x'#015 - 071 - 22
1976 drainfield cannot be reconnected
because it encroaches in groundwater
(refer to 05P191391 )
Municipality of Anchorage
Sllj)
On-Site Water and Wastewater Section • (907) 343-7904r�� Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORTGGF>'
Permit Number: OSP191391 PID Number: 015-071-22 ,
j?
oe `tel
Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑■ Upgrade
Name
BARB JACOBS &RICHARD MAUER
ABSORPTION FIELD
❑ Deep Trench ❑■ Wide Trench ❑ Bed ❑ Mound
Site Address
5455 EAST 99TH *ANCHORAGE, AK
❑ Other
Phone
Number of Bedrooms
Soil Rating
ITotal depth from original grade
907-830-4111
3
1.2 GPD/SF
7.5 &7.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
SEE DWG. Ft,
Gravel depth beneath pipe
2.02 & 2.02 Ft.
Subdivision Block Lot
SUMMIT ESTATES; BLOCK 3, LOT 10
Fill added above original grade
SEE DWG. Ft.
Gravel length
28 & 27 Ft.
Township Range Section
N/A
Gravel width
5 & 5 Ft.
Beds: Number of Lines
-
Distance between lines
- Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
385+ Ft2
2
6+ Ft.
Well
100'+
100,+
254
TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer Capacity
GREER TANK 1000 Gal.
Surface Water
100' +
100,+
Material
Number of compartments
Lot Line
5'+
*0.5'+
NA
HDPE
2
Foundation
10,+
10,+
ILIFT STATION
Manufacturer
Capacity
Gal.
Remarks OLD TANK DECOMMISSIONED PER UPC PER CONTRACTOR
*WR#OSV191078 - SEE ATTACHED AMENDMENT LETTER
Alarm location
Electrical installed by
ADDITIONAL INSPECTION ON 2/4/2020
PIPE MATERIAL House to tank EXISTIh�1 Tank to D3034
drainfield
Installer
A+ HOME SERVICES
Drainfield D3034 CO/MTD3034
Inspector DAVID GARNESS AND TIM ECKLUND
BENCH MARK (Assumed elevation) 97.98 ft
Inspeection 1s' 11/22/2019 11/22/2019
Location and description
ction 2nd
TOP OF MH
3i° 11/22/16 411111/25/1
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's tamp
0
Conditional Approval: Date
oo* 49T 0
�............... ............ �D
Septic System
t .J f py A�Garnss.:
0
Approved 6�CLu� 6Date
CE-79P3
Note: this approval does not include well permit requirements.
844oODOo0 c)�'
#AECC
(Rev 05/02/18)
PERMIT NUMBER: PARCEL ID NUMBER:
OSP191391 RECORD DRAWING 015-071-22
A I B
MH
65.8
59.4
ST1
70.6
64.7
DBL1
71.8
65.9
DBL2
72.6
66.9
FS
75.8
66.6
C01
69.0
46.2
MT1
67.3
44.5
CO2
73.4
60.2
MT2
74.9
61.4
CO3
97.3
81.5
MT3
95.3
79.5
C04
82.9
74.9
MT4
81.9
73.9
J
100,
W
ELL
SEE ATTACHED LETTER REGARDING THE
DRAINFIELD INSTALLATION; IN ADDITION -WELL
RADAII AND OT LINES WERE FLAGGED BY
SHANE HOCV, PLS PRIOR TO CONSTRUCTION
SUMMIT ESTATES; BLOCK 3, LOT 9 SUMMIT ESTATES; BLOCK 3, LOT 8
10' UTILITY EASEMENT
CO 3 SUMMIT ESTATES; BLOCK 3, LOT 11
MT
DBL1&2 S
S 1 T2
NEW 1000 GALLON \ \
HDPE SEPTIC TANK
M 1
APPROXIMATE
LOCATION OF FCO- \
A
D/U •`� \ I
I.j4. aY
NEW D AINFIELD /
EAS 99TH
10
0,
WELL RADIUS ` � \ I I 1
\ SCALE:
1"=40' _
ILVJ
GARNESS ENGINEERING GROUP Ltd "'�� 4 �•�:'��'.
.....:....................................
ENGINEERING SALES CONSULTING
3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907) 3373179 -FAX (907)338-3246 * WEBSITE: —gamessengin—.ng.cem ......
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: �n •• e f y •• ,,,,,,,,,, arnes ........... e• W "
RICHARD MAUER & BARB JACOBS4_Z1 m
LEGAL DESCRIPTION: DRAWN BY: 907-830-4111 2 OF 3 �j
�/
795 • C •. n /.�a�f e� ����
SUMMIT ESTATES; BLOCK 3, LOT 10 D.J.G. 1� FD'••.,,,,•••• ♦♦
TYPE OF WORK: DATE: LICENSE♦� IDROFESS��P
� SEPTIC SYSTEM RECORD DRAWINGS 2/10/2020 # ECC 84,111vilkikiliL♦♦♦
PERMIT NUMBER: PARCEL ID NUMBER:
OSP151391 RECORD DRAWING 015-071-22
NORTH SOUTH
MT COMT CO
FINAL GRADE = 98.11-99.56 FINAL GRADE = 98.08-98.48
TH#1 ORIGINAL GRADE AT ORIGINAL GRADE AT
TH#1
7 HIGHEST POINT= 96.55 FILTER FABRIC HIGHEST POINT= 97.56
r � r FILTER FABRIC
RELATIVE ELEVATION OF BOTTOM OF T.H. = 80.55
(TH#1 DRY ON 11/21/2019)
GARNESS ENGINEERING GROUP, Ltd
3701 E. TUDOR ROAD. SUITE 101 *ANCHORAGE. AK 99507' PHONE (9071337-6179* FAX (907) 338-3246 • WEBSITE' www uamessennineerinn nnm
PREPARED FOR:
PHONE NUMBER:
fes.-ff • tl
f�f�f•:•:-fes.
PAGE NUMBER:
:f•f-�
•.•f•�•
Sl
gg
•�•.•f-f-• •f •1
1
:�:�:
- •-•--:•:•:•-•:•INVERT
OF 1 1
(THROUGHOUT DISTRIBUTION LINE)
•••••
f•.�:•••••-•'•'f
-•'•••'•'•••-•
0.
D.J.G.
TYPE OF WORK:
:�:
�f�:�f�f�L•�•�1d
�, RECORD DRAWING
1J�b:
�:�:J.-.:�:�:�:�f�:tel
BOTTOM •
:• • •
TRENCH = 89.05
•1 1.
RELATIVE ELEVATION OF BOTTOM OF T.H. = 80.55
(TH#1 DRY ON 11/21/2019)
GARNESS ENGINEERING GROUP, Ltd
3701 E. TUDOR ROAD. SUITE 101 *ANCHORAGE. AK 99507' PHONE (9071337-6179* FAX (907) 338-3246 • WEBSITE' www uamessennineerinn nnm
PREPARED FOR:
PHONE NUMBER:
PAGE NUMBER:
RICHARD MAUR AND BARB JACOBS
907-830-4111
3 OF 3
PROJECT/LEGAL DESCRIPTION:
DRAWN BY:
SUMMIT ESTATES; BLOCK 3, LOT 10
D.J.G.
