Loading...
HomeMy WebLinkAboutRANSOM RIDGE LT 1B MUNICIPALITY OF ANCHORAGE ,~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~ IL V..I hi SON PHONE ~ ,.t q- o7'71 ~NEW [] UPGRADE NAME MAI LING ADDRESS |JoO '~tAHON i~ LEGAL DESCRIPTION kOCATION DISTANCE TO: Manufacturer Liq. capacity in DISTANCE TO: Man ufacturer Well i Absorption area I HOMEMADE: Well Well DISTANCE TO: No. of lines Top of tile to finish grade Width Type of crib DISTANCE TO: Class inside length Dwelling line Foundation Total length of lines Material beneath tile Depth Width~'~'~ L~ L_ Material INearest lot line Trench wi~dth~ '~ ~:~ inches inches NO. OF BEDROOMS PERMIT NO. ~ I I1~.~ No. of compartments Liquid depth PERMIT NO. Liquid capacity in gallons PERMIT NO, ,~tll'"~ Distance between lines Total ef fective~b~.~r~on area PERMIT NO. Crib depth Total effective absorption area Well Building foundation Nearest lot line , Depth Driller DISTANCE TO: Building foundation Sewer line Septic tank Distance to lot Nine PERMIT NO. Absorpt on area(s) OTHER PIPE MATERIALS SOIL TEST RATING cto J · .... APPROVED DATE LEGAL Static Water Level ~%~c~ feet WELL LOG Gallons Per Minute Draw Down feet Type Material Drilled: 0 feet to 2d 2 o to 7~ Total Feet of Uasin~ , 2 0 ~U~UVAUI¥ OP ANCMORAGf · ,- I 0 1982 RECEIVED ~0 to to to Hefty Drilling S.R.A. Box 1553 H Anchorage,Alaska 99507 EIE ¢/ F'ERM I ]- t",1(]. DEF'FtRTMENT' ~ "HEFILTH FINE:, EN'v'tRFq',IMENTFIL.' ~]'f'EC'TION 8;25 "'L.'" STF