HomeMy WebLinkAboutSUSITNA SUNSET LT 4
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Pump Installation Log
Well Drilling Permit Number: _______________ Date of Issue: ____-____-____
Parcel Identification Number: ____-____-____
Legal Description Block Lot Property Owner Name & Address:
Pump Installation Date: _____-_____-_____
Pump Intake Depth Below Top of Well Casing: __________ feet
Pump Manufacturer’s Name: ___________________________ Pump
Model: _____________________________________
Pump Size: ____________hp
Pitless Adapter Burial Depth: _________ feet
Pitless Adapter Manufacturer’s Name: _________________________
Pitless Adapter Installer: ____________________________
Well Disinfected Upon Completion? XX Yes No
Method of Disinfection: _____________________________
Comments:
Pump Installer Name: __________________________________
Company: ___________________________________________
Mailing Address: ______________________________________
City: ___________________ State: __________Zip: _________
Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation.
t~j MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SiTE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
· [] UPGRADE
LEG L DESCRIPTI
LOCATfON NO~EDROOMS
DISTANCE TO: Iwell /~ I Ab'°mti°~? ' '
"~ Man, facturer
Liq, capT~llons IF HOME.DE; Inside length Widtb Liquid depth
~ ~ DISTANCE TO: Well Dwelling PERMIT NO.
O Z < Manufacturer
Z -- N Material Liquid capacity in gallons
; ~ ~ DISTANCE TO; We]]~ C ~ Foundat,o,~ Neare>~t~ine .PERMIT ?~
-- No. of lines~ Length of~lin Total 1o~t~of lines Trenc%~¢ Distance ~)w¢ lines
inches Total effe~orption area
~ Top of tile tyinish grade~ Material beneath tile '~ inches
Length ¢ Width Depth PERMIT
~ ~ Type of crib Crib diameter Crib deptb Total effective absorption area
~ Well Building foundation ~ Nearest lot line
~ DISTANCE TO:
~ Class Depth Driller Distance to lot line PERMIT NO.
~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s)
OTHER
PiPE MATERIAL~ ~ . , ¢~¢
SOiL (
,¢
INSTAEL[R
REMARKS /
?,
~ J,
,UIL. RRTIN_:
THE SOIL ¢:iEE'£RP"*I'£N E'.¢STEM
]'HE LENGTH DIMENSION I:E; THE: LENGTH ,::Ii',! FEE'T) OF THE TRENCH OR DRf~!NFIEL[:,.
%HE DEPTH OF' F! TRENCFI OR F'IT IE; ]"HE DIL:.,TFtNCE BETHEEN THE E;URFRCE OF' THE
GROLIN[:, FIND THE E,'OTTOH OF' THE' E::.~CFIVFFI"_TOI,,! (iN FEE-F).
THERE 15 NO E;E]' 14IDTH FOR TRENCHE:L-';.
THE GRFI',,,'EL DEPTH IE; THE H. INII,,'!LIM DEF'TH OF GRFP/EL BE'I'HEEI,.,~ THE OLITFRLL. F'IF'E
RND THE E~OTTOM OF THE E',=:CR',/RT.tON <IN FEET).
F'ERhtZ 'T' RF'F'L i CFli,,IT HH_, THF-' RE'L: PC NE.. I E I_. i 'f"./ TO I NF-" E RH TH Z E;
IN:'STALLFITICI,.,I Ii' ..... L-.I .t ..... '"IF Ri,'~.'.'r' !-'.fELL!5 R[:,,;FRCEI,.4T
NUHE:ER - F' RFZ% :[/,EHF: E'5 THFYF 'THE !,.IELL. H
[:,EF'FIRTI,,.E~-T E:,L!RING THE
RF.:OPERT'-/ Fli,.&D THE
MINIHUH DIE;TRHCE BETHEEN R HEL. L F~N[), RN'T' OI,.,?_.'.;;ZTE SEWRGE DISPO~;RL ~SYSTEH iS
19~ FEET FOR R PRIVRTE HELL OR 150 TO 20P.~ FEET FROH R PUBLIC HELL DEF'ENDZNG
LtPON THE T?PE OF PUBLIC HELL
MINZMLIh~ DIE;TRNCE FROM FI F'RZVRTE HELL TO F4 PRZ',/RTE SEHER LINE IS 25 FEET RND
TO R COHMUNIT'¢ ~SEIqER LINE I9 75 FEET.