TYPE OF WORK:
DATE:
�, RECORD DRAWING
2/10/2020
RELATIVE ELEVATION OF
BOTTOM OF T.H. = 81.56
(TH#1 DRY ON 11/21/2019)
X41,
■..,
�....., ,..�.A. ...................0
' J9ffrey Gamess a _v ff
CE .7953 �
•
LICENSE 141kim\\\�•••O
#AECC884 /
r7PERMIT NUMBER: RECORD D RAW I N G PARCEL NUMBER:
OSP 191391 015-077 1-22
TOP OF MH = 97.98
FINAL GRADE = 97.8-98.02
MH ST2
TOP OF TANK AT INTLET = 93.91 TOP OF TANK AT OUTLET = 93.91
NEW 1000 GALLON
INVERT OF BUNG AT INLET = 93.22 H. D. P. E. GREER INVERT OF BUNG AT OUTLET = 93.11
SEPTIC TANK RATED
FOR 10' BURIAL
l ■VAI
ARNESS ENGINEERING GROUP, Ltd ;...................... ............;
_--- ENGINEERING D SALES 3 CONSULTING - --
3701 E. TUDOR ROAD. SUITE 101 -ANCHORAGE, AK 99507' PHONE (907) 3376179 -FAX (907) 336-3246' WEBSITE: www. gamessengineedng.com „ „
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ffrey A.••,, .....arness •:•
BARB JACOBS AND RICHARD MAUER 907-830-4111 4 OF 4 �jG'i • JE -79 3 '�LEGAL DESCRIPTION: DRAWN BY: �� O �\ V
SUMMIT ESTATES; BLOCK 3, LOT 10 D.J.G. �j'QF�••••••. ,,,,••�� ��
TYPE OF WORK: DATE: LICENS? 4"J :;`S`;�.�
SEPTIC TANK PROFILE 12/2/2019 #AECC884 4 1%k
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING- SALES c, CONSULTING
February 10, 2020
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Summit Estates; Block 3, Lot 10 — Re -inspections and movement of drainfield
To whom it may concern:
Prior to installation of a new drainfield on the subject property, a pre -construction layout was
performed. During the layout, what was believed to be a surveyed easement, was in fact a
surveyed lot line. After receiving the post -construction as -built survey, it became apparent that
the new drainfield encroached 5' feet into the utility easement. Per conversations with the
owner, Barb Jacobs, she would not sign the letters of non -objection and required that the
drainfield be moved. On 2/4/2020 A+ Home Services excavated and "moved" the existing
drainfield outside of the easement. Garness Engineering and MOA onsite employee Tim
Ecklund performed inspections of the drainfield. Attached is a survey by Shane Holt, PLS
showing the new grainfield pipes outside the easement.
a
.E., M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
N 89 5730 " E 120.00
EAST 99TH A VENUE
OF A eq�040
x..`49 TH '.90
SHANE A. HOLT a9
-6914 .,'c y
\h°fessional L-65
AS -BUILT SURVEY I " = 30'
NO CORNERS SET THIS DATE
I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
LOT 10, BLOCK$ SUMMITESTATES
FB
HOLT LAND SURVEYING
9309 GROVER DRIVE
ANCHORAGE,AK 99507
ANCHORAGE RECORDING DISTRICT, ALASKA,
AND THAT THE
THE INFORMATION HEREON IS FOR
CONFLICTS BETWEEN EXISTING
THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY
STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS
VISIBLE IMPROVEMENTS SITUATED THEREON
ARE WITHIN
NOT TO BE USED FOR POSITIONING
ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENC ELINES.
THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
EASEMENTS OF RECORD, OTHER
THAN THOSE APPEARING ON THE RECORD PLAT ARE NOT SHOWN
EXIST OTHER THAN NOTED.
HEREON ( UNLESS INDICATED)
DATED AT ANCHORAGE,ALASKA THIS 6TH
DAY OF
NOTE: FENCELINES THAT MAY
APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE
FEBRUARY 2020
PROPERTY LINES OR POSITION
ADDITIONAL IMPROVEMENTS.
,
ANY PAVING SHOWN HEREON MAY
BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE.
FB
HOLT LAND SURVEYING
9309 GROVER DRIVE
ANCHORAGE,AK 99507
MUNICIPALITY OF ANCHORAGE
rJ� ,lryl e,!)j
/ • \ On-Site Water&Wastewater Program �,. . ..,S��
rate, PO Box 196650 4700 Elmore Road
, Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ,mayr.
http://www.muni.orgtonsite
4
\ ..
t.)Npill'ttill`Ilt
4',CHOR p•GE
On-Site Wastewater Disposal System Permit
Permit Number: OSP191391 Effective Date: 9/11/2019
Work Type: Septic Upgrade Expiration Date: 9/10/2020
Tax Code Number: 01507122000
Site Legal Address: SUMMIT ESTATES BLK 3 LT 10 G:2437
Site Mailing Address: 5455 E 99TH AVE, Anchorage
Owner: MAUER RICHARD D & Lot Size in Sq Ft: 15662
Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3
This permit is for the construction of:
Q Disposal Field Q Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: Date: / l 1
7
Issued By: � e( Date: atAy/
/ ,r „�
of
Municipality of Anchorage I
'` n
,� I.epAI MICHt
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://www.muni.orq/Onsite
Development Services Department
On-Site Water and Wastewater Section
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSV191078 COSA#: Permit#: OSP191391
PID#: 015-071-22
Legal Description: Summit Estates Block 3 Lot 10
Engineer: Garness Engineering Group
Applicant: Richard Mauer& Barb Jacobs
Your request for a waiver of the required 10 feet horizontal separation from the
absorption field and septic tank to the property line has been approved. The approved separation
distance is 0.5 feet. In addition, your request for a waiver of the required horizontal separation
between the proposed absorption field and the existing absorption fields that is to be abandoned
is approved. The approved separation distance is 5.0 feet. See engineer's waiver request for
justifications.
This waiver approval applies to the proposed absorption field and septic tank only. Any future
upgrade to the on-site wastewater disposal system will require all separation distances be met or
another approval from this department.
'
Waiver is Granted: X Waiver is not Granted:
Date: _244____ Approved by: diurz&
PP
Name of Reviewer
**** VARIANCE/WAIVER REVIEW ****
5 6 7 8 8 10
MUNICIPALITY OF ANCHO
. ,r�
Community Development Department 46 / P1'; 907-343-790-.
Development Services / 'y : 907- 343-7997w
On-Site Water & Wastewater Program 61
Mayor Dan Sullivan
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. 015-071-22
Property owner(s) RICHARD MAUER&BARB JACOBS Day phone 907-830-4111
Mailing address
Site address 5455 EAST 99TH 'ANCHORAGE.AK 99516
Legal description (Sub'd, Block & Lot) SUMMIT ESTATES; BLOCK 3. LOT 10
Legal description (Township, Section & Range)
Lot Size Sq.Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING:
(®all that apply) Initial ❑ Single Family (SF)
Absorption Field ® (w/wo ADU)
Septic Tank ® Upgrade Duplex (D) II
Renewal ❑
Holding Tank ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
SEPTIC TANK AND DRAINFIELD TO LOT LINE Distance' 0.5
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: c5-95 Waiver Fees: p` 7
Date of Payment: (OM _ Date of Payment: 60/19
Receipt Number: n03/21 C) Receipt Number: O31?
