Loading...
HomeMy WebLinkAboutSUSITNA VIEW ESTATES BLK 3 LT 8  ("'~ J MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME [~HON: ~NEW MAILING ADDRESS~ LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS  Manufacturer Material No. of co~artmants Liq. capacity in gallons Inside length Width Liquid depth l/ O0 0 ~F HOMEMADE: O Z ~ Manufacturer Material Liquid capacitv in gallons D Well , Foundation Nearest lot lin PE ~ ~ g % ~ ~ } Distance bet=een lines ~ No. oflines e gtho each ine , ~: Total length lice} Trench Length Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption erea ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. m Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING ' ' REMARKS 72-013 (Rev. 3/78) DEPARTMENT GF HEAL. I'H AND ENV~:RONMENTAL F:'RGTECTIC)N 825 L S]"REET, ANCHORAGE.. Al-,:: 99501 264.--z1.~20 PERMIT NO: DATE ISSUED: 84()753~ 09/06/84 APPLICANT: ADDRESS: CONTACT PHONE: MARILYN SCARBGROUGH 17001 ARIES COURT ANCHORAGE, AK 99516 345-0069 LEGAL DESCRIP: GLIBDIVISIGN: SUSITNA VIEW LO]': 8 SECTION: 3 TOWNSHIP: liN RANGI.-T.: 3W LOT SIZE: 27225 (SQ.F'T. OR ACRE:S) MAX BEDRGOMS: 3 BLOCK: L. ist~d belew a~-e the options avai].abie 'Lo you in des:iDning your' sep'Lic system. Choose the option that best £it~ yrjup site. ][- IF:ii ES: ~,~ ~TZ ~-~ DEPTH "FO PIF'E BOTTOM (FT.) 4,,0 4.0 GRAVEL DEP]'H (FT.) 5.5 3,,5 TOTAL DEPTH (FT.) 9,,5 7.5 GRAVEl._ WIDTH (FT.) 2.5 5.0 GRAVEL LENGTH (FT.) 38~0 ~5.0 GRAVEl_ VOLOME (CU.YDS.) 21 2 '=~' 4 TANK SIZ{ (GALS) 1~)00.0 ~'~ 1~0[)0.0 SOIL RATING (SO.FT. /BR) 138 138 TANK MUST HAVE{ AT LEAST TWO CO~IPARTMENTS .3 t ce['ti{y that: 1, I am {amiliap with the r'equipements £of on-site seweps and wells a~z set ¢opth by the Municipality o~ Anchorage (MOA) and [he State e~' Alaska. I will instal 1 the system in acco~-danc:e ~ith ail MOA c:odes and ~egutati~ns, and in compliance with the design cpitepia o~' this pepmit 3. I will adher'e to ~/ll MOA and State o¢ Alaska pequi~-ements fo~. the set back distances ¢*-om any exieting we] l, wastewater' disposal, system o~~ pub].:i.c sewed-age sys'Lem on this op any adjacent op near'by lot. 4. I under'stand that this pepmi't is vaIid ¢o~' a maximum of' 3 bedr'ooms and a~:y enlapgemen{ will. pec]uipe an additional pepmi{. IF A LIFT STATION ~S INSTALLED IN AN AREA COVERED BY MOA BUILDING []ODES, THEN (1) AN ELECTRICAL F'ERMI-r AND INSPECTION MUST BE OBTAINED: (;2) AG-BUtL]'S WILL NOT BE AF'PROVED WITHOGT AN EI..ECTF~ICAL INSF'ECTIGN REF:'GRT~ AND (3) ELECTRICAL WORk: MUST BE DGNE BY A LICENSED ELECTRICIAN, DEPART~IENT OF HEALTH AND ENVIRONMENTAL P,~OTECTIOI'4C' ' - ' 825 L STFcEET, ANCHORAGE, AK 995] ~ 264-4720 PERMIT NO: 8-..75.: DATE ISSUED: 09/06/G4 A~PLICANT: ABDRESS: CONTACT F'HONE: MARILYN SCARBGROUGH 17001 ARIES COURT ANCHORAGE,, Al'{ 99516 · ];45-0 }69 LEGAL. DESCRIP: SUBI)IVtSIOW: SUSITNA VIEW SECTION: 3 TOWNSHIP: LOT SIZE: 27225 (SQ.FT. OR ACRES) MAX BEDROOMS: 3 LOT: t3 BL.O...I.. '~' 1 :tN F;:ANGE: .].;W Listed below are the options avaiIable to system. Choose the option that best £i'Ls DEP]'H TO PIPE BOTTOM (FT.) GRAVEl_ DEPTH (FT.) TOTAL DEPTH (FT.) GRAVEl.. WIBTH (FT,) GRAVEL LENGTH (FT.) GRAVEL VOLtJME (CU. YDS.) TANI< SIZE (GALS) SOIl_ RATING (SQ.FT. /BR) you in designing your' septic your site. 3.0 2.5 5,,5 5.0 55.0 '29.5 1,000.0 '~'~ 1258 5 5 0 .