On-Site Wastewater Disposal System and/or Wel~ Inspection Report
Permit Number: ,~uJ 95'o101 PID Number: O/E' 077. 17
N.~e: X/Dc b.J~_~AcA5 Wastewater System: C2 New '~Upgrade
,oc~.,,: ~TZ-o -E', 97'~ A~,~u~- ABSORPTION FIELD
Phone: j I~I.Q.~_~. ~ Deep Trench ~Shallow Trench ~ Be~ rl Mound r'l Other
LEGAL DESCRIPTION /. Z-
WELL: D New [~ Upgrade ~' Pt. I
C=assdicatlon (privam. A,B,C~: Total negro: Casco To: Total aiosor priori a~ea: Pipe rnamrial:
SEPARATi O N D ISTAN CES ~ septic Q Hal.lng Q S.T.[P.
Water >/00' )/0" >100 LI~ STATION
LOt I ~ ~ ~ ~ O t Size in gallons:
Remarks: ~ ~N~ ~AIV~ O~A~4~ BENCH MARK
,nspectionspedorm~ by: ~' ~,~A .Dates:Is, ~
Depadment of Hea th and im~ Se~ices approval '"'. :,'~- .~-,~.
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~)0~5'5"'0~0t PlO Number: 01~ OTZ.. 17
__of ~
' Municipality of Anchorage Pag.$
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · 'l'eiephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: '~("JC~5"OlOI PiE) Number: ~/~' 07Z.- 17
of 3
4 II1 $-I''/ I I /~-
d
.I
,I
I" = lOt
NOTE: Only the Drain
field was Replaced This
Project. Existing Con-
crete Septic Tank Was
Verified~ sound and Reus~
MUNICIPALITY OF ANCHOP~AGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE)
PAGE 1 OF 1
PEP, MIT
PERMIT ~ER:SW950101
DESIGN ENGINEER:ANDERSON ENGINEERING
OWNER NAME:WILLIAMS VOL G
OWNER ADDRESS:5720 E 97TH AVE
ANCHORAGE, AK 99516
DATE ISSUED: 6/02/95
EXPIRATION DATE: 6/02/96
PARCEL ID:01507217
LEGAL DESCRIPTION:
SU/vS~IT ESTATES BLK
2 LT 2
LOT SIZE: 16200 (SQ. FT.)
~ER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AiXD HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
DATE:
Rick Mystrom,
Mayor
MuniVipality of AnchSrage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
June 2, 1995
Michael E. Anderson, P.E.
Anderson Engineering
PO Box 240773
Anchorage, Alaska 99524
Subject: Waiver Request
Waiver Request
for Lot 2 Block 2 Summit Estates
~WR950019, PID ~019-072-17
Subdivision
Dear Mr. Anderson:
Your request for a waiver of the required 10 foot separation
between a septic system and a lot line has been approved. The
waived distance is the leachfield to 3 feet from the west property
line.
existing septic
This approval applies to the
separation only. Any future upgrade to the septic
require all separations be met or another approval
department.
~~erely, ,m
es Cross, P.~.
~;~a~] Manager
On-site Services
system lot line
system will
from this
ljw #7
ANDERSON ENGINEERING -
P.O. BOX 240773
ANCHORAGE, ALASKA 99524
May 25, 1995
RECEIVED
MAY 2 6 1995
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Municipality el Anchorage
Dept, Health & Human Services
Subject:
Lot 2, Block 2, Summit Estates Subdivision
Septic System Lot Line Waiver
Dear Onsite Services Engineer:
The location of the existing well on the subject lot severely limits
the area available for a replacement absorption trench. The new
trench must therefore be placed within 3' of the lot line as shown on
the attached Site Plan. We hereby request a waiver be granted
allowing the new trench to be located 3' from the west property line.
The trench will be at least 30' from the absorption system currently
in place on Lot 3 immediately to the west. In addition, it is more
than 50' from the system located to the south. Neither of the wells
on these lots is within 100' of the new trench. Placement of the
new trench at the proposed location will have no impact on the
septic systems or wells located on adjacent lots. I therefore
recommend the lot line waiver be granted.
Sincerely,
Michael E. Anderson, P.E.
NE
-Rec.
I0' UTILITY EASEMENT
LOT 2, BLOCK 2, SUMMIT ESTATE-~
SCALE 1" = 20'
IOTE:
Existing Crib to be Completely Excavated with
Contaminated Material Buried Onsite.
Concrete Manhole to be Reused After Verification of
Tightness and Repair of Baffle.