Permit No. 06Piq/y `/ Waiver No. OO V IQ i 5O�p
(Rev.01/11)
i !G `
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING SALES CONSULTING
September 11"', 2019
Municipality of Anchorage
Development Service Department
On-Site Water&Wastewater Program
4700 Elmore Road
Anchorage,AK 99507
Ref: Proposed Septic System Upgrade for Summit Estates; Block 3, Lot 10
To whom it may concern:
The existing 3-bedroom house is served by a private well and septic system. Per MOA records, the septic system
was installed in 1976. An adequacy test was attempted on the subject drainfield and it was deemed to be failed
because the liquid level in sump and septic tank were at approximately the same elevation. During the excavation of
the testhole, a new cleanout and monitoring tube were installed in the existing drainfield, after which it was
determined that the existing drainfield encroaches on groundwater, and the configuration of the drainfield does not
match the MOA records; therefore, we are proposing to decommission the existing septic tank and drainfield and
install a new 1000-gallon HDPE Greer Tank septic tank(rated for 10' burial) and dual shallow trench type drainfields.
One testhole was excavated and the drainfield is proposed within its 30-foot radius. Comments regarding the design
are summarized as follows:
1. SOILS: See attached 2019 testhole by Garness Engineering Group, Ltd. which shows the soil classifications,
percolation test and groundwater monitoring.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: There are no topography concerns.
5. WAIVERS: The proposed drainfield and tank are less than 10 feet from the lot line. We request that your
department issue a variance of 0.5 feet from the drainfield and septic tank to the lot line. Additionally, the proposed
drainfield may be less than 10 feet from the existing drainfield, therefore we are requesting a 5' variance.
Justifications for granting these waivers are as follows:
• The proposed tank and drainfield will meet MOA code required separation distances from the well and septic
system located on the lot to the east(Summit Estates; Block 3, Lot 11)
• The lot line waiver will help maximize the separation distance from the existing drainfield and septic tank
• The proposed septic tank will be further than the existing septic tank from the well.
• The proposed septic tank will be HDPE
• The existing drainfield will be abandoned in place,therefore,a 5'separation distance will cannot effect future
performance
• After the primary treated effluent reaches the abandoned drainfield, it will have passed through 5 feet of soil,
thus improving the effluent quality and limiting the risk of groundwater contamination.
• Water samples were pulled by GEG on 7/16/2019. Nitrate levels were 0.263 mg/L.
We are unaware of : 'y adverse impacts this installation and/or waivers would have on adjacent wells or septic
systems. If you =v: a questions, please contact us at 337-6179.Thank you for your assistance.
i-rely
. -y i. /mess, P.E , M.S.
Pr: d:` t
1
3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259
Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com
A X\ // // /// \._,.--------------A---------3 LL-,J---1
O
00 <\/) -10()
El
_ \
- , ...-- C- ---.... 0— ___
/
// �\ \� �/ EAST 98TH \\\
/00,w, )pO,WF \
I CC RAD i,d l 1�wF<<R I
I �. Us 1
\ SUMS ESTA \ /
I , I
BLOCK 4,LOT\ \/ D J mi
\ /\
/
\ / \ SUMMIT ESTAT, S MIT ESTATES;
/ BLOCK 3y0 9 BL K 3,LOT 8
r
EMIT E ATES.
•CK4. e T 2
\ / SUMMIT'ESTAJJK \ \
/ \ BL,'CK L6T 11 \
1— 109: ELL RADI S \I / \
/ \
\ l / / / \ Eil
l 70p•W SUM IT ESTAT �\ %//l�iiiit, / /
%� 1 I
ECC D7U BLS CK 4.LOT / 1 r wCL , — ---• 700, FCC •
'weCC RA
/ II AD /U
vim_ _ , / / \ \ I`� \, EAST 99TH / /
4
7pp,�� rr wFCCR 7 \ �/ \ \ \ //
1 �1 .l
I I S
SUMMIT ESSUMT�STATE9�`
.--BLOCK-1",LOT 5� BLOLK 4,CST f� :I`•T• N
O41111P'
11111
I,M LA
Q SUMMIT ESTATES; — SCALE:
BLOCK 4,LOT 4 \ /
1 .17:,
„„„ • •
\\\ 111
41:r C
Air t \ c '
* �� ' *••�
GARNESS ENGINEERING GROUP, Ltd •; ' I.
440
•
MINIIIIIMINIIIIMMISC ENGINEERING SALES CONSULTING • - 0ifr
0
3701 E.TUDOR ROAD.SUITE 101'ANCHORAGE.AK 99507'PHOPE(907)337-6179'FAX(907)3383246'WEBSITE.wvnv garnesseng,neenng corn �.•••• •••1• ;
PREPARED FOR PHONE NUMBER: PAGE NUMBER: 0 vry : J.1 - Gam= s j.
RICHARD& BARB JACOBS 907-830-4111 1 OF 2 �•�� , 7-79r '•_�
PROJECT/LEGAL DESCRIPTION DRAWN BY: •� c , '`.''(`SUMMIT ESTATES; BLOCK 3, LOT 10 D.J.G. �.4, 4 "'•••••.• ((��\, 4•�
TYPE OF WORK: DATE LICENSE,,4',%„S`* �••
SEPTIC SYSTEM DESIGN UPGRADE 8/27/2019 #AECC884 J
J 1
DESIGN CRITERIA: GEG.Ltd.HAS AN 8 PAGE SPECIFICATION LETTER — NOTE:THE CONTRACTOR
THAT PERTAINS TO THIS DESIGN.BY PROCEEDING SHALL HAVE THE NORTH&
NUMBER OF BEDROOMS:3 FORWARD WITH THIS INSTALLATION,THE EAST LOT LINES,AND ALL WELL
GALLONS PER DAY(GPD):450 GPD ENGINEER,WELL DRILLER,CONTRACTOR AND
PERCOLATION RATE/S:2.1 MIN/INCH PROPERTY OWNER AGREE THAT THEY HAVE RADII FLAGGED BY A
PROPOSED APPLICATION RATE:1.2 READ THESE SPECIFICATIONS AND AGREE TOREGISTERED LAND SURVEYOR
MINIMUM DRAINFIELD SQ.FT.:375 FT' ACCEPT THE TERMS AND CONDITIONS OUTLINED. / PRIOR TO CONSTRUCTION.
DRAINFIELD DESIGN: SUMMIT ESTATES;BLOCK 3,LOT 9 V
MAXIMUM DEPTH:7.5 FEET /
WIDTH:5 FEET
LENGTH:54 FEET(2(8Q 27 FEET) /
EFFECTIVE:2 FEET
REDUCTION FACTOR:0.7
ACTUAL SQ.FT.:385 FT' APPROXIMATE LOCATION OF POWER POLE SUMMIT ESTATES;BLOCK 3,LOT 8
(ASSUMED 10'EASEMENT IN THIS AREA)
APPROXIMATE LOCATION OF EXISTING\ iii — — — —
w DRAINFIELD;DOES NOT APPEAR TO BE 10'UTILITY EASEMENT SUMMIT ESTATES;BLOCK 3,LOT 11
CONSISTENT WITH MOA RECORDS s\--r—
N
I-I- z APPROXIMATE LOCATIO OF EXISTING SEPTIC g+ 0.5'LOT LINE WAIVER r -
LU TANK;TO BE DECOMMISSIONED PER UPC 18�• REQUEST FOR TANK
\ w s M H# �, AND DRAINFIELD j /
> /---.'
