Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RIVER VIEW ESTATES BLK 8 LT 6
River View Estates Block 8 Lot 6 #050-792-37 Municipality of Anchorage Page 1 of 3 Development Services Department Building Safety Division/On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 5WO10403 PID Number: 050-792-37 Name: Wastewater System: New Scott and Chrie Host tier Address: P.O. Box 772702 Eagle River. AK 99577 ABSORPTION FIELD Phone: Number of Bedrooms: Deep Trench 360-8595 Four 4 Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION .8 GPD/Ft' 7 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 8 6 River View Estates 2 Ft. 6 Ft, Township: Range: Section: Fill added above original grade: Gravel Length: 2 Ft. 64 Ft. Well: New Gravel width: Number of lines: Distance between lines: 3 Ft. 1 - FL Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Private 141 Ft. 141 Ft 768 Fe A5TM 03034 PVC Driller. Date Drilled: Static Water Level: Installer. Date Installed: Sullivan Water W 115 1/15/02 1 72 Ft. 0irtwork5 15/31-6/4/02 Yield: Pump Set at: Casing Height Above Ground: TANK 8 GPM Ft. >2 Ft SEPARATION DISTANCES Septic To Septic Absorption Lift Holding ublic /Private Manufacturer. Capacity in Gallons: From Tank Field Station Tank Sewer Une Anchorage Tank 1,250 Well >100' >100' N/A N/A >25' Material: Steel Number of Compartments: 2 Surface Water >100' >100' N/A N/A LIFT STATION Size: Manufacturer: Lot Line >5' >10' N/A N/A Gal. >5' >10' N/A N/A 'Pump on' level at: 'Pump otr level at: High water alarm at: Foundation in. in. in. None Noted Pump Make & Model Electrical Inspections performed by: Curtain Drain Remarks: BENCH MARK Location and Description: Top of Deck Southeast Corner. Assumed Elevation: 100.0 FL Engineer's Stamp OF =� 49th `� ''•�� Inspections performed by: Mike-Andemon Dates: 1st 5ML02 i••••• •••••• •• ••• ••••��•••• ........0 r 2nd 6I4L02 r ...................................... �.... �� A1ICHAEL E. ANDER; SCN Department of H Ith and Human Services approval -j �i#%:••• No. CE -4381 •,;k_, •♦�� 40 Reviewed and approved by: _ Date: �af I03 it °ROFESS�oNA:•�� ,, (Rev. IQ/99) Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW0210403 Page 2 of 3 PID No. 011-422-79 PLAN AS -BUILT SCALE 1 " = 50' AL '• 49th W ......... R';. M�CHAELE.ANDERSON G�1S ND. CE -4381 ,••� �ESS1C�� ••• Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SWO10403 PID No.: 050-792-37 V -. 2 U >: �- 'n '1111 2 PROFILE AS -BUILT 4:.,44th........ Scale: 1"= 10' NEL E. ANDERSON No. CE -4381 �ESSI 10/17/2086 15:08 6882259 SULLIVAN QiCertitieb �Driiiing .Dg by ooc Co. d" SULLIVAN WATER WELLS P.O. BOX 67DZ72, CHUCIAK, ALASKA 00587 • TELEPHONE 688-2750 OWNER OF LAND ro 4 T " ADDRESS: LEGALDESCRIPTION: %i�JBl1DjEA4J 'K P l0 1� DATE: - PERMIT NUMBER: 10 4 0 3 Deaateyof Issue *1,'5y� TAX IDENTIFICATION NUMSEA:.v�t=-�- �—L Is well located at approved permit location? ZafCs u No Method of Drilling:' rotary O cable tool Depth of wen: /U Casing'lype Wall Thickness & InCt1eS Diameter— % Inches. depth feet Liner lyper as a •• - Casing Stickup Above around: feet Static Water Levek ? °�' feet Recover Rate: gpm Method of Testing: A] ' Well Intake Opening Type open end O open hole :i Screened: Start ' ' feet Stopped feet 0Perforatiens . Start feat Stopped feet Grout lypC 4014 .aop vok Depth: from D feet. to oZO feet Well Dlshfacted Upon Completion? 4es ONO Method ofOlslnfection: CjkDORiw1C ?1;0 pofy, Comments: PAGE 02 K725 rJ�° YA t3,[li�A� ��3uyaA�� ltL�•T Sc�l�J��' ►J4 . �.