ON -SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP231090 PID Number: 015-062-42
Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ■❑ Upgrade
Name
Karl and Mary Schopen
ABSORPTION FIELD
9 Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
7121 Candace Cir, Anchorage, AK 99507
❑ Other
Phone
Number of Bedrooms
Soil Rating
JTotal depth from original grade
3
0.8 GPD/SF
12.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
5.2 Ft.
Gravel depth beneath pipe
•$ Ft.
Subdivision Block Lot
Silver Crest 2 11
Fill added above original grade
0.5 Ft.
Gravel length
41.0 Ft.
Township Range Section
Gravel width
3.0 Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
1
Dist. between trenches
From
Tank
Field
Tank
Line
598 Ft2
N/A Ft.
Well
>100'
>1 00'
N/A
N/A
>25
TANK❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Greer
Capacity
1250 (Upsized) Gal.
Surface Water
> 100'
>100'
N/A
N/A
Material
Plastic
Number of compartments
2
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
> 10'
> 10'
N/A
i N/AtfF-T--STATION
Manufacture
Capacity
Remarks *Depth of septic tank during installation
Gal.
limited final trench depth
Alarm location
Electr tailed by
PIPE MATERIAL House to tank D3034 Tank to D3034
drainfield
Installer
A.C.E.S.
Drainfield D3034 CO/MT D3034
Inspector L.Tidwell
BENCH MARK (Assumed elevation) 100 ft
Inspection 15t 5/15/23 5/16/23
Location and description
dates: 2°
Back Door Threshold
s'd 5/16/23 4`h
ON -SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
-- OF i
Conditional Approval: Date
r •'9cA l�
o*:49 H •*
Septic System
Approved DateI2 2p Z
Be�CE92iller
y +���'�fF�• 1/16/24
Note: this approval does not include well requirem.
il�iPROFESSlO��
permit
O\\ate
(Rev Ub/U2/18)
SILVER CREST, BLOCK 2 LOT 11
PERMIT # OSP231090 P I D # 015-062-42
LOT 8
LOT 12
500
510
� / / _ � � — J � 41' LONG x 3' WIDE, 6.8'
520
EFFECTIVE DEPTH ABSORPTI {
/ 530 �- TRENCH
540
r C01--------- ' CO2 —
MT1 TH#1 'I EXISTING DV
TRENCH </ j
2C0 - SV /
® M<t% B
A
1250-GAL SEPTI WELL
TANK
I
LOT 10
WELL
I
r /
i r
WELL
0\�� A B LEGEND
�4
497H ••••:*nor PLAN AS —BUILT
•
•
Benja• i Schiller : 0 p 50 100
�d ���••• CE 2592
:.16,24••,.�AW' FEET
MH
18.1
54.1
SV
23.0
54.6
2CO
24.4
54.5
DV
25.7
54.2
C01
43.2
62.3
MT1
41.6
58.9
CO2
54.9
28.1
MT2
55.6
29.1
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH- MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
SILVER CREST, BLOCK 2 LOT 11
PERMIT # OSP231090
P I D # 015-062-42
o1-- �o
97.7 FINISH GRADE 97.2 ORIGINAL GRADE U
HII fill
92.0
DRAINFIELD ROCK
85.2 85.2
41'
NO GROUNDWATER 5/4/23
= 79.2
I—
ENGINING
PROFILE AS -BUILT
(NO SCALE)
92.0
�60
49 —
.
• • • • • Benja in Schiller
I F CE 12592 `� s
1/16/24
DEPTH
(feet)
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
'.r
1.,
GE SOILS LOG AND PERCOLATION TEST
E N G I N E E R I N G
LEGAL DESCRIPTION: SILVER CREST B2 LII
PERFORMED FOR: KARL & MARY SCHOPEN
DATE: 4/20/23 PARCEL ID#: 015-062-42
TEST HOLE 1
1' OB
PERC TEST LOCATION
GM (SILTY SANDY GRAVEL)
f:
TEST HOLE DEEPENED
ON 5/15/23
DATE
READING
START TIME
NET TIME
(MINUTES)
DEPTH To
WATER
NET DROP
(INCHES)
INCHES)
4/20/23
1
11:09
30
0
51%6
51%6
2
11:40
30
0
41 %s
413/16
3
12:11
30
0
41%6
4'%6
PERCOLATION RATE: 6.4 (MIN/INCH)
SITE PLAN
TH I
YES WAS WATER ENCOUNTERED?
17.5 IF YES @ WHAT DEPTH?
DRY DEPTH TO WATER AFTER MONITORING
5 /4 /23 DATE OF MONITORING TECHNICIAN: L. T I D W E L L
5/23/25 (CONFIRMATION)
COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED. TEST HOLE DEEPENED DURING
CONSTRUCTION.
PLOT PLAN —__ AS BUILT —X_ SCALE _1"=_ 60' _ GRiD _ SW 2439 Project No. 23-122VA2
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, inc. (907) 522-6476 Phone
ken®langsurvey.com
Professional Land Surveyors jonothan®langsurvey.com OF At,
�l 1
I trovisOlongsurvey.com ,� �'� • ' " ' " 's�`�
I hereby certify that I have surveyed the following described property:
LOT 11, BLOCK 2, SILVER CREST SUBDIVISION (PLAT No. 77-176)
Anchorage Recording District, Alaska, and that the improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on said property except as indicated hereon.