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, ALASKA 99524
May 22, 1995
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject:
Lot 2, Block 2, Summit Estates Subdivision
Septic System Design
Impacts to Adjacent Properties
Dear On Site Services Engineer:
The absorption crib on the subject lot has failed and must be replaced. We
hereby apply for a permit to upgrade the system by installing a wide
absorption trench in the same location as the crib. All remanants of the
crib including contaminated soils will be removed and buried onsite with
the ensuing cavity backfilled utilizing Lake Otis Gravel (Sand). The exsiting
septic tank will be verified for tightness and resused after the baffle inside
the tank is repaired.
Work will take place at the location shown on the Site Plan. The placement
of the well on the lot allows only a small area for the new trench near the
southwest corner of the lot. A lot line waiver will be required to take
advantage of the remaining useful area. Placement of the absorption
trench in this area will not impact adjacent septic systems or wells. The
existing septic tank will remain within the 100' protective well radius.
Since it was originally placed in 1970 it has grandfather rights to stay at
this location.
We noted in our file search a new septic system was installed on Lot 1,
Block 2, Summit Estates in 1992. At that time a separation distance waiver
was issued for the septic tank and well on that lot. The septic tank on Lo[
1, however, is within the i00' protective radius of the well on Lot 2. Since
the well On Lot 2 was in place prior to construction of the septic system on
Lot 1, the owner of Lot 1 is responsible for obtaining a separation distance
waiver from the well on Lot 2. Please review your files concerning this
matter.
Lot 2, Block 2, Summit Estates Subdivision
May 22, 1995
Page Two
Once construction is complete the ground surface on the lot will be
regraded to its present condition. Surface drainage will not be impacted
by the upgrade to the septic system.
If the system is installed as designed the following statements may be
made:
The system, if constructed as designed, will have no adverse impact
on the wells in the area or those to be constructed in the future.
4
The system, if constructed as designed, will have no
on existing septic systems in the area or those to be
the future.
adverse impact
constructed in
The system, if constructed as designed, will have no adverse impact
on reserved space, either surface or subsurface, on any lots located in
the area.
The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area. The current drainage pattern will
be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
FAR NORTH BICENTENNIAL / HILLSIDE PARK "'~'
5410
LOT 2~ BLOCK 2~ SUMMIT ESTATES
LOCATION MAP
a-st
9 ?thl Ave.
( 8 9 t-6T',. F
NOTE:
P
CK
I
0
Iz L~I
NE
Rec.
10' ':UTILITY' EASEMENT
LOT.2, BLOCK 2, SUMMIT ES~
SCALE 1" = 20' ~07":.::':~
Ex st ng Cr b to be Completely Excavated with ~¢})'{/,~d,.~
Contam nated Mater a Bur ed Onslte. ¢~t~:,
Concrete Manho e to be Reused After Ver~flcahon of ,~..c,. r,..~ ~., .~:>~.~
T ghtness and Repa r of Baffle. ~,.. ;,~ ~ ~,~,'.;~'
Lot 2, Block 2, Summit Estates Subdivision
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Three Bedroom Home Wide Trench System
Perc. Rate: 4 Min./Inch 1,000 Gal. Septic Tank
Application Rate: 1.2 GPD/SF 4' Drain Rock Beneath
Reduction Factor: .5
(Existing)
Pipe
3 Bdrms. X 150 GPD / 1.2 GPD/SF = 375 SF of Absorption Area
375 SF / 5' Wide = 75' LF X .5 (Red. Factor) = 38.5 LF Trench
Therefore: Construct a Wide Trench System With One Lateral a
Total Length of 40'. Place 4' of Drainfield Rock Beneath the
Lateral. Place Distribution Pipe at 3' Below Ground Surface.
Repair Baffle in Existing Concrete Manhole.
TYPICAL WIDE TRENCH SYSTEM
(NO SCALE)
Existing Log Crib and Contaminated Soil to be
Removed and Buried Onsite.
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street. Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION;
?-~
1
11
12
13
14
15
16
17,
18-
19-
20-
COMMENTS
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
SLOPE
Depth to Water After. I
Monitoring? fv~,,,j, ~ Dato:
SITE PLAN
Gross Net Depth to Net
Reading Date Time Time Water Drop
7 : 0 5 : ~ o '-/': '+'=J I ~, ,15 /. 3 ~
PERCOLATION RATE 4. (minutes/inch) PERC HOLE DIAMETER __
TEST RUN BETWEEN ~* FT AND ~ FT
PERFOBMEO" : , ' TH?ST.ST ASPERFORMED,N
· ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE. DATE:
72-008 (Rev. 4/85)
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: Lot 2, Block 2, Summit Estates Subdivision
GENERAL:
The scope of this project includes the removal of the
existing absorption crib, verification of the integrity of the
existing septic tank and repairs to the baffle and the
construction of a wide abosrption trench to serve the
existing three bedroom home.
