Pump InstallatiOn Log
Well Drilling Perm,
. r NurnLer:
Parcel Identification lNuniber:
A
pump Usta at :Z� V
.e
PUTUP Intake Depti, pop of V , y - *-,I; Casing;
PunT 11'13nftfacturer`s Name.
PUMP Nfodel: q_S 0. 1
Pump Size / 'b P
Pitless Adapter- 13urial,D�,ptil: /14 flet
PitlesS Adapter
Pidess Adapter Tnstaller:
Well Disinfected Upon, C0,11ple'tjon?
Method of Disinfection:Q'Yes No
Comments-
PtiraP .installer Name,
Date of issue:
Pr Pertyowper_ —1we& Address:
A0 A
p.1
Attention: Tile RUMP instalie. SF1 '1 provide a yj;,,rtp iystaijatj
en ,09 to .ire DED withi*7,, 30 days of ptImp irlstalh-%,jor,
Municipality of Anchorage Page 1 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW980069 PID Number: 051 -13:?-13
Name: ~¢JM&[vI Contracting Wastewater System: ~New [] Upgrade
Address: P.O. BOX 670495 Chugiak, AK ABSORPTION FIELD
Phone: 688-1236 Cf Bedrooms:
rt~ [] Deep Trench ~Shallow Trench ~ Bed ~ Mound D Other
L E G A L D E S C R I P T I O N Soil Rating: Total Depth Irom ~iginal grade:
1 . 2 GPD/S~. Ft. 8
Lot: 5 Block: 2 ScZmitarSubdivisi°n: NO. 1 Deplh to p~pe bott0m4from original grade: Ft Gravel depth beneath4pipe
Township: Range: Section: Fill added above original grade: Gravel length:
- ~t. 38
WELL: ~New Q Upgrade Graveldepth: ~ Ft. Number of lines:, 1 Distance ~tw~n lines:_ Ft
Private 400 Ft. 80.56Ft 380 sO.R ASTM D3034 PVC
Driller: Su 11 ivan Date Drilled: Static Water Level:Installer: Date installed:
5/1 5/98 78 Ft.I MM&M Contracting 5/12/98
i Yield: . 2 2 GPMGPM Pump Set at: Ft. Casing Height~bove Ground: :Ft. TANK
SEPARATION DISTANCES ~o u Holding ~ S.T.E.P.
From Tank Field Slation Tank SewerLines Anchorage Tank 1 , 000
wel{ > 100 ' > 1 00 ~ H/A N/A N/A Material: Numberof Compa~ments:
Steel Two
SudaCewater>100' >100' $/a N/A N/A LIFT STATION
Lot > 5 ' > 1 0 ' N/A N/A N/A :Size in gallons:Manufacturer:
Line
Foundation > 5 ' > 10 ' N / A N / A N / A "Pump on" level at: "Pump off" lev;I, at: High water alarm at:
CudainDrain Non8 ~n Lot Pump Make & Model Electrical Inspections pedormed by:
Remarks: Blas BENCH MARK
Bladder containing approximately Location and Description:
Garage Slab
1 ,000 gallons of static water storag,
located in the crawl space of the J AssumedElevation:100
house.
Inspections pedormed by: sE* Dates' 1st 5/12/98~~% ~~
Department of Flea[~ and Human Se~ices approval ~;~ko
Reviewed and approved by: ~ ~ Date' ~-/~* ¢~
Municipality of Anchorage Page 2 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P,O. Box 196650 Anchorage, AK 99519-6650 - 343-4744
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number SW980069
PID No. 051-132-13
S1 23.8
C3/37.0 66.0
/64.5186.o
C4/64.5
Mt 186.0
~'-~ .~S 1
1 ,000~. S2~<~Alternate
Gal~ .on ~C3~ Site
Septic TanR ~ ~ic ~n~ ~
C~
, ~ ~8 ' Long X
k 5 ' Wide X
Effective
~ Trench
/
PLAN AS-BUILT
SCALE 1" = 30'
0sorption
Municipality of Anchorage Page 3 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 Anchorage, AK 99519-6650 - 343-4744
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number SW980069
PID No. 051-132-13
I:
5
~ 98.8~ OO
31 .7' 10.1 '
PROFILE AS-BUILT
HORIZONTAL SCALE 1" = 10'
NO VERTICAL SCALE
by
DOC Co. dba
SULLI VAN WATER WELLS
P,O, BOX 670272, CHUGIAK, ALASKA 99567 · TELEPHONE 688-27~9
OWNER OF LAND ./~
LEGAL DESCRIPTION ~e.~,..t4~~&~.. .
