Loading...
HomeMy WebLinkAboutSKYLINE VIEW BLK 1 LT 28kyl ine View lock I Lot 28 051 - 192 -27 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: osP1011~,¢ I PID Number: o514111~1~ Name: Lester and Susan Scheunemann Wastewater System: [] New [] Upgrade Address: P.O. Box 670744 Chugiak, AK ABSORPTION FIELD Phone: Number of Bedrooms: 3 [] DeepTrench [] Shallow Trench [] Bed [] Mound [] Other: LEGAL DESCRIPTION soil Rating: Total Depth from odginal grade: GPD/Ft~ Ft. Block: 1 Lot: 28 Subdivision:~-:~,,e~""ne View Depth to pipe bottom from odginal grade: Gravel depth beneath pipe: Ft. Ft. Township: Range: Section: Fill added above odginal grade: Gravel Length: Ft. Ft. Well: [] New [] Upgrade Gravel width: Ft. Number of lines: Distance between lines:Ft, Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: ~-x~sung Ft. Ft. Ft2 Ddller: Date Ddlled: Static Water Level: Installer: Date Installed: Ft. Stuart Gilbert 8/19/10 Yield: GPM Pump Set at: Ft. Casing Height Above Ground: Ft. TAN K SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~ Septic Absorption Lift Holding )ubl[c/Private Manufacturer: Capacity: Tank Field Station Tank Sewer Line Anchorage Tank 1000 Material: Number of Compartments: Well 80 .... >100' N/A N/A >25' Steel Two (2) Surface WaterLot Line>5'>100' >100'>10' N/AN/A N/AN/A ~ Size: Gal. Manufacturer:LIFT STATION "Pump on" level at: "Pump oft" level at: in. High water alarm at: Foundation >5' > 10' N/A N/A in. in, Curtain Drain None Noted Pump Make & Model Electrical Inspections performed by: Remarks: Existing Septic Tank Pumped, Crushed and Backfilled. BENCH MARK Location and Description: Septic Tank Only and Two Post Tank Cleanouts Placed Rear Deck Southwest Corner. Assumed Elevation: Under this Permit. Ft. ***See Waiver to Adjacent Wells. Inspections performed by: U. Anderson Dates: 1st 8/19/10 2nd 8/19/10 Development Services Department Approval Conditional Approval Date: I ~,00, LO.O0 N 0 0 ,~B'LO I. M,,O0, LO.O0 N '""1 133~1S aooMooa C Z . Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 995'19-6655 - 343~7904 OmSite Wastewater Disposal System or Well h3spection Report Permit Number: OSP101138 Page 3 of 3 No. 05! -I 11-59 Tank Only Repiaced Under This Permit. Existing Tank Pumped, Crushed and Backfilled on Site. PROFILE AS-BUILT No Scale Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System OSP101141 05119227000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: August 10, 2010 to Design Engineer: ANDERSON ENGINEERING Subdivision: SKYLINE VIEW Site Legal Address: SKYLINE VIEW BLK 1 LT Own er/Add ress: August10,2011 28 G:1159 SCHEUNEMANN LESTERW& SUSAN B PO BOX 670744 CHUGIAK AK 995670744 Site Mailing Address: 19376 DOGWOOD ST, Chugiak Permit Lot Size in Sq Ft: 16050 Total Bedrooms: 3 [.) (;l) a r t m e ~ t This permit is for the construction of: N Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: Municipality of Anchorage ONSITE WATER & WASTEWATER PROGRAM CHANGE ORDER PERMIT # SP101t'Li"I PID No' 051-192-27 SUBD SkylJne View TRACT BLOCK i LOT 28 CONTACT PERSON Michael E. Anderson, P.E. PHONE 522-7773 FAX 677-7766 PLEASE GIVE A DESCRIPTION OF THE CHANGE: Only :1.2" of drop exists between the existing foundation cleanout and the distribution line of the absorption trench on this lot. It is not possible to place the new septic tank outside the protective radii of the wells on Lots 9 and :LO of Tundra ]ewel Ranch Subdivision to the north of this lot. We have therefore moved the septic tank to the north side of the trench and outside the :LO0' protective radius of the well on this lot, but closer to the well on Lot :LO to avoid the contaminated area of the existing septic tank. A request to reduce the separation distance to the well on Lot :LO is attached. We request a quick review to allow replacement of the tank which is leaking excessively at this time. on:site Revie~~ APPROVED(date) Comments Issued (date) Review Time (hours) HOURLY RATE