HomeMy WebLinkAboutP & S LT 5Onsite File #015-142-41 06/11/25"13 23:41 9ei?-345-•-_J'20'2 AL_PINL UNILLih:G Nt'UE W/U1. :alpine Driffing & Enterprises Well Log raxaii± I4r'taat 4 ea': ti 'i 9_l '2" $�itte crfi >tsstae; -2 -7J Parcel identification Number: 01514, 4`l000 Date Started: 9-25-13 ,Date Cmmplete€i: 9-27-7-9 is well located at approved permit location? x Yes Ll No Legal Description., P&S Lot 5 Property 0wxier Name & Addm ss: C%hl'istina Hutten 5140 F I1?th Ave Anchorage, A!aska BorebOe Data: Soil Type,-Mickress arc 'Eater Strata stick.-vp organirs ct: Silt b�rrvallj� gilt sratrdy silt silt gravelly silt silty grcnel silt sanriy silty -K ater & gravel silt graxvelll, sil; wet slW4, water sand & gravel Depth (ft) Frorn To G ro 3 i2 41 44 81 3 149 11i I9 1161 2 z 12 ,11 44 81 33 89 illi j1 7 .Irl 107 ft; ER QUALITY TESTING Collbrrn eA C01/100mL '(WI, NitratesN D L ArsenicND W/Lof 15l 'I I,[ Fla H"sup- D Method of Drilling x rir rota -q ❑ oable tori. Casing type: steel Wall Thickness -.250 inches Diameter: 6 iticbes Depth: 167 feet Liner 1),pe: ,-- Diameter: _ inches Depth: _ feet �C'aslla stie9ku above ground; 2 %et - - _-- — StR,tic water level (ti-om ground level): 77 feet 'Fumping level: 1 g feet a�cer l7Atrs pumping 10 gpm I Recovery R ate: 10 gpm Metlwd of Testing: air 1O Well IntAe t?pelrlexg Type: x Open Rud ❑ Open Hole 0 Screened Start neer "Stopped feet t Ej perforations Start feet Stepped -- feet Grout Type: bentonite•cam riles Volume, 2 bgs Pump: Intake Depth - - feet — Pump size hp Brand Name ___ Well 7lDisinfeettsl TJ pon Completion? X y vs Method of Dislufeetion. Chlorine tatlets 111 a Comments: Well Driller; Alpine Drilling & Enterprises NO Box 11049E Anchor•azge. f4]i:9.9511 U0! LI 1 :1 'j.L UO .---..Z0«, MUNICIPALITY OF ANCHORAGE 904 oeveiopnient Services Department P! P07-13-7 99 7 On -Site Water & VVastewater SOctir Fax 907-343-7 ptlynp Iristallation Log Well Drilling Permit Numbwr, 1,01423 Date, of Issue: 92719 Parcel Identification Number. OIE-141.41WO ri,operty owiier Name & Address: Viistlne HuMn 52140 E. 112th AVe Anchornae. AK 13V516 Pamp Installation Date: _2019 160 F111tip Intake Depth Belvw Top Of WL�ll feet ,v,uinp Manufactartr's Xmite: Goulds Pump Model: 10SH07 ptimp Size: 3/4 --hp Pidess Adaptec- Burial Depth.. NfA_.- feet Pitless Adapter . ManufactUrer's Name:/A Pitless A&apter Igst,01erNIA Well Disinfected Upwa CompletiOn? 0 Yes '-I -NO *Nfethcd of D4111fectitin , cn!-:)trp. tablets Comments* PLEASE SAVE FOR C05k Pitaiap Installer Company.*ALP'NE DR'LL'NG & ENTERPRI. Iv ailing Address- P.O. Box 110496 CRY: Anchorage Suite: AK Zip: 99511- Attention. 9511- Attention. The punlp in,�tajjer slia.11 provide pump irsta114t'.ern ,'j)gj,) wirbin 30. deys )f rjurnp inl,�Mllati011. 