(907) 343-7904
Pump Installati®n L®
Well Drilling Permit Number: SW OSP Date of Issue:
Parcel Identification Number: 051-511-28-000
Legal Description Property Owner Name & Address:
Suetawn Est L 7 Kourosh Partow
19507 Richner Rd
Chugiak, AK 99567
I Pump Installation Date: 12/1120202
I Pump Intake Depth Below Top of Well Casing: 35
I Pump Manufacturer's Name: Goulds
Pump Model: 7HS05412CL
I Pump Size 1i2 hp
I Pitless Adapter Burial Depth: 9 feet
I Pitless Adapter Manufacturer's Name: Campbell
Pitless Adapter Installer: unknown
Well Disinfected Upon Completion? ✓7 Yes ❑ No
Method of Disinfection: Sterilene
Comments:
Pump Installer Name: Wheaton Water well, Inc.
1190 N. Wasilla-Fish hook Road
Wasilla, AK 99654
feet
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
Development Services Department
Building Safety Division
e
On -Site Water & Wastewater Program
G
4700 Elmore Road
U
P.O. Box 196650
x z
Mark Begich
e, AK 99507
Anchorage,
g
s E T Y
Mayor
www.muni.org/onsite
(907) 343-7904
Pump Installati®n L®
Well Drilling Permit Number: SW OSP Date of Issue:
Parcel Identification Number: 051-511-28-000
Legal Description Property Owner Name & Address:
Suetawn Est L 7 Kourosh Partow
19507 Richner Rd
Chugiak, AK 99567
I Pump Installation Date: 12/1120202
I Pump Intake Depth Below Top of Well Casing: 35
I Pump Manufacturer's Name: Goulds
Pump Model: 7HS05412CL
I Pump Size 1i2 hp
I Pitless Adapter Burial Depth: 9 feet
I Pitless Adapter Manufacturer's Name: Campbell
Pitless Adapter Installer: unknown
Well Disinfected Upon Completion? ✓7 Yes ❑ No
Method of Disinfection: Sterilene
Comments:
Pump Installer Name: Wheaton Water well, Inc.
1190 N. Wasilla-Fish hook Road
Wasilla, AK 99654
feet
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
tnev uoiuu-w)
Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3
ON-SITE
WASTEWATER INSPECTION REPORT
Permit Number: OSP201318
PID Number: 051-511-28
Dwelling: ■❑ Single Family (SF)
❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: X New ❑ Upgrade
Name
Troy Davis Homes, Inc.
ABSORPTION FIELD
❑ Deep Trench X Wide Trench ❑ Bed ❑ Mound
Site Address
1689 Goose Bay Road, Suite
400 Wasilla, AK 99654
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
310-2501
4
1.0 GPD/SF
6.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
5.5 Ft.
Gravel depth beneath pipe
0.5 Ft.
Subdivision
Block Lot
Sue Tawn Estate
7
Fill added above original grade
1.2/0.7 Ft.
Gravel length
62/60 Ft.
Township Range Section
Gravel width
5.0 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
610 Ft2
2
5.5 Ft.
Well
>100'
>1 00'
N/A
N/A
>25
TANK X Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Greer
Capacity
1,250 Gal.
Surface Water
>1
>1 00'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
NA
Plastic
2
Foundation
>10'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Gal.
Remarks
Alarm location
Electrical installed by
PIPE MATERIAL House to tank F'628 drainfield Tank to
D3034
Installer
Alex Enterprises
Drainfield D3034 Co/MTD3034
Inspector J. Mlllette
BENCH MARK (Assumed elevation) 100 ft
Inspection 15' 10/24/20
11/12/20
Location and description
31d 11/16/26
2�a
4'h
Garage Slab.
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
+®®®OF
Conditional Approval:
Date
.��P
•
;, s
®�
�p 49th =�
y�
10 .. ...................... 0 ..................... . s
MICHAEL E. ANDERSON .'fie
Septic System
® C
®% % NO. CE -4381 : �Ar
A roved
pp
Date 2
-0"q.%.. 1/5/21 ,,.••''��`'®
A�F� ••............•
.