Construction shall be in accordance with the approved site
plan, design drawings, Municipal Permit with any special
provisions or conditions, and all applicable State and
Municipal Wastewater Disposal Regulations.
The Contractor shall be responsible for obtaining all
underground utility locates and for the layout of the septic
system and verification of the location of all lot lines.
Unless specifically agreed otherwise, the contractor shall
be responsible for final grading areas subsequently
depressed from soil settling. Property owner shall be
responsible for revegetation of affected areas unless
specifically agreed otherwise.
Contractors installing wastewater disposal systems must
be certified by the Municipal Department of Health and
Human Services for system installations. Owners installing
their own systems must receive prior approval from D.H.H.S.
before beginning system installation.
SEPTIC TANK INSTALLATION/REPAIR
1. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts
for pumping access.
2. The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
Lot 2, Block 2, Summit Estates Subdivision
May 22, 1995
Page Two
3. All standpipes on the septic tank shall extend a minimum of
12 inches above final grade.
4. Septic tanks installed without 4' of cover shall have a
minimum of 2" of direct burial insulation.
A foundation cleanout shall be installed one to four feet
from the building foundation. Two cleanouts shall be
installed between the tank and the drainfield. The first
cleanout shall be located on undisturbed soil not more than
10' from the tank. The first cleanout shall be to clean
toward the drainfield. The second cleanout shall be to clean
toward the tank.
6. Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
DRAINFIELD CONSTRUCTION:
The drainfield shall be constructed to the dimensions shown
on the design. The bottom of the trench shall be within 2"
of level. The trench shall not be installed on a slope greater
than 10%.
Distribution piping must be placed level with perforations
down atop a level bed of drainfield rock. Rock should then
be placed over the pipe to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between
the drainfield rock and the natural soil backfill.
4.
Monitor tubes must be
locations shown on the
must be perforated.
4" in diameter and installed at the
design. The portion below ground
5. Contractor shall verify the septic tank and drainfield are a
minimum 100' away from any water wells in the area or
200' from the community well.
Lot 2, Block 2, Summit Estates Subdivision
May 22, 1995
Page Three
Direct bury insulation must be placed over the distribution
system if less than 3' of backfill depth is available. Finish
grade over the trench must be mounded to prevent
settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the
drainfield rock. Contractor shall verify this condition prior
to placement of the rock. All pockets of unacceptable
materials must be removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a Municipally approved
septic tank manufacturer.
2. The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.O.
(perforated and solid), ASTM F810 or H.D.P.E. (perforated, but
not solid) and ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial
polystyrene (Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
A permeable geotextile fabric (Typar, Mirafi or equal) must
be installed between the final drain rock layer and the
native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than
3% passing the #200 seive.
Lot 2, Block 2, Summit Estates Subdivision
May 22, 1995
Page Four
INSPECTIONS:
A minimum of two inspections are required by Municipal
Ordinance. These inspections must be conducted under the
supervision of a professional engineer registered in the State
of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation
of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement
of the geotextile fabric, gravel, distribution piping,
standpipes, cleanouts and insulation. No backfill should be in
place at the time of inspection.
Contractor shall provide a copy of all field survey layout and
construction notes for use in preparing the certified as-built
of the completed system.
REMOVAL OF EXISTING ABSORPTION CRIB
The existing absorption crib must be removed in its entirety
prior to installing the new trench. All contaminated material
removed from the old trench can be buried onsite providing it
is 4' above the water table. The cavity resulting from the
excavation must be backfilled with clean sand. An acceptable
source of this sand is Lake Otis Gravel (product name is
"gravel", but the material is actually sand). The existing crib
is estimated to be 12' in length by 14' in width and may extend
from 4' to 10' below the existing ground surface.
BIRCH RDA D
__+_~ .......... --
I ~, / ~.~ .f:....~.,~,.~,~?~
, ~ / ~i,~... t,/ ...',';:;,1., I
I I ,' , ~Y ~ '~,~, '< ~ I
~ :..:
120.00 120.00 120.00 120.00
~q.oo
J
120.00
2
120.00
120.00
50
120.00
120.00
Avenue
SBg'59'OO"W~ 530.00 HVL__
t20,O0
/G
120.00
l~O,O0
17
120.00 120.00
i98TH Avenue
120.00 120.00 120.00 120.00
¢ J 2 4 1
12o.oo 12o.oo ¢-. J! [.,. "~o.oo 12o.oo
?
Avenue
120.00 120.00 120.00
NSg'57'OO"E 610.00
/¢
t20.O0 IZO.O0
230.00 270.00
50
/~..-~ Lease Lots
The Municipality of Anchorage does
not worronl the accuracy of mops
or data provided nor their
suitability tar any porticub
application. The product or
service which you have received is
based on a version of data which
is maintained and was developed
for lhe internal use of [he
Department of Public Works. Ther,
ore some errors in the database.
