Loading...
HomeMy WebLinkAboutSKYWAY PARK ESTATES BLK 4 LT 7Onsite File Skyway Park Estates Block 4 Lot 7 #019-151-03 suoml 1 1 AL (Rev 05/02/18) Municipality of Anchorage AUG 0 7 202 On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201127 PID Number: 019-151-03 Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name Beverly & Clifford Ivey ABSORPTION FIELD ❑ Deep Trench ❑e Wide Trench ❑ Bed ❑ Mound Site Address 12001 Toy Dr. Anchorage, AK 99515 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 868-3159 4 5.0 GPD/SF 3.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Skyway Park Estates 4 7 Fill added above original grade 0.0 Ft. Gravel length 30 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 150 Ft2 1 Ft. Well >50' >50' >50' N/A >25' TANK El septic EJS.T.E.P. E] Holding XOther Manufacturer Capacity Orenco/Advantex FAP 1,500 Gal. Surface Water >50' >50' >50' N/A Material Fiberglass Number of compartments 2 Lot Line >5' >10' >5' N/A NA Foundation >1 0' > 1 0' >1 0' N/A LIFT STATION Manufacturer OrenCo/Asch. Tank Capacity 100 Gal. Remarks Line under driveway is insulated with 4" of insulation. Alarm location Electrical installed by Laundry room. Capstone Electric PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Installer A+ Home Services Drainfield D3034 Co/MTD3034 Inspector L. Tidwell / J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection15` 7/15/20 nd 7/16/20 Location and description dates:2 Threshold of front door. 3rd 4'h ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF 44 Conditional Approval: Date sa�P,.•••" ••:�S ®® Aff ' 9th'_®�' ® -4 ....._. . -............. v� 1XCHAEL E. ANDERSON a Septic Syste Approved Date 8 -;a,% No. No. CE -4381 ffi ZD F •..,a/s/zo ,,,>-''�� �'°ROFESS����®'4j®® �� Note: this approv;7oes not include well permit requirements. (Rev 05/02/18) SKYWAY PARK ESTATES, BLOCK 4 LOT 7 =RMIT # OSP201127 PID # 019-151-03 EXISTING SEPTIC SYSTEM DECOMMISSIONED & / \DRIVEWAY INSULATION ABANDONEDJIN PLACE. VER LINE UND R \ 1-1 /LOT 66 1 00'WELL RA IUS t4-BDRM / 5' UTILITY EASEMENT 1500 -GAL DVANTEX TANK W/ 420 POD M ( TH1 MT1 / TFA cI LOT 7 / T2 IGARA,E SHED THH2 C s EXIS�fI G WELL \ / 50' / ALTERNATE SITE X � sHE1� \ _ NOTE: NY pTHER WELL RE SHED OR FOUND N PROPERTY 30' LO x 5' WIDE x .5' EFFECTIV DEPTH BSORPTION TRENCH. I 5' FRO PROPERTY LINE) LOT 8 EXISTIN� WELL ENGI N EERI NGI I� \ � I PLAN AS -BUILT _0 Z Lu Lu U) 0 ,QR D J- 0 50 100 FEET 1 "=50' B / /C 2C0 1.5 16.8 MH1 3 .5 15.4 MH2 44.2 15.9 PV 47. 17. MT1 5 .3 —4-8'0 MT2 76.5 /52.3 LEGEND CONTOURS: 5' INTERVALS CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT PV - PUMP VAULT MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE SKYWAY PARK ESTATES, BLOCK 4 LOT 7 PERMIT # OSP201127 95.1 GE ENGINEERING PID # 019-151-03 2" INSULATION 94.6 m 97.6 ORIGINAL/FINISH GRADE DRAINFIELD ROCK 30' GROUNDWATER @ 90.6 3/6/18 89.1 (TO IMPERMEABLES) PROFILE AS -BUILT (NO SCALE) Eve 95.1 C r►_ 0- =40' =40' I 30 P-632 SKYWAY PARK ESTATES LOT 7, BLOCK 4 67,108 S.F. AS -BU I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, ?000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. SW2729 8/10/2020 ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. NOTE: NO CORNERS SET THIS DATE 06-02 1 SPE74 0 N W 0 0 0 0 0 0 0 OF 14# i * :• 49TH �.. .........9000........ /.. .. 9999 ...........� :. Jeffery A. Gastaldi : o LS -6091 : � 8/10/2020 : a� • • • mPa�•......9'°�•a SJI. p rOfessiona\ ••\-a� •1`�1 YA1•• 1R'v .- BUILDING DETAIL SCALE: 1 "=20' MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: .(907) 343=7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System"Permit Permit Number: OSP201127 Work Type: Septic Upgrade Tax Code Number: 01915103000 Site Legal Address: SKYWAY PARK ESTATES BLK 4 LT 7 G:2729 Site Mailing Address: 12001 TOY DR, Anchorage Owner: IVEY BEVERLY Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq; Ft: Total Bedrooms: 5 `1r Department 6/5/2020 6/5/2021 67594 0 Disposal Field P Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72),and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation_ The engineer shall notify the Development Services Departmentl per AMC 1.5.65. Provide notification by calling. (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during; freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 4pecial Provisions: 1. The Engineer is to do an additional test hole prior to the construction of the s e4d-C- enstniction-may- t., proceed at your own risk before the 7 day water monitorin is e. lease submit stamped and signed if"results with the As -built Inspection Report. If th require a design change, construction of the system will stop pending On -Site review and 9p rev �2. The mound is t have it and be seeded right after construction in order to quickly establish vegetation. 716/Zo Chun ,-,erd6v • DeS,' ��+n f, -6eea Oil nein -I0L ho)e_' Received By: (11111;'21z4�4 !"�/ ��.�/ Date: 1 Issued By: Date: 4 l��l�UMUPAUTY OF QIMC HO R 2 OE �l?Y Community Development Department `�- - Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 019-151-03 Property owner(s) Beverly & Clifford Ivey Mailing address 12001 Toy Dr. Anchorage, AK 99515 Site address Same Day phone 868-3159 Legal description (Sub'd., Block & Lot) Skyway Park Estates, Block 4 lot 7 Legal description (Township, Range & Section) Lot Size 67,594 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade R pg Duplex ElHolding (D) Tank ❑ Renewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: JR5 1 il�t 6'ZS Date of Payment: Receipt Number: Permit No. Permit App__- : .:..mac Waiver Fees: Date of Payment: Receipt Number: Waiver No. PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 16, 2020 MOA Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Subject: Skyway Park Estates, Block 4, Lot 7 – 12001 Toy Drive Septic System Design Dear On-Site Services Engineer: The owners of the above lot intend to sell their property and the existing septic system on the lot is undocumented and within the 100’ well radius. We are submitting this design and permit application for the construction of a new septic system. The attached site plan identifies the location of the home and the existing well, existing septic location and the proposed system and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The new system is designed based on a test hole recently placed on the lot. This test hole indicated groundwater at 7’ below the surface. The percolation rate of the underlying soils was determined to be less than 1 minute per inch. A soils analysis indicated the accepting soil is