HomeMy WebLinkAboutSUMMIT ESTATES BLK 2 LT 16Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM DISTANCE / ZS-' NUM EROF FROM WELL MANUFACTURER MATERIALcg-~C` ]~/$~'~COMPARTMENTS INSIDE LENGTH INSIDE WIDTH . LIQUID DEPTH SEEPAGE PIT: ~A",~ //}t2 NUMBER OF PITS J DIAMETER OR WIDTH LINING MATERI,~,I'~'/~YLC, ~:~)('/~RIB SIZE: DIAMETER BUILDING FOUNDATION NEAREST LOT LINE .LIQUID CAPACITY LENGTH DEPTH DEPTH (.~ DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) GALLONS. SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE ~/~m; BUILDING FOUNDATION __ //~.. ~]4/]/C CONSTRUCTION NEAREST LOT LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED DEPTH DISTANCE FROM: NEAREST SEPTIC/ ~-~ /, SEEPAGE SEWER LINE TANK / ~' / SYSTEM .// ~'~ ' DISTANCES: INSTALLED BY: ~ Y/ fl/}~'~ ~ PIPE MATERIAL: LOT SLOPE: Form No, EQ-031 DIAGRAM Of SYSTEM ~/ Greater ANChORAge AREA Borough DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 J~,~ , SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT NAME OFAPPLICANT ~~__~ MAILING ADDRESS INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED SEEPAGE Pit ~ DRAIN FIELD OTHER TO BE INSTALLED BY FINAL INSPECTION: 24 HOUR NOT~CE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEEPAGE AREA SIZE TYPE DIAGRAM Of !SYSTEM SEPTIC TANK SIZE TYPE MINIMUM DI~*TANCE~, REOUIREMENT~ FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEPTIC TAI~K TO SEEPAGE PIT WALL - SEPTIC TANK .,seePAge Pit TO NEAREST LOT LINE. ~eLL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, SEEPAGE PIT TO RIVER· LAKE. STREAM. , DRAIN FIELD ALSO CONSIDER AREA WELLS, · SEEPAGE Pit CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP Of EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAge PIT GRAVEl. BACKFI~ ' CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION, [ CERTIFY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. FORM NO* EQ-016 GRE/,. ,~R ANCHORAGE AREA BOR. "IGH Department of Environmental (~uality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK,: DISTANCE NUMBER OF ~.o~ w~ ~A~AC*U~ ~ ~n~ ~,~,~ ~, ~/~/~ co~,~,~ / INSIDE LENGTH ~' b' INSIDE WIDTH LIQUID CAPACITY GALLONS. NUMBER OF PITS / DIAMETER OR WIDTH LENGTH DEPTH ~ LINING MATERIAL~C ~C~CRiB SIZE: DIAMETER__DEPTH~/ DISTANCE FROM: WELL TOTAL EFFECTIVE BUILDING FOUNDATION NEAREST LOT LINE~ ABSORPTION AREA (WALL AREA) SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE *~ f~ ~'~ CONSTRUCTION DEPTH BUILDING NEAREST NEAREST SEPTIC FOUNDATION __ LOT LINE SEWER LINE TANK CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCE FROM: SEEPAGE SYSTEM INSTALLED BY: PiPE MATERIAL: LOT SLOPE: Form No. LQ-031 DIAGRAM OF SYSTEM GrEATEr ANCHORAGe ArEA BOrOUgh ~,~EWAGE DISPOS~AL SYSTEM -- APPLICATION AND PERMIT DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4361~' PERMIT NO INSTALLATION OF: SePTiC TANK ~ ~ SEEPAGE PIT ,~/~ . OTHER FINANCED THROUGH ~ TO BE INSTALLED BY ~/~ ' NOTE, THIS PERm ~ VALID WITHOUT SOIL T~ST ~y~ i WITHO~. FINAL INSPECTION BY TN :INAL INSPECTION: 24 HOUR NOTICE REQ IRED. BACKFILLING OF AN'~ S¥STE~V DEPARTMENT OF ENVIRONMENTAL QUALIT THORITY WILL BESUBJEC'I TO PROI ECUTI ~EPTIC TANK SIZE . TYPE EEPAGE AREA SI .