HomeMy WebLinkAboutROCKHILL BLK 2 LT 17 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: _OSP251298 PID Number: 015-362-29 Dwelling: RN Single Family (SF) 171 with ADU [I Duplex (D) R Two Single Family Project: [:1 New OR Upgrade Name ASPEN GROVE TRUST C/O ARM SEPTIC SERVICES A ORPTION FIELD El D Trench El Wide Trench R Bed Zound Site Address 6460 LIMESTONE CIRCLE, ANCHORAGE, AK Other Z Phone Number of Bedrooms Soil Rating�ISF depth grade 907-688-9433 4 ITotai Ft. LEGAL DESCRIPTION Depth to pipe invert from I origigal'S-de -rr' , ­ EXISTING 401 el depth beneath pipe Subdivision Block Lot ROCKHILL 2 17 Ft. Fill added above originalI length Ft. !n Ft. Township Range Section Gravel width �� Ft. Beds: Number of Lines Di Ines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total rption area Number of trenches Dist, between ches From Tank Field Tank Line Ft2 - Well 100'+ EXIST. - - 25'+ TANK 9 Septic 0 S.T.E.P. 171 Holding 0 Other Manufacturer GREER TANK Capacity *1500 Gal. Surface Water 100'+ EXIST. - - Material Number of compartments Lot Line 5'+ EXIST. - - NA PLASTIC 2 Foundation 10'+ EXIST. - - LATION I Manufacturer Remarks *TANK IS LARGER THAN REQUIRED. Gal. Alar:�Ioc:>fion�E 1e cy " 7 r tailed 1 4"� Installer PIPE MATERIAL House totank D3034Tank to D3034 drainfield ARM SEPTIC SERVICES Drainfield EXISTING COIMTD3034 Inspector GARNESS ENGINEERING GROUP, LTD. BENCHMARK (Assumed elevation) 100.00 It Inspdates: ection Is, 11/6/2025 Location and description 2 nd 3'd 4"' BOTTOM OF SIDING NEAR FCO ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineers Stamp optSSooQdOOF Conditional Approval: Date T 7 ....... ... .. .. ..... ........ Septic Syste ey Go ess I Approved Date 9. CE -79 3 T ta -IS' e: this approval does not include well permit requirements Pr ofessi-l'o' #aeCC884 kr%qzv V;;1UzJ 71 PERMIT NUMBER: OSP251298 RECORD DRAWING PARCEL ID NUMBER: 015-362-29 A B !•• ' ••' • / FCO 55.1 12.0 \ :� _ . •' 'DRIVEWAY •;' , MH1 56.4 51.1 ••..:: ..:'..; ST1 59.7 55.0 •`� ' ' , :, f„ •. !'•• DBL1 62.2 57.8 �' ' -. DBL2 62.9 58.5 , I / \ •• . ' . ��' NOTE: PIPE LOCATIONS ARE \ I / SHOWN PER GEG SHOTS TAKEN WITH LEICA DISTO /i S910 LASER DISTANCE METER. SWING -TIES TO HOUSE CORNERS WERE GENERATED IN AUTOCAD. $ EXISTING 4BEDROOM / m HOUSE NOTE: PER THE CONTRACTOR, THE OLD NEW 1500 -GALLON SEPTIC TANK WAS DECOMMISSIONED o GREER PLASTIC PER UPC AND DISPOSED OFFSITE. C SEPTIC TANK U)\ B /, \ DOUBLE CLEANOUTS (DBL1 & DBL2) EXISTING DRAINFIELD G I APPROXIMATE LOCATION OF DRAINAGE OPEN CHANNEL O MAPPING. R NG. NO WATER OBSERVED S R ED WITHIN 100• • FEET OF DRAINFIELD ON 9/22/2025 AND ON 11/13/2025 l /. 10' TELE. & ELEC. ESM'T. OF 9 Ltd /u..uu.n m ■ uuuu■Suw� ENGINEERING «, SALES - CONSULTING 3701 EAST TUDOR ROAD SUITE 101 -ANCHORAGE, ALASKA • PHONE (907) 337-8179 • WEBSITE. www.gamessengineenng eom •••a. ■ •■..•••■.■. ............mo PREPARED FOR: PHONE NUMBER: PAGE NUMBER: '; J Ga eS5 �' 4/t C/O ARM SEPTIC SERVICES 907-382-0333 2 OF 3 �j�� C -79537;�• AV Air PROJECT/LEGAL DESCRIPTION: DRAWN BY:•'••••••••� ROCKHILL; BLOCK 2, LOT 17 J.L.M. 1� FQ p'•• ••.