Loading...
HomeMy WebLinkAboutSUSITNA VIEW ESTATES BLK 3 LT 15ustTt:A M LST Permit Number:OSP251383 Tax Code Number:02009134000 Work Type:Septic Upgrade Effective Date: Design Engineer: Site Legal Address:SUSITNA VIEW ESTATES BLK 3 LT 1 G:3336 Owner:NEITHERCOAT WILLIAM J III Site Mailing Address:17030 ARIES CT, Anchorage Lot Size in Sq Ft:21301 Total Bedrooms:3 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 11/14/2025 10/17/2026 FORGE ENGINEERING Special Provisions: The current disposal field is located inside the required 100-ft well radius for Lot 11. Please note that this will need to be resolved during any future COSA application. Expiration Date: þ þ ¨¨¨¨ Issued To: Issued By: Date: Date: 11/14/2025 11/14/2025 FORGE ENGINEERING Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Wastewater Disposal System Permit October 16, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Susitna View Estates, Block 3 Lot 1 – 17030 Aries Court Septic system design Dear On-Site Services Engineer: The owner of the above lot has a 3 -bedroom home on the property that has an aging septic system, so we are submitting this permit application for the construction of a new septic system. The attached site plan identifies the location of the home as well as the well & new septic location. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the west steeply near the west side of the house, but there is an area that is milder. It is in that flatter area that the new septic system is located. There are slopes greater than 25% within 50 feet downslope of the primary site, so please see slopes analysis. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The client has replumbed the interior of the building to where the connection will be on the east side of the house. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251383, Isatou Njie, 11/14/25 500 EXISTING WELL Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=40' 25' LONG x 3' WIDE, 8' EFFECTIVE DEPTH ABSORPTION TRENCH WELL RADIUS NEEDS TO BE STAKED AT TIME OF INSTALLATION NEW 1000-GAL TANK CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2CO MT TH#1 SUSITNA VIEW ESTATES, BLOCK 3 LOT 1 FEET 0 40 80 FCO SEPTIC AND WELL NOT IN VIEW PORT SEPTIC PLAN 10/16/25 CO ARIE S C O U R T FE O D O S I A D R 3-BDRM HOME 430 420 425 420 415 410405 400 395 390 385 EXISTING 1000-GAL TANK TO BE DECOMMISSIONED EXISTING ABSORPTION TRENCH CONNECT TO NEW SEPTIC SERVICE PIPE & INSTALL A NEW FCO ABANDON OLD SEPTIC SERVICE LINE SEPTIC AND WELL NOT IN VIEW PORT SEPTIC AND WELL NOT IN VIEW PORT SEPTIC NOT IN VIEW PORT EXISTING WELL MT CO EXISTING 100' WELL RADIUS FOR LOT 11 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251383, Isatou Njie, 11/14/25 SUSITNA VIEW EST, BLOCK 3 LOT 1 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 2'-6" 8' DESIGN FACTORS:SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 5 