HomeMy WebLinkAboutSUMMIT ESTATES BLK 2 LT 7 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 1 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231114 PID Number: 015-072-12000 Dwelling: ❑® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 9 Upgrade Name Sean & Theresa O'Connell ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 5522 E 97TH AVE, Anchorage, AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-346-0104 THREE (3) GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot SUMMIT ESTATES BLK 2 LT 7 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ftz Ft. Well >100' TANK ®❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1,000 Gal. Surface Water >1 00 Material Number of compartments Lot Line >5' NA PLASTIC TWO (2) Foundation >5' LIFT STATION Manufacturer Capacity Remarks EXISTING TANK ABANDONED PER MOA CODE REQUIREMENTS Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank drainfield D3034 Installer TURNAGAIN ARM CONSTRUCTION LLC. Drainfield Co/MT D3034 Inspector GABRIEL THOMAS BENCH MARK (Assumed elevation) 100' ft Inspection1&7/28/23 8/1/23 Location and description dates:2"d SLAB UNDER GARDEN FAUCET 3'd 4`h ON-SITE WATER AND WASTEWATER SECTION APPROVAL 0\\ OF' A�gs�lt Conditional Approval: Date . TH *¢�r ..:---...........- rJJ Gabriel Thomas No.108505���� Septic System Approved Date � .� ��1�`��pROFESS10Np�.m'� Note: this approval does not include well permit requirements. (Rev 05/02/18) BLOCK 2 I I I -00' AS—BUILT: PROFILE C1 FROM HOUSE i�P�`G OF A`q l� 49 T—H .. ...... �• Gabriel Thomas + �F4� No. 108505Ad ih�� °ROFESSIONP' BLOC=K2 SUMMIT ESTATES BLOCK 2, LOT 7 BLOCK 2 AS—BUILT: PLAN / I BENCH MARK: SLAB ' OM UNDER FAUCET / 00 \ SWING TIE POINTS / TANK ABANDONED IN PLACE ,>e� _ ____ ___ INSTALLED NEW 1000----- O�v �C5° JT_ o t530 GALLON PLASTIC TANK— 1 (FEET) 10' UTILITY ESMT.) +/- 4 FEET COVER & INSULATION BOARD INSTALLED DOUBLE CLEANOUTS C2 C3 11 Cq INSULATION BOARD (2") NEW 1,000 GAL. PLASTIC SEPTIC TANK INVERT AT INLET CONNECTED TO EXISTING PIPING INSTALLED DOUBLE CLEANOUTS C6I C6 CT INVERT AT OUTLET CONNECTED TO EXISTING DRAINFIELD PERMIT NUMBER: OSP231114 PID NUMBER: 015-072-12000 BENCH MARK LOCATION: CONCRETE SLAB UNDER FAUCET ASSUMED BENCH MARK ELEVATION: 100' LEGEND: C — CLEANOUT R — RISER MT — MONITORING TUBE TO FIELD SCALE: NOT TO SCALE Sean & Theresa O'Connell Summit Estates Block 2, LOT 7 Anchorage, Alaska Gabriel Thomas, PE 12633 Glen Alps Road 907-317-8970 ]WG. WASTEWATER DISPOSAL SYSTEM AS -BUILT SITE PLAN AND DETAIL DRAWN BY: SCALE: AS Shown KT DESIGNED BY: DATE: 08/02/231 GKT tW lNG�IES 20.4' 33.7' C2 55.0' 64.7' C3 55.6' 66.1' R 60.9'174.4 C4 63.8'178.7' C5 63.6' 82.0' C6 62.5' 82.2' C7 59.1' 83.0' MT 81.5 109.4' cD o AS—BUILT: PROFILE C1 FROM HOUSE i�P�`G OF A`q l� 49 T—H .. ...... �• Gabriel Thomas + �F4� No. 108505Ad ih�� °ROFESSIONP' BLOC=K2 SUMMIT ESTATES BLOCK 2, LOT 7 BLOCK 2 AS—BUILT: PLAN / I BENCH MARK: SLAB ' OM UNDER FAUCET / 00 \ SWING TIE POINTS / TANK ABANDONED IN PLACE ,>e� _ ____ ___ INSTALLED NEW 1000----- O�v �C5° JT_ o t530 GALLON PLASTIC TANK— 1 (FEET) 10' UTILITY ESMT.) +/- 4 FEET COVER & INSULATION BOARD INSTALLED DOUBLE CLEANOUTS C2 C3 11 Cq INSULATION BOARD (2") NEW 1,000 GAL. PLASTIC SEPTIC TANK INVERT AT INLET CONNECTED TO EXISTING PIPING INSTALLED DOUBLE CLEANOUTS C6I C6 CT INVERT AT OUTLET