~E / TYPE OF SYSTEM FOUNDATION TO SEPTIC TANK SEEPAGE PIT WALL /~ SEEPA DRAIN F~ELD , ALSO'ICONSIDER AREA WESL~ CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit FITTED WITH AIRTIGHT REMOVABLE CAPS. Gl~AVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDJ~'~G INSTALLATION. I CERTIFY THAT ]AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-6 D~THAT THE ABOVE OATE APPLICANT'~ $ISNATURE DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE DISTRICT OFFICE 3601 C STREET, SUITE 322 ANCHORAGE, ALASKA 99503 / / WALTER J. HICKEL, GOVERNOR (907) 563-6775 RECEIVED ~,. ~ ~1;:~, April 2, 1992 APR 6 199~ . Anchorage, Alaska 99508 ~ ~- ~ .. ~:. ~ Subiect: koi ~, Block 2, ~ummit Estatos, Anchorage, A~aska, Wastowator ~ Disposal Systom, ADfiG ~rojoct ~umber ¢22~-D~-0~8, ~oviow Dear Mr. Pearson: This is in response to your submittal, received in this office on February 28, 1992, which included a site diagram of the proposed holding tank and several reasons why a conventional wastewater disposal system should not installed on the above-referenced property. I have reviewed the submitted information, this office's file on Summit Estates, and pertinent design and wastewater treatment criteria. Based on this review, I have the following comments. Based on the intended use of the facility and your assumption of the subsurface soil conditions, as detailed in the submitted data, it appears that a conventional wastewater disposal system would degrade the aquifer that is currently being used as a source for several private and public water systems. The degradation could result in contamination above the maximum contaminant concentration levels for the parameters noted in the State Drinking Water Regulations. Thus, the rationale for the use of the proposed holding tank is accepted by this Department. Therefore, subject to the following requirements, the construction plans are approved for the concerns of this Department, in accordance with the provisions of 18 AAC 72, Wastewater Disposal Regulations. The installation of the holding tank will be monitored by a Professional Engineer (P.E.). Complete as-built drawings of the hold tank will need to be submitted to this office under the stamp of a P.E. The submitted as-built drawings will need to verify the depth of burial and the location of the high-level alarm. Mark Pearson 2 April 2, 1992 3. The attached forms will need to be completed and returned with the as-built drawings. 4. Calculations that were used to size the holding tank will need to be submitted to this office under the stamp of a P.E. 5. Specifications on the high-level alarm system will need to be submitted to this office. 6. A copy of your February 23, 1992 letter will need to be submitted to this office under your stamp as a P.E. This approval does not imply the granting of additional authorizations, nor obligate any state, federal, or local regulatory body to grant required authorizations. Thank you for your cooperation with this Department. If you have any questions, please do not hesitate to contact me. Sincerely, Keven K. Kleweno District Engineer KKK/cf' Enclosures: As Stated cc: John Smith, MOA/DHHS, w/o Enc./ ':= APPLIC ?T FILLS OUT UPPER HAL ,ONLY" j~; oped~ ~Ow~er * ,*. , Phone Buyer Address Zip