7 om Ub/ I Z: -i a-'Ui J LU: UJ ti U Z11 - L9 -.' Ll U I i U11 MUNICIPALITY OF ANCHORAGE DEMOPMENT SERVICES OEPAPI' 907-343-7904 On -Site Water �mdWastmate r Se t a Fax: 343-7997 www.muni.org/onsite Subdivision Block __ Lot T l Rp.rflrm fn� On -Fite WRtCF &Nziatmvaker section ;Ftfled w.niractor performing the well decommissionircy K"d n e: Duv.'d Harper CoMpany: Alpine Orilling & Enterprises Well decomrnls&ionjrgdatp- 9-27-19 Nlethod a° Cecommi-,ubnirg AMC' 1 b-55-060LI 0, ❑ b. Location; Use the Gpac-, to provide a drawing -3f the pF)rer(y ZKI)-Niig the f011owng items- • Ninth arrow • Dammmisuioned w6l] jouatjorj Location c'o!hw water wsijs an tije property • Two separate ming -tie distances f0t gach %velt r:Mwn on the drawing Neta: The swing -tie distances sheai be MGaLvred front 91ther pe:m..anr:srrt structures ur the pn)puqy comers. Site e *2Mr MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191423 Work Type: 0eII .Upgrade Tax Code Number: 01514241000 Site Legal Address: P & S LT 5 G:2637 Site Mailing Address: 5140 E 112TH AVE, Anchorage Owner: HUTTEN CHRISTINA Design Engineer: This permit is for the construction of: ❑ Disposal Field Cj Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: Lot Size in Sq Ft Total Bedrooms: ,, X11 C II_j I 1) e P a I- till e 11 t C( /Z3/`1 9/19/2020 21753 d Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: To close this permit please submit: 1. Well Log 2. Pump Install Log 3. Water sample results 4. Well Decommissioning Log Received Issued By: i Date: < Date: / K, n MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 016 - ° Property owner(s) ��%�/�' /� /U� T/ (i/%/�J Day phone Mailing address /� 0 � / c� ;� Site address 791V ala2 7z -a(2— 775-16' Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) 5 - L_o-�- 5 Lot Size Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION 1S AN: TYPE OF DWELLING: (® all that apply) Absorption. Field ❑ Initial ❑ Single Family (SF) [� Septic Tank ❑ Upgrade (w/wo ADU) Duplex (p) ❑ Holding Tank El Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. . (Signature of pro authorized agent) Permit/Rush Fees: t 13S = 36n Date of Payment: q -10 - ttl Receipt Number: agg11o2 Permit No. 5 91gZ3 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc - o CD 1 A 11 0 31 '.) ,y� �� R�00 N 00°0t 00" 150.00' f.�.. U= 3 91> O O •o � �- ado CD d J` 1, lar 0 10' U Ility Ees ent------1 C'' :;i:# � —��o N 00'0 0 W 150.00' o �V1�ki i 16 �V o .C? NJ�v _. 0 z c v m 5.4' > �QY C U A 4.8' o �NQ 4.0 0 v o=c O on W uq c m ^ M N Q+ w o d p -C 10.0' II O ° — a_uLnQ_. N a O c Q c 3 c .o O 3 U a E aj z 4.0 t -cCL O v o� o Q) � p 0 O .L o _ O In YLn Q)O c -c ^ C. c — v E3 �`° 'a N O '''`^ Y > 7 4.0' _ 0 �° '03 0> o :3 o v n Z t(i �- j- Q c0 N c v1 C to ° z -c E Y o Iv Q� H a,c `o — 8.5' S' v Q �� 0- � 0@Q m 4-f: 8• Gi v �� `�� a� LIQ -a l p O Q N co u- ra N Q 'Qu) d M O <} O v v c z U• O u y a ocn U N 5 _ v c o Q Q O u� y w@ c 0 N - N > F a 3 Z v a v ° U 24.2 I y � 6 ��C\j u 'o v a@ v az N }C'l o '� ° w o ��? u°o v c-0 :x o L • v--------._ _ .--- --.. �— _ Q ^O w. . > -a!a x m N u e a)[ QX N 1 z p 'Z �OX :-IAI2NQ 3HOI^dO> W Q o! m z LO — a Qalo� N 00'04'00" W 150.00' m N r."J s'i LL G0 �9Y? ct • O�w z N J i N i�' A JQv Q QJ d a) Ob 69�. r — En Y` uKX ,o 3 p M y o ! O aai N o n O ! p LQ b b Z �Mani�6 Z9 4 oAEr 0 AW NW �� �. 