OTHER REQUIREHEI',iT~; i'dR'.? F!PF'L.'¢. LSF'ECIFICF~TIONS RN[:, CONSTRUCTION [:,IFIGRRMS RRE
R',/FiILiRBLE TO INSURE PROPER !N%T[~L. LRTION.
I CER'T'IF'¢ THF!T
i: I Ri',i FFti,,'K[L. IRR HtTH THE REQU!REI','!ENTf5 FOR ON-STTE :'SEHERS FIND HEL.L2~ RE; E;ET
FORTH Bb.' THE I,]UI,.,I:[CZF'FILZT'¢ OF F!NCHORRGE.
2: I HILL iNSTRLL. THE S'T'~'J'f'E!"! Ii'.,! RC:CORDRNCE !.4~TH TFIE CODE~.
~:: Z UNDER~TRND THRT ]"HE ON-SITE L::;EHER S'¢.?rEi,,~ t"IFYT' REQUIRE ENL. iaRGEMENT IF THE
825 .... c ....
L ,~FREEq
AIXICHORAGE, ALASKA 99501
(90'/) 264-4111
GI~ORGE M, SULLIVAN,
A,IA Y 0 R
DE?A£~TMENTOF HEALTH AND ENVIRONMEN]ALPROTECTION
December 31, 1980
Steve Agee
Box 2468
Anchorage,
Alaska 99510
Permit # 800459
Subject: Lot 4 Susitna Sunset Subdivision
A permit issued by this department for well and/or sewer
system has expired as of this date.
Permits are issued on a calendar year basis, as stated on
the permit~ by authority of Municipal Ordinance.
If you have drilled the well, a well log should be sent
to this department to document the installation date.
If an engineer inspected the installation of the on-site
sewer system, please have them send us the as-builts for
our files.
If there are an~ further questions please call this
office at 264-4720.
S inc er ely, --/
Les N. ~UC · , S./~/
Senior Environmental ,~p~cialist
LNB/ljw
enc: Copy of Permit
SWP/057
RPPLICRNT STEVE RGEE BO~ 24~8 RNCH. RK.
LOCRTION COTTONTRIL
LEGRL LOT 4 SUSITN8 SUNSET SUB. LOT SIZE
~44-267±
~6430 SQURRE FEET
TYPE OF SOIL RBSORPTION SVSTEM IS: TRENCH
MR~IMUM NUMBER OF BEDROOMS
SOIL RRTING (SQ FTZBR)= 258
THE REQUIRED SIZE OF THE SOIL 8BSORPTION SYSTEM IS:
[:,EF"TH= 2~ LE~'-~GTH= S~24 6 P.. R'-.¢ E L EaEPTH= 5
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTN OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE
GROUND RND THE BOTTOM OF THE E~CRVBTION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRBVEL BETWEEN THE OUTFRLL PIPE
RND TNE BOTTOM OF TNE EXCRVRTION (IN FEET).
~:E~]-.~Li Z F;ED SEPT I ;]: TI~--~'-~--'. S,, T ZE= 1E~OE~ ,3RLLO~'-~S
PERMIT BPPLICRNT HAS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE
INSTRLLRTION INSPECTIONS OF RN9 WELLS BDJRCENT TO THIS PROPERTY' BND THE
NUMBER OF RESIDENCES THBT THE WELL WILL SERVE.
BRCKFILLING OF FINY SYSTEM WITHOUT FINRL INSPECTION FIND RPPROVRL 8'~' TNIS
DEPRRTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTRNCE BETWEEN R WELL RND RN'T' ON-SITE SEWRGE DISPOSRL S'~'STEM IS
±00 FEET FOR B PRIVRTE WELL OR ~[50 TO 200 FEET FROM R PUBLIC WELL DEPENDING
UPON THE T'~PE OF PUBLIC WELL
MINIMUM DISTRNCE FROM R PRIVRTE WELL TO IR PRIVRTE SEWER LINE IS 25 FEET RND
TO R COMMUNITY SEWER LINE IS 75 FEET.
WELL LOGS RRE REQUIRED RND MUST BE RETURNED TO THE DEPBRTMENT WITHIN Z..O DRYS
OF THE WELL COMPLETION.
OTHER REQUIREMENTS MFI'~.' FIPPLY. SPECIFICRTIONS RND CONSTRUCTION DIRGRRMS FIRE
R',?RILRBLE TO INSURE PROPER INSTRLLRTION.