PERMIT NUMBER~ Date of Issue_.~-
TAX INDENTIFICATION NUMBER O'~'"//
Is well located at approved permit location? ¢ [~ No
Method of Drilling: ~ary [~ cable tool
Depth of walk '~O~
Casing Type _.~l~_~.~Wall Thickness
Diameter ~ # __inches, depth
Liner Type: ~,~.~'
inches
//
feet
Casing Stickup Above Ground:
Static Water Level (from ground level): '~'
Pumping level: .~feet after hrs. pumping__
Recover Rate: o ,¢, ~ g pm
Method of Testing:
feet
feet
.gpm
Well intake Opening Type:
[~ Screened; Start
j~;},-P~rforations Start '7_.~_
Grout Type: ~",,~ '/'~,'~.
Depth: from
Pump Intake Depth: __
Pump Size __ hp
Well Disinfected Upon Completion?
Method of Disinfection;
Open End ~:~.epen Hole
feet Stopped feet
feet Stopped ~O feet
Volume
feet, to
Brand Name
~ Yes [~ No
feet
feet
Comments:
BORE HOLE DATA
DEPTH
RFCEL\/ED
APfi 8
M~nicipahty ol
Oept, Health & Human Services
ATTENTION: It is the responsibility of the properly owner to submit a copy of the well Icg to the proper authority, Municipality
of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation, MatSu Borough:
Department of Environmental
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW980069
DESIGN ENGINEER:ANDERSON ENGINEERING
OWNER NAME:KRAMER WILLIAM ALAN &
OWNER ADDRESS:
DATE ISSUED: 4/21/98
EXPIRATION DATE: 4/21/99
PARCEL ID:05113213
LEGAL DESCRIPTION:
SCIMITAR #1 BLK 2 LT
LOT SIZE: 54250 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
THE ATTACHED APPROVED DESIGN.
ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80).
THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
MEMORANDUM
DATE: May 11, 1998
RE, CEIV[D
TO: Donna Mears
FROM: Mike Anderson, P.E. 2'4/I
1998
Municipality of Anchorage
Dept. Health & Human 8orvices
SUBJECT: Lot 5, Block 2, $chnitar Subdivision No. 1
Permit No. SW980069
The owner of Lot 5, Block 2, Scimitar Subdivision No. 1, along with his well driller, has
decided the ideal location for the new water well is in the northwest corner of the lot.
Unfortunately, this is the area identified for the primary septic system. We have, therefore,
resdesigned the system and placed it in the southwest cornet' of the lot outside the I00'
protective radius of the new well location.
A testhole was placed in the area of the new absorption trench and conditions were found to
be identical to those found in Testhole No. 2. Clean well graded gravel was found at 4'
below the surface. This material percolates at rates near 1 ~rdnute per inch. Since more
than 50% of the material passes the No. 4 Sieve a sand filter is not required. The size of
the system will be identical to that originally designed and permitted for the other side of the
lot. The alternate site remains in the same area.
We hereby request the well and septic system permit previously issued for this lot be
modified to allow placement of the well and septic system at the locations shown on the
attached site plan. All other aspects of the original design and application package remain
unchanged.
Please let me know if you have any questions.
LOT 5, BLOCK 2, SCIMITAR NO. 1
Well
J
_SSITE PLAN
SCALE 1" = 50'
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR: William Kramer
LEGAL DESCRIPTION: LOt 5, Block 2,
~L_ Scimitar No.
1 _
2
3
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20,
COMMENTS Material similar to
prior to test.
Township, Range, Section: ....
WAS GROUND WATER
ENCOUNTERED?
1 SLOPE SITE PLAN
IF YES, AT WHAT
DEPTH?