�••• P�, ��► TYPE OF WORK: DATE:LIC NSE ♦r1,S`;; `►�� RECORD DRAWING OF SEPTIC TANK UPGRADE 11/13/2025 #AECC884 P NUMBER: RECORD DRAWING V Y I N G PARCEL ID NUMBER: OSP2SP251298 015-362-29 TOP OF MANHOLE FINAL GRADE GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING 3701 EAST TUDOR ROAD SUITE 101 `ANCHORAGE, ALASKA -PHONE (907) 337-6179 ' WEBSITE: wm .gamessengineering.tom PREPARED FOR: HONE NUMBER: PAGE NUMBER: P C/O ARM SEPTIC SERVICES 907-382-0333 3 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: ROCKHILL; BLOCK 2, LOT 17 J.L.M. TYPE OF WORK: DATE: RECORD DRAWING OF SEPTIC TANK UPGRADE 11/11/2025 3@ 4 ®0"®gYAr �`®,®o ♦® .....A: . . ... .. ............. ®� rev t..� rness i m 0P �� E-7953 ° =d ♦��. l 1 �.1� Z� <c o lwoLICENSE MM®tFESSO� ��4 #AECC884 '® ®�'�* MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP251298 Work Type: Septic Renewal Tax Code Number: 01536229000 Site Legal Address: ROCKHILL BLK 2 LT 17 G:2438 Site Mailing Address: 6460 LIMESTONE CIR, Anchorage Owner: ASPEN GROVE TRUST Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 8/22/2025 8/22/2026 55386 ❑ Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: Issued to GEG Date: 8/22/2025 Date: 8/22/2025 4 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 015-362-29 Property owner(s) Jay and Kathy Rowe c/o ARM septic Mailing address 6460 Limestone Circle *Anchorage Site address same Legal description Rockhill B2 L17 Number of Bedrooms 4 Engineering Firm Garness Engineering Group Building Permit Number Day phone 907-688-9433 Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Disposal Field ❑ Initial ❑ Septic Tank ❑ Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: Of f Date of Payment: $/W24 Permit No. I,Y2V)w May 2025 Waiver Fees: Date of Payment: Waiver No. Distance: GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING August 14, 2025 Municipality of Anchorage Development Services Department On -Site Water & Wastewater 4700 Elmore Road Anchorage, AK 99507 Subject: Request for Re -issuance of Permit (OSP241119) to Replace the Septic Tank at Rockhill Subdivision, Block 2, Lot 17 To whom it may concern: A permit (OSP241119) to replace the septic tank on the subject property expired on 6/7/25. We are requesting that the permit be reissued so that the new tank can be installed. To the best of our knowledge, there has been no change in the site conditions that would invalidate the previously approved design. please contact me. I.S. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241119 Work Type: SepticTank Upgrade Tax Code Number: 01536229000 Site Legal Address: ROCKHILL BILK 2 LT 17 G:2438 Site Mailing Address: 6460 LIMESTONE CIR, Anchorage Owner: ASPEN GROVE TRUST Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 6/7/2024 6/7/2025 55386 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Reeeive"y: -fo Date: Issued By: Date: 1712- - ON-SITE SEPTICIWELL PERMIT APPLICATION Parcel I.D. 015-362-290, 4- KAY gowe' Property owner(s) C/O ARM SEPTIC ZVICES Day phone 907-688-9433 Mailing address 6460 LIMESTONE CIRCLE *ANCHORAGE, AK Site address 6460 LIMESTONE CIRCLE *ANCHORAGE, AK Legal description (Sub'd., Block & Lot) ROCKHILL; BLOCK 2, LOT 17 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field Fj Initial D Single Family (SF) (w/wo ADU) Septic Tank El Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: S Waiver Fees: Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. l P f Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit ApplicationAm Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241119, Deb Wockenfuss, 06/07/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241119, Deb Wockenfuss, 06/07/24 GE THAT PERTAINS TO THIS DES GN.ICATION BY PROCEEDING\ NERGEG, Ltd. HAS AN 8 PAGE LE17ERaL`DGAr/DN OF7oo ✓EI�RgDIUg FORWARD WITH THIS INSTALLATION, THE \ I ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE \ / READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. ' DRIVEWAY • •. r .. ..�:• �• • tib.: ? EXISTING 4 / z BEDROOM HOME V r 6r,CVLu,��, a'L, Llb -W E' p APPROXIMATE LOCATION OF EXISTING SEPTIC Y TANK; TO BE DECOMMISSIONED PER UPC _ CO (P\ \ \ DBL7 / MH1 .' APPROXIMATE LOCATION OF EXISTING DRAINFIELD / 9 PROPOSED 1500 GALLON HDPE GREER TANK /. GENERAL LOCATION OF "()'WELL RADIUS APPROXIMATE LOCATION OF DRAINAGE DITCH PER MOA WETLANDS MAPPING; PROPOSED DRAINFIELD IS 100'+ W ROCKHILL; BLOCK 2, LOT 18 N i--------- 10' TELE. 8 ELEC. ESM'T. 1" = 40' Aw �,.• �# GARNESS ENGINEERING GROUP, Ltd 4 ENGINEERING SALES CONSULTING =_ - 3701 EAST TUDOR ROAD SUITE 101 'ANCHORAGE, ALASKA • PHONE (907) 337-5179' WEBSITE: v~.gam ss gneef g.com. • • . ........................ PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ♦ (� :..Je ey arness r C/O ARM SEPTIC 907-382-0333 2 OF 2 �j ° C 7Q53 snAw PROJECT/LEGAL DESCRIPTION: DRAWN BY: !Val ♦�♦ �•• Z'd•.•'•c���'� ROCKHILL; BLOCK 2, LOT 17 D.J.G. 0� FOP • ..." �\P� �4W TYPE OF WORK: DATE: LICENSE ,4"SS\ �• DESIGN OF SEPTIC TANK UPGRADE 5/31/2024 #AECC884 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241119, Deb Wockenfuss, 06/07/24 k1 Z9 ,F0,Po 00 N 6 W w Q Ln u J U) En Of w O U O Z �d�oovppp Ofg�� o l7 r- 19 D Zw® s -j > Ln J : � CO Q oa s -i cn LLJ=m �oopOood� !L ~ > 0 H V) LL w 3 Q V) !_— 2 ® O Ln i— f: Q ®mZm t7 aa0 � �m<(m LL Z U E Q O Z LL LL U- Of LU UJ LU r JQ2J LL a-< F- L1 O pQ H V) LL a F— Ow H 2 > U !— > H 2 LU 4 O Q HtY Z Y j HVI�DQ QN 2LU J kDH- 0 ZZL/1ZLL® y� H W LL L7 N LL Z a � LL H Q o H3 ®OJI=-2 �O N LLof� U LU Y w Q o U hl O LL H LL = y, O Q� LL U L wa: J w n OmdHp Z rp LL F- = H V) LL Q wp HO lks ® Q>f=— �d�oovppp Ofg�� o 19 D 0� 0) J : � CO Q oa �oopOood� · Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site WasteWater Disposal System and/or Well Inspection Report Permit Number: SI,¢ 97OO¥8 PIDNumber: 01~.~ Name: 1~,~), ~ ~ Re ~ ~ Wastewater System: ~ New ~ Upgrade Address: 'Phone: 3~.~1~ ~No. of B~drooms: ~ Deep Trench ~ Shallow Trench ~Bed ~Mound ~Other LEGAL DESCRIPTION ~o~, Rating; Total Depth from origina~ grade: O, 8 GPD/Sq. Ft, Il, Lot: J 7 Block: ~~o~Subdiv~i°n:~t~ !Depth to pipe bo~om~, ~fr°m original grade: Ft Gravel depth~,beneath~ pipe Ft. Township: ~ Range: ~ Section: Fill added above original grade: Gravel length: I I, O Ft. ~ 3 Ft. WELL: ~ New ~ Upgrade Gravelwidth: Number of lines: Distance between lines: Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: ~.