July 8, 1999
Jeffrey & Tammy Brown
17_108 Laona Drive
Ea~le River, AK 99577-8507
Subject:
Overlook Estates #1 Lot 2
Permit # SW970403 PID # 06804127
The subject permit, issued 11/24/97 by this office for a single family well and/or on-site
wastewater system, has expired as of 11/24/98.
If you have drilled the well, a well log must be sent to this office for documentation of the
installation and to close the permit.
If a licensed Professional Engineer has inspected the installation of the on-site wastewater
system, the original as-built inspection report must be sent to this office for review,
approval and documentation. All inspection reports must be submitted within 30 days of
construction completion.
A new permit must be obtained from this office for a well and/or on-site wastewater
system NOT installed by the expiration date.
When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit
and $120.00 for a well permit.
If you have any questions, please call this office at 343-4744.
Jan/esS~ Cross, PE
Program Manager
On-site Services
enc: Copy of Permit
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW970403
DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES
OWNER NAME:TIPPAH TRUST
OWNER ADDRESS:4155 TUDOR CENTRE DRIVE
ANCHORAGE, ALASKA 99508
DATE ISSUED:il/24/97
EXPIRATION DATE:Il/24/98
PARCEL ID:06804127
LEGAL DESCRIPTION:
OVERLOOK ESTATES #1 LT
LOT SIZE: 329167 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: ~
DATE:
DATE:
Eagle River Engineering Services
Louis Butera, P.E.
P.O. Box 773294 (907) 694-5195 tel
Eagle River, AK 99577-3294 (907) 694-3297 fax
November 7, 1997
Jim Cross, P.E.
Manager, On-Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Overlook Est. #1 Lot 2
Narrative & Permit Application
Dear Mr. Cross:
The proposed well and septic system will have very limited impact on adjacent properties for the
following reasons:
1. The surrounding lots are large, allowing sufficient room for septic sites.
2. Immediate neighboring septic systems are all +30' distance.
3. Reserve space is adequate, due to absorption capacity.
4. Drainage will not be affected and is not a major consideration in our design.
If you have any questions please call our office at 694-5195.
Sincerely,
Louis Butera, P.E.
RECEIVED
\ 1997\97-082-NAR.DOC
NO SURFACE WATER EASEMENT
NO KNOWN CURTAIN DRAINS PROPOSED
NO DEVELOPMENT ON SURROUNDINO LOTS, +200' i- EXISTING LEACHFIELD
W E L L/' S E P T I C S I T E P LA N
LEGAL: OVERLOOK EST. ADEN ~1 LOT 2
OWNER: Alosko Development Corp.
CONTRACTOR:
JOB~
(907) 694-5195 FAX: (907) 694-3297
Eagle River Engineering Services
Louis Butera, P.E.
P.O. Box 773294 (907) 694-5195 tel
Eagle River, AK 99577-3294 (907) 694-3297 fax
LEGAL:
A.
1.
2.
3.
SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM
Overlook Est. #1 Lot 2
11/7/97
.GENERAL
The well and septic plan are for a single family residence only.
The drawing and or site plan shall be a part of this specification.
All materials and workmanship shall meet the Anchorage Department of Health and State
Department of Environmental Conservation requirements.
4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer.
5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet
Municipality of Anchorage, Department of Environmental Conservation requirements.
6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any
adjacent multi-family wells.
7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer
approval.
8. It is always recommended that a surveyor locate the nearest lot line position and the location of any
easements.
9. Any remaining open test hole excavations shall be filled.
B. SEPTIC TANK
1. The septic tank shall have a minimum capacity of 1250 gallons and be of MOA approved design.
C. TRENCH
1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom.
2. The bottom of the trench shall be level, plus or minus 1.5".
3. The total depth of the trench excavation is not to exceed 6' at any point.
4. The effluent line within the trench shall be laid level within 0.03'.
5. The trench gravel is to be covered with typar fabric material.
6. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed
over the leachfield,
7. The area over the trench is to be finish graded to prevent ponding of surface water runoff.
8. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any
Class "C" well, or 200 feet to any community well.
