Loading...
HomeMy WebLinkAboutOLSON HEIGHTS BLK 2 LT 6Onsite File S.a MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191135 Effective Date Work Type: SepticTank Upgrade Tax Code Number: 01823112000 Site Legal Address: OLSON HEIGHTS BLK 2 LT 6 G:2936 Site Mailing Address: 4450 E 135TH AVE, Anchorage Owner: Jahnsen Petter Design Engineer: C & M Engineering This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Expiration Date: Lot Size in Sq Ft Total Bedrooms: lll�Ilr ~ sr v; i_)elattl'Ct71C'IlC 4/26/2019 4/25/2020 49500 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: Issued By: �Date: Y/2 to /f' 3 Em P1 ANS RUSH MUNICIPALITY,OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section -' Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 018 -231X -ID, a Property owner(s) Petter Jahnsen Mailing address Site address 4450 E 135th Ave Day phone Legal description (Sub'd., Block & Lot) Olson Heights Block 2 Lot 6 Legal description (Township, Range & Section) Lot Size 49,500 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) 0 Septic Tank 0 Upgrade 0 (w/wo AD U) Holding Tank ElRenewal ❑ Duplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. C&M ENGINEERING (Signature of property owner or authorized agent) Permit/Rush Fees: 310o Waiver Fees: Date of Payment: _ Wa 5 !l 9 Date of Payment: Receipt Number: (1)L/ Receipt Number: Permit No. 05P19 Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water & Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 04/25/2019 RE: Proposed Septic System Modification for Olson Heights Block 2 Lot 6 Dear Reviewer, The above referenced property is currently served by an older 4 bedroom septic system. The 1000 gallon tank has failed and is in need of immediate replacement. We are proposing that the existing tank be replaced with a new 1000 gallon (minimum) tank constructed and installed in accordance with MOA requirements. A polyethylene or advanced coated tank is recommended. As shown on the plan, the tank will be greater than 10’ from the house foundation. The tank shall be covered with a minimum of 2” moa approved insulation and 3’ of cover. The repair shall be performed by a moa certified installer in accordance with MOA requirements. The engineer will inspect the tank before backfilling. Repair of the proposed system will not negatively impact adjacent lots. Upon completion of the installation, a record drawing will be submitted showing the location of the new tank, leachfield, well, and other applicable features. Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854- 5558 or by email cgbalzarini@gmail.com with any questions or concerns. Sincerely, Charles Balzarini, PE (04/25/19) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191135, Rebecca Carroll, 04/26/19 �1� Qe�' tewater LEGECLEANOUT & D A . ANC • MONITOR TUBE C�SP191135, Re • C2r�b11 1 BLOCK 1 TEST HOLE LOT 6 / *� lli •* r/ (WELL MORE THAN 200'•• •••• ••• 0.5%\ SLOPE INDICATOR FROM PROPOSED UPGRADE) t ow .. • . • • • • • . CHARLESG BALZARIM ••`` j•.• CE -13854 •. ��� c E 135TH / I EXISTING DRAINFIELD TO REMAIN LOT 5 LOT 6 LOT 7 I Y14' EW AFTER NK COs /EPLACE EXIST TANK WITH NEW 1000 AL TANK. DEMOLISH LD TANK PER MOA EQUIREMENTS EXIST FOUNDATION CLEANOUT. REMOVE DEBRIS AND INSPECT PIPEFORDAMAGE 100' WELL RADIII \ 3 BR HOME THE PROPOSED SEPTIC TANK IS GREATER THAN: 100' FROM ANY PRIVATE WELLS 200' FROM ANY PUBLIC WELLS 100' FROM ANY SURFACE WATER 10' TO ANY PROPERTY LINE OR FOUNDATION / SCALE: 1" =_3Q' LEGAL DESCRIPTION: OLSON HEIGHTS BLOCK 2 LOT 6 C&M ENGINEERING SERVICES OWNER: JAHNSEN DATE: 4/25/19 1 REV: I DR 907-854-5558 SITE PLAN MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH 86 ENVIIRONMENTAL PROTECTION ENVfRONMENI'AL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEI~4 AND/OR WE!..L INSPECTION REPORT I Liq. e~p~.city ~/ gallons ' Q Well '-- . ~"D~ c ,STA~-~O: Well ~ lCl~s Depth Inside length Dwel n9 Dwelling Width NO.O~,~EDROOMS I PERI~tJ~T NO, ~ Liquid depth Foundation ~ ,/ ~_Neares, lot tine~;;~.,~l ~' PERMIT Total length of Ib]e,---/~~:------ Distance~.)tl~y~.~ :ina, Ma t ~ i~ne n~e~ ti. o L_ ,~- * inch eL ~_otel e f fac t~l~..~ti on a rea Depth PERMIT NO. I ~apacity . Matorial in gallons PERMIT NO. Crib depth Total effective absorption area Building foundation Nearest lot line Driller Distance to lot line PERMIT NO. Sewel line Septic tank Absorption area(s) OTHER -PIPE MATERIALS _ .... -REMARKS DATE LEGAL C~ 0 0 0 0 0 0 0 0 0 0 F':'EFiJ"I I T NO. FtF'F'L I CI:::II",I'T' L,OCFI'T 101",1 MEGFIL. I>EPF!F;YFHEiI,I'I" 0'":' t'IEI::ILTH f:tl",lD E';NVII:ROt"-IMEi",rI"F:IL. ~'"'='O'T'E'C'I'IOI',t 825 ( 8q. 0_!:72 > f,l[Ng% E E:EETER HI...IF F H F:Ii'.,I F:IREFI L..'T'6 E:L,~< LT..' OLSEiq Ir'Vr:i~; S '1" Fi'. E IE "1"., FI ~.,J (2 H 0 F~:'. FI G E., FII<. 9:5 i 2 6 4 - 4 7 2 0 CJ ~'..,,11 ...... "_"-".~; I; '"F E; SF; E t.,,.~l IE{ F: SRFI E:::-:,' :1..546-E L 0 T S I Z E 'T'T'F'[i: OF' SOIL. I=IBSORPTION ."3'¢S'FE:H IS: TRENE:H I"tF:i::-,:ll'lLIhl 1'.41...Ii'"I[!!~[EI',:: OF BEDROOHS ::= SO i L RFI'I" I t',IG ( S~;:! FT,..'BF4: ::, = 8 5 TFIE REQI...I I REI:, S i ZE OF THE Slil;[ L. FISSORPT I 01'.,I S'¢S]"EI"I 1:5: THE LENGTF! DIHEi'.,ISIOI'.,I IS THE L. ENGTH ,:lIN FEET> OF' THE TREI',ICH O1:~'. I)F::FIINF'IEI.~.