MIN/IN APPLICATION RATE: 1.2 GPD/SF 8.0' DEEP TRENCH SYSTEM 1000-GAL SEPTIC TANK BOTTOM OF TRENCH: 11.0' BELOW GRADE FLOW LINE ELEVATION: 3.0' BELOW GRADE 450 GPD / 1.2 GPD/SF / 8' DEEP / 2 SIDES = 23.4 LF TRENCH REQUIRED (25.0 LF SPECIFIED) GEOTEXTILE FABRIC 6" 10/16/25 PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251383, Isatou Njie, 11/14/25 390.00 395.00 400.00 405.00 410.00 415.00 420.00 425.00 390.00 400.00 410.00 420.00 0+00.00 0+50.00 0+83.00 1"=10' SLOPE CROSS SECTION SEPTIC TRENCH Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 46% AN G LE OF EF FLUE N T INF L U E N C E 3:1 MAX SLOPES FEET 0 10 20 10/16/25 SUSITNA VIEW ESTATES, BLOCK 3 LOT 1 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251383, Isatou Njie, 11/14/25 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING 5 9/23/25 1 2 3 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: SUSITNA VIEW EST BLOCK 3 LOT 1 9/23/25 020-0913-40 BILL NEITHERCOAT 93 8 16 OB 29 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JARED E 99 8 16 NONE 10/1/25 COMMENTS: SITE PLAN 6" USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED. 10/1/25 MOISTURE NOTED AT TIME OF DIGGING?NONE 93 8 1630 99 8 16 6" 93 8 1630 99 8 16 6" 4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251383, Isatou Njie, 11/14/25 FE O D O S I A D R I V E ARIES C O U R T SUSIT N A V I E W ESTAT E S SUBD I V I S O N BLOC K 3 Taylor L. Dosch No. 189892 R E GISTEREDPROFESSIO N A L L A N D S U RVEYOR Well Drilling Permit Number: SW_ Date of Issue: Parcel Identification Number:_ Legal Description Property Owner Name e & Address: .S vs j 0. V I�i ' L✓ E' s7- n r'( I /up 1) 9 I c 06L4 l 70, 14 &t � r e s < - F •Q 1-s- !I Pump Installation Date: 310, j .Z 0 t3 Pump Intake Depth Below Top of Well Casing: 22 d feet Pump Manufacturer's Name: .1 u cf«-E Pump Model: 7 S C 2 1 FS l Pump Size 31V hp Pitless Adapter Burial Depth: to feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: Well Disinfected Upon Completion': xYes ❑ No Method of Disinfection: Comments:. a Anchorage Pump & Well Servi6e Pump Installer Name: 330 East 76th Avenue Anchorage, Alaska 99618 Phone: 907-243-0740 Fax: 907-243-0742 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. neat tjevelBuil nt Services Department _ \ 2uiid:ng Safety Civisioii b Or, -Site 'r atcr I& Wastewater Fr'ogr _m, 4700 Brogow Street P.O. Sox 19.5650 Mark Begich Anchoroge, .4K 99519-6650 Mayor na.muni. ,rg, onsite (907)343-790} Pump Installation Log Well Drilling Permit Number: SW_ Date of Issue: Parcel Identification Number:_ Legal Description Property Owner Name e & Address: .S vs j 0. V I�i ' L✓ E' s7- n r'( I /up 1) 9 I c 06L4 l 70, 14 &t � r e s < - F •Q 1-s- !I Pump Installation Date: 310, j .Z 0 t3 Pump Intake Depth Below Top of Well Casing: 22 d feet Pump Manufacturer's Name: .1 u cf«-E Pump Model: 7 S C 2 1 FS l Pump Size 31V hp Pitless Adapter Burial