~ 1 %% DEPTH TO ='IPE BOTTOM < 3.5 PT. REQUIRES INSULATION DEPTH TO :'IPE BOTTOM < 4.0 FT. MAY REQUIRE A LIFT STATION GRAVEL LENGTH > 75 FT. REQUIRES MULTIPLE RUNS (NOT EXCEEDING 75 FT. EACH) TANK MGST HAVE AT LEAST TWO COMPARTMENTS I certi£y that: 1. I ar. Camiliar with the r'equirem~nts For on-site sewers and wells a~s set £orth by the Municipality of Anchorage (MOA) 6end the Gtate oF Alaska. I will install the system in accordance with all MOA codes and r'egulations, and z~ compliance witP the 'design criteria o£ this per'mit. 3. I will adhere to all MGA and State o£ Alaska requir-ements for the set bacl.:: distances £rom any e>.'isting well, wastewatep disposal system or publ:i.c sewerage system on this or any adjac:ent or' nearby tot. 4. I understand that this oermit is valid £or a maxzmum o£ 3 bedrooms and any enlargement will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY I'IOA THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; WILL_ ~40T BE APF'ROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; ELECTRICAL WORK MUST 8E DONE BY P LICENSED ELECTRICIAN. SIGNED APPLICANT: ISSUED BY BIJILDING CdDE=~, (2.) Al'ID (3) THE 'ALASKA e T¢lROnlllenTAL CONTROL seRVices, inc. ~n§ineerin9 6 I~nuironmenl~l $1urlies 5epterrber 1~, 1984 Department of Health and Environmental Protection 825 L Street Anchorage, Alaska Attn: Susan Oswaldt MUNICIPALITY OF ANCHORAGE DF. PT, OF HF'ALTH & ENVI~oN/,AENTAL PROTECTION SE'P 9 1984 RECEIVED Subject: Lot 8 Block 5 Susitna View AEC5 made an slte evaluation of the subject property, to deterr~ne the available area for the on-slte septic system (diagram attached). The available area is over 100 feet from neighboring wells and greater than 30 feet from neighboring septic systems. The proposed system (perr~t #840753) requires a 5 foot wide drainfield, with 2.5 feet of gravel, and a total length of 53 feet. As evidenced by the attached diagram, it is unlikely that this system could be installed in the available area. The area is limited by the location of the house (north), the driveway (west), the bank and slope (east), and the south property line. The east bank is approximately 10-12 feet in height, and was establishedduring the excavation of the foundation. The driveway has been established and utilized, due to the slope, reconstruction of the driveway would involve major expense. The soil in this location could have been corRoacted due to traffic. To install an adequate system (in the area available) would require encroachment on the southern property line. Lot 9, the adjacent lot on the south, ls approximately 141.73 feet in width (n-s). The lot lfne between 8 and 9 ls platted at 167.22 feet. Ir~osing the system of lot 8 on the southern lot line would not restrict lot 9 from development. There is sufficient area to establish well, house, and septic system on lot 9 (area approximately 27,003 sq. ft.). The well on lot 8 has not been drllled at this tlme, the proposed well locatlon meets separation requirements from ~djacent systems. request.that a variance be granted, such that a septlc system could be znstalled on lot 8, but allowing sald system to encroach upon the south property line (within 10 feet of property i). Conditions for varzance: 1200 UJ¢$I 33rJ Aucnu¢, $ui1¢ ~ ,. Anchoro9¢. AI,ska 99503 .[907) 561-5040 i) New soils to be performed during the installation, such that an increased gravel depth (hence decreased length) might be possible, providing that modification of the permit design is practical and fulfills MOA requirements (i.e.-separation distance from groundwater and bedrock, valid soils test/perc, modification of design contingent upon soils ratings, etc. ). 2) Provisions mode such that the driveway does not interfere with the installation of the system or in~3ose on the system after installation. 3) Providing that redesign of the system moximize separation distance from the south property line. If this office can be of further assistance, please contact us at 561-5040. Approved: Sincerely, L. D. Montgomory ~// ALASKA ENV RON,~NTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue Suite B ANCHORAGE, ALASKA 99503 Phone 561-5040 SHEET NO. OF OHEOKED BY DATE SCALE / ,' 10 SI){ INCh WATER WELL DRILLED aND CASED OUT TO THE DEPTH OF _ 365 DRILLED AT ThE RATE OF $23.00 PEr FOOT. C/l~z~ ~o/~ 250 ~:; PROPERTY OWNER II'~,,~'~ $ca~o,~ou~v,A 355-0069 LOCATION OF WELL SITE. ~e DRILLER DEPT. OF HEALTH & ENVIRONM~:NTAL p.D. OTECTIC;~ WELL LOG: 0 .... 18' $.iJAa~ RECEIVED _pt,~e,: 720~,add..or~. On~ lto,z~e $~dl,,te. ?u~l~ ,~h.ou2A ,O¢ ,Dz.~.talZed 340 ;60 350 250 ~,t: $5750°00 COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID DRILLING. WRITE CHECK PAYABLE TO rAMPART DRILLING WORKS FOR THE SUM OF ~C;TqJ~ THANK YOU VERY MUCH. DATE. BERNIE CLAUS OF RAMPART DRILLING VqORKS SERVICE CHARGEOF 1Va% PER MONTH WILL BE ASSESSED ON PAST DUE ACCOUNTS.'-'~*~-~.., PERMIT NO. APPLICANT LOCATION LEGAL MARtLYN STOVERN SPA BOX 4004-I 99507 L8 B~ SUSITNR VIEW ESTATES LOT SIZE 276-58&± SQUARE FEE¥ TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MA)-~IMUM NUMBER OF BEDROOMS SOIL RATING (SQ FT/BR)= ±S0 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: 'C, EF'TH= L~. 5 LE~tGTH= ~--6 G~:~°.~'EL C:,EF"TH= 5. 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETHEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE ENCAVRTION (IN FEET). F-: E L----_~ L! i F.'E[:, SEF'T I C: TAP-~;:; S 1: ZE= ± £-~]-~---~ ,SRLLEiP-.~S PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TI--lO (2) BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION ~ND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS ±00 FEET FOR A PRIVATE WELL OR ±50 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL MINIMUM DISTANCE FROM R PRIVATE WELL TO R PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST 8E RETURNED TO THE DEPARTMENT WITHIN ~0 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'ERI'~ ~ 'T' E::<F' i RES [':-.E £:E~'-IBEF:.' ---~:1.. t9E:3: I CERTIFY THAT 1: t RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAS' REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN S BEDROOMS. V4. 0 POUCH 6-650 ANCIIORAGE, ALASKA 99502 06,~0 (907) 264-4111 ~Permit #: 820941 · January 31, 1983 TO: Permit Applicant Subject: Lot 8 Block 3 Susitna View Estates Subdivision A permit issued by this department for an individual well and/or on-site sewer system has expired as of December 31, 1982o Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log needs to be sent to this department for documentation of the installation date and to close the permit. If a private engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files and documentation. If there are any further questions, please call this office at 264-4720. Sincerel~ Robert C. Pratt, R.S. Acting Program Manager Sewer and Water Program RCP/ljw enc: Copy of Permit SWP/057 PERMIT NO. f.]Ll~ I C I" AL I T~' OF A~CH RAGE [ EF ARTMENT (~ HEALTH AND ENV IRONMENTRL '~,~OTECT I ON 825 ~L~ STREET, ANCHORAGE, AK. 9950t 264-4720 b]ELL A~D O~-~--SITE SEHER F°EF:~t IT ( 820D4~ ) APPLICANT LOCATION LEGAL MRRILYN STOVERN LBB~ SUSITNR VIEW ESTATES 5~5 IRWIN ST LOT SIZE 276-581± 999999 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS~ TRENCH MAXIMUM NUMBER OF BEDROOMS SOIL RATING (SQ FT?BR)= ±~0 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS~ C. EPTH= _'9-. 5 LEI'4GTH= _---a-S GRFi~?EL C-.EF'TH= 5. 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE E~CRVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE AND THE 80TTOM OF THE EXCAVATION (IN FEET). REQL! I F-:EC. SEPT I C TA~K-.' S I ZE= 100~-] GALLr_~S PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TWC~ (2) I~SPECTI~DF~S ARE REQLIlRED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR ~50 TO ~00 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO R PRIVATE SEWER LINE IS 25 FEET AND TO 8 COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN ~0 DR~S OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PER~4 I T E>(F' I RES [)ECE~IBEF.: I CERTIFY THAT l: I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN ~ BEDROOMS. APPLICANT~ MRRILb'N STOVERN ISSUED B --DATE--- V4.0 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTI:cTION SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST LEGAL DESCRIPTION: ~ .. - ~ ~-- 1 2 3 4 5 6 7 8 9 10 11 12 13- 14- 15 16 17 18 19- 20 OATE PERFORMED. WAS GROUND WATER S ENCOUNTERED? _ ?