Dated this the --'4, � ��'n Day of i"E �`' ' ____ � =�=�' ��'_, at Anchorage, Alaska
It is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat.
co TH
. 48_
�� •,. KENNETH G. LANG ,•o
cal . o. 5202
Ess[0N
State of Alaska AECC963
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP231090
Work Type: Septic Upgrade
Tax Code Number: 01506242000
Site Legal Address: SILVER CREST BLK 2 LT 11 G:2439
Site Mailing Address: 7121 CANDACE CIR, Anchorage
Owner: SCHOPEN MARY K & KARL P
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
��»cn
o .5',
U
Department
5/11/2023
5/10/2024
51945
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: I �V `�-� 10 f C7
7
Issued By: >_
Date:
Date: 5 1i1 / 2 3
3
MUNICIPALITY OF ANCHORAGE
�r
Community Development Department s'- r= Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 015-062-42
Property owner(s) Karl and Mary Schopen Day phone
Mailing address 7121 Candace Cir, Anchorge AK 99507
Site address 7121 Candace Cir
Legal description (Sub'd., Block & Lot) Silver Crest B2 L11
Legal description (Township, Range & Section)
Lot Size 51,945 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Fieldx❑
Initial ❑ Single Family (SF) ❑x
Septic Tank x❑
Upgrade x❑ (w/wo AD U)
Holding Tank ❑
Renewal ❑ Duplex (D) ❑
Multiple Dwellings ❑
Privy ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 5 3 pS Waiver Fees:
Date of Payment: 0 2 3 Date of Payment:
Receipt Number: Receipt Number:
Permit No. 0-32 2 3 10 y D Waiver No.
Permit App_ % : • !—'.,:c
May 10, 2023
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Silver Crest B2 L11- 7121 Candance Cir.
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot has a septic system that is nearing its end of useful life. We are
submitting this permit application for the construction of a new septic system. The attached site
plan identifies the location of the home as well as the existing and proposed septic locations. No
conflicts exist between this proposed system and any other well or septic system, whether on this
lot or adjacent lots.
The ground surface on the lot slopes down toward the north of the lot at grades around 30-40%,
but near the proposed septic system location slopes are mild. The steeper slopes, greater than 25%,
start more than 50 feet downslope from the trench, and the design also meets the criteria for
trenches built on steep slopes. Contours are shown on the site plan showing the grade and direction
of flow. Stormwater drainage will not impact this septic system. The new trench will be
constructed parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The proposed trench is
located more than 14’ away from the existing trench.
Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design
is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231090, Curtis Townsend, 05/11/23
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
41' LONG x 3' WIDE, 7' EFFECTIVE
DEPTH ABSORPTION TRENCH
ENSURE 14' SEPARATION FROM
EXISTING TRENCH
1000-GAL SEPTIC
TANK
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
CO
MT
TH#1
PID # 015-062-42
SILVER CREST, BLOCK 2 LOT 11
FEET
0 50 100
CAND
A
C
E
C
I
R
C
L
E
3-B DRM
H
O
M
E
545
SEPTIC PLAN
5/4/23
540
530
520
510
500
EXISTING
TRENCH
DECOMMISSION
EXISTING TANK
PER U.P.C.
MT
CO DV
2CO
WELL
WELL
WELL
2CO
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231090, Curtis Townsend, 05/11/23
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
3'
6"
2'-6"
7'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: 6.4 MIN/IN
APPLICATION RATE: 0.8 GPD/SF
7.0' DEEP TRENCH SYSTEM
1000-GAL SEPTIC TANK
BOTTOM OF TRENCH: 10.0' BELOW GRADE
FLOW LINE ELEVATION: 3.0' BELOW GRADE
TOP OF TRENCH: 0.5' ABOVE GRADE
450 GPD / 0.8 GPD/SF / 7.0' DEEP / 2 SIDES) = 40.2 LF TRENCH REQUIRED (41.0 LF SPECIFIED)
GEOTEXTILE FABRIC
6"
5/4/23
ADD ADDITIONAL FILL
OVER MOUND TO
ENSURE ADEQUATE
COVER AFTER
SETTLEMENT
SILVER CREST, BLOCK 2 LOT 11
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231090, Curtis Townsend, 05/11/23
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING START TIME NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
WAS WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING
IF YES @ WHAT DEPTH?
6.4
4/20/23 1
2
3
GM (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
NO
SILVER CREST B2 L11
5/4/23 015-062-42
KARL & MARY SCHOPEN
11:09 0
11:40
12:11
1' OB
30
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: L.TIDWELL
5 10 16
N/A
DRY
5/2/23
COMMENTS:
SITE PLAN
510 16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
5/4/23
0 30 4 12 16 412 16
0 30 4 1116 41116
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231090, Curtis Townsend, 05/11/23
rcniuncc nnc nrrnunmni c.
