Loading...
HomeMy WebLinkAboutPARK PLACE LT 1 Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~-'~L~,~ q"'~OZl~'(~ PID Number: 0~-~ -- Oq~-- Name: ~0 ~T/~. Wastewater System: O New ~Upgrade Address:~[ ~' ~ P~ ~& ABSORPTION FIELD Phone: ~Z ~l~ ~ J NO. of Bedrooms: S'WlOE ~ 0 Deep Trench ~ShallowTrench D Bed D Mound ~Other G~"'~ [~o~F ~.~, ~ro~ o~ig~na~ ~e: LEGAL DESCRIPTION so, Rating: ~ GPD/Sq. Ft. ~ ~ W/~' ~R~O Lot: ~ BIock:~ ~ Subdi~ion:~ ~ Depth to pipe bosom from orig~nalO~~grade: Ft. Gravel depth beneath pipe~, ~ ~ Ft. ~°w"~"~: ~/~ J"~'~:~ ~s~"o,:~ Fill added above original grade: Gravellength: ~ Ft. Ft. WELL: ~t~T~W D Upgrade Gravelwidth: , Numberoflines: Distance~nlin~: Classification (Pri~A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: ~H Driller: Date Drilled: Static Water Level: Installer: Date i~stalled: ' Yield: J Pump Set at: ~ Casing Height Above Ground: GPu ~o~ ~t.I ~t. '~.~.~,P TANK ~'~ SEPARATION DISTANCES n Septic n Holding ~ S.T.E.P. TO Septic Absorption Lift Holding Public/Privet Manufacturer: ~ ~ Capacityin gallons: From Tank Field Station Tank Sewer Lines ~ ~, ~ ~ Number of Compa~ments: Welh' /O0~ /0~ ~00~ ~ ~'~ Material: ~L Sudace Water /00'+ /00'+ ~m~ ~ -- LiFT STATION : Lot Line /~'+ ~0'+ /0 '~ __ ~ Manufacturer: ~C[4. ~ ~ ~ "Pump on" level at: ~ "Pump off" level at: ~ High water.~larm at: Foundation /0 · /0'~ ~0 ~ ~t--~ ~V~ ~ Cu~ain Drain ~O~ B [(~GW~ ~- ~ ~ ~ Pump~Make & Model ~ Electrical~lnspections, O, A pedormed by: Remarks: O~D ~tgTl~ ~y~ BENCHMARK Location and Description: ~ = I0~. ?& ~,..,~ ..... Inspections pedormed by'. ~;~ ~'~'~;a k'~> ~ Dates'. 1st II/~a/~> ~le~": .... -21;~'~'yl;~ ~ [-'~ ~:"a~ Depa~ment of Health and Human Se~ices approval ¢ ~,,,,, Reviewed and approved by:~~ C /~ Date: ,/>~ ~77 a~.<<>~. '~'.,~s<~-",',',,'" ........ __1 A TO F,C,O, = 1,0 ) B TI] F.C,O, = 23,0 A TO MH1 = 18,0 ~ B TO MH1 = 15,5 · B TO NH2 - I B TI] ~;ANPLE POET A TI COl = 57,5 I B TO COl = 584 ~ A TO MT = 72,7 ~ B TO MT = 67,8 t x , " , PREPAEED BY~ ALASKA ~ATER & ~ASTE~ATER 18/4/97 'GROUND OVER FILTER = 101.? ~ ~-M.IN CDVER: 2.75 FEET, /---- SLOTTED PVC PIPE. INVERT = 98,G ' / GROUND OVER TANK = 99,9 ]~---4 INCHES OF BLUE~D~R3 / NIN COVER = 4,6 FEET, /~DVER TOP ~F FILTER. / DRAINROCK FROM TOP OF BL~CK PEA, TO 2 INCHE~ OVER T~P DF 3LDTTE~ PVC PIPE. ~ ~ FILTER. PER ANCHORAGE TANK DESIGN, ~INFILTRATDR CHAMBER (18 INCHES TALL> / ' TANK SET LEVEL WITHIN 01 FEE FOUNDATION C/D ON 30TTDM DF TANK I~ COVERED WITH / INV E~r~ - o~g= , T, INV, = 95,85 NIN. DF 8 INCHES DF 3RAINRDCK, BOTTDM / ' ~' - ~'~d OF BOX TO BUTTON DF BLOCK PEA IS / , , APPROX. 15 INCHES, ~~ 1,85 INCH PVC PRESSURE LIN~ NOTE, THE UPFLOW CHAMBER IS INSULATED WITH 8 INCHES FROM STEP TANK. CHECK VALVE THE LINE IS BURIED 4 FEET BEEP DF SPRAYED URETHANE, BY ANCHORAGE TANK, IN STEP TANK PREVENTS BACK- · COVERED WITH INSULATION BOARD, FLOW TO TANK. GROUND COVER OVER TRENCH = 100.7 TD 101,0 MINIMUM COVER = 8,45 FEET. TDP~DIL ~ RESEEDING / FOR LOCATIDN DF N,T SEE PLAN DRAWING ~; '~', A, TRENCH LENGTH 30+ FEET LAYER BF LAKE BTIS C, ORIGINAL GRADE = 9~,4 GR~VEL, ~, ~QTTOH ~XCAVATION = 95,4 5,0 , TOTAL DEPTH = S FEET TB ~OTT~ ~F SAND ~ ~~ E, TOP ~K SAND = 9%4 F. INVERT OF DRAINPIPE = 97.9 SEPTIC UPGRADE, L~T I, PARK PLACE S/~, ~'~,~r~/t~ .... ........ /O;~x~'. J C~-7953 ." ALASKA ~ATER & ~ASTE~ATER ~h:~ '..... . ...._~ DATE: 12/4/97 DWN, GARNESS SCALE, NTS P?t-ltTM brand fax tmnsmi?_._el memo 76/~ · i : MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PERMIT NUMBER:SW970400 DESIGN ENGINEER:ALASKA WATER & WASTEWATER SERVICES OWNER NAME:~T~ FRED MARTIN OWNER ADDRESS:16411 ST JAMES CIR ANCHORAGE, AK 99516 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT DATE ISSUED:il/19/97 EXPIRATION DATE:il/19/98 PARCEL ID:02009247 LEGAL'DESCRIPTION: PARK PLACE LT 1 LOT SIZE: 43401 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80}. 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: THIS PERMIT IS ISSUED FOR THE CONSTRUCTION OF AN INNOVATIVE RECURCULATING TRICKLING UPFLOW SYSTEM. AS A CONDITION OF THIS PERMIT, THE OWNER SHALL MAKE ARRANGEMENTS FORTHE SYSTEM TO BE SAMPLED A MAXIMUM OF ONCE A MONTH FOR 12 MONTHS AFTER Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Dear Homeowner/Prospective Buyer: The on-site wastewater disposal system you are purchasing/installing is an "alternative" wastewater disposal system. This system, known as a "Recirculating/Upflow Filter Septic System", is undergoing testing within the Municipality of Anchorage under the Alternative System section of the Wastewater Disposal Regulations (AMC 15.65). There are certain risks involved with the ownership of one of these systems: 1. The technology used in this system has been shown to be effective in other areas. The system is currently undergoing a two year testing period in Anchorage under the guidance of the Department of Health and Human Services (DHHS) and the State of Alaska Department of Environmental Conservation (ADEC) to determine its effectiveness in a subarctic environment. 2. Changes to the Wastewater Disposal Regulations (AMC 15.65) through Mtmicipal Assembly action will be necessary prior to this system being approved as a standard system. 3. The system for this property received a vertical separation distance waiver from both State of Alaska and Anchorage Municipal Codes to ground water. This waiver was granted due to the system's expected performance within the site conditions on this property. I (we) certify that I (we) have read the above statements and am (are) aware of the risks outlined. I (we) also certify that I (we) am (are) in the process of purchasing (property legal description): ~,Purchaser Name) ,,/ O (Purchaser Name) - (~urchas~i~re) ~ ~ - ~h~a~re) Notarize Here State of Alaska On this 19th day of November, 1997 Nancy Klingenmeyer personally appeared before me whose identity i proved on the basis of V ~otary Public My commission expires 7320 East Chester Heights Circle - Anchorage - Alaska 9950'~'WIRONMENTAL ~E~VlCES Phone (907) 33%6179 ~ Fax (907) 338-3246 NOV 0 7 