Note: this approXedoes
not include well permit requirements.
tnev uoiuu-w)
9:C)i:C-)
-AO--1O--�O-�O�
�
Ocnrn
cn
�H)s
D W cn
Z� ir
�zC�
�'��Z-1
4A
.AW
W
N
N
-i
-�
O
C=
n
1 O /
O
co
co
-P
-A
co
CO
J !
M*
/
ONS X _
wo:01-9)p
jl
oo-,Wcow
co
co
N
N
co
W
W
w
w
w
N�
W
—
X1
00
p
p
O
'J
N
O
p
�!
C.0
N
O
-P
---j
co
O
W
cn
O
O
N
m0)
P
P
W
.t-wwcocn711
NNW
O
O O
U 7
D
1'
C7 �I
1
—I m EZE� m -n N o r /
S<—i=MOOO M
n m
vm0D0000o
--jTF 0D
=c�pcnzwz
O rn m r- D rn 0
m z, -I ---1 0
-I G7 m O m
z
C n Z
W r, O
rn D C
Z �
MM
W o
�
Ocnrn
cn
�H)s
D W cn
Z� ir
�zC�
�'��Z-1
a
0Z
Z
N O
1
?`ZTO>
mm�mm
-� 1
i =i�
DL mzm
-0
�cn=x
n
1 O /
.0 m�< -1
Zmcn_m
-IS0�C>
m
�5
M* 0
J !
M*
/
ONS X _
jl
U)
C
m
z
m
111
cn
m�
111
SUE TAWN ESTATE, LOT 7
PERMIT # OSP201318 PID # 051-511-28
90.2
89.7
90.2
89.7
QNGINEQRINC
0� NORTH TRENCH 1-0
96.4 FINISH GRADE 95.7 ORIGINAL GRADE
DRAINFIELD ROCK 90.2
MOA APPROVED FILTER SAND 89.7
"— 87.7 60'
NO GROUNDWATER 8/11/20
82.7
C,'r)HTH TPf=KIrW
87.7
0
n 1 96.9 FINISH GRADE 95.7 ORIGINAL GRADE
DRAINFIELD ROCK 90.2
MOA APPROVED FILTER SAND 89.7
87.7 87.7
62'
PROFILE AS -BUILT
(NO SCALE)
�t
Municipality of Anchorage
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Proaram
'I
Ur. p;retment
x x x x VARIANCE/WAIVER REVIEW x x x x
Waiver#: OSV211001 COSA#: Permit#:OSP201318
PID#: 051-511-28
Legal Description: SUETAWN ESTATE LT 7
Engineer: Forge engineering
Your request for a waiver of the required 6 feet horizontal separation from absorption field to the
absorption field has been approved. The approved separation distance is 5.5 feet.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
■ .... ■ ■ ............................. ■ ■'........ ■ ■ ............................. ■ t
Waiver is Granted: X Waiver is not Granted:
Date: 1A, (A Approved by:
Name of Revie r
**** VARIAN C E/WAIVER REVIEW ****
j
33.0'
I
L
D
N
K
Z
M
I
Lot 6
I
Lot 8
I
NOTE:
1) PLAT NOTE: ALL LOTS EXTEND TO CREEK
LEGEND:
(R) RECORD FROM PLAT No. 64-9
Lot 5
PLOT PLAN AS BUILT X SCALE 1" — 30__ GRID _ NW 1060__ Project No.
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, inc. (907) 522-6476 Phone oopppp40
(907) 522-4625 Fax oF A p�O
Professional Land Surveyors kenOlangsurvey.com o !� 9 0
ionathanOlanasurvev.com O� .• . .�.�n
I hereby certify that I have surveyed the following described property:
LOT 7, SUETAWN ESTATE (PLAT No. 64-9)
Anchorage Recording District, Alaska, and that the improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on said property except as Indicated hereon.
Dated this the �P _ Day of ____- S -LLL at Anchorage, Alaska
It is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat.
