HomeMy WebLinkAboutSUN VALLEY TR C-1B MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231073 Work Type: Septic Upgrade Tax Code Number: 07813108000 Site Legal Address: SUN VALLEY TR C-113 G:0858 Site Mailing Address: 3450 HILAND RD, Eagle River Owner: MCCOMAS RICHARD E Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date Expiration Date: nt p , r Dehan-tment Lot Size in Sq Ft: Total Bedrooms: 5/10/2023 5/9/2024 244583 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing may: L 5,5uej fz, 5 Date: Issued By: Date: 3 UU�UHICC p L 7 Y ®F % H C H 0 R, i- Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERANELL PERMIT APPLICATION Parcel I.D. 078-131-08 Property owner(s) Richard McComas Day phone Mailing address 3450 Hiland Road Eagle River, AK 99577 Site address same Legal description (Sub'd., Block & Lot) Sun Valley Tr C-1 B Legal description (Township, Range & Section) Lot Size 244,583 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank 19Upgrade N Duplex (D) ElHolding Tank ElRenewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Is TR -P (Signature of property owner or authorized agent) a Permit/Rush Fees: -#5C Waiver Fees: Date of Payment: Date of Payment: 1 6 Receipt Number: 05566G Receipt Number: Permit No. (�S/%,23/10 Waiver No. 0 Permit App_::- : :'-:c Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 17 April 2023 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road P. O. Box 196650 Anchorage, Alaska 99519 Subject: Sun Valley Tr C-1B 3450 Hiland Rd Eagle River, AK Septic System Upgrade Permit Request This is a design narrative for a permit to install a septic system upgrade on the subject property. The proposed upgrade will serve an existing three-bedroom (3) house. This lot and surrounding lots are served by private wells. Currently there are no wells within 100 feet of the proposed upgrade. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC on 11/4/2022. Groundwater was observed during the excavation of the test hole at a depth of 8.0’ BGS, bedrock was not encountered. Groundwater was observed at a depth of 8.0’ BGS in the test hole monitor tube after 7-day groundwater monitoring. Based on the results of the percolation test and overall soils appearance an application rate of 6.0 gpd/SF was used for the design of an advanced wastewater treatment system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: The South Fork of Eagle River run south to north through the subject property as shown on the attached site plan. The proposed installation will maintain a minimum of 50 feet from the mean high-water level of the river. A registered land surveyor shall stake this setback prior to the system being installed. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231073, Deb Wockenfuss, 05/10/23 Page 2 of 2 Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 4. Topography: Please see attached site plan for area topography. There are slopes exceeding 46% less than 50 feet down gradient of the proposed drain field. The proposed drain field design conforms to the steep slope provisions of AMC 15.65.210.B.4.a. Exception. The soils in this area are Hydrologic Soils Group A which contains organics underlain by a well graded to poorly graded gravel below (GW/GP), as shown on the soils log. Due to the nature of and drainage capacity of the soils found in the area (HSG A) the designed infiltration line of 46% for septic system installation on steep slopes should be used instead of the assumed/worst case soil classification infiltration line of 25%. The slopes and soil types enable installation of the proposed system without effluent daylighting down gradient at any distance of concern. Please see sheet 2 of the attached design package for the slope detail. 5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On-Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231073, Deb Wockenfuss, 05/10/23 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) A SCALE: 1:16 (8.5"x11" PRINT) DRAIN FIELD SLOPE SECTION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231073, Deb Wockenfuss, 05/10/23 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) COMMENTS: Test hole excavated by DEANS CONSTRUCTION. PERFORMED BY: PANNONE ENGINEERING. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·<1 (min/inch) ·6" ·2 FT AND 3 FT SOILS LOG INSTALL NEW 1500-gallon (ADVANTEX) STEP TANK, AND SOIL ABSORPTION SYSTEM. 