This mop or data may not meet'
needs and may be inaccurate. Foi
any corredions or errors, please
call 786-8220.
DEPARTMENT 0~
PUBL lC WORKSI
BUILDING SAFET'
TECHNICAL SERVICE
RICK MYSTROM, MAYOR-
--.-,j / /
97.
GP~:'~TER ANCHORAGE AREA BOROU"'~H
{,,,,,/. HEALTH ,DE_PA~,TMENT L. '
327 EAGLE ST. ANCHORAGE, ALASKA 99501 2~-/25il
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
SEPTIC TANK:
J '~L~'~ --' NUMBER OF
.'7, ~ COMPARTMENT,)
DISTANCE FROM WELL '~ MATERIAL ~7'",~ '"~' ('7'~.
LIQUID CAPACITY //~ ~~-d~-/) GALLONS. INSIDE LENGTH ~I~SID~ WIDTH
LIQUID
DEPTH __
SEEPAGE SYSTEM: SEEPAGE PIT:
,' /
NUMBER OF PITS '/ OUTSIDE DIAME/ER ~ OR WIDTH IdLENGTH /'~ , DEPTH
LINING MATERIAL ' . DISTANCE FROM WELL BUILDING FOUNDATION'~
NEAR~ST LOT LINE TOTAL E~F~CTIVE ABSORPTION AR~A (WALL AREA) ~/ ~ SQ. FT.
TILE DRAIN FIELD:
NUMBER OF LI; ES AN E BE TRENC~ ' 6~TIVE
ABSORPTION SQ. FT., LENGTH OF EACH LINE.
DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL ~ENEATH TILE. IN. ABOVE TILE
WELL: TYPE~/~'/~f"L'~-~ , DEPTH ./~'~ ? DISTANCE FROM ! WATER ~ . NEAREST
~ , BUILDING FOUNDATION. /'~ ~ · SAMPLE
LOT LINE /0 ! NEARESt ~."" SEPTIC ,,7(~'/ SEEPAGE ¢~/ OTHER
~t , SEWER LINE ., TANK , SYSTEM , CESSPOOL ,.-~ , SOURCES
DISTANCES:
DIAGRAM OF SYSTEM
DATE
APPROVED
GREATER ',NCHOR,AGE AREA r ~ROUGH
'~' HEALTH DEPARTMENT %-~"
327 Eagle St. Anchorage, Alaska 99501 279-2511
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
NAM E 0 F APP LICANT~'~, / ,'~
RESIDENCE ADD R ES/~/
LEGAL DESCRIPTION
APPLICATION TO INSTALL: SEPTIC TANK f)~ , SEEPAGE PIT~.._., DRAIN FIELD , OTHER
F,N^NCED T.ROUG. ~ T0 BEgSTALLEO d ,¢d
PERCOLATION TEST RESULTS ANTICIPATED DATE OF COMPLETION
MA~UNG ADDRESS 5";~2~; ~ ~,,Zt¢~,~ PRONE NO.
LOCATION OF INSTALLATION ,-{-7
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
THIS IS TO SERVE AS '~/.'.// ~ ,PERMIT TO INSTALL A
AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED
,SEPTIC TANK SIZE /~'~ TYPE d~'~DIAGRAMSEEPAGE AREAoF SYSTEM
DISTANCES:
at I am familiar with the requirements of Greater anchorage Area Borough Ordinance No. 28-68 and that the
above described system is in accordance with said code.c-~, ~ ~¢. ¢ ...~ ~ .,~ ¢-- /~
~REATER ANCHORAGE~REA BOROUGH
HEALTH'DEPARTMENT
327 EAGLE STREET
ANCHORAGE, ALASKA 99501
CASE #
Performed For , ,,l~ ~. L nt~:, Date Perfor,m, ed
Legal Descriptlon~ Lot~BloCk
This Form Reports a. So~ls Log ~ ..... _
Soil Characteristics
Depth
Feet
Was Ground'~,ater Encountered?/?_~
if Yes. At Wha~
Date
Gross Time Net Time
Reading
Location Sketch
Net Drop
Proposed Instal~Seepage Pit . _ ~ Drain Field
Depth Of Inlet 3 C ~ , Depth To Bottom Of Pit Or
Test Performed B~,:. ,r ' _
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
On. Site Services Transmittal Sheet
LEGAL:
The attached paperwork has been reviewed and is being returned
for the following reason(s):
Discrepancy in legal description and/or owner name.