/510% ��� M GJ
Dm _ F � r-
\ N I 7 .O T . ------- /
H T� { 1*/
/I WAIVER REQUEST PROPOSED 1000 GALLON HDPE GREER
I TANK RATED FOR 10'BURIAL;INSTALL
/ I \ DOUBLE CLEANOUTS BEFORE AND AFTER
I NO
0 /
O Q
Y
U
7\ / ,
/ 9 / EXISTING 3 A ••'
co BEDROOM
w 70p•WF( / HOUSE _ .• \ I
/ I-
~o
`�1V3 / / ,
.,t4:,` I
•::.: ,
/ / EAST 99H AVEN E// 1
\ \ 1(\
--4
7p0Wec \ 7p0Wf..LRAOIU / \ N
t RgDI(/ \ S
S \ / \ \
I SCALE: \
SUMMIT ESTATES;BLOCK 4,LOT 5
I SUMMIT ESTATES;BLOCK 4,LOT 6
i ''''' , /\./ \ / I I —
i t V.
I
4t; `IN I 0— ,*
• , •'' .
GARNESS ENGINEERING GROUP, Ltd •:•••..:..•. ••
ENGINEERING SALES,CONSULTING • „ •
3701 E.TUDOR ROAD,SUITE 101•ANCHORAGE.AK 99507 PHONE(907)337.6179•FAX(907)338-3246•WEBSITE:www garnessengmeenng corn PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 fn I'•••-y •• /eSS
RICHARD MAUER &BARB JACOBS 907-830-4111 2 OF 2 ♦��!J,i I...
C -7 53 ;•*=PROJECT/LEGAL DESCRIPTION: DRAWN BY: •
SUMMIT ESTATES; BLOCK 3, LOT 10 D.J.G. ♦1♦,I •
'•l �. 1'�P::.•�
TYPE OF WORK: DATE: LICENSE,, 1 PROF. "�_�
SEPTIC SYSTEM UPGRADE 9/10/2019 #AECC884
OF
s- • I 4 ,♦♦♦i
(FARNESS ENGINEERING GROUP, Ltd : - ' 9t.r____v -: ••
3�oie.ruooRRono.suir. _.1nracNowENGGE.AK 95NEERI07•PHONE NG3�SALE179•FAX� 3CONSULTING2S5Qn�neP^ycJm
.. ..
�t v , .i= .ey,A. Ga4ss , =
SOIL LOG - PERCOLATION TEST v. , :%� CE-79153
LEGAL DESCRIPTION: SUMMIT ESTATES;BLOCK 3.LOT 10 �.:�FO ,p i 13 j I C!•;�c:.
PERFORMED FOR: RICHARD MAUER&BARB JACOBS DATE: 8/1/2019 q�� PROFESS" "-
DEPTH #AECC884 11,��",'••
(feet) TEST HOLE #1
;1;;
1 .:-.
• �� SOIL CLASSIFICATIONS SITE PLAN
2
r • :=Td o`4 GW ::=::::::=:__ ORG
r Er-?.e
• r �' GM ) MI
l CI
4 � • r /i GC �I OL Q-
• . °o o°o°° SW I
MH• •e•ego•* SP CH r • • SM OH
• r #1.. . .9 SC ��Q
6 — • • PG
r N
• DEPTH TO
•
F. GROUNDWATER 'n I �xr
())(
I GJ
8 ' r • 15' 8/1/2019
r
I 14.5 8/6/2019 SCALE:
r
9 • r 14.3 8/9/2019 1'=100'
r •
10
• r
r • ( M I ; • READING CLOCK NET TIME WATER LEVEL NET DROP
11 r • TIME (MINUTES) READING (INCHES)
I r 8/6/2019 1 3:45 - 6" -
12 • r
• 2 3:55 10 1-1/4" 4-3/4"
• I -
13 — r3 3:55 6" -
• 4 4:05 10 1-3/8" 4-5/8"
I
14 r 5 4:05 - 6" -
I r
rr 6 4:15 10 1-3/8" 4-5/8"
15 • • 7 4:15 , - 6" -
• • 8 4:25 10 1-3/8" 4-5/8"
16 -
B.O.H. 9 4:25 - 6" -
17 10 4:35 10 1-3/8" 4-5/8"
11 4:35 - 6" -
18 — 12 4:45 10 1-3/8" 4-5/8"
19 _mil PERCOLATION RATE 2.1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 4 FT. AND 5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES El NO
SOILS LOGGED P": DAVID GARNESS PERCOLATION TEST PERFORMED BY: ERIK WIDGER
COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH.
PERFORMED BY GEG, Ltd. I. JEFFREY A. GARNESS. CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: v ) r.3//'
,SG$
SGS Ref.# 1193857001
Client Name Gayness Engineering Group,Ltd(GEG) Printed Date/Time 07/24/2019 8:24
Project Name/# Summit Est.B3 L1 Collected Date/Time 07/16/2019 16:15
Client Sample ID Summit Est.B3 LIO Received Date/Time 07/16/2019 16:43
Matrix Drinking Water Technical Director Stephen C.Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date In it
Metals by ICP/MS
Arsenic ND 5.00 ug/L EP200.8 B (<10) 07/19/19 07/22/19 DSH
Waters Department
Total Nitrate/Nitrite-N 0.263 0.200 mg/L SM21 4500NO3-F C (<10) 07/17/19 EWW
Microbiology Laboratory
E.Coli Negative 1 100mL SM21 9223B A 07/16/19 ACF
Total Coliform Negative 1 100mL SM21 9223B A 07/16/19 ACF
4
N 89 57'30"E 12000
10'VIA/f'EASEMENT
i
•. 0.
I's,.
•
O
v , O
l'',... o
O
jO o
2
DECK 1111'`•.
.E FPM��SE
„No 'r 72\8
ot ■ DECA III > `,
Tr 0
°WEIL
Sp, . ooODOp %
N8957'30" 70.00 Ov�� OF A��S�O
i�49 TH %1\ vo
OQ
D
EAST 99TH AVENUE • '°
L.�———.—.——.——.——.—.—.—.—.—.--.—.——.————.�———----————._ oO a SHANE A.HOLT .':,
" % • LS-6914 .•.5� 9
44��DO0000�-60
AS-BU/LT SURVEY I" -30'
NO CORNERS SET THIS DATE
I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
i
101/0 830(13 SUMM/T ESTATES
THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE
CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN
NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN EXIST OTHER THAN NOTED.
HEREON I UNLESS INDICATED) DATED AT ANCHORAGE,ALASKA THIS 22ND DAY OF
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE AUGUST , 2019
PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS.
ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE.
HOLT LAND SURVEYING
9309 GROVER DRIVE
ANCHORAGE,AK 99507
1.''.2 -R g9-//) 345-5513
GRE, ., ER ANCHORAGE AREA BOR,, GH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
SEPTIC TANK:
DISTANCE
FROM WELL
INSIDE LENGTH
MANUFACTURER ~ MATERIAl
INSIDE WIDTH LIQUID DEPTH
NUMBER OF
COMPARTMENTS ~-
LIQUID CAPACITY/~r) GALLONS.
TILE DRAIN FIELD: ¢~~
DISTANCE FROM WELL FOUNDATION
NUMBER OF LINES / DISTANCE BETWEEN LINES
NEAREST LOT LINE
TRENCH WIDTH
TOTAL LENGTH
OF LINE'S
IN. TOTAL EFFECTIVE
ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE
DEPTH OF FILTER
DEPTH: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE_
IN. ABOVE TILE IN.