Depth to Water After
Monitoring?
Reading Date
GROSS
Time
Depth to
Water
z.'/¢ ',
7 '/~"
~ '/~
Net
Time
PERCOLATION RATE / Im,nute~',nchl PERC HOLE DIAMETER ~ ~.___~_~
TEST RUN BETWEEN '--~ FT AND ~ .__ FT
Testhole No. 2. Test cavity presoaked
Drop
I ,/- TIFY THAT T IS ?EST WAS P[RFORMED IN
72-008 (Rev, 4/85) I
April 4, 1998
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject:
Lot 5, Block 2, Scimitar Subdivision No. ¢\
Septic System Design
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
We hereby apply for a permit to construct a well and an onsite septic
system on Lot 5, Block 2, Scimitar Subdivision No. ll~. The attached site
plan and backup documentation identify the size and location of the well
and new septic system to serve the three bedroom home to be constructed
on the lot. The 100' protective radius for the well is also shown on the
plan.
The surface of the back quarter of the lot slopes dramatically from east
to west at slopes exceeding 30%. The slope flattens however to near zero
where the house will be placed and the septic system constructed. A
testhole placed in this area revealed a gravelly silt which percolated at a
rate of 12 minutes per inch. Another testhole placed closer to the front of
the lot consisted primarily of well graded gravel which percolated at a
rate less than a minute per inch. The majority of the material passes the
No. 4 Sieve. The primary absorption trench will be constructed in this
area with a service line running from the septic tank. The ground surface
in this area is fairly flat and the absorption trench will be constructed
paralell to the tot line.
No conflicts exist between the new septic system and the protective radii
of adjacent wells. Similarly, no conflicts exist between the new well and
the separation distance from septic systems in the area. The only close
system is to the south and is more than 100' from the proposed well.
Lot 5, Block 2, Scimitar Subdivision No. ~
April 4, 1998
Page Two
If the system is constructed as designed the following statements apply:
The system, if constructed as designed, will have no adverse impact
on the wells in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact
on existing septic systems in the area or those to be constructed in
the future.
The system, if constructed as designed, will have no adverse
impact on reserved space, either surface or subsurface, on any lots
located in the area.
The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area. The current drainage pattern will
be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
IS PROJECT!
/ /
/
/4
/
/
/
/
/
IZ
11'
EA MAP
SCALE 1" = 100'
/
/
LOT 5, BLOCK 2, SCIMITAR NO. ~i
40
1,000 Gal
Septic Tank
X
X 5' Wide
~fective Depth
:ion Trench
~nate
Well
SITE PLAN
SCALE 1" = 50'
EN 15 (10/78)
LOT 5, BLOCK 2, SCIMITAR SUBDIVISION
NO.
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Three Bedroom Home
Perc. Rate: LT 1 Min./Inch
Application Rate: 1.2 GPD/SF
5' Wide Trench System
1,000 Gallon Septic Tank
4' Drainfield Rock
3 Bedrooms X 150 GPD / 1.2 GPD/SF = 375 SF of Absorption Area
375 SF/5 LF (Width) X .5 (Red. Factor) = 37.5 LF Trench Length
Therefore: Construct a 5' Wide Absorption Trench System With
Lateral 40' in Length with 4' of Drainfield
Distribution Pipe in Trench Placed at 4.0'
Surface,
One
Rock Beneath the Lateral.
Below the Original Ground
qLO"
NOTE:
~///~ ~'/// ,,~-/// ,.,,~./// ~.~///
TYPICAL WIDE TRENCH SECTION
Grade Area Over Trench to Drain Away.
Minimum 3' of Cover over Septic System.
Minimum 4' Separation From Groundwater.
Minimum 10' Separation From Lot Line,
PERFGRMED FGR:
lEGAL DESCRIPTION:
.1
2-
3
4
9
1i
14
16
18
William Kramer
~ot 5, Block 2.
ScimitarNo.---~'--~~
OL.--
I
.. \.\e
WAS GROUND WATE~No
.. E
~. ~one 1~1=4 / 4 / 9 8
IF YE~ AT WHAT
ACCORDANCE WZI'~ A, , ~'~ ..................