__Discrepancy in number of bedrooms.
Signature and/or stamp missing on ·
Show measured distances to sewers/wells, curtain drains
and streams within 200 feet of proposed system.
__Replacement disposal site not shown and/or tested.
Calculation error in design.
-- Show locations of all soils, percolation or water table
tests.
__ Proposed system too deep for soil test submitted.
__ Topographic information missing or inadequate.
__Narrative missing or inadequate.
__ Additional soil/perc test needed.
__ Sand filter requirements not satisfied.
__Water monitoring results missing or inadequate because
__ Incomplete; missing.
__Well log required.
Water sample unacceptable because_
Other T/tis
Please sup the necessary information and re-submit your
request. Your cooperation is appreciated.
Reviewer
Date
LEA VE THIS FORM ATTACHED TO PAPERWORK
/203-rev. 4/93
WR~ 970012
Date Received:
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
PID# 015-072-17 HA#
4-3-97
Legal Description: Summit Estate S/DJ Lot 2 Block 2
Engineer: Tobben Spurkland, PE
Permit
203 West 15th Avenue 203, Anchorage~ AK 99501
Applicant: Vol Williams -~ ~t{~ -~q~]
Waiver Requested: Waiver Cequest for private well on Lot 2 to ~eptic tank on
Lot 1
Criteria: 1. Geology:
Ao Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
~ E. Horizontal Separation
TOTAL:
2. Special Conditions:
Points:
3. Other:
Waiver is Granted: Waiver is NOT Granted:
List Conditions or Reasons for above:
Date:
· Note:
Rec #:
Did not pay fee
Amount:
Byi
$
Name of Reviewer
Date Paid:
T.SPURKLAND P.E.
203 W. 15th. AVE. SUITE 203
ANCHORAGE, ALASKA 99501
(907) 279-3916
Fax (907)-276-6013
Municipality of Anchorage
Division of Environmental Health
Department of Health and Soaial Services
820 1 Street
Anchorage, Alaska 99501
Subject: Waiver Request
Lot 2, Block 2, Summit Estate S/D
April 3, 1997
APR 3 1997
Municipality of Anchorage
Dept. Health & Human Services
Gentlemen;
We are applying for a waiver of the separation distance required between a residential well on Lot 2 and a septic tank
on Lot 1, Block 2, Summit Estate S/D. We request a twenty-five-foot waiver. This request is on behalf of Mr. Vol
Williams, the owner of Lot 2, who wants the violation resolved.
Lot 2 was developed in 1970 and Lot 1 in 1975. The developer of Lot I was in violation of the regulations at that time,
and the present owner is. The owner, Mr. Charles L. Willis, was notified of the violation by the Health Department
on June2, 1995, but has not responded to the notification, lt should be pointed out that the septic tank on Lot 2 was
installed when the required separation distance between wells and septic tanks was 50 feet. This tank is therefore not
in violation, and is not part of this waiver request. A well/tank separation waiver for the well and septic tank on Lot
1 was obtained in 1992.
No well log for the well on Lot 2 has been found. Well-logs for lots 3,4, and 6, Block I can be used to evaluate the
contamination potential.
The well for lot 2 is located inside the building. Contamination of the well by overland flow is prevented both by
topography and the house foundation. No evidence of subsurface contamination, as indicated by high Nitrates or the
presence of E-Coli has been found after 23 years of operation.
The justifications for granting this waiver are:
1. Water samples taken March 27, 1997 show a concentration of 2.1 mg/1 of Nitrates. This is well
within expected background values. No bacterial contamination was detected.
2. The well logs show several impervious layers between the surface and the intake of the wells.
4. The ground surface slopes away from the well. Overland flow of surface contaminants originating
at the septic system location will flow away from the well.
5. A waiver was granted for Lot I. This well has less protection than the well on Lot 2.
6. Conclusion: 1. Water quality sampling of the well shows that contamination of the well is not
taking place. 2. Inspection of the well log(s) bears out that surface contamination of the well is prevented by
several impervious layers. 3. Surface topography prevents any possible sewage overflow to reach the well casing.
N
3 2
,
I
.50 0 .50 100 1.50 200
SCALE: i" ~ 100 FL
--"~O£BEN SPU£KLAND ~/,OT 2,
205 W 15FH. AVENUE IF
ANCH. AK. 99501 I I
~ 279-5916
BLOC/( 2, SUMMIT~
YOL WILLIAMS II
5720 E. 97TH. AVE L~
WAIVER APPLICATION 'J
DATE: ~/ARCH 25, 1997 J
~ OR/D: Z~ST.I
SUEO202J. DWG 'J
PERMIT #
CT~E ESI ANCHORAGE
90? 561 5301 P.02/02
,~t~ CT&E Envlmnme~tal ~e~ices
Inc.