~ Date Drilled: Static Water Level: Installer: Date installed: Yield: ~ GPM;~ Pump Set at: Ft. Casing Height/~Above~ ~Gr°und:Ft. TANK SEPARATION DISTANCES ~Septic D Holding D S.T.E.P. TO Septic Absorption Lift Holding Public/Privat~ Manufacturer: Capacityin gallons: From Tank Field Station Tank Sewer Lines ~ O~ ~ ~ ~ Number of Compa~ments: Surface Water ~' >~' - - LIFT STATION LineL°t ~, ~ ~ ~ -- . Size in gallons:I~ Manufacturer: Foun~tionf~ ~, ~' -- - -- "Pump on" level at: "Pump off" level at:I~ High water alarm at: Cu~ain Pump Make & Model ~ Electrical Inspections pedormed by: Remarks: ~e~ /~tl~ ~t~ ~ BENCH MARK Location and Description: ENGINEER'~ 8EA~ ~o 72-O13 (Rev. 9/91) MOA 25 ., ;:: ,~ ,, PERMIT NO:SW970048 tPID NO: 01536229 PAGE 2 OF 3 LOT 17 BLOCK 2 LOt 18 (VACANT) SWING TIES: FROM:· TO: FDN. C.C. "D" 79.5' 142' S.T.C.C. "E" 115' 139' S.T.C.C. "F" 124' 144' DBL. C.C."G" 130' 147' TR. C.C. "H" 167' 209' TR. M.T. "1" 164' 197' TR. C.C. "J" 161' i68' TBM ..~LL WELL"A" L16,B2 HSE. ,R ,,' CORNER "B" 4 BDRM HOUSE 1250 GALLON SEPTIC TANK oUSE UNDER N LOT 16 BLOCK 2 SITE FOR SIMILAR ~/',,"~ REPLACEMENT TRENCH 53' (EFFECTIVE LENGTH) T' SOIL ABSORPTION TRENCH -- W. 8.3' GRAVEL BELOW PIPE 'H" LOT ~7, BLK. 2, ROCKHILL SlD SEPTIC SYST. INSTALLATION AS-BUILT PLAN VIEW FLATTOP TECHNICAL SERVICES SCALE: 1" = 30' 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 SEPT., 1997 PERMIT NO:SW970048 PAGE 3 OF 3 PID NO:01536229 4 SOIL 1250 GALLON SEPTIC TANK ,, INV. INV. ', 92.3' 92.0' ,, BOTTOM T.~ #1 ELEV. 75.0' ~ DRY 5~23/97 3' SOIL COVER PIPE INV. 90.8' (I 8.3' SEWER GRAVEl BOTTOM TRENCH EXCAVATION ELEVATION 82.5' 53' LONG SOIL ABSORPTION TRENCH LOT 17, BLK. 2, ROCKHILL SID SEPTIC SYST. INSTALLATION AS-BUILT PROFILE VIEW FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, ALASKA 99516 NOT TO SCALE DRAWN BY TFM SEPT., 1997 From : ~PI~ DRILL 987 J45 0~2 0¢t.20.1997 06:15 AM P02 STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING & WATER MGMT WATER WELL RECORD LOCATION OF WELL , . ,, , , [:iS DW LOCATIONfSKETCH= WELL OWNER: "~ f ~ ~ ~~-~ DEPTHS MEASURED FROM:C::]casing top Flground surface SOREHOLE DATA: Depth Mate¢ial Type and Color From To WELL DEPT)~: Depth of hole: ~ ft Depth of casing;'g-~"~ ft DATE OF COMPLETION .... / /7/ DEPTH TO STATIC WATER LEVEL: ~"/ ~' ft below ,;~ top of casing [:::} ground surface Date: ..~__.__1 /? / ~Z7 METHOD OF DRILLING: /J~air rotary [] cable t~ol [] other USE OF WELL; ~ (j0mestic ~ irrigation [] monitor [] public ~_Jpp!y [] other, CASING STICK-I fi. Diem: Casing ty OPENING TYBE~. ~: open WELL INTAKE ~r Perforate~. F'I open hole '~,= ~ ' Depths of openings: ,,~ ~ to ~ SCREEN TYEE.~ Diam: Slot/Mesh Size: Length: in. to ~O it GRAVEL PACK TYPE: Volume uae(J: Depth to top: , GROUT TYPE: Depth: from ft to ft DEVELOPMENT Duration: LEVEL AND YIELD: ft afte~ ~.- PUMP INTAKE DEPTH; __ ft H0r$opowe;: WELL DISINFECTED UPON COMPLETION? ~ YES [~ NO CONTRACTOR INFORMATION: Register~(j Business Name . / igrmture Of Authorize~f Respraae/ef&tive Date ' REMARKS: PLEASE MAIL WHITE COPY OF LOG TO: DNRIDIVI$10N OF MINING & WATER MGMT 3601 C St, Sultl 800 ANCHORAGE AK 99503.5936 Phone (907}266.8639. Fax {907)662-1384 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUM_AN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970048 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:KATHY & JAY ROWE OWNER ADDRESS:3982 EASTWOOD