[:,. THE [)EPTH OF FI TREI'.4C:H OR F'IT IS THE.'". DIL:,TRNCE BE:TI.,.IEEt',I THE SURFFICE OF' ]"FIE GF::OIJI'.4[.', FiI',t[:, TFIE [.:.",OTTOH OF THE EHCFIk,'I=ITZON < IN FEE]'). ]q-'IEP;!E I:5 NO SET I.,.IZ[:,TH FOR TRENCHES. 'T'H[:=' GF4:R'v'EL. DEPTH IS THE I',lllqlr,ll...IH [:,EF'TH OF GRFI'v'E:L E',ETP.I[.iEN THE OtJTFRLL I:::'IF'Ei FII',I[:, THE BO'[']"Ot',I OF' THE EHCI:I'v'FtT I ON ,:: I N FEET ::,. [::'E:f~".H I 'T' FIF'PL. I CFII'.,IT Hl:::r3; THE RESt:)ON:.E; I E: I I... ]: 'l""r' "['O I HF'ORH "I"1.-I I S [:'EPRF:t'I'HENT ['.,L.II;i: I 1"4G 'THE I I'.,I'.:];"FIZlLLtYT I O1'.,I ~ N~;F'IEE:"I" '[ Ot'.,I'S OF: F:li",l"r' HEELS FID,J'F!C:EI',tT 'T'O TI4 Z ~ F'f~]OPEF,;:T'¢ FIND 'T'H[C t"4L.If'IEi:EF'. OF RE=";IDENCES q"FIFCI" 1"HE HEL. L HILL SER',,,'E. ............... 'IF ~..,.I1 {l~ ,:: 2 X::, % IN,It .".:.':.:..; F' EE C: 'T L[ C~ !',.!~ ..%.a; [:::;:11 IF;i;: E; F;?. IL:.E F=:L, L.II 31:: .'F~:'. El E3: ..................... E',I=IE:KF Z LL I I',IG OF:' Fl1'4'¢ S'¢L=;TEH t.,.I I THOUT F I I'.,tRL I NSF'ECT 101'-,t I=11'.,1[:, FIF'F'ROVFII... B'¢ 'TH I :i.:.; [:,EPFIRTMEI',IT I.,.IIL. I... BE SUBJECT "1"O PROSECUTION. MtNIHLli"I DiSTFII',ICE E:ETHEEN Ft HELL. FIND I::II",IY' ON-.-SITE S[{NI::IGE DISF'O'_:::;FIL ::i:;"r'9;'I"E:H I'i; :1.00 FEET FOF..' R F'F..'I'v'FtTE HELL. OF.': :L50 TO 298 FEET F'ROH F:I F:'UBt_.IC HELl.. LIF'OIq ]"FIE' T'¢PE OF PUBLIC 14ELI .... h'I].'I",IIHUH [:'ISTFINCE FREe1 F:i F"F.:I'v'FITE t.4ELL TO FI PR.f. VFITE :~;[Et,.IEF~'. LINE ];:;5 25 FEET TO !:=1 COHHUf'ilT"r' SEI.,.IER I....INE IS 75 FEET. I.,.IEL. L. LOGS Fff;.'~E F'.':Eg!IJIRIEI3' RN[:' I"ILIST BF RETUI;;:t,tED TO THE [:'EF'RRTHENT I.,.IZTI"I:I:f",I 30 I:::'FI"r'S OF THE 14EL. L COI"IPLE:T 101",I. O]q"'lEI;i: t;i'.E6!U :1; REP1EI'4T'::; MFI"r' FIF'PL'¢. SF'EC Z FI CFIT IONS FIN[:' COI",!STRUC]"~ LqN [:, Z RGRRHS RRE FIVFI I L. FIEd_E TO I t',I::!;URE: PFi:Of::'ER t i",IS TRLLFIT ]: ON. I CEF:T I F"r' TFIFI]' i: I Rf'l FRI"IIL. IFIR HITH THE F::E:g!I.JIREHENTS FOR OI",t-'SITE !:=,EHERS FIND I.,.IELJ....S l::l'ii; FOR'T'H B'¢ THE I'"IIJN I C I F'FIL I TY' OF RI",ICHORRCiE. 2: I I.,.IIL. L It',IL=.,'I"I::ILL. THE Sh"STEP! I1",1 F~CCORDRNCE t.4ITH TFIE C:O[:'E:5. 3: I LIIqDEF::STFtND 'T'HFIT THE ON-SITE :E;EI.,.IEI';.r S"r'STEH r,lFl't' RE(;!IJIRE EI'.,tLRF.:GEFIENT iF THE RES 113,EIqC:E I S F.:~Ii1E~E:,ELIED TO :1: I',ICLUDE t"IORE THRI',I 3: DE[:,RE,3PI!iF,. /.. SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L Street, A~charage, Alask,~ 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1) 20 Z.c~T ~ SLOPE ~- _S' w.$ o,~OUN,:, WATER ENOOUNTE,EO' P E IF YES, AT WHAT DEPTH? DATE PERFORMED:, SITE PLAN I I I - Re..~l~.~'! "%~'D~ .f~ Gross Net Depth to Net .