~ J'_~ ~ P E IF YES, AT WHAT DEPTH? SITE PLAN ~ ¢~.' OLATION RATE PERFORMED BY: /(~_ - - , CERTIFIED BY: • E 8V •tLc Municipality of Anchorage =�pJ On-Site Water and Wastewater Program "' al i " (907) 343-7904 SAFETY Certificate of On-Site Systems Approval Parcel I.D. 020-091-30 Expiration Date: 2 157-187 1. GENERAL INFORMATION: Complete legal description SUSITNA VIEW ESTATES; BLOCK 3, LOT 8 Location (site address) 17001 Aries Court*Anchorage 99516 Current Property owner(s) Marilyn Stovem Day phone 720-2015 Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 2 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class _Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: r Received by: I.� L� - Date: 11 kg [II COSA to be released to the engineer,unless otherwis- •. d by the engineer. COSA Fee $ 6740 Waiver Fee $ Date of Payment I ((t 11? Date of Payment Receipt Number 09ooti6 Receipt Number COSA# 4`JCI3~1519 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Gayness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101-Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: /1 J to /1 oQ00004p�4 In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system ` in accordance with the guidelines and regulations established by the Municipality of Anchorage and A t� industry practices. The reported results describe the condition of the system/s on the date/s of the ' '- ' O VOn evaluation. Separation distances were measured to readily identifiable features. Hidden defects or Ofd •- '•�QA encroachments may exist that were not identified during the evaluation. The operational life of all wells 49 \ •, tr and septic systems depend upon a variety of variables, including but not limited to, soil conditions, /-f1 f Q groundwater levels (that may fluctuate during the year), quality of construction (materials and f V ` ^ VA workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and ��/ ,/. , ,. ,O are outside the control of GEG. Satisfactory test results do not guarantee future performance of the ( •/ of�kkk///ey , rness, Q system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of V0 / CE 79x3 • a 4" the well or septic system. GEG makes no representation whether an alternative well or septic system �nn9�s 11// r c�Q can be installed on the property in the event either of the current systems fail to perform adequately in u�e .I j „6 - �Ao the future. The content of this report is for the sole benefit of the person/party that retained GEG to 44ha prp/e55i0060 perform the evaluation. Reliance upon the information provided in this report by any other person or �'DODOQoO party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #AECC884 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms vlllt4,i Disapproved ., ANC ' �� '70 Conditional approval for bedrooms, with the followin late 51:�� G'0 ,: Ora y� NIP1tER PSR 0= .-..„%,, 1 , -- kms _ •°pMENT SE0 . , By: - t` tr.,...