� 6 pJcc. /3 'eag O G% r � Drlilees Name ATTENTION: It Is the resP"Iblllty of the property owner to submit a copy of the welt bg to the proper authority. Munlctpanty . of Anchorage Department of Health S Human Services and(or Department of Ernlrorlmental Conservation. MatSu Borough: DopartrroM of ErNi onmentAl Con.-,mallort I•d CSS211SLLOG A3lIbH'3N2109S0 NdSZ:2 9002 TT tai oaQm MUNICIPALITY OF ANCHORAGE /Lf 1p a Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW010403 Legal Description: RIVER VIEW ESTATES BLK 8 LT 6 Design Engineer: 0014 Anderson Engineering Owner Name: Scott & Chris Hostetler Owner Address: PO Box 772702 Eagle River , AK 99577-0000 �0_ ,9:3c Date Issued: Sep 27, 2001 Expiration Date: Sep 27, 2002 Parcel ID: 050-792-37 Site Address: 007300 WATERFALL DR Lot Size: 43264 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: 0 Disposal Field F✓ Septic Tank ❑ Holding Tank E] Privy Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. Received By: Issued By: Date: ( O -0 c2)� Date: -10— • Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING PGL �tilj �� Parcel I.D. 050.792.37 Permit Number SWO10403 _ Property owner(s) Scott and Chris Hostetler Day phone 360.8595 Mailing address (1) P.O. Box 772702 Eagle River, AK 99577 Mailing address (2) . Zip Code Legal description (Lot, Block & Sub'd.) Lot 6, Block 8, Riverview Estates Subdivision Legal description (Section, Township & Range) Lot Size q': a 4. ''i Acres/_�o THIS APPLICATION IS FOR: Number of Bedrooms Four Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 74-4_d� (--"7* (Signature of property owner or authorized agent) 'l n Permit Fees: 4'7 t) • 0 Waiver Fees: Date of Payment: d Date of Payment: Receipt Number: 16 7- c� 7-• Receipt Number: (Rev. 12/00) ANDERSON ENGINEERING P.O: BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) September 14, 2001 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 6, Block 8, Riverview Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 6, Block 8, Riverview Estates Subdivision intends to construct a four- bedroom home on the property. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parameters used in the design. Also identified on the plans are the location of the proposed well on the lot and the test hole locations. Existing drainage patterns are shown and will not be altered by'the development of the lot. Two test holes were placed near the location of the new absorption trench. These holes indicated poorly graded gravels and sands with a minor amount of silt. Percolation tests in the material resulted in rates between less than 1 and 7 minutes per inch. No groundwater was found during placement of the test holes, and none was noted during the monitoring period. We are therefore proposing to place a deep absorption trench system with 6' of gravel beneath the distribution pipe. The total depth of the trench will be 8'. The distribution pipe will be placed at 3' below the ground surface. In the event a deeper trench is required to provide gravity flow from the house a new test hole will be submitted with the as -built from the lot and approval will be solicited from the City prior to construction of the trench. The ground surface on the lot slopes as shown on the attached Site Plan with only shallow slopes near the proposed septic system site. The area around the trench and the home site were cleared and leveled prior to the percolation testing. The new absorption trench will be constructed on a fairly flat surface in conformance with Municipal requirements and parallel to ground contours where possible. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. Lot 6, Block 8, Riverview Estates September 14, 2001 Page Two 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, nlL� Michael E. Anderson, P.E. Attachments os:. , o� ,-\ — — ".... o0 orsz.....3•.00 0.00 �t �a. .-•o\ 1i __—`^__ lois[` may``. ..... b .. ....... C - =�� o° + `�.d•\ Well 44 w a4 .70 �\ .yO5 v / r SO I .Jo ,w b s r � 4.07'12••W 284.55 / ti CO l R Z THIS PR a w CT Q ' r / \d N04.48'39"W 245.08 NR / No OTE: F= tir 9s sof' Conflicts it/h Wells Y or septic s Area. s w in th /3 Al 74 � W O FSO �� / E Z y�� 1�^•�/wee,`. ©�� ,,'� � B � h� / r spa .9•••• ••• •••• •••• • `+ V / �p�,"� !fir 0/ .-` • •••• MICHAEL E. 11DIDERSON: Q G •�.1 ro\ <``�` �` �¢ Jam.• CE -.4381 � AV e AREA MAP\\ < M6. \ ��' PROfESS10Na,®,�•m/ ;v �°� i' I .`R / / 9" =100' CGd / QF E LOT 6' B�"�CK TES Q�vERV1Ew ESTA t C ALE i QO $ PRO LOT 6, BLOCK 8, RIVERVIEW ESTATES DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 7 Min./Inch 1,250 Gallon Septic Tank Avg. Application Rate: .8 GPD/SF 6' Drain Field Rock 4 Bedrooms X 150 GPD /.8 GPD/SF = 750 SF of Absorption Area 750 SF/12 SF/LF = 62.5 LF Trench Length Therefore: Construct An Absorption Trench 63' in Length by 3' Wide With 6' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 2' Below Existing Ground. Total Depth of Trench to Be 8' from Existing Surface. Mound Over Trench if Necessary to Provide Minimum Cover of 3'. TYPICAL DEEP TRENCH SECTION (NO SCALE) iF R© NOTE: Grade Area Over Trench to Drain Away. A,`.;`�. •:4 4,Q Minimum 6' Separation From Bedrock. �P•' /� •:5.� �� F7 Minimum 10' Separation From Lot Line. C7: 49� ��° • 1 .6.. ' ' i3ackfi:ll." s •••• ••••• •••••• •• 'y t • : MICHAEL E. ANDERSON �d ' .. Geotextile • • - �,.. � .:.Fabric -_ • 4" ' Perforated-- • - - PVC .(Slots .Down) f-' ` Drainfield = . •-i _ •,•:Rock ' • •. • . TYPICAL DEEP TRENCH SECTION (NO SCALE) iF R© NOTE: Grade Area Over Trench to Drain Away. A,`.;`�. •:4 4,Q Minimum 6' Separation From Bedrock. �P•' /� •:5.� �� F7 Minimum 10' Separation From Lot Line. C7: 49� ��° • Minimum 4' Separation From Groundwater.' ; ��• t, Minimum 100' Separation From Well on Lot. s •••• ••••• •••••• •• 'y t • : MICHAEL E. ANDERSON �d �'•. CE - 4391 ��t4LPR12ESz \ ya�J Municipality of Anchorage Development Services Department/Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw Street Anch., AK 99519 SOILS LOG - PERCOLATION TEST Performed For. Scott and Chris Hostetler Date Performed: Legal Description: Lot 6. Block 8. Riverview Subdivision SLOPE SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 OG/OL South No S L O None P 9110101 E . OF,.4 n nl ••491H ,� •,T, *-MICHAEL E. ANDERSON 'ZQ ����••. CE -4381 V�'rrf©�'•.AV 9/20/996 PROFESSWN �" L LCoc� o See Site Plan Reading Was Groundwater Net Time Encountered? Net Drop If Yes, What Depth? 20 -Sep 4:05 Depth to Water 6- After Monitoring Large Date: Boulder 1.75" Bottom of 3 Test Hole South No S L O None P 9110101 E . OF,.4 n nl ••491H ,� •,T, *-MICHAEL E. ANDERSON 'ZQ ����••. CE -4381 V�'rrf©�'•.AV 9/20/996 PROFESSWN �" L LCoc� o See Site Plan Reading Date Gross Time Net Time Water Level Net Drop 1 20 -Sep 4:05 6- 2 4:35 30 1.75" 4.25" 3 4:37 6" 4 5:07 30 1.75" 4.25" 5 5:09 6- 6 5:39 30 1.75" 4.25" Perc. Rate: 7.1 Min./Inch Perc. Hole Diameter: 6" 21 Test Run Between 3.5 Ft. and 4.0 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Performed By: gWWC. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 9114101 Municipality of Anchorage Development Services Department/Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw Street Anch., AK 99519 SOILS LOG - PERCOLATION TEST Performed For: Scott and Chris Hostetler Date Performed: Legal Description: Lot 6. Block 8. Riverview Subdivision SLOPE SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 OG/OL 13 14 1 Bottom of Test Hole 15 16 17 18 Was Groundwater Encountered? If Yes, What Depth? Depth to Water After Monitoring Date: North South No S L O None P 9/10/01 E ® O 49 TH �gt:.66...... . ..WIV. �C V, :MICHAEL E. ANDERSCN :Or ' CE - 4381 r-: 9/2�`D •' pF ' S10• •� ���' See Site Plan ®rf �_�� -.. Absorbed Water AsFast As It Was Added Perc. Rate: <1 Min./Inch Perc. Hole Diameter. 6" 21 Test Run Between 5.0 Ft. and 5.5 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Performed By: Alp WC. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 9/14/01 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 6, BLOCK 8, RIVERVIEW ESTATES SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the site plan. Work also includes the construction of a new 63' long X 3' wide X 6' effective depth absorption trench at the location shown on the Site Plan. The distribution line in the trench will be placed at 2' below the existing ground surface. Total depth of the trench will be 8' below the existing ground surface. The new septic tank and trench must be constructed outside the 100' protective radius of the well on the lot and the adjacent lots. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. ' Lot 5, Block 8, Riverview Estates September 14, 2001 Page 2of3 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. -7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). ` Lot o, Block 8, Riverview Estates September 14, 2001 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the -geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. 11 t --N Y" -"F T: N; — I P' N. -i L.._ 3" 1- a -e ICK 8=" F-1 Y" -"Y C Y -Y u..... �_° N�= CA EE DEPHF MIENT O iEf iL"FH AND Ehd�r' I F:i--ih•dl''IEh•d'FAL F iTE1= T 100 V 825 L-`' 'T'REE:T, ANC":HORAGE: Hk:. 264-4720 F -°..II EE- F F_-. N -i PA E: Nw a P -A •--•- - w I `Y" F- . - L4 E- .' Fe PERP,111- NCI. 830009 "1 APPLII_Fii'•d-r 1'iiFlhd GROSS PO E,Oex, :1161 9951—';• L CI CFIT 10 RENEWFAIL. PER1,1I1' #e;;---,0 •:=0 LEGAL 1-6BE: RIVEF:'v'IE14 ESTATES Lo -r SIZE 9S-49999 'tel>!I_ARE FEET' TYPE OF 'SOIL_ HE;'-C:IRPTION =''',' fht'1 is: TRENI'li MA'e-1.11PILlhel P•dtJMBER OF BEC:'f*:CICINS __ _ :OIL RATING (SC! 'THE REQUIRED SIZE=. OF THE ,Cl I I_ ABSOF:P"F I OP•d SYST`Eh4 .I' S : IL-° C F:-` _Y_. F-- F :-� � F-- FFA. P-4 C-6- -Y" U-1 �.:G :.: �2 9-3 6--1 "°°° �. L_ Cu �`- Y--° -1F_ Y_Y == THE LE hdCi-m D I ME P -4S I CIN :C ='s THE L P,P3TH ':: I P,I FEET) OF THE TRENCH OF., DRF! D -W I EL -C:'. THE DEPTH OF H 'rREhlCH OR PIT I:W; rHE C'ITAkIC:E BETWEEN THE SURFACE OF TETE GF":I:]E_IND FII'•11) THE BCIT"FCtl''1 OF -FETE Eex.,CA ATICII'•d '::Ihl FEET). Tf-IEF:E IS. NO =ET' wicini FOR TRENCHES. THE" 13RFI','EL DEPTH IS THE I'IDIIl'II_II'1 ClEF'TH OF GE:FIVEL BETWEEN THE OUTFALL F'IF'E: ANI'D THE BOTT011 OF THE E,> C:FI',-'ATIOPJ C.'IN FEET). JI: F ° EH. Yw w F Y Y lc:, -r- FPA F =::: 3= =Te F-.:�. == :: Y C-) CD Cl N_'a 1=0 9..__ Y_.- C-9 I --.H PERMIT- AF:,PL..ICAl,-d-I- HAS TE -IE RE:dPON IE,IL.I'T4' TO INFORM THIS, DEPAF-l"PIENT DURING 'THE INSTALLATION INSPECTION::-, OF Ah•d'r' WELLS FIC:'_AC:Et•dT TO THIS PF?mPE'F::T'•r' ANE.) THE I'•-IUt9BER OFA RE'.