RECOMMENDED LEACHFIELD DIMENSIONS:
TOTAL DEPTH = 6' GRAVEL DEPTH = 4' under pipe, 2" over pipe
TRENCH LENGTH = 75' TRENCH WIDTH = 5'
SOIL RATING = 0.8 GPD/ft5 BEDROOM CAPACITY = 4
SEPTIC TANK = 1250
Twenty-four (24) hours notice required for all inspections.
\1997\97-082-spc.doc
EAGLE RIVER
ENGINEERING SERVICES
P.O. Box 773294
Eagle River, Alaska 99577
(907) 694-5195
ERES Project No.: 97-082
Calculated By: LB
Date: 11/7/97
Legal: Overlook Est. #1 lot 2
Single Family 4 Bedroom Dwelling
TEST HOLE
Shallow Trench Subsurface Wastewater Disposal Field
Water use at 150 gallons per bedroom = 600 gallons
Percolation rate = 6.7 minutes per inch
Wastewater application rate = 0.8 gallons per day per square foot
Required absorption area = 750 square feet
Trench width (W) = 5 feet
Gravel depth (D) = 4 feet
Required length = Shallow trench factor* Required absorption area / W
Shallow trench factor = (W + 2) / (W + 1 +2 D)
Shallow trench factor = 0.50
Total Excavation Depth = 6.0 feet
Required length = 75 feet
Munlcl
DEPARTMENT C
825 "L'~ Street
SOILS LOG
LEGAL. DESCRIPTION: ~/.~f)-~'~' I 4~//~f't'~#/'~''
+
7
8
9
10-
13.
17-
18-
ACCORbANCE WITH AL L STA~E AND MUNIBIPAL
OF H~LT. & HUMAN'SERVICES
L A~chorage, Alaska 99502~50
] ~ PERCOLATION TEST
~"~, ' DA~E
~.:~/Township, Range, Section: . ~7~ff ' ~J~
, , ~
I.
EN~OUNTERED~ .
L
~eMh · W~ After .
: Gro;~ - Net 'D~th to
Re.lng Date Time Tim~ Water
........
TE~T RUN BE]WEEN ~ FT AND '
..... . ....
I ~-- CERTI~HAT THIS TEST
GUIDEL1NESIN EFFECT ON ~HIS DATE. DATE:
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825"L"Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
November 15, 1994
Tippah Trust
5631 Silverado Way, Suite F
Anchorage, AK 99518
Subject: Tract A, Overlook Estates
Pernfit #SW930449, Parcel ID #068-041-14
Dear Tippah Trust:
The subject permit, issued October 16, 1993 by this office for a single family well and/or on-site
wastewater system, has expired as of October 16, 1994.
A new permit must be obtained from this office for a well and/or on-site wastewater system NOT
installed by the expiration date.
If you have drilled the well, a well log must be sent to this office for documentation of the
installation and to close the permit.
If the on-site wastewater system has been completed and a licensed Professional Engineer has
inspected the installation of the on-site wastewater system, the original as-built inspection report
must be sent to this office for review, approval and documentation. All inspection reports must
be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00
for a well permit and $440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sincerely,
James Cross, P.E.
Program Manager
On-Site Services
JC/kb
CC: ~a . . ", . ~
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW930449
DESIGN ENGINEER:BUZDOR ENGINEERING
OWNER NAME:TIPPAH TRUST
OWNER ADDRESS:5631 SILVERADO WAY, SUITE F
ANCHORAGE, ALASKA 99518
DATE ISSUED:10/26/93
EXPIRATION DATE:10/26/94
PARCEL ID:06804114
LEGAL DESCRIPTION: OVERLOOK ESTATES TR A
LOT SIZE: 999999 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
DATE:
DATE:
· EBA Engineering Inc.
Geotechnical and Materials Engineers
October 20, 1993
0941 0280
Municipality of Anchorage
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK 99519
RECEIVED
OCT 2 1 199
Municipality of Anchorage
Dept. Health & Human Services
Attention: Mr. Dan Roth
On-Site Sewer Application
Tract A, Overlook Estates, Alaska
Dear Mr. Roth:
This letter is to address your concerns for the On-Site Sewer Application at the above
referenced location. We are resubmitting the application paperwork with the following
modifications or explanations:
Soil logs and percolation tests are provided on department forms.