1991 Consulting Engineers RECEIVED November 6, 1997 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref.' Septic System Upgrade for Lot 1, Park Place S/D. RECIRCULATING UPFLOW FII,TER (RUF) SYSTEM To whom it may concern: 1. GENERAL: The existing 3 bedroom home is served by a private well and septic system. The drainfield is surcharged and must be upgraded at this thne. Given the location of the structure, the old bed, the protective well radius', the area available for the new septic system is very limited. Test holes to the east of the existing bed, and near the driveway (TH #2 & #3) revealed unsuitable conditions for an onsite septic system. It appears that a portion of this area was used in the pas~ for burying stumps, wood, organics, eot. The area to the northwest of the bed was ruled · out because of the amount of trapped (ponded water) in the drainage ditch (east side of St. James Circle), Based upon the information we have at this time, the only suitable site appears to be near the southwest portion of the lot (TH #1). Attached is a copy of the soils logs. Because of the space constraints, and the soil/groundwater conditions, we are proposing to install a Recirculating Upflow Filter (RUF) system, designed by Orenco Systems, Inc., and marketed by Anchorage Tank. There is a drainage ditch, and a culvert under the road, immediately downhill from the proposed trench site. On 10/8/97 there was no running water in the ditch. On 11/6/97 there was water running in the ditch, and daylighting from the culvert on the other side of the road. On 11/5/97 a "chinook" Wind, accompanied with rain, resulted in extremely wet conditions. It is reasonable to assume that this ditch will have water in it during spring break-up, and during/after ."significant" rainfall events: The new trench will be roughly the same distance from the ditch as the existing bed system is. Does DHHS have any historical data on this ditch, and has it ever been defined as a surface water? IfDHHS defines this as a surface water, the only other possible sit6 would be to the east of the driveway, and between the protective well radius' for Lots 1 & 2. The useable area at this location is very limited also. Given that fact that we found suitable soils in TH #1, we would prefer to install the system in that vicinity. Please provide direction from your department. The specifics regarding the design are summarized as follows: 2. SOIL CONDITIONS (TH #1): A test hole was dug to a depth of 9 feet. Below a depth of approximately 5 feet, the soil appeared to be tight, wet, silt. At a depth of 3-4 feet, the soil perked at 15 minutes per inch. On 10/16/97 groundwater was encountered at a depth of 5 feet below grade. 