TOTAL TO BE PA_rD DATE PA_rD $130 RECEZPT # Municip=ali=ty o[ A___nc~ho___rage P.O. Box 196650 4700 Elmore Road Anchora~qe, Alaska 99519-6650 ® (907) 343-7904 · Fax (907) 343-7997 http :llwww.muni.or,qlOnsite Development Services Department On-Site Water and Wastewater Proqram **** VARIANCE/WAIVER REVIEW **** WR#: OSX101003 HA#: PID#: 051-192-27 Legal Description: Skyline View B1 L28 Engineer: Anderson Enqineerinfl Permit: OSP101141 Applicant: Lester Scheunemann Your request for a waiver of the required 1 O0 feet horizontal separation from the septic tank to the private well has been approved., e approved ovx '-Ftx~ -d~ ~o~ ~ ~ro~cl~ L¢~t/T~, separation distance is 80.0 feet.-[0 -~x~ ~d~ I'l This waiver approval applies to the existing septic tank to private well separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm Waiver is Granted: X Waiver is not Granted: Rec~: 062160 Amount: $1,050.00 Date Paid: 8118110 **** VARIANCE/WAIVER REVIEW **** Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www. muni.org/onsite (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-192-27 Property owner(s). Lester and Susan Scheunemann Mailing address P.O. Box 670744 Chugiak, AK Site address 19376 Dogwood Street Chugiak, AK Day phone Zip Code 99567 Zip Code 99567 Legal description (Sub'd., Block & Lot) Lot 28, Block 1, Skyline View Subdivision Legal description (Township, Range & Section) Lot Size 16,050 Sq. Ft. Number of Bedrooms Three (3) THIS APPLICATION IS FOR ([~ all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING P,O. BOX 240773 ANCHORAGE, AK 99524 522,7773 522'6779 (FAX) August 3, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 28, Block 1, Skyline View Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The septic tank on Lot 28, Block 1, Skyline View Subdivision has failed and must be replaced. We are proposing to replace the tank with a new 1,000-gallon steel septic tank to serve the three-bedroom home on the lot. The existing absorption trench will remain in place for reuse. We are therefore requesting a permit be issued for the construction of a new septic tank on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing septic system and the location of the new tank. Also identified on the plans is the existing well on the lot and those on adjacent lots. The existing tank falls within the radii of three wells. The new tank will be placed more than 100' from the well on this lot and those in the area. The existing tank on the lot will be properly disposed on the property. The lot is virtually flat and drainage patterns will be maintained after construction. The ground surface on the lot is basically flat in the area of the new tank and in all other areas. The new septic tank will be constructed near the location of the existing tank and as parallel with the slope of the land as possible in conformance with Municipal requirements. If the tank is constructed in accordance with our design the following statements apply: The tank, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The tank, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. Lot 28, Block 1, Skyline View August 3, 2010 Page 2 of 2 The tank, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The tank, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 18, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Attention: On Site Services Engineer Subject: Lot 10, Tundra Jewel Ranch Subdivision Lot 28, Block 1, Skyline View Subdeivision Separation Distance Waiver Well to Septic Tank Dear On Site Services Engineer: The well on Lot 10, Tundra Jewel Ranch Subdivision is located approximately 88' from the septic tank on Lot 28, Block 1, Skyline View Subdivision. The 100' separation distance between the well and the septic tank was waivered to 88' in March of 2003. Since that time the septic tank on Lot 28 has failed and is currently leaking and must be replaced immediately. The septic tank is currently