PLOT PLAN ___ AS BUILT X_ SCALE _1= 60__ GRID _ SW 2439_ Project No.
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, i n c . (907) 522-6476 Phone
kenOlongsurvey.com
Professional Land Surveyors jonothanOlongsurvey.com OF At \l 1
frovisOlangsurvey.com 'C� • qS 1 ,
I hereby certify that I have surveyed the following described property: /c.'
LOT 11, BLOCK 2, SILVER CREST SUBDIVISION (PLAT No. 77-176) 49TH
Anchorage Recording District, Alaska, and that the Improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed / • •
premises and that there are no roadways, transmission lines or other visible KENNETH G. LANG ; o
easements on said property except as indicated hereon. �+�c 0.5 02
Dated this the _ '%__ Day of ___� 1'i = __. at Anchorage, Alaska F p • • �D r
1 F9O � Z
�l\ AOEESSJ% t
It is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat. State of Alaska AECC963
U ay 29 19 09:23a t",noho; age VVe11 cry futv-p :ger 9972430742 P.1
Development Services bepartment
W Building -acfety Givisi,:art
Wat r & Wastewater Pro
r�ram s
1700 1`i.'11C{^8 la(�Cd ^(°
- p, i, Box 19665,9
MayC:•
lv7 o- 9950-1 Anchorage,AK < '
y rt i E 7 Y f
1V:Vl^: til;lrt,Cf`gfC jtg ,"/
t90?1343-7904
Pump Installati rl Log
Well .Drilling 1'ersni:t Vunioer: �W
ftrcel Ielealtifieation elnaiye1:_ � Q(�,Z_ y2
Legal i}eseriptioe{ ---
S i I V( -r- (,f' re S b 2 LI I
Pump 11l,taliatiQ-i1 }7j;,jte:--
..,./,�
PUMP intake Depth Below reap 01, WC -1l Fusin<�;
,2 a,
Pump ?vlanufactEaa er's Name: _
PIUMP Model: Il
.Pump Size hp
Pittess .Arl3ptar Burial Deptia: 12— feet
Pitless .Adaptej- Maunfaetnrer's Mime:
P;tless ,4dapter Iustailer:
"'ell Disinfected upol, CGn,pletj(),,? Yes C1 No
Mothod of Disinfeetl9fl:
C ommexts:
Late of
Issue:
Proper€y Owner tiI
Lae Address:
"
CA
I':Dmp Installc:s• IN:axne: �
i �j % ro ;ars,�a P `o
Attention: The pne:ip ii?St�l1�_ shrill piOyide a pt:r_z-i,.staliulit, a lob to Ti;. DSU i, i+.h: 30 day:; 1 psrct, i78ta`1 tion.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
PHONE
274-i300
II~NEW
E]UPGRADE
Neal Burleson
MAILING ADDRESS
3318 Iliamna Circle
LEGALDESCRIPTION
Lot 11, Block 2, Silvercrest Subdivision
OCATION
DISTANCE TO: Welll].0' Propose~ Absorption area
Manufacturer
Greer
Liq. capacity in gallons IF HOMEMADE: Ins de ength
Well Dwellin§
DISTANCE TO:
Manufacturer
I Well
DISTANCE TO: 120
No. of lines Length of each line
1 36'
Top of tile to finish grade
5'
Length
of crib
DISTANCE TO:
Class
DISTANCE TO:
Width
Crib diameter
Well
Depth
Building foundation
Foundation
32
Total length of lines
36'
Material beneath tile
Depth
Crib depth
Building foundation
Driller
Sewer line
10'
Dwelliog 12
Material
W dt~
Steel
IMaterial
INearest lot line
32
Trench width
36 inches
Gravel 84 inches
NO. OF BEDROOMS
3
PERMIT NO.
780774
No, of compartments
2
Liquid depth
PERMIT NO.
Liquid capacity in gallons
PERMIT NO,
780774
Distance between lines
Total effective absorption area
504 Sq.. Ft.
PERMIT NO.
Total effective absorption area
Nearest lot line
iPERMIT NO,
Absorption area(s)
Distance to lot line
Septic tank
OTHER
PIPE MATERIALS
Cast Iron/Plastic Perforated Pipe.
SOILTESTRATING
165 Sq. Ft./Br.
INSTALLER
H & M Excavatin?
REMARKS
APPROVED ~ DATE LEGAL
Block 2, Silvercrest subdivision
72-013 (Rev, 3/78)
I'"11::I?, iii I"11..11'"1 "l . t¥iE!: I::'t:' OF E:IiliI3,1:~:O(31'"IE; ..... i;i:
I"I'It!7 t.Ebl(31'll !)][ I'11::1",1S ]!] O1",1 ]1; ?:i; Tt"II!:; I...EJ",t(iiTH ( ]i I",! I:'E;li!YI' ) (31:::'
'l'l!fi! I)t:i:it:::'Tl'l Cfi::' I:':I "l'!;i:l(tl",!(31q O1:;i: i::'];T ii;ii:i; 'l'l'~lli!i; I]);I]STI:::II",I(3E I]i~lZ"l'l,.lt'El~i;t",l t~l"ll:ii] :!:i;I..ll;;?.l:::'!:::t(3tlii; (3i::: "t'l."lii!]