49THW *i
m ' KENkNETH. LANG o
3�2a2o •' �*�
�D�cFo ..CCS 5202.•
4OnRaFfSSIONA� � 00
AECC963
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP201318
Work Type: WellSeptic Initial
Tax Code Number: 05151128000
Site Legal Address: SUETAWN ESTATE LT 7 G:1060
Site Mailing Address: 18725 JASMINE RD, Chugiak
Owner: KEHOE-PARTOW DEANNA
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
sr
S
cn
do'
t r-
n
v r, V
Department
Lot Size in Sq Ft
Total Bedrooms:
8/26/2020
8/26/2021
52272
Q Disposal Field Q Septic Tank Holding Tank Privy Q Private Well Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By:
Issued By:
Date:
Date: S 6 Zf>
4
8/26/20
n
MUNICIPALITY E ANCHORAGE
Community Development Department `' Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-511-28
Property owner(s) Troy Davis Homes, Inc. Day phone 310-2501
Mailing address 1689 Goose Bay Road, Suite 400 Wasilla, AK 99654
Site address 18725 Jasmine Road Chugiak, AK
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) Sue Tawn Estate, Lot 7
Lot Size 52,272 Sq. Ft. Number of Bedrooms Four (4)
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial ❑X
Single Family (SF) ❑X
(w/wo AD U)
Septic Tank
❑X
Upgrade ❑
Duplex (D) ❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings El
Privy
❑
(SF and/or D)
Private Well
❑X
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: -A01.s C©U10 Waiver Fees:
Date of Payment: IS ZO Z O Date of Payment:
Receipt Number: (56%%3 © Receipt Number:
Permit No. 05 192-01-3)5 Waiver No.
Permit App_:;- : ._.,:c
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
August 26, 2020
M.O.A. Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Subject: Sue Tawn Estates, Lot 7 – 18725 Jasmine Road
Septic System Design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 4-bedroom home on the property. We are submitting
this permit application for the construction of a septic system. A well is currently in place on the
lot which will serve the new home. The attached site plan identifies the location of the home and
the existing well, existing and proposed septic location and alternate site. No conflicts exist
between this proposed system and any other well or septic system on this lot or adjacent lots.
The ground surface on the lot slopes to the north at grades approximating 10%. There are no slopes
greater than 25% within 50 feet downslope of either the primary or alternate site. Ground contours
are shown on the site plan indicating the grade and direction of flow. Stormwater drainage will not
impact this septic system. The new trench will be constructed parallel to the slope as much as
possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water and more than 5’ from the septic tank.
Please refer to the attached test hole logs and plan and profile sheets for the septic design. If this
design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, PE
8/26/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201318, Deb Wockenfuss, 08/26/20
x x x x
2-60' LONG x 5' WIDE x .5'
EFFECTIVE DEPTH
ABSORPTION TRENCHES.
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH
WELLS OR SEPTIC SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FD - FLOW DIVERTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGENDJASMINE ROADSUE TAWN ESTATE, LOT 7
1"=50'
MT
8/26/20
10050 0
FEET
LITTLE PETERS CREEK
4-BDRM HOME
EXISTING WELL
ALTERNATE SITE
ABANDON EXISTING
ABSORPTION TRENCH.MT
CO
COCO
CO
MH
FCO
2CO
SV
TH
660
655
SV
1,250 GALLON SEPTIC
TANK w/20" MANWAY.
DECOMMISSION EXISTING
SEPTIC TANK PER U.P.C.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201318, Deb Wockenfuss, 08/26/20
SUE TAWN ESTATE, LOT 7
DESIGN FACTORS: SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5' WIDE TRENCH SYSTEM
1,250-GALLON SEPTIC TANK
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 4.5' BELOW GRADE
FLOW LINE ELEVATION: 4.0' BELOW GRADE
TOP OF TRENCH: 0.5' ABOVE GRADE
600 GPD / 1.0 GPD/SF /5' WIDE * 1.0 (RED. FACTOR) = 120 LF TRENCH REQUIRED (120 LF SPECIFIED)
8/14/20
4" PERFORATED PVC
(HOLES DOWN)
DRAINFIELD ROCK
5'
6" ORIGINAL GROUND
6"
MOA APPROVED SAND2'-0"
3'-6"
6"
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201318, Deb Wockenfuss, 08/26/20
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 1
SLOPE
SLOPE
SITE PLAN
DATE READING GROSS TIME
(minutes)
NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
SUE TAWN ESTATES, LOT 7
8/4/20
J. MILLETTE
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH? -
<1 6
2 3
051-511-28
TROY DAVIS HOMES, INC.
