Loading...
HomeMy WebLinkAboutNORTH WOODS UNIT 4 BLK 17 LT 1North Woods Unit #4 Block 17 Lot 1 #051-064-50 8c- F Municipality of Anchorage Page I of 2 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 0 Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW49o171 PID Number: !IS/o�4so Name: Wastewater System: 2�New ❑ Upgrade kop,7-owency Address: ABSORPTION FIELD 70q W. ZUi Ei ri0,u ac as P,0, *7-00 Rhone No. of Bedrooms: Deep Trench ❑Shallow Trench ❑Bed ❑Mound ❑Other ve"a? 4 A 995/? --//23 3 LEGAL DESCRIPTION("Ig- Soil Rating: Total Depth from original grade: .t15 GPD/S . Ft. �'S Lot: Block: Subdivision: Lot: Depth to pipe bottom from original grade: Gravel depth beneath pipe 1 17 A)0XTY WOO 4>S S/,A AJ, - Ft. . Ft. Township: Range: Section: Fill added above original grade: Gravel length: Ft.'- /17 Ft. WELL:❑New ❑ Upgrade pg Gravel width: Number of lines: Distance between lines: • S Ft. 2. /Z» Ft. Classification (Private, A,B,C): EXIST Total Depth: Cased To: Total absorption area: _ Pipe material: F P/o 111CP_F (fom vtU,cJ/TY Ft. Ft. / O%3.3 SOIL As-ro? /73032 Driller: Date Drilled: Static Water Level: Installer: Date installed: Ft Oct140M&-S- -ZS-9y Yield: Pump Set at: Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES Oseptic ❑ Holding ❑ S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines � (7 -p_,56 -A 7,—qAj.#- /Z.Sa t Materials Number of Compartments: Well' 2�',F ZM (t — ZS + TEEL 2 Surface -- LIFT STATION WatLotS¢ Jodi-/-/L)0'+- Ilons: Manufacturer: Line /0't /0 ,IL --~ -- "Pump on" level at: off' level at: High water alarm at: Foundation /t7 r ) 7 1 _._„ ___, Curtain AWAJ 6 KNd WA) Pump Make &Model Electrical Inspections performed b . Drain BENCH MARK Remarks: Location and Description: T ,4 lr l4z.4. Assumed Elevation: /OU.Oa Ft ENGINEER'S SEAL �t ew Ajar O?;,5 ti �1 S & S ENGINEERING IM4 Eagle River Loop Road, No. 204 Inspections performed by: F glA River, Alaska 99577 Dates: 1st 6; -2v-94 2nd -2s-9N ALM..,A. 4.1- , Department of Health and Human Services approval u Date:¢ Reviewed and approved by: ��!sv av—[-1 72-013 (Rev. 9/91) MOA 25 Permit No.SW940171 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report NORTH WOODS SUBDIVISION, UNIT IV, 05106450 Legal Description:BLOCK 17, LOT1 PID No.: pCp01 CpO2 FINAL GRADE; II i-98.4' H ':; �C04�am1 97.9' 97.7 Co' 94.91 1000 GAL SEPTIC TANK N.T.S. SEPTIC co SCALE I" = 40' 72-013 A (1/93)' T BDRM 94.1 R94.0' ............................. I............... 90.4' 90. A84.4':NO WATER MT2 FCO 19.5 20.0 — 001 23.0 23.0 — 0O2 28.0 28.0 — 0O3 63.0 37.0 — 004 — 29.5 'i16. C0.5., .82.a 54:0..1...._... C06 — 34.0 36. MT1 — 25.5 `17. 1am9 — aP F as kr q tt PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE �Lkp l DEPARTMENT OF HEALTH AND HUMAN SERVICES Lo_aLi_c14 P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940171 DATE ISSUED: 6/09/94 DESIGN ENGINEER:S & S ENGINEERING EXPIRATION DATE: 6/09/95 OWNER NAME:NORTHWOODS INC OWNER ADDRESS:709 WEST INTERNATIONAL AIRPORT RD #200 ANCHORAGE, ALASKA 99518-1123 PARCEL ID:05106450 LEGAL DESCRIPTION: NORTH WOODS UNIT IV BLK 17 LT 1 LOT SIZE: 35886 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) . 