HomeMy WebLinkAboutROLLING HILLS ESTATES BLK D LT 5I ol I lng Hill lock b Lot ! 1-072 -29 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME~ LEGAL DESCRIPTION , ~ ' LOCATION ~ 0 ~ 'DISTA'CE TO: ~ ~ ~8nufoctureF ~ -- ~ D STANCE TO' Well ~ Manufacturer ' I Q m IWe)l ~z I DISTANCE TO: I / ~ N Top of tile to finish grade ~ Material beneath tile ~ ~ ~ngth Wid~ Depth ~ ~ ~ Crib diamete~ Crib depth ~ Well ' Building foundation ICI~s Depth Driller ~ [ ~ Budding foundatlo~ Sewer line Materi~--~_.~ ~.~.~ Width Material Nearest lot line Distance to lot line Septic tank Nearest lot iTC., / ¢. Trer~th inches (~¢~ inches q~ ~'¢~:~ I E~UPGRADE I NO. OF BEDROO~ No. of ~_.~artments Liquid depth PERMIT NO. Liquid capacity in gallons D istanc Total e,~¢~ion area PERMITCNO'. Total effective absorption area PERMIT NO. Absorption area(s) OTHER PIPE MATERIALS~ . f2 · scm, ST AT, G INSTALLER REMARKS ~-,,1o ,- too', DATE LEGAL •i;ox 13000 $TAR Rotrzm A', A-NC$ORAGVq ALAIRKA 0050:2 SIX INCH WATER WELL DRILLED, AND CASiZD OUT TO THE DEPTH OF 12$ 3^ DRILLED AT THE RATE OF - 119400 PER FOOT. PROPERTY OWNER 1 �AAIF.t ui'ifR 2777-6236 LOCATION OF WELL SITE'•- fit.'' ; ,,,,�F : D 5" a 1 -& � DRILLER &Ail a _rJMLA dZ „A=pawt f1rt) ll4a lk,&LA r WELL LOG: : r" w t, i 0----33 Cow -we 4wra-� 2N fir'yA 'get - 95X 124 get 9 X124R if" -d" sand 0 -M -A 301 ktiy. 'Sl �t*�����n tom_• '-�1� __.__ 124-1 Good Good mean t baa.Lat vtth a nrtoducftan o�Of rsi.th a 45 .Loot 4tand'ot, . nwsrng. 1/2 moua Sub_A=A ehogU &e 4jfataU4d 10_ t*k OU 1 o01L' .oM. coat 119x00 X 125 12375oOO Coat 0.4 kleu Seat: 121.00 COST INCLUDES ALL LABOR AND MATERIAL 1 Est COMPLETION OF SAID DRILLING:. WRITE CHECK PAYABLE TO OAMPART DRILLING WORKS FOR THE SUM OF THANK YOU VERY MUCH. BEEWPI CLAUS OF RAMPART DRILLING WORKS DATE__ lim 2nd_ 1070 BEftVftL� CHARGE b F 1i/.4 PtV6 WILP L AON AST DUE ACCOUNTS.__+ PERMIT NO. FIPPLICFINT JBMES R. LITTER i844 E. LOC~TION W. ~RD 8VE LEGFIL L5 BLK D ROLL. lNG HILLS EST TYPE OF SOIL FIBSORBTION SYSTEM IS: TRENCH MR~IMUM NUMBER OF BEDROOMS = ~ DEPRRTMENT OF' HEFtLTH FINE:, EN',,,'IRONMENTFIL PROTECTION 825 '" L '" STREET., FINCHORRGE, RK. 995Et:'L 264'-472E~ ) ,.._.1-.: 1 I"1 R',,,'E:: L.O'T' SIZE 53:~."_1¢} SL.':!LIFIRE FEET SOIL F..HT I N ..~ 'T'HE REQUIRED :SIZE ElF' THE SOIL RBSORPTION :_.,-r.:,TEfl IS: THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIEL.[:'. THE DEPTN OP' FI TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFFICE OF THE GR. OUND FIN[:.', THE BOTTOM OF THE E).,',CRVRTION (IN FEET). TFIERE IS NO SE'r WIDTH FOR TRENCHES. THE GRR',/EL DEPTH IS THE MINIMIJM DEPTH OF GRFIVEL. BETWEEN THE OUTFFILi.. PIPE RND THE BOTTOM OF THE EXCRVFITION (IN FEET). PERMIT FIF'PLIC:FtNT HH=, THE F,E.=,Ft.N.:,IE, ILI"fT TEl INFORM THIS [.,EFHF, FfIENF DLIRING ]'FIE fHI :, F F.' _ F EF, t ~ RN[:, ]'HE: it'.tSTRLLRTION INSF'ECTIONS OF RN'¢ WELLS RDJRCENT TO ' o NUMBER OF RESIDENCES THRT THE WELL [,JILL ..... EK,E. . -'-" . ~'~{ ~ '. E. F' E' ~':,:" ! I ]: IF':: FZ ]'"'i...tC~ ,:' .=-.. ':, ."f I'.,.~SF"E..:C:"]F Z C~I"-41.":_; -- ~" - E:FICI-:::FIL.,LING OF F:INY .:'r_,TEM WITHOUT FINRL IN.=,FEC'TI.N RND FtF'PRO',,,'FIL B'T' THIS [:'EPFIRTMENT W ILL BE SUBJECT ]'O PRE'SE 7 L ]"I ON. MINIMUM DISTFINCE BETWEEN FI WELL. RND FINY ON-SITE SEWRGE DISPOSRL.. S"r'STEM IS :I. EIE~ FEET FOR R PRIVRTE WELL.; OR tSEl TO 2EsZI FEIET FROM R PUBL. IC 14ELL DEPENDING UPON ]'PIE TYPE OF PUBL. IC WELL. P.IELL LOGS RRE REQUIRED RND MUST BE RETURNED TO THE DEPRRTMENT WITHIN 2:[,,"'-'~ DRYS OF THE [,JELL. COMPL. ETION. OTPER REI;!UIREMENTS MA~' FIPPLY. SPECIFICFITIONS RND CONSTRUCTION DIRGRRMS RRE BVFtILRBLE TO iNSURE PROPER INSTFILLR'f'tON. I CERTIFY THRT :t..: I FtM FFIMILII=IR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS FIS SE'T' FORTH B"r' THE MUNICIPRLITY OF ~NCHORFdGE. 