Code Lending Institution ~, ~5~ ~ ~ ~D/ ~ ~O~J Phone Address ~ ~7 ~ ~~ 5~ Zip Code Realty Co. & A~nt Phone Address Zip Code Type of Resi~noe ~Single Family ~ Multiple Family No. of Bedroo~ ~ Other Water Supply ~lndividual A~ACH WELL LOG. A w~l log is required for all wells drilled since June 1975. ~ Community For wells drilled prior to lhat date, give well depth (attach log Jf available); ~ Public Utility Sewer Disposal ~lndividual Year Indiv~ual Installed: ~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATEd. Time Time Time Time Inspector Inspector Inspector Inspector Field Notes: ( ~ ) APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAP~OVED ( ) CONDITIONAL APPROVAL* Soils Raling Date ~wer Inalalled Well To Absorplion Area J 72-023(3182) August 10, 1982 D. [~ichael Hellings & SP~ Box B5 Anchorage, AK 99507 Susan Russell ~ub]ect. Lot 16 Block 2 Summit Estates Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: Exposed electrical wires to the well head are in violation of the ~unicipality of Anchorage codes and must be encased in conduit. °~ ~[~Te water analysis report needs to be submitted to this office from the Chem Lab, '_~63~ B Street, for our review. The septic tank pumped v;ith a receipt submitted to -this department. ur ( cast be installed to tank and/or leaching area. ~ An adequacy test needs to be performed on the existing leaching area. This test will determine if the system is pd.equate according to ~]ational Standards. A listing of rlvate firms performing the test is enclosed. This report ~eeds to be submitted to this office for our review. The.standpipe to the sewer system need caps on them. Please notify this Department for a reinspection when the noted discrepancies have been corrected. If there are any further questions, please call this office at 264-4720. Sincerely, Cory Enclosure ALASKA LAND DEVELOPMENT SERVICE5 Engineen . Sun, eyon - Plannen 4546 BUSINESS PARK BOULEVARD ANCHORAGE, ALASKA 99503 August 24t 1982 PHONE (907) 279~7451 Susan ~ellin~s SRABox 8~ Anchorage~ Alaska 99507 To Whom It May Ref: Adequacy Test on Seepage Pit and Septic System on Lot 16~ Block 2, Summit Subdivision On August 18~ 1952t I started an adequacy test 'on Lot 16~ Block 2, Estates Subdivision for Susan Helllngs3 The property was inspected b~ myself and George Strother on August 16~ 1982. The house on the property is a five bedroom two story single family dwelling. The well is in the front of property and the septic tank and seepage pit are on the back of the lot. There is more than a 100 foot separation between the well and the pit. The well casing is approximately thirteen inches above the surface~ The well seal appears to.be tight and functional. A water sample taken by the Municipality of Anchorage Health Inspector on August 9~ 1982~ is found to be acceptable. A copy of those results is enclosed with this report. The pit was pvmped on August 17~ 1982. On August 18~ 1982 at 10:20 AM~ clear water was run into the pit at the rate of 7.5 g.p.m.