HomeMy WebLinkAboutSUSITNA VIEW ESTATES BLK 3 LT 15ustTt:A
M
LST
Permit Number:OSP251383
Tax Code Number:02009134000
Work Type:Septic Upgrade
Effective Date:
Design Engineer:
Site Legal Address:SUSITNA VIEW ESTATES BLK 3 LT 1 G:3336
Owner:NEITHERCOAT WILLIAM J III
Site Mailing Address:17030 ARIES CT, Anchorage
Lot Size in Sq Ft:21301
Total Bedrooms:3
This permit is for the construction of:
Disposal Field Septic Tank Holding Tank Privy
Non-Public
Water Well Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method.
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
11/14/2025
10/17/2026
FORGE ENGINEERING
Special Provisions: The current disposal field is located inside the required 100-ft well radius for Lot 11. Please
note that this will need to be resolved during any future COSA application.
Expiration Date:
þ þ ¨¨¨¨
Issued To:
Issued By:
Date:
Date:
11/14/2025
11/14/2025
FORGE ENGINEERING
Isatou B Njie
MUNICIPALITY OF ANCHORAGE
On-Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On-Site Wastewater Disposal System Permit
October 16, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Susitna View Estates, Block 3 Lot 1 – 17030 Aries Court
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot has a 3 -bedroom home on the property that has an aging septic system,
so we are submitting this permit application for the construction of a new septic system. The
attached site plan identifies the location of the home as well as the well & new septic location. No
conflicts exist between this proposed system and any other well or septic system, whether on this
lot or adjacent lots.
The ground surface on the lot slopes toward the west steeply near the west side of the house, but
there is an area that is milder. It is in that flatter area that the new septic system is located. There
are slopes greater than 25% within 50 feet downslope of the primary site, so please see slopes
analysis. Contours are shown on the site plan showing the grade and direction of flow. Stormwater
drainage will not impact this septic system. The new trench will be constructed parallel to the slope
as much as possible. The client has replumbed the interior of the building to where the connection
will be on the east side of the house.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached
test hole log, plan and profile pages for the septic design. If this design is followed, there will be
no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251383, Isatou Njie, 11/14/25
500
EXISTING WELL
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=40'
25' LONG x 3' WIDE, 8'
EFFECTIVE DEPTH
ABSORPTION TRENCH
WELL RADIUS NEEDS
TO BE STAKED AT TIME
OF INSTALLATION
NEW 1000-GAL TANK
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
2CO
MT
TH#1
SUSITNA VIEW ESTATES, BLOCK 3 LOT 1
FEET
0 40 80
FCO
SEPTIC AND WELL
NOT IN VIEW PORT
SEPTIC PLAN
10/16/25
CO
ARIE
S
C
O
U
R
T
FE
O
D
O
S
I
A
D
R
3-BDRM HOME
430
420
425
420
415
410405
400
395
390
385
EXISTING 1000-GAL
TANK TO BE
DECOMMISSIONED
EXISTING ABSORPTION
TRENCH
CONNECT TO NEW
SEPTIC SERVICE
PIPE & INSTALL A
NEW FCO
ABANDON OLD
SEPTIC SERVICE
LINE
SEPTIC AND WELL
NOT IN VIEW PORT
SEPTIC AND WELL
NOT IN VIEW PORT
SEPTIC NOT IN
VIEW PORT
EXISTING WELL
MT
CO
EXISTING 100'
WELL RADIUS
FOR LOT 11
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251383, Isatou Njie, 11/14/25
SUSITNA VIEW EST, BLOCK 3 LOT 1
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
3'
6"
2'-6"
8'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: 5 MIN/IN
APPLICATION RATE: 1.2 GPD/SF
8.0' DEEP TRENCH SYSTEM
1000-GAL SEPTIC TANK
BOTTOM OF TRENCH: 11.0' BELOW GRADE
FLOW LINE ELEVATION: 3.0' BELOW GRADE
450 GPD / 1.2 GPD/SF / 8' DEEP / 2 SIDES = 23.4 LF TRENCH REQUIRED (25.0 LF SPECIFIED)
GEOTEXTILE FABRIC
6"
10/16/25
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251383, Isatou Njie, 11/14/25
390.00
395.00
400.00
405.00
410.00
415.00
420.00
425.00
390.00
400.00
410.00
420.00
0+00.00 0+50.00 0+83.00
1"=10'
SLOPE CROSS SECTION
SEPTIC TRENCH
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
46%
AN
G
LE OF EF
FLUE
N
T
INF
L
U
E
N
C
E
3:1 MAX SLOPES
FEET
0 10 20
10/16/25
SUSITNA VIEW ESTATES, BLOCK 3 LOT 1
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251383, Isatou Njie, 11/14/25
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING
5
9/23/25 1
2
3
5
6GM (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
SUSITNA VIEW EST BLOCK 3 LOT 1
9/23/25 020-0913-40
BILL NEITHERCOAT
93 8
16
OB
29
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: JARED E
99 8
16
NONE
10/1/25
COMMENTS:
SITE PLAN
6"
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED.