(!i!iiX31..IH, D I:::II~',!D TtlEi I:i',Oi'T()H (;~1:::' 't'Ht~ t::Y,:':X31:':I'v'I::I'I'' ;!; O1",1 ( ;I] i'.,I I:::'f!iEY'I' ).
'i'HI;l';:'.li!! ]7 i!i; t",10 SEYi" I,I ii; I')'I"H t::;'(]ll:;i'.
']111:'( ('~l::?.l:::l',,,'!ii!]!.. !)liii;F'TFI ;f'.'i:; "IHE I'"I];I'.,I;!]HI,.II"t 13,1iiT:"l'I'l (')1::' (i:il:;i:F:i'v'!ZI..
!:::llX!l') 'i111!:( F!IO't'1'(3i"1 (31:::' TI'Ill E]i:';X31:::I'v'I:::I"I'i1](;II",I (]7i",1
I::'!i!il:;;ff"t ]!] T t:::11:::'I:::'I.. ;i; (];1:::1t",1'1" HI:::!'.!]; 'l"Ht-:i; i,~'.l:i!i:!ii F':' ;i; ?'l'.!i; )i I:i!: i!i I ]; 'Ih" ~1(3 i!i I'.,!1:':'(]11-;i'.!'1 'T'I'I ;ii ~i; DEiI'::'t:::!I:;?.TI'"Ii!!(i",IT f'.:,t..1!:;;i ;I; !",!(3 "!"HIE
;!; I',!:iii; I"I::IIJ~.I:::IT ;!; Otq )] Iqi!ii;i:'f!X3"l~ ]; I']II',,IS (i F:ll',f"i" !,.1!i~!_,l..!]!; I":lD.3't';:l(31i!;!q'F I' yl 't1'1 '.ii '.iii I:::'1:;'. i]; f::'l:!!it:;?'l'V I:;II",ID
blI il"l!ii~li;l:;7: '" I:: .';;:l:ii2:::; .r !)l!i;l'.,!C;lii!iE; TI.II:::IT TI.IIZ !41:::1!...I.. 14 ~1] I..1 :,1::~., I ..
I::: I:::!1":I.::'t:::' Ii !..1 ii i'.,!1: 3I::' F:II',,I'.~.' .: .... '1:.1'1 14 ]] TI-1(31..I"I' I'::' ]1; I',,11:::11. ]1] I'.,!SF'I:!!X3T ]] O1',,I I::II'.,ID l:::il:::'P!:;i:(3'v'l:::ll., l!!?r' 'T'H ]7 ;!!!;
!)llii]r:'l:::ll';?.'l'l"lf!fl'.,IT I,,I ]1] t..[. 131:!ii ':~;I..ll!!kil'liX;;T T() I::'1::: ]i ',:] E;(':IJ F T '; I"J
I','I ); !'.,I )i HI..II"/ I) ]] STI:::II',,ICI!ii Iiiiff~:':i"l.dEE'.l',l I'::I I.'rlEi!.l. F:II"'ID !':'11'"!'¥' O1"11 ' '.!!i; ]i ' l" !: :' fii;Ei]l'-ll::l(iil!i I) ]i i!!i;F:'OSI'::II .. ;:i:;"'"i!i;'t"~]l"i
:'/.1313 I::'l!!iil:iilT 1'::'(3[;ii I":1 I::'I"ii];","I:::I"I'Ei 141!!11,.I--; O1::?,
;;t.!iliO FG ;:;'.O~3 I:'ET!Yi' 1:::'1:?.(31"1 I:::1 1::"1..1131 IfC I.'.lFi;f.!.. I)!:?1_"!;1",1!3';!i1",1(!i I..1t:::'()t",! 'l'l"lli; T'?'t:::'l:i!; O1::' F'I,.IE~I...i!iC !"I!!ELI...
!'IELI.. l..(3(:i!iil; F:I!'?.[E Iq'.li!Xi:!l--l;(l:;i:l:i!T;' F:II"I[)I"11,.1!i?f' I:!i"til I;i:IEI"I..II;'.t'"!!:iCD TCI "Fl'lliil Iii:'l]iil:::'l:::!f;i'."t"l"lfliil'"l'l' I.'I)iTI'I]]!"'I ;iii:!i':'
(31:::' 'f"I'IE I'lf::]l..t. C(31'"II:::'I--i!!iYI' ~1] O1'"!.
()'I' I'!EI:;i'. I:'~:fi!i(i;!1..! ]t] I';i'.li!!il"'ll. iiil'"l"!-l:i; I'"lf::l"d I:II:::'I:::'I..V. E;l:::'l:!!f3 iii F '.!] C;I::IT )'. (')lq'.!i; I::ft'"!1) (X)i'"f'.i:!;'i'I;?.IJC: I' ]ii (3!'"1 D ]11 l:::l(3f:;i'.!::ll"!E; i:::t1:;?.1:!!i
I:::I",/I:::I]]IJ:::iE"I.J'!i TO ]iI",!S;I..I!:;i:IiE I:::'l;';'.Cll:::'l!iiil:;il ]]I'"I:!?I'I:::I!--.I....I:::IT)-'()I"'I.