~ the maximum flow that would come through the garden hose. This rate was continued untO! the maximum da~ly rate had been pumped into the pit. The ~ater level in the pit was measured from the top of the cleanout pipe. The depth to water level prior to starting was 8.5 feet. Eight hundred §allons of water were pumped ~nto the pit. At the end of the first day of pumping~ the water had risen .55 feet. Twenty-four hours later~ the water level was at 8.45 feet from the top of the stand pipe. Om August 19~ 1982 starting at 1:05 PM another 800 gallons was once again pumped into the pit with the depth monitored at 50 gallon intervals. At the end of this pumping~ the water level was at a depth of 7.55 feet from the top of the stand pipe. On August 20, 1982 at 4:00 PM~ the pit was again measured~ the depth to the water level was at 8.45 feet from the top of the stand pipe. This is within .05 feet of the original water level. In concluslon~ this pit satisfies the requirements of the Munclpallty of Anchorage's adequacy testing procedures. If you have any questions~ please call my office. Sincerely, ALASKA IAND DEVELOPMENT SERVICES~ INC. J~es R. Anderson, P.E. JRA/as ALASKA LAND DEVELOPMENT SERVICES Engineers. Surpeyors - Planners 4546 BUSINESS PARK BOULEVARD ANCHORAGE, ALASKA 99503 PHONE (907) 279-7451 September 20, 1982 Municipality of Anchorage Department of Public Health Pouch 6-650 Anchorage, Alaska 99501 Attention= Cory Willis To Whom It May Concern: MUNICIPALITY OF ANCHORAGE ENVh,,:~!. t. A. ! ;O E ,': I 1982 RECEIVED In reference to the letter I wrote on August 24~ 1982~ regarding the Adequacy Test performed on the septic system on Lot 16~ Block 2 Summitt Subdivision the second paragraph should read~ "The pit and tank were pumped on August 17, 1982. If you have any questions~ please call my office. Sincerely, ALASKA LAND DEVELOPMENT SERVICES~ INC. mes R. Anderson~ P.E. JRA/as L~ I$~ ~JLL J ~ j¼t GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received Time of Inspection Date of Inspection 1. Approval requested by: Mailing Address: 2. Property Owner: REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR Phone:] Phone: Mailing Address: 2'/ /2 .n 5. Type of facility to be inspected 6. Well Data: A. Type ~ C. Construction ~ ~ ~- ~) 7. Sewage Disposal System: No. of bedrooms B. Depth D. Bacterial Analysis A. Installed /?~'~ B. Installer Z~~'~'~ C. Septic Tank: 1. Si~/~O0~. ~,~'~'~'~"~ma~m~-~u~er~-'L~/~'~ D. Seepage Pit: 1. Absorption Area 2. Material (_~-~_, ~ E. Disposal Field: Total length of lines Distances: A. Well to: Septic tank /~-~-- , Absorption area Nearest lot line ~ , Other contamination B. Foundation to septic tank /~-~--- , Sewer Lines __ , Absorption area C. Absorption area to nearest lot line EQ-034 (1174) Page 1 of two pages Page 2 of two pages - Re.st for Approval of Individual S~Wer & Water Facilities' Legal Description Comments Approve' ~.V~_~2~_.~DisapproveX/~ ~ Date :--~/-~.~ Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date £0-034 (1/74) ,, P~ge 2 of two pages - Re .~st for Approval of Individual %~ler & Water Facilities LEgal Description Comments Approved Disapproved~// Date Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environm.e__n~a]_gu_a]±ty~- certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating sati sfactori lY. z~.-~-~ sIGNED ~-~ ~ -~ ~]~''~ ~Date ~ ~ ~/~ ~P EQ-034 (1/74) Municipality of Anchorage D~velopment Services Department'" Building Safety Division On-Site Water and Wastewater Program .. 