\_ J` I ,` Original Certificate Date: i / —1J j 7 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist71 Nitrate Advisory Septic System Advisory Arsenic Advisory • Well Flow Advisory Other COSA blue sheet 10-10-12.cloc If more than 1 septic system is on the lot: COSA Checklist# of_ Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description. SUSITNA VIEW ESTATES: BLOCK 3. LOT 8 Parcel ID: 020-091-30 A. WELL DATA Well type PRIVATE If A. B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 10/21/84 Sanitary seal (YIN) YES Wres properly protected (YIN) YES Total depth 365 ft. Cased to UNK ft Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test 10/21/84 9/13/17 Static water level 35 ft. 92 2 ft. Well production 0.5 g.p.m 1.0+ g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 ml. Nitrate ND mg./L. Collected by: GEG. Ltd. Arsenic: < 5.0 ug./L. Date of sample: 10/19/17 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 10/5/84 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (YIN) N/A Date of pumping 8/17/17 Pumper NORTHLAND PUMPING C. ABSORPTION FIELD DATA 'BELOW EXISTING GRADE AT SUMP-SUMP ONLY EXTENDS 36"BELOW INVERT Date installed 10/5/84 Soil rating (g.p.d./ft'or /bdr r) 138 System type DEEP TRENCH Length 47 ft. Width 3 ft. Gravel below pipe 5.5 ft. Total depth '5 9+ ft. Eff. absorption area 517_ ft Monitoring tube YES Depression over field NO Date of adequacy test 9/15/17 Results (Pass/Fail) PASS For 2 bedrooms Fluid depth in absorption field before test 0 in. Water added 1304 gal. New depth 0 in Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 300+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes. give date - ""TWO 500 GALLON WATER HAULS WERE USED TO PERFORM THE SEPTIC ADEQUACY TEST AND 304 GALLONS OF WATER WAS USED FROM THE WELL. D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off'level at .• wa er alarm level at in. li- .-- Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field UNK Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line '0' Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 1' Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS 'SEE ATTACHED AS-BUILT SHOWING EASMENT FOR DRANFIELD(�_ COpto o 5:1T-,ec Peen '- .4-- 'T t S 4-tcorn'✓IO -, • G. ENGINEER'S CERTIFICATION 4:, ��P...•• '...... �cr1 4. /\ * 1. !certify that l have determined through field inspections and • c i. • review of Municipal records that the above systems are in • iss conformance with MOA COSA guidelines in effect on this } ?" i date. ♦�c>'• ie / . �arnsss/ L.,,,• Engineer's PrintedNa e JEFFREY A. GARNESS ••-,.2, ..• CE 79 3 , 2 Date 11 ' ' 7 /+iii'°ROFESSW44. LICENSE IIII1„IWO, #AECC884 (Rev.10/12/12) - Frontier Surveys,LLC Project No:17-211 REV.1 Date:September 29th,2017 NORTH Ordered By:Nichole Perry PIat:70-213 Grid:N/A Scale 1" I j i LOT7 11 \ J 0Ai I N _ \ SHED ta4-t J 1 �'� S' ' - I zI .nu• Susitna View Estates I ; . Lot 8, Block 3 I so ...0„i � 25,455 sq.ft. +1- 1 / ' 3 Q g 17001 Aries Court / , N I M= 3 Story Wood Framed House ^ I DIRT Ay � / ei' DRIVEWAY • I / I / c. C J I / s ' STAIRS / I I2ND STORY DECK 1111111/111/111 / ' II L t - b ' - 6.44,404 1/ ' v ,r , 4 3RD STORY DECK ' er p g - `� 22.4' nI Ill 20.6 : �"',e� ei Z 0 M `a W 1 1111114., O COVERED ENTRY i 7 if n T a o m I § / � 30'R.OW. / 1 - f I / • 1 tOQ'4�P1 4\ ..N (OVER THE PROPERTY LINE) 57��•�MF 167.22 DRIVEWAY ENCROACHMENT INTO LOT 9 LOT 9 I ' Legend: LJ Electric Meter/Outside Power rQ Telephone Pole i Gas Meter ?!i Deck -OP-Over Hanging Power 0 30 60 15 OSeptic 0 Water Well ❑ —� ' r Feet General Notes: I t ' 1.This document is created for the purpose of a single property transaction and is subject to Federal Copyright law. 1 2 .Excepting for gross negligence,the liability for this survey shall not exceed the cost of preparing this survey. "L.:: ii-D 3.All meuurements/setbacks are to the visual/apparent building footprint. v 4.Dimensions to property lines are plus/minus 0.1x. ```,SiewS\11 t E t I I conditionsThis yat the time of tplies with he survey. docortgage ument nt does ation Standards. ot constitute ayboundaryts sury Band is e improvements bject to any E F.., 4, I inaccuracies that a subsequent boundarysurveymayreveal.It is the responsibility�'( Ill q spbnsibilit of the Owner to determine �P --IS 4 !I/ the existence of any easements,covenants,or restrictions which do not appear on the record plat.Under no C., _ !