Loading...
HomeMy WebLinkAboutSUMMIT ESTATES BLK 2 LT 10 SUMMIT ESTATES BLOCK 2 LOT 10 #015-072-09 Permit Number:OSP251404 Tax Code Number:01507209000 Work Type:Septic Upgrade Effective Date: Design Engineer: Site Legal Address:SUMMIT ESTATES BLK 2 LT 10 G:2437 Owner:GILLIS JOAN M Site Mailing Address:5481 E 98TH AVE, Anchorage Lot Size in Sq Ft:18000 Total Bedrooms:4 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 11/10/2025 11/10/2026 HUBER ENTERPRISE Expiration Date: þ þ ¨¨¨¨ Issued To: Issued By: Date: Date: 11/10/2025 11/10/2025 HUBER ENTERPRISE Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE INSOMMEM Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 01507209000 Property owner(s) Gillis, Joan M Day phone Mailing address 5481 E. 98th Avenue, Anchorage, AK 99507 Site address 5481 E. 98th Avenue, Anchorage, AK 99507 Legal description Summit Estates BLK2 Lot10 Number of Bedrooms 4 Engineering Firm Huber Enterprise AK Building Permit Number APPLICATION IS FOR: (® all that apply) Disposal Field 0 El Septic Tank Holding Tank Privy Well Water Storage Not Applicable ❑ APPLICATION IS AN: Initial ❑ Upgrade Q Renewal ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Separation distance from well to Septic Tank Permit/Rush Fees: I sq Date of Payment: /�L(117G17-' Permit No. Osfz/*# May 2025 Distance:- Waiver Fees: 9 Oso Date of Payment: f X11304-5 Waiver No. Q5112_51 G�f(n Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251404, Isatou Njie, 11/10/25 Summit Estates BLK 2 LOT 10 SepƟc Tank and Drainfield Design Project NarraƟve/DescripƟon: Summit Estates Block 2 Lot 10, beƩer known as 5481 E. 98th Avenue, is an exisƟng 4 bedroom residenƟal property. According to available as-built informa Ɵon, the residence has an exisƟng sepƟc system that should consists of two (2) sepƟc tanks connected in series to a secƟon of Deep Trench absorpƟon field. The original system was installed someƟme prior to 1977, because records indicate it was upgraded in 1977. The 1977 upgrade consisted of adding an addi Ɵonal sepƟc tank and a new trench drainfield. This does not match current observaƟons in the field or the recent asbuilt survey. It appears only one tank is present. If differing condiƟons are discovered during construcƟon, it will be noted on the asbuilt drawings. However, the enƟre system is in need of replacement and will be upgraded to current standards. Based on the new asbuilt survey, the exisƟng sepƟc tank is located within the 100-foot separaƟon radius from the private water well on the property. The ExisƟng Well is located near the SE corner of the residence, approximately 75 horizontal feet from the exisƟng SepƟc Tank. ShiŌing the locaƟon of the new sepƟc is part of the design plans to increase the separa Ɵon distance. The new tank will be located approximately 86 feet from the exisƟng well, and therefore a waiver will need to be approved for construcƟon. Well Radii are shown on the design plans. A porƟon of the exisƟng drainfield is located outside of the property lines and within the ROW of E. 97th Avenue. This will be addressed in the re-design. The 100-foot separaƟon radius from the adjacent property’s well is shown on the design plans. There is only a narrow area available for the construcƟon of the new drainfield. See design drawings. A soil invesƟgaƟon was conducted on site on September 21,2025. A Single test hole was advanced and a percolaƟon test was performed. The Test hole was excavated to a depth of 17 feet and indicated +/- 6 inches of Organics/top soil above GW soils to a depth of 17 feet. No water table or bedrock was observed during the soil test. The PercolaƟon rate was determined to be 2 minutes/inch. See included Soils Log – Percola Ɵon Test Report by Mike N Anderson dated 9/31/2025. Design CalculaƟons Flow Rate: 4 Bedroom Main Residence at 150GPD/Bedroom - Design Flow = 4 bedroom X 150 GPD/bedroom = 600 GPD SepƟc Tank Size: Minimum Tank Size shall be 1000 gallons plus 250 gallons for each bedroom over 3 per AMC 15.65.205 - 1000 + (250) = 1250 gallons PercolaƟon Rate: Soil TesƟng indicated a percolaƟon rate of 2 min/inch. ApplicaƟon Rate: - Per AMC 15.65.210 Table 2 for ConvenƟonal Subsurface Disposal Fields, The ApplicaƟon Rate for soils with percolaƟon rates of 1-5 Minutes/inch shall be 1.2 gallons/day/square foot. - Design ApplicaƟon Rate: 1.2 gallon/day/square foot Drainfield Area: - (600 gallons/day) / (1.2 gallon/day/square foot) = 500 Square Feet Drainfield Design: Deep Trench 1. The EffecƟve AbsorpƟon area of deep trenches is calculated as the area of the sidewalls below the invert of the distribuƟon pipe. - Required EffecƟve AbsorpƟon Area = Length of Trench x EffecƟve Depth x 2 2. An EffecƟve Depth of 7 feet will be uƟlized for this site. 3. Minimum Trench Length: L = 500/7/2 = 35.71 = 36 feet Variance Request: Due to site constraints and available construcƟon space, a variance will need to be approved for the installaƟon of the new SepƟc Tank. The new sepƟc tank will be located 85 linear feet from the onsite water well. This is within the code mandated 100 foot separaƟon distance. There is no available area on the property for construcƟon of a tank that would be outside the 100 foot radius. However, the proposed tank is further away from the well than the exisƟng tank – improving the separaƟon distance. Also, water analysis indicates that current levels of Nitrates/Nitrites are below detectable levels. Replacing a failing tank with a new tank will help ensure this remains true. Furthermore, the proposed tank locaƟon is down grade from the well locaƟon. Any potenƟal overflow situaƟon would not approach the well locaƟon. Also due to site constraints and available construcƟon space, the longitudinal length of the proposed drainfield will not be aligned directly parallel to the exisƟng grade contours. The onsite well radius and the well radius of the adjacent property create a narrow strip of land that is available for drainfield construcƟon. If the drainfield were rotated parallel to the contour of the land, it would encroach into the protecƟve radius. The proposed drainfield is aligned as parallel to the contour as possible. The soil test hole indicated a consistent layer of GW soils to a depth of 17 feet. The deepest porƟon of the proposed drainfield will be approximately 5.5 feet above the boƩom of the test hole. A confirmaƟon test hole will be advanced in this area prior to installaƟon to ensure necessary 6 foot separaƟon from any potenƟal confining layer. Should you have any quesƟons or require any addiƟonal informaƟon, please do not hesitate to contact me. Sincerely, Logan M. Huber P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251404, Isatou Njie, 11/10/25 ys Municipality of Anchorage t )rpatnxnt r•. P.O. Box 196650 0 4700 Elmore Road Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997 http://www.muni.org/Onsite Development Services iii On -Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV251046 COSA#: Permit#:OSP251404 PID#: 015-072-09 Legal Description: SUMMIT ESTATES BILK 2 LT 10 Engineer: HUBER ENTERPRISE Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the private well has been approved. The approved separation distance is 86.0 feet. This waiver approval applies to the proposed septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Your request for a waiver allowing the disposal field orientation, where the long axis does not follow the contours of the original ground, has been approved. This waiver applies only to the proposed disposal field. Any future upgrades to the on-site wastewater disposal system will require new approval from this department. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: 11/10/2025 Approved by: --- Name of Reviewer ............................................................................... **** VARIAN C E/WAIVER REVIEW **** Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251404, Isatou Njie, 11/10/25 Feet 0 10 20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251404, Isatou Njie, 11/10/25 Development Services Department Building Safety Division in -site Water x, Wastewater Program 4700 gragaw Street P.D. Box 196650 Mark Begich Anchorage, AK 99519-6650 Mayor •Ww..:rion i.orq/r"nsit� (907)343-,'904 Pump Installation Log Well Drilling Permit Number: SW_ Date of Issue: Parcel Identification Number: Legal Description Property Owner Name & Address: $ U /71 !rl rT F s TA 7-45S i--� v a 2--i0 gwl �d£ Pump Installation Date: A Pump Intake Depth Below Top of Well Casing: V3 feet Pump Manufacturer's Name: ZCRA'�tx)l Pump Model: 917PVMSOs; j31 Pump Size Ila hp Pitless Adapter Burial Depth: /0 feet Pitless Adapter Manufacturer's Name: X14 Pitless Adapter Installer: Well Disinfected Upon Completion? 91 Yes ❑ No Method of Disinfectio : Cr P 7 Comments: Pump Installer Name: A1,4YR.�U tO xA)) S Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. oGRE- -dR ANCHORAGE AREA BOlt',AGH Department of Environmental Quality 3330 C Street Anchorage, Alaska gg§03 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME 0 MAILING ADDRESS .J~ O~ S~" ~ PHONE LOCAT, ON LEGAL DESCR,PT,ON SEPTIC TANK: FROM WELL ~O ~ MANUFACTURER ~[ MATERIAL COMPARTMENTS INSIDE LENGTH INSIDE WIDTH. LIQUID DEPTH LIQUID CAPACITY ',-~:~) GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL //~O I ~-D/~ ~)-- J TOTAL LENGTH FOUNDATION .NEAREST LOT LINE OF LINES NUMBER OF LINES : DISTANCE BETWEEN LINES ~/~ TRENCH WIDTH~¢IN. TOTAL EFFECTIVE ABSORPTION AREA%¢g ~ ;~ SQ. FT. LENGTH OF EACH LINE ~ / ~/~/~& ~ / DEPTH OF FILTER / DEPTH: TOP OF TILE TO FINISH GRADE ~ MATERIAL BENEATH TILE ~ ~ABOVE TILE ~ IN. WELL: TYPE ~A/~?J M/~'/~-/ CONSTRUCTION DEPTH BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION LOT LINE__ SEWER LINE TANK SYSTEM CESSPOOL , OTHER SOURCES APPROVED __ DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: INSTALLED By: ~//~ ~'~-, / SEWER LINE DEPTH: o ~)z LOT SLOPE: REMARKS: Form EQ-032 DIAGRAM OF SYSTEM ..SC, D, G.A.A.B. J. US~ No. Statio°n:~ter Open end~r~); So'eon ( ); Perforated ( ). Describe screen or perforations . Well pumping test at /./~ ~ per (hour)(~u~e~ .~/~ feet-0~ dra~o~ from st~ti~ level ~epth ~ feet from ~round surface and hardness. D to ~inish ~f well (chsok . Wo~i I..o6 ~-~e dst~il~'bf ~rm~tions ~e~etrmted; size of m~tsrial, oo~°~, to to to to t~ to j~U.k!!~lmAI lTV I~1: ANCHOI~A(~I~ DEPT. OF HEALTH & ENVIRONMENTAL pROTECTION 'A~B '1.. 9 'Lqs.B .- RECEIVED to to to DEPFII;-!'rf'IENT OF HEFII..'f'H bN[:' EN;/I RONMENTFII. PRO"IECT I ON F~PPL. ICbNt' CLYDE ~TERL. ZNG. { BOX 567 ~TERL. ING LOCATION 90 BIRCH LEaRL LOT :La BLK a SL/MMIT~E~'ra'rES LOT SIZE NONE t627.00 SQIJFIRE FEET TYPE OF SOIL bBSORBTION ~-TIE. I~I I:S: PIT MAXIMIJN HUMBER OF B~DROOMS = 4 SOIL RATING THE REQUIRED SIZE OF THE SOIL. HB_,uRPIluN _Y, 1EII THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF EbOH SIDE FOR FI SEEPFIGE F'IT. THE DEPTH OF B TREN(,.H OR PIT IS THE DISTFINCE BETWEEN THE StJRFBCE OF THE CtROUND FIND THE BOTTOM OF THE EXCFtVFITION (IN FEET)· THE GRFIVEL DEPTH IS THE MINIMUM DEPTH OF GRFIVEL BETWEEN THE OUTFFILL PIPE Rt',ID ]'HE BOTTOM OF THE EY, CRVFITION (IN FISET), IHI_, BACKFILLING OF FtNY SYSTEI¥1 WITHOUT FINFIL INSPECTION FIN[:' BPPROVFIL B'¢" ':: DEF'ARTMENT NIL.L BE E;IJB,$EC'i" TO PRCSEC.TION. MINIMUI4 DISTFINCE BETWEEN FI WELL FIND RNY ON-~ITE SEWAGE DISPOSF~L SYSTEM IS t00 FEET FOR FI PRIVFITE HELL OR 2C~0 FEET FOR FI PUBLIC WELL, SPECIFICFITIONS RND CON:E;TRUC'TION DIFIGRFIFI$ FIRE ¢4VFIILFIBLE TO INSURE PROPER I Ns'rFILLBT I ON. I CERTIFY THFIT IL: I RI,i FFIMILIFIR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS EtS SET FORTN B9 TWE 1,1UNIOIP~L~'FY OF ~NCHOR~GE. ~ I WIlL INS'T'~tLL THE SYSTEM IN ~OCORD~NCE WITH THE CODES. ~: I UNI)~RST~D THBT THE ON-SIT~ SEWER SY~TEW M~Y REQUIRE ENL. FIRGEMENT IF THE RESIDENCE IS REWODEL. ED TO INCLUDE MORE THSN 4 BEDROOWS. APPLICANT CI.