Loading...
HomeMy WebLinkAboutSTUCKAGAIN MANOR BLK 1 LT 8ARick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 August 12, 1996 Louis E Mayer Lillian M Mayer 3300 Providence Drive #301 Anchorage, Alaska 99508 Subject: Lot 8 Block 1 Stuckagain Manor Subdivision Permit #SW950207, PID #041-023-23 The subject permit, issued August 10, 1995 by this office for a single family well and/or on-site wastewater system, has expired as of August 10, 1996. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. S~ely, Pr~ram Manager On-mite Services enc: Copy of Permit cc: James Mark Wright, P.E. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 82S "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519 6650 PAGE 1 OF 1 ON SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW950207 DESIGN ENGINEER:JAMES MARK WRIGHT, P.'E. OWNER NAME:MAYER LOUIS E & LILLIAM M OWNER ADDRESS:2734 HAUITUR WAY ANCHORAGE, ALASKA 99504 DATE ISSUED: 8/10/95 EXPIRATION DATE: 8/10/96 PARCEL ID:04102323 LEGAL DESCRIPTION: STUCKAGAIN MANOR BLK 1 LT 8 LOT SIZE: 55540 (SQ. FT.) NUMBER OF BEDROOMS: 5 THIS PERMIT: THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: ISSUED BY:~J ,~ ~~--~ July 24, 1995 Department of Health and Human Services Anchorage Alaska James Mark Wright P.E. 2900 West 33rd Ave. Anchorage Alaska 99517 (907) 243-4361 RE: Lot 8A, Block 1, STUCKAGAIN MANOR SUB'D. Dear DHHS, This is a request for an on-site wastewater disposal system and an on-site well permit. No onsite system presently exists (new residence). The existing systems on surrounding lots appear to be performing adequately. The percolation rate was found to be 1.4 min/inch. No impacts to the surrounding properties are foreseen. The owner intends to install both the primary and secondary systems at the same time. Valves isolating both systems will be installed. The topography of the area is a westerly slope of about 2%. The lot footprint is about 221' by 264' for an area of 66,870 square feet. Sincerely, /~/James Mark Wright P.E. MUNICIPALITY OF ANCHORAC~E ENVIRONMENTAL SERVICES DIVISION ,.~UL 2 7 1995 RECEIVED Permit No. Page f of ~'~ Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 eAnchorage, Alaska 99519-6650 eTelephone: 345 4744 On-Site ~cj:stewater Disposal System and/or Well Inspection Report Legal Description: [-~,'ff'-~'- ~:~- ] PID No. FROM SEPTIC TANK CLEAN OU~~ PLAN VIEW ~ FILTER FABRIC ~- ~" PERFORATE3 PIPE ~65 LIN. FT. ~" 3' S = 0.0%, MIN. COVER 8.5j ELEVATION 5~ ¥'CLEAN OUT MONITORING TUBES FROM SEPTIC TAN K ~h~ FILTER FABRIC z[" PERFORATED -DRAIN ROCK SECTION PIPE STUCKAGAIN MANOR, LOT 8, BLK. 1 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION; I 2, 3- 4 5 6 7 Jr? A-N o~ . 8 9, 10- 11 12- 13- 14 15 16 17 18 19- 20- Township. Range. Section: SLOPE SITE PLAN Reading Date Time Time Water Drop I~/~-~ ~-/~.?/~- /~;~z i'z." Jl ~ 3~ ~*~ PERCOLATION RATE I, ~ r I~nJr~uJe~/',oc~lI Pe~c HOLE DIAMETER :OMMENTS PERFORMED BY: f/~ ,Z~-/~ ~' g'~)/"{/'~" -/~ ~-- i CERTIFY THAT THiS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE· DATE: ,,~/2--- 7 /~,,~'--- PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502.0650 SOILS LOG -- PERCOLATION TEST · E~AI. CSSCm.TiON= L.-o-'r p~,~., I 2 3 4 5 6 7- 8- 9- 10- 11 12 13 14 15 16 17 18 20- DATE FERFORMED Township, Range, Section: SLOPE ENCOUNTERED? SITE PLAN S L IF YES, AT WHAT O DEPTH? p E Oep~J~ to Water ~e~ ~,.',, ~/ · Gross Net Deom to Net Reading Date Time Time Water Drol~ PERCOLATION RATE TEST RUN BETWEEN ~ FT AND ~ FT ,~OMMENTS PERFORMED BY: /~ -~ ,/~ '~ /~"~ / ['~ /"/- ~'-- J ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: , ~-'/~" ~/'~ (~'--