Soils Log-Percolation Test forms and Proposed Septic Design Plan View bear
original engineer's seal and signature.
There are no wastewater disposal systems, wells, surface water, drainage courses,
roads or structures within 200 feet of the proposed wastewater disposal system.
The plan view has been revised and additional cieanouts have been drawn for your
benefit.
The application is for a new wastewater disposal system only. This is not a
replacement system and no wells have been installed in the immediate vicinity or
within 200 feet of the proposed site.
The plan view has been revised and additional cleanouts in the absorption field have
been drawn for your benefit.
An additional percolation test was performed and the plan view revised to show this
location. The disposal field was shifted slightly to encompass this testhole. The Soils
Log-Percolation Test form is included with this submittal.
A plot plan of Tract A, Overlook Estates was included with the submittal to show location
of the test holes and proposed house location within the 35.4 acre tract. It is our
understanding that this is the second on-site wastewater disposal system application for
this tract. Separation distances from the proposed system to all adjacent systems exceed
500 feet and impact on adjacent systems and property is assumed to be negligible.
907-East Dowling Road, Suite 27, Anchorage, Alaska 99518 ~C~
· Telephone (907) 561-4085 · FAX (907) 561-7071 ·
. 0941 0280 Page 2
Reserve area for the tract is approximately 1,540,000 square feet. Slope on the tract
averages between 25 to 30 percent. Slope in the immediate vicinity ef the proposed
drainfield site runs between 15 to 25 percent. Contour lines are shown on the site plan
and plan view.
Design of the absorption field follows requirements specified in the Anchorage Municipal
Code Chapter 15.65. A design sheet is included to show trench options and design
criteria. A five foot wide shallow trench with a two foot effective depth is specified on the
Proposed Septic Design Plan View. The minimum trench length is 79 feet and the
maximum depth of the trench is five feet below the original ground surface to maintain an
approximate 4.5 feet separation between the bottom of the trench and the ground water
table, These specifications are also shown on the plan view. The system installation will
follow requirements specified in the Anchorage Municipal Code Chapter 15.65, required
in accordance with the On-Site Wastewater Disposal System Permit provisions.
If you have any questions or require clarification, please feel free to contact me at your
convenience.
Sincerely,
EBA Engineering Inc.
A. Smith
Project Engineer
Attachments:
On-Site Permit Application
On-Site Services Fee Documentation (copy)
Soils Log-Percolation Test Form - Test Hole No. 1 (original)
Soils Log-Percolation Test Form - Test Hole No. 2 (original)
EBA On-Site Design Sheet
EBA Proposed Septic Design Plan View (original)
Overlook Estates, Tract A Pict Plan
On-Site Services Transmittal Sheet (original)
DEPARTMENT OF HEA~TH & HUMAN ~ERVICE8
L~AL DESCRIPTION'~ ~ ~-~ Tow~ohlp, Rang~eOtlO~;
~ :, SLOP~. ~IT~ PLAN
PERFORMED
4~
$
7
I0
12
13-
14
15
10
17
18-
wAS ~RDUND WATER
ENOOuNTERED? ~ __
DEPTH?
'1
Time Time Wate~ Drop
ACGORO~CE WITH ALL ~TAT~ AND MUNIC PAL GO DEL N~$ IN EFF~T ON TH[$ OA?~' ~T¢ ~.. ,~ ~
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION~T¢'c~C-'¥ ',J~ I (~""~'~'~C~4- ~ '~'
Township, Range, Section:
(FEET)
SLOPE
-/
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18-
19-
20-
WAS GROUND WATER
ENCOUNTERED?
S
L
IF YES, AT WHAT O
DEPTH? p
E
Depth to Water After_.