WELL: .
TYPE ~6YV~,W~
BUILDING
FOUNDATION
CESSPOOL
APPROVED
CONSTRUCTION
NEAREST NEAREST
LOT LINE , SEWER LINE__
OTHER SOURCES
DISAPPROVED REMARKS
DEPTH
SEPTIC SEEPAGE
, TANK SYSTEM
DISTANCE FROM:
DISTANCES:
DIAGRAM OF SYSTEM
INSTALLED BY:
SEWER LINE DEPTH:
PIPE MATERIAL'
LOT SLOPE:
REMARKS:
DATE PPROVED
~ G.A.A.B.
PERMIT
[:,EPRF.:TMENT., ; HERLTH ..... = "' ;"
MhtL. EIq,IKuiqrIEN~HL., ,dJIEL. fluN
;.25':L6 E.*"¢UE:,0R RE:,. ............... ~
., HNL:I'-ILIRHI:iE., l-iH:.. :¢_~3~1,." ~ /'ff,',~)O
~.4 E b L F:~ N E:. u ~ ,,~ .... Z "fi-' E: "--=. ~:: g....~ E. F~." F" E F~: F~'~ :E T'
,. -.. ........... ~ )
RPPLICRNT
LOC:BT I ON
LEGRL
[.~!] N Dt::IHL
SUHMIT STREE].'
Lie B:~: SUMfqIT EST
SRR BO',:.,', 78
'T'"r'F'E OF' SOIL RBSORBTION S'gSTEM IS: TRENCH
LOT '.5 Z ZE
:1.4:1.75 SQURRE FEET
MR:dlMUM NUMBER OF BE[:,ROOMS = ]~
:E;OIL RFI]"ING (SQ PT,.-"BR)= E:5
THE REQUIRED SIZE OF ]''HE SOIl_. RB:=]ORPTIOIq SYSTEM IS:
[- EF ] H-- :~_.e~ L.E:["-.~,]T'H= --' -' -" ," -
THE LJENGTH DIMEN':-]ION IS THE L. ENGTH '-'.'IN FEE]") OP THE TRENC:FI OR DRRINF:ZEL. D.
'THE [-"EPTH OF R TRENC'H OR PIT IS ]-HE [:,ISTf:INC:E BETI.,.tEEN THE SURf:laCE 01:= THE
GROUND RN[:, THE BOTTOM OF THE EXCRVRTION (IN FEET).
THERE tS NO SET HIDTH FOR TRENCHES.
'TIDE GRFCv'EL DEPTH IS THE HINIHUM DEF'TH OF GRI:I',,,'EL. BE'TI.4EEN ].'fiE OLITFFILJ.... PIPE
RND ]"HE 6'O'I"TOI'4 OF THE EXCRVRTION ,::IN FEE'r).
BRCKFILLING OF 8N'¢ S'¢STEM WITHOUT FINRL INSPECTION RND RPF'ROVRL BY THIS
[:,EPRR"rMEI'4T HILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTRNCE 8ETNEEN I-~ WELL FIN[.., AN'?' ON-'=;ITE SEI4RGE DISI::'OSRL SYSTEH IS
±()0 FEE]' FOR R F'RI',,,'RTE NELL OR. 2~...--.1E~ FEET FOR R PUBLIC WELL
WELL LOGS RRE RE6!IJIRED RND r,~us-r BE RETURNED TO THE: DEF'RRTMENT WITHIN :~:E~
OF THE WELL COMF'LETION.
SPECIFtCRTIONS RND CONSTRIJCTION DIRGRRMS RRE R',,,'RIL. RBLE TEl INSLIRE F'ROPER
I NSTRLL. RT ION.
I CERTIF"r' THRT
:L: I RM F'RMILIRR t4ITH THE REQUIREMEN].'S FOR ON-L=;ITE SEI.qERS RND I.,IEL.LS RS SET
FORTH E:"r' THE HUNICIPRLIT'¢ OF' RNCHORRGE.
2: I WILL Ii'4STRLL. THE S"r's'rEM IN RCCORE)RNCE HITH THE CODES.
3:: I UNDERSTRND THRT THE ON-SITE L=;EI.4ER S'¢STEH I"'IR'¢ REQUIRE ENLRRGEMENT IF' THE
RE=,IE. ENL. E. I_, REflu£.EL. EL. ~0 1NL..LIJDE NJRE THHN ~. E, EE.F..uUll ....
I
-RPPLICFINT DON [:,RI-IL
October 19, 1976
R & M No. 656314
Mr. Don Dahl
SRA Box 78
Anchorage, Ak 99507
REf Test Hole and Soil Log Report for Sanitary System,
Summit Estates Subdivision, Block 3, Lots 9 & 10, Anchorage, Ak
Dear Mr. Dahl:
We are submitting herewith the test boring results and our con~ents
regarding soil conditions encountered at the subject site. This in-
vestigation was performed in accordance with your request of October
15, 1976 and those procedures outlined in a letter dated July 15, 1975
by Mr. Rolf Strickland of the Municipality of Anchorage, Departraent
of Enviromental Quality.
Two test holes were bored, one on Lot 9 and one on Lot 10, for the
purpose of defining general subsurface soil conditions for the proposed
sanitary systems. Drilling was accomplished with an auger type drilling
rig and the test holes were extended to a total depth of 19 feet, each,
below ground surface. The final log prepared for the test holes has
been included in Drawings A-01 and A-02.
Groundwater was not encountered in either test hole while drilling.
We appreciate being given this opportunity to be of service to you.
Should you have any questions with regard to the above, please do not
hesitate to contact us.
Very truly yours,
R & M CONSULTANTS, INC.
Vice President
JWR/pe
xc: Municipality of Anchorage
EAST NIneTIETH AVENUE
Lot 9
TE-2
Test Hole Locations in Summit
Estates Subdivision, Block 3
Lots 9 & 10, Anchorage~ Ak
Test Hole Location are
approximate and have not
been located by survey methods.
TEST HOLE LOCATION DIAGRAm!
DON DAHL
ANCHOPAGE, ALASKA
JLOW~UO.
656314
A-O1
TH-1
10-18-76
0.0
ORGANIC SILTY SAND,
Dark Brown 1.0'
TH-2
10-18-76
ORGANIC SILTY SAND
Dark Brown
Boulder at 3'
SANDY GRAVEL (GW) /
Many Cobbles ~
Brown
Boulder at 4'
7o5~
GRAVELLY SAND (SW) /
Occasional Cobbles, /~
Brown
SANDY GRAVEL
Many Cobbles,
Brown
Boulder at 9'
12.0'
SAND W/S0}~ GRAVEL (SP)
Occasional Cobbles,
Brown
14.0'
SANDY GRAVEL (GW)
BroWn
15.5'
GRAVELLY S~]~D W/
TRACE SILT (SP)
Brown
No Water Table
GRAVELLY SAND W/
TRACE SILT
19.0' TD 19.0' TD
Water Table
These Logs represent subsurface soil
conditions within Summit Estates
Subdivision, Bloc}: 3, Lots 9 and 10
Anchorage, Alaska
SCALE: /"='3 !
