Loading...
HomeMy WebLinkAboutSWANEE SLOPES #1 BLK 1 LT 4zz/ 05! GREA ,-/'-R ANCHORAGE AREA BOR ,JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: INSIDE LENGTH INSIDE WIDTH MATERIAL NUMBER OF COMPARTMENTS LIQUID DEPTH LIQUID CAPACITY__ GALLONS. TI'~ N F,F,-D: DISTANCE FROM WELL/~'';~' FOUNDATION 3Is-! NUMBER OF LINES / DISTANCE BETWEEN LINES ABSORPT,ON DEPTH: TOP OF TILE TO FINISH GRADE TOTAL LENGTH NEAREST LOT LINE ~-f~'~J~ _OF LINES TRENCH WIDTH ~:~'IN. TOTAL EFFECTIVE SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER ~__¢ IN, C~ MATERIAL BENEATH TILE IN. ABOVE TILE WELL: TYPE-~}~'~'~' t CONSTRUCTION BUILDING ~ NEAREST NEAREST FOUNDATION__ LOT LINE SEWER LINE DEPTH SEPTIC SEEPAGE TANK SYSTEM CESSPOOl OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: INSTALLED BY: SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: /¢ 6/'g~ / ' REMARKS: // DIAGRAM OF SYSTEM i/ D AT E/"/'/'~'/- '~' A P P R O V'~"h'3 ~x"¢?'"~ "~ ~-~'''~'U Gg.A.A.B. ......... ~... 'i~'UNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99502 276-222~ SOILS LOG -- PERCOLATION TEST '~ I~r SOILS LOG [] PERCOLATION TEST LEGAL DESCRIPTION: ~ ,4- /:.31~::~k-- 2 3 .,----4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 20- SLOPE /ova --- ~aydq 3,e_~aa/ L~W) Well q/~aded/ Id-Me 4o ,~o WAS GROUND WATER ENCOUNTERED;) DATE PERFORMED: IF YES, AT WHAT DEPTH;) SITE PLAN _ I o ~ p 4. Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND -- FT PERFORMED BY: '/~//3W~/-~"~ 72-008 (7/76) CERTIFI ED BY: fl///]~-~//¥ -- ~'~'~? cg' ~ DATE: GrEaTer ANCHOrAgE ArEA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-456 ! SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO. 76 ~'~ ~ , OTHER NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL ]BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE MINIMUM DISTANCES, RE<:/UIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK -, SEEPAGE P}T . TO NEAREST LOT LINE. WELL TO SEPTIC TANK WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPT,C TANK. , SEEPAGE P'T CAST IRON INTO AND OUT OF SEP TANK AND INTO CRIB CI GAP OF EXCAVATION 5 FEET INTO UNDISTURBED IL. 4 INCH DIAMETER CAST IRON SI ANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. ~ TYPE DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE ~I~UNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99E02 276-2221 SOILS LOG - PERCOLATION TEST ~ SOILS LOG [] PERCOLATION TEST PERFORMED FOR: ~.~.U~~') ~.~'~'~.C/C~-I~"~? DATE PERFORMED: LEGAL DESCRIPTION: 1 2 3 4 5 6 7' 8 9 '10 - 11- 12- 13- 14- 15- 17- 18- 19~ 20- SLOPE SITE PLAN~ WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop COMMENTS /~,-~f/~m~nd t,(,~e PERFORMED BY: ['~t l /Zl CZC[ ,~', t/~C2~,~L.ff 72-008 (7/76) PERCOLATION RATE minutes/inch TEST RUN BETWEEN FT AND , FT GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received September 29, 1976 t'~ ~ ~ Time of Inspection ~/~/~ ~/ ~ ~ Date of Inspection / ' [ I~ ~I~UAL SEWER & WATER FACILITIES ~ ~ ~ ~ U FOR gpproval 11:30 a.m. 10-1-76 Friday Neale requested by: State of Alaska, Veteran's Administration Mailing Address: Phone: 2. Property Owner: Philip D. Ault Phone: 279-6622 Mailing Address: Box 175 Chugiak 99567 3. Legal Description: Lot 4 Block 1 Swanee Slopes 4. Location: Mile 19½ Old Glenn Highway 5. Type of facility to be inspected Single Family Community B. Depth Well Data: A. Type C. Construction Sewage Disposal A. Installed C. D. System: 1965 Septic Tank: 1. Size Seepage Pit: 1. Absorption Area E. Disposal Field: Total length of lines Distances: A. Well to: Septic tank Nearest lot line B. Foundation to septic tank No. of bedrooms 2 D. Bacterial Analysis On-site system, B. Installer 2. Manufacturer 2. Material ., Absorption area , Other contamination , Absorption area C. Absorption area to nearest lot line , Sewer Lines EQ-034 (1/74) Page 1 of two pages Page 2 of t~o pages - Re(~.xst for Approval of Individual ~.~ar & Water Facilities 'Legal DescriDti0n Lot 4 Block t Swanee Slopes Comments Approved ~-~ ~~ Di sa pproved ~/~ ~alid for one year from date signed ~/Gr~ter Anchorage Area Borough, Deoartment of Environmental DIAGRAM OF SYSTEM Quality c'ertify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) MUNICIPALITY OF ANCHORAGE ' DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: 2. Property Owner: Mailing Address: 3. Name of Buyer: Mailing Address: /~ ~ ~/~ 4. Name of Lending Institution: FHA _CONV Day Phone: Day Phone: 27 ~?~ -. $'~g ~? Mailing Address: Phone: 5. Name of Realtor or Agent: Mailing Address: ~/~ ~, ~.e-.~ Phone: ~q~-~ Location: 7. Type of Facility to be Inspected: 8. Water Supply Type of Supply: Public Utility No. Bdrms. Individual If Individual, number of dwellings presently served If Individual, depth of well Sewage Disposal System Type of System: Public Utility If Individual, date of installation ' /q fi, -~'-~ Individual (on-site) 72-003(3/76)