Lots 11 & 12
Block 2
Table
WO ~D10914
Logged By: O.M. }latch
Date: April 12. 1978
~th in Feet
From To
0.0 - 0.5'
0.5 - 7.0'
7.0 -
tl.0 - 16.0'
Soil DescrJ. ption
Brown Peat, Pt, damp, soft.
F-4, brown Gravelly Sandy Silt, ML, stiff,
NP, particles to 2"
F-4, brown Sandy Silt., ML, damp, stiff, NP.
F-l, brown Silt_y Sandy Gravel, GM, damp,
particles to 3"
Bottom of Test Hole:
Frost Line:
Free Water Level:
16.0'
0.5'
None Observed
4040 B S'I'REET ,/
ANCHORAGE, ALASKA 99503
(907) 278-1551
ApriZ 28, 1978
W,O, ~D10914
Grid ~2439
Mr. Mike Stephens
Stephens Construction
P.O. Box 3-3772 ECB
Anchorage, AK 99501
Subject:
Subsurface Investigation for Feasibility for
On-Site Sewage Disposal Systems
I,ots 1~, ~2 and 16, Block 2, Silvercrest Subdivision
and Lot ~, Block 1, SST Subdivision
Dear Hr. Stephens:
As requested we performed a subsurface investigation on the
four above referenced lots to determine their suitability
for placement for on-site sewage disposal systems. Thr~ee
test ho]es were placed on April 12 and 13, 1978. The holes
were drilled by Denali Drilling, Inc. The test hole's were
logged and the drilling supervised by Mr. O.M. Hatch, senior
technician/geologist with Alaska Testlab.
~ ~ holes are located <)n the adjacent figures !tl and ~;2.
The test ho]_e logs are included as Table A. It may prove
helpful in :i_nterpreting the data on the test holes logs to
review the standard explanatory informa{ion contained on
Sheets 1-3.
Once the test holes were drilled, they were cased with
s~otted p].astic pipe. About a week later the test holes
were checked for ground water intrusion into the h6les.
None had occurred. All three of the test holes were dry.
'Pl'~en on April. 25, 1978, the -test holes were filled with
water and left over night to saturat6d, A percolation test
was then performed the next. day, April 26, 1978, by refilling
-the holes and monitoring the rate at which the water fell. in
the holes at 10 minute interva].s fo].- a period of one hour.
The perco].ation rates based on this testing are as follows:
Lots 11 and 12, Block 2, Silvercrest --- 10 minutes/inch.
Lot 16, Block 2, Si].vercrcst Su};division -.- 5.7 minutes/inch.
Lot 1, Block 1, SST Stlbdivision -- 2 minutes/inch.
Mr. Mike Stephen
April 28, 1978
Page 2
We would caution the use of a percolation rate as fast as 2
minutes/inch in Lot 1, Block 1, SST Subdivision. It is our
experience that due to the clogging action of sewage effluent
that a more conservative design value be used in silty sands
and silts. They that have a tendency to clog. We would
reco~mnend a design value of 5 minutes/inch.
We hope this is sufficient for your present needs. If we
can be of further service or offer any clarification of any
data presented here, please do not hesitate to contact us.
Very sincerely,
ALASKA TESTLAB
Melvin R. Nichols, P.E.
Laboratory Mgnager
MRN:rb
12 o :+ X ',,
,,, ~9,~ ~ss.f, I/?'
i '"~ 1 4 'x ", \
,~c.'-~ '- 53,622 s.f.
....a .' <x"> :) ,h/, x6~ 51 , 510
~t.~/ ~ "~ X . , ~r .... ~--
49,449 ~ ~ .~. 'ZL~,,o o[ ~-f:,?'¥ ~, .¥~:~.~-~J 78 12
. ¥
" ~".~ ~',,,~,, '.~,.
1
.~/' -'"" ~,~. ."' ~ ,,~ 'A, · 45, 482 s.f. . .
'. 'k t' :...:;';'~
D I M 0 N D
-. Vid,,
M-W DRILLING, INC.
DRILLING LOG
Well Owner :, :i:~. ~,~ Use o£We]l
Location (address of: Township, Range, Section, if known; or distance main read
Size of casing
Static water level
Screen (
Depth of Hole
ft. (aboVe)
); Perforated (
Describe screen or perforation
Well pumping test at ~ :) gallons per (h6tir)
of drawdown from static level.
Date of completion
"{Y) feet Cased to '!.//! ~ ]!(Jfeet
(below) land surface. Finish of well (cheek one) open end (
).
):Z [;~..~i~ i~',:':ih'~h;~;',~;,u~ ;-i~m~ iO'~. ';. it i/~,
(minute) for ", hours with !