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak, us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 0/5-- ~'0 '7 ~ - O3 1. GENERAL INFORMATION Complete legal description ~,o t Location (site address or directions) : Current Property owner(s) ' oq: Expiration Date: 16; Block 2; Summit Estates 5641 East 98th St. o. tzo Georgia Benois Day phone Mailing address Lending agency Cal~ f~r'nia Day phone Mailing address 'Real Estate Agent ,q,,~.~nnp Cnn1 I Pr"r~'nt~-9] Vi~YPh°ne 689-6474 . Mailing Address 16635. Centerfield Dr. Eagle River, AK 99577 NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: ' Individual Well :~ Individual Water Storage [] Community Class ~'Well I--I Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [j~ Individual Holding tank [-I Community On-site [-'1 Public Sewer [-'1 I The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska: CertifiCates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates Of Health Authority Approval are valid for 90 days from the date of issue for properties served by a pdvate or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.. ' 4. STATEMENT OF INSPECTION BY 'ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-. site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/6r wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm S & S Engineering Phone 694-2979 Address 17034 N. Eagle River Loop Ste. 204 Eagle River, AK 99577 Engineer's Pdnted Name Robert C. Cowan DSD SIGNATURE L/ Approved for ~' Disapproved. ., Conditional approval for bedrooms.. bedrooms, with the following stipulations: Additional Comments By: Attachments: HAA Checklist Septic System Advisory Well FIowAdvisory . Maintenance Agreements. ,, , Supplemental Engineer's RepOrt Other Original Certificate Date: /-/' '- ,~/- 0 (Rev. 0t/02) LegalDe~c~iption:~L,0'T-.: :_.... . :,/0 ~/.,oc,~ ~,. S~rnr~, ~ A. WELL DATA Well t~,pe~.~iv/t- T ~ If A, B, or C pro'vide'PWSlD # -- Ce Municipality of Anchorage Development Services Department Building Safety Division On-Site Water.& Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 . · www.ci.anchorage.ak.us .,~ (907)'343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST ~--.,~ 7-,~r¢4' iSar~cel ID: : l Well Lo,g (Y/~ Date c6mpleted I ~ (~ .5 Sanitary seal (~/N) Y~-'..J' Wires properly.'protected (~N) Total depth Go +ft. Cased to . . . (~bove ground) , i It' FROM WELL LOG AT INSPECTION Date of ~es Static water l'evel ~J, ft. ~ el i Well production ~ 9;p.m. : - (~, '~ i g.p.m. WATER SAMPLE RESULTS: , i Coliform ! colonies/100 mi. Nitrate .3.5-,3. mg./. ~rsenic: c/.~o~-~i~g;/I. ~-, .. .... DatebfS~i~nple' ,. ,.~ SEPTIC/HoLDING TANK DATA y,,,~....~ ~-+ in. .Other bacteria o colonies/100 mi. '1~.5' & S ENGINEERIN ' Collected ~i Y'iio$4 ,~;!~ ~;v~. Loop Road No: 2u~. ,' F. agle River, Alaska 99577 i Tank Type/Material,, '~' ~-,/3 7"t c- $ 7"p.