10/1/25
MOISTURE NOTED AT TIME OF DIGGING?NONE
93 8
1630 99 8
16 6"
93 8
1630 99 8
16 6"
4
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251383, Isatou Njie, 11/14/25
FE
O
D
O
S
I
A
D
R
I
V
E
ARIES
C
O
U
R
T
SUSIT
N
A
V
I
E
W
ESTAT
E
S
SUBD
I
V
I
S
O
N
BLOC
K
3
Taylor L. Dosch
No. 189892
R
E
GISTEREDPROFESSIO N A L L A N D S U RVEYOR
Well Drilling Permit Number: SW_ Date of Issue:
Parcel Identification Number:_
Legal Description Property Owner Name e & Address:
.S vs j 0. V I�i ' L✓ E' s7- n r'( I /up 1) 9 I c 06L4
l 70, 14 &t � r e s < - F •Q 1-s- !I
Pump Installation Date: 310, j .Z 0 t3
Pump Intake Depth Below Top of Well Casing: 22 d feet
Pump Manufacturer's Name: .1 u cf«-E
Pump Model: 7 S C 2 1 FS l
Pump Size 31V hp
Pitless Adapter Burial Depth: to feet
Pitless Adapter Manufacturer's Name:
Pitless Adapter Installer:
Well Disinfected Upon Completion': xYes ❑ No
Method of Disinfection:
Comments:. a
Anchorage Pump & Well Servi6e
Pump Installer Name: 330 East 76th Avenue
Anchorage, Alaska 99618
Phone: 907-243-0740
Fax: 907-243-0742
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
neat
tjevelBuil nt Services Department
_ \
2uiid:ng Safety Civisioii
b
Or, -Site 'r atcr I& Wastewater Fr'ogr _m,
4700 Brogow Street
P.O. Sox 19.5650
Mark Begich
Anchoroge, .4K 99519-6650
Mayor
na.muni. ,rg, onsite
(907)343-790}
Pump Installation Log
Well Drilling Permit Number: SW_ Date of Issue:
Parcel Identification Number:_
Legal Description Property Owner Name e & Address:
.S vs j 0. V I�i ' L✓ E' s7- n r'( I /up 1) 9 I c 06L4
l 70, 14 &t � r e s < - F •Q 1-s- !I
Pump Installation Date: 310, j .Z 0 t3
Pump Intake Depth Below Top of Well Casing: 22 d feet
Pump Manufacturer's Name: .1 u cf«-E
Pump Model: 7 S C 2 1 FS l
Pump Size 31V hp
Pitless Adapter Burial Depth: to feet
Pitless Adapter Manufacturer's Name:
Pitless Adapter Installer:
Well Disinfected Upon Completion': xYes ❑ No
Method of Disinfection:
Comments:. a
Anchorage Pump & Well Servi6e
Pump Installer Name: 330 East 76th Avenue
Anchorage, Alaska 99618
Phone: 907-243-0740
Fax: 907-243-0742
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
MUNICIPALITY OF ANCUUHAUZ
Hea h and Environmental Prote on
Fourth Floor West
825 L Street
Anchorage, Alaska 99501
279-2511, x 224, 225
ffJ5PECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM — -----
----- -----
_� _`_F
---. NON
NAME ADDRESS PADDRESS
LOCATION Q , � _70( LEGAL DESCRIPTION--
SEPTIC
ESCRIPTION_
SEPTIC TANK
DISTANCE�) __ MANUFACTURER _TF RIAL
FROM WELL _W-/� _
INSIDE LENGTH_` - — INSIDE WIDI"H LIOUID DEPTH -__ LIQUID CAPACITY / GALLONS.