WELL LOG
Depth in feet from
ground surface Give details of formations penetrated, size of material, color and hardness
; TO ~ ;~
')i: TO ii (~,
i) TO !,! ',
TO
ir ?~I : : TO- ~ .'~.':¥~
~ i TO_ !/i
TO.
TO
__TO
TO
TO_
);
ft.
3 -- CONTRACTOR
MUNICIPALITY OF ANCHORAGE
DEPAR'rMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date
1. GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Applicant Name ; :~~ .Telephone:Home ~?~-~f26 Business
(c) Applicant is (check one); Lending Institution ~; Owner/~; Buyer ~ ' Other ~ (explain);
(d) Lending Institution __ Telephone
Address
(e) Real Estate Company and Agent
Address
Telephone
(f) Mail the HAA to the following address:
TYPE OF RESIDENCE
Single-Family~ Multi-Family__[]
Number of Bedrooms ~
Other
WATER SUPPLY
Individual Well,~ Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Oesite'~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (I 1i8,1)
ENGINEERING FIRM PROVIDING mlSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Healtll
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of i~/'~~
this inspection.
%,¢~,4~ Telephone
Name of Firm ------'---
Address ¢'~.. O '~
Date A~.~ L £~3~, / ~ ~O~
Approved fol' (?,".,'~_,¢-',~...bedrooms by u~ ~~- "';;}--Date
~.,- /~ ,- ~_~ / ,, / ....
Approved ~,~/ Disapproved Conditional
Terms of Conditiodal Approval
CAUTION
Tile Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent prolessional
engineer registered in tile State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11t84)
WELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720
MUNICIPALITY OF ANCHORAGI~
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
APR ;l 6 lgst
Well Classification "'~ ~ ~
Well Log Present (Y/N) _ y
Total Depth ._~1~'O Cased to
Static Water Level 1~O
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
If A, B, C, D.E.C. Approved (Y/N)
Date Completed ~/~( / 7~ Yield
I ~ ~/( Depth of Grouting
Pump Set At ,1~.'~
Sanitary Seal on Casing (Y/N)
'*/' Depression Around Wellhead (Y/N)
ioo~'
; On Adjoining Lots
To Nearest Edge of Absorption Field on Lot ,/,~1~ ; On Adjoining Lots
To Nearest Public Sewer Line _~_A,-- __ To Nearest Public sewer
Cleanout/Manhole
Water Sample Collected by _.
Water Sample Test Results
N
N.O_,~ ~'-- _ To Nearest Sewer Service Line on .Lot
~ '-~ ;Date ~///~/'/~¢'~
Comments
SEPTIC/HOLDING TANK DATA
Date Installed
Standpipes (Y/N)
Depression over Tank (Y/N)
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well __ ~ ~
To Property Line ~ ~
To Water Main/Service Line
Course ~
Comments
Size h,~O . NO. of Compartments '7'
Air-tight Caps (Y/N) __ )/ Foundation Cleanout (Y/N)
- ~'%~ Date Last Pumped _ ~/1~
Jk///A ;for
Temporary Holding Tank Permit (Y/N)
To Building Foundation
To Disposal Field
17
To Stream, Pond, Lake, or Major Drainage
Page 1 of 2
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Square Feet of Absorption Area
Depression over Field (Y/N)
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well
To Building Foundation
Lot
To Water Main/Service Line
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
Type of System Design
Length of Field ~ ~:~
Depth of Field }"~
Gravel Bed Thickness "7
Standpipes Present (Y/N)
Date of Last Adequacy Test
To Property Line ~ / _~
To Existing or Abandoned System on
; On Adjoining Lots ~' ~ ~)
To Cutbank (if present) 1"'4 ~ 'i~ ~
~ON-~
D. LIFT STATION NO~I~'
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verifie.,¢, or conformed to all MOA~nd HAA guidelines in effect on the date of this inspection.
Signed _~ 5~"¢''0~¢~ Date F//~ ~/~'./~'2~
MOA No.
/
Company
Receipt No.
Date of Payment /'~ - ~ (~'(-,¢
Amount: $ ~.~
Page 2 of 2
72-026 (11/84)
Engineer's Seal
CONSULTING ENGINEER
203W 15th AVE "C" SUITE 203
ANCHORAGE, ALASKA 99501
TELEPHONE: (907) 279-3916
SEPTIC
SYSTEM
ADEQUACY
TEST
LEGAL:
LOT 11, BLOCK 2, SILVERCREST
LOCATION:
7121 CANDACE CIRCLE
OWNER
ROBERT & AMY GRIMSEY
RESIDENCE:
SINGLE FAMILY, THREE BEDROOMS
WATER SYSTEM:
ON SITE WELL
SEPTIC SYSTEM:
FROM MUNICIPAL RECORDS:
TANK: GREER STEEL, TWO COMP. 1000 GAL.
ABSORPTION SYSTEM: TRENCH
ABSORPTION AREA: 504 SQ. FT.
SOIL RATING: 165
INSTALLATION DATE: AUGUST 1978
DATE OF PUMPING: APRIL 15, 1986 ISAACS PUMPING
DATE OF TEST:
APRIL 14, 1986
TEST PROCEDURE:
SYSTEM WAS INSPECTED AND MEASURED. TANK HAS
FIVE FEET OF COVER. WATER DEPTH 48 INCHES.