-IDEP-4 E= THAT 'THE I.'•IE::LL WILL SER',, -E. M........_.._._... —IF 0..4 N: -N w " > 3 "-0:=-- 0:7-a Fes. u_ `I-' JE CH F" -a "F, F -H F -r FE F R. F u:.= a N_..N T. IP" EE CA _...__. _.._... Bf'Ii_ h::F I L.L T P•dG OF' At-lY ','STEN WITHOUT THOUT FINAL I NSPEi_ T I Oh•d FI ID HPPf--.,O )AL B'.r' DEPFIF%:l"MEN-l" N'T'LL BE SUB-YEC:T TO EROSE::I::I_ITICII'•d. 11II'CI U_il''I DISTAN-,J :E BETWEEI'•d H WELL MID F1td', ON --SITE SE14AGE DI: PO'_,FIL- YSTEh'1 IS 100 FEET FOR A F'f�•::I'','FITE I. -JELL CIF:: _ 5CI TO 2f:D=i FEET FROM A PUBLIC WELL DEPEI'•dF_:'Ih�IG UPCIhl THE TYPE: OF PI_IBI..IC: WELL. 1',I T N:l:l' U_IPI D I STFIFdC:E FROVI FI PRI', FIT'E WELL TO FI PR I'vIATE SEIdER LINE IS ;W`_' FEET FIND YO FI CA.-.1111'1UN I T'•r' :=El4ER LINE IS ", FEET. WELL LOGS ARE REQUIRED AND PILISIT BE RETURNED TO THE DEPARTMENT WITHIh•d OF THE: WELL. CC 11PLETIOP•d. TITHER RE.QUIREMENTS HWY' APPLY. SPEC:I F I C AT I Ot•-IS I-IP•dD CONSTRUCTION D.T. A13F::AM ARE HV FI I L.I=1E_.t-E T'Ci INSURE PROPEF:: I I'• STALLFI"r I Clh•d. 11 Ems: u- U-0 F Nw: EE i'l ED C7 JL u :::I_.'d�A I CERTIFY THAT J.: I AN FAMIL.IFIR b.IITH THE P.,EQUIREMENT'S FOR Cltd--•E.ITE :=EP1EF:r- AND IAIE.LLS AS SE -T FORTH B'r' 'THE 19UN I C I PFIL I T',•' CIF Ah ICHORAGE. 2: I 1-111-1- I h ISTFILL THE Sl -r -TEIel IP --1 HC C ORC: Hhdi_ E WITH rHE G CIC'E.E,. I I_IhdDER.�.--,TF'-IP•dC) THAT THE ON-SITE SEWER S',•'' �TEh9 MAY REQUIRE EP•dLf'IRI EMENT IF THE F::E:'1IDEP,U:1 IS REMODELED TCI INCU-IDE 1-10RE THHI'•d EIE'C:'P.,001,1 . V- A PPL -APPL T C'A JT JOHN GROSS � (Sd- rWl DEPARTMENT Pr HEALTH AND ENVIRONMENTAL `OTECTION 825 'L STREET/ ANCHORAGE/ AK 99._1 264-4720 wF_l I ""o or4_:EF.1_ru S�;UWUFZ 1=leFz�ml_r PERMIT NO. ( 820780 ) APPLICANT JOHN L GROSS PO BOX 1161 E.R. 99577 694-9138 LOCATION LE8A1. L608 RIVER VIEW ESTATES LOT SIZE 999999 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = ] SOIL RATING (SQ FT/BR)= 105 THE REQUIRE[ SIZE OF THE SOIL ABSORPTION SYSTEM IS: ��F:I`FVA�� :51 ::_�;2 ��"%.JUlL_ r-AUF='_F" 15 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHIWFIELD. THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THEGRAVEL.DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE HND THE BOTTOM OF THE EXCAVATION (IN FEET). �FEE ��I FR'E='F_-w ���-r 11 c: -r 1=1 vi f�_ :1 2! F=7= -1 c2i CA 0 0 (--1 I t- (D r -A �� PERMIT' APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT T8 THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE F- FE C- -V 1 0 r -4!F. U��0 U I �FEE:), BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY 'THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN H WELL AND, ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR H PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL MINIMUM DISTANCE FROM H PRIVATE WELL TO H PRIVATE SEWER LINE 15 25 FEET AND TO H COMMUNITY SEWER LIME IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. ��F, I -el I -F ��F:� 3: F;;� F=:iE; ���E: r-l��r=- R. ��" ���22 I CERTIFY THAT 1: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE W%TH THE CODES. ]: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN ] BEDROOMS. � /7,/' 7� ` �7 - SIGNED:~ / f ~�����_�����-~��~��~~���~���~ / `7'�- {) / ��1// /LICHNT JOHN L GROSS ' ~ ' ISSUED BY_- V4L0 Russell Oyster 694-2774 O & E ENGAEERING & ®EVELOa MENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Performed for: Name: Mailing Address: Legal Description: SOIL LOC Earl Ellis 688-2280 Tel. No.