F:'EF:~'~ ir T E::-~P ][ t~ES [:,ECE~"~BER _~--~-1 ..
I CERTIFY THRT
±: IRM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET
FORTH B~r' THE MUNICIPRLITY OF RNCHORRGE.
2: I WILL INSTRLL THE S'~"STEM IN 8CCORDRNCE WITH THE CODES.
]:: I UNDERSTRND THRT THE ON-SITE SEWER SYSTEM MRY RE.qUIRE ENLRRGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THFtN 7~: BEDROOMS.
CON 1 I ]C'-i-tON
TEST LAB
PERFORMED FORL AGEE
LEGAL DESCRIPTION:
THIS FORM REPORTS:
Lot 4 Block
[] Visual Soils Examination
18OL..~W. 48TH AVE. STE 'C'
ANCHORAGE, ALASKA 99503
248-i333
DATE PERFORMED: q/q/R0 ......
Subdivision_ Su,qi ~-na ,qun~t
~ Percolation Test
DEPTH
FEET
I--
2,5 t
SOIL NOTES
DESCRIPTION
Topsoil
GRV-SA
DRY
SA-GRV
DRY
SI-SA-GRV
DRY
GM
BOTTOM OF HOLE
WAS GROUND WATER ENCOUNTERED
IF YES, WHAT DEPTH
LEGEND
® -- Parc zone
~,S - Sample loken
I~ -- Frozen zone
~' -- Water table
READING ~ DATE
_ 9/03/80 I
I 9/05/80 I
I ~
NO
--
GROSS TIME t NET TIME
SATURATIO~ PERIOD
5:30 / 0 Hrs.
6:30
6:45
7:00
PERCOLATION RATE: 30 Min./Inch DRAINAGE REQUIREMENTS: 250 Sq. Ft~B_~
PROPOSED INSTALLATION: [] SEEPAGE PIT ~D DRAIN FIELD [] OTHER
COMMENTS:
TEST PERFORMED BY: L.S~ DATA CERTIFIED BY: Kinney_ R. Baxter, P.E.
DATE:~9/_0~5/80 _
3 1/2_"
6 1/4"
6 _3~/_4
NET DRAINAGE
2 _1~4"
1./2_IL
l_l1 Hr.
1/4 tIr.
2 Hrs.
DEPT'H TO H20
\
WATER WELL RECORD
~'/ STATE Of ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of GeOID§iCOI 8~ Geophysicol Surveys
Drilling Permit No.
A.D.L. No.
911a. Borou'ou~'"- Sub,division Lot Block~-~l I/4qtrs. Section No. TownshiPN[~ RanGe E~ Meridian
OlS~ DIREC~.,~uM ~uA~RSECTION$ ~. OWNER Of WELL:
Feet Below 4. W. f~ PT"' [final} 5.~JTE OF C.MPLETI~N.
Material Type Top Bottom
' ' / 7.S 6. ~ c.~,,
/
5?k O~V~C 'il0 f> diam. in. to ft. Depth S li~ ....... ft.
I0. STATIC WATER LEVEL:
MUNI~IPALI~ ~¢
ENVi~ONM~N'iAL PROTE~ION
~ ~ ~ ~!.~_ ~~ ms. PUMP: (if ovailoble) HP
~RAgistered/Business Na~ _ -- ~ / C°ntr~ct Li~fl)~J~ff~/
(907) 243-7893
F;EN JOP~NSON
WATER WELL DRILLING
PUMP SALES & SERVICE
Steve AGEE
Lot 4 Susitna Sunset
AnE:ho r~g'.e ~
NIUNICIPALITY OF ANCHORAGE
DEPT. OF HZALTFf &
ENVIRONMENTAL ~ ZO'I'ECTION
JAH 1 4 I981
RECEIVED
3~63 LINDEN DRIVE
ANCHORAGE, ALASKA 99502
October 8~ 1.980
0 ftc
8
1~ fro
17
21 ft~
27 ft~
60 ft~
110 ft.
to 8 ft. Brown silt and ~ravel
to 16 ft. Gravel with some light Brown silt
to 17 ftc
to 21 f~. silt
to 27 2'I~. (drcve casing to
Bculder
Gravel with bro~
Decomposed bedrock
to 60 f'~, Firm bedrock ( light grey )
to 110 ft. Same but weeps wate~~
refusal )
to 175 ftc Firm rock with occasional fractures ( dry )
Total depth 175 ft.
Total casing 29 ft.
Static water level 32 f't.