I'~OOLAllON RATE ,,,/~'
" Im~'l~-~'~'-m¢t3) PE~IC HO~ D~M~ ~ "' ' ....
~ RUN ~ ~ ~ ~D ~ ~ . '
Testhole presoaked prior to tes~ - ' ...
, ~1~-
~GAL DF..~=RIPTION:
.1
2
14,
~7
William Kramer "" DA~ ~ ~ ...........
~ot 5, Block
Scimitar No.
.- -
.*
GROUND WAT'"~ NO ....
,,'"¢-.3 I I I '1
IF YE~ AT WHAT L:
TesthOle presoaked prior to test.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 5, BLOCK 2, SCIMITAR SUBDIVISION NO. f~ \
GENERAL:
1. The scope of this project includes furnishing and installing
a new 1,000 gallon septic tank. It also includes the
construction of a new 40' total length by 5' wide by 4'
effective depth absorption trench. The distribution piping
must be placed at 4.0' below the ground surface. Mounding
over the trench may be required to provide a minimum of 3'
of protective cover.
2. Construction shall be in accordance with the approved site
plan, design drawings, Municipal Permit with any special
provisions or conditions, and all applicable State and
Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all
underground utility locates and for the layout of the septic
system and verification of the location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall
be responsible for final grading areas subsequently
depressed from soil settling. Property owner shall be
responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must
be certified by the Municipal Department of Health and
Human Services for system installations. Owners installing
their own systems must receive prior approval from D.H.H.S.
before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,000 gallon septic tank must be procured from an
approved source and installed at the location shown on the
plans.
Lot 5, Block 2, Scimitar Subdivision No. t~ \
April 4, 1998
Page Two
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts
for pumping access.
3. The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of
12 inches above final grade.
5. Tanks installed without 4' of cover shall have a minimum of
2" of direct burial insulation.
6. A foundation cleanout shall be installed one to four feet
from the building foundation. Two cleanouts are required
between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive
slope exists away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown
on the design. The bottom of the trench shall be within 2"
of level.
2. Distribution piping must be placed level with perforations
down atop a level bed of drainfield rock. Rock should then
be placed over the pipe to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between
the drainfield rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the
locations shown on the design. The portion below ground
must be perforated.
Lot 5, Block 2, Scimitar Subdivision No. ~. \
April 4, 1998
Page Three
5. Contractor shall verify the septic tank and drainfield are a
minimum 100' away from any private water wells in the
area, 150' from a Class "C" Well or 200' from any community
well.
6. Direct bury insulation must be placed over the distribution
system if less than 3' of backfill depth is available. Finish
grade over the trench must be mounded to prevent
settlement or depressions.
7. Grade area surrounding the absorption trenches to drain
away.
8. A minimum 2' of accepting soil is required below the
drainfield rock for a 5' wide trench. Contractor shall verify
this condition prior to placement of the rock. All pockets of
unacceptable materials must be removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a Municipally approved
septic tank manufacturer.
2. The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C.
(perforated and solid), ASTM F810 or H.D.P.E. (perforated,
but not solid) and ASTM D2662 or A.B.S. (perforated and
solid).
3. Insulation shall be at least 2" thick extruded direct burial
polystyrene (Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted
watertight couplings (Caulder, Fernco, or equal).
with
Lot 5, Block 2, Scimitar Subdivision No. ~\
April 4, 1998
Page Four
5. A permeable geotextile fabric (Typar, Mirafi or equal)must
be installed between the final drain rock layer and the
native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than
3% passing the #200 sieve.
INSPECTIONS:
A minimum of two inspections are required by Municipal
Ordinance. These inspections must be conducted under the
supervision of a professional engineer registered in the State
of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation
of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement
of the geotextile fabric, gravel, distribution piping,
standpipes, cleanouts and insulation. No backfill should be in
place at the time of inspection.