CLEAN OUT TO TRENCH IS FIVE FEET DEEP AND
DRY. TRENCH SUMP IS CRUSHED AND MUST BE
REPLACED AFTER BREAKUP. WATER SURFACE WAS SIX
FEET BELOW SURFACE. BOTTOM OF SUMP WAS NOT
ACCESSIBLE.
WATER WAS ADDED TO THE TREENCH AT A CONSTANT
RATE OF 5.75 GALLONS PERMINUTE WHILE THE
WATERLEVEL IN THE SUMP WAS MONITORED. A TOTAL
OF 300 GALLONS WERE ADDED. THE WATER LEVEL IN
THE SUM ROSE 21 INCHES. WATERLEVEL IN THE
TANK REMAINE.D CONSTANT. AFTER 30 MINUTES THE
WATERLEVEL IN THE SUMP WENT DOWN 15 INCHES.
TEST RESULT: THIS SYSTEM MEETS THE CODE REQUIREMENTS OF
THE MUNICIPALITY OF ANCHORAGE.
The operational life of all septic systems depends on the local
soil conditions, groundwater levels that may fluctuate during the
year, and the water usage of the family being served by the
system. These conditions are outside the control of the evaluator
of this septic system. We can therefore not give any estimate of
how long the system will continue to meet the operational requi-
rements of the Municipality and State.
CONSULTING ENGINEER
'Z03 W. 15th AVE "C" SUITE 203
ANCHORAGE, ALASKA 99501
TELEPHONE: (907) 279-3916
RESIDENTIAL WELL INSPECTION
LEGAL:
LOT 11, BLOCK 2, SILVERCREST
LOCATION:
7121 CANDACE
OWNER:
ROBERT, AMY GRIMSEY
TYPE OF WELL:
SINGLE FAMILY
WELL LOG AVAILABLE:
YES
INSTALLATION REQUIREMENTS MET: YES
WELL YIELD FROM WELL LOG:
.5 GPM
WELL YIELD FROM TEST:
.44 GPM
PUMP YIELD:
5.75 GPM
DATE OF INSPECTION:
APRIL 14, 1986
TEST PROCEDURE: WELL WAS PUMPED AT A CONSTANT RATE OF 5.75
GALLONS PER MINUTE WHILE THE DRAWDOWN WAS
MONITORED WITH AN ACOUSTIC PROBE. THE WELL
WAS PUMPED FOR 55 MINUTES AY' WHICH TIME THE WELL WENT DRY. THE
RECHARGE RATE WAS MONITORED FOR 25 MINUTES. THE RECHARGE RATE WAS
CONSTANT AT 3.5 MINUTES PER FOOT.
TEST FOR COLIFORMS: WATER WAS TESTED FOR COLIFORM BACTERIA ON
APRIL 15, 1986. TEST WAS NEGATIVE.
TEST RESULT:
THIS WELL ME]ETS THE REQUIREMENTS OF THE
MUNICIPALITY OF ANCHORAGE.
The Municipal requirement for well flow is
150 gallons of water per bedroom per 24
hours.This well surpasses this requirement.
The assessment of the condition of this well
applies only to the conditions as of this
date. The flow rate of the well may change
due to subsurface conditions that may not be
observed from the surface, and changes in
land use and other factors that may impact
the conditions of the aquifer feeding the
well.
APPLI( NT FILLS OUT UPPER HA[ ONLY
Buyer
Address Zip Code
Lending Institution Phone
Address Zip Code
Street Locah~ ~. Lb.y~.~,tfp.(~'C (~t}~('~
Type of Resi~nce
~Single Family
~ Multiplo Family ~o. of Bodroo~ L.
~ Othor
Water S6pply I'll FD U-~ ~ ,'~
~,lndividual A~ACH WELL LOG. A w~l log i~required for ail wells drilled since June 1975.
' ~ Community For wells drilled prior to that date, give well depth (attach log if available).
~ Public Utility
Sewer Disposal
~ Public Utility When Connected 1o Public Utility:
~ Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED.
Time Time Time Time
Date Date Date Date
Inspirer ,nsp~lor Inspirer
FieldNoles: ~ ~ DEPT, OF HEALTFI &
ENVIRONMENTAL PROTECTION
~' , ~ ,
~h:C, ' ' '"" "~' ' ' ~ ......
· RECEIVED
O'
(~ APPROVED BEDROOMS *CONDITIONS OF APPROVAL
( ) DISAPPROVED
( ) CONDITIONAL APPROVAL'
Soils Rating Date ~wer Installed ,,~
Q) ',' '~,') ~,~q~ v:, ,,-~ell To Absorption Area~ ~' ~]~ 0 ~ Well Log Received
72.023 (3182)
Lot L_, ~3ioc. k A, Szlv(.e:cro:-~L
be grant:od unt.:[.l, the .{o.J.J. owin,.] "'~'"~ _
~ ~f:i.].].O(] wJ. hh :Lm'lj)ervJ.ons 'hype soi.]. SO khat it. slopes away
ot 'u.~(..~ f.'[un' .[ci[)aJ..i. ty <:)f Anchouage. codes_ aud mu~t [)e 0neasod
in (i(~nduit ~
this
i _u. x- ~ v:ith ,'~ '~:'eCOi[)t sni)]~%ittod tO this
· ; .... u~: septic tank
neods to be ~;td)htittted to bhJ.:3 oJ:i:lCO ~o[' og'[; review,
call tJlJ. s oJlJiioe at 2(j4-,1-/20.