&C?4/ Sz-j`/ -A-, . `i";PS 7 7 Depth (feet) soil Characteristics 0 2 Id 6 3 L G--,6 4 ez) I-rIXI 5 8 /I s I 10 PLOT PLAN /foC't�� 12 13 PERC. TEST 14 15 16 a •y ' 1 eo+Ge+uv fl 7 Ground Water Encountered: Yes NoIf yes, what depth dlyf� � yx •= F? � �' i I � � 3L ' '? Proposed Installation: Seepage Pit Drain Fieid t-"'� �,P ;— i` R� �C` � r• *., ;, , u E`er Comments: r.,, T,r; 5�•.:.:� i.. c:>5ra, ,�<T Performed by: Date:Jc 2, X45. Municipality of Anchorage Development Services Department Building Safety Division Onsite Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-_4°IZ- 31 COSA# 1. GENERAL INFORMATION Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address RVERVIEW ESTATES SUBDMSION; LOT 6. BLOCK 8. 21515 FALLING WATER CIRCLE • EAGLE RVER, AK 99577 SCOTT HOSTETLER Day phone 696-2422 21515 FALLING WATER CIRCLE • EAGLE RVER, AK 99577 Day phone 205 E. BENSON BLVD. • ANCHORAGE. AK 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B welts or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined In the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time ofinstallation. Name of Firm CARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 11 Zt /dl Engineer's Comments: In conducting this evaluation, GEG, VD. attempted to provide a thorough, conscientious engineering analysts of the system In accordance with ADEC and MOA DSD Guidelines d Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily Identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test _ results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the ownerfisted above. Any reliance upon or use of this report by any otherperson orpartyis not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the filowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Reort Other \�Q�t ��YtOF1 t irif 'C,S, ON-SITE WATER AND • WASTEWATER PROGRAM ' By: Original Certificate Date: 0 (Ray. 11p5) Municipality of Anchorage ' Development Services Department Building Safety Division OnSft Water b Wastewater Program 47W Bragaw Street P.O. Box 196650 Anchorage, AK 99519-66W www.muni.aWonsite (907) 3437904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: RIVERVIEW ESTATES; LOT 6, BLOCK 8 Parcel ID: A. WELL DATA Well" SATE If A, B, or C provide PWSID# N A Well Log (YM) YES Date completed 1/ 15/2002 Sanitary seat (Y/N) YES Wires properly Protected (Y/N) YES Total depth 141 ft. Cased to 141 ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 1/15/2002 10/31 /2006 Static water level 72 ft. 69 ft. Well production a g.p.m. 4.5+ g,p.m. WATER SAMPLE RESULTS: Coliform O colonies/100 ml. Nitrate 2.SLmg./L. Other bacteria O colonies/100 ml. Arsenic: -AQugJL. Date of sample: 11/2/2006 Collected by: GEG Ltd. B. SEPTICIHOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 6/4/2002 Tank size 1250 gal. Number of Compartments E Cteanouts (Y/N) YES Foundation cleanout (Y/N) SES Depression over tank (Y/N) NO High water alarm (YM) N/A Date of pumping 11/16/2006 Pumper JR's PUMPING C. ABSORPTION FIELD DATA 108ELOW EXISTING Date installed 6/4/2002 Soil rating 4Erftllbdrm) 0_8 System type DEEP TRENCH Length 64 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth 10.33 ft. Eff. absorption area 768 fe Monitoring tube YES Depression over field NO Date of adequacy test 10/31/2006 Results (Pass/Fall) PASS For 4 bedrooms Fluid depth in absorption field before test 6 in. Water added 634 gal, New depth bin. Elapsed Time: 9 min. Final fluid depth 6 in. Absorption rate # 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YM 