HomeMy WebLinkAboutRAYMOND TEDROW Block 1 Lot 4 S-8373  MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ~,.~ Environmental Health Division . CASE REVIEW WORKSHEET CASE NUMBER: DATE RECEIVED: COMMENTS BUE BY: S-8373 December 27, 1975 January 20, 1986 SUBDIVISION OR PROJECT TITLE: ik~> Lots 4A, 4B, 4C, 4D Bloc Raymond Tedrow · Subdiviaionl ( ~,~ ) PUBLIC WATER AVAILABLE ( ~) PUBLIC SEWER AVAILABLE ( ) COMMUNITY WATER AVAILABLE COMMENTS: A~CtlORAGE/~PES'i~RN DISTRICT OFFICE 437 "E" STP, EET~ SUITE 303 ANCHORAGE, ALASKA 99501 ! BILL .SHEFFIELD, GOVERNOR 274-2533 October 22, 1985 S & S Engineering 196x Eagle River, Alaska 99577 SUBJECT: Waiver Horizontal Separation between Wells and Sewer Main, Lot 4A, 4C & 4D, Block Is Raymond Tedrow Subdivision, Eagle River, Alaska (8621-WA-077) Dear Sir: The Department has reviewed the subject waiver request and hereby conditionally waives the horizontal separation from x,mli (Lot 3) and sewermain to 28 feet and well (Lot 4) to sewermain to 39 feet on the subject project only. This waiver is conditional on the folzowing: 1. After construction, the well casings will be required to be insDected by the engineer to determine if the casing has been disturbed. Any casings that have been disturbed will either require well replace- ment or grouting around casing. 2. Sewer main must be constructed with "Field-Lok" gaskets and heat shrink sleeves (Raychem WPC/87 or TPS) for each joint within the pro- tective well barrier. If you have any questions, please contact me at our Anchorage/Western District Office. Sincerely, Steve Eng, District Engineer SE: pkk 1,50,0 125.0 .S.T R E ET Z