14~ ft coloumn of water in well
Yeild I GP~
Drawdown 100%
fai~ recovery
( 215 gals, )
1940 POST ROAD
ANCHORAGE, ALASKA
99501
July 3, 1974
W.O. #16756
279-2581
Alaska Land Development
8730 Lake Otis Parkway
Anchorage, Alaska 99507
ATTENTION: Mr. Bill Tucker
SUBJECT: Seepage Pit Test Hole~
LOCATION: Susitna Sunset Subdivision
Gentlemen:
Transmitted herewith are the results of the subsurface investigation performed
on the above property on June 18, 1974. Exploration consisted of 2 - 15' test
hole drilled by Denali Drilling, Inc., employing Nodwell mounted, Mobile B-SO
drill, fitted with an 8", solid core, continuous flight auger. Grab samples
were taken at 5' intervals, by pulling the auger out of the test hole and re-
moving the sample from the flights of the auger from near the bit. The soils
were visually classified in the field in accordance with sheets 1 through 3,
following the text. This field classification was verified by visual review
of samples based on the same criteria, in the laboratory. The drilling was
supervised and the test hole was logged by L.B. Johnson, senior technician of
our staff. The test holes were logged as follows:
Test Hole 1
Depth in Feet
From To
0.0' 1.0'
Soil Description
Brown organic overburden
1.0' 4.0'
F-4, brown gravelly sandy silt w/occasional
cobbles, damp to wet, hard, Pi+, SM/ML
4.0' 1S.0' :
F-2, brown silty~sand, damp, high
density, SM >
.Bottom of Test Hole:
15.0'
Frost Line:
None Observed
Free Water Level:
None Observed
--- c ° n t i n u e d-~~3
1974
MEMBER
Alaska Land Development
Page 2
July 3, 1974
W.O. #16756
Sample ~epth
1 4.0'-5.0'
2 9.0'-I0.0'
3 IS.0'
Remarks:
Type of Sample
GRAB
GRAB
GRAB
1. Test hole located 150' from Huffman along power line
2. Elevation: existing ground
3. Date of exploration: June 18, 1974
Test Hole 2
Depth in Feet
From T~
0.0' 0.3'
0.3' 1.S'
1.5' 13.0'
13.0' 15.0'
Bottom of Test Hole:
Frost Line:
Free Water Level:
Soil Description
Brown organic overburden
F-2, brown silty sand, damp, high density, SM
F-2, brown silty gravelly sand, damp, high density, SM
F-2/NFS, brown silty gravelly sand, damp, high density,
sM/sp
15.0'
O.S' - 1.0'
None Observed
Sample Depth
1 5.0'
2 10.0'
3 13.0'
4 15.0'
Type of Sample
GRAB
GRAB
GRAB
GRAB
---continued---
Alaska Land Development
Page 3
July 3, 1974
W.O. #16756
Remarks: 1. Test hole located 1S0' East of Test Hole 1
2. Elevation: existing ground
3. Date of exploration: June 18, 1974
The seepage area required per bedroom by soil type (per the Greater Anchorage
Area Borough) is as follows:
Soil Type
(Unified Classification) Seepage Area Required
ML 27S ft2/bedroom
SM 250 ft2/bedroom
SP 1S0 ft2/bedroom
SW 125 ft2/bedroom
GM 225 ft2/bedroom
GW 85 ft2/bedroom
Soils requiring greater than 2S0 ft2/bedroom are not allowed in seepage pit
area calculations (per the Greater Anchorage Area Borough).
The seepage area required at depth ca'n be expressed as follows:
TEST HOLE 1
Unified Soils
Depth Classification
0.0'-1.0' PT
1.0'-4.0' SM/~L
4.0'-15.0' SM
TEST HOLE 2
': :' Unified Soils
pept~ Classification
0.0'-0.3' PT
0.3'-1.5' SM
Seepage Area
Required
Not Allowable
Not Recommended
250 ft2/bedroom
Seepage Area
Required
Not Allowable
250 ft2/bedroom
---continued---
Alaska Land Development
Page 4
July 3, 1974
W.O. #i6YS6
TEST HOLE 2 (continued)
Unified Soils
Depth Classification
1.5'-13.0' SM
13.0'-1S.0' SM/SP
Seepage Area
Required
250 ft2/bedroom
200 ft2/bedroom
Enclosed are some excerpts from State and Borough ordinances which may
be of value to you. For further restrictions, particularly with ref-
erence to location of the seepage pit, we call your attention to the
Greater Anchorage Area Borough Ordinance 28-68.