2: I WILL INSTRLL THE S'¢STEM IN RCCORDRNC:E WITH THE CODES. ]:: I UNDERSTRND THRT THE ON-SITE SEWER S'T'STEM f"IRY REQUIRE ENLFIRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE [dORE THRN :~ BE[:,ROOMS. RPF'LICFINT ..lEgalES R. IJTTER 4040"B" STREET ANCHORAGE, ALASKA 99503 ~. John Bagoy c/o Karl Bachner 1135 W. 8th Avenue (907) 278-1551 July 5, 1971 W.0. #A1849l Dorothy Barrett ~; THE BACHNE~,. Commercia~JPi~L Anchorage, AK Subject: 99501 Home: (907) Z72-lg42 ?~}~"~ r~ esiden tial daska, 9950~ . Offide: '(~7) ~4-159 Subsurface Investigation, BlockS' Rolling Hills Estates Lc'~' / Dear b~. Bagoy: At the request of Mr. Karl Bachner, we have conducted the. subject exploration- The scope of the investigation includes test holes and percolation tests on lots 4, 5, 6, 7, 8 and 15, 16, 17, Block D, Rolling Hills Estates. Included wi~h this transmittal a~e: ' ': .... %" Vicinity Map Test Hole Location Sketch Test Hole Logs Summary of Percolation Test Results Standard Explanatory Info,nation Figure 1 Figure 2 Table A' Table B Sheets 1-3 Exoloration was conducted on June 22, .1978. A Nodwell mounted Mobile Drill.B-50 rig was used~ The drilling equip- ment is owned and operated by Denali Driling, Inc. Test holes were located in the field and logged by Mr. Joe Williams, staff technician with Alaska Testlab. ~s samples were recovered from the auger flights, they were sealed in plastic bags for protection of the sample and maintainance of their natural moiture content. In the laboratory, the samples were visually classified and'the moisture content and dry strength of each sample was deter-' ]nined. When drilling was Completed, a 3/4" slotted PVC pipe was inserted int~ each ]tole to aid in determining 'the free water level. For the percolation test the hole was filled with water and left overnight to saturate. On returning the next day, the hole was refilled with water and the drop in the water level carefully monitored over the next 60 minutes or longer if necessary in order for the rate to stabilize. .We understand this procedure is preferred by the Municipality of Anchorage, Department of Public Health and Environmental Protection to evaluate the site for proposed on-site sewage . i~ Mr. Karl Bachner ~uly 5, 1978 Page ~ Table B is a summary of the results of trea~J~ent systems. the above tests. No free water was observed in any of the test holes. It should be noted, however, that %he free water level may fluctuate seasonally or with precipitation- We trust the above meets your present needs. If you have any questions or if we may be of further service, please do no% hesitate to contact us. Very truly yours, ALASKA TESTLAB R. Mark Hansen 'RMH:rb Enclosures APPROVED. - ~ ~ ~elvin R. Nichols, P.E. Laboratory Manager pep~h ~ From To 0.0' - 2.0, 2.0' - 5.0' 5.0'.- 16.0, Bottom of Test Hole: Frost Line: Free Water Level: Table A WO #18498 Logged By: J- WilJ Date: 6-22-78 __Soil D~scri~tion Brown ~ea~tt, (Pt}. " '-'----- F-2/F-3 Brown Silty Sand (SM) with trace gravel. ~ .... F-2/F-3 Brown ~ Sand 16.0' - None Observed -Sample Depth 1 2 5.0' 10.0' 3 15.0' M% Type of Dry ~ S~a~pl~e Strength Unified 18.4 --~ 18.2 G N SM G L-N SM 12.4 G N SM Remarks: 1. Type of Sample, G=Grab, SP = Standard Penetration, U = Undisturbed. Dry Strength, N=None, L=Low, M=Medium, H=Hiq'h. Grou~ r ~ . ezers to similar mater/a], this Study only. General Information, see Sheet 1. Frost and Textural Classification, see Sheet 2 Unified Classification~ see Sheet 3. ' TABLE B 4 5 6 7 15 !6 17 Minimum Observed Percolation Rate, Minutes/inch 6.7 3.7 10.0 6.7 6.7 5.7 10.0 Required Absorption Area, ~quare feet/bedroom 140 165 - 140 140 130 165 8.0 150 so'Becausells. sometlmesOf, the. silty tend ~tonatUrecloc°f the site soils and since silty .... . wi~h use, we recommend a more ~nse~va~f%espite of the design aboveVa[ii~eratings.