~ ~. L.. ~ Date installed / O ;;:L 'l ,,5"f o '0 "'gal Tank s~ze~ . . -Number of Compartments Found.ati&r{ i:leanoutl~N) ~. $ Depression over tank (.'Y~ ,,-,' O' High water alarm (Y/t~ "' o ABSORP, TION FIELD DATA ' ' Dateinst~ll~ld'-)o/q'/03- .S0ilrating ~0rft2/b~rm) )-~),- Syste. m~ype! 1 T~,,,,<:// Length' ,'-t 'J~ ~ ft, '. Width , [~ '': 3 ' ft' Gravel brelow pipe '~'- ft. Total depth i ~ ft. Eft. absorption area~ 5'0 ft~ !'Monitoring tube "Y~J' :iDepression over field ~ o Date of adequacy test - "Results (Pass/Fail) For bedroom $ Fluid depth'in absorption field before test . /~~ ....... u · ; Newd~pth':' * in. Elapsed Time: min. ! F~: in,'. Any rejuvenation trea~j~ent~past 12 mo.) (Y/N & type) ! ·::If Yes, give date , r:/ ' ''" .------''""-- LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump o~ Datum ~~"- CyCles tested r SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL'ON'LoT TO: · Septic tank/lift station on lot,/b o '-/-: Absorption field on lot ) O o ~-/- Public sewer main ~J Sewer/septic Service line r ~.5'" ''J-- Manhole_~gm.c~c ,v,,,, High water alarm level at Meets alarm & circuit requirements? On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Water main ¢'~/'~ Wells on adjacent lots ) O 0 ' ~ in. ! Property line b"" -/- ! Water service line Property line J 0 Water Service line 'AbsOrption field Surface water SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: - · 'Y- Building foundation ) o -J--- Water main I 1 0 -)- Surface water 7 o o .~.-/- - Curtain drain ~-~/~ COMMENTS Wells on adjacent lots G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspeciions and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name *J~0~E.4.T ~-. Date - : /~/ Driveway, parking/vehicle storage' HAA Fee $ ~ Date of 'Payment, Receipt Number (Rev. 12/01) Waiver Fee $ Date of Payment Receipt Number SGS Ref.# Client Name Project Name/# Client Sample ID Matrix 1041574001 S & S Engineering Lot 16 Blk 2 Summit Est. Lot ! 6 Blk 2 Summit Est. Drinking Water All DatesFfimes are Alaska Standard Time Printed Date/Time 04/06/2004 15:54 Collected Bate/Time 04/01/2004 14:45 Received Date/Time 04/01/2/004 15:15 Technical Direct~.~~ C. Ede Released~,r-~.--'~/ Sample Remarks: Allowable Prep Analysis Parameter Results PQL Units Method Container ID Limits Date Date Init Metals Department Arsenic 0.00200 U 0.00200 mg/L EP200.9 C (<=0.01) 04/02/04 04/06/04 JM: Waters Department Nitrate-lq 3.52 0.100 mg/L EPA 300.0 B (<---10) 04/01/04 Microbiology Laboratory Total Coliform col/lOOmL SMI8 9222B A {'.<=1) 04/O1104 DK¢ 3O 3O ASPHALT D~IVE~Ay 67.3' N O0°03'W 135.00' (R) 24.0' 0 1'13 30,0' N O0°O~,'W 135.00' (R) 4' C,,~.. FENCE 29.0' ! I D,~le Received Legal Descriptlo, of lhe Locnt{o~ It:stdllet Ha,ne: Ll.'lll{.g Address kli{~l~lllecl by: Icl, ecL' , ,. ,-.; · ';':~'; Ce.ri{fled Installer I-1 ~':~'~i~;' ~{~pi'oved llomeownet keg{stared £ttg{neer ii." ~ATER SUPPLY SYS]EM ., (SECtION,I! IS OP.TION~] ..... ~ource ~ t Water i~ Con~lnmeni (check ill ~at ~pply) I type of Water Supply System §h{d}l Uohimctcla{ ]:acilily ~itl, Esllnlaled Lles{g~ Plow oFless than $00 OPD. Itre-4tment or Water (Check alt that Apply) 1~1 {,lone I-1 ChtorlnatloR [] {qilrallo,i 1~:-' ~{neta! Removal Is *ell wt:c encloied Id ~:ondelt? I~l: i l~ vt, l-l ho I Scpa~tlun UBunce f, om ~c Wall CUln! lo each o[ ~ ioiiowink ~oUtces of ~en~lntfio~: ~epilcd i°idine link On Lol Is~er Lih~ :loscst~epti~loldl,8]:nkon adjacen~Lot , . . IClos.tSewer LIn~s IOO ~ ted{ ,. /OO~ fcei ndic~te ~cp~tlofl die,ncc I'rom i0~lc ~aterJals includJn~ rdeJ ~nk~. piifl~, lubrlcanu sn~ e~er ~V~te[ S~t~ple T~kefl by: (~a~e) S & S ENGINEERING" . ., Sampler Is: tddtes~ Earl6 River, Ala~a I~ ye~t ,-, .' 