3. DllABIFIELD: The intent is to install a Recirculating Upflow Filter (RUF) system that will allow the use ora small drainfield in the area of the TH. The size of the drainfield will be based upon the previously established criteria for the RUF systems, which dictates that soils percolating between 1 & 30 minutes per inch have an allowable application rate of 4 gpd/fi2. Given this at2plication rate, the system (3 bedroom house, 450 gpd) will require a dralnfield area of 112.5 ft~. This corresponds to a 5 foot wide trench that is 22.5 feet long. To be conservative, we are going to install a 5 foot wide trench that is 30 feet long (150 fi2). 4. ORENCO PACKAGE SYSTEM: The STEP tank with the trickling and upflow filters will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. Since you are familiar with the operation of the system I won't elaborate. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 5. SURFACE WATER: See comments in paragraph one regarding the drainage ditch. 6. TOPOGRAPltY: The entire tot slopes gently downhill (approximately 4%), to the west, and southwest. The slope transitions to a 20% slope about 25 feet below test hole #1. Fifty-two feet downhill from the test hole, there is a steep (100% slope) cutbank. We will place the new trench so as to maintain a 50 foot separation to the cutbank. 7. CLOSING: Clearly, this property has numerous site restrictions which limit the potential for septic system upgrades. The suitability of this design will be limited by the soil/groundwater conditions at the proposed trench site. It is my recommendation that the contractor install the trench, prior to purchasing and installing the RUF system components. In short, they should ensure that the drainfield can be installed prior to committing to the complete installation. I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call me a 33%6179, or 244-9612. / Sincerely,~ A ~, / PfindiI~al u arness, P.E., M.S. 16~-TH AVENUE LOT 11~ PARK PLACE S/I), ~ w o | THAN 100 FEET FROM THE ~ . \ SEF~TIC gYSTEM X OF ~DUND SYSTEM LilT 10, PARK PLACE PVT, ~ELL AN~ ~EPTIC S~STEN. ~L ~ "~. ~ YELL k/ M"'--t.: " / ~H~ V~UVU~ UVb~~~ S/~, PVT. WELL / / '/ SEPTIC SYSTEM, ~. OF A~ ~ SEPTIC UPGRADE, LUT 1, PARK PLACE S/3 ~F-.7,7~i7.-~ ............... PREPARE3 FBR: FRE~ NARTIN PREPARE9 3Y, ALASKA WATER ~ ~ASTE~ATER , DATE~ 1~/4/97 ORAWN, GARNESS SCALE, 1' = 100' / '~, '~ \ ~/~H PER ~UaT MINIMUM, ~ ~ ~ ~B FEET BY 58 FEET. / ~ ', ~ ~ . / ~ ~ ULATIN6 TRICKLING FILi'ER, t ~ % % / ~ / ~ PER ANEH~TANK DESIGN ~ k ~ % PER ANCH TANK~ ~/ ~ '~ES ~ ~IS AREA ~ ~SIGN ~ ~ED ORG~ FILL ~ / FTM o -. ~LL '. PREPARE]] FOR: FRED HARTIN DATE, 11/4/97 DRAWN, GARNEgS SCALE: 1' = 30' FEET NIN OF ANCHflRAGE ~/ITH RECIRCULATING TRICKLING FROM HOUSE, FILTER. PER ANCHORAGE TANK DESIGN. R B SET TANK LEVEL , I M APPROX. i5 INCHES. 1.25 INCH PVC PRESSURE LINE FROM STEP TANK, CHECK VALVE NDTE~ THE UPFLDk¢ CHAMBER SHALL DE INSULATED ~AITH 8" IN STEP TANK PREVENTS BACK- DF SPRAYED URETHANE, 3Y ANCHORAGE TANK. FLDV TD TANK. MIN BURIAL DEPTH DF 4 FEET, AND 4 INCHES OF INSULA- TION BOARD (2 FEET VIDE) OVER THE TOP DF THE PIPE, FOR EFFECTIVE ~URIAL DEPTH OF B FEET. TOPSOIL AND RESEEDING TD BE THE RESPONSIBILITY OF THE HDNEOVNER  FOR LOCATION OF M.T SEE PLAN DRA~ING 4 INCH PVC, 6 INCHES DF DRAINRDCK BELDV PIPE, / ~ FILTER FABRIC OVER DRAINRD~K / AND 