8 FEET 8 FEET Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231073, Deb Wockenfuss, 05/10/23 Wockenfuss, Deborah M. From: Whitfield, David R. Sent: Friday, April 28, 2023 1:50 PM To: Wockenfuss, Deborah M. Subject: Plat 84-369 g-• Because of advancements in septic systems which has lead to updated code requirements since the plat was recorded, I see no need to remove plat note #2. Please let me know if you have questions. v A*g pzA Planning Department MUNICIPALITY OF ANCHOPAGE Dare Whitfield Manager & Platting Officer - Planning Department C urr�n Planning Division Email: david.whitfield@anchorageak.gov Phone: (907) 343-8329 4700 Elmore Road, Anchorage, AK 99507 www.muni.org/planning MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of(Rt �, of 20 , by and between herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Advantex located at (legal description) Sun Vallev Tr C-1 B 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) OM— Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the tern of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 Mid Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. h hi Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. I fT Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: (signature) 1 name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) The forego 20_013 by _ Date: iM\�( Ca� 2,0 v -j strument was acknowledged before me thisday ofc�:( NOTARY My Comn, MUNICIPALITY: JC FOR ALASKA expires: 3J�;'I a(,5� By: (signature) (print name) (rev. 05/18/2018) Johns " o,> ' OTA, = o nj,iOC/B LAG . O F P\sP' r s0- - - tc, Date: -� �D 23 Title: Page 3 of 3 4 �I 7•s.7. it' „000eo®y '� Q► � s ,,.. ®P •N PO q. " $ }3obert C. l4, ilson =. No. 88'J-Sh�4 MEM AS -BUILT I hereby certify that I have surveyed the following described property: M 7: C L F .3 SvAJ VA-L1.A_r Y.�'LsB'b�y Anchorage Recording Precinct, Alaska, and that the improve- ments situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Eagle River, Alaska r this ZG' 41C day of -P-40-5-- 19 _ ROBERT C. JOHNSONi� , SCALE: Registered Land Surveyor'Nr* LS Box 77-0456, Eagle River, Alaska 99577 Phone (907) 699-2543 1 r �� � i ti � 11 7•s.7. it' „000eo®y '� Q► � s ,,.. ®P •N PO q. " $ }3obert C. l4, ilson =. No. 88'J-Sh�4 MEM AS -BUILT I hereby certify that I have surveyed the following described property: M 7: C L F .3 SvAJ VA-L1.A_r Y.�'LsB'b�y Anchorage Recording Precinct, Alaska, and that the improve- ments situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Eagle River, Alaska r this ZG' 41C day of -P-40-5-- 19 _ ROBERT C. JOHNSONi� , SCALE: Registered Land Surveyor'Nr* LS Box 77-0456, Eagle River, Alaska 99577 Phone (907) 699-2543 jasn ` � nom` 'ter, Al I % J 7•s.7. it' „000eo®y '� Q► � s ,,.. ®P •N PO q. " $ }3obert C. l4, ilson =. No. 88'J-Sh�4 MEM AS -BUILT I hereby certify that I have surveyed the following described property: M 7: C L F .3 SvAJ VA-L1.A_r Y.�'LsB'b�y Anchorage Recording Precinct, Alaska, and that the improve- ments situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Eagle River, Alaska r this ZG' 41C day of -P-40-5-- 19 _ ROBERT C. JOHNSONi� , SCALE: Registered Land Surveyor'Nr* LS Box 77-0456, Eagle River, Alaska 99577 Phone (907) 699-2543 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264.4720 ON-SITE SEWAGE DISPOSAl. SYSTEM AND/OR WELL INSPECTION REPORT NAME ) PHONE MAILING ADDRESS LEGAL D ESCRIPTIO_I~._¢~'~ WellF LOCATION DISTANCE TO: Manufacturer DISTANCE TO: inside length Dwelling Well Foundation DISTANCE TO: No, of lines Top of tile to finish grade Total length of lines Material beneath tile Length I Width 7~ / Dep~ J Type ~ Crib diameter Crib depth DISTANCE TO: DISTANCE TO: uiJding OTHER PIPE MATERIALS Material Nearest lot line Trench width SOIL TEST RATING / / REMARKS ~I~UPGRADE NO. OF B~OOMS PERMIT NO. No. of compartments__z~ Liquid d~d~d~h ..... PERMIT NO, Liquid capacity in gallons PERMIT NO, Distance between lines Total effective absorption area PERMIT NO. ¢-, Total effectiTe~or tionae Nearest lot line Driller Distance to lot line I PERMIT NO. Sewer line Septic tank I Absorption area(s) DATE MUNICIPALITY OF ANCHORAGE Department ~f Health and Environmenta 825 Street, Anchorage, AK. 264-4720 ~'~'_ F) * * * HANDWRITTEN PERMIT * * Permit ~~6~FN. WELL AND/OR ON-SITE SEWER PFRMIT Legal Description: · ype of 8oil ~sorption Syst~ Is: Trench: Drainfield: Maximum N~ber of Bedrooms: Protection ~9501 Mailing Address: Phone Number: Lot ~/ Seepage Bed: Holding Tank: Soil Rating(sq.ft/br) I O ,O The Required Size of the Soil ~bsorption System Is: DEPTH LENGTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE TM /~O GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this departmeni will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25'feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams available to insure proper installation. * * * PERMIT EXPIRES DECEMBER ~1~ 1 9 ~ 3 * * * I certify that: (1) I ~n familiar with the requirements for on-site sewers set forth by the Municipality of Anchorage. I will install the system in accordance with codes. I understand that the on-site sewer system may require (2) (3) Signe~: are and wells as enlargement if to include more that 3 bedrooms. =s sued by:jL % L .s. SWP/024(1/81) SOILS LOG MUNICIPAt. ITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG '- PERCOLATION TEST [] PERCOLATION TEST SLOPE 2, 3 4 6 toO [)ATE PERFORMED: SITE PLAN 10 WAS GROUND WATER 11 ENCOUNTERED? 12 IF YES, AT WHAT DEPTH? 13 14 15- 16- 17 18 19- Gross Net Depth to Net Reading Date Time Time Water Drop 20'- COMMENTS PERCOLATION RATE f~//7 (minutes/inch) TEST RUN BETWEEN FT AND FT CERTI FI E~~(/~/