CONNECTED TO EXISTING DRAINFIELD PERMIT NUMBER: OSP231114 PID NUMBER: 015-072-12000 BENCH MARK LOCATION: CONCRETE SLAB UNDER FAUCET ASSUMED BENCH MARK ELEVATION: 100' LEGEND: C — CLEANOUT R — RISER MT — MONITORING TUBE TO FIELD SCALE: NOT TO SCALE Sean & Theresa O'Connell Summit Estates Block 2, LOT 7 Anchorage, Alaska Gabriel Thomas, PE 12633 Glen Alps Road 907-317-8970 ]WG. WASTEWATER DISPOSAL SYSTEM AS -BUILT SITE PLAN AND DETAIL DRAWN BY: SCALE: AS Shown KT DESIGNED BY: DATE: 08/02/231 GKT OF ,0*.- '49TH 12yan G, Johnson- ��# ��� , Na 19 215 9 8/4/2023, • (l i p'�FESSDNA��1~ � I> 1\ \ \\ c/) c/) 00 � o0 LQT 8 BLOCK 2 0 \ mm o� o� EAST 97th AVE 60' ROW) \ (E. 89TH AVE PER PLAT »P-628) (S 89'59'00" W 120.00) �T �R1vEWA� _S 89'42' 10" W 120.41 pNA RET i WALLS 21,8' HOUSE u Li 19,3'y 100' WELL RADIUS LOT 7 \ / BLOCK 2 (PLAT 4P-628) k 07 ca c°° • \ TANK---*� u SEPTIC PIPE �F (10' UTILITY ESMT,) \ FENCE NEIGHB❑R F LANDSCAPING�<N1, \ —t—E——E—E—E—E—N 89'58'16" E (N 89'59'00" E LOT 11 BLOCK 2 ASPLS MORTGAGE LOCATION SURVEY NOTES: NO TITLE REPORT WAS PERFORMED FOR THIS SURVEY, EASEMENTS SHOWN PER THE RECORD PLAT. THERE MAY BE ADDITIONAL EASEMENTS NOT SHOWN HEREON. THIS MORTGAGE LOCATION SURVEY HAS BEEN PREPARED IN ACCORDANCE WITH ASPLS MORTGAGE LOCATION SURVEY STANDARDS. IT IS A REPRESENTATION OF THE CONDITIONS THAT WERE FOUND AT THE TIME OF THE SURVEY. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. THE INFORMATION CONTAINED IN THIS DRAWING SHALL NOT BE USED TO ESTABLISH ANY FENCE, STRUCTURE, OR OTHER IMPROVEMENTS. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. LOT 12 BLOCK 2 z / o / 0 o / w / o co / 'C/) / O / LOT 6 U, V BLOCK 2 om O D �z o� fv O K D L7 119.26' — E 't — E — E — E — E — E — 120.00') LOT 13 BLOCK 2 0' 30' 60' SCALE: 1" = 30 FEET AS -BUILT OF: LOT 7, BLOCK 2 SUMMIT ESTATES SUBDIVISION PLAT 9P-628 ADDRESS: 5522 E 97TH AVE, ANCHORAGE, AK 99507 LOCATED IN: ANCHORAGE RECORDING DISTRICT TIMBERLINE SURVEYING AND MAPPING DRAWN BY: R.G.J. 17035 BARONOFF AVE FILE NO.: 23.22 EAGLE RIVER, AK 99577 SCALE: I"= 30 FEET 907-242-5320 DATE: 8/4/2023 ry-an@timberlinealaska.com SHEET: 1 of 1 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231114 Work Type: SepticTank Upgrade - Tax Code Number: 01507212000 Site Legal Address: SUMMIT ESTATES BLK 2 LT 7 G:2437 Site Mailing Address: 5522 E 97TH AVE, Anchorage Owner: CIM REO 2021-NR1 LLC Design Engineer: Gabriel Thomas This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: >>Z1 CI1( o ,. Is, � v f 1)ei)al, till elit 6/1/2023 5/31/2024 Lot Size in Sq Ft: 18000 Total Bedrooms: 3 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: S .� Date: Date: I Z� MUNICIPALITY OF ANCHORAGE Development Services Department ©{� Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. U(S -C>7 Z Z 620o Property owners)LSi¢lU� UG�t ay phone �a�^3i;Z F1-2 Mailing address / Z G3� ��c'r�( /%S �d /� - 1'�k j-51 Site address SS Z Z F� %�_ tf / /j_ , � � e 11 c - Legal description (Sub'd., Block & Lot) Sv -" -S A7 5 Z & Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption_ Field ❑ Initial ❑ Single Family (SF) Ik Septic Tank Upgrade (w/wo AD U) Duplex (p) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable MuUi-ei'q-), Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: _ 3 li. Waiver Fees: Date of Payment: S 2 S 2 3 Date of Payment: Receipt Number: Receipt Number: ---- Permit-No---CE-310-2- 3-1-1 I __Waiver No-- --- GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc May 31, 2023 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Section 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 REFERENCE: Septic System Tank Replacement and Conditional COSA for Summit Estates Block 2, Lot 7 To Whom It May Concern: The existing three bedroom, aforementioned house is serviced by a private well and septic system. An adequacy test was performed on the existing, deep trench, absorption field on 05.25.23. The absorption field adequacy test results indicate that the existing system is functioning as designed and meets all minimum requirements to service the single family, three-bedroom residence. The age of the existing, 1,250 gallon steel tank, in the existing septic system is beyond its useful life and should be replaced with a new 1,000 gallon septic tank. Based on available historic records, the existing system appears to have been designed and constructed to service a four-bedroom residence. However, according to Municipal Listing Services (MLS) and the Municipality of Anchorage Property Tax records, the current configuration of the home has only three bedrooms. Additionally, based on information provided by the prospective homebuyer, there are no plans to upgrade the configuration of the home to support additional bedroom(s). As such, the replacement septic tank is proposed to be reduced to 1,000 gallons, from the original 1,250 gallon tank, as to meet the minimum requirements for a three bedroom residence. Attached is the proposed tank replacement design. Based on testing results, the absorption field appears to be functioning as required to meet the property's current wastewater needs. This property has an undocumented water well that has been servicing the residence. A well adequacy test was performed on this drilled water well and was shown to be capable of producing the required daily minimums. Water samples were also collected and submitted to a certified laboratory for analysis. Results of this water testing will be provided to the department upon receipt. At the time of the well adequacy test, an attempt was made to measure the total depth of the well. An audible alarm, water level measuring device, also used for the adequacy test, was lowered into the well casing until the line became slack at a depth of 117 feet below the top of the well casing. A camera inspection was not performed to verify this depth and this measurement is only informational. Assuming that a three-bedroom residence will house six people, the average load on the system can be expected to be 450 gallons per day or 0.32 gals/minute. During the system test, over 450 gallons of water were accepted into the system in 555 minutes, which exceeds the minimum acceptance rate. Since the residence was unoccupied at the time of the test, the absorption field was presoaked with over 2,000 gallons the day prior to the test. From my measurements, I can conclude that the system is disposing of effluent at an adequate rate. Field measurements of the monitoring tube indicate that it does not extend to the bottom of the effective, but instead only extends 44 inches into the documented 60 inches of effective depth. However, effluent levels never