8 INCHES DF INSULATION, ~'t~'5:~z~'~ A. TRENCH LENGTH : 30 FEET · ~ B. TOTAL ABSORPTION AREA = 150+ SQ. FT, 5,0 EXCAVATE TO DEPTH DF 3 FEET AND FILL BACK UP TO ~ITHIN 1 FOOT DF ORIGINAL GRADE ~ITH LAKE OTIS GRAVEL. THIS ~ILL ENSURE A 4' SEPARATION TO IMPERMABLE SOILS, ALASKA ~ATER & ~ASTE~ATER ~ro fesslO~' DATE: 11/4/97 D~N' GARNESS SCALE~ NTS Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 2 3 4 7 8 ~0 12 ~3 14 17 15 20 DATE PERFORMED Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? SITE PLAN ~ ¢:..~,,q~.~ / s ATW.AT DEPTH? Deplh to Water After 5" Monitoring? Date: ] Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE /~" (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~/~_~_0 FT AND 4o_~__~O FT ~ ~ i ~[~ T~IS~ST WAS PERFORMED 72-008 (Rev, 4/85) PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17- 18- 19- 20 COMMENTS Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST DATE PERFORME~ ~' ~/~ownship, Range, Section: ~ ~" SLOPE SITE PLAN WAS GROUND WATER ~____~ ENCOUNTERED? , IF YES, AT WHAT O DEPTH? ~ p E Deplh t0 Water Alter ~0~it0ring? Date: Reading Date Gross Net Depth to Net Time Time Water Dropsy. TEST RUN BETWEEN tminutes/inch) PERC HOLE DIAMETER __ FT AND __. FT ~-~ C ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: II/,~.../C/.¢/- 72-008 (Rev. 4/85) PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG m PERCOLATION TEST LEGAL DESCRIPTION: [.~O"~ t .) I~,...~--~ p[.,A~-..,~ 1 2 3 4 ,5 6 7 8 9 10 11 12 13- 14- 15 16 17 18 19 20 COMMENTS t,d ["& S t~. t ~--'~-.~ t ~. SITE PLAN DATE PERFOI~I~" Township, Range, Section: I I SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Oepth Io Water After Moniloring? Date: Reading Date Gross Net Depth to Time Time Water / Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER __ TEST RUN BETWEEN FT AND __ FT PERFORMED e,: , OERT,F, THATTH,STSTfASPERPORMEO,N ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) WATERWELL - TEST PUMP REPORT Owner~ ~ ~ Address I(~'l I Well Location ~ ~ ~ ~.~ Well Information: Tfl. Depth ,~0 _Depth of Casing Z~'"7' Screen From To Casing Size __.Screen Dlam I,,~/',~ Screen Slot Remarks Pump Information: Pump On: Intake Depth ~0~ Pump Size Static Water Level -~-~1,/~r'-J Av. Discharge Time /..,-2:/~__'~ ~o rT~. Date ~/~{~/Q'7 Pump Off: '7,4 Air Line Depth ~L.~_.CT'~O~J ~C_... GPM. Max. Drawdown Time 1: 4D prT'l Date WATER PIEZO- FLOW WATER PIEZO- FLOW TIME LEVEL TUBE GPM REMARKS TIME LEVEL TUBE GPM REMARKS IAoO 0 0 i~'.b~ ~.'~ ~ I I I ~ i i ' ~ ~ ] I ~ i i ! ........ ~ ........ . _ ~ ..... _~,.../ MUNICIPALITY OF ANCHORAGE . ,.. ~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME /. P /~/~ , ~ ~, . (~)~ PHONE ' ~NEW MAILING ADDR ESS~ O -07 7 LEGAL DESCRIPTION LOCAT/O~ ~ ¢~ ~ W~.~, Absorption area Dwelling PERMIT NO. ~D~ Manufacturer ~ M~~ No. of~partments Liq. ~a~ty in gallons Inside length Width Liquid depth ~ -- ~ Material ~city in gallons D We]l Foundation ~ Nearest lot line PERMIT NO, ~ ~ DISTANCE TO: ~ ~0 ~/O ~ ~~ Z No/of~ lines Length~¢of each~line Total length of lines ' Tr~c~width~ Distance between lin~ ~= Topoftieto inis grade z Material beneath tile ...... ~ ~ ~ ~ (.