Monitoring? c~ ,$ ,~,L Date:
SITE PLAN
Gross Net Depth to Net
Reading Date
Time Time Water Drop
PERCOLATION RATE ~, (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~'~/'~ FT AND -~ 'f~' FT
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
RESIDENTIAL ON-SITE DESIGN SHEET
SINGLE FAMILY DWELLING
MUNICIPALITY OF ANCHORAGE GUIDELINES
EBA Engineering Inc.
Phone: (907) 561-4085 907 East Dowling Road, Suite 27, Anchorage, Alaska 99518
Fax: (907) 561-7071
DEEPTRENCH
SHALLOW TRENCH
PROJECT NO: 0941 0280
CLIENT: FREDRIC B. FORTIER
SITE LOCATION: EAGLE RIVER VALLEY
LEGAL DESCRIPTION: TRACT A, OVERLOOK ESTATES
SEC. 25, T14N, RIW, S.M.
NUMBER OF BEDROOMS: 3
MINIMUM SEPTIC TANK SIZE: 1000 GAL
PERCOLATION RATE: 6 MIN/IN
DEPTH TO GROUNDWATER: 9.5 FT
BACKFILL TO ORIG. GRD. SURFACE: 2.5 FT
WASTEWATER APPLICATION RATE: 0.8 GPD/SQ FT
WATER USE PER BEDROOM: 150 GPD
ABSORPTION AREA REQUIREMENT: 563 SQ FT
OPTIONS:
1.5 FEET OF ADDITIONAL FILL REQUIRED OVER LINE
DEEP TRENCH
EFFECTIVE REQUIRED TRENCH
DEPTH (P-r) LENGTH (FT)
4
4.5
E
5.5
6
7
8HALLOW TRENCH
'nRENCH REQUIRED TRENCH LENGTH (F'F)
WIDTH (F'F) O ~ 6 IN I FT 2 FT
2 281 225 161
3 188 156 117
4 141 121 94
5 113 98 79
* TO Close To Groundwater
3FT 4FT
COMMENTS - DESIGN CRITERIA
SEPARATION DISTANCES FROM PROPOSED SYSTEM
Water Well - 100 ft +
Property Lines and Buildings - 10 tt +
Adjacent Systems - 500 ft +
System piping and lank must be installed following 1991
Uniform Plumbing Code requirements.
Minimum two comparlment septic tank size Is 1,000 gallon
capacity. An additional 250 gallon capacity is recomended
if a disposal or garbage grinder is used in the residence.
Install filter fabric over the sewer rock, including areas
covered with solid Insulation.
Trench should follow site ~ntour.
Reserve area is adequate - 1,540,000 eq ft lot size.
DATE PRINTED 7/23/93
SHALLOW TRENCH ABSORPTION FIELD DESIGN
2 Ft Effective Depth - 5 Ft Trench Width - Minimum 79 Lineal Ft of Perforated Drain Pipe
/ -- Cleanouts
Cleanout
Test Hole No. 2
Location ' ' ' ®
/
\ :'-
"-A ,.-.,-.._.,.~.~ .....
30 ft Test Hole Radius
Proposed House
Location
786
784
782
--,:--_---_-'~'~,--~ ~ ~ '~. 780
Monitor Tube '~,, ~ ~, ~ .....
\~ ~. ~.~ 778
Trench \~. .... 776
~' ~-.~ ~..-- ------- 774
',-- ..... __~ - 772
Monitor Tube
_.---. --'-' 770
Cleanout ....._........---'-" 768
Hol~'~: 1 ' 764
Location
'~"' Reserved Replacement Trench Site
5FEET ~ (~..~__ ~ FIL~I~RFABRIC
ROCK NOT TO SCALE
Tract A, Overlook Estates, Eagle River, Alaska
Plan View - Proposed On-Site Septic System Design
Project No. 0941 0280 10/21/93
EBA Engineering Inc.
907 East Dowling Road, Suite 27, Anchorage, Alaska 99567
Phone: (907) 561-4085 Fax: (907) 561-7071
SCALE: 1 Inch = 30 Feet
Z
0 z
' 0
u.I
,.,.- 0 0
LU '
uJ ~ 0
> 0 'l-
Z n
k