located inside the 100' protective radius of the well on Lot 28 and will be moved outside the radius to meet current code. It must also be moved to the north to avoid contamination from the leaking tank and maintain 5' separation from the absorption trench. We are therefore requesting the waiver from the well on Lot 10 be reduced to 80' to provide sufficient room for placement of the new tank. The well on Lot 9, Tundra Jewel Ranch Subdivision currently has a waiver allowing the protective radius to be 80'. Allowing the new septic tank to be 80' from the well on Lot 10 will not increase the risk of contamination to the well. It will also allow the new septic tank on Lot 28 to conform with the 100' separation distance from the well on Lot 28. The well on Lot 10 is 262' in depth and cased to the bottom. The aquifer supplying the well is 243' below the surface and protected by a clay layer from 90' to 121' which is typically impermeable. The static water level is at 185' below the surface. Any contamination from the surface would pass through multiple layers of sand and gravel before encountering the clay layer. Water would then flow laterally along the clay layer and may never reach the aquifer. The septic tank to be installed is manufactured by Anchorage Tank to the Uniform Plumbing Code and is 5' in diameter and 10' in length. It is coated with coal tar pitch on the interior and exterior. The bottom of the tank will be approximately 9' below ground. The ground surface of the lots in the area are generally flat with a high mound of vegetation between the well and the proposed septic tank on Lot 28. An overflow of the tank or the Lot 10, Tundra Jewel Ranch Lot 28, Block 1, Skyline View August 18, 2010 Page 2 of 2 absorption trench would be away from the well. We are confident the possibility of contamination of the well on Lot 10 from the septic system on Lot 28 is slight to nonexistent. ADEC POINT ANALYSIS Bottom of Tank to Highest Water Table - 181' Soil Absorption Type - Clay and Sand Permeability - Sand and Gravel Water Table Gradient - 0% Horizontal Separation - 80' 8.00 Points 2.50 Points 1.00 Points 2.90 Points 2.50 Points TOTAL POINTS 16.9 Almost sure to be free from any form of contamination from household sewage. Attached are the well log and other drawings showing the proximity of the existing septic system to the well. We hereby request the waiver be issued and the septic tank construction permit be approved. Sincerely, Michael E. Anderson, P.E. Attachments ~ 22 25 4 7 I-- 0 u') 0 u3 0 - 24 5 6 Avenue · ..*~ ~ SKYLINE VIEW SUBDIVISION LOT 28, BLOCK 1 16,050 S.F. Existing AbsorpUonTrench 37' Long x 2.5' Wide x 6' Effective Depth Existing Wellf Existing / ~ Well / ! 150.00 /// /0' Utility Easement Pump, Crush and /! / Abandon Existing / ! / Tank in Place, / / / Place New 1,000 / / / Gallon Septic / ! / / Tank, and 2 Post 1' ~-~ / / Tank Cleanouts. ]' ~ / / · / / B /gxisting m __ //' Well // / / / -FCO /× \ X \ \ NOTE: Verify Presence ond Location of All Wells in the Area. Registered Land Surveyor to Stoke oil Well Ro~:lii. LEGEND SV - Septic Vent CO Cleon Out MT - Monitor Tube TH - Test Hole SITE PLAN SCALE 1" = 50' ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 28, BLOCK 1, SKYLINE VIEW SUBDIVISION GENERAL: The scope of this project includes the pumping, crushing and backfilling of the existing septic tank on the property and the procurement and placement of a new 1,000-gallon septic tank and two post tank cleanouts at the location shown on the Site Plan. Work also includes the placement of a foundation cleanout, if necessary and connection of the new tank into the existing absorption trench. The new septic tank must be placed as far as possible from the existing well on the lot and 100' from all private wells and any surface water in the area and 10' from the water service line from the well. A minimum of 4' of cover is required over the septic tank. The foundation cleanout must be replaced if one is not found on the property. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Development Services Department Building Safety Division On-Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On-Site Water and Wastewater Program before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000-gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 28, Block 1, Skyline View August 2, 2010 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: - EXISTING ABSORPTION TRENCH TO REMAIN IN SERVICE 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. All pockets of unacceptable materials must be removed and replaced. Lot 28, Block 1, Skyline View August 2, 2010 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. ~.. MUNICIPALITY OF ANCHORAGE  ' ~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION !~'~ ~. ,~/t ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Teleplmne 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~ PHONE J~.N EW LEGAL DESCRIPTION  Well qR 1~ Absorption area 2V7 /~ ~ Dwelling PERMIT NO, DISTANCE TO: ~<~ = Manufacturer ~2~ Material Inside length Width Liquid depth Liq. capacity in~allons //)~ IF HOMEMADE: ~ ~ ~O ~ DISTANCE TO: Well ~/ /~ Dwelling PERMIT NO, ~ ~ ~ Manufacturer/~ Material Liquid capacity in gallons ~, DISTANCE TO: Well /~ ~ Foundation ~/ ~ Nearestlotline ~__ PERMITNO. ¢~ __ ~g_ No. of lines / Length cl, lin[~)~ Total length of linet~,~¢. Trench ~d~,~j inches Distance between lines ~ ~ Top of tile to fin,Mb grade ~ Material beneath t, le 92 inches Total effect,ye absorl~¢n ~rea ~¢ ~ -- Length Width Depth PERMIT ~ Type of crib Crib diameter Crib depth Total effective absorption area u~ Well Building foundation Nearest lot line m DISTANCE TO: ~ Class~/,~/2~ ~ ~epth Driller Distance to lot ]ine PERMIT NO. ~~ Building ~oundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER r ~ /~'~-~,'.~' ........ ,,. .... ,~,~,,, . - , ,~ ~.~ / / 72-013 ,3~78) MUNICIPALITY OF ANCHORAGE Department f Health and Environmenta~ ?rotection(~ 825 ~ Street, Anchorage, AK. ~501 264-4720 * * * HANDWRITTEN PERMIT * * * WB~k_A. ND/OR=ON-SITE SEWER PERMIT Mailing Address: /70,~,~'~' 7 Lot Size: ~ Holding Tank: Location: ~-~-~--~ Phone Number: Legal Description: ~_ ~/~./ ~,~'//1~ ~/t~, Type of Soil Absorption System Is: Trench: ~ .... Drainfield: Seepage Bed: Maximum Number of Bedrooms: .~'~ Soil Rating(sq.ft/br) /~ The Required Size of the Soil Absorption System Is: DEPTH ~ LENGTH ~3 GRAVEL DEPTH ~' WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = ~[~ GALLONS * * Permit applicant has the r~sponsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the ~esidence is remodeled to include more that/ 3~droom~//~ Signe~: ~ ~F~-' Issued by: ~(~_-~)~-~/~ .~ Applicant SWP/024 (1/81) [] SOILS LOG PERFORMED FOR: LEGAL DESCRIPTION: 1 2 5 6 7 8 10 11 12 13 14 15 16 17 18 19 2O COMMENTS PERFORMED BY: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 625 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST [] PERCOLATION TEST Robert A. Shaft No. 1457-E ENCOUNTERED? O P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) 72-008 (6/79) by DOC Co, dba P.O. BOX272, CHUGIAK, ALASKA 99567 · TELEPHONE688-2759 OWNER OF LAND , . ADI)RESS LEGAL DESCRIPTION DATE - Started ' Ende(J PERMIT NUMBER DEPTIt OF WELL / O, ~', STATIC LEVEL OF WATER Fl'. DRAW DOWN FT. GALS. PER HR ," ' KIND OF CASING ~:, r:,~,,L? KIND OF FORMATION: From_ Ft. to Ft. From ____ Ft. to , , ,, Ft. From Ft. to Ft. . From Ft. to Ft. Frora.__ Ft. to. Ft. ;;rom Ft, to _Ft. ~q'om .... Ft. to___ Ft. From_ Ft. to Ft, From.__Ft. to Ft, Frorn Ft. to Ft. From____Ft. to .Ft. From____Ft. to.__Ft. From__ Ft. to .Ft From ..... Ft. to Ft From .... Ft. to__Ft. iq'om ........ Ft. to__Ft. From ..... Ft. to__ Ft. From __Ft. to-, --Ft.. From Ft. to__ .Ft.. From__Ft. to , Ft.. From Ft, to ~Ft. From Ft. to From Ft. to ..Ft. From Ft. to Ft.. From Ft. to _Ft. From__Ft. to From Ft. to_ From __ Ft. to---- From _Ft. to From Ft. to_ From Ft. to ...... From Ft. to I:rom Ft. to_ From _Ft. to_ Et, l Ft. Ft, Ft. .... Ft. _ .Ft ...... Ft.. ___Ft ...................... __Ft,.. M}SCL. INFORMATION: , ' E.... E ;.. ~~'" 'T * E:.I'.., ,* , l',lO. ":::~"I 2f"~':l ......... '" ' "~"'"""~' PI"IOI"412: , . ~, ~..*. ,' I.~['.., I'"11( '...E..q::, ,' ,' , '":~,:",' "" ~'"','"','"'~','" , .... ' '" ' -' '" '"' '" ": "' ' [31....OCt:;:; ::L I....OT; .... '"'" ......................... ....~[ I .... II .:,1...,~..,I ........ :.,.[ ...t4. E;I':::"~"LZI",IE ",.'~EE['.l ,~:.;:::' L ('. T :.,'"" .,. ~ ,~.'":'":~ ..... ~:::~ 5C. FT. 'T'OI.'.INSH :1:1:::'; .... ~:f:::lt",l(2iE: SECT Z O1',t; .... Z ..Ef I~[ IIh,, ::L. :I: i":1~'I FFtI"'I:[L.:[I::t~: t.'.I:[TII THE I:E:E~];fl...tZI:~:I2:I"IE:I',IT'.7~; FEI:;' ::i"~'"'::J't"T'IE f~EI.,.IIEt;~:S t':INE:' HIEI....I....E; F:IS SE:"I" , , ,. .... , U',' THE HIJN :1: C :1: Pt::lL ]] T ~1 O1:::' I":II'.,tCI..I(::I[~:I'::ICE I:::IND THE ?['FITE: I":I1:::' FI[1.1:'I:~]~I::]:':I. _, , =,~ ,j , ,'H,,''",l'",'',r", '",,'" ,'"r~' ' ~'r "~"~ ,, .., , '" I, ...... ,,~..., I'1 I'~ - r::'~.~' (]I1:':' "I"I'tE:,_.,...'"" ~'"'"~'~...,.:. E;I...It',II',If':iF:'.',' "~ ......... :' '~" ~'''' ' ............... r: """' , [.I..,I.t.T. .... I~ 4,.. ,..., ........ , ,1[.. TIIi::iT "I"HI]2:ON '""'" '~'~ ._,i....,...,._F.. ~, , ..:, FM, I'"11":i'~' I.;. _,:.lj .~., ..E. ,.:N~.. ~-...~ I I, ,,, TI IE ::~:. :I: ' "' ~ ~" ""' ::" " .... ,~ ,~. '-'~" '~:" '"-' '" .......... ' ""~"- ~' ~' ': " - r ........ "'~' '"".'.'~'' ~:' ,-..~_, ,uE ELL..I... TO ., ,_ .... ~ ..... ..,~.., . 1...[......, Z I.... L. h, .......... ]: '..':; '-'~"'"" ' ' [ ~..,. ......... ,,, .............~ llf::tS THE I';'.EEF'"'N":;'I:E:ZL ZT"r' "1'~ ZI'.II:',':'~'.I"I F't:]:'~"r~":f'INEL ,.. ,J ,:. :I: N Ei .... I[ ........... :, FID..:rI':'ICE:NT TO "I'H :[ E'.; - ~... Ir:If,ID THE: IL. Eli....[ ...... TIII:':IT '~ .....14[~:L.I.... I...I~[1..E .:,[..I ........ N J, 1,. ,L.,.. OF IE:E'.~; , I ~.. TI IE: ' ~' '" ,.....I., .... ,, ........, .~.:, ~.t,1.~, , L..L,.:.I.., I::IN El F:'~':'TI;;:Z _., I I::'EF~:I"'I i::IND ~I'.,ISI:::'I~CTZE:~N I"II~ST ,,, f,. ........ ~... 1...I'~"'''' ''~ -~ ......,__.,,.]:E;F'IL. .,.N ............. ]'~:11'.4 .,.,. BI::: .....I .I. I ........... i I'. ......,...:, ....... ' ~" . _ , t::t I....ZCEI',ISI~:D E.LE.L. I ,.. [ ..~111-,I I?I:'E'F'"'I:;"T'.TI'IE IEI...E:CTI:E'.ZCF:IL t..ld,..I... I'"1 I'::;T I]:',E: I::,E~I'.,IE E"r ' ......... '"' '~' MUNICIPALITY OF ANCHORAGE ~ Health and Environmenta? ,~ Department ~rotection . 825 ~ Street, Anchorage, AK. ~3501 Permit ~~-~P-( WELL ~ND/OR-ON-~-TE~R PERMIT Applicant: ~ Mailing Address: Location: Phone/Number: Type of Soil Absorption System Is: Seepag~edt Holding Trench: Drainfield: ~ ~._~ ~¢~/1 Ratin~(s~.ft/br) Tank: Maximum ~umber of Bedrooms: The Required Size ~~Absorption System Is: DEPTH LENGTH GRAVEL DEPTH WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED ~ * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are avai]Lable to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 3 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system ~ay require enlar~e~nt if the residence is remodeled to include more ~ha~ b~oms// ~ SWP/024(1/81) APPLIL,.,NT FILLS OUT UPPER HAL ONLY Phone Property Owner (. ~',., ~ \ ' . · Buyer Address Zip Code Type of Residence ~ Multiple Family No. of Bedrooms~ ~ Olher Water Supply A~ACH WELL LOG. A w~l Icg is required for all wells drilled since June 1975.  Individual Community For wells drilled prior to that date, give well depth (attach Icg if available). ~ Public Utility Sewer Disposal ~ individual Year Individual Installed:_ ~"Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date Inspector Inspector Inspector inspector AUG 1 9 1983 "~d ~c'pa~ APPROVAL ) DISAPPROVED ~ (DATEBy: )~~CONDITIONAL~PRO~ ~L:~ ¢~ ~) Soils Rating Date ~wer installed Well To Absorplion Area Well Log Received 72.023 (3182)