TEST HOLE LOGS
Anchorage, Alaska J[DWG~0. A-02
WATERVELL LOG
July 18~ 1978
.VROPER TY OV~.fER:
Don Dshl (contractor)
DBTYJ,ING- CONTRACTOR:
Cook ~alet Enterprises
LOCATI0~ OP VEAL:
Lot 1% Bik. 3 SLu~Lt Subdivision
DEPTH OF
306'
DIA?~T~3H O~ %TDiJj:
6!!
DRLLLING LOG:
0 - 27'
27 - 65'
65 - 97'
97 - 105'
104'- 141'
151 - 168'
168 - 186~
186 -
190 - 506'
306'
s.andi,,,' grs~¢el aud some cle.y
ttua%ig to prove clsy
ol~ ~d gravel t~n%~ to p~e clay
seepsge~ s~prox~ateDy 1 g~./~n, no head
pu~e olsy~ some gravel
c],a3~ ~nd grsr~'el
oo~se gms~el end clay
ol~: ~cl gcoavet
clash gr~3¢el a93,~ifer
STATIC LEVEL: f~l~.OXl~i&Tl~I,Y 90' ~t{%~. )?DTTOI~
YIELD: 7 g$[o/min. 10' head.
DRILLER: J~I E/~ROL COOK
TRUE TO THE BEST O~
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering Group Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 ,
Engineer's Printed Name: Jeffrey A. Garness Date: 0 Cl
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and �oo�oOp�
industry practices. The reported results describe the condition of the system/s on the date/s of the o� OF
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or o ..• ""' jq���4
encroachments may exist that were not identified during the evaluation. The operational life of all wells QUO P / t , r �jll
and septic systems depend upon a variety of variables, including but not limited to, soil conditions, V
groundwater levels (that may fluctuate during the year), quality of construction (materials and Q — Q
9 TH t
workmanship),and the water usage of the family utilizing the s stem/s. These conditions can vary, �'"""" "'"'""""�
9 Y 9 Y ry, and G
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of;ti; • • • • • • • • } G
the well or septic system. GEG makes no representation whether an alternative well or septic system �Q '.�e�f y A� G'ess.,
can be installed on the property in the event either of the current systems fail to perform adequately in_CE 7753
the future. The content of this report is for the sole benefit of the person/party that retained GEG tosf A
perform the evaluation. Reliance upon the information provided in this report by any other person or OQ� Pap �otessl3" 5 on
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right �0 o
whatsoever.
#AECC884
6. DSD SIGNATURE
System #1 Approved for bedrooms ``l
System #2 Approved for bedrooms `�QP��V OF,Q,y��i/moi/
Disapproved _` ON-SITE%
Conditional approval for bedrooms, with the follows tipl.WWBR AND
t,— Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
11
Legal Description: SUMMIT ESTATES; BLOCK 3, LOT 10
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 7/11n8
Total depth 306 ft
Cased to UNKNOWN ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 116/19
Static water level at beginning of test 270.6 ft.
Comments
B. TANK DATA
Age of tank(s) 0.5 years
Tank type/material ...7m'�'
Measured operating fluid level in septic tank NEW
❑ Standpipes/foundation cleanout per record drawing
Date of pumping NEW
D. ABSORPTION FIELD DATA DUAL TRENCH
Which system tested (date installed) ""e Lw°
❑ ALL standpipes present per record drawing
Total measured depth from grade 10.5 ft (max)
Measured depth to pipe invert from grade 6.0 ft (min)
❑ NIA — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Parcel ID: 015-071-22
Structure served by this system 1
Well production at time of test 5.3+ gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test? ❑ Yes ❑ No
RColiform bacteria is Negative
Nitrate �'u-?`mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L 5<Arsenic less than MRL (ND)
Collected by GEG, LTD.
Date of Sample 5/29/20
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments: N/A
Adequacy test date NEW
Results ❑✓ Pass For 3 bedrooms
Fluid depth prior to test NEW in
Water added NEW gal
New depth NEW in
Elapsed time NEW min
Final fluid depth NEW in
Absorption rate 450+ gpd
Any rejuvenation treatment (past 12 months) NONE
N/A N/A
Gallons introduced gallons If yes, enter date
Comments/Deficiencies: SYSTEM NOT TESTED -ALL MONITORING TUBES DRY ON 5/29/20
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
Q
Yes
Community Sewer Manhole/Cleanout > 100'
�✓ Yes
if No
ft
® Yes
if No ft
Neighboring Tank > 100' Q Yes
if No
ft
Private Sewer/Septic Line > 25' Q✓ Yes
if No ft
Absorption Field on Lot > 100' Q✓ Yes
if No
ft
Holding Tank > 100' Yes
if No ft
Neighboring Absorption Fields > 100'
Q Yes if No ft
Water Main > 10'
Animal Containment > 50' Q Yes
if No ft
Q✓ Yes
if No
ft
Q✓ Yes if No ft
Water Service Line > 10'
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway
Community Sewer Main > 75' P1 Yes
if No
ft
Q Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
Q
Yes
if No
ft
Surface Water > 100'
Q Yes if No ft
Property Line > 5'
F71
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
Q
Yes
if No
ft
Private Wells > 100'
Q Yes if No ft
Water Main > 10'
Q
Yes
if No
ft
Community Wells > 200'
Q✓ Yes if No ft
Water Service Line > 10'
Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
❑✓
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
Q
Yes
if No
*0.5+ ft
Wells on Adjacent Lots:
Water Main > 10'
Yes
if No
ft
Private Wells > 100' Q Yes if No ft
Water Service Line > 10'
F�
Yes
if No
ft
Community Wells > 200' Q Yes if No ft
Surface Water > 100'
Q
Yes
if No
It
F. ENGINEER'S COMMENTS
*WR#OSV191078
G. ENGINEER'S CERTIFICATION
l certify that l have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
r"
J y A. Glarness;
139. ' .�CE17 53 y
rofess0 o�
#AECC884 w000d� _ rf�
[~IUNICiPALITY OF ANCHORAGE
DEPART~ENT OF HEALTH AND ENVIRONDIENTAL PROTECTION
DIVISION OF ENVIRON&'IENTAL H,~ALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
GENERAL INFORtViATION
(a)
Legal Description ( nc ude ct, b ocq subdivision, section, township, range)
._7
Location (address o~ directions)
(b) Applicant Name ,-~-~"'¢~4*.¢~'~n'n~~;¢' ~./~2..c-¢~_ Telephone: Home ~-~'z¢~(~--'~/~'77_ Business
Applicant Address
(c) Applicant is (check one): Lending Institution ~; Owner/builder ~/'; Buyer []; Other [] (explain);
(d) Lending Institution b~~'~/LCL'~'/'(~;~- ~S¢/¢.:eFephone
Address
(e) Real Estate Company and Agent
Address
Telephone
(f) Mail the HAA to the following address:
2. TYPE OF RESIDENCE
Single-Family [~Multi-Family [] Other
3. WATER SUPPLY
Individual Well ~Community ~ Public ~
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
SEWAGE DISPOSAL
Onsite [~'Public D Community E] Holding Tank D
Note: It community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page I of 2 72 025 (11/84}