exceed the effective depth during the system test and adequate measurements reflecting system performance were successfully obtained, as discussed herein. I do not anticipate any adverse effects on neighboring properties by the installation of this new proposed 1,000 gallon tank, the decommissioning of the existing 1,250 gallon tank or the continued use of the existing absorption field. The existing septic tank has been in operation for over 40 years and has not resulted in any known adverse effects to neighboring water or waste water systems. If properly decommissioned in accordance with all applicable codes and within the allotted time permitted by this conditional COSA, this decommissioned tank does not and will not pose any imminent threat or health hazard now or when decommissioned in place as prescribed. The septic system and water well servicing this residence are not in conflict with any neighboring water wells or wastewater disposal systems. Drainage flowing onto and off the property will not adversely affect the performance of the proposed wastewater system, or neighboring systems. I am requesting a conditional, Certificate of On -Site System Approval. Conditions for approval are as follows: 1) The existing septic tank is to be pumped and retired in accordance with MOA codes and a new, 1,000 -gallon plastic septic tank, manufactured in accordance with MOA standards will be installed neighboring the decommissioned tank, with all necessary plumbing and cleanouts installed per the design and all applicable codes and standards. This work will occur within 60 days of homebuyers closing the loan for the residence. 2) Well water sample testing results are to be provided to the department upon their availability. If you have any questions, or require additional information, please let me know. Sincerely, Gabriel K. Thomas, P.E. 907-317-8970 STANDARD MORTGAGE SURVEY NOTE: THIS SURVEY IS PREPARED IN ACCORDANCE TO A.S.P.L.S. MORTGAGE LOCATION SURVEY STANDARDS. THIS SURVEY REPRESENTS SURFACE CONDITIONS FOUND AT THE TIME OF LOCATION SURVEY AND DOES NOT CONSTITUTE A BOUNDARY SURVEY. THIS SURVEY IS SUBJECT TO ANY INACCURACIES THAT A BOUNDARY SURVEY MAY DISCLOSE. THE INFORMATION SHOWN HEREON SHALL NOT BE USED TO ESTABLISH FENCES, STRUCTURES, OR OTHER IMPROVEMENTS. UNLESS GROSS NEGLIGENCE IS DISCOVERED, LIABILITY OF THE PREPARER IS LIMITED TO THE FEES COLLECTED FOR SERVICES IN THE PREPARATION OF THIS PRODUCT. OF. Ak j %I, / .. q . TH / ... �/ .. i,EAST 97th AVE (60' ROM G!vl0?9-Cr- (E. 89TH AVE PER PLAT #P-628) \ Max A. Schillmger % JFK LS-12039Alp 1, 5/13/2023AV (S 89 59 00" W 120.00 ). L1 DRIv ���fFSSIOS 89'42'10" W 120.41' A PHA LLW RET•i WALLS }max OO I I 21.8' 1 I I Q �AN1I��v H❑USE Q `� �� EMIR• w / 19.3' cn v� w v 000 w r CD C ; / c o \ / w� / CK / LOT 8 0 , �o \ \ o LOT 6 BLOCK 2 0 \ cn -n./ BLOCK 2 / mm �� o,m \ O C> �.�� LOT 7 BLOCK 200 (PLAT #P-628) \�y� %`��� o -----6 \� \ cn \ (10' UTILITY ESMT•) FENCE co -------- ----=�x�X—X---x- r---\C—------- NEIGHB❑R LANDSCAPING \ — —E-E--E—E—E—E—N 89.5$'16" E 119.26'-E- -E-E-E-E-E- - — — Q — (N 89'59' — = —120.00') LOT 11 �o LOT 12 LOT 13 BLOCK 2 co BLOCK 2 , BLOCK 2 ASBUILT DRAWING OF: 0 15 30 SCALE: 1"=30 FEET DATE: 5-13-2023 LOT 7 FILE: 5522 E 97TH AVE B L OC K 2 PROPERTY ADDRESS: 5522 E 97TH AVE, ANCHORAGE, AK 99507 SUMMIT_E S TAT E S LEGAL DESC- LOT-7,-BLOCK 2, SUMMIT ESTATES, PIAT.