~ Total effective absorption area Length Width Depth PERMIT NO. ~ ~earest lot line ~ ~ ~~ Depth Briller Distance to lot line P[BUlI ~0. ~ DISTANCE TO: Building foundation Sewer line Septic 'tank Absorption area(s} OTHER PIPE ~TERIALS SOl L TEST RATING~ / ~ APPROVED ~ , DATE LEGAL 72-013 (Re{ ~ ':'~.'-' .~ -' ...... --"~ ,- ~, /- PERMIT NO. ,: ::~FlP~5~: b ~ : ' RPF'LICRNT TRENT 5LR'T'MRKER PO BO:, 50-0787 TYPE OF SOIL RE:SC~RF'TION S,:,TEM IS: MR;~IMIIM NLIMBER OF E,E[.RUUM_, = ~ SOIL RRTING THE RE~;~UIRED SIZE OF THE SOIL RBSORPTION S'T'STEM IS: [:,EF"TH= 6. 5 LE[-~G1-H: :..1.. :E: ~Z.l G F~ R'-..' E L [:.E F'TH: THE LENGTH DIMENqIFIN IS THE LENGTH ,'IN FEET) OF THE TF. EN_,H ... DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE GROUND RND 'THE BOTTOM OF THE E~(CRVRTION (IN FEET:.". THERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETNEEN THE OUTFFILL PIPE ~'FtND THE BOTTOM OF THE EXCRVRTION ,.'.IN FEET). 5 F-:E _F--~LI TREE-'" SEPT T C: TI-3~'-.~-=:: S PERMIT RPPLICRNT HRS THE RESPONSIBILITY TO INFORM TFIIS DEPRRTMENT DURING THE INSTRLLRTION INSPECTIONS OF RNY WELLS RDJRCENT TO 'THIS PROPERTY RND THE NUMBER OF RESIDENCES THRT THE HELL WILL SERVE. -r~,:, (2) ~ ~SPEC:TI C,P-~S R~:E RE~:!fJIRE[:~ BRCKFILLING OF RNY SYSTEM WITHOUT FINRL INSPECTION RND RPPROVRL BY THIS DEPRRTMENT WILL BE SUBJECT 'TO PROSECUTION. MINIMUM DISTBNCE BETWEEN R WELL RND RN'~' ON-SITE SEWRGE DISPOSRL SYSTEM IS ±00 FEET FOR 8 PRIV8TE HELL OR t50 TO 20~ FEET FROM H PUBLIC HELL DEPENDING UPON THE TYPE OF PUBLIC HELL. MINIMUM DISTBNCE FROM 8 PRIVATE WELL TO 8 PRIV8TE SEWER LINE IS 25 FEET 8ND TO ~ COMMUNITY SEWER LINE IS F5 FEET. HELL LOGS 8RE REQUIRED 8ND MUST BE RETURNED TO THE DEP8RTMENT WITHIN Z~O D8YS OF THE WELL COMPLETION. OTHER REQUIREMENTS MRY RPPLY. SPECIFICRTIONS RND CONSTRUmZ:TION DIRG~RE RVRILRBLE TI] INClLIRE F'ROF'ER INSTRLLRTION. - - - . F'EF:~'] ~ I E:~.F" ~ RES ~ CERTIFY THRT · : ~ RN FRN~L~RR I.,J~TH THE REQUIREMENTS FOR ON-SZTE SEWERS fiND WELLS RS SET KOR'~H BY' THE MUN~C~PRL~TY OF RNCHORRGE. 2: ~ H~LL ~NSTRLL THE S'~'STEM ~N RCCORDRNCE H]TH THE CODES. ]:: ~ LINE:,ERSTRND THRT THE ON-S~TE :,EHEE. ~T_,TEM MR~ REQ_~RE ENL~RG~HE. NT ~F THE : I bNED :LRYMRKER PERFORMED FOR: LEGAL DESCRIPTION: 2 3 5- 6- 7 8 9 10 12 13 14 15 16 17 18 19 20 COMMENTS MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99502 276-222~ SOILS LOG- PERCOLATION TEST [] SOILS LOG PERCOLATION TEST DATE P..FOmED: / SLOPE SITE PLAN ~--H-H---i---, WAS GROUND WATER ENCOUNTERED? y~' IF YES, AT WHAT DEPTR? /o~ ~. Gross Net Depth to Net Reading Date Time Time Water Drop / ~ od~o ,~."/~; o I; ~" o PERCOLATION RATE Z O (minutes/inch) TEST RUN BETWEEN 5'/'~-- FT AND ? /~- FT 72-008 (7/76) DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # ~) ?-'~ - O~'Z-- 1. 