CT&E Ref.#
Client Name
Project Name/#
Client Sample ID
Matrix
Ordered By
PWSID
971482001
Tobben Spurkla,d P,E.
2/2 Summit Estate
Pokable
Drinking Water
Cliem PO#
Printed Date/Time 04/02/97 11:05
Collected Date/Time 03/27/97 I0:00
Received Date/Time 03/2.7/97 14:50
Technical Director: Stephen C. Ede
Sample Remark:
Sample collected by: T,S.
N{trate-N
Total Cotfform
2,1
0,100 m~/L EPA 300.0
col/100mL SHlg 9222B
03/28/97
05/27/97 RAM
'~,'=:' CTg:E ES[ AHCHORAGE 90? 561 55301 P,O1/O1
CT&E Environmental S~ ~~-~
i ~n ']~ g ' ,'- ~ Anchorage, AK99518-1605
~ .... V ',r"~SIDE~~FO~ COLL~CTI;YGZ.4M~L~ ~l: ~9~?)
R~AD i:VSTAOCTfO>5 u. ,~ ~ ~ F~; (907) ~61
5zCjST BE COMPLETED BY WAT~.~ $U,'PPLIER
~ F~VATE WATER SY$TEM
A,~. ~ D ~,T~:
SAMPLE
--I
TO BE
Ar, a!ysls shows this Water S.&MpLE to b~:
0 Samoi~ ~oo long in t~siq ~ample should
Date R~ceived ~__.
Anab'ti:al~Ielhod: ~ Mt' r,me :i,:;r
Month Day Y~ar
/~' Roudn¢
~ Repeat Sample (for routine ~ampl~
with lab ref. sO. _ ..... )
0 Special PurpO~
SAN;LPLF I.OuA ~
Time
Collected
97. I
BACTERIOLOGICAL WATER .&aNALYSIS RECOI:LD
E. Cot;
MMO-MUG Re~:ult: Total Coliform
MembraneFilt~¢: Olrc¢tC0unt ~
' Verificatioa: LTB ~GB
Colol5¢;/I00 mi
_ COLIFIRM
PART ONg Of
Parcel I.D. #
1.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
R1 ~-072-17 HAA#
GENERAL INFORMATION
Complete'legal description
Lot 2. Block 2. Summit Estates
Location (site address or directions)
5720 E. ~7th Avenue
Property owner vol willJ ams . ~" Day phone
5720 E. 97th Avenue Anchorage~ AK 99517
Mailing address
Lending agency Day phone
Mailing address
Agent .'.--' Day phone
Address
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: Th~,=,= (~)'v
TYPE OF WATER SUPPLY:
Individual well
XXX
NOTE:
Community well
Public water
If community well system, provide written confirmation from State A~EC attest-
inglto the legality and status of system.
4.- TYPE OF WASTEWATER DISPOSAL:
Individual on-site
'~ '?~" Holding tank -
Community on-site
"" *'Publi~ Sewer
XXXX
NOTE:
If community wastewater system, provide written confirmation from State ADEC ? -
attesting to the legality and status of system. ~ ...... -" ~ ' -
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shews that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State code,';,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm Anderson Enc~ineering Phone 522-77.73 _
Address P.O. Box 240773 Anchorage~ AK 99524
Engineer'i signature '~--~J--, ~' ~
Date 1214/98 .
DH7 SIGNATURE
Approved for ~%C~
Disapproved.
__ Conditional approval for
bedrooms.
Additional Comments
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchssem of home~;
and their lendifig institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or efialyze data before a certificate is .issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional 6ngineer's work.
Municipality of AnchorageRECEI~/~D
DEPARTMENT OF HEALTH & HUMAN SERVICL:~'C 7 ]998
Environmental' Services Division O~¢'lu'uc"-cJ P-aJ ~v 9.t.,~ ~ ch oragea~J -
825 L Street, Room 502 · Anchorage, Alaska 99501 ¢~'~n Se~ices
Health Authority Approval Checklist
LegalDescription: Lot 2, Block 2, Summit Est. ParcelI.D.: 015-072-17
A. WELL DATA
Well type Private
Leg present (Y/N)
Total depth 71 '
Sanitary seal (Y/N)
N
IfA, B, or C, attach ADEC letter. ADEc water system number
Date completed 1 970
· Cased to
¥
FROM WELL LOG
71 ' Casing height (above ground) 2 '
Wires properly protected (Y/N) Well Inside
Garage and Protected from Corrosive Elements.
Date of test
Static water level
Well production
g.p.m.
AT INSPECTION
11/28/98
38'
Wiring Not in Conduit.