9:25
---
1
2
3
4
5
6
6/0
9:26
9:27
9:29
9:31
12:37
1' OB
Professional Engineers Stamp:
8/14/20
<1
NO
NONE
8/11/20
GP
POORLY GRADED GRAVEL
w/LARGE COBBLES
6
6/0<1 6
6/0<1 6
6/0<1 6
6/0<1 6
6/0<1 6
Percolation test measurements completed to 1/16" increments.
Sand liner required.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201318, Deb Wockenfuss, 08/26/20
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
~ ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LOCATION NO. OF BEDROOMS
Well ¢~ ~ l Absorption area
~ Liq.~gallons IF HOME'DE: Inside length Width Liquid depth
, ~ Well Dwelling PERMIT NO.
~Oz DISTANCE TO:
0 ~ ~ Manufacturer Material Liquid capacity in gallons
~ Ne.DISTANCE TO:of lines ~'~Le%g~ o~ ~ 'ne ~' Total length *~g Distance b~ lines
~¢ Trenc~ wid~, inches Totten area
~ ~ ~ Top of til~o finish grade~
Length Widtfi Depth PERMIT NO.
~ ~ Type of crib Crib diameter Crib depth Total effective absorption area
~ Well Building foundation Nearest lot line
~ DISTANCE TO:
a Class Depth Driller Distance to lot line PERMIT NO.
~ DISTANCE TO: ~uilding foundation Sewer line Septic tank Absorption area(s)
OTHER
(Rev. 3/78)
HERLTH 8ND ENVIRONMENTBL~ROTECTION
~,25 ~ STREET., RNCHCR~GE RK. 99501
~['l--S Z TE SEWER pERr'I Z T
RPFLICRNT BILL RLTER PO BOX 796 E.R. 99577 694-9~b
L,]GRL L7 SUETRWN ESTRTES LOT SIZE 999999 SQLIR~FEET
T~PE OF SOIL RBSORPTION SYSTEM I_.'~' TRENCH
MR~IMUM NUMBER OF BEDROOMS = 4 SOIL RRTING
THE REBUIRED SIZE CIF THE 50IL 8BSORPTION ~LTEM~' ~ IS: ~,
DeEP'TH= ti LE[4GTH= 25 ~]RR%¢EL E>EPTH= 7
THE LENGTH DIMENSION IS THE LENGTH <IN FEET> OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE
GROUND RND THE BOTTOM OF THE EXCRVRTION <IN FEET>.
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE
RND THE BOTTOM OF THE EXCRVRTION (IN FEET>.
REC4.1J 'r RED SEPT I C TRI'-.II-.-: $ I ZE= ::L250 GRLLOI'-IS
PERMIT RPPLICRNT HRS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE
INSTRLLRTION INSPECTIONS OF RNY WELLS RDJRCENT TO THIS PROPERTY RND THE
NUMBER OF RESIDENCES THRT THE WELL WILL SERVE,
TWO ( ~- ) I NSPEF:T I C~-~S RRE REC41J I RED
BRCKFILLING OF RNY .~t_TEM WITHOUT FINRL INSPECTION RND RPPROVRL BY THIS
DEPRRTMENT WILL BE SUB..TECT TO PROSECUTION.
MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS
±00 FEET FOR R PRIVRTE WELL OR 150 TO 200 FEET FROM R PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTRNCE FROM R PRIVRTE WELL TO R PRIVRTE SEWER LINE IS 25 FEET RND
TO R COMMUNITY SEWER LINE IS 75 FEET·
OTHER REQUIREMENTS MRY RPPLY. SPECIFICRTIONS RND CONSTRUCTION DIRGRRMS ~RE
RVRILRBLE TO INSURE PROPER INSTRLL8TION.
F"ERr.1 I T E,~.'F" I RES DECEMBER --~--i.- :1_982
I CERTIFY THRT
±: I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET
FORTH BY THE MUNICIPRLITY OF RNCHORRGE.
2: I WILL INSTRLL THE SYSTEM IN RC:CORDRNCE WITH THE CODES.
~: I UNDERSTRND THRT THE ON-SITE SEWER SYSTEM MRY REBUIRE ENLRRGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THRN 4 BEDROOMS.
' RPPLICRNT BI~n RLTER ~~,
O & E EN~NEERING & DEVELOCMENT CO.