Contractor shall provide acopy of all field survey layout and
construction notes for use in preparing the certified as-built
of the completed system.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # 051 -132~13"
1. GENERAL INFORMATION
Complete legal description
Lot 5,
Block 2, Scimitar Subdivision No. 1
Location (site address or directions)
Property owner ~4~.1~4 Con~-racbLD. g Day phone 688-1 236
Mailing address P.O. Box 670495 Chugiak, AK 995,57
Lending agency Day phone
Maiiin_g address
Agent ,Day phone
Address -
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
NOTE:
Two (2)
Individual well xxx
Community well
Public water
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
XXX
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Re,,'. 1/91) Fronl MOA #21
o
STATEMENT OF INSPECTION BY ENGINEER
AS certified by my seal affixed hereto and as of the validation date shown below, J verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/orwastewater disposalsystem is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein, lfurtherverifythatbasedontheinformationobtainedfrom
the Municipality of Anchorage flies and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection,
Name of Firm Anderson Engineering Phone 522-7773
Address P.O. Box 240773 Anchor.age, AK 99524
Engineer's signature ~Y/~c'~-(,,~--~-c(~- C~¢,~L~ Date 4/27/99
DHHS SIGNATURE
Approved for ~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-025(Rev. 1/91) Back MOA~21
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
· · -4744
825 L Street, Room 502 · Anchorage, Alaska 99501 (907)__~,~ic~pahty
Oept. Health & Human Services
Health Authority Approval Checklist
Legal Description:
A. WELL DATA
Well type Prlvate
Log present (WN)
Total depth 400 '
Sanitary seal (Y/N)
Lot 5, Block 2, Scimitar No. 1
Pamel I.D.:
051-132-13
IfA, S, or C, attach ADEC letter. ADEC water system number
Date completed 5/15/98 _
Cased to 80,5 ' Casing height (abow,~ ground) 2 '
Y Wires properly protected (Y/N) Y
FROM WELL LOG AT INSPECTION
[)ate of test 5/15/98
Static water level 78 '
Well production ,22
WATER SAMPLE RESUUrS:
Coliform 0 Nitrate
Date of sample: 12/17/98
B, SEPTIC/HOLDING TANK DATA
Date installed o-_%~98 Tank size
Foundation cleanout (Y/N) Y
Date of Pumping New Pumper
g.p.m, g.p.m.
2.67 ~/L Other bacteria
Collected by:
C. ABSORPTION FIELD DATA
Date installed 5/1 2/98
Length 38 ' Width
1,000 Number of Compartments 2 Cleanouts (Y/N) Y
Depression (Y/N) N High water alarm (Y/N) N
Construction
Soil rating (g.p.d./ft~ or fF/bdrm) 1,2
5 ' Gravel thickness below pipe
Effective absorption area 380 SF Monitoring Tube present (y/N) Y
Date of adequacy test New Const, Results (Pass/Fail) Pass
Fluid depth in absorption field before test (in.);
Fluid depth (ins) Minutes later:
Peroxide treatment (past 12 months) (Y/N) N
72-026 (Rev. 3/96)*
System type 5' Wide Trench
4 ' Total depth 8 '
Depression over field (Y/N) N
For Two .bedrooms
Immediately after____ gal. water added (in.):
Absorption rate = .g.p.d.
If yes, give date ~/A
D. LIFT STATION - None on ~ot
Date installed Size in gallons.
Manhole/Access (Y/N) "Pump on" level at* _
High water alarm level at* *Datum
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot. GT 100'
Absorption field on lot GT 1 0 0 '
Public sewer main N/A
Sewer/septic service line. G't~ 2 F, '
On adjacent lots
On adjacent lots
"Pump off" level at*
GT 100 '
GT !00'
Public sewer manhole/cleanout N/
Lift station N / A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation GT 5' Property line CT 5 ' Absorption field__ GT 5'
Water main/service line GT 1 0 ' Surface water/drainage ._G.T 1 0.Q2 Wells on adjacent lots G?. ! 0 0 '
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
CT I 0 ' Building foundation c.m I n ' Water main/service line GT 1 0 '
GT 10'
Property line
Surface water GT 100'
Curtain drain N~n~ on T.ot
ENGINEER'S CERTIFICATION
Driveway, parking/vehicle storage area
Wells on adjacent lots
I certify that I have determined thru field inspections and revie
in conformance with MOA HAA guidelines in effect on this date.