~:~, ~'tI: ,~,! ~h, Time Time Water Drop ~ ". C' -4d[;3 ."' ',' "~ PERCOLATION RATE TEST RUN BETWEEN ~ FT AND / L¢':~ FT ~2-008 (6/79) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 1. GENERAL INFORMATION Complete legal description Blk 2, Location (site address or directions) 4450 E. 135th Ave., Anchor:age Propert¢ Owner ~so. Mere Mailing address Day phone Agent ]~. l[oou,c Day phone 276-2001 Address 2600 Denali St. ~Ste 400, /~cho~a~;e, AK 99503-2740 Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF FIEDROOMS: 3 ~ 3. TYPE OF WATER SUPPLY: Individual well X Community well Public water NOTE:, If community well system, provide written confirmation from State ADEC attest- lng to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site X Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 Lending agency Mailing address 4450 E. 135th Ave., Anchorage National Bar~k of Alaska Day phone Ho~tgage Loan Dept.., 1500 W. Bensot~ Blvd.~ 4th Attention: Shi~'lin Wells ')pOM s2eau!Sue leUO!SSejo,id eql u! suo!ss!tuo Jo sJoJJ8 Jo~ elq!suodseJ lou s! @SeJoqou¥ jo /q!led!o!un~ eq/ 'penss! s! el~o!J!lJeo e @Jojeq elep eZXleUe Jo suop, o@dsu! lonpuoo ~ou op SHHQ ,to sea,~OldLU~t 'sluewej!nbe~ e~m,s pue le~epet u!elJeo ,9,s!~es ol Jep~o u! suo!lnlp, su! 8u!pu@l J !eql pue sewoq jo sJeseqoJnd o~/~selJ noo e se 9!ql seop SHHQ eqJ. 'e~Sel¥ Jo e~19 eq~ u! p@JelsilSej Jeeu!Sue leuo!ssejmd ~uepuedepu! ue ,~q e^oqe g qdeJS~Jed u! ua^!8 suo!lelueseJde~ eq; uodn /~lUO paseq seleoWlJeO le^oJdd¥ /qpoq~n¥ qlleeH senss! (SHHQ) seOIAJeS UeLUnH pue q~leaH Jo luetuluedecl eSeJotlouv JO/q!led!o!unlAI eq.!_ SlUeLULUOO leUO!l!PPV :suop, elndp, s 13U!MOiiO,t OH; qj!M 'stuooJpoq 'swooJpoq Jo,t le^oJdde leUO!1.!puoo 'poAoJddes!C] Jot peAoJddv '-~ =IarlI~NDIS SHHO "9 9Ig66 )IV Ogg~-g9g euoqd '°~e-aoqou-v 'IE p-'lTnS ''p}],~UTT~OC[ '~ 106 ssoJppv 'Dill[ 'quol,io~euPd~ T,e_3t~et,uO2TAU~ WJ!_-I,tO OWeN 'uo!loedsu! S!Lll ,to elep eq; uo loeJ-Je u! suo!lelnDeJ pue 'seoueujpJo 'sepoo e~elS pue led!ojunR lie qli~ @oUe!ldwoo u! s! LUm, SXS lesodsip JoleMa~se~ ~o/pue/,Iddns ]ole~ e~!s-uo eq~ 'uo!loadsu! pue uop, el3p, se^u! aw Luo~,t pue Sal!,t oBe~oqouv ,to/qlledp!unlAI eq~ LUO4 pau!e~qo UOp, eLU~O,tU! aq~, uo peseq ~eq~,~,tpe^ ~equnj I 'u!e~eq poleo!pu! eJnlomls Jo ed,9, pue swompeq ,to Jeqwnu eql ~o~ elenbepe pue leUO!~oun,t 'e,tes s! welsXs lesodsip Jele~elSeM ~o/pue ,~lddns JaleM o~is-uo eq~ ~eq~ s~oqs uo!leOildde le^o~ddv X~poqlnv q~leeH s!q~ ,to uop, eGi~se^uj /~w leql X,t!Jo^ I 'MOleq UMOqS elep uop, ep!le^ eql Jo se pue ole~eq poxwe lees ALU Xq powlJeo sV Id:I:INIDN:I Alt NOIJ. O=IdSNI .