Please call if we can be of further service.
Very truly yours,
ALASKA TESTLAB
~John ~1. Lambe
Harry R} Lee~ P.E.
JML/vms
Enclosures
Page 15
Ordinance No.
(a) No seepage pit excavation shall extend into
th~ water table. Where g~ound water is encountered,
the bottom of the pit shall be backfilled with clean
above the water table.
(~) The top of all seepage pits shall be nq~ less
than 18 inches below the fi'nished grade.
(c.) ~e required absorption area of seepage pits
shall be computed.on the basis of percolation tests
made in each vertical stratum penetrated. The
weighted average of the results shall be computed
obtain a design figure. Soil strata in ~hich the
to
percolation rates
inch shall not be
absorption area.
(d) Seepage pits
are in excess'of 30 minu~es per
included in computing the
Shall not be installed in areas
where the percolation ~ate is greater than 30
minutes per inch, i.e., in areas where more than
30 minutes is required .for the water in the test
hole, after proper preparation,.to fall one inch
.(e~) Table No. 4 shall be used to compute the
required seepage area for seepage pits.
(f) The effective seepage area of a seepage pit
Shall be the vertical wall area, based on dug
diameter, of the pervious strata below the inlet.
(g) The lqcation of seepage pits shall be such
as ~o provide not less than the stated distances
from the followi, ng: '
Page 16 ~
Ordinance No. 28-68
TABLE NO. 6
1. Any Source of Domestic Water Supply
100 feet
~ 3. River~ Lake, or Stream lO0
4. Watermai~ or Service Line l0
5. Other Seepage Pits (3 times the diameter of
seepage pits.)
6. Septic Tanks
(h) The seepage pit shall
building tile, perforated
or other material
feet
feet
the
be lined with brick,
Drecast concrete rings,
approved by the health authority.
The.space between the outside of the li.ning and
:he soil shall be backfilled with clean coarse
gravel or similar material. The lining shall be
rrounded on all sides by at least 2 feel of
clean coarse gravel or similar material.
(i) The sewer line draining the septic tank
effluent to the seepage pit shall be of cast iron
from the seepage pit lining to a point not less
than 5 feet beyond tl~e nearest undisturbed soil
unless suitable bedding material properly
compacted is used to support the line.
(j) The top of the seepage pit shall be 'covered
with a reinforced concrete, top or other material
approved by t~e health authority.
Page 17
Ordinance No.
2~
(k) A!.I seepage pits shall be provi.ded with
a cast iron siphon Pipe of 4" diameter or larger.
All siphon pipes shall be fitted with an air-
Cesspools shall not be used for disposal of ~,ouse-
hold wastes unless specifically authorized by .the
health authority.
(al' Cesspools
where ground water supplies
domestic purposes.
(b) The construction of cesspools sh~)l
follow the same standards as those given for
seepage pits.
(C) Exemptions.
1. All septic tanks, drainfields, and seepage pits
in use on September, 1968, are exempt from subsections
(B) (5), (B) (6), {D) (7), (B) (8) (b), (B) (2) (c),
(B) (8) (d), (B) (el, and (B) (8) (fl of this section°
Sec. 9-72 IJO__~N__bI_ATER-CARRIED SEF!AGE ~TSPOSAL SYSTEIq. So
(Al The construction and maintenance of earth pit privies
shall comply with the following requirements.
1. Earth pit privies
from any spring, well
water supply; lO0 feet
shall not be used in areas
are used for
feet
shall be located at least lO0
or other source of domestic
from any stream, river, or
lake; and lO feet from any watermain, water service
line or property line.
2; Earth pit privies shal?
in the Alaska Department of
be constructed as recommended
Health D~cument HSE 762,
~.~, MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
GENERAL INFORMATION
(a)
(b)
(c)
Legal Description (include Iot,J~ock, subdivision, sectiop,~township/~ran,~.
Location (address or directionsJ / ~//~ ~_ '7//
Applicant N~me~~ ~ ~-~ - Te,ephone: Home
Applicant Address ~
Applicant is (check one): Lending Institution ~; Owner/builder~Buyer ~
; Other [] (explain);
(d) Lending Institution
Address
(e) Real Estate Company and Agent
Address
Telephone
(f) Mail the HAA to the follo~wir~g addrsss: /.
3. .WATER SUPPLY'
TYPE OF RES.~ENCE.