5.0 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0
Date of sample:
12/2/98
Nitrate
2.06 mq/L Other bacteria 0
Collected by: MEA
B. SEPTIC/HOLDING TANK DATA
Date installed 1 970 Tank size
Foundation cleanout (Y/N) · N
Date Of Pumping 9 / 9 8 , ;,,:,; ;.~ ~ Pumper A- 1
~,'~
ARSORPTION FIELD DATA ,,!' i ~,
Date installed 6/95 Sbilrating (g.p.d./ft~orff~/bdrm)
Length 40 ' Width ~ ,~' ,
4 0:0-~ sF
Effective abso~3tion area:
I, 000 Number of Compartments 1 Cleanouts (Y/N). Y
Depression (Y/N). N High water alarm (Y/N) N
1.2
Gravel thickness below pipe
Monitoring Tube present (Y/N) Y
4 ' Total depth
Depression over field (y/N) __
For Three
Immediately after 51 6gal. water added (in.):
Absorption rate = U> 4 50 g.p.d.
If yes, give dat~e
System type . 5' Wide Trench
8.5'
N
bedrooms
22"
Date of adequacy test 11/?R/qP, Results (Pass/Fail). Pass
Fluid depth in absorption field before test (in.); 5.5"
Fluid depth 5" (ins) Minutes later:. 1,440
Peroxide treatment (past 12 months) (y/N) N
72-026 (Rev. 3/96)*
D. LIFT STATION None on Lot
Date installed
Manhole/Access (Y/N)
High water alarm level at*
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holdingtank on lot
Absorption field on lot
Public sewer main
Sewer/septic service line
Size in gallons
"Pump on" level at*
*Datum
75 ' On adjacent lots 86 '
> 1 00 ' On adjacent lots__86 '
N/A Public sewer manhole/cleanout
U25 ' > 25 ' Lift station N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation ;, 5 ~ Property line > 5 ' Absorption field
Water main/service line > 25 ' Surface water/drainage > 1 00 '
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line __.3.~ )Building foundation > 1 0 ~
Surface water > 1 00 '
Curtain drain None on Lot
F. ENGINEER'S Cl-'RTIFICATION
"Pump off" level at*
( Waiver
N/A
>5'
Wells on adjacent lots > 100 '
Driveway, parking/vehicle storage area
Wells on adjacent lots __ > 1 00
I certify that I have determined thru field inspections and review of Municipal r,
in conformance with MOA HAA guidelines in effect on this date.
Signature ~,~/c~(~
Engineer's Name Michael E. Anderson, P.E.
Date 12/4/98
Water main/service line > 25 '
>50'
issued 10/92)
HAA Fee $ ._
Date of Payment _
Receipt Number __(~ ~1
72-026 (Rev. 3/96)*
Waiver Fee $
Date of Payment __
Receipt Number __
DEC-04-1998 12:21
CT&E ESI ANCHORAGE
90?5615301 P.03/04
CT&E Environm ."J; ; vices Inc.
Laboratory Division
200W. Po~er Drive
Anchorage, AK 99518
Tel;(907) 562-2343
Fax:(907) 56t-5301
ChemLab Raf, #:
Client Name:
Project Name:
Client Sample ID:
Matrix;
98,6980-3
Anderson Engineering
n/a
Lot 2 Block 2 Summit Est,
Drinking Water
PWSID n/a
Sample Remarks;
Client PO#;
Printed Date/'1'lme:
Collected Date/Time:
Received Date/Time:
Technical Director:
n/a
12/4/98 12:00
'11/27/98 15:10
11/27/98 16:00
Stephan Ede
Released By;
Parametar
Nitrate
Results PQL Units
2.06 0,1 mg/L
Allowable Prep Analysis
Method Limits Date Date Init
E, PA 300 10.0 12/3/98 GCP
ENVIRONMENTAL ENGINEERING DIVISION /\PR 2 1980
Telephone 2644720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER F/~I~,~ V ED
MUNIClP.A'~fY OF ANCHORAGE ~2
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ....... ·
DEPT, OF I?ALTH &
825 L Street - Anchorage, Alaska 9g~01 ENVIRONMENTAL F;.OTECTIO~
i)IRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (J0) days for processing.
1. PR PERTYOW R , ~, PHONE _
MAI£1NG~DDR~SS v ~ _
PRO~RTY RESIDENT (If different from above) // ~/
MAI LI,N. G ADDRESS
STREET L O~;,~l-i ON ~ -
6. TYPE OF RESIDENCE NUMBER OF BEDROOMS
J~L SINGLE FAMILY
[] MULTIPLE FAMILY
7. WATER SUPPLY
iNDIVIDUAL*
[] COMMUNITY
PUBLIC UTILITY
[] One [] Four [] Other
[] Two [] Five
.,~ Three [] Six
depth (attach [o§ if available,)
B. SEWAGE DISPOSAL SYSTEM
~ INDIVIDUAL/ON'SITE** **If individual/on-site, give installation date i(~l~{~) .