- P-828, A.RD. ALL POINTS NORTH LLC, PO BOX 4207. PALMER, AK 99645 TEL: 907-746-4185 –N-- —I—Summit Estates Block 2, LOT 7 Reference 41' Swing Tie For Min. Well Separation Install New Double Cleanouts Within '10' of Tank – Up and Downstream ®® Install New 1000 Gal Plastic Tank Per Code & 100' From All Wells. Note Min. 41' Swing Tie Radius From 1st CO Abandon Existing Tank in Place, Pump and Decommission Per Code 0 Measured Location of Drainfield: 111' Swing Tie from Well at Lot 6 54' Swing Tie from SW Corner of Garage \--Maintain 5' Min. Separation: New Tank to Field Notes: 1. ALL WELIS ONADJOIlVINGLOTS ARE TOBE 100'OUMEOFTHE PROPOSED TANK REPIACEMENT LOCATION. 2. NO SURFACE WATER NOTED WITHIN 100' OFTHEPROPOSEDTANK REPLACEMENT. 3. CONTRACTOR WILLENSUREALLSFPARATIONS To ADJACENT WELLS, SEPTICS, EASEMENTS, PROPERT LINES, ETC ARE NET 4. CONTRACTORWILL ENSURE NUNXvIUM2% SLOPE JNTO SEPTIC TANK �v OF AZ,4S�1 SEW INSTALLER TO ENSUf;E THE FOLLOWING: * -2 ll -I */ DECOMMISSION EXISTING SEPTIC TANK PER CODE 49 INSTALL NEW 1000 GALLON PLASTIC TANKAND PLUME§NG PERCODE .. 3. TAN KTOHAVE MIN.20'MANWAYRISERS. 4. TANK TO HAVE MINMUM COVER AND INSULATION PER CODE Gabriel Thomas 5. MAINTAIN S+FROM BOSTINGRELD No.108505 �`�/� 6. MAINTAIN 109+ FROMPRNATE WATER WELLS Sl 7. GROUNDWATER WASNOTENCOUNTERED ON ORIGINAL TESTPTT l�J`OpROFES5100—� 8. INSTALLWATERTrHT000PLNGsPERCODE epic uesign rrepared For: Sean & Theresa O'Connell Summit Estates Block 2, LOT 7 Anchorage, Alaska Gabriel Thomas, PE 12633 Glen Alps Road 907-317-8970 DWG. WASTEWATER DISPOSAL SYSTEM DETAILS/AREA PLAP DRAWN BY: SCALE_ AS Shawn KT DESIGNED BY: 05/26/23 I��$7tf�gjjrj��� Summit Estates Block 2, LOT 7 E��$9TFIn� PQmP-� -— --- �p� I MDC MDC= I I ' R� 1pp. EDUM \Reference 41' Swing Tie oo For Min. Well Separation Install New Double Cleanouts Within Abandon Existing Tank in Place, Pump and Decommission Per Code 10' of Tank - Up and Downstream / o u Measured Location of Drainfield: 111' Swing Tie from Well at Lot 6 Install New 1000 Gal Plastic TankU 54' Swing Tie from SW o Per Code & 100' From All Wells. Note to Corner of Garage Min. 41' SwingTieRadius From 1st CO - _ 1 _ C0 ° (10' UTILITY ESMT.) EDT]] °° OTS -- OTS] _ MCZM ° °° mcm \ MC`® 00C0 ° 100' z Maintain Well radii for neighboring / New Tank 5' Min. Separation: to Field lots 11, 12, and 13 -T Notes: 1. ALLVMJSONADJORaNGTATSARETOBE100'OUTSIDEOF"IHEPROPOSEDTANKREPLACEMENrLOCATION . 2 NO SURFACE WATER NOTED VJ HIN 100' OF THE PROPOSED TANK REPIACOVIENT. 5 30 3. CONTRACTOR WILLENSURE ALL SEPARATIONS TO ADJACENT WELLS SEPTICS, EASEMENTS, PROPERTY LINES, ETC ARE MET. 15 4. CONTRACTOR WILL INSURE MW WN12% SLOPE INTO SEPTIC TANK (FEET) Septic Design Prepared For: SEPTIC INSTALLER TO ENSURE THE FOLLOWING: Sean & Theresa O'Connell r G> I. DECOMMISSION D4STNG SEPTIC TANK PER CODE Summit Estates Block 2, LOT 7 rr . 49TH * 2 INSTALL NEW 1000 GALLON R STICTANKANDPLUMEIINIGPERCODE Anchorage, Alaska ' ' ' • ' • • ' • • ' • ' • • • 3. TANKTORAVE MIN. 20'MANWAYRISERS. Gabriel Thomas, PE 4. TEWKTOME MINIMUM COVER AND INSULATION PER CODE 12633 Glen Alps Road Gabriel Thomas / 5 �MAIN5+FROM DEnNGFIELD 907-317-8970 Dwc. 6. MAINTAIN 100+ FROM PRN/ATE WATER WE iS F� No.108505 . • 1� / WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN t �sj / ' • •-� 1 3 �,�� 7. GROUNDWATER WAS NOTE 40OUNTERM ON ORIGINAL TESTPrr DRAWN BY: i FP /3� L"' ��� SCALE: AS SI10Wn GKT 8. INSTALL WATERTIGI-F COUPLINGS PER CODE PROFESS\0N DESIGNED BY: DATE: 05/26/23 GKT  ~..