'GENERAL INFORMATION Complete legal description Mailing address " Lending agency ~ Mailing address Day phOne ,--"" Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: ~ ~ TYPE OF WATER SUPPLY: Individual well ~ Community well Public water NOTE: lng to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site ~ Holding tank Community on-site Public sewer If community well system, provide written confirmation from State ADEC attest- NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 {Rev. 1/91) Front MOA~I 5. STATEMENT OF INSPECTION BY ENGINEER. As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Alaska Water & Waste cater Phone Date Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments ' r .' Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-O25(Rev, 1/91) Back MOA#21 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825 L Street, Room 502° Anchorage, Alaska 99501. (907) 343-~7~ Legal Description: b- o-~- ID Health Authority Approval Checklist <: JP' Parcel I.D.: A. WELL DATA Well type Log present (Y/N) Total depth Sanitary seal (Y/N) Date of test Static water level Well production IfA, B, or C, attach ADEC letter. ADEC water system number Date completed '~ Cased to FROM WELL LOG WATER SAMPLE RESULTS: Coliform Date ;, ;;mp,e: B. SEPTIC/HOLDING TANK DATA Date installed /! /c/cF Foundation cleanout (Y/N) Date of Pumping Casing height (above ground) Wires properly protected (Y/N) AT INSPECTION Collected by: "~'~ L~L'c4~'~t~ g.p.m, g.p.m. Nitrate . ~"Z,~ w'~d~ Other bacteria Tanksize '2,OOO Number of Compar/ments ~ Cleanouts (Y/N) Depression (Y/N) /,,/'O High water alarm (Y/N) Pumper /'"//~ C. ABSORPTION FIELD DATA Date installed ! Length BO * Width Soil rating (g.p.d./fF orJ~ ! "' Gravel thickness below pipe System type Total depth Effective absorption area l ~D +' Monitoring Tube present (Y/N) ~ Depression over field (Y/N) __ ~Date~test. Results (Pass/Fail) For Fluid depth in abs~ gal. water added (in.): Fluid depth (ins) Minutes later: Absorption rate ~ g.p.d. peroxide treatment (past 12 months) (Y/N) bedrooms If yes, give date 72-026 (Rev. 3/96)* Date installed II Manhole/Access (Y/N) High water alarm level at* Cycles tested /,4/~ Size in gallons "Pump on" level at* ~ T'I~ ~-.P__ "Pump off" level at* '~ *Datum ~,. ~ o/'"~ O~ E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot /~00 ¢' Absorption field on lot /OD ~ Public sewer main /~///4 Sewer/septic service line c~o ~ / On adjacent lots On adjacent lots ! OD/"'r' Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: ! Foundation I 0 4' Property line ~_.~ /4- - - Absorption field ~ ~ Water main/service line /0/*' Surface water/drainage /00 (-/- Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~ /+ Building foundation ~'~0 ! Surface water Curtain drain Water main/service line /0 /4. Driveway, parking/vehicle storage area 20/4. Wells on adjacent lots /0~0/~. ENGINEER'S CERTIFICATION I certify that I have detercpilCed ¢1~ ~ld inspections and review of Municipal in conformance~Ml~//~/~k,lines in effect on this da te . SignatUre "~-//'-~./~- k,~ ~-' - Engineer's Name Date HAA Fee $ 'F Date of Payment Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number .