10' Utility Easement Side N 00'04'00" W 150.00' ®� o ® U. r� C)) 3:1 I Q j t; 33' 01 v (�b ' AwI ®® P&Ztd 5/i 1 iy Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Mark Begich Anchorage, AK 99519-6650 Mayor wmw.mumarg/onsitz (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW Date of Issue: Parcel Identification Number: Legal Description Property Owner Name & Address: ` ocive,0 /heslt�2tS F Pump Installation Date: 41 -a q -i41 Pump Intake Depth Below Top of Well Casing: %g feet `^ Pump Manufacturer's Name: �F�i��►CKC� Pump Model: 50 G 3 i ( 05 tike Pump Size r/#, hp Pitless Adapter Burial Depth: /a feet Pitless Adapter Manufacturer's Name: -� Pitless Adapter Installer: �— Well Disinfected Upon Completion? Yes ❑ No Method of Disinfection: Comments: a Pump Installer Name: ANCHORAGE WELL &PUMP SERVICE, INC 330 EAST 76TH AVE ANCHORAGE, ALASKA 99518 (907)243-0740 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. �_ a MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME / PHONE ❑ NEW E MAILING ADDRESS 2�C1 LEGAL DESCRIPTION 01 LOCATION NO.OFBEDROOMS Well d— Absorption area Dwelling PERMIT IVO. L) Y DISTANCE TO: e-00,5 / _ a za Manufacturer Material No. of compartment WF rn Liq. capacity in gallons IF HOMEMADE: Inside length Width Liquid depth 0 Y DISTANCE TO: Well Dwelling PERMIT NO. J � Z _ Manufacturer Material Liquid capacity in gallons O w= DISTANCE TO: Well I Foundation , �'ci Nearest lot line / .5 PERMIT NO. J LL z No. of lines Length of each line Total length of linep / Trench width Distance between lines H Z LU 74 inches cc� Top of tile to finish grade 7 Material beneath theTotal �i� S effective absorption area o 41 rtes /v Length Width Depth PERMIT NO. Lu c7 Q F Type of crib Crib diameter Crib depth Total effective absorption area as Lu LU Well Building foundation Nearest lot line DISTANCE TO: J Class Depth Driller Distance to lot line PERMIT NO. J W � DISTANCE T0: Building foundation Sower line Septic tank Absorption areas) Y OTHER PIPE MATERIALS SOIL TEST RATING '� s-0 INSTALLER - REMARKS - zl /xe/ r U D, APPROVED DATE LEGAL 7�c /U—/V—�G 71-013 (Hev. 3/78) �✓ r-1 n..J t -j I A._ - 1: F=• t•=-1 L_ I i °'P C-1 F F::= t -A r'_="� �A F'"A..� F= DEPARTMENT 0: HEALTH AND ENVIRONMENTAL F OTEC T I F_ N � 25 'L_f STREET, ANK. CHORAGE, A {-4720 `�`a•� l t — !D- xO c PERMIT NO. 800571 0571 wtf.u--n 4 APPLICANT HANK PECK ST RTA E:OX%_•.tv 4—L I 2.� € i � ��:i�j: •t - �'L� LOCATION EAST 1.12TH AVE. LEGAL LLT 5 P&L. SUB J 111/ LOT . 27580 SQUARE FEET TYPE OF SOIL IL ABSORPTION SYSTEM I =• : TRENCH /C); 'o"S U t'iH;>;Itiilpi pallPiEEF: OF EEL:F:OOt'!_ = SnIL RATING ;SO FT,iEE::r= 50 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM I S, : THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD, THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET::. THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS. THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL F'IF'E AND THE BOTTOM OF THE EXCAVATION IN FEET?. F= F. ems! 1_ R : F= L =" • 1� F= T A "i- n N 6-==_ !E-l=F= PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENC:E`_ THAT THE WELL WILL SERVE. — — — i 1-• 9 A�e s � :2 > ?t �'�• F—` ®� = —f e.®t .@ n F ~• F F F= !