5.ENGINED'lING FIRM I~ROVIDI!~.~Ii",ISPECTIONS, TESTS, FILE SEARCH, [~,~A AND INFOP¢]IATION
As ceHifiod by my seal affixed hereto and as of the validation date shown below, I verify that my ~nvestig~'tion of this Hoalth
Aut hori[y Approval shows that the on-site water supply and/or wastewater disposal system is safe, funct~pnal and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the in~prm~tion obtained
. from the Municipality of Anchorage fifes and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection. ,
Name of Firm ~/-~'~ ~- ~ Telephone
Date ~/Z/,~' ~'
ineer's Seal
DHEP APPROVAL
Approved
for
Y ,~ ~
Approved Disapproved Conditional
Terms of Conditional Approval
Date ~¢/~-~ ~'
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in pararJraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (~ 1184)
wELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720
- Legal Description: '~'~'7z/-~,
MUNICIPALITY OF ANCHO,~,\G~
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECT[ON
1986
TotalDepth .~O~ '~ Casedto .~,~o Depth of Grouting
Static Water Level ¢-'~ '~ _%? Pump Set At
Casing Height Above Ground ~-/" Sanitary Seal on Casing (Y/N) ..~¢'
Y~-¢ Depression Around Wellhead (Y/N) ,'~/~
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
-¢ '
-b ; On Adjoining Lots
To Nearest Edge of Absorption Field on Lot ''~ / ~'o ; On Adjoining Lots
To Nearest Public Sewer Line ,/~,"¢ To Nearest Public Sewer
Cleanout/Manhole ~//~ To Nearest Sewer Service Line on
Water Sample Collected by .~;¢-/.,'.¢'-7-' ; Date
Water Sample Test Results ~"¢~"~/~-'¢'7~'~'1~"¢¢
Comments ¢ Z,?' "%-
SEPTIC/HOLDING TANK
Date Installed /0/~ '~ /~0¢
_ Size No. of Compartments
Standpipes (Y/N) ~"~"¢ Air-tight Caps (Y/N) /Ye--< Foundation Cleanout
Depression over Tank (Y/N) /"~¢ Date Last Pumped
Pumping/Maintenance Contract on File (Y/N) ,///,~ ;for
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
TO Water-Supply Well 77~-"¢'
Temporary Holding Tank Permit (Y/N)
To Building Foundation
To Property Line __ .:
To Water Main/Service Line
To Disposal Field
To Stream, Pond, Lake, or Major Drainage
Course
Comments
Page 1 of 2
72-026(lf/84~
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed _
Width of Field
Square Feet of Absorption Area
Depression over Field (Y/N)
Resells of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well -.~ /
To Building Foundation ~"~-
Lot
Type of System Design'~-'~ 'J-~u:¢'~'~f":'--
Length of Field .~
Depth of Field ~/~¢~ '~
Gravel Bed Thickness ~/~ ~
Standpipes Present (Y/N) ~
Date of Last Adequacy Test ~/¢/~ ~
/
To Property Line __
To Existing or Abandoned System on
; On Adjoining Lots ,,~
To Water Main/Service Line
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
TO Cutbank (if present) ,'~,,~
LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
, ,~ ,'.~?¢¢'¢,'o,"- ,,',~o~,.--h O,_f ,~. P,--,~'7'~. 4~.r,-~'.,I W~p~.,., I,'~e~.lV
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have check¢~, veer conformed to all MOA a~d HAA g uideli nes in effect on the date of this inspection.
Company~~~'~'~ ~'~ ~ MOA No.
Receipt No. ~0~{ -DOt '.%
Date of Payment ~ -(0'%~
~ ~." k'~ ~ ·
Amount: $ ~)~ ~ : ~T % ~ ~ Engineer s Seal
~ k No. ¢~-E ].~
P. c~/o x l~aa~o
ANCHOF]AGE, ALASKA 99519-6650
(907) 264-x'!Jd~× 4744
TONY I(NOWI ES.
MA YOt?
DEPAR'Ff~ENT OF I'I, EALT[I & [IUI~IAN .SERVICES
August 13, 1986
Stan Brust,
1610 Dimond Drive
Anchorage, Alaska 99507
Subject: Lot 10 Block 3 Sun~it Estates Subdivision
Waiver Request, WR86-115
Dear Mr~ Brust:
Your request for a waiver of the 100 foot separation distance required
between the septic tank and well on the subject property has been granted°
This distance has been waived to 95 feet.
This waiver is valid for the existing three bedroom single family dwelling
only.
Sincerely~
Stephen S. Morris
Civil Engineer
On-site Services
SSM/ljw
APPLICi~ .~T FILLS OUT UPPER HALt )NLY
...... Phone ~..C-'-~ ~
Address Zip Code
Type of Resi~nce
~ Multiple Famgy NO. of Bedroo~_ ~'~..~
Water Supply
Year Individual Installed:
~ Holding Tank
NOTE; THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSlNG CAN BE INITIATED.
Time Time Time Time
Date Date Date Date /~
Field Notes:
RECEIVED.
( ,~LAPPROVED BEDROOMS *CONDITIONS OF APPROVAL
( ) DISAPPROVED
( ) CONDITIONAL APPROVAL'
Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received /~,-.,.~
"~ ~:~ Well to Tank Septic Tank Size ~,/~
October 18, 1983
John A. Treptow
420 "L" Street, Suite 500
Anchorage, AK 99501
:~ubject: Lot 10 t~lock 3 Summit Estates
Approval for the individual sewer an(] water facilities cannot
be granted until the follo%,~in{j items have been com~)leted.
°/~'he top of the well casing should be sealed so that it is
~ f %~ater tight.
//Exposed electrical wires to the well head are in violation
~/~_.~f'the ~unicipality of AnChorage codes and must be encased
in conduit.
The septic tank pumped ;;ith a receipt submitted to this
department 0
An adequacy test needs to be performed on the existing
leaching area. This test will determine if the syste~n is
adequate according to National Standards° A listing of
private firms performing the test is enclosed. This report
needs to be submitted to this office for our review.
Please notify this Department for a reinspection ~,;hen the
noted discrepancies have been corrected. If there are any
further questions, please call this office at 264-4720.
olncerely,
Ja88/p/E~{
Enclosure
c c: Benson
W~ndy Chapman
555 W. Northern Lights
Anchorage, AK
Jim Roberts;
Associate Environmental Specialist
STANLEY BRUST & ASSOC]IATES
En,~ineers - Planners - Surre)'ors
Project No.
Adequacy Test'Log
Date Time Level Readings Remarks
septic tank
STANLEY BRUST & ASSOCIATES
Engineers. Planners - Surveyor~
1.:.17 Eas! 74th Axcnu¢
Ancho;a~e, Alaska 99q07
(907) 349-6577
SL,,.,TIC SYSTEM
ADEQUACY REPORT
LEGAL D£SCRIPTION '
TYPE OF EYSTEh' ' [] SEPTIC TANK - SIZE ~//'9 ~ ~)_. Gt,[ LONS
CRIB OP, SEEPAGE PIT
LEACH FIELD
SEPTIC TANK WAS PUMPED [] YES [] NO
I unlclpali y
, ANCHORAGE, ALASKA 99502-0650
OW (907) 264-4111
Anchorage To.
,'~ /y P7.'29
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION , ~
October 18, 1983 A .... : - , ,,,..
John A. Treptow
420 "L" Street, Suite 500
Anchorage, AK 99501
Subject: Lot 10 Block 3 Summit Estates
· \ Approval for the individual sewer and water facilities cannot
') '1 be granted until the following items have been completed:
¢~ ~ [/ o The top of the well casing should be sealed so that it is
,~ ~ ~ water tight.