Box 90, Davis St., Eagle River, Alaska 99577
694-2774 or 688-2280
Russell Oyster
694-2774
Performed for:
Name:
Mailing Address:
Legal Description:
Depth (feel)
Earl Ellis
SOIL LOG 688-2280
,/~ ~-~- ,~ ~'~-~-/'~ __ . Tel. No. ~'T ~/~
Soil Characteristics
0
2__
3__
4__
6__
7__
8__
9__
PLOT PLAN
12__
13__
14__
15
16__
Ground Water Encountered: Yes
Proposed Installation: Seepage Pit
Comments:
,,.]
No ~ If yes, what depth
Drain Field
PERC. TEST
Performed by:
0 &' E EL_~INEERING ~' DEVELO~M4ENT CO.
Russell Oyster
694-2774
Civil Engineering
Soils 8- Foundations
Box 90, Davi~ St., Eagle River, Alaska 99577
694 2774 or 333 5240
Earl Ellis
333-5240
Surveying
Land Development
PERMIT NO.
RPPLICRNT BILL RLTER BOX ?96 E.R. 99577
LOCRTION
LEGRL L? SUE TRWN LOT SIZE
694-9t~0
999999 SQURRE FEET
MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS
±00 FEET FOR R PRIVRTE WELL OR 150 TO 200 FEET FROM R PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DIS]RNCE FROM R PRIVRTE WELL TO R PRIVRTE SEWER LINE IS 25 FEET RND
TO R COMMUNITY SEWER LINE IS 75 FEET.
WELL LOGS RRE REQUIRED RND MUST BE RETURNED TO THE DEPRRTMENT WITHIN ~0 DRYS
OF THE WELL COMPLETION.
OTHER REQUIREMENTS MRY RPPLY. SPECIFICRTIONS RND CONSTRUCTION DIRGRBMS RRE
RVRILRBLE TO INSURE PROPER INSTRLLRTION.
PER~'~ I T E,~'~ F' I RES DECEMBER
I CERTIFY THRT
t: I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET
FORTH BV THE MUNICIPRLITY OF RNCHORRGE.
2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES.
RFFLtCRNT BILL RLTER C/ / ~ ~
..... ....
V4. 0
DOC Co. dba
P.O, BOX 272 CHUGIAK ALASKA 99567 o TELEPHONE688.2759
OWNER OF LAND _,/,~/ff&
LEGAL DESCRI~ION
DATE- Started _ ~'//
PERMIT NUMBER
DEPTH OF WELL ~
STATIC LEVEL OF WATER FT. .~)'.2 __
DRAW DOWN FT.
GALS. PER HR ~'~ ,,.,d ~j
KIND OF CASING (..[. -h~ , '
KIND OF FORMATION:
From /~ Ft. to_ '~'~' Ft. __ ~-: c~,. ,*. o d,4 c ~,~:- *' ~-' From
From~Ft. to Ft._ 'f<a ff ~ From.~
From ': Ft to ~',,? Ft. /72~4~;~fl, , -' ~ - -,,
~ . _ , . ~,~,~. ¢~A From
From ~J
From~ Ft. to ~Ft.
From~Ft. to_ Ft. ~./ ,'~. ~ /~ _
/
From~Ft. to~_Ft~
From Ft. to _Ft._
From Ft. to __Ft.
From Ft. to Ft
From Ft. to_ Ft
From Ft. to Ft
From Ft. to Ft.
From Ft. to _Ft.
From_ Ft. to Ft.
From
From
From
From
From
From __
From __
Frmn __
From __
Ft. to_
Ft. ta__
Ft. to___
Ft. to
Ft. to
Ft. to.__
Ft. to
__ Ft. to~
Ft. to
Ft. to
Ft. to
Ft. to
Ft. to
_Ft. t~
Ft. to
__Ft. to
Et. to_
Ft
Ft.
_Ft.
Ft
_Ft.
_Ft.
Ft.
_ Ft.
Ft
_Ft.
Ft.