1"'1 I, Io (¢ a,,,nt/L6le) ..Iv- I['ump Rate ¢l/m'oilable) I Absoq~tio~ ^re~l on Lot Closest Edge of an Absorption Area on Adjacent Lot: / Oc,m ~ Fcc: On Lot rcetl°"l Adjacent Lot Feet ~ knglneer ~ Government orl]c{3! lUate , other - SpeciFy Type ~ Alternate O,slte 0eq0lres e.glnee~ed design) Sniall Commercial Systeni (< 500 GPDI With gstlmaled Dtlly W~le&ater ~low of: " .... Gallons Per Day (GPD} Cti{uhi Used {o I~sllmale bally Wastewater Quahl[ty: I'-1 HI.W sYSl'~M CI ki~pAllzi'0 kxlsl-iHo ~;¥sTI~LI Systenl I,slatled: CI By d heglstei'ed J:,ltglneer I"1 Uy ,~ppro~ed Itom~o~,nel- (attach .copy orapproval letter) Septic Tank: Mateflal:5~f?~/' Manufacturer:~ t"~ ~/" Size (Gallon~J:j -,~O ~ NUmber of Compaftments~:~ Typ~ orsoll ~sotptloi~SyslclH: . ~ l.~eepl'tench ~ shallowTt~nch ' ~ Seepage Pit ~ Mound~ ~ O{hcr,'~peci[y ~r~di.~Slze otblsbl~utlo, go&: ~" 7o 2 '/~" ~lhlc~hcs~pth orbist;i~u[ion RotE: ~' retcolatlo~ ~esl kesults, All,ch Cop~ or kepoth I~c~col~,o.T.s~ ~etrotmcd by: S & S ~GINEERIN .tulOtfl ~roUiid Cover Over: ~cptlc T~n~: ~ Absotplloil At'J:' ~' ~ Sewer hpcs: n.?/'.' · Lid SepJt~llod blslJ,ces ~o~d Sepllc Tan~ or Abso~ptiofi AtcJ, Wl,lch~v~ Is Closed, Io All.'~?by.: Public ~tl~hlg ~aler Sources Wllhln 200 reef: '.~/A" F~l~dle brh~lng Water Sources within 100 %arcs[ ~let Uodles (see 18 AAC 72.020(b)): 1 0 u '~ · Lot Linc: Scp~lloti U[daticc rroni Ohio[ SeWer Lines 1o: ~ubllc bdhkln~ W~[cr Sources: ~/a Prlva~e Sources: ;cp~t~tioh bMd.ce ho.~ boUGht ot blslrlbuUo, kocl~ Io: O~oUud,¥~ter Table: ~ ~ IE3edrock: 07~+ ;ep~u~iloh blsl~ttce I~ro~rl Absotptlod ~te,4 [o Slope exceeding 2S%: ///'~4 :oh~mehts/RecohmmMdatlons certify Ihat the above lnformatio~, and that provided in Sectiolt IV. is correct: igtialOfi~ · //...., / /Typed,T'~ldledNdme SEAL /..~, ~ ¢ ~. '1- ~,, ",.. .... c'-'" ,-- i, '~¢~ _':: ........... .:..., '.~-,,- ITitle, Reg./Cert No., Inst. No. DEC.tta. I~. or · ~tf~l~erea If englneeri.g seal bears pti, f reel name. i" = 40' 'AS-BUILT SITE-pLaN , · ~"  · " 3'.' ~ ' · ..... ~ ~ I ~ ... /. . .-~... ~ ~ - PPROX. LOCATION) , .d~,..;.~..~,,, I I ' ~': ' - ~ I., · N ~,- ~_ I-~ '"' ' ] 5' CEA EAS~.MENT '~ ~ ffi ~ ~ I :~ '. ~.~ ~; 'SCALE. "AS-BUILT (-~ (-~ oo II II SITE-PLAN 0~0~ ~ ~~-- 0 ~00~00~ DIVISION OF ENVIRONMENTAL HEALTH DRINKINGWATER AND WASTEWATER PROGRAM 555 CORDOVA STREET ANCHORAGE, AK 99501 ".'"'~:~ http://www.state.ak.us/dec/deh · ~,~.~'~ ~ Telephone: (907) 269-7517 'Fax: (907)269-7650 November 8, 2002 Robert C. Cowan, C.E. 17034 N. Eagle River Loop Road Eagle River, Alaska 99577 Re: Summit Estates, Lot 16, Block 2 Dear Mr. Cowan: This office received your paperwork for registering the wastewater disposal system serving the duplex on the above referenced property. By submitting the Documentation of Construction, the existing system is approved. I will place the submitted form,s ir/'.o~i' files. Thank you very much for providing us the anformation If you have any questions regarding this matter, please do hesitate to contact us. Sincerely, Environmental Technician