classified as a sand. The ground surface on the lot slopes gradually to the west at no more than 10%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Ground surface contours are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new Category III system will be a minimum of 50’ from all wells and surface water, and more than 5’ away from the property line. Please refer to the attached test hole logs, plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 7/16/20 // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // 100500 FEET 1"=50' 30' LONG x 5' WIDE x .5' EFFECTIVE DEPTH ABSORPTION TRENCH. (MIN. 5' FROM PROPERTY LINE) 1500-GAL ADVANTEX TANK W/ AX20 POD NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CONTOURS: 5' INTERVALS CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2CO MT TH1 SKYWAY PARK ESTATES, BLOCK 4 LOT 7 TOY DRIVE7/15/20 5' UTILITY EASEMENT 10' UTILITY EASEMENTSHED SHED SHED 4-BDRM HOME GARAGE TH2 PUMP VAULT MT ALTERNATE SITE EXISTING WELL DECOMMISSION EXISTING SEPTIC SYSTEM PER MOA CODE. (EXACT LOCATION & ORIENTATION OF TRENCH UNKNOWN) 50' 100' EXISTING WELL 100' WELL RADIUS 9085 95NOTE: NO OTHER WELL RECORDED OR FOUND ON PROPERTY. 2" INSULATION OVER LINE UNDER DRIVEWAY TH3 SKYWAY PARK ESTATES, BLOCK 4, LOT 7 DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 5.0 GPD/SF 5'-WIDE SHALLOW TRENCH SYSTEM 1500-GAL F.A.P. TANK w/AX- 20 POD PUMP VAULT TYPICAL TRENCH SECTION (NO SCALE) 1" PERFORATED PVC (HOLES DOWN) 30-3/16" DIAMETER HOLES @ 1' SPACING DRAINFIELD ROCK 5' NOTES: 1.GRADE AREA OVER TRENCH TO DRAIN AWAY 2.PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3.CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY TOP OF TRENCH: 6" ABOVE GRADE FLOW LINE ELEVATION:2.5' BELOW GRADE BOTTOM OF TRENCH: 3.0' BELOW GRADE 600 GPD / 5.0 GPD/SF /5' WIDE = 30 LF TRENCH REQUIRED (30 LF SPECIFIED) 7/15/20 6" 6" 6" 2" INSULATION & GEOTEXTILE FABRIC ORIGINAL GROUND 2' LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 3 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME(minutes)NET TIME(minutes) DEPTH toWATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) SKYWAY PARK ESTATES B4 L7 7/8/20 L. TIDWELL DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?9.5 0.2 6 3 4 019-151-03 BEVERLY & CLIFFORD IVEY 11:47 7/8 1 2 3 4 5 6 3 0 16 / 9 0 16 11:52 11:54 11:55 11:57 12:01 1' OB Professional Engineers Stamp: 7/15/20 <1 min yes 7.0 7/14/20 SP/SW GRAVELY SAND CL SILTY CLAY 3 0 16 / 9 0 16 3 0 16 / 9 0 16 3 0 16 / 9 0 16 3 0 16 / 9 0 16 3 0 16 / 9 0 16 6 0 16 6 0 16 6 0 16 6 0 16 6 0 16 6 0 16 <1 min <1 min <1 min <1 min <1 min PROJECT CLIENT:% GRAVEL 30.4 USCS SP PROJECT NAME:% SAND 67.9 USACOE FC N/A PROJECT NO.:% SILT/CLAY 1.7 % PASS. 0.02 mm N/A SAMPLE LOC.:% MOIST. CONTENT 6.1 % PASS. 0.002 mm N/A NUMBER/ DEPTH:UNIFORMITY COEFFICIENT (Cu) DESCRIPTION:COEFFICIENT OF GRADATION (Cc) DATE RECEIVED:ASTM D1557 (uncorrected)N/A TESTED BY:ASTM D4718 (corrected)N/A REVIEWED BY:OPTIMUM MOIST. CONTENT. (corrected)N/A SIEVE SIEVE TOTAL %SPECIFICATION SIZE (mm)SIZE (U.S.)PASSING (% PASSING) 152.40 6" 76.20 3"100 38.10 1.5"98 19.00 3/4"88 12.70 1/2"81 9.50 3/8"77 4.75 #4 70 2.00 #10 60 0.85 #20 35 0.43 #40 11 0.25 #60 3 0.15 #100 2 0.075 #200 1.7 ELAPSED DIAMETER TIME (MIN) (mm) 0 0.5 1 2 4 8 15 30 60 250 1440 HYDRAULIC COND. (ASTM D2434) DEGRADATION (ATM T-313) PLASTICITY INDEX ASTM 4318 PASSING The testing services reported herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required, NGE-TFT will provide upon written request. 