~ MUNICIPALITY OF ANCHORAGE ~ · DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ~ ENVIRONMENTAl_ ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELl_ INSPECTION REPORT NAME PHONE []~N EW ] Ig~ ~' WEE$ L~')/ []UPGRADE MAILJNGADDRESS LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS ~ DISTANCE TO: IWell tO~ ~ AbsorPti~area Dwelling ~ PERMIT NO.  Manufacturer ~~ Matsri~ ~ ~o. of compartman~ ~ ~ Uq. capacltg in ~allons Inside Ion~th ~idth kiquld depth / ~0 IF HOME'DE: ~ ~ ~ DISTANCE TO: Well Dwelling PERMIT NO. O ~ Manufacturer Material Liquid capacity in gallons Foundati~-- ~ Nearest lot line PERMIT NO. ~ DISTANCETO:i Well / /~ Totallength~es ~ Trench width Distance between lines ~~ -- ~ ~ No. of lines~ Length of each llne ~ Top of tilo to finish ~ra~ ~aterial ben0ath tho Length Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ :lass Depth Driller Distance to lot line PERMIT NO. m Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING /50 INSTAELER REMARKS . .-':; ," 72-013 (Rev. 3/78) F'ERH]:T NO. F!F'F'LICF!HT Z[:F'F i.,.IELSE'¢ F'OE,,J,-,-" :].:'.::5'.1. _. ~...'a':a=" ~:a._. L OE:i:YI' :[ Eli'-,! '~ LEGRL L., E,~ SUh'IH.'[ T E:L':TF!TEL': LOT T"¢F'E ]DF .:,_~!L [..,.:,L R!: ! Il_, ,I --:,~ =,, .h_.'l~._, : TRENCH.. . :~;iZ;:ZiE '?'_4 999::9 !E;C,:!LiRRE FEET ['![~::':; :[ PiIJPf i'.g_It"IE~E:F: OP DE'DF? THE .,b:.':E.g!UZF.:E:E:, '-::,.:ZE C!F 'THE THE LE?,!0'.q4 r. DIHE?.,!S]:EiN 1::, !HF.:. LENI]TH ,::ii'-,l F'EE:T) OF 'THE TRENi:::H ')17 E:,F:'FiII'..F"~E:LE'. THE DE?TH :'~F Ft TREI,'4E:H 0~':: PIT I:5 -i'HE E:,I[':';"FFiNC:E E_F'TH[EEN THE E, URFFIZ:E OF '!".FIE I],I:.'?.OUI,',!E:, FIND THE ~:,UI lUll 'ZIP' THE:. E:"::E:R',,,'RTION ,'.I;N PEET::,. THERE-.,.':::,-' NO '-E;ET I,.t:[DTH FOR TO,..EL_~-' E .... THE: 6RF!',,,'L'-L DE:PTH -':' "',-,'" .L, THE H?.N_T,h!I_t?! [::,EPTH OF '3F:'R',,'EL. E~ETI.,.IEEN THE OIJTF'F!L.L. RNE? THE ,<.: ": TT ': H OF THE EXE:RVFIT i' ON ,' ',.:.¥ FEE:T ::,. PE~:H,Z.T 'F.F'F:t.:[Z:Fff..T HFr_:; THE F:E:F.';PON':-.q:Ef:[LZT'¢ -FO .[J...7 ....... : ....... h.u,F,.:...'] ~T_N::, 0F' FIN'-/ HELL:.:: Fir_':,._~'FIE:ENT TO TH::E: FN._,F,....,. ........ THE pFF:F- OF PF":"",EF!'"F":; I"~-IF~T THE HELL H:[LI. ..... ~..F:.. E. E',FIE:k:I,.:: ]: LL Z NG OF Fli,',?:-' :-?'/:5'FEH l.,.l ]: ?'HL-II..IT F :[ I'.,!FJ..L _T N'-:.';F'ECT .T. ON FtNC, ,4 F, ..t .................. DEF'Fa.,R"f'HEI,.,IT !,.!): LL.I:':,E .......... ': E "F' - T TO F'F:C~'_:.;EE:UT Z ON. H!NIHU!"! DISTRNCE BET[qEEN f:~ HELL. ,~N[::, FIN'.? Of",F-S;ZTE SEHFIGE DISPOSFIL S'¢STEM IS :~C~8 FEET FOR F! F'RZ'¢RTE HELL. OF;: :{5~3 TO 288 FEET FR:OH R PUE=L. IC HELL DEPEh!t, ING UPON THE T'¢PE OF PI. JB[..ZC HELL HZN!HLih! C'IS'TRNCE FROH R PR!',,,'RTE HELL. 'f'O R PRIVR"I'E E;EHER L. ZNE Z2; 25 FEET FIND TO R COI,'!HUNIT"r' E;E:HEF: L.:[NE !~; 75 PEET. OTHEP. REQUIF~E?!EI",FF~; Hi::t'¢ FIPPL.Y. SF'ECZFZC:FtTION2; FIND CONSTRUCTION [:,ZBGRF:i!"!:~¢ PRE RVRILRBLE TO :INSURE PROPER INSTRL. LRTION. I C['::F.'