T1t_4-=D--FEL-D: "TOTAL LENGTHPk
/
c>- .-OF LINE __--
.___FOUN._. -._ _ _-NEAREST LOF LINE _ --
DISTANCE FROM WELL L6�- DATION//
Of Lines ----, --- DISTANCE_ BEIWF_EN LINES __._4 -./4 --TRENCH WIDT3A6_ IN. TOTAL EFFECTIVE
ABSORPTION AREA __�__�---- "—�- SQ FT. LENGTH OF EACU LINE
I DEPTH OF I II ILR
DEPTH: TOP OF TILE 10 FINISH GRADE _ +�----NATERIAI_ BENEATH FILE .._.-"-----IN. ABOVE TILE �° _ _IN.
NUMBER OF
COMPARTMENTS �y
SEEPAGE PIT:
DIAMETER ____OR WIDTH--_ LLNGFFI_—,
DEPTH--
Log
EPTH_Log Crib _Rings_ Crib Size: DIAMETER_--ADISTANCE FROM:
TOTLEFFECTIVE
ABSORPTION BUILDING FOUNDATION.--. NEAREST LOT LINE ION AREA (WALL AREA;
Well
Class: _ - Depth:
Well Distance To: Lot Line Lo I'
Bldg: Ap I_,-.-- Sewer -� Line: _^
Pipe Mater lals :1.,�jx, itiSTM 6
S of Bedrooms: _
Installer:
Remarks:
I
i
WELL
FT.
DATE .9` '_*31 APPROVED
DEPA IMENf`� HF - ALT H AND ENV IRONt•TENI-K, R4�' �
R�1 �� (�
n _'jlO E. 'TUDOR FD.. FINi HO?21fit�E, Nk::.
.2�.�
F'EI'.'T:f'T tdiJ, r' 75 ? i nn -
aANCHORAGE
n l�la� �l •lei l t�
.,. r•
HFF'L_IL_HNT E:ILL_ tdEl"I'HERI OHi 1._Git=i s"i_t.!Hf:`.(i FEET
I_.00:H'I .T.Ota HF:IES �: T DR _ LOT .`_:S'r,:.E:
I 1..ECiFII L_ 9. k. ._
:_di_ITNFi VIEW EST
I-f';F'E OF '.`•Lila Ht,.,UF:BI'IIIPd'
t•THi<;It9iJt'1 tJUi4E:EF: OF BE'DROCtI''Is =
SOIL RATING (SQ FT/B')=
k:L:G?i!af EU SIZE OF IHE SOIL ABSORPTION SYSTEM IS:
I'1iE
FEET:$ OF THE
OR
1 N
THLE
HE C�EFGT'HHitFItiF7F:Ef CaH1iiRfHE LENGTH PITIf�THE';C Iti1"ft dt:E E:E"fWEEFai 'THE HLIRFHi FHOF} "1"tlEf'
G1=:OUND Arx, THE BOTIOq OF THE EXCAVATION (IN FEET').
THERE IS NO SET WID"fH FOR TRENCHES.l L. BETWEEN THE OUTFALL PIPE.
T'HE GRFiVEL DEPTH I THE MINIMUM DEPTH OF Gk:H•r
Ht-AD "(HE BOTTOM OF THE EXGAVRTION CIN FEET). -A ._
:fF'"' 7L a "-F"P•F1 3. M F= j-e�-�
�ya e
BHC gj :L"-4"-�"EM WITHOUT- FINAL INSPECTION AND APPROVAL B THIS
FILLING OF HYJ;
DEPART11ENT WILL. BE :_•UB-tEC7 TO F'RCiSF_'l.tJllOtd.
t4):PJIMUYJ C: :I:`_"f'fihdCE BETWEEN H WELL AND ANY ON-SITE SEWAGE DISPOSAL_ S';SI Y
1-00 FEET FOR H Pk:JVATE 14E'LL OR 200 FEET FOR A PUBLIC: WELL..
_F'ECIFIC:HTIOt-TS FIND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO It�_URE PROPER
INST'HLLH"f ION. F__�F' ::
F ` E=_ F=' rep :9 ° e-' FF !._ tl ^� g _=:_
I AM FAMILIAR
WITH
HL THE
REGIUI EMENG'S FOR ON-SITE SEWERS AND WELLS FIS
;
I CER I IF4' IHH"f
2: 1H E°T THE SYSTEM IN ACCORDANCE WITH THE CODES. I yFi
w'
1. tJIL.i_ ].Pa_"IHLL. T}IF: Y'S.