°~ 165 square feet/bedroom be ~ed Municipality of Anchora§e Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 wv~v.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS FOR A APPROVAL SINGLE'S'FAMILY DWELLING Parcel I.D. 01107229 1. GENERAL INFORMATION Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address ROLLING HILLS BLOCK D, LOT 5 5232 WEST 75RD AVENUE JIM U'FFER 5252 WEST 75RD AVENUE ,ANCHORAGE~ AK 99502 Day phone *ANCHORAGE~ AK 99502 Day phone 245-7816 Day phone Unless ,¢~t~erwise requested, COSA will be held by DSD for pickup. · ..,~ ~:-~::~ ~..,~. ?., ;, ~ ~.!!,~ U.~..~. 2. NUMBER OF BEDROOMS: 3 TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: · Individual~:Well · Individual On-site [] Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System [] Public Sewer · The MuniCipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wasteWater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems ApprOval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, f verify that my investigation, based on procedures outlined in the Certificate of Qn-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the" on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGEi AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone 557-6179 Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not previde any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of th(s report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE Approved for 3 Disapproved. Conditional approval for __ bedrooms. bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Maintenance Agreements Supplemental Engineer's Report' Other Original Certificate Date: (Rev. 11/05) Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: ROLLING HILLS BLOCK D, LOT 5 Parcel ID: 01107229 WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 6/2/1979 Sanitary seal (Y/N) YES Total depth 125 ft. Cased to 125 ft. Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) YES YES 12+ in. FROM WELL LOG AT INSPECTION Date of test 6/2/1979 8/4/2010 Static water level 80 ft. 76 Well production 20 g.p.m. 9 g.p.m. C= WATER SAMPLE RESULTS: Coliform O colonies/100 mi. Arsenic~', '~ug./L. SEPTIC/HOLDING TANK DATA Tank Type/Material Tank size . gal. 'Foundation cleanout (Y/N) Date of pumping ABSORPTIO~ FIELD DATA Date installed Length Total depth Date of adequacy test Nitrate .~L_[~ mg./L. Date of sample: 8/4/2010 Other bacteria (~ colonies/100 mi. Collected by: GE(;; Ltd. ] PUBLIC SEWER] Date installed Number of Compartments Cleanouts (Y/N) ~ Depression over tank (Y/N} High water ala~~. Pumper Soil rating (g.p.d./ft2or ft~em type Width /~ft. Gravel below pipe ft. .ft. Eft. abs ft Momtonng tube - ---,.,.'~ Results (Pass/Fail) Depression over field For__ bedrooms b Fluid depth in efore test in. Water added gal. New depth Elapsed T?