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED ISSUED BY: BY: P DATE: / DATE: May 18, 1994 ROBERT SHAFER, P.E. ROGER SHAFER, P.E. CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 HEALTHAUTHORITY APPROVALS Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 'L' Street P.O. Box 196650 SEWER &WATER Anchorage, Alaska 99519-6650 MAIN EXTENSIONS REFERENCE: Northwoods Subdivision #4; Lot 1; Block 17 SEWER & WATER INSPECTION Request you issue a permit to install a septic system to serve the proposed three bedroom house on the referenced property. ENGINEERING STUDIES ANDREPORTS Test holes were excavated and percolation tests performed. The approximate locations of the test holes are located on the attached site plan. The monitoring tubes within the test holes have been WELL INSPECTION checked and found to be dry. & FLOW TEST This property has enough area for a future septic upgrade which can be seen on the attached site plan. SITE PLANS This property is served by a Community Water System. We do not anticipate any adverse effects on neighboring properties by the installation of the proposed septic system. ROAD DESIGN If you have any questions, or require additional information for your review, plea ontact us. Sinc ely, SOIL TEST o A. Shafer, P.E. PERCOLATION TEST �LSU�]k STRUCTURAL& MECHANICAL INSPECTIONS ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 r x ,'I- CY) Q) W N w w r Q O LL w NJ oZ 0 Ld w Q: CY c d O f -w O 00 Ln to '- oulCE O �--i1\ i]OLnO W ro V) It Q w WhE- 0 O Lo t 9 � 3 �I Y3 @) I� x e p eJ w N o 9 War 0�wy r x ,'I- CY) Q) W N w w r Q O LL w NJ oZ 0 Ld w Q: CY c d O f -w O 00 Ln to '- oulCE O �--i1\ i]OLnO W ro V) It Q a I I E- P, . P z w 0 zI v' o � I �. Zz wo Oo of a x �0 U_�4a� 'o I. 0 I C67 x0 >r�� Ca a O aN CL- Z,< w I o .O wowm O O U¢ NONd h Z •-� w O I W�mZrLi wz mwr W Oa �az��» �I > oQz<woo�- Oua 0 I Z��» W NJw I a WhWV) t--0 F—Z ' Q. I U) wozwa OFa Q(q OZOwO U00 I E- V) — a- U) z -HN—a-UIz CLI 4 WZ�J�Ui W ZF--O� OI mom' =L,wv �0IL I-ZI Zm �I at V1 jFlN w Brio¢ O -00I ILOP a C)I I O V) 'I I z 0 H m m 00 O J (). MIN. NVId IIS 31vos w WhE- 0 O Lo U] @) ��z Z w N o a W r"wz 0�wy w wPTA LU 0 C4 w ��w I W Oa �i 1--W w l El a I I E- P, . P z w 0 zI v' o � I �. Zz wo Oo of a x �0 U_�4a� 'o I. 0 I C67 x0 >r�� Ca a O aN CL- Z,< w I o .O wowm O O U¢ NONd h Z •-� w O I W�mZrLi wz mwr W Oa �az��» �I > oQz<woo�- Oua 0 I Z��» W NJw I a WhWV) t--0 F—Z ' Q. I U) wozwa OFa Q(q OZOwO U00 I E- V) — a- U) z -HN—a-UIz CLI 4 WZ�J�Ui W ZF--O� OI mom' =L,wv �0IL I-ZI Zm �I at V1 jFlN w Brio¢ O -00I ILOP a C)I I O V) 'I I z 0 H m m 00 O J (). MIN. NVId IIS 31vos ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Northwoods Subdivision #4; Lot 1; Block 17 GENERAL: 1. The scope of this project includes the installation of a 1000 gallon septic tank and two 5' wide drainfields to serve the proposed three bedroom residence located on the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4' of cover shall be insulated. Page Two Northwoods Subdivision #4; Lot 1; Block 17 May 18, 1994 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10' from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENM/DRAIWIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (roughed -up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter and installed approximately in the locations shown on the design. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. Page Three Northwoods Subdivision #4; Lot 1; Block 17 May 18, 1994 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. Ali leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Page Four Northwoods Subdivision #4; Lot 1; Block 17 May 18, 1994 Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST ////1 PERFORMED FOR:C/FT SCAJ-7'r-tZ, 7. LEGAL DESCRIPTION:U16Ue 4L$k Gj-S `7O I Township, Range, Section: �ili(pA-NIGy SLOPE SITE PLAN ----- _- 1 I•I • 2 �'• 3 4 5 6 7 r 8 r 9 0 w% LI -776Z Gvwrf- 10 WAS GROUND WATER Nb ENCOUNTERED? 