Single-Family [~_i Multi-Family [] Other
Number of Bedrooms ~' ~
Individual Wel Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL · ·
Onsite [] Public [] Community [] Holding Ta~e'~~''~ ·
Note: If community weJJ system, must have~n confirmation from the State Department of Environmental Conservation
attesting to the legality and~
Page 1 of 2 ..~ . 72-025 (11;84)
NGINEERING FIRM PROVIDIN~G~NSPECTIONS, TESTS, FILE SEARCH, DAit--~/,~,ND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance.with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm ~ ~-~.-~,~ o--~. /'~/~ Telephone
Address
r.j
Date
Engineer's Seal
DHEP APPROVAL
Approved for 'f~'~ ~'~","~ bedrooms by
Approved ~ Disa p~..ved Condi~nal
Terms of Conditional Approval
Date "2.. ~l t' - ~,
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF iNSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date
GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Applicant Name .~'l~x~,.~ /:~,,~' Telephone: Home ,~ ¥,5°°O'¢'&~ Business
Applicant Address
(c) Applicant is (check one): Lending Institution []; Owner/builder' []; Buyer []; Other [] (explain);
(d) Lending institution Telephone
Address
(e) Real Estate Company and Agent
Address
Telephone
(f) Mail the HAA to the following address:
TYPE OF RESIDENCE
Single-Family FA Multi-Family []
Number of Bedrooms -~
Other
WATER SUPPLY
Individual Well [] Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite [] Public [] Community [] Holding Tank []
Note: If community weli system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (1~/84)
ENGINEERING FIRM PROVIDING~'dlNSPEcTIONS, TESTS, FILE SEARCH, DAT~A~AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the o n-site water supply and/or wastewater disposal system is safe, fu nctional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances! and regulations in effect on
the date of this inspection. ~'
Name of Firm Flczf"/-~fl ' ~C~J ~ Telephone ~E~- l~6--
Date I/~ ~
DHEP APPROVAL
Approved for '~
Approved
. bedrooms by
Disa"~:)ved . Con(~nal
Terms of Conditional Approval
Engineer's Seal
~fft, g.x .'.. .......
~ * THEODORE F MOORE
Date
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP} issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professionel
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (1u84)
WELL DATA
,~ ,,,~ ~IMUNICIPALITY OF ANCHORAGE (MOA)
CHECKLIST- FEBRUARY 1984
264-4720
~,AN~ Legal Description: ~o~
Date Completed
Depth of Grouting
Well Classification
Y
if A. B, C, D.E.c. Approved (Y/N)
Yield
Pump Set At ~ l
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
Well Log Present (Y/N) _
Total Depth I '"~.~' Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit
Separation Distances from Well:
To Septic/Holding Tank on Lot ~ ii"
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
Cleanout/Manhole
; On Adjoining Lots
I O'~" ; On Adjoining Lots
To Nearest Public Sewer
TO Nearest Sewer Service Line on
Water Sample Collected by
Water Sample Test Results
Comments ~4,,'~ ~-~ I ~c]~/~
SEPTIC/HOLDING TANK DATA
Daie Installed ? / 2~ ,/aa size
Standpipes (Y/N) ~ Air-tight Caps (Y/N)
Depression over Tank (Y/N)
Pumping/Maintenance Contract on File (Y/N)
Holding Tank, High-Water Alarm (Y/N) -
Separation Distances from Septic/Holding Tank:
To Water-Supply Well ~ ~ ~
To Property Line
To Water Main/Service Line
Course ,~' ~'OO '
No/of Compartments
¥ Foundation Cleanout (Y/N)
Date Last Pumped
; for
.T~mporary Holding Tank Permit (Y/N)
To Building Foundation
To Disposal Field
To Stream, Pond, Lake, or Major Drainage
Page 1 of 2 /
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed 7/~ ~-~ /~ ~,
Width of Field $6"'
Square Feet of Absorption Area
Depression over Field (Y/N)
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well I0~°
To Building Foundation
Lot N. ,~.
To Water Main/Service Line
Length of Field
Depth of Field
Gravel Bed Thickness
Standpipes Present (Y/N)
Date of Last Adequacy Test
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
Type of System Design
To Property Linde ~, ~0 '
To Existing or Abandoned System on
; On Adjoining Lots ~' $~ '
To Cutbank (if present) pi.R,
~' tO0'
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test, Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Date
MOA No.
Signed ,o'r~
Company
Receipt No.