/ circumstances should this document be used for construction or for establishing a boundary or fence line. *..• 49TH i` '.* , As-Built Survey of: --7.......‘2_•- ......--•-•' ......‘2_ Lot 8 Block 3, Susitna View Estates .7, FREDERICK w.61464ER .n¢ I,Frederic Wagner,hereby certify that this Mortgage Inspection Survey was performed by me,or i/reF,,, ', NO.1_5.-111146 i under my direct supervision on September 24th,2017. r2 A '. 10/2/2017 .' _ . ,e,„ • lflf� . •' �` Frontier Surveys,LLC FRO Tj'IER. I t "re I SSIONA 650 W.58th Ave.Suite E Anchorage,Alaska 99518 t ~` t E tlt.t� �� � •� 907.460.1686-info@frontiersurveys.com i.S PROFESSIONAL SEAL www.frontiersurveys.com • Frontier Surveys, LLC Project No: 17-318 Date: October 12th, 2017 NORTH Ordered By: Beth Simpson PIat:70-213 Grid:N/A Scale 1"= ' 10' I F, 4 4 w • 1 I- • 7 o ., $ 8 0..01) N g0 f N i F___ Q0 N g7 O is DIRT DRIVEWAY M H ` c LOT 8 ( ) BLOCK 3 STAIRS 2ND STORY DECK 1111//11/8/11' $ co I �,•, o° i0� ,s#44j ENCROACHMENT EASEMENT AGREEMENT THIS ENCROACHMENT AGREEMENT made and executed this 11t21 2017, by and between BILLY RAY POWERS, who also appears of recor�9 as BILLY POWERS, a(n) S N1 qk P. person, whose address is 18291 All Elks Road, Chickaloon AK 99674-7902, ifereinafter referred to as "Powers," and MARILYN J. SCARBOROUGH, a(n) Mr e,r r led person, whose address is 927 Crown Court, Fruita CO 81521, hereinafter referred to as "Scarborough." This Encroachment Easement shall become effective on the date it is recorded, shall run with the land and shall inure to and be for the benefit of all owners and future owners of the subject real properties. WITNESSETH WHEREAS, Powers is the owner of the following described property: Lot 9, Block 3, SUSITNA VIEW ESTATES, according to the official plat thereof, filed under Plat Number 70-287, Records of the Anchorage Recording District, Third Judicial District, State of Alaska. hereinafter referred to as"Lot 9"; and WHEREAS, Scarborough is the owner of the following described property: Lot Eight(8), Block Three(3), SUSITNA VIEW ESTATES, according to the official plat thereof, filed under Plat Number 70-287, records of the Anchorage Recording District, Third Judicial District,State of Alaska. hereinafter referred to as"Lot 8." NOW, THEREFORE, for and in consideration of the covenants and conditions set forth herein, the parties do hereby declare as follows: The parties hereto agree that the driveway presently serving the residence located on Lot 8 encroaches onto the property of Lot 9 and a driveway easement for the benefit of Lot 9 will encroach onto the property of Lot 8. Powers as the Owner of Lot 9 and Scarborough as the Owner of Lot 8 grant encroachment easements for said driveways as set forth on the attached Exhibit and designated as "A." Perpetual Encroachment Easement,Page I of 3 These documents have been prepared pursuant to a Document Request. You are encouraged to seek independent legal advice regarding your objectives. The parties hereto agree that a portion of the septic system servicing Lot 8 encroaches onto Lot 9 and Powers as the Owner of Lot 9 and Scarborough as the Owner of Lot 8 grant an encroachment easement as set forth on the attached Exhibit and designated as "B." Said easement is for the purpose of the existing septic system servicing Lot 8 and a portion of the driveway access for Lot 9. Should the septic system fail and/or be replaced for any reason, the parties agree that the new septic system servicing Lot 8 shall be placed entirely on Lot 8. This encroachment easement shall run with the properties described herein and shall be a benefit to and binding upon the undersigned and any person who shall hereafter acquire title to said properties. 