-I0 .LN=IIN=I/V.I.S '~ Municipality of Anchorage Department of Health and Human Services HEALTH ,AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 6, Blk 2, Olson Height Parcel I.D. A. Well Data Well type PrivaLe If A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) Y Date completed 6/2.8/81 Driller S),'ren Bros. Drill~_ng Inc. 1 f~. 5 Jrt. abovxLG.L. Total depth ¢_5Z ft. Cased to drlkaown Casing height Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y FROM WELL LOG AT INSPECTION Date of test 6/28/81 -- Static water level 118 ft. 115 f.t Well flow 8 g.p.m. Pump level 1 Unkno~ca Unk~ SEPARATION DISTANCES FROM WELL TO: O7- ~ rz Septic/holding tank on lot 135 ft. Absorption field on lot _ 141 ft. Public sewer main N/A Sewer service line N/A ;On adjacent lots 100+ ft. ; On adjacent lots __ i00+ ft. Public sewer manhole/cleanout N/A Petroleum tank N/A WATER SAMPLE RESULTS: Coliform 0 colifom/lO0 Date of sample: 9-i-93 Nitrate 1.31 rog/J_ Other bacteria Collected by: D. Neo);J FIoBe B. SEPTIC/HOLDING TANK DATA Date installed 5/30/8/_ Cleanouts (Y/N) Y High water alarm (Y/N) N Date of pumping 9-2-92 Tank size fO00 8a Foundation cleanout (Y/N) Compartments 2 Y Depression (Y/N) N Alarm tested (Y/N) N Pumper isaacs Pm~pin8 Service SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot 135 fi:. To property line 50 ft. Surface water/drainage On adjacent lots i00+ ft. Absorption field 31 It:. i00+ fL, Foundation i4 ft. Water main/service line N/A 72-028 (~93)' Front CONTINUED ON BACK PAGE C. LIFT STATION ~T/A Date instal[ed Size in gallons Vent (Y/N) High water alarm level "Pump on" level at Manufacturer Manhole/Access (Y/N) "Pump off" Level at Cycles tested Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots Surface water D. ABSORPTION FIELD DATA Date installed 5/~0/~1 Length ~J- ~:'~. Total absorption area Date of adequacy test W1/93 Water level in absorption field before test Peroxide treatment (past 12 months) (Y/N) Soil rating (GPD/Ft Width 3 L--. t, Gravel thickness 340 .sq L't_. Cleanout present (Y/N) ¥ Results (pass/fail) t'a~ System type r±l:e~)ch 4 ±'~. Total depth ~.'~ Depression over field (Y/N) for ~ Bedrooms Aftertest 7 :[:'L. 2 i~ ~-c:;~,~ If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot 135 To building foundation On adjacent lots 100+ £L. Surface water 100+ Curtain drain On adjacent lots LO0+ ±'L. Property line 25 fi:. To existing or abandoned system on lot Cutbank [q/A Water main/service line Driveway, parking/vehicle storage area 34 E. ENGINEER'S CERTIFICATION I certify that I have checked, verified, or,conformed Signature Engineer's Name ¢-~/(,,~ , , Date ': ~o ali MOA and HAA guidelines , of this inspection. HAA Fee $ ~.~ 0~) Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number