-( IItJDEF:S`1'HP•dl) 1'HtiT THE Citd-SI1E SEWER _.r��fEt'1 t'1F1'; k:EC!I_IIF*:E EPdI._FiF'..I:vt-'t'TEtJT
RESIDENCE I_: REMODELED "I"i_t INCLUDE MORE "MHN BEDROOMS.
i
SIGtdEI>:191� -
HPPLIC:R dT BILL/L�NEEIT Eh'CiiH"( / %s
o
'mak"-
ISSUED By
N o 4 i
We'to ql.R�,s\c_� /() �;()e i I so;ls 1`5 txsK
(70)2,,tauetion Sreit -fal
"One test is worth a thousand opinions"
2204 Cleveland Anchorage, Alaska 99503
Performed For 8i�� NePr6j Date Performed S -Lb-%(
Lenal oescrintion: Lot_jBloc4:_21_Subdivision.3uey2 _/E ,E/ rArCj
This Form Reports Soils Loq 1 Los Percolation Test_
tenth
Feet Soil Characteristics
a
2 — 715P S
4 - (2 LeiaN 6x64"(11 Slim]
6— CSP-
8-
10 —
13 ".NM4—
14_.
16
18— a0H
20—
Was Ground Water Encountered? ((Q
If Yes, At what Denth?
No Behack EN[ouNrE'AEP
����
1N=1;
-
Readinq Date Gross Time Net Time Depth to H2O Net Dron'
'r—
Percolation Rate Minute
Proposed Installation: Seenaae Pit Drain Field
Deoth of Inlet Depth ToBottom Of Pi�t�OF Trench
CO WAENTS: �2�t" �T�Z k
Test Performed By .TQM Data Certified By: `cou; 05 /�%I�
Date:
IFs n L_ I "r W ®: e F= r r -J r_ 8-9 r_e Q
DEPARTMENT OF HEALTH ARID ENVIRONMENTAL PROTECTION
2510 E. TUDOR RD., ANCHORAGE, AK 99507
276-2221
wF:rt_L F='EFRt-1 I T"
PERMIT NO. ( 76188 )
APPLICANT WILLIAM J NEITHERCOAT -IlreflOX X94 2714-1o�75
LOCATION ARIES COURT lxy D-°"oMe
LEGAL L1 E3 SUSITNA VIEW LOT SIZE SQUARE FEET
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL.
WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS
OF THE WELL COMPLETION.
SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER
INSTALLATION.
F=°EF;a'M I T 'w AL I G� F �e �t !E ar°EH�_ F iarrl I:E;S3UFE
I CERTIFY THAT
1: 1 AM FAMILIAR WITH THE REQUIREMENTS FOR.. ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
—_
SIGNEp. _ �kLL.M
_ �_______
APPLICANT ^4L J NEITHERCOAT III
ISSUED
B - --------- DATE
--------DATE / t
M -W DRILLING, Inc. `
P. O. Box 4-1224 • 1310C International Airport Road
(907)274-4611
ANCHORAGE, ALASKA 99509
DRILLING LOG
Well Owner w1i•;i.;l_:>_dl(; iV_ J: Ghl Use of Well
Location (address of: Township, Range, Section, if known; or distance main road
-
J, -t, T.1:. So'. _Jtna
Size of casing 2" Depth of Hole 263 feet Cased to 65 22 feet
Static water level GO? ft. (abo've),� (below) land surface. Finish of well (check one) open end
Screen ( ); Perforated ( ).
Describe screen or perforation
Well pumping test at gallons per (1011f) (minute) for 1- - hours with 1 C 0°< ft.
of drawdown from static level.
Date of completion—_30 ';1"Y t of c)
WELL LOG
Depth in feet from
ground surface Give details of formations penetrated, size of material, color and hardness
TO _S
TO 62
?50
To
" 30 TO 2r..
4' i 11:�r Cit �.v�:1 ° Occ c:olil;t es
}�C'EivCJf �s CV'iI \i: C -T c •:pl: 1 i nCiar. r.
i3rstl :r(�<1, n �r
NWWA Certified Contractor
nvu�` - wT A7 d R- 0Tj
2 —STATE