LOOP #B ANCHORAGE, ALASKA 99504 DATE ISSUED: 4/03/97 EXPIRATION DATE: 4/03/98 PARCEL ID:01536229 LEGAL DESCRIPTION: ROCKHILL BLK 2 LT 17 LOT SIZE: 55386 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 iqND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (iSA_AC72) AND DRINKING WATER REGULATIONS {18A3~C80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~~ i SU D BY: f DATE: DATE: CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 ANCHORAGE, ALASKA 99516 March 19, 1997 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: RECEIVED MunicipalitY of Anchorage Dept. Health & Human Services The purpose of this letter is to provide the required design narrative in support of our application for a permit to construct wastewater disposal facilities on Lot 17, Block 2, Rockhill S/D, located on Limestone Circle. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the soil log, the native material between 4 feet and 14 feet is a variable stratum of clean, highly permeable gravel overlying a gray silty sand with a measured perc rate 4 minutes per inch. Using a somewhat conservative soil application rate of 0.8 gpd/sq, ft. specified in the wastewater ordinance for soils with percolation rates of between 6 and 15 minutes per inch, this 4 bedroom residence requires a total absorption area of (4 x 150)/0.8 -- 750 square feet. The proposed 50 foot long trench design with 7.5 feet of effective gravel depth has a total absorption area of 750 square feet. The topography of the lot in the area of the proposed construction slopes down towards the southeast at 10%. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. PROP. ~ ', ', SEPTIC TANK ,' BLOCK 2 ,,, ~' LOT 10 , , NETTLETON ,' ', ACRES LOt 3A MARY~ND ', S/D LOT 27 ~.~:~(~A~)~ LOT 17, BLOCK 2, ROCKHILL S/D ~';.T ~.~ ~r~ ~ ':~,.. PROP. WELL AND SEPTIC SYSTEM ~ -. ~ - ~ ~ ~'.., ~, SITE PLAN ~- ' ~ "~;" ",' ~ F~TTOP TECHNICAL SERVICES 1 INCH = 50 FEET ~/ ~ ~ ~.~ 14530 ECHO STREET DRAWN BY TFM $~~,,._ :;,~X~ ANCHORAGE, AK ~S~O AUGUST, ~99~ ~, '.,, ~, C~ ~ ~3o2 .~ .: NOTE: THIS IS NOTA SURVEYED P~T. 4~' %, *~ ~:' f ALL LOCATIONS SHOWN ARE APPROXIMATE. 1250 GALLON SEPTC TANK 50' LONG SOIL ABSORPTION TRENCH __WITH 7.5' GRAVEL BELOW DIST. PIPE~ DOUBLE C.O. 4" DIA. D-3034 NON-PERF ~ "A" ~'- ~// 4,, DiA. F.810 PERF PiPE ~//~ :::::::::::::::::::::::: ..... ; ......................... ¢ ~'- u.T. c.o.~ 50 PLAN VIEW SCALE: i" = 50' - 0" 11. 7.5 SECTION "A - A" SCALE: 1" = 5' - 0" CLEANOUT -MONITOR TUBE qD BACKFILL 12" 1 -- )RIGINAL GROUND -- ;ILTER FABRIC DIA. F-810 PERF. DIST. PIPE 1/2" SEWER GRAVEL OF EXCAVATION LOT 17, BLK. 2, ROCKHILL S/D SEPTIC SYSTEM CONSTRUCTION PLAN AND CROSS-SECTION FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, AK, 99516 SCALE: AS SHOWN DRAWlq BY: TFM MARCH, 1997 Flattop Technical Services 14530 Echo Street, Anchorage, AK 99516 Phone (907) 345.1355 RECEIVED Lot 17, block 2, Rockhill S/D API~ 4 195 [ Limestone Circle .... Municipality of Anchorage Wastewater disposal system ]nstahauon Dept. Health & Human Services Specifications 1.0 General: 1.1 The scope of the project consists of installing a 1250 gallon septic tank followed by a 50 foot long soil absorption trench containing a total of 8 feet of sewer gravel 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform with Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary fitility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by {he construction. 