~_ min. Final fluid depth in. Absorption rate >= ~juvenafion treatment (past' 12 mo.) (Y/N & type) If yes, give date in. g.p.d. D. LIFT STATION Date installed "Pump on" level at Size in gallons Manhole/Access ~ J in. "Pump off" leveLa~L~ High water alarm level at in. ~ ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot N/A Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas Meets alarm & circuit requirements? On adjacent lots 100'+ N/A On adjacent lots 100'+ 75'+ Public sewer manhole/cleanout 100'+ 25'+ Holding tank N/A 50'+ Manu~re/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: I PUBLIC SEWER Building foundation Property line Absorption field Water main . Water service line. Surface water ~ Wells on adjacent lots ~ SEPARATION DISTANCE FROM ABSORPT~T TO: Property line. M ~~undation. Water main. Water service line ~ Surface water C~i~~ Driveway, parking/vehicle storage Wells on adjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date ~ [ ,-I / / 0 COSA Fee $ "'/'~ Date of Payment Receipt Number, (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number SGS ReL# 1103859001 Client Name Garness Engineering Group, Ltd Printed Date/Time 08/12/2010 8:10 Project Name/# Roiling Hills Est BD,L5 Collected Date/Time 08/04/2010 12:40 Client Sample ID Rolling Hills Est BD,L5 Received Date/Time 08/04/2010 13:00 Matrix Drinking Water Technical Director Stephen C. Ede Sample Remarks: 4500NO3 - Total Nitrate/Nitrite - MS did not meet QC criteria, biased low. Refer to the LCS for accuracy. Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic 5.37 5.00 ug/L EP200.8 C (<I0) 08/10/10 08/11/10 NRB Waters Department TotalNitrate/Nitrite-N ND 0.100 mg/L SM20 4500NO3-F B (<10) 08/04/10 AYC Microbiology Laboratory E. Coli Negative I 100mL SM20 9223B A 08/04/I0 DLC Total Coliform Negative I 100mL SM20 9223B A 08/04/10 DLC DATE SCHEDULED / / TIME SUBDIVISION ROLLING HILLS ESTATES INSPECTOR BLK/LT/TRACT BLK D LT 5 INDICATE NORTH SIZE MAIN: ,/'..~ ' CONNECT LOCATION: COMMENTS INSPECTED BY: /~ '.5- ';..,.:...~.,__ IDATE: IAT PROP. LINE: DATE SCHEDULED 12/31t2009 TIME 12:00 am SUBDIVISION ROLLING HILLS ESTATES INSPECTOR ~"'..~¢~L.~"~,~ '~. ~~ ..... BLOC~LOT/TRACT BLKD/LTS/ 6Z \, i3'b" tl SIZE MAIN: TYPE MAIN: IDEPTH AT MAIN: AT PROP. LINE: CONNECT LOCATION: / / I °% \ \. t I j / / ? ~ / ? J / / \ \ // ? 1990_ --- 825 L Street - Anchorage, Alaska 99501 "- AUG 2,  ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720R E C E 1 V E REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES ~)IRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days fo~ processing. 1. PROPE~ OWNER PHONE da'me~ ~ ~,~¢~ I~-~/~ PROPERTY RESIDENT (If different from above) PHONE 2. BUYER PHONE MAILING ADDRESS 3. LENDING INSTITUTION ' 'PHON~ 4. REALTOR/AGENT I J PHONE .. MAILING ADDRESS STREET LOCAT,ONd.~3a "//J. 7,3 >2 ,~ e c/ 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [] Four [~/SING LE FAMILY [] Two [] Five [] MULTIPLE FAMILY ~ Three [] Six [] Other 7. WATER SUP~J.Y ~ INDIVIDUAL* *ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM [~INDIVIDUAL/ON-SITE** **If individual/on-site, give installation date tOt--tOt If system is over two (2) years old an adequacy test is required [] PUBLIC UTI LITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [~ SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY I-~' INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER I-~IIN DIVIDUAL/ON -SITE DATE ~NSTALLED [~ PUBLIC UTILITY Connection Verified INSTALLER E~'Septic Tank or [] Holding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4.' DISTANCES Septic/Holding Tank Absorption Area ISewer Line I Nearest Lot Line WELL TO: Absorption Area to nearest Lot Line 5. COMMENTS ~E~'APPROV ED FOR ~-~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY (Title) LE~L DESCRiPTiON 72-010(Rev. 3/78)