.T..T.F'¢ 'THF!T J.: .T. FIH FRHIL. ZRR ['.!ZTH THE REQU.T. REHENT2'; F'OF: ON'-S:[TE ?:;EHEF:S RND [4ELL:~; ,ciE; ':.TET FORTH B"r' THE: HUNIC:ZPFiLZT'¢ OF RNCHC~E:FfGE. 2: ]: H:[LL. INS'TFILL THE S'¢S'FEI'! IN RCC:ORDRNCE H:[TH THE COB, ES. FX:: I UIqDER':-":I"FIN[::, THRT THE ON-SITE 5E!,].E,:;: S'./'_-:'TEI,,1 h'l,'::l'-,-' RE6!UIF'.E ENLRRGEHEJ',F[' IF THE: RES;I'£)ENCE If--: F:EHODEL. ED TO '_(NC:LLIC, E MORE THF:IN 4. DEDF:'.OOP1.E.. J,,'., ^./' FJFPL._TC:FJN/:' .:rEFF ~,, -' MUNICIPALITY OF ANCHORAGE ¢ 'I'MENT OF HEALTH AND ENVl RONMENTAL PROTECTION [] PERCOLATION TEST SOILS LOG - PERCOLATION TEST -[4Et= F ~¢/'~.su~-¢ DATE FERFORMEO~ PERFORMED FOR: LEGA'DESOR'PT'O": LOT "-/, 9LO6~2-.. So~ IT ' SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? 13 14 15 16 17 18 19 20- COMMENTS PERFORMED BY: IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ISC) V; s ¢ II"~(minutes/inch) T~,~..~..~ ~ 'l,~f~"~-~ RUN BETWEEN FT AND -- FT 72-008 (6/79) APPLI ,NT FILLS OUT UPPER HA~ ONLY Type of sidence e Family E~ Multiple Family NO of Bedrooms [] Other Water Sup y ual (~ ~ !' ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. Community ·-~'~ For wells drilled prior to that date, give well deplh (attach log if available). [] Public Utility When Connected to Public Utility: [~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Date Date Date Date Inspector Inspector Field Notes: z',s RECEIVED ~ ~PPROVED BEDROOM8 'OONDITION8 OF APPROVAL ( ) DISAPPROVED Soils Rating Date ~wer Installed Well To Absorption Area [~ Well Log Received July 8, 1983 Jeff Wesley Box 40205 Portland~ Oregon 9 7240 Subject: Lot 7, Block 2, Summit Estates Approval for the individual sewer arid water facilities cannot be granted until the following items have been completed: ° The top of the well casing should be sealed so that it is water tight. o Exposed electrical wires to ghe ~¢ell head are in violation of the ~Iunicipality of Anchorage codes and ~nnst be encased in conduit. Please notify this Department for a reinspection when the noted discrepancies have been corrected° if there are arty further questions, please call this office at 264-4720. Sincerely, Robert C. Pratt ~, · ~ · ~ Specialist RP21/ej/E2 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval / / 3 Parcel I.D. 015-072-12 Legal description SUMMIT ESTATES BLK 2 LT 7 Expiration Date: 0 Site address 5522 E 97TH AVE Anchorage AK 99507 Current property owner(s) CIM REO 2021-NR1 LLC The On-site system(s) is/are approved for bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: septic tank to be replaced under permit OSP231114 by July 15, 2023 By: _ITA/v� /2 &O -cam P Original Certificate Date: 6/9/2023 615/zoz 3 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) islare in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval June 2022 Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 015-072-12 Complete legal description SUMMIT ESTATES BLK 2 LT 7 Location (site address) 5522 E 97TH AVE ANCHORAGE AK 99507 Current property owner(s) O'CONNELL SEAN & THERESA Day phone 907-346-0104 2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS 3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑©-- Plastic ❑ Concrete ❑ Fiberglass Age New - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑© Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: 0 Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ Date of Payment COSA# OSC Z 3 1/(, 5— Waiver Fee $ Date of Payment Waiver # COSA Application June 2022 