~DE STERLING. CONSULTING GEOLOGIST SOIY~.S LOG Per£ormed £o~ ~"~ ~'~ &~, ~, ~'~.. ~ ~epth (~eet). Soil Description' -16- -18- -20- Total Depth 14 Was gro~Lndwater encountered Depth to bedrock ~ £eet in determined Resp~c-~£ully submilted, Gary ~o Player Consulting Geologist ' ~. ' / MUNICIPALITY OF ANCHORAGE' '~ '~-"" ' r, ~ ~"~,: ' ~ ',=~~.: ,DEIARTMENT'Or HEALTH ANDtINVI.RONMENIAL::,-ROIEC=TIO ~~¥~ :' ' 825 L Street, Anchorage, Alaska 99501 iik~[~[~'~-~l [ ' C 279-2511, ext. 224, 225 · ' :::i~ppp.. ,~. ~ Date ReceiveS: March :25' 1977 Time ~ and Inspection: Time ls% Inspection: Date ~~ Date Inspector ~ ~D~ Inspector REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES Lending Institution Request: Lomas and Nettleton Company Mailing Address: 4449 Business Park Boulevard Phone: 274-7661- 2. Property Owner: Mr/Mrs Ste~ling~_~ ~ ~.~ Phone: 344-3004 Mailing Address; NHN East 90th Avenue ~:~ ~ 3. Legal DescripEion: Lot 10 Block 2 Summit Estates Subdivision SingLe Family Residence: (x) Multiple F~nily Residence: ( ) Number of Bedrooms: N~kmber of Bedrooms: 4 5. Well Data: Type Individual Depth 87' Well Log Filed ( ) Construction Bacterial Analysis Sewage Disposal System: Permit ~ Septic Tank Size Absorption Area On-site system (x) Public Utility Installed Installer Manufacturer Soils Rate Material ~ ) Distances: Well to Septic Tank to Sewer Lines Nearest Lot Absorption Area to Nearest Lot Line Line to Absorption Area Page-~.wo . · ~ ~ [~i~, ~ ~?'~ .....: I, ~ ~' ,- -', ' Department%, of~~ H~hlth' ~and Environmental Protection~ : ~ ~ R~.'quest- for Approval of Ihdividual~ Sewer and Water Facilities Legal Description: Lot 10 Block 2 Summit Estates Subdivision Co~e~%s: Approv ed: Department/~/~ ~7' . Worksheet:~ ~ ~ ~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L Street, Anchorage, Alaska 99501 279-2511, ext. 224, 225 REQUEST FOR APPROVAL OF INDIVlDUALSEWERand WATER FACILITIES MUNICIPALITy OF ~. DEp;: 0"' ANCHop,~,'.,- .... ~cNTAL PR "~ OTEChoN RECEIVED 1. Type of Inspection: VA X FHA CONV_ Mailing Address:_ /L ~/k . Ma,l,ng Address: ~ L/,.~ ~ ~/'/~. ~ ~f/~.~..,~ ~ ~ Day Phone: Name of Lending Institution: ~ ~'~ ¢ %~*~'(, ~. D/~.y Phone:,-./~ ~-J~)/ Location: 7. Type of Facility to be Inspected: No. Bdrms. .~ 8. Water Supply Type of Supply: Public Utility Individual If Individual, depth of well Sewage Disposal System Type of System: If Individual, number of dwellings presently served Public Utility. Individual (on-site). If Individual, date of installation 72-OO3(3/76) April 25, 1977 Lomas and Nettleton Company 4449 Business Park Boulevard Anchorage, Alaska 99503 Subject: Lot 10 Block 2 Summit Estates Subdivision A percolation test was perfomed on the subject property and the test showed that the system did need upgrading. I ran a file search and could not find any information on the existing system. In order for this department to draw up an upgrade for the existing on-site sewer system a soil test must be performed and brought into this office. If there are any further questions, please contact this office at 279-2511, extension 224 Or 225. olncerely, william M. Dixson Principal Environmental Code officer ~,{D/1 J h cc: Mr. and 5~s. Sterling Star Route A Box 77 99507 April 6~ 1977 Krenik Realters 605 A Street Anchorage, Alaska 99501 Subject: Lot 10 Block 2 Suimmit Estates Subdivision Before sewer andwwater approval can be granted by this department verification of the septic tank must be provided by exposing thesseptic tank manhole. Also, the septic tank must be pumped for maintenance purposes° A percolation test on the absorption area must be performed as set forth in the attached instruction sheet. If there are any further questions, please contact this office at 279-2511, extension2224 or 225. Sincerely, Willi~ M. Dixson Environmental Principal Control Officer WMD/lj h attac~aent Isaacs Pumping Service 6218 Quinhagak Street Anchorage„ AK 99507 Phone # 907-563-3300 isaacspumping@gmail.com Fax # 907-562-5473 Sold To Gillis,Joanl 5481 E 98th Anchorage, Alaska 995}b 0'7 Sales Receipt Date Sale No. 6/3/2020 9381 Check No. Payment Method Project 6/2/2020 Description Qty Rate Amount Pumped Septic System 210.00 210.00 Total $210.00