11301 Olive Lane ∙ Anchorage, Alaska 99515 ∙ Phone: 907-344-5934 ∙ Fax: 907-344-5993 ∙ www.nge-tft.com N/A N/A 4.9 0.7 Forge Engineering HYDROMETER RESULT N/A SIEVE ANALYSIS RESULT Skyway 5665-20 Block 4/ Lot 7 20-S-1 Poorly-graded sand w/ gravel 7/10/2020 JA RJPC TOTAL % 115 120 125 130 135 140 145 0 2 4 6 8 10 12 14 16DRY DENSITY (pcf)MOISTURE CONTENT (%) MOISTURE-DENSITY RELATIONSHIP ASTM D1557 SILT or CLAYCOBBLES GRAVEL Coarse Fine SAND Coarse Medium Fine 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.1110100FINER BY MASS (%)GRAIN SIZE (mm) PARTICLE SIZE ANALYSIS ASTM D422 / C136 #200#40#101.5 1/2363/4 #4 #20 #60 #1003/8 U.S.SIEVE OPENING IN INCHES U.S.SIEVE NUMBERS HYDROMETER Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201127, Deb Wockenfuss, 06/05/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201127, Deb Wockenfuss, 06/05/20 1 Y OFANCHORACE A I N I i- i L, WN1 i civil: 1 N i C! n It 1v Advantex Waste Water Treatment System V': V, 1 1 1: 1 ( )\1 N F'. R : < ! \ i 1 1. 1 i \ i A � i"'. \ i ) J I 'I ) 1 (1 AL D! S I R adb We - Notary Publir ROMALD DAVID &ate of Almlm �� � Dii F 0 R, A LAS KA My Comvnmlmn Expires 0--L i, 20?1 I 1"N' - !CI P:\LITY: ilk -, 0 181 _i 0 =40' I 30 P-632 SKYWAY PARK ESTATES LOT 7, BLOCK 4 67,108 S.F. NOTE: LIMITS OF A.C. PAVING SHOWN ARE APPROXIMATE DUE TO SNOW COVER AT THE TIME OF THIS SERVICE. AS -BU I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE F•P• CANT 0 PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, ?000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR O ESTABLISHING BOUNDARY OR FENCE LINES. SW2729 4/16/2020 Z COVERED5p•0. PORCH �n d ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. DECK NOTE: NO CORNERS SET THIS DATE 06-02 1 SPE74 4 AIF CO49TH 0000 .........0.0..00....../ /... .. 0000 ..........� c Jeffery A. Gastaldi : o LS -6091 : AIF m� '. 4/16/2020 •• NPap ��•... H.�°'•a SJI.40 rOfessiono\ \-o� YA BUILDING DETAIL SCALE: 1 "=20' 1.8'X 4.5' COVE RED PORCH F•P• CANT 0 0 34.5' 0 d U Zow 11.0' O N O O 6.5 N o ;o W N Q U _ O Z U O O O N O 12.0• Z COVERED5p•0. PORCH �n d COVERED DECK 4 AIF CO49TH 0000 .........0.0..00....../ /... .. 0000 ..........� c Jeffery A. Gastaldi : o LS -6091 : AIF m� '. 4/16/2020 •• NPap ��•... H.�°'•a SJI.40 rOfessiono\ \-o� YA BUILDING DETAIL SCALE: 1 "=20' M -W DRILUNG, Inc. 85-226 P.O. Box 1IM78 9 10= O(d Saward Highway &-. (907) 34M535 ANCHORAGE. ALASKA 99511 DRIIIING LOO Wall Owner 4.or&ne Stuart- _UseofWtll DQUAtIC Location (address of: Township, Range, Section, if known; or distance main road V. B4 Skyway Park Estates Size of caslng-�A�pth of Holp 262- eet feet Static water level 40 fL ow) land surface. F inish of well (check one) open end X Screen Perforated I 's Describe screen or pe Well pumping test at -gella�, 694 (minute) for.;-�hours wl 'of drawdown from sta 7/1 Datd of completion WELL LOO Npth in feet from ground surface 4�jb'rmatlons penetrated, size of material, color and hardness 0 2 TO - 2 5 38 38 41 &V Idet -To----:- 41_TO 64 _T0_21 V� ',.4'CW 71 To 9 99 t TO_L50 7 150 3 utritacer'UtAi4it .1�0_158 158 To. 165 Gra vely Hard Pan 165 T0_.L99 Gravely clay Va 199 256 Gravely Hard Pan —TO - 256 262 Water Gravel IF -TQ— NWWA Co c -TO— cuuma-te No'M. FRTV�3 -TO- 2 -STATE G*":'ATER ANCHORAGE AREA BORO~'~H HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 N? 437 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: MAILING .. . ->. :7 .