Sincerely,
l',rl(
ALABKA e dlROFIITleFITAL COFITIgOL IFIC.
~qin¢¢rinq $ ~nuiro,mcnlol $1odics
MAY 3 1983
ANTOINETTE GRAHAM
6945 CANDACE DRIVE
ANCHORAGE AK 99507
SELLER - ANTOINETTE GRAHAM
SUBDIVISION-SILVERCREST BLOCK-2
BUYER-ROBERT & AMY GRIMSEY
LOT-il
ADEQUACY TEST FOR SEWER SYSTEM
THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 504 SQFT.
THE SYSTEM IS CAPABLE OF ACCEPTING 450 GALLONS OF WATER PER DAY.
THE SURGE CAPACITY OF THE SYSTEM IS 280 GALLONS.
BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A
3 BEDROOM HOME.
FLOW TEST ON WELL ,~
THE WELL FLOW RATE WAS .5 GPM FOR/.8 HOURS.
THE DRAWDOWN OF THE WELL WAS 196 .
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK VOLUME OF
THIS 3 BEDROOM HOUSE.
1250 I8 ADEQUATE FOR
~200 LJJcsl 33rd Auenu¢, SuJl¢ J~ · Anchoraq¢. AJc~sko 99503 · [907) 276d361
ALASKA E dlROIqmEIqTAL CO[ITROL SEkuICES, IIqC.
May 5, 1983
Antoinette Graham
6945 Candace Drive
Anchorage, Alaska
99507
Dear Mrs. Graham:
On May 4, 1983 a well flow test was accomplished with a adequacy test at
Silvercrest Subdivision Lot 11 Block 2.
The well flow test started at 9:32 with static water level at 93' and
was run until 10:25. This was a total of 53 minutes at which time the
well stopped pumping. In this time the static level of water in the
casing had dropped from 93 feet to 289 feet which is the shut off point
for the pump. There was a total of 279 gallons of water used in this
time.
Static water level rise was recorded, the recovery rate indicates that
the well recovered at 32 gallons per hour the first hour and decrease
with time. It is estimated that if would take 10 hours for the well to
recover back to its original level.
A conservative estimate is that this well could produce 700 gallons per
day. However sustain water use as lawn watering, or several faucets
being used at the same time could draw the well do~ sooner that 50
minutes.
Normal water usage for a 3 bedroom house is 450 gallons per day with a
peak useage of 625 gallons per day. These figures are just below the
700 gallon per day we have estimated to be the output of the well. Note
this well is marginal to satisfactory. However, with normal water
useage and not overloading the system the well should be sufficient for
a 3 bedroom house.
Sincerely,
Civil Engineer
1200 LUCsl 33rr~ 5ui1¢ B · AD¢l~oroq¢, AI,sI<~ 99503 · {907) 276-1361
:., .: ~ ' " ~ ' ' w ....
,;? ~.) ~<~ , [ M,l(l:vd:P,f f'~[. ,l::.\, ii,L:: I},'~.IIi[)bJ~i:p.,ITt~I. II,OI'L--C,,TiON DEPT O;: }!EALTH &
:~.~ ' .P.~'",;4.X~;"' 'i'oi e pi mi~e 2fi4 4720 i J,.. L, 'l
~ sC A )~l(t';~
I
~- i ' 1 Om~ F-~ Four F ~ ()th(z:
MLJl. TIPLE{
I::AMi LY
[~. Three ['.J Six
SUPPLY
(~ INDIVIDUAl_ ' A J'q AC!! WELl. ~ '- -' Io: iequiled for all ,.veils driih d
FT. COMMLINI i"Y sin<c June '1975. Fo~ ,,,/ells drilled prior to that date, fiive
[~1 PUBLIC LFTILITY del:ih ~:dtach Ion if avai :t L)
St~WAGH DISPOSAl. SYSTEM
()F RI:iSIDEN(JE NUI~lt~ER OF
LI*JI FIPLEFAMILY [~'~ 'lWO [ i FOUR [] SIX
t¥~[q M FI- NIjMt~ER
SUPPLY
Ik!DIVIDUAL DEPTH OF WELL
(;OF.,iMUN ITY
DATE Dltl
/i~L IC UTII..ITY
.:Mi.'[)i'.II)UAI.,/ON-SITE ~)/~TE I'N~ IAi t.ED
tJ-I ILITY
I! Tank is homemade ~ii:~ii~-r,'<
, ,[ f;OliP~ IOF, J AFl E/~ k4ATERIAL
......