2.0 Septic Tank: 2.1 The new 1250 gallon, 2 compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downstream of the septic tank. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating a trench to a total depth of 11.5 feet below original ground level in the vicinity of test hole #1. 3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. Sand for leveling or serving as filter material shall comply with Municipal specifications. 3.3 A total of 8 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 7.5 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover material shall be raised a minimum of 12 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. TEST HOLE LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH~ ::::::::::::::::::::::::::::::::::::::::::::::: ;::.':':::.:::.:::::.: !::.::::.::::.::::.: _?.::::.::::.:::...: .::'.:.::::.::::.::::.: .:::.;::::;:::.::'..;: -;:::.'.:::.::::2::; ..':::..':::;:::;:::.: ;:::2::.::::;:::; _.::::.::::.::::.::::.: ;:::.:::.;::'..;::'.:.: ;:::.::::.::'.:.:::.;: -;:::/:::;:::2:.;: ..'::::':::.:::.:::::.: ;:::.::::.:::.'.:::.;; (feet) 1 FLATFOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 17, Block 2, Rockhill S/D July 15, 1996 Pt. Jay and Kathy Rowe SM Reddish sturdy loam GP Clean sandy gravel Loose, dry will perc <<1 min./inch (stratum thicker @ N end of T.H.) SM Gray silty sand Dense, w. cobbles (see perc test data) SP Clean fine sand Dry SLOPE Depth to Groundwater Date No ~roundwater 7/15/96 Monitor tube dry 7/24/96 CO SITE PLAN LOT 1~ BLK. 2 #2 ..... i ..... i ..... i ..... i ..... : ..... : ..... : ..... : ..... : ..... COMMENTS: Perc test was conducted in SM stratum @ near the south end of the test hole. Recommend designing soil absorption trench on basis of 0.8 gal./day/sq, ft., with upper portion of trench encmnpassing faster percing GP stratum. PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~'.~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: PERCOLATION RATE 4 (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN 7.25 FTAND 7.7~ FT Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) 7/15 12" Presoak 27 3/8 Add water & start 4:42:15 23 1/2 #1 4:50:15 $ 21 7/16 I 15/16 Add water 4:50:40 23 7/16 02 4;58:40 8 21 3/8 2 1/16 Add water 4:59 23 1/2 #3 5:07 8 21 7/16 2 1/16 TEST HOLE # 2 LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) COMMENTS: FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 17, Block 2, Rockhill S/D July 15, 1996 Jay and Kathy Rowe Fill material Peat, stumps, etc Not suitable for soil abs. GP Sandy gravel Similar to T.H. #1 SLOPE SM Gray silty sand Similar to T.H. #1 Depth to Groundwater Date No ~roundwater 7/15/96 Monitor tube dry 7/24/96 Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT No monitor tube was set in this test hole due to the fact that the upper material is unsuitable. PERFORMED BY FLATTOP TECHNICAL SERVICES. I _~.,~,~ ~"~. CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: TEST HOLE FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: lot 17, Block 2, Rockhill S/D DATE PERFORMED: July 15, 1996 PERFORMED FOR: Jay and Kathy Rowe DEPTH (feet) SM Fill material Pt. SM Reddish sandy loam SM Gray silty sand Dense, some cobbles Similar to T.H. #1 SLOPE #3 COMMENTS: Depth to Groundwater Date No groundwater 7/15/~6 Monitor tube dry 7/24/96 SP Clean fine sand Similar to T.H. #1 Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT This test hole was dug to check the contiuuity of the strata encountered in T.H. #1. No GP stratum was encountered. PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~...~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WiTH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Certificate of On -Site Systems Approval OSC251522 Parcel ID 015 -362-29 Legal description ROCKHILL BLK 2 LT 17 Site address 6460 LIMESTONE CIR Expiration Date: 9/22/2026 Current property owner(s) ASPEN GROVE TRUST X The On-site system(s) is/are approved for 4 bedrooms W Conditional approval for bedrooms, with the following stipulations: Comments or conditions: No comments Original Certificate Date: 11/24/2025 This rtificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject s em(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, ev elopmentt Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Absorption Field Advisory Tank Age Advisory Other Well Flow Advisory Nitrate Advisory X Arsenic Advisory MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On-Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 015-362-29 Complete legal description ROCKHILL, BLOCK 2, LOT 17 Location (site address) 6460 LIMESTONE CIRCLE, ANCHORAGE, AK Current property owner(s) ASPEN GROVE TRUST pay phone 907-382-0333 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: FE-1 Private Well serving # dwelling units Other Non-public well as regulated by MOA ❑ Water Storage Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: 10-11 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel 11011 Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel or fiberglass older than 20 years 5. ABSORPTION FIELD: ❑ AWWTS '❑ Bed 011 Deep Trench ❑ Wide Trench ❑ Seepage Pit z Waiver request for Distance: 3 Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. F COSA Fee $SJ Waiver Fee $ Date of PaymentDate of Payment COSA # Z� X22 Waiver # COSA AppiicaUan Ap2025.doc COSA Checklist Legal Description: ROCKHILL; BLOCK 2, LOT 17 Parcel ID: 015-362-29 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 5/17/1997 Total depth 80 ft Cased to 80 ft MR Sanitary seal is functioning correctly ❑■ Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 9/22/2025 Static water level at beginning of test 45.8 ft. Comments B. TANK DATA Measured operating fluid level in septic tank NEW Date of pumping NEW ❑ Required maintenance completed, if AWWTS Comments: D. DISPOSAL FIELD DATA Which system tested (date installed) 5/23/1997 ❑ ALL standpipes present per record drawing Total measured depth from grade 12.7 ft (max) Measured depth to pipe invert from grade 3.9 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) NONE If yes, enter date Comments/Deficiencies: COSA Checklist_May2025.docx Well production at time of test 7.3+ gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes 0 No R Coliform bacteria is Negative Nitrate 9.00 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L 0 Arsenic less than MRL (ND) Collected by GARNESS ENGINEERING Date 10/2/2025 STATION ❑ Require Age of lift station Lift station maW ce co Adequacy test date 9/22/2025 Results 0 Pass Fluid depth prior to test 23.5 in Water added 750 gal New fluid depth 37.75 in Elapsed time 120 min Final fluid depth 26.5 in Absorption rate 600+ gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 99.6 in Effective depth used 26.5 in Effective depth remaining 73.1 in E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100' -❑✓ Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Disposal Field on Lot > 100' Q✓ Yes if No ft Neighboring Disposal Fields > 100' ❑✓ Yes if No ft Sewer Line/Main > 100' QYes if No ft Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft Sewer Service/Septic Line > 25'171 Yes if No ft Holding Tank > 100' ❑✓ Yes if No ft Animal Containment > 50' ❑✓ Yes if No ft Manure/Animal Excreta Storage > 100' Q Yes if No ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10' ❑✓ Yes if No ft Surface Water > 100' - ❑✓ Yes if No Field to Foundation > 10' ❑✓ Yes if No ft Tank to Property Line > 5' ❑✓ Yes if No ft Field to Property Line > 10' QYes if No ft Water Main/Service Line > 10' ❑✓ Yes if No ft F. ENGINEER'S COMMENTS Wells on Adjacent Lots: Wells > 100' ❑✓ Yes if No Community Wells > 200' ❑✓ Yes if No If tank or field is under driveway comment below ft ft ft ft G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Garness Engineering Group, LTD. (GEG) Engineer's Printed Name Jeffrey A. Gayness, P.E. In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. COSA Checklist_May2025.docx Phone 907-337-6179 Date 9 1u \ -jam*, VQ' .�.. V-1953 —_.• 0< o LICENSE�Q r0fession o #AECC884 MUNICIPALITY OF ANCHORAGE xDEVELOPMENT SERVICES DEPARTMENT i '"�1 907-343-7904 On -Site water and wastewater Section Ear: 343-7997 www.muni.org/onsite Nitrate Advisory Certificate of On -Site Systems Approval # OSC251522 Subdivision: Rockhill, Block: 2, Lot: 17 A water sample revealed a nitrate concentration of 9 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. 'Mailing Address � O gax 196650 *Anchorage, Alaska X9519 66aA �` www muni org �' Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical' methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. �Q•�� OF At 49 1H - SHANE A. HOLT..' LS -6914 5J� ssione% Lo THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOWANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. EASEMENTS OF RECORD, OTHER THAN THOSEAPPEARING ON THE RECORD PLAT, ARE NOT SHOWN HEREON (UNLESS INDICATED) NOTE. FENCELINES THAT MAYAPPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITIONADDITIONAL IMPROVEMENTS. ANYPAVING SHOWN HEREON MAYBEAPPROXIMATE DUE TO EXCESSIVE SNOWAND/OR ICE. N 89 58' 36" F 987 95 AS BUILT SURVEY 1" = 40' NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 17, BLOCK 2, ROCKHILL SUB. ( PLAT 81-143) ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE,ALASKA THIS 14 th DAY OF NOVEMBER , 2025 HOLT LAND SURVEYING 9309 GROVER DRIVE ANCHORAGE,AK 99507 14506, FB 202-32 244-73 907.223.8615