Ft_
MISCL. INFORMATION:
DRILLER'S NAME
APPLI(~IT FILLS OUT UPPER HAI%~::ONLY
Property Owfler , ~.?'~j Z ~ ~ ~ Z ~ ~ , ~ Phone
Realty Co. ~' A~n~ ~ / ' Phone
Address Zip Code
Legal Desoript[on /
Type of Resi~nce
Single Family
~Uultiple Family No. of Bedroo~
~ Olher
Water Supply
~ I.dividual ~ ~ ~ [~C~' A~ACH WELL LOG. A w~l log is required for all wells drilled since June 1975.
~ Community ~ ~ ~ For wells drilled prior to that date, give well depth (attach log if available).
~ Public Utility
Sewer Oisposal
~ Public Utility
~ Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSlNG CAN BE INITIATED.
Time Time Time Time
Date Date Date Date
Inspector Inspector Inspector Inspector ¢
0 C'i' 2 0 1982
,~ __ ~!,~ w~, to Tank Sept,c T,~k Si~e I ~
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Parcel ID 051 -511-28
Certificate of On -Site Systems Approval
OSC251029
Expiration Date: 1/21/2026
Legal description SUETAWN ESTATE LT 7
Site address 18725 JASMINE RD
Current property owner(s) BECERRIL COURTNEY L&
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for
Comments or conditions:
No comments
bedrooms, with the following stipulations:
By:/�, Original Certificate Date: 2/4/2025
This Ce ificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s)is/are in substantial compliance with municipal code. The Municipality of Anchorage,
Development Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
MUNICIPALITY OF ANCHORAGE
D4;��
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 051
Complete legal description SUETAWN ESTATE LOT 7
Location (site address) 18725 JASMINE ROAD EAGLE RIVER, ALASKA 99577
Current property owner(s) COURTNEY & RICHARD BECERRIL Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass
Age 4 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ® Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ Waiver Fee $
Date of Payment Z Z 02 Date of Payment
COSA # 05('_2_5/009 Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: SUETAWN ESTATE LOT 7 Parcel ID: 051-511-28
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled August 1982 Total depth 49’ 10” ft
Cased to 50 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 36 in.
Date of flow test for COSA 1/24/25
Static water level at beginning of test 23 ft.
Well production at time of test 3+ gpm
Water storage tank volume *300+ gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 0.921 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 1/21/25
Comments *300+ gallon storage tank in crawlspace.
B. TANK DATA
Measured operating fluid level in septic tank 57”
Date of pumping 1/22/25
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 11/16/20
ALL standpipes present per record drawing
Total measured depth from existing grade 8.8 ft (max)
Measured depth to pipe invert from grade 5.3 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced 2000 gallons 1/23/2025 date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 1/24/25
Results Pass
Fluid depth prior to test 0 in
Water added 600 gal
New fluid depth 1 in
Elapsed time 30 min
Final fluid depth 0 in
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 6 in (MOA 0.5’ ED)
Effective depth used 0 in (Final Fluid Depth)
Effective depth (ED) remaining 6 in
Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots,
visual observations, MOA records & appears approximate.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 2/3/2025
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
02/03/25
MUNICIPALITY OF ANCHORAGE
Development Services Department �;W' �.. Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
051-511-28 p q-
1.
Parcel I.D. Ex iration Date:
GENERAL INFORMATION
Complete legal description Sue Tawn Estates, Lot 7
Location (site address) 18725 Jasmine Road
Chugiak, AK
Current property owner(s) Kourosh Partow Day phone (907) 310-2501
Mailing address
Real estate agent
19507 Richner Road Chugiak, AK 99567
2. TYPE OF DWELLING:
❑■ Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
Private Septic
Q
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 75
Date of Payment 02 f
Receipt Number nI q 2_1)
COSA # OSC211019
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this, application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Forge Engineering Phone (907) 522-7773
Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503
Engineer's Printed Name Michael E. Anderson, P.E. Date 1/15/21
z 831 IA-1Sb'M
BOriginal Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
.�®�� q� ®ago
...................
a' 49th
6. DSD SIGNATURE
+It. .0IT
3
C
0................................................_...
®d7�MhilCHAEL
System #1 Approved for
bedrooms E. ANDERSON 8
System #2 Approved for
% No. CE -4381 �•'
'
bedrooms e sT=.. ,.• �:
®®4a®®4
Disapproved
1/15/21
.•
PROFCSS\C 11W
®11'0aa®a®®'
Conditional approval for
bedrooms, with the following stipulations:
WH4nnu,
z 831 IA-1Sb'M
BOriginal Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Sue Tawn Estates, Lot 7
If more than 1 septic system on lot: COSA Checklist #
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled August 1982
Total depth 50 ft
Cased to 50 ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) '18 in.
Date of flow test for COSA 1/5/21
Parcel ID: 051-511-28
of Structure served by this system
Well production at time of test 2.5* gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test? ❑ Yes ❑ N
❑ Coliform bacteria is Negative
Nitrate 0.028 mg/L ❑ Nitrate less than MRL (ND)
Arsenic 0.31 ug/L ❑ Arsenic less than MRL (ND)
Collected by Wheaton Water Wells
Date of Sample 12/14/20
Static water level at beginning of test 23 ft.
Comments *Well testing completed by Wheaton Water Wells
B. TANK DATA
Age of tank(s) <1 years
Tank type/material Septic/Plastic
Measured operating fluid level in septic tank New
❑ Standpipes/foundation cleanout per record drawing
Date of pumping Tank placed 10/24/20.
D. ABSORPTION FIELD DATA 5' Wide Shallow Trenches
Which system tested (date installed) 11/16/20
IN ALL standpipes present per record drawing
Total measured depth from grade 7.2/6.7 ft (max)
Measured depth to pipe invert from grade 6.76.2 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments: Septic System is gravity flow.
Adequacy test date New Construction
Results [] Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
Absorption Trenches constructed 11/16/20.
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
❑✓
Yes
Community Sewer Manhole/Cleanout > 100'
Q Yes
if No
ft
Q Yes
if No ft
Neighboring Tank > 100' F/� Yes
if No
ft
Private Sewer/Septic Line > 25' 0 Yes
if No ft
Absorption Field on Lot > 100' F/� Yes
if No
ft
Holding Tank > 100' Fv� Yes
if No ft
Neighboring Absorption Fields > 100'
Yes
if No
Animal Containment > 50' R Yes
if No ft
0 Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' F/1 Yes
if No
ft
0 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' F✓ Yes if No ft Surface Water > 100' ®✓ Yes if No ft
Property Line > 5'
❑✓
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
[✓
Yes
if No
ft
Private Wells > 100' 0✓ Yes if No _
Water Main > 10'
✓V
Yes
if No
ft
Community Wells > 200' Q✓ Yes if No _
Water Service Line > 10'
M✓
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' Q✓ Yes if No ft If absorption field is under driveway comment below
Property Line > 10'
0
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
F.71
Yes
if No
ft
Private Wells > 100' U Yes if No
Water Service Line > 10'
0
Yes
if No
ft
Community Wells > 200' U Yes if No
Surface Water > 100'
0
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
��E�OF
49th
-
1 ........ .....14 ....... .92.,...........,..... i
o MICHAEL E. ANDERSON
No. CE -4381
1/21/20
ft
�I
ft
ft
<<
a=o
o_w
m
N 00'05'W 150.00'
0
ri
n
JASMINE ROAD
M
q
�o
t
0
q+
m m
w
««ten
t rmn C
m fl 0 0«
O a
I n
0, o
o s
0
`a `c'�o `o
a
m o:cc
�I mo
u ao o c o
I m
vq E«`m—°qm
s
omgo
++
C
m
� C
'n
n
° 02
waavo�x
9 O m m
O t
i
� 3
«
oaw°nOm
-da---ON n
«y+T'g.o
-I =�
I at
Lv�izo.Eco
no
«
o >
® q
e�LtEEm
+c
m
4 3 c M.
o " 00
N 00'05'W 150.00'
0
ri
n
JASMINE ROAD
M
q
�o
t
0
q+
m m
o m a
o En
««ten
t rmn C
m fl 0 0«
O a
I n
0, o
o s
0
`a `c'�o `o
I o
m o:cc
�I mo
u ao o c o
I m
vq E«`m—°qm
s
omgo
++
C
m
� C
'n
n
° 02
waavo�x
9 O m m
O t
i
� 3
«
oaw°nOm
-da---ON n
«y+T'g.o
-I =�
I at
Lv�izo.Eco
no
«
o >
® q
e�LtEEm
+c
m
4 3 c M.
o " 00