�a l_e T F-. r_= c- — — — BRCKFILLING OF ANY SYSTEM WITHOUT FINAL IfidSPECTION AND APPROVAL BY THI_• DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON—SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC: WELL. MINIMUM DISTANCE FROM H PRIVATE WELL TO H PRIVATE S•E14ER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE I'S 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F='F= FF° M I T F= e A F=' I IR_ E: *H. CA F= A_: E=_ M E?. E: Fv =z -1 o I "=8 CE"• Fr_v I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON—SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. L: I WILL INSTALL., THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON—SITE '=EWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS. S I GNEGZJ3�drL.a6�_ _�---------------- APPLICANT ---•------------- APPLICANT HANK PECK 1 SSUED V4. 0 SOILS LOG, MUNICIPALITY OF ANCHORAGE y�\ 'I DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTIONEl PERCOLATION. TEST' t9� Pouch 0656, Anchorage, Africa 69562 276-2224 SOILS LOG — PERCOLATION TEST (see prior dated 9%/880} PERFORMED FdR: 'C0 Ae44 !rL/DATE PERFORMED: OLT. -7, 19fJ� LEGAL DESCRIPTION: Lo- .a L SUbd/Y/5/Or! 11z'AA Ale. DEPTH - - _ SLOPE SITE PLAN -- (FEET) V L� ,� j � I --��IFi I � I I _ 2 —i—fi —� f 5 j j ! QD 1- 6 ; -- - i --- i r- - - 0 I v 9 - v b � v ey WASGROUND-WATER ' ! i 11 ENCOUNTERED? /V O L O 12 .��Y'7%mv3/f/y -Sums/ P......k - d E N01A/ -SV;7 � q`yL IF YES, AT WHAT 13 16i# S�/'B�Qh* S.DEPTH? ).._ i- _ gn9u/air^ Reading M cohh/eS AD 2 ', 14 Depth to Water Net Drop - - Bo7Ti7rn off' ho% 15 . 1s of 4L ls�. 17- 7a18 / 18 •C L'J f ' 0. 00 N .. _ 19 .. • • a s.. .. , n� NO I'M E Reading Date Gross Time Net Time Depth to Water Net Drop / M" SOILS LOG MUNICIPALITY OF ANCHORAGE , DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6650, Anchorage, Alaska 93502 27,f5 2221 SOILS LOG — PERCOLATIOW TEST PERFORMED FOR: Ae DATE PERFORMED 7% LEGAL DESCRIPTION: 2 3 PERCOLATION TEST SLOPE SITE PLAN - F t�DEPTH E ZEA�jj) 14L /VZ. 13 14 15- I 16- 17 — 18 19 20 COMMENTS braenn loam, bCc®17749S T gray Inh t j7ray 74an anavel ens and gem'v 'v '?)wy 'Fundy S;//, dine Si/ Sa'0701 40 4l/ ,0reWr WAS GROUND WATERS� L ENCOUNTERED? /VO 0 an 7,16a' P ? I IF YES, AT WHAT E DEPTH? Gross Net Depth to Net 15-E 9 Reading Date Time Time Water Drop 6 2.) -36, le 174' 2:40 7, Oep /0 Z. 50 7-3/ /0 0,44 3:oo 7.75 PERCOLATION RATE 30 (minutes/inch) TEST RUN BETWEEN _zo_ FT AND FT _ PERFORMED BY: E�6wshaw CERTIFIED BY: 72-002 (7/76) DATE:. 1w SOILS LOG = MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST Pouch 6650, Anchorage, Alaska 99502 276-2221 SOILS LOG — PERCOLATION TEST PERFORMED FOR: 'r/yDsa/% DATE PERFORMED: !E5 /. �8 //pQ LEGAL DESCRIPTION: �7� S10 SLOPE - SITE PLAN DEPTH - •/ I --i--- 1 MLM2- /Vi- 3- Mi -3 - yray- Ian yrgvp//y- 4 c M -�-- — f -- om N 7 0 /y 14 -fray- fan SAY c�ya a/ o{� caorse o%n �� and y�ve�/y sA.�d, -fray 5"'dy s;//, 0n0/ Rine si/y%y se j no 4pVa WW/- WAS GROUND WATER bedding' ENCOUNTERED? Cobb/�S and, [•�"u�dNAs 7� 'L IF YES, AT WHAT w DEPTH? y�gdarrr . Bo�i'Cv» o�'hole NO. Y515 -E to s L O P E Reading. Date GroEe( TimpM' Net Time h7;n Depth to Water Net. Drop��� 20 .7 2:40 7.0ly - /o O. ZS Z: So 7.31 /0 0, l— -QVI 3 : oo 7.75 .I /0 _t LI¢w 31,10 8,04 )I r— Reading. Date GroEe( TimpM' Net Time h7;n Depth to Water Net. Drop��� 20 .7 2:40 7.0ly - /o O. ZS Z: So 7.31 /0 0, 3 : oo 7.75 /0 31,10 8,04 2() -[ PERCOLATION RATE.79 � (minutes/inch) try.TIVST RUN BE 10 FT A/ND �'� FT COMMENTS. �G��/iJJ19�/%Cf cry hoI 42 0 K '? ✓�' � •5� �9 PERFORMED BY: A. �. o wshawc/%. CERTIFIED BY: 3604 -/8/4 72-008 (7/76) frvy. u. �� 77- �, 6tayl O'k 't ,�t 6 0