3 type) NONE KNOWN If yes, give date - D. LIFT STATION Date installed Size in gallons "Pump on" level at _in. "Pump OTA IAL-- — E. SEPARATION DISTANCES High water alarm level at in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankflifl station on lot 100'+ Absorption field on kri 100'+ Public sewer main N/A On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Sewer /septic service line 25'+ Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 102+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 1' Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. Engineer's Printed Name JEFFREY A GARNESS Date Ic'a1 to COSA Fee y�J Date of Payment Receipt Number Jib �� } (Rw. 11/OS) Waiver Fee $ Date of Payment Receipt Number SGS Ref.N 1066648001 Client Name Ganness Engineering Group, Ltd. Project Name/# Riverview Estates Lot 6 Elk 8 Client Sample ID Riverview Estates Lot 6 Elk 8 Matrix Drinking Water P%%SID 0 Sample Remarks: Pammeter Metals by ICP/MS Arsenic Waters Department Nitrate -N Microbiology Laboratory Total Coliform Results ND 2.86 0 All Dates rimes are Alaska Standard Time Printed Date/time 11/152006 16:06 Collected Date/time 11/022006 13:25 Received Date/rime 11/032006 10:33 Technical Director Stephen C. tide POL Units Method 5.00 ug/L EP200.8 0.100 mg/L EPA 353.2 Alloaablc Prep Analysis Container ID Limits Date Dare C (<I0) 11:09/06 11/13/06 TK E (<10) col/100mL SM209222E A (<I) 11/03/06 ALR 11/03/06 DPT O li:alnn UJnuKnt.bKlLt7 p.l 3:09p Doan Thompson 907-563-6085 p.24 10: Y[ 1'/L\ rY10i1iVi` //,JY I1GI11 ./N\Y N+nY�t a.---•--- lO.r .S I w K .tP c b IFY -THAT 1 HAVE SURVEYED THE SCRIBED PROPERTY= SCh' �'rd`t for �Rr ICR04C►iME1f�iS EXISfEO(CEPTAS 1S THE RESPONSIBILITY OF THE IMINE THE -EXISTENCE OF ANY JENANTS, OR RESTRICTIONS PPEAR ON THE RECORDED SUBDI- 'ER NO CIRCUMSTANCES SHOULD DATE: GRIDti rrri X3'7 F& IN BE USED FOR CONST'RUMON OR FOR ESTABLISHING BOUND - DRAWN. IS-�9I� S•J H1 S�sF'•......• if ;�+`�� 1 Mr'tl.YV1 ' 4- Nov 03 2006 11:51AM OSBORNE.BRILEY 9077512563 ftict 26 06 09: Up•1V DernYIJVYThompson 907 -563 -GODS . YIIli/iYYO {Yi YY H` YN'1{{ {iVW NNY.• p. 24 TcLf 1 HEP.EBY CERTIFY THAT 1 HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY AvmmA/r/�! !ate AND THAT NO FNCROACHMCFKts EXIS:rmiK AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE .EXISTENCE OF ANY EA.SEUENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA ON OF FENS LINNES,NOR FOROr USDESTABL SHINGFORUCTI BOUND- ARY LINES. SCALE, DATE: • • �4{r � GRID, J� FD I -n o G. wve i �.•i :p o 9!-ve� Hl Q. lS- 1914 r .............. i+J� ORAWN� �� IMnFxvltYI Municipality of Anchorage Development Services Department • +1 Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: GEG Legal description: Riverview Estates, Block S Lot 6 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on _ ❑ Calculation error in design. _ ❑ Additional soils information needed. ❑ Water monitoring results inadequate. _ ❑ Discrepancy in information submitted. ❑ Topographic information missing or inadequate. ® Incomplete; missing a scalable survey ® Incomplete; missing well loo. ❑ Additional adequacy test information needed. _ ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. _ ❑ Locations of all soils, percolation and water monitoring tests not shown. _ ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. _ ❑ Insufficient fill over tank or field._ ❑ Other. _ Name of reviewer: beb Wockenfuss Date: 11/30/06 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK