Loading...
HomeMy WebLinkAboutSUE TAWN ESTATE #2 BLK 3 LT 8Onsite File 119— Municipality 1 1Kev UDIULI-I0) r� rfi Municipality of Anchorage On-Site Water and Wastewater Section - (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT N®V Iit zo. Permit Number: OSP 191370 PID Number: 051-511-34 .I1 19 Dwelling: Al Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name Robert and Nan Sickler ABSORPTION FIELD ❑ De Trench El Wide Trench F-1 Bed El Mound Site Address 18610 Sue Tawn ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 PD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original de 7, Gravel depth beneath pipe Ft. Subdivision Block Lot Sue Tawn Estate #2 3 8 Fill added above original grade Ft. G el length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Dis ce between lines Ft. SEPARATION DISTANCES To Septic AbsorptionI Lift Station Holding I Serer Total absorption area Number of trenches Dist. between enches From Tank Field Tank Line Ft2 Ft: Well >100' NA NA NA NA TANK R Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Infiltrator Capacity 1530 Gal. Surface Water >1 QQ NA NA NA Material Number of compartments Lot Line > 10` I NA NA NA NA plastic 2 Foundation >10` NA NA NA LI TATION Manufacturer Capacity Remarks 2" insulation over top of tank Gal. Alarm location Elec ' stalled by PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Installer Territory North Constructors Drainfield NA CO/MT3034 Inspector Curtis Townsend, PE BENCH MARK (Assumed elevation) 100 ft .Ir 8/27/19 8/28/19 Inspectionda Location and description 2nd 31d 9121/19 4111 top of concrete porch by rear door ON-SITE WATER AND WASTEWATER SECTION APPROVAL Ear ktamp A Conditional Approval: Date 0�'��,••• � 01 iH��� ods0 do 'se . • • Curs L T • i� �� ��• Date 1 r /Y � Septic System l)FcifT� No. CE i lr��ms ����� °ROFESSi�hP�4 Approved Date Note: this approval does not include well permit requirements. 1Kev UDIULI-I0) r� rfi NEIGHBORING SEPTIC IS APPROXIMATELY J 10' FROM PROPERTY 1 1 +� LINE NEIGHBORING WELL IS— > 30' FROM �1AG EASNNA PROPERTY LINE \ 25 pRA� 237' THERE ARE NO STEEP SLOPES WITHIN 50' OF THE PROPOSED �y� 1 G SHED'tSUMP 1 I TANK. 100' 'dF 'QS c1pfiFr SHED JAW) ABANDONED WELL SCOPE OF WORK 1. REMOVED EXISTENG SEPTIC TANK. 2. PLACED NEW 1,530 GALLON PLASTIC SEPTIC TANK AND TIED INTO EXISTING ABSORPTION SYSTEM. THE TANK WAS PROVIDED WITH 20" 0 MANWAY RISER SERVING THE FIRST COMPARTMENT. 3. ALL CONSTRUCTION WAS IN ACCORDANCE WITH ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65- NEIGH80RING WELL IS > 200' FROM PROPERTY LINE r 50'10' A B SV1 �JF–CO"Y3� 25'-5" SV2 20'-10" 17'-1 " DC1 A AY F' EN �a G GRAVEL 1 DRIVEWAY' aRPORT 1 NEIGHBORING SEPTIC IS > 75' FROM \ PROPERTY LINE �I Tank Replacement As Built Prepared for ROBERT & NAN SICKLER 18610 Sue Tawn Dr Chugiak, Alaska 99567 SUE TAWN ESTATE #2 BLOCK 3 LOT 8 EXISTING 50' x 5' x 24" EFFECTIVE DEPTH TRENCH _--DOUBLE CLEANOUTS NEW 1530 GAL SEPTIC TANK, PLACED A MINIMUM 5' AWAY FROM DECK SUPPORTS OF FIELD I" OSP191370 EKLUTNA ENGINEERING, LLC DATE: 11/14/2019 19162 MOUNTAIN ROAD DRAWN: CLT CHUGIAK, ALASKA 99567 SCALE: 1" = 50' (907) 355-9820 PID: 051-511-34 SHEET 1 OF 2 MARK A B SV1 14'-5" 25'-5" SV2 20'-10" 17'-1 " DC1 18'-5" 26'-8" DC2 20'— 0 " 27'-7" SUMP 68'— 0 " 77'-9" • �'J,: •, •, % AV Mir 49TH °: ♦f i........... .. ......................P ..... . f............................................ ..� ♦C's,CURTIS TOWNSEND: R �jC' ' Na. C 11 04 °� NOTES: 1. () RECORD DIMENSIONS PER PLAT 76-268. 2. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST. 3. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY DATA SHOWN BE USED TO ESTABLISH ANY FENCE, STRUCTURE OR ANY OTHER IMPROVEMENTS. ELECTRIC TRANSFORMER OVERHEAD UTILITY 4. ALL VISIBLE ABOVE GROUND FEATURES OF THE EXISTING �9• SEPTIC SYSTEM WERE LOCATED AT THE TIME OF SURVEY AND ARE SHOWN HEREON. ASBUILT - NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF LOT 8, BLOCK 3, SUE TAWN ESTATE ADDITION NO. 2, PLAT NO. 76-268, ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE IMPROVEMENTS AS DEPICTED HEREON EXIST AS SHOWN IN RELATION TO THE PROPERTY LINES. EASEMENTS OF RECORD OTHER THAN THOSE SHOWN ON RECORDED PLAT No. 76-268 ARE NOT SHOWN HEREON UNLESS OTHERWISE NOTED. I DATE: 11/13/2019 I FB: 2019-3 GRID: NW 1060 1 DRAWN: DMR I SCALE: 1" = 50' FILE: OF At,, ,k *: 48TH •"YA.lY.�..•.. • Dayna M. umfelt �+���s• No 13 `S 15.50, 00„ Wi USURVEY & MAPPING 2890 S. BARNYARD CIR., WASILLA, AK 99654 DAYNA RUMFELT (907)301-5177 - DAYNAOLAVENDERSURVEY.COM SCALE 1" = 50'1 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program e',. PO Box 196650 4740 Elmore Road s 1VAnchorage, Alaska 99519-6650 Phone: (907) 343-7W4 Fax; (907) 343-7997 .•..al .' ' htlp://www.muni.org/onsite RyCi1tlR Fit On -Site Wastewater Disposal System Permit Permit Number: OSP191370 Effective Date Work Type: SepticTank Upgrade Tax Code Number: 05151134000 Site Legal Address: SUE TAWN ESTATE #2 BLK 3 LT 8 GA060 Site Mailing Address: 18610 SUE TAWN DR, Chugiak Owner: SICKLER ROBERT V & NAN M Design Engineer: EKLUTNA ENGINEERING, LLC` This permit is for the construction of: ❑ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy Expiration Date Lot Size in Sq Ft: Total Bedrooms I,,% C n t 3, r�. t04'w f Department 8/22/2019 8/21/2020 11.11*1K ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing r i Special Provisions: Tank shall be located a minimum of 5 ft from any deck/stair supports (if deck is over 30" high) and a minimum 5 ft from the existing drainfield. t� Received B� Issued By: Date: Date: 3 FIOUNICIPALITY OF ANCHORAGE Development Services Department Phone: Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-511-34 Property owner(s) SICKLER ROBERT V & NAN M Mailing address PO Box 670887 Chugiak AK 99567 Site address 18610 Sue Tawn DrChugiak AK 99567 Day phone 907.250.9966 Legal description (Sub'd., Block & Lot) SUE TAWN ESTATE #2 BLK Legal description (Township, Range & Section) Lot Size 65,812 Sq. Ft. Number of Bedrooms 3 3LT; 8 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank El Upgrade El (D) ❑ Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. 1 further certify that this is in accordance with aodicabIjelMunicii)al Codes. 7",/ t �l/ (Signature of property owner or authorized agent) C Permit/Rush Fees: Waiver Fees: Date of Payment: 0--kI Date of Payment: Receipt Number: COTI ';% Receipt Number: Permit No. Gr;2e LQ 1310 Waiver No. GADevelopment Services\Building Safety\0n Site Water and WastewaterTormsUient Forms\Permit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191370, Rebecca Carroll, 08/22/19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191370, Rebecca Carroll, 08/22/19 NAME MAILING ADDRESS LEGAL DESCRIPTION (,~,¢' MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAl- PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELl_ INSPECTION REPORT PHONE ~NEW LOCATION OK I m ILiq. cap~ci~g~lons IF HOMEMADE: Inside length ~ ~ ~ Manufacturer ~--= I Well ~ O Foundation ~ DISTANCE TO: ~ ~ O No of lines Length of each ine Tota ength of I nes m Length Width Depth ~ Type of crib Crib diameter Crib depth ~ DISTANCE TO: Building foundation Sewer line m Well Building foundation ~ DISTANCE TO: _ Class Depth Driller Distance to lot line Septic Material I~ Nearest lot line ~ Trench width ~ Oi.¢hes inches NO. OF BEDROOMS PERMIT NO. No. o~ compartments~ Liquid depth PERMIT NO. Liqui~ capacity in gallons PER I~ NO. ~ Distance between lines Total effective absorption area PERMIT NO. ~ ~' Total effective absorption area Nearest lot llne OTHER PIPE MATERIALS pvc SOIL TEST RATING INSTALLER REMARKS ,3% m APPROVED DATE LEGAL 72-0~B (Rev. 2/78} PERHt T NCL F!F'F'L I CFIIgT L D C ~. T ! O N LEGFt!... L,:,E,_. SUETFIP.!N T'¢PE OF ':;Flit FdE~E;Cff(:PT!O!",I ¢'"'"" ......... .......... =¥.:IEI~ ILl;; C, RRI?',!FIELC, IH ..... I 1 ?.!.HEF'~' OF:' E:EDFrEK3HS = < _.,L..~.L F:FITING ,":;o F'T/BR>,'-' ~..:tO _,L .ti.. FtFr:qCF,.'.~:'TiOi".i .:,~ =,..:I1 THE REL:!U!RE[:, ......... '--T;~'1= "l:~ THE c- ..... ''6"t"F" T,=.,. TFIE LENGTH E:[HEN'.:~ION IS THE LENGTH <llq FEET::, OF THE TRENCH OR [:,R¢~!NF!ELD. THE DEPTH OF FI TRENCH OR PZT 15 THE DISTFINCE BETHEEN THE :SURFRCE OF THE GF:OUND faN[:, THE DO'TTOH OF THE E:4CR',,,'RTION <ZI'.4 FEET:). THE GRF!'¢EL E:,E:F'TH IS; THE HINIHUH DEPTH OF EiF'.RVEL DETP.IEEN THE OUTFF!LL F'tPE RI'..IE:, 'THE BOTTOH OF THE EXCRVRTION ,::IN FEET). F'ERf'I! T FtPF'L I C:RNT HFIS THE RESF'ONS: I E: I L !"r"~.' 'TO ! f.,IF'-ZlPf,'l TH I'5 [:,EF'FIF:THENT [:,l..IF: ! BIG THE F!ELL=, FC,JfFI-EHT TO TH!5 F'ROF'ERTU !~N[:, THE !NS;'T'F~I_LF!TION INE;F'EC:TIONS OF Fff.,!%.' "' NI_iHE:EF~: OF RESIDENZ:ES "FHRT THE: 1.4ELL !4IL. L BFiCKF I L.L ! NG qF FIN'-/ :, ~ :,, Ell 1.41 THEIIJT F ~ h!RL. I NSF'EC:T !2 ON F~NE:, RF'F'P.O'v'RL. EW TH I E; DEPRF'.TMENT 14IL. L E:E E%.IECrEC:T TO F'RO:SEC:UT:[ON. MiNiHUH [)!S'TF'!NC:E BET.tqEEN R .[,.tEk_T_. FIND FIN'¢ ON--SITE SE!.,!RGE DISPOE;FIL S"r'$TEH i~; :LETO FEET F'OR I::l PRi',/RTE I.,.!ELL OR :L56 TO 200 FEET FROH R F'UE:LZC IqEL. L DEPENDING LiF'ON THE 'T"T'F'E OF PUBLIC FIELL.. i"IIN!HUH [:,ISTF~NCE F'ROH R PRI',,,'RTE P.!ELL TO FI PR:[VRTE SEP.IER LZNE IS 25 FEET RND TO R COMHUNZ-f'"r' SE!.4ER LINE Z:S 75 FEET. !4ELL LOGS RRE REC!t.JZRED F~i"~D MUST E~E RETURNED TO THE D, EPRRTMENT kIZTHIN 30 DR'CS OF THE I.,IEL. L COfdPLETZON. OTHER REQUZF'.EI'dENTS i"!F?¢ RPPL.'¢. S;F'ECZFZCRTZON5 RND CONSTRUCTZON DZRGRRI'dS RRE R',,.'RZL. RE~L.E T'O ZIqSUF'.E PF'.OF'EF: ~NSTRLLRTiON. I CERTiF"r' THFI'T Z: I FiPi FFIMILtFIR WITH ]"HE REQUIREHENTS FOR ON-".S!TE SEI4ERS RND WELL5 ~S SET FORTH BU THE MUNICIF'RLIT'?' OF RNCHORRGE. 2: I HILL :[NSTFiLL THE 5"r'STEM IN [~CE:ORDRHCE P.!ITH THE CODES. ~:: I UNDERS'TRND THRT THE ON"'-SITE SEFIER S"r'S'TEH I"!R'¢ REC~UIRE ENLRRGEHENT IF THE RESIDENCE IS REMOE:,EL. ED TO ZNCLUDE HORE THRN ~2: BEE:,ROOH5. 