Loading...
HomeMy WebLinkAboutPAULSON Lots 65A & 65B S-7102 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION Environmental Health Division CASE REVIEW WORKSHEET CASE NUMBER: DATE RECEIVED: S-7102 June 2, SUBDIVISION OR PROJECT TITLE: Lo%s 65A, 65B Paulson Subdivision 1983 COMMENTS DUE BY: June 17, 1983 ( ) PUBLIC WATER AVAILABLE ( ) PUBLIC SEWER AVAILABLE ( ) COMMUNITY WATER AVAILABLE COMMENTS: 71-014 (Rev, 5/83) ALASKA er'''IROFlm~FITAL COFITROL ~nqin~rir, q 8 I~nuironmcnlol $~udi~s StUn' I Ct~S, IPIC.. IVAN PAULS ON SRA BOX 477-X ANCHORAGE ~. 99507 MAY 9 1983 STATEMENT SBDN T12N R3W SECTION 33 SELLER- IVAN PAULSON BLOCK BUYER- LOT SEPTIC TANK PUMPING WELL FLOW TEST ADEQUACY TEST WATER CHARGE 60.00 175.00 235.00 0.00 $470.00 IF DESIRED PAYMENT MAY BE DEFFERED TO CLOSING AND MAY BE PAID FROM THE ESCROW ACCOUNT. PLEASE LET US KNOW. ~ THANK YOU ~~ 12oo LUcsl 33r~1 Aucnu¢, Sui,¢ B · Anchoroqc AIo.*~Q 99503 ,, (907) 276-1361 ALASKA 6 ']IBO F EF IAL COBTBOL $6 'JICES, IF C.. gnqlr, ecrlnq ~, ~nuironmcnlaJ Sludies May 24, 1983 Ivan Paulson SRA Box 477-X Anchorage, Alaska 99507 Subject: Well Flow Test on T12N R3W Section 33 Lot Dear Mr. Paulson: A well flow.test was performed on the above lot on May 9, 1983. The test was p~rformed simultanously with the adequacy test of the on-site septic system. The static water level was measured at 92.15 feet prior to testing. The test was conducted Over a 4 hour and 22 minute period. The pump maintained an average of 3.1 gallons per minute for 3 hours and 35 minutes. The maximum measured level of drawdown was 127.6 .feet. The well maintained a water level of approximately 126.5 feet, after 75 minutes, throughout the pumping phase of the test. The well had recovered to static water level (92.15 feet) withing one hour after pump usage was noted. Since no well information (depth, pump level, et=c) was available precise calculations on drawdown and recovary can not be performed. The Well did produce a flow<rate of 3.1 gallons/minutes (average) over a period of time in excess of 3 hours. The well also "recovered" the static water level within one hour. From this information, and the well-performance during the test, it appear.s to be adequate for the 3 bedroom residence on the lot. If this office can be or any further help you can contact me at 276-1361. Approved: .. . ..... ' .: Le~/C~. ~eid Oj~':, PhD, PE president Sincerely, /Larry Montgomery 1200 UJesl 33rd Aucnuc. Suile B · Anchoraq¢. AJasko 9%03 · [907) 276-1361 ALASKA c ,jll orlmsrlTRl. COFITI OL Sf'"UI SS, IriS... ~n§incmn§ 8 I~nuironmcnld MAY 9 1983 IVAN PAULSON SRA BOX 477-X ANCHORAGE AK 99507 SELLER - IVAN.PAULSON BUYER- % SUBDIVISION-T12N R3W SECTION 33 BLOCK- LOT-. . ~' ADEQUACY TEST FOR SEWER SYSTEM THE TYPE OF ABSORPTION SYSTEM IS A SEEPAGE PIT WITH~AN UNKNOWN AREA. THE SYSTEM IS CAPABLE OF ACCEPTING 450 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 675 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A 3 BEDROOM HOME. THE SEPTIC TANK WAS PUMPED ON 4/29/83 . SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUM~ OF THIS 3 BEDROOM HOUSE. 1250 IS ADEQUATE FOR 1~00 Ylrsl 33rcJ Aucnu¢. Suil¢ [~ · AncJ~orocl~. hlosLo 99503 · [907] 276-1361 ALASKA IIBOIIIll D AL CO[ BOL Subdivision ~ec Supplemental Soils Information. ~ TI~V r~JBlock '- TH I 1 2 3 4 5 '7 8 9 '10 11 13 14 15 16 17. 18 19 20 LOI ~ LO'[ .TH Z TH ~ 10 11 17 718 19 20 1 2 3 4' 6 7 10 11 12 13 16 17 18 20 LO1' 1 2. 3 '4 ' 5 11 12 .i3 .14 '~2oo LUgs, 33.1 R,,,,~. Sum 13 · A,cho~o¥. ,Rloskn 995,03 · (907) 276-1361 UNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L Street, An&horage, Alaska 99501 264~,720 SOILS LOG - PERCOLATION TEST ·PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: DATE PERFORMED: SLOPE SITE PLAN 'AzlSs 1 2 3 4 10 · 13 14 2O COMMENTS So PERFORMED BY: WAS GROUNDWATER· ~ ~-S t IF YES, AT WHAT DEPTH? : Gross Net Depth to Net Reading Date Time Time Water Drop · 8'~- - .5o -  ' .q'o~ 2o . zq · l I · ''.. .: q~8 Zo ,Zq ,Iq y C. 'Reid, Jr. ~ ~q -- · q e - . ~ ~ ~l~ (minutes/inch) '*' PERCO~TION RATE TEST RUN BE~EEN ~ FT AND ~ U~ FT Tut 6 "~j,,:¥r.r i,-',. CERTIFIED BY: DATE: 72-008 (6/79) /&LAbl'tP, Ir I~IVIKUI~IMi:-I'~ i/~L CONTROL SERVICE, INC. Engineering & Environmental S ies -t2-2~~venue Suite 13 -'?'~)(~ ANCHORAGE, ALASKA 99503 , 'J,_,.., ;, ,.-/ ~-- (907) 276-1361 TO: IVAN PAULSON SRA BOX 477-X ANCHORAGE ALASKA 99507 SHIP TO IVAN PAULSON SRA BOX 477-X ANCHORAGE ALASKA 99507 IDATE OF INVOICE 5/23/83;' ACCOUNT NO. 83261 :~UANTITY SER PLE THA} ORIGINAL DATE SHIPPED .pASH LEGAL:T12N R3W SECTION 33 LOT 1,_6 ~ BACKHOE SERVICES' LARRY CALL VISUAL SOILS LOG PERCOLATION TEST yOU ,R.oR~iER NUMBER :ipNiT RRICE 100.00 150.00 80.00 ICE CHARGE @ 1.5% PER MONTH AFTER 30 DAYS 'NUMBER ON ~SE RETURN COPY OF INVOICE WITH PAYMENT OR P'UT ACCOUN K YOU FOR THE ASSISTANCE IN KEEPING OUR RECORDS CORRMCTToTAII , AMOUNT 100.00 150.00 80.00 CHECK. "jJ O~J . UU 3-.-30,00