111 DATED this /�j day ofLE,itAE� , 2017. r -„J BILLY RAY OWERS STATE OF ALASKA ) )ss: THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this )3 day of () A.p�Y' -k4:,f ,2017, by BILLY RAY POWERS. %c.;‘,1a.PEA,,,,,:lre �` 1.err • o'rARY Notary Pu• tc in and or Alas i� My Commission expires: ' I'. 46:•. . : �i OF�"0 Perpetual Encroachment Easement,Page 2 of 3 These documents have been prepared pursuant to a Document Request. You are encouraged to seek independent legal advice regarding your objectives. DATED this_ day of__1.70Lrerp b r,- ,2017. • • I YN J C• r.-OROUGH STATE OF COLORADO ) )ss: COUNTY OF f/><.,GScti, . ) The foregoing instrument was acknowledged before me this '2 day of ptr ervti b r ,2017,by MARILYN J.SCARBOROUGH. Nota ' i.lic in o orado I MICHELLE DIDONATO My ••nimission expires: '-7 Jam/ao"q 4 Nota ryPub lic State of Colorado Notary ID 20104026883 1 My Commission Expires Jul 27, 2018 Please record in Anchorage Recording District and return to Marilyn J. Scarborough 927 Crown Court Fruita CO 81521 Perpetual Encroachment Easement,Page 3 of 3 These documents luny been prepared pursuant to a Document Request You are encouraged to seek independent legal advice regarding your objectives. Frontier Surveys,LLC Project No:17-318 Date:November 13th,2017 NCORTN Ordered By: scale 1-•30' Billy Ray Powers PIat:70-213 Grid:N/A It 75 0 qq 5. .. • O rY OA I DIRT DRNEWAr i y o I LOTS I BLOCK 3 t ISTAIRS t LSD STORY DECO fflff/fffffffff I to I.. ,�. : ' 4 CK O , 14 ♦ , 3RD STOay DECK. p " H P Vt 44 ,♦ft4.6, Easement Detail Q ;; N.-51',1"W Lots 8 & 91 Block 3 Q l�"., ••'20'99rW 0.00 `r Susitna View Estates NW 00'49-W 15.64 N�'17'02'W SHED C2 509'D3'21'W 12.10 / N79.17' j I I IO? art N1l'59'an 9.23 s MIL .37 EASEMENT ATOTAL AREA•33SLa.fl.4/. Z 500'03'21'3 15.31 - m N11'S9'10"E 10.00 ' B N11'59'11'E 10.00 I SEPTIC Tuff A~ I \N"'S9.30'W 43.37 Nil 59'11'E 10.00 SA'0049•f 776.66 I S78'00'411 8.47 0 47 23`W 4.00 I N89`56'39'W\5.00 IEASEMENT S tOtat AREA•6E4 s4,h../. I ` _ OSE I/ PROPOSED DRIVEWAY TO LOT y` I \ LOT 9 BLOCK 3 ' I t t 4 Legend: a Electric Meter/Outside Power Telephone Pale , - ® Gas Meter $ Deck —We—Over Hanging Power 0 c 30 80 SSeptic e Water Well ....r.. Feat General Notes: 1.This document a created for the purpose of a single property transaction and rs subject to Federal Copyright Law. 2.Excepting for gross negligence,the liability for this survey shall not exceed the cost plundering this survey. 3.AN measurements/setbacks am to the visual/apparent budding footpnnt. 4.Dimensions to property lines we phis/minus 0.1h. ''•,ti,,+v\\\S\1 t t 11 This survey complies with AWLS Mortgage Location Standards.The survey represents visible improvements and C1 F ! 1,I! conditions at the time of the survey.Thrs document does Oct constitute a boundary sunny and is subject to any '( '9 'Q r! inaccuracies that a subsequent boundary survey may revel.It Is the rasponsibltity of the Owner to determine ----4P..• s• 4 !i the existence of any easements,covenants,or restrictions which do not appear on the record pint.Under no 9, ,• 4 fj circamstarscas should this document be used for construction or for establishing a boundary or fence line. *.-' 491"''.4' %.* i' Def Easement fon �'''��,��}J i Lots 8&9, Block 3, Susitna View Estates i�` reaoaRrca W.eYaFwR I,Frederic Wagner,hereby certify that this plat represents a survey performed by me,or iii C 1/'ts.ia4ty under my direct supervision on October 12th,2017. rr 4:le' 11/13/2017 •' yf f�,t�,� r Frontier Surveys,LLC FRONTIER f b 11 t orE, sSlONpL``..- 650 W.58th Ave.Suite E Anchorage,Alaska 99518 e (tt\\\\\•••" 907.460,1686-info@lrontiersurveys.com S PROFESSIONAL SEAL. www.frontlersurveys.com EXHIBIT A