~ · ~,~,- .ADDRESS,~A~(P,,~' / :'/-~ PHONE DISTANCE FROM WELT ~/'~'- ~ LIQUID CAPACITY ..-~.--~ d~-d) __MATERIAl GALLONS. INSIDE LENGTH. NUMBER OF _COMPARTMENTS INSIDE WIDTH r~: LIQUID DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL NEAREST LOT LINE OUTSIDE DIAMETER ? Z--" OR WIDTH //(~/~ , LENGTH_ //~"' DEPTH DISTANCE FROM WELL .~.~*" TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) BUILDING FOUNDATION ~/2 ,/7~ "~' d? c~'2' SQ. ET. TILE DRAIN FIELD: DISTANCE FROM WELl ../ _, FOUNDATIONX~NEAREST LOT LINE NUMBER OF LI~ SE~ DISTANCE BETWEEN LINES ~, TRENCH WIDTH ABSo~TdAREA SQ. FT. LENGTH OF EACH LINE DEdH: TOP OF TILE TO FINISH GRADE _DEPTH OF FILTER MAI'ERIAL BENEATH TILE TOTAL LENGTH , OF LINES ./~IN. TOTAL EFFECTIVE IN. ABOVE TILE WELL: .' . '-.~-~ -, ..~:..: DISTANCE FROM -'~.:~-:,'~'~'/': WATER TYPE~/~-..~'//~z~'~- DEPTH , BUILDING FOUNDATION../_~Z~___SAMPLE_ /~/~? ., NEAREST NEAREST ,,:/SEPTIC / SEEPAGE ./ /.~ OTHER LOT LINE ~'/(~ / pz_. , SEWER LINE ,TANK. ~ ., SYSTEM ~ CESSPOOL , SOURCES DISTANCES: ,9. ./~ ~ ~- DIAGRAM O1= SYSTEM H EALffl AUTHORIIY GAAB-H D-2 "~OROUGH Cas~ N o..-~,C~~ GREATEr ANCHORAGE AREA ItEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-25111 SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT NAME OF APPLICANT ~-~v,) RESIDENCE ADDRESS, LEGAL DESCRIPTION__ APPLICATION TO INSTALL: SEPTIC TANK TO SERVE THE FOLLOWING FACILITY MAILING ADORESS.~i~d),~ '<" '~ __ LOCATION OF INSTA_LATION. SEEPAGE PIT. PHONE NO.. ,ORAIN FIELO , OTHE~ FINANCED THROUGH '~')¢? n ¢~ t TO BE INSTALLED BY .~.'!~ '~Z!~ PERCOLATION TEST R~SULTS I~)-¢"J~/ /~,^~ ANTICIPATED DATE OF COMPLETION. f'l~-- ~-~ ,~.,/'-- BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS ~ ~(. t' '-" / . , ,:'~c 0~5 ,/:,~_, PERMI r ro INSTALL A __ ,,~-(~A,~'t-¢ ASDESCRIBEO BELOW. SIZE OF UNIT TO BE SERVEl:)__. ,~-' · SEPTIC TANK SIZE /,.~"~h2/__:) TYPE ,0 ~/~C' Z. SEEPAGE AREA__~¢~ - DIAORAM OF SYSTEM DIS'rANCES: /) ,, J I certify tha~ I am familiar with the requkements of Greater Anchorage Area Borough Ordh~ance No. 28-68 and that the above described system is in accordance with said code. -/ GATE MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 t - Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 019-151-03 1. GENERAL INFORMATION Expiration Date: �)_et L{ , Q C)2 6 Complete legal description Skyway Park Estates, Block 4, Lot 7 Location (site address) 12001 Toy Drive Anchorage, AK Current property owner(s) Beverly Ivey Day phone (907) 360-0572 Mailing address Real estate agent 12001 Toy Drive, Anchorage, AK 99515 2. TYPE OF DWELLING: ❑■ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑■ Private Septic ❑K Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 2.10 CO U j 1�2 Date of Payment " `� ��' z 0 Receipt Number' �'' COSA# Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 8/22/2020 6. DSDSIGNATURE V// System #1 Approved for r bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: ��l�c�tttttirtr��r A G F � v CO 1 CyIB : Original Certificate Date: U The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Skyway Park Estates, Block 4, Lot 7 If more than 1 septic system on lot: COSA Checklist # 1 of 1 A. WELL DATA ❑■ Well log is filed with Onsite (or attached) Date drilled 7/30/85 Total depth 262 ft Cased to 262 ft X Sanitary seal is functioning correctly FE -1 Wires are properly protected Casing height (above ground) >18 in. Date of flow test for COSA 7/28/20 Static water level at beginning of test 36 ft. Comments B. TANK DATA Age of tank(s) 11 years Tank type/material F.A.P./Fiberglass Measured operating fluid level in septic tank New 9 Standpipes/foundation cleanout per record drawing Date of pumping New Construction 7/15/20. D. ABSORPTION FIELD DATA 5' Wide Trench Which system tested (date installed) 7/16120 0 ALL standpipes present per record drawing Total measured depth from grade 3.0 ft (max) Measured depth to pipe invert from grade ft (min) X N/A — pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective 1 Code -required soil cover over field System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced NA gallons Comments/Deficiencies: COSA Checklist yellow sheet 151-03 Parcel ID: 019 - Structure served by this system 1 Well production at time of test 1.3 gpm Water storage tank volume None gallons Well disinfected for coliform test? ❑ Yes No n Coliform bacteria is Negative Nitrate mg/L FUI Nitrate less than MRL (ND) Arsenic ug/L 0 Arsenic less than MRL (ND) Collected by FORGE ENGINEERING Date of Sample 8/13/20 C. LIFT STATION Q Required maintenance completed Age of lift station <1 years Lift station material PVC Comments: New Construction 7/15/20 Adequacy test date New System Results [J Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min Final fluid depth in Absorption rate gpd Any rejuvenation treatment (past 12 months) None If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100'Community ✓v Yes if No Sewer Manhole/Cleanout > 100' Yes if No>0 ft E] Yes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' ✓� Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No >50 ft Holding Tank > 100' ❑ Yes if No NSA ft Neighboring Absorption Fields > 100' Surface Water > 100' ❑ Yes Animal Containment > 50' ®✓ Yes if No ft P1 Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' F/ Yes if No ft ❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' E Yes if No ft Surface Water > 100' ❑ Yes if No >50 ft Property Line > 5' ✓v Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' ❑✓ Yes if No ft Community Wells > 200' 0✓ Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' C]✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' Yes if No Water Service Line > 10' Yes if No ft Community Wells > 200' Q✓ Yes if No Surface Water > 100' ❑ Yes if No >50 ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet Ig ft . MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR. AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of J,"V M R.r of 20_2O, by and between hgrein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Advantex Waste Water Treatment System located at (legal description) Skyway Park Estates Block 4 Lot 7 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) rVg Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in satisfactory condition capable of performing as designed and producing.treated septic effluent in accordance with the equipment's approval for operation in the Municipality. jjL SL It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). L 55 Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Uz?— Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement.' (rev. 05/18/2018) Pagel of3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWVYTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. 'per Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Zzp Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the ANVWTS approval. 3. Term. The term of this Agreement -shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. 1Vonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. A__mendment. This Agreement shall only be amended.by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. 4 (rev. 05/18/2018) Page 2 of 3 0'vVNTER: By: ignature) Date: -11 14/7-0 7-0 �(print name) STATE OF ALASKA )ss. cv5 J'"""" JUDICIAL DISTRICT The foregoing instrument was acknowledged before me this'L#t day of Ak� 20 p, by IVN"A- 06--1) OF ALASKA NOTARY PUBLIC FOR ALASKA , PUBLIC IV NOTARY My Commission expires: Nine Wideman My COMCAUon Ends September 23, 2024 MUNICIPALITY: By: (�Mxl (signature) Re -6e c C 6g C -9-f- cc) L( (print name) Date: I /) n 13 I 1-,� 0 Title: Page 3 of 3 ~ATE I~SPECT~_ ~ TIMI"' Rr~IJEST FOR APPROVAL OF: INDIVIDUAl~ SB'IER ,ql'~D !'lATER FACILITIES ~PE FACILI~ TO ~E IF]SPE~I [tUF~ER OF B~ROOf, IS:__ !'/EI.J. ~ATA: '// C, szz~_~_ ~ .... ~.~_~.,/./,~ ...... D, CONSTRUCTION .z/_Z~.~r-~- ..... E, BACTERIAL ANALYSIS _~-"~.~--~?~-C~,?,,.~:.~5,¢~- S~,tA~_ DZS~SAL SYSCO, SEPTIC TAt;K (IF l'JOi'qEl"¥q~E.. S1'1091 DIAGR/VVj ON ]]ACK) t4, I~-ISTAU. J:.~ ..... APPROVAL R.. U,,. :,T ' . o,: ..:u~ : ~'ATER FACILITIE2 ,~-~,.~ /F; ¥_../_¢_..C~_ C,DIS~SAL FIEU)' 1, ;~U/,~ER OF 7, ~{EOUIR~ :EASUR~B~ITS WELL TO ~, WELL TO~*' D, NELL TO PROPERTY t.I:IE.__J~ F, FOU~'~ATIOR TO SE~IC T~4K FOUNDATIO .1 TO SEEPA6E PIT. 8EEPA6E PIT TO PROPE~ LINE_ t ,.../.. ,. ..... ~'~ IA ~r~ ~ ) . .r f! 'A F, ' /W/,O\.£ t, LL, lob O,.E .YE.,., RI.:, .,!,TE 8I .E~, I~rll~TI.t,R/~,,I~-IOI'tA( E AREA BOROUGtt DEPARTMEi'.IT OF' BPFIRONFEITFAL eUALII'Y J m;71 1. Sewer line 2. Septic tank ~ 6, Othe~ sources off possib&e co~tamJnation~ J.,e,~ cr,eeks~ L~kes~ houses~ ba~n~ d~aina~e 6itch~ etc,~~ Age of system c., ..... ~ame o~ septic tank manuYactu~e~,, J)' 3 '~ ~ , Z. Z~ "hom~ made" show ..... . ' . Disposal field op seepaKe p~t size and type, e. PercoJ~tlo~ Te~t Yesults f. Percolation Test performed by_. ~ ~ .:~ ...., ~ Use the reverse .side of this form to shoW diagram, Diaf-ra~ should ~.nclude .~ .~he .following information: ~operty lines; .well location, house location, ~ptic tank location, disposal area location, location of percolation test~ a~.~ dtreetion of ~round slope, 9. The ~forma~ion on this form is true and correct to the best of my knowledge, Si~:nature o Applicant ' Date Szgned TO BE FILLED. ou'r BY HEALTH DEPAET{.JENT PERSONNEL ./ ~'he above descmtbed sanlta~,y faeil~ies are hereby approved, s~ubject to~ .......... ~f6~:.%gwin~ cgn~i~ons ~ The above described sanitary facilities are disspproved for the follo%~ing reasons: ..~' CPJ:cw ?