If system is over two (2) years old an adequacy test is required
[] PUBLIC UTI LITY by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
THIS SIDE FOR OFFICIAL USE ONLY
DATE RECEIVEO
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE CATE
INSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
NUMBER OF BEDROOMS
1. TYPE OF RESIDENCE
[] SINGLE FAMILY
[] MULTIPLE FAMILY
2. WATER SUPPLY
[] INDIVIDUAL
[] COMMUNITY
[] PUBLIC UTILITY
Connection Verified
3. SEWAGE DISPOSAL SYSTEM
[] I NDIVI DUAL/ON -SITE
[]PUBLIC UTILITY
Connection Verified
[]Septic Tank or [] Holding Tank
Size: /(~-r.) If Tank is homemade
give dimensions:
[] ONE [] THREE [] FIVE [] OTHER
[] TWO [] FOUR [] SiX
PERMIT NUMBER
DEPTH OF WELL
DATE DRI L[~ED
LOG RECEIVED
PERMIT NUMBER
DATE INSTALLED
INSTALLER
SOILS RATING
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AR EA
4. DISTANCES
WELL TO:
MATERIAL
Septi~ol~g Tank Abso~c~Area Sewer Line
Nearest Lot
Absorption Area to nearest Lot Line
Line
5, COMMENTS
~;]"'""~APPROVED FOR ,.~ BEDROOMS
B~'/'~DISAPP ROV E D ,/~..
DATE4 . ~ ~.. ~ BY(~e) ~" /~
LEGAL DESCRIPTION
72-010 (Rev, 3/78)
ADEQUACY REPORT
MATERIALS TESTING . QUALITY CON1-ROL
SOILS ENGINEERING
JOB NO. ACTL 80-1318
2204 Cleveland Ave. 710 ThirdAvel
RO. Box 10-1126 RO. Box 2540 DATE OF REPORT 4/22/80
Anchorage, AK. 99511 Fairbanks, AK. 99707
277-0251 452-1F'67, 456-5155 DATE OF TEST 4/20 4/21/80
LEGAL DESCRIPTION ' LOT 2, BLOCK 2 , SUM[v[TT ESTATES SUBDIVISION
OR_ SECTION , T N, R W., S.M. , ALASKA
PERFORMED FOR: REQUESTED BY;
Dynamic Realty Connie Yochimura
501 W. Northern Liqhts Blvd.
PHONE NO. 279-7611 PHONE NO.
TYPE OF SYSTEM ' I~ SEPTIC TANK - SIZE 1000 GALLONS
~ CRIB OR SEEPAGE PIT
[] LEACH FIELD
NUMBER OF BEDROQMS 3
SEPTIC TANK WAS PUMPED G~YES [] NO
1000+
ABSORPTION RATE: AVERAGE 24 HOURS GALLONS.
SURGE RATE: 450 GALLONS IN 1]- MINUTES.
NOTES & OBSERVATIONS:
TEST PERFORMED BY: BP-BN REPORT PREPARED BY: B APPROVED BY: J.R. .
' ~i~0 GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
O~ "C" Street, Anchorage,
Alaska
99503
274-4561
Date Received
/
Time of Inspection ,'~"'-~
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Approval requested by:
Mailing Address:
2. Property Owner:
Mailing Address:
3. Legal Description:
4. Location: ~ ,
FOR
u~/t/~ ~-~%~_x>~ Phone:
Well Data:
A. Type ~~~ B. Depth~~
C. Construction D. Bacterial Analysis
Sewage Disposal System:
A. Installed
C. Septic Tank: 1. Size
D. Seepage Pit:
B. Installer ~-~L ,~J J~
~000 ~J~, 2. Manufacturer~ ~ ~ ~ ~'
1. Absorption Area ~ ~ 2. Material ~
E. Disposal Field: Total length of lines
Distances:
A. Well to: Septic tank ?~ I C~
, Absorption area
Nearest lot line ~) ~'~' , Other contamination
B. Foundation to septic tank ~ ~P~°N'
, Absorption area
C. Absorption area to nearest lot line __l ~
, Sewer Lines ,
EQ-034 (1/74) Page 1 of two pages
Pa~e 2 of two pages - Re t for ApproVal oi~ Individual S~r & Water Facilities
Legal Description ~ ~ D_ ~ ~
Approval Valid for one year from date signed
reater Anchorage ArEa Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
Date
SIGNED
EQ-034 (1/74)