCHORAGE IS NOT RESPONSIBLE FOR ERROR OR OMISSIONS IN THE (DHEP SEAL) RR4/ej/D18 7-19-84 (Page 2 of 2] T G ia3 MUNICIPALITY OF ANCHORAGE (MOA)"Y'` HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Legal Description: A. WELL DATA Legal lJ-/ L,L.S Well Classification P/D U/A•t! If A, B. or C. D.E.C. Approved(Y/N) U/� Well Log Present 1/N) Date Conpleted U'/O Yield /6 C -;PAI Total Depth / G / Cased to J 6 / ` Depth of Grouting .art; nNac�N Static Water Level /-> c Pump Set At Casing Height:Above Ground 2.' Sanitary Seal on Casing (Y, ) Electrical Wiring in Conduit Depression Around bbllhead , I r)? Separation Distances from Nbll: To Septic/Holding Tank on Lot 1 13 On Adjoining Lots > /0o To Nearest Edge of Absorption Field on Lot 14-o4 ; On Adjoining Lots >ioc.' To Nearest Public Seder Line To Nearest Public Sewer Cleanout/Manhole/, To Nearest Sewer Service Line on Lot_ Water Sample. "Collected By (,u r- ; Date %// L Water Sample Test Results is sic !-A- Comments;p.kAMfsif �� /n9 . B. SEPTIC/HOLDING TANK DATA Date Installed S 6 4 Size 17,E No. of Compartments Standpipes %4'I) Air -tight Caps ) Foundation Cleanout ( /N) Depression over Tank (Y } Date Last Pumped L -i t IN Pumping/Maintenancee Contract on File (YM) ° '- for L' Holding Tank High -Water Alarm (Y/N) Temporary Holding.Tank Permit (Y/N) rU Separation Distances from Septic/Holding Tank: To Water -Supply Wall cl To Building Foundation To Property Lire S / To Disposal Field 2 To -Water Main/Service Lire t1 / To Stream, Pond, Lake, or Major Drainage Course v 3 Conirents60VIAW rA (Page 1 of 21 (O/�c�'�� 2-15-84 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 8_s ' Type of System Design Date Installed 5�/Gr/"'U Length of Field 7/ Width of Field 3�" Depth of Field Gravel Bed Thickness Li Square Feet of Absorption Area S fi'"' ! Standpipes Present 0/N) Depression over Field (YA Date of Last Adequacy Test 4)In Results of Last Adequacy Test ti �lq Separation Distance from Absorption Field: To Water -Supply Well O To Property Line To Building Foundation Z� To Existing or Abandoned System cn Lot , ; On Adjoining Lots 3c) _ To -Water Main/Service Line A�% _ To Cutbank(if present) 6,(4 To Stream/Pond/Lake/or Major Drainage Course- To Driveway, Parking Area, or Vehicle Storage Comments I/V l4 Llj &-W%~ 41.4e D. LIFT STATION \ Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Code Comments Dimensions �ccess (YM) Off" Level at y�Vent (YM)Pumping cies during Adequacy Test. Meets MCA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA HAA Guidelines in effect on the date of this inspection. Signed Date -n Company (� `�. (,v _ MOA No. S r8(t- -C) -z sc KBl/d5/s (Page 2 of 21 2-15-84