11 CC/�` of I,PI. S IF YES, AT WHAT p 12 ' DEPTH? P Depth to Water Ager 13 Monitoring? (L� Date: 5 `1 14 15 16 17 18 19 20LJ IL_ JI PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEENGFT �ND Lf FT COMMENTS 5 & S L" 17Ri11YGG/E1'Tv PERFORMED BY: 17034 Eargla River Loop Road No.20 ff6� pp�,� Alaska 99577 // ACCORDANCE WITP'r9'cSTXf'AND MUNICIPAL GUIDEtrf 72-008 (Rev. 4/85) 111 ��� CERTIFY THAT THIS TEST WAS PERFORMED IN ON THIS DATE. DATE: ry y (ENGIN SEAL) e +.� Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 ,WN! A, '1'4 - SOILS LOG — PERCOLATION TEST au PERFORMED FOR: DATE PERFORMED: LEGAL DESCRIPTION: L11 ,�C)j fr jtA1QU� /o bl�n'Township, Range, Section: DEPTH SLOPE SITE PLAN . 4 2 < St6,y Sr4ra� w� C IT c 3 CtP�rWr=�• 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS a i WAS GROUND WATER ENCOUNTERED? b�/7r7/f S L IF YES, AT WHAT O DEPTH? p E .0. f- Depth to Water After g��`� Monitoring? t " Date: sl-• 94 Reading Date Gross Time Net Time Depth to Water Net Drop 1 ESd k—P, 10 53114 YL/ .� 1V Y Vit II PERCOLATION RATE 4{Q (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN AND 11 FT J C[J Y.W.. • PERFORMED 817034 Eagle River Loop Road No. 204 Eagle River, Alaska 99577 // ACCORDANCE WITH ALL STATE AND MUNICIPAL GUI13 72-008 (Rev. 4/85) CCC��� V CERTIFY THAT THIS TEST WAS PERFORMED IN ON THIS DATE. DATE: Municipality of Anchorage On -Site Water & Wastewater Program (907)343-7904 - CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-064-50 Expiration Date: Sy✓ "� �n 1. GENERAL INFORMATION U,n+� Complete legal description NORTH WOODS SRP.#4; BLOCK 17, LOT 1 Location (site address) Current Property owner(s) Mailing address Real Estate Agent 21447 SNOWFLOWER LOOP, CHUGIAK, AK, 99567 JOSEPH & JANICE WERCKLE Day phone P.O. BOX 670548, CHUGIAK, AK, 99567 Day phone ;dI IICYI:0; 2. TYPE OF DWELLING: SUB j iTAP Single Family (w/wo ADU) � F-1DuplexJUL 0 7 2614 y ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System Public Sewer ❑ W aiverAlariance request for. Received by: �3 ,,/ COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 52_�. Date of Payment I � Receipt Number b2_5 3_ COSA # OST 1 75O� Date: r s Waiver Fee $ Date of Paymen Receipt Number Waiver # Distance: 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site wafer supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Address GARNESS ENGINEERING GROUP, Ltd. 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK, 99507 Engineer's Printed Name Engineer's Comments: JEFFREY A. GARNESS, P.E. In conducting this evaluation, GEG, LH). attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life ofall wells and septic systems depend on the local soils condition, groundwaterlevels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate ofhow long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE B/ System #1 Approved for 3 bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. Phone 337-6179 Date bedrooms, with the following stipulations: ��LlU�ittiif(((l(ff OF A/yCy/i��xi j ON-SITE G>m r WATER AND �o WASTEWATER o^ oRnGRAM By: Original Certificate Date: �% o The n' pat y ori orage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory 1p- 101191191 l� Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system _ Certificate of On -Site Systems Approval Checklist Legal Description: A. WELL DATA Well type _ Date completed Total depth ft. Date of test Static water level Well production WATER SAMPLE NORTH WOODS S/D #4; BLOCK 17, LOT 1 PUBLIC WATER If A. B, or C provide PWSID# _ Sanitary seal (Y/N)_ Cased to ft. FROM WELL LOG g.p.m. Coliform __-�- colonies/100 ml. Nitrate mg./L. Vinic: ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 1250 gal. Number of Compartments z Parcel ID: 051-064-50 Well Log (Y/N) _ Wires properly protected Casing height (abo n F -W Collected by: Date installed Cleanouts (Y/N) M. 6/24-25/1994 YES in. Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) NIA Date of pumping 10/21/13 Pumper SANITARY PUMPERS C. ABSORPTION FIELD DATA BELOW EXISTING GRADE Date installed 6/24-25/1994 Soil rating .p.d./ rObdrm) 0.45 System type DUALTRENCH Length 117 TOTAL ft. Width 5/5 ft. Gravel below pipe 3.5/3.5 ft, Total depth `7.251' 4'5ft Eff. absorption area 1083 ft2 Monitoring tube YES Depression over field NO Date of adequacy test "5/16/2014 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 4_5 in. Water added 1540 gal. New depth 29 in. Elapsed Time: 170 min. Final fluid depth 24.5 in. Absorption rate >= 450+ g,p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date "'TESTED EAST TRENCH ONLY. WEST TRENCH HAD 33.5' OF LIQUID IN IT ON 5/16114 D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump off" levelel a E. SEPARATION DISTANCES Manhole/Access (Y/N) level at Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lrft station on lot Absorption field on lot Public sewer main Sewer /septic service PUBLIC WATER On adjacent On adjacent lots manhole/cleanout Holding tank Manurelanimal excrete storage areas SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 104 Surface water, 1001+ Wells on adjacent lots 20V+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 101+ Building foundation 101+ Water main 101+ Water service line '10' Surface water 109+ Driveway, parking/vehicle storage 10'+ Curtain drain NONEKNOWN Wells on adjacent lots 200'+ F. COMMENTS NO WATER OBSERVED IN ANY CLEAN-OUT (IN EITHER TRENCH) PRIOR TO, OR DURING THE ADEQUACY TEST. 'PER 1994 COSA BY S&S ENGINEERING, WHO ALSO INSPECTED THE SEPTIC INSTALLATION. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date 6I23/1� (Rev. MUM) 8397Y Aim r zoz m / O�5 w 25 =oma p0 $Ozm A Z 32° 0 2mA m0O z N ��� zo wn � C!• m C0 Q. m m / n N 0,9z r I o O N ? N O C C ICD o Im nO.z m I m o c � OD og O w 0,sz I o oc N I a I O OD o y~0c I m 25 Icag d =!.S.5 � a � NORTH 185.39 jI o v�m I r as ani o� o�00 m,3' m o 0 0 0� yWnb vy Z `\\ m o: 2N �. n m n �'es�3ti Jf 1 1 o D �e� Wd r� N ',•N �•/ -A-9075'. asO. m .0y 3, .� OR 00 x 2 fh w , az0 AW > Awa=g3 oz°> Io a: d� 0h m if f S(m.' . �.� .r 00 s �s 8 rov: : dam w CVO GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS MEMORANDUM 6.18.14 Reference: Northwoods #4, Ll, B17 I completed a 2nd site visit to the referanced property yesterday (6.17.14) and observed (2 -each) an inspection excavation (to the top of each of the drainfields). In each hole, there was what appeared to be original filter fabric. I made a small cut into the filter fabric on top of each trench, and found what appeared to be original insulation underneath. I also took measurements and the grades over the drainfields currently meet the requirements of an insulated drainfield. In addition, the owner provided a dedicated access board on the deck, to access the foundation cleanout underneath the deck. -R.C. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply, and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from my investigation and inspection, the on-site water the Municipality of Anchorage files and from in compliance with all Municipal and State codes, supply and/or wastewater disposal system is ordinances, and regulations in effect on the date of this inspection. q s a S EN91[yt1N,.G Phone 6Q Name of Firm ° Eagle River, Alask 99 77 Address zz ey e Date —L—z-- Engineer's signature ` c ` _ ,tifs jW fr 6. DHHS SIGNATURE Approved for bedrooms. aihp ,0 Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments (f o.U(A Date Z Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: L6< j i3� 17 )�" -ftmsgA Parcel I.D. A. Well Data Well type Q If A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) Date completed Driller Total depth Sanitary seal (Y/N) Date of test Static water level Cased to Casing Wires properly prote /N) FROM WELL LOG Well flow / g.p.m. Pu SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on tot Absorption field on lot 7�o `�- ; On adjacent lots INSPECTION Public sewer main Public sewer manhol Sewer service line Petroleum tank WATER SAMPLE RESULTS: Date B. SEPTIC/HOLDING TANK DATA Collected by: Other bacteria Date installed & -a r-81 Al Tank size 12 sD Compartments Z Cleanouts 6*) Foundation cleanout &/N)� � Depression (Y.� High water alarm (Yi Alarm tested (Y/N) I A Date of pumping '}=r�le-APumper J SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot Zoo t k On adjacent lots '� Foundation /01 To property line /o ' Absorption field /6 ' 4- Water main/service line /0111 - Surface o111 -Surface water/drainage /06 72-026(3=)•Front CONTINUED ON BACK PAGE m z m Z r rn C. J m O ,•�••+. ®co C D r t7 Z Z7 ; o On adjacent lots z ^� Public sewer main Public sewer manhol Sewer service line Petroleum tank WATER SAMPLE RESULTS: Date B. SEPTIC/HOLDING TANK DATA Collected by: Other bacteria Date installed & -a r-81 Al Tank size 12 sD Compartments Z Cleanouts 6*) Foundation cleanout &/N)� � Depression (Y.� High water alarm (Yi Alarm tested (Y/N) I A Date of pumping '}=r�le-APumper J SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot Zoo t k On adjacent lots '� Foundation /01 To property line /o ' Absorption field /6 ' 4- Water main/service line /0111 - Surface o111 -Surface water/drainage /06 72-026(3=)•Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed Manufacturer Size in gallons Manhole/Access (Y/N) Vent(Y/N) High water alarm level "Pump on" level at Meets MOA electrical codes (Y/N) SEPARATION DISTAWE+IfOM LIFT STATION TO: D. ABSORPTION FIELD DATA "Pump off' Cycles On adjacent lots Surface water Date installed U - zs -- 14 Soil rating (GPD/Ft2) 0,45- System type :5,4� L ��,A4 Length III ' Width 5- ` Gravel thickness 3, ,S Total depth Z-5 Total absorption area /. D 9 3 Cleanout present WN) Depression over field (Ya "_ Date of adequacy test "1/.t - Results (pas ail) "i/a for ''�/ Bedrooms Water level in absorption field before test `L After test J��+ Peroxide treatment (past 12 months) If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot 26 0 (J - On adjacent lots Property line 40 i f To building foundation 1-7 To existing or abandoned system on lot On adjacent lots -3a } Cutbank ^f/ Water main/service line /o Surface water /00 l4- Driveway, parking/vehicle storage area /o Curtain drain d1 E. ENGINEER'S CERTIFICATION i certify that / have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signature Engineer's Name 16 0i A 1 C. Caw. Date 3 HAA Fee $ oc Date of Payment Receipt Number �a _ 72-026 (3/93)' Back -ci WBM C. COWAN a e� CE -8601 IAS �+� °•, `� � Waiver Fee $ Date of Payment Receipt Number