Depth: to feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: Well Disinfected Upon Completion': xYes ❑ No Method of Disinfection: Comments:. a Anchorage Pump & Well Servi6e Pump Installer Name: 330 East 76th Avenue Anchorage, Alaska 99618 Phone: 907-243-0740 Fax: 907-243-0742 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCUUHAUZ Hea h and Environmental Prote on Fourth Floor West 825 L Street Anchorage, Alaska 99501 279-2511, x 224, 225 ffJ5PECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM — ----- ----- ----- _� _`_F ---. NON NAME ADDRESS PADDRESS LOCATION Q , � _70( LEGAL DESCRIPTION-- SEPTIC ESCRIPTION_ SEPTIC TANK DISTANCE�) __ MANUFACTURER _TF RIAL FROM WELL _W-/� _ INSIDE LENGTH_` - — INSIDE WIDI"H LIOUID DEPTH -__ LIQUID CAPACITY / GALLONS. T1t_4-=D--FEL-D: "TOTAL LENGTHPk / c>- .-OF LINE __-- .___FOUN._. -._ _ _-NEAREST LOF LINE _ -- DISTANCE FROM WELL L6�- DATION// Of Lines ----, --- DISTANCE_ BEIWF_EN LINES __._4 -./4 --TRENCH WIDT3A6_ IN. TOTAL EFFECTIVE ABSORPTION AREA __�__�---- "—�- SQ FT. LENGTH OF EACU LINE I DEPTH OF I II ILR DEPTH: TOP OF TILE 10 FINISH GRADE _ +�----NATERIAI_ BENEATH FILE .._.-"-----IN. ABOVE TILE �° _ _IN. NUMBER OF COMPARTMENTS �y SEEPAGE PIT: DIAMETER ____OR WIDTH--_ LLNGFFI_—, DEPTH-- Log EPTH_Log Crib _Rings_ Crib Size: DIAMETER_--ADISTANCE FROM: TOTLEFFECTIVE ABSORPTION BUILDING FOUNDATION.--. NEAREST LOT LINE ION AREA (WALL AREA; Well Class: _ - Depth: Well Distance To: Lot Line Lo I' Bldg: Ap I_,-.-- Sewer -� Line: _^ Pipe Mater lals :1.,�jx, itiSTM 6 S of Bedrooms: _ Installer: Remarks: I i WELL FT. DATE .9` '_*31 APPROVED DEPA IMENf`� HF - ALT H AND ENV IRONt•TENI-K, R4�' � R�1 �� (� n _'jlO E. 'TUDOR FD.. FINi HO?21fit�E, Nk::. .2�.� F'EI'.'T:f'T tdiJ, r' 75 ? i nn - aANCHORAGE n l�la� �l •lei l t� .,. r• HFF'L_IL_HNT E:ILL_ tdEl"I'HERI OHi 1._Git=i s"i_t.!Hf:`.(i FEET I_.00:H'I .T.Ota HF:IES �: T DR _ LOT .`_:S'r,:.E: I 1..ECiFII L_ 9. k. ._ :_di_ITNFi VIEW EST I-f';F'E OF '.`•Lila Ht,.,UF:BI'IIIPd' t•THi<;It9iJt'1 tJUi4E:EF: OF BE'DROCtI''Is = SOIL RATING (SQ FT/B')= k:L:G?i!af EU SIZE OF IHE SOIL ABSORPTION SYSTEM IS: I'1iE FEET:$ OF THE OR 1 N THLE HE C�EFGT'HHitFItiF7F:Ef CaH1iiRfHE LENGTH PITIf�THE';C Iti1"ft dt:E E:E"fWEEFai 'THE HLIRFHi FHOF} "1"tlEf' G1=:OUND Arx, THE BOTIOq OF THE EXCAVATION (IN FEET'). THERE IS NO SET WID"fH FOR TRENCHES.l L. BETWEEN THE OUTFALL PIPE. T'HE GRFiVEL DEPTH I THE MINIMUM DEPTH OF Gk:H•r Ht-AD "(HE BOTTOM OF THE EXGAVRTION CIN FEET). -A ._ :fF'"' 7L a "-F"P•F1 3. M F= j-e�-� �ya e BHC gj :L"-4"-�"EM WITHOUT- FINAL INSPECTION AND APPROVAL B THIS FILLING OF HYJ; DEPART11ENT WILL. BE :_•UB-tEC7 TO F'RCiSF_'l.tJllOtd. t4):PJIMUYJ C: :I:`_"f'fihdCE BETWEEN H WELL AND ANY ON-SITE SEWAGE DISPOSAL_ S';SI Y 1-00 FEET FOR H Pk:JVATE 14E'LL OR 200 FEET FOR A PUBLIC: WELL.. _F'ECIFIC:HTIOt-TS FIND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO It�_URE PROPER INST'HLLH"f ION. F__�F' :: F ` E=_ F=' rep :9 ° e-' FF !._ tl ^� g _=:_ I AM FAMILIAR WITH HL THE REGIUI EMENG'S FOR ON-SITE SEWERS AND WELLS FIS ; I CER I IF4' IHH"f 2: 1H E°T THE SYSTEM IN ACCORDANCE WITH THE CODES. I yFi w' 1. tJIL.i_ ].Pa_"IHLL. T}IF: Y'S. -( IItJDEF:S`1'HP•dl) 1'HtiT THE Citd-SI1E SEWER _.r��fEt'1 t'1F1'; k:EC!I_IIF*:E EPdI._FiF'..I:vt-'t'TEtJT RESIDENCE I_: REMODELED "I"i_t INCLUDE MORE "MHN BEDROOMS. i SIGtdEI>:191� - HPPLIC:R dT BILL/L�NEEIT Eh'CiiH"( / %s o 'mak"- ISSUED By ­ N o 4 i We'to ql.R�,s\c_� ­/() �;()e i I so;ls 1`5 txsK (70)2,,tauetion Sreit -fal "One test is worth a thousand opinions" 2204 Cleveland Anchorage, Alaska 99503 Performed For 8i�� NePr6j Date Performed S -Lb-%( Lenal oescrintion: Lot_jBloc4:_21_Subdivision.3uey2 _/E ,E/ rArCj This Form Reports Soils Loq 1 Los Percolation Test_ tenth Feet Soil Characteristics a 2 — 715P S 4 - (2 LeiaN 6x64"(11 Slim] 6— CSP- 8- 10 — 13 ".NM4— 14_. 16 18— a0H 20— Was Ground Water Encountered? ((Q If Yes, At what Denth? No Behack EN[ouNrE'AEP ���� 1N=1; - Readinq Date Gross Time Net Time Depth to H2O Net Dron' 'r— Percolation Rate Minute Proposed Installation: Seenaae Pit Drain Field Deoth of Inlet Depth ToBottom Of Pi�t�OF Trench CO WAENTS: �2�t" �T�Z k Test Performed By .TQM Data Certified By: `cou; 05 /�%I� Date: IFs n L_ I "r W ®: e F= r r -J r_ 8-9 r_e Q DEPARTMENT OF HEALTH ARID ENVIRONMENTAL PROTECTION 2510 E. TUDOR RD., ANCHORAGE, AK 99507 276-2221 wF:rt_L F='EFRt-1 I T" PERMIT NO. ( 76188 ) APPLICANT WILLIAM J NEITHERCOAT -IlreflOX X94 2714-1o�75 LOCATION ARIES COURT lxy D-°"oMe LEGAL L1 E3 SUSITNA VIEW LOT SIZE SQUARE FEET MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F=°EF;a'M I T 'w AL I G� F �e �t !E ar°EH�_ F iarrl I:E;S3UFE I CERTIFY THAT 1: 1 AM FAMILIAR WITH THE REQUIREMENTS FOR.. ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. —_ SIGNEp. _ �kLL.M _ �_______ APPLICANT ^4L J NEITHERCOAT III ISSUED B - --------- DATE --------DATE / t M -W DRILLING, Inc. ` P. O. Box 4-1224 • 1310C International Airport Road (907)274-4611 ANCHORAGE, ALASKA 99509 DRILLING LOG Well Owner w1i•;i.;l_:>_dl(; iV_ J: Ghl Use of Well Location (address of: Township, Range, Section, if known; or distance main road - J, -t, T.1:. So'. _Jtna Size of casing 2" Depth of Hole 263 feet Cased to 65 22 feet Static water level GO? ft. (abo've),� (below) land surface. Finish of well (check one) open end Screen ( ); Perforated ( ). Describe screen or perforation Well pumping test at gallons per (1011f) (minute) for 1- - hours with 1 C 0°< ft. of drawdown from static level. Date of completion—_30 ';1"Y t of c) WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness TO _S TO 62 ?50 To " 30 TO 2r.. 4' i 11:�r Cit �.v�:1 ° Occ c:olil;t es }�C'EivCJf �s CV'iI \i: C -T c •:pl: 1 i nCiar. r. i3rstl :r(�<1, n �r NWWA Certified Contractor nvu�` - wT A7 d R- 0Tj 2 —STATE