^~ ~o Exposed electrical wires to the Well head are in violation
~ ~ of the Municipality of Anchorage codes and must be encased
~ in conduit.
o The septic tank pumped with a receipt submitted to this
department.
An adequacy test needs to be performed on the existing
leaching area. This test will determine if the system is
adequate according to National Standards. A listing of
private firms performing the test is enclosed. This report
needs to be submitted to this office for our review.
Please notify this Department for a reinspection when the
noted discrepancies have been corrected. If there are any
further questions, please call this office at 264-4720.
Sincerely,
,//~im Roberts
Associate Environmental Specialist
JR88/p/EH
Enclosure
cc: .Benson
Wendy Chapman
555 W. Northern Lights
Anchorage, AK
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI ON
825 L Street - Anchorage, Alaska 99501
ENVIRONMENTAL ENGINEERING DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1, Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTY OWNER
MariamWallwin
PHONE
?
MAILING ADDRESS
5~55 Summit Street, Anchorage, Alaska 99504
PROPERTY RESIDENT {If different from abovet
SEL~e
2, BUYER
John A. Treptow
PHONE
PHONE
274-6759
MAILING ADDRESS
809 E. llth, Anchorage, Alaska
3, LENDING INSTITUTION
Coast Mortgage Company
MAI LING ADDR ESS
P.O. Box 12007 Anchorage, Alaska 99510
4. REALTOR/AGENT
Skell Area Re~l~ors
IPHONE
279-0665
IPHONE
278~2525
MAI LING AD DR ESS
5. LEGAL DESCRIPTION
Lot 10. Block B, Summit Estates Subd.
STREET LOCATION
~4~ Summit'Street
6. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] One [~ Four [] Other
[] SINGLE FAMILY
[] Two [] Five
[] MULTIPLE FAMILY [] Three [] Six
7. WATER SUPPLY
[] INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
[] COMMUNITY since June 1975. For wells drilled prior to that date, give well
[] PUBLIC UTILITY depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
[] INDIVIDUAL/ON-SITE**
[] PUBLIC UTILITY
**If individual/on-site, give installation date
If system is over two (2) years old an adequacy test is required
by this Department,
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED,
72-010(3/78)
~ · MUNICIPALITY OF ANCHORAGF~
/~-~'~ DEPARTML_~' OF HEALTH AND ENVIRONMEN, L PROTECTION
i~'~]] ' ' 825-.L Street, Anchorage, Alask'--'a 99501
./ // /~ . Date Received: May 27 1977
#1: Time 9:30 a.m. 92: Time #3: Time
Date 6-1-77 Wed. Date Date
Insp Kennedy Insp Insp
?
REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES
Lending Institution Request: Alaska Statebank
Mailing Address: 310 East Northern Lights Blvd. Phone: 279-7637
2. Property Owner: Donald H. Dahl Phone: 344-5720
Mailing Address: Star Route A Box 78A 99507
Legal DescrSption: Lot 10 Block 3 Summit Estates
Single Family Residence: (x) Number of Bedrooms: 2
Multiple Family Residence: ( ) Number of Bedrooms:
5. Well System:
Permit #
Construction
,
6. Sewage Disposal System:
Permit #
Septic Tank Size
Absorpt'ion Area
e
Individual well (x) Community/Public System ( )
Depth of Well 302' Well Log on File
Bacterial Analysis
On-site System ~x~ Public
InstAlled 1976 Installer
Manufacturer
Soils Rate Material
Utility ( )
( )
Distances: Well to Septic Tank to Absorption Area
to Sewer Line Nearest Lot line Absorption Area
to Nearest Lot Line
Department of Health and Environmental Protection
Request for Approval of Individual Sewer and Water Facilities
Legal Description: Lot 10 Block 3 Summitt Estates
Comments:
.Affada~( )
Letter Attached: ( )
Date:
Department Worksheet:
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspection: CMRO VA FHA
2. Property Owner: ~ a w_
Mailing Address:~?S~ Box 78 A, Anohore~;e~ A~.
3. Name of Buyer: David Lo~ze
Mailing Address: 91st Ave° ~ ~chorec;e,
4. Name of Lending Institution: Alaska Statebez~
Mailing Address: ~lO E. Northe~z Lights Blvd.
5. Name of Realtor or Agent:
Mailing Address:~ Phone:
6. Legal Description:
Lot 10, Blk. % Summit Estates
Day Phone:
Day Phone:
Phone: 279-76~7
CONV
344-5720
3~-7oo9
Location:
Type of Facility to be Inspected:
Water Supply
Type of Supply: Public Utility
If Individual, number of dwellings presently served
No. Bdrms. 2
If Individual, depth of well 302
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation 1976
Individual X
1
X
Single Fam, Res,
Individual (on-site)
72 003(3/76)
#1: Time
Date
Insp
MUNICIPALITY OF ANCHORAGE
' DEPARTMENL~/OF HEALTH AND ENVIRONMENTk_~PROTECTION
825 L Street, Anchorage, Alaska -99501
279-2511, ext. 224 or 225
Date Received: April 19, 1977
1:30 pm. #2: Time #3: Time
4-20-77 Wed. Date Date
RCPratt Insp Insp
REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES
Lending Institution Request: Alaska Statebank
Mailing Address: 310 East Northern Lights Blvd.
Phone:
Property Owner: Dahl Construction
Mailing Address: Star Route A Box 78 99507
Phone: 344-5720
Legal Description: Lot 10 Block 3 Summitt Estates Subdivision
Single Family Residence: (~ Number of Bedrooms: 2
Multiple Family Residence: ( ) Number of Bedrooms:
Well System:
Permit #
Construction
Public/Community System: ( ) Individual Well: (x)
Depth of Well 302' Well Log on File
Bacterial Analysis
( )
Sewage Disposal System:
Permit #
Septic Tank Size
Absorption Area
On-site System ~x) Public Utility
Installed 1976 Installer
Manufacturer
Soils Rate Material
( )
Distances: Well to Septic Tank to Absorption Area
to Sewer Line Nearest Lot line Absorption Area
to Nearest Lot Line
,Page, Two- k~/
Department of Health and Environmental Protection
Request for Approval of Individual Sewer and Water Facilities
Leqal Description: Lot 10 Block 3 Summit Estates
Comments:
Affadavit Attached: ( )
Approved:
Disapproved:
Letter Attached: (
Date:
Date:
Department Worksheet:
I · M'UNICIPALITY OF ANCHORAG~
~rotec ~ PALiT,F~O,:
/~'~k<x I Departmen~of Health and Envlronmen~ '
.- . -
· //--~ / .,- - o9~ L Stree~ :~chorage, Alask
~ '-;~i(;~ ?/ 279-2511, ext. 224, 225
~'~;'? ~ -- ~ ~r~xral Oe Individual Sewer and Wate~ Fac~
Narae of Buyer: _
Phone:
Mailing Address: '-
Realtor/Agent:
Phone:
Mailing Address:
Street Locatmon:
Single Family Resi'dence:
Multiple Family Residence: ( ) Number of Bedrooms:
7 o
Water Supply: * individual Well ~ Public/Con%reunify System ( )
If Individual Well, well depth ~_~ ~
If Community System, name of system
Sewage Disposal System: On-site System ~ Public System
If On-site System, date of installation: ~ ~
( )
*' TE A well ]_og is required on kLL wells drilled since 6/75.
NO. :
3/77