COSA Checklist Legal Description: Lot 7, Block 2, Summit Estates Parcel ID: 015-072-12000 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Unknown Total depth Unknown ft Cased to Unknown ft 0 Sanitary seal is functioning correctly ❑■ Wires are properly protected Casing height (above ground) 12 in. Date of flow test for COSA 5.17.23 Static water level at beginning of test 59 ft. Comments See attached water sample testing results. B. TANK DATA Measured operating fluid level in septic tank New Date of pumping N/A ❑ Required maintenance completed, if AWWTS Comments: New Tank installed under Permit OSP231114 D. ABSORPTION FIELD DATA Which system tested (date installed) 1982 ❑■ ALL standpipes present per record drawing Total measured depth from grade 13.5' ft (max) Measured depth to pipe invert from grade 4'+ ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 44" OF Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced 2000+ gallons 5.23.23 date Any rejuvenation treatment (past 12 months) NO If yes, enter date Well production at time of test 2.5 gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑■ No ❑■ Coliform bacteria is Negative Nitrate 4.14 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L X Arsenic less than MRL (ND) Collected by Gabriel Thomas Date 5.24.23 C.=STATION❑ R Age of lift station . Lift station material Comments: ance completed Adequacy test date 5.24.23 Results 0 Pass Fluid depth prior to test 32 in Water added 460 gal New fluid depth 43 in Elapsed time 555 min Final fluid depth 29.5 in Absorption rate 450+ gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 60 in Effective depth used 29 in Effective depth remaining 31 in Comments/Deficiencies: The effective depth used includes the systems recorded effective depth, below the measured bottom of the Monitoring Tube (16.5"). This 16.5' of additional effective depth was also applied to all applicable field testing fluid measurements, for an example: Fluid depth prior to test: 15.5"+16.5'=32". COSA Checklist June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' g Yes Community Sewer Manhole/Cleanout > 100' DYes if No ft ❑■ Yes if No ft Neighboring Tank > 100' Foil Yes if No ft Private Sewer/Septic Line > 25' Q■ Yes if No ft Absorption Field on Lot > 100' [j] Yes if No ft Holding Tank > 100' ❑■ Yes if No ft Neighboring Absorption Fields > 100' Yes if No ft Water Main > 10'■❑ Animal Containment > 50' 0■ Yes if No ft ❑i Yes if No ft ❑■ Yes if No ft Water Service Line > 10' Q Yes if No Manure/Animal Excreta Storage > 100' If tank or field is under driveway comment below Community Sewer Main > 75' ❑■ Yes if No ft r■ Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' g Yes if No ft Surface Water > 100' ❑■ Yes if No ft Tank to Property Line > 5' F■ Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' ❑■ Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10'■❑ Yes if No ft Community Wells > 200' ❑■ Yes if No ft Water Service Line > 10' Q Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS New 1000 gallon septic tank installed - Cross reference permit# OSP231114 G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone 907.317.8970 Engineer's Printed Name Gabriel K. Thomas, PE Date 08.03.23 OF A/_, 0kI`o �C���, � ........... Gabriel Thomas - Ir,1i lF9FONo. 810N 0 1►�_ OFESS COSA Checklist June 2022