Signature "~'~'~b~ (~'~4'-4¢-"~
Engineer's Name Michael E. Ander.~cm; P- E.
GT 100'
Date
4/27/99
HAA Fee $.
Date of Payment __
Receipt Number
72.026 (Rev. 3/96)*
Waiver Fee $
Date of Payment
Receipt Number
April 27, 1999
MM&M Contracting
P.O. Box 670495
Chugiak, AK 99567
Attention: Paul or Arlene
RECEIVED
APR 28 1999
Municipahty o~ Ar,(;i~orage
Copt. Health & Human ,Services
Subject: Lot 5, Block 2, Scimitar Subdivision No. 1
Well and Water System Flow Test
Dear Paul and Arlene:
We recently completed a flow test on the well and water system located on Lot 5, Block 2, Scimitar
Subdivision No. 1 to determine the total capacity of the system and the production rate of the well.
The well is 400' deep with a static water level of 78.67'. During our test to determine the storage in
the well the water level drew down to 388' before the pump shut down. The well casing therefore
provides nearly 310' of water storage or approximately 452.7 gallons.
The Kolaps-A-Tank Bladder in the crawl space along with the Gould ½ HP Transfer Pump and
WX-250 Pressure Tank are capable of storing nearly 830 gallons of water based on our flow test.
The total storage capacity of the system is therefore 1,282 gallons of water. This total equates to
5.34 gallons per minute when totally discharged over a 4 hour period.
The flow test perfm~ed on the well indicated a production rate of .238 gallons per minute which is
nearly identical to rates achieved in the past. The Municipal requirement for a two bedroom home
is a production rate of .208 gallons per minute. The well meets the Municipal requirement for a
two bedroom home.
In summary, the well production rate is .238 gallons per minute. The water system has a storage
capacity of 1,282 gallons of static water storage when including both water stored in the casing and
in the bladder and tank in the crawl space. The system therefore meets Municipal requirements for
both production and storage.
Sincerely,
Michael E. Anderson, P.E.
08:29 FEO)~-CTE EIIVI RON~NTAL
Drinking Water Analysis Report for Total coliform Bacteria
AnalyStS shoWS ,~his 'Waucr SAMPLF- w
READ, Sansf~c~oD'
O pUBLiC W ATI.ZB. syST~'M I'D' ;? ~ {3 Sample over 30 hours old, TcsultS m~Y
!jns~usf~torY
r~ pRIVATE WAT£~ts¥STRM ~ 0 ~ unte~lc
~~ Invo~ 1~ ~n u~si~; ~pl~ sho~lld
~ 0 5e~ ~ . lc ~ ~ ~n~uon
to ,ud~c~ ~. s~al de~xv~
Me, boO: ~- M~nbrmme Ffi~
· ~,~,~ mi. --~s~
' Result' An~*~
SAMPLE ~PE: ~ Trca~ Water
~ Routlu~ s~m~lc o Uutrt~ttd Wa~r D~: ~ ~ ~"~ ~ ~-
~peat Sample ifor rouOnc
0 with lab rcf, no, ~ ~ Cllen{ notifl~ of un~atisfacto~ r~ults:
Co;l~ [
Colt~ By Phon~
SAMPLE LocATION
MMO-MUG
BGB
verification: LTB
Final Mzmb~ut Filer R~u[~
Co rnr~e'fl t,$:
DE¢-Zg-98 0B:Zg FRO~-CTE ENVIRONMENTAL 551S301 T-Z§O P.O,/us
ZI~ CT&E Envlronmen~al Services
· ~
CT&E ReLa 987273003
Clien~ Name Andr.~on Engineering
Cl~em Sample ID Lot 5 Block 2 Scim~ ~
M~x Dr~kiug Wa~er
PWSID o
Sample Rema~-g:
Client PO,~
Primed l>ale/Ttme 12/28/98 12:26
Collecte~i Date/Time 12/17/98 13:55
L~ceived ])a~e/Time 12117198 16:25
Technical Dh't~tor: Stephen C. Ede
~L
0.100 ~j/L
co~/lO0~t
EPA 300.0
10 ~e~
12/17/98 $¢L
12t17198
~.!/? '?