'CUR..qCff [bK~ C-:,Q,-'- F.,-"-'""' -.:,.: .) o MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264*4720 SOILS LOG - PERCOLATION TEST [] PERCOLATION TEST SLOPE : ko¥ SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14- 15- 16- 17- 18- 20- COMMENTS PERFORMED WAS GROUND WATER ENCOUNTERED? o P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) TEST RUN BET EEN FT AND -- FT CERTIFIED BY: ATE: 72-008 {6/79) by DOC CO. dba SULLIVAN WATER WELLS P.O. BOX 670272. CHUGIAK, ALASKA 99567 · TELEPHONE 688;2759 OWNER OF LAND . ADDRESS LEGAL DESCRIPTION DATE - Started Ended PERMIT NUMBER ' W STATIC LEYELOF ATER FT. DRA DO~,N FT. GALS. PER HR KIND OF FORMATION: From (~-) Ft. to o~ Ft. From --? Ft. to Ft. From ~'[ Ft. to '?'<[ Ft, From'7<~ Ft. to fl !~) Ft, From Ft. to Ft. From __Ft. to . Ft From. Ft, to_ Ft. From Ft. to _Ft. From Ft. to_ Ft. From~_ Ft. to Ft. From ~ Ft. to___.Ft. From ~ Ft. to Ft. From t Ft. to Ft. From Ft. to .Ft From Ft. to Ft. From. t Ft. ro Ft. From ~ Ft. to Ft. From.___ Ft. ~o Ft. From_ Ft.!o Ft. ~'~ ~ From Ft. to Ft. From Ft. m F~ From Ft. to__ Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to From Ft. to Ft. From _ Ft. to Ft. From Ft~to From Ft. to Ft From Ft. to Ft. From FL to Ft. From Ft. to Ft, From Ft. to MISCL. INFORMATION: JUN 1 1 1998 Municipality of Ano~_orage Dept, Health & Human DRILLER'S NAME PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW970108 DESIGN ENGINEER:DUMMY COMPANY OWNER NANE:SICKLER ROBERT V & OWNER ADDRESS:18610 SUE TAWN DR CHUGIAK, ALASKA 99567 DATE ISSUED: 5/28/97 EXPIRATION DATE: 5/28/98 PARCEL ID:05151134 LEGAL DESCRIPTION: SUETAWN ESTATE 02 BLK 3 LT 8 LOT SIZE: 65812 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: ; ~0''W / ,/ ~5-/¢LIILT dUI~V'~ Y LOT' ~, ¢6/4. '~ TAY'/N ~6TA?~ /4P/)F/V ~/O 2 Madlng Address ~ Multiple Family No. of Bedroor~s [] Other Water Supply '~ Individual ATrACH WELL LOG. A well log is required for all wells drilled since June 1975. Community Fdr wells drilled prior to that date, give well depth (attach Icg if available). El Public Utility Sewer Bisposa ;2. Public Ulility When Oonneeted to Public Utility: NOTE: ~HE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED; Time Time,' , ~ Time Ti e Date Date , , Date ' Date ~ Inspector Inspector - Inspector . Inspector Fierd Notes: ~[~ ~" (~U ~ .. - MuNICJpALI~ OF ANCHO~O~ ~ C* O. ( DEPT. OF H~ALTH O~ ~~' ~NVIRONM~NTAL p~oTECTION RECEIVEg (~) APPROVED BEDROOB81 - ~ 'CONDITIONS OF APPROVAL ( ) DISAPPROVED Soils Rating Date ~wer Installed Well TO bsorption ~ Well Log Received ~0~ ~ ~ Area ~ 0 ~_e~a WelltoTank ~'! O~ ~ Septic T~k Size Septe.~ber 16, 1983 }~ruce Vadla Box 294 Girdwood, Alaska 99587 Subject: Lot. 8, Block 3, Sue 'Pawn Est ~i2 'Approval for the individual sewer and water facilities cannot be granted until the following items have been co~pleted: o 2'he old %~ell must be property sealed and abandoned. Please notify this Departa]ent for a reinspection when the noted discrepancies have been corrected. If there are any further questions, please call ~.his office at 264-4'720. Sincerely, ~. ,: ~o. 422 - '~";RILLING 'CO. CHUGIAK, ALASKA 99567 PHONE 688-3199 DESCRIPTION OF WORK LEGAL DESCRIPTION / ~v¢"~¢-4 ~¢~ ~¢&;. LEGAL OWNEI~ ¢BA~ K OR LEN DiNG iNSTITUTIONS CU RRE NTLY HOLDING OF~D OF TRUST HOME PHONE ~NORK PHONE WELL NUMBEE~ SERIAL NUMBER I DEPTH MATERIALS AMOUNT ~4ATERIALS All charges shall be eaid in full within ten days un/ess other arrangements are made prior to work. The customer shag pay interest at the rate of two (2) percent per montll on any amount not paid within ten days. Failure to pay may result in a lien against the property. THIS IS A RIGHT TO LIEN SAID PROPERTY DESCRIBED ABOVE CUSTOMER SIGNATURE