~ CT&E Environmental Servi=es Inc. CT&E gef.# Client Name Pro,~e~t Name/// Cilcnt 5ample ID Matrix Ordered By 977284001 AK Water & Wastewaler Lot 1, Park Place Lot 1, Pa~k Place $/D Drinking Wa~er 0 Coliform 0.4Z~ 0.00 Client PO// Priz~t~d Date/Time 12/02197 19:41 CollectedDate/Time 11/26/97 10:25 Received Date/Time 11/26/97 16:00 Technical Dlr~c$or: ~ephen C. Edt Method ~PA 300.0 Prep once Oete ]n{t 10 max 11t~6/97 RMV DATE DATE DATE INSPECTO~ INSPECTOR MUNICIPALITY OF ANCHORAGE  D~PART~ENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - ~nchorage, ~laska ENVIRONMENTAL SANITATION DIV~~ ~BL '~ Telephone 264-4720 ~ ~?~- ~,:~b.~ REQUEST FOR APPROVAL OF INDIVIDUAL WAT~ AND $~ER~ILITIES 1. PROPERTY OWNER ~¢~" [ PHONE MAILING ADDRESS PROPERTY RESIDENT (If different from above) PRONE 2. BUYER PHONE MAILING ADDRESS 3, '[E~DING I~$TITUTION PHONE MAILING ADDRESS 4.-- ~ ----REALTOR/AGENT I PHONE I MAILING ADDRESS 5. LEGAL DESCRIPTION STREET LOCATION / 6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS [] One [] Four ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY ~ Three [] Six [] Other 7. WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well tog is required for ail wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Icg if available.) 8. SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** /~'/' YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. e/79) : THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE I~ FiVE [~ OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INBTALLED []PUBLIC UTILITY Connection Verified INSTALLER [~]Septic Tank or [] Holding Tank '~ ~.. ~ Size: t.,~'~ IfTank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES Septic/Holding Tank Absorption A[ea Sewer Line I Nearest Lot Lih~ 1 WELL TQ: Absorption Area to nearest Lot Line 5, COMMENTS ~PPROVED FOR '- ~,~ DROOMS ~ONDITIONAL APPROVAL (letter mF~ accompany certificate) 72-010 (Rev. 6/79) t 82.5 "L" STREET ANCHOR/-',G L (907) 264-4111 GEORGE M. SULLiVAN, MAYOR DEPARTM[:N'.r OF ,q£!ALTH AMD ENVISONMEN'rAL March ll, 1981 Raymond T. Slaymaker Post office ]3ox 10-.787 Anchorage ~ Alaska 993__1 Subject: Lot 1 Block I Park Place Subdivision Approval for your individual sewer and water facilities cannot be granted until the following items have been completed: 1) The water analysis report needs .to be delivered to this office from the Chem Lab~ 5633 B Street, for our review~ 2) The depression or p~.,~, around the well casing needs to oe :filled with impervious type soil so that it slopes away from the well casing. 3) Exposed electrical wires to the well head are z., violation of the Municipality of Anchorage codes and must be encased in conduit 'and buried. Please notify this office for a reinspection when -the noted descrepanc, ies have been corrected. If there are any further questions, --'~¢~a call this office at 264-4'720 N.~. c:. se · eincerely Robert C. Pratt~ R~S. Associate ~ ''~' '· opec 1. ~. ]. 1_ .~ ~ RcP/~jw cc: Alaska Mutual Savings Bank 1503 West: 31 Avenue 99503