Date of Payment
Amount: $
Page 2 of 2
72-026 (11/84)
Engineer's Seal
Municipal ty
of
Anchorage
P.O. BOX 6650
ANCHORAGE, ALASKA 99502-0650
(907) 264-4111
TONY KNOWLE$.
MA YOR
DEPARTMENT OF HEALTH & HUMAN SERVICES
January 28, 1986
Ted Moore, P.E.
Flattop Technical Services
14530 Echo Street
Anchorage, Alaska 99516
Subject: Lot 4 Susitna Sunset Subdivision
Waiver REqust, WR86-012
Dear Mr. Moore:
Your rstuest for a waiver of the i00 foot separation required between a
septic tank and well has been approved for the subject lot. The required
distance has been waived to 95 feet.
This waiver is valid for the existing septic system serving a three bedroom
single family dwelling.
Sincerely,
Stephen S. Morris
Civil Engineer
On-site Services
SSM/ljw
C~ & EN~ON~NT~ ENG~EER~G · ENERGY CONSERVA~ON & ~YS~
T~ODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 345-1355 3anuary 20, 1986 ~CHO~GE, ~KA 99516
Steven Morris
M.O.A. Dept. of Health and Human
P.O. Box 6-650
Anchorage, AK 99502
Services
Dear Mr. Morris:
By means of this letter I wish to request a waiver of State
well-septic tank separation criteria down from 100 feet to 95
feet on Lot 4 of Suisitna Sunset S/D. While conducting an
adequacy test on the wastewater system serving this property I
found the nearest corner of the septic tank to be approximately
97 feet from the well. Several factors support the granting of
this minor waiver. Please refer to the enclosed well log and
septic system inspection report.
When inspected by a municipal inspector at the time of
construction, the separation distance was reported as 100 feet.
It is not considered likely that the ground has shifted
sufficiently in the intervening years to cause the noted
discrepency.
The ground surface at the septic tank is approximately 20
feet lower than at the well casing, which in the event of a
failure of the septic tank would tend to direct effluent away
from the well. No water table was encountered in the test hole.
The well log shows firm bedrock starting at 27 feet in
depth, with the water bearing stratum between 60 and 110 feet in
depth. This solid bedrock should effectively prevent any stray
coliform bacteria from making their way into the deep aquifer.
Please feel free to call me if you have any questions on
this request. Thank you for your assistance.
cc. Steve Agee
Sincerely,
Ted Moore, PoE.
m
0
o
> < ',n OD
<o _--" ~' GO
Z
j'~.i_ I'Yy'"'°l'/°.2 tO2Zl
9ISG6 n~sn[¥ 'eSn.~oqou~
~.ee.qS oqo~ OCS~I
saol.i.[aS [oo!uqoe.l. dollnL4'
ENCROACHMENT PERMIT j
· His. A REF E T, made this day of , ,
between ANCHO~GE, Grantor, an~ S~ve or ~rri Aq~/ ,
Grantee,
WITHNESSETHz- ~e Grantor does hereby grant an Encroachment
Permit in the following described Public Right-of-Way or Easement
Area to wit~ susf~ S~set S~ivision, ~t-4, l~ted ~ ~e ~1/4~
· ' Gr~d~ 2740
_[ 12301 Cottontail Trail )
The encroachment hereby author zi-~d is described as and limited to
the followtng'__~klg_~ of a sewer stand pipe for clean, out that
encroaches appro~nately 10.4' (~ into Cottontail .Trail Right-Of-Way
~s shown on attachment "A"
In consid~raEi~n for this permit, th~ Grantee agrees that
he will indemnify and hold harmless the Grantor against any and
all claims which may arise or be caused b~ ~he .construction,
alteration or maintenance and existence of the above described
encroachment or for any damages whatsoever arising out of the
granting of this permit.
The Grantor reserves the right to revoke this permit upon
twenty (20). days written notice to the Grantee. The Grantee,
agrees upon said notice of revocation, to immediately remove said
encroachment from the easement, street or public right-of-way.
Should the Grantee refuse or fail to comply with said written
notice, the Grantor, may without further notice to the Grantee,
remove or'cause to be removed the encroachment, and the Grantee
hereby agrees to reimburse the Grantor for all cost incidental to
the removal thereof. The Grantee hereby agrees to pay an annual
fee of $ 1~.~0 ·
IN W/TNESS wHEREo~, the parties hereto have hereunto set
their hand~ and s~als t~day and year first above written.
Gr an~e~/~ ~~ Grantor ~ ANCHORAGE
~ D--~rec~o~,'P~b-~c~Works Dept.
STAT ALAs
THIRD JUDICIAL DISTRICT)
·
19~, before me, the un~ersigned,
State of ~l~a, ~ly~workanO eo~issioned as such, ~onally
BPpeare0 ~. ~. //~ , k~own to me to be %he
Municipal En~neer of the Municipality of Anchorage, who executed
%he foregoing instrumenk
said ins%r~ent as ~he free and voluntary a~ and deed of sald
corporation for the uses and purposes therein mentioned, and %hat
he/she wam. authorizeO ko execute sai~ instrument.
WITNESS my hand and official seal the day and year
in this certificate first above written.
STATE OF ALASKA )
THIRD JUDICIAL DISTRICT )
"y Conuuission Expires:
BEFORE ME, the undersigned, a Notary Public in and for
Alaska, duly ~ommi~sio~d ~d sworn as such, this day personally
executed the above instrument and ~. acknowledged to me
that and sealed the same freely and voluntarily for the
uses and purposes therein mentioned.
ITNESS hand and notarial seal this /~ day of
NOTARY PUBLIC IN AND FOR
My co.,issio. E×pires,, Y ¥/f7
5' I.)flL, I T~/ I:-5t~'T';, t--
LoT '~' ~
5c, LE 1"=.40
Z'/,, /
E~SEMENT~ OF RECORD, OTHER THAN
THOSE SHOWN ON THE RECORDED
PI.AT ARE NOT SHOWN HEREON.
SET THIS o^TM
hereb~ ce~d~ that I: have ~ormed a M~tgagee's in-
k.don ~ ~e f~o~g d~ ~ L~ ~
m~ ai~at~ th~n ~ ~ the p~ ~ ~d ~
that no ~v~en~ on p~ ~g ~a~t ~
ROBERT T. KEAN & ASSOCIATES
FLATTOP TECHNICAL SERVICES
CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS
TItEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 345-1355 January 20, 1986 ANCHORAGE, ALASKA 99516
Steven and Terri Agee
12301 Cottontail Trail
Anchorage, AK 99516
Dear Mr. and Mrs. Agee:
Per your request, on January 16 I tested the well and septic
systems serving your residence on Lot 4 of Suisitna Sunset S/D
for adequacy to qualify for Municipal Health Authority approval.
The septic system is capable of absorbing effluent at a rate in
excess of 80 gallons per hour which is more than adequate for the
3 bedroom home it was built to serve.
At the time of the test the well produced a total yield of
of 7.57 gallons per hoar or 182 gallons per day. This yield is
only slightly greater than the 150 gallon per day design
requirement for a one bedroom residence. Thus your home can only
technically qualify for formal Health Authority Approval as a one
bedroom residence. However, the following factors support the
conclusion that the water supply is fnnctionally adequate for at
least a two bedroom residence.
The total depth of the well is 175 feet, and the static
water level at the beginning of my test was 66 feet below the top
of the casing. This means that there is a reservoir of 160
gallons of water in the well which can be drawn upou at any time.
Thus there is ample water availab]e for any short-ter~ surge
demands such as for showering or washing clothes.
The 150 gallon per bedroom per day design standard is
conservatively based on the assumption that every bedroom is
occupied by two people who each use 75 gallons per day.
Nationally, the average p.er capita usage is approximately 45
gallons per person per day. Thus the measured rate is adequate
for 4 average people. Water couserving measures or devices can
easily reduce actual consumption well below the national average.
At the time the well was drilled in October of 1980, the
driller measured a yield of 1 gallon per minute, which is more
than adequate for a three bedroom residence. Bedrock wells in
the Hillside area often show a marked decrease in yield during
the coldest winter months when the aquifers are no longer being
recharged, and the higher yield then returns during the summer
months when demand is often greater. I would expect the yield
of your well to be greater if measured in the summer.
I noted that the pump is equipped with a device to protect
it from running dry and overheating, should an unusually large
water demand cause the 160 gallon reservoir to be expended. This
is a good safety precaution to take in the case of a low yield
well.
The water sample taken on January 6 was satisfactory with no
evidence of coliform bacteria.
For the above reasons, I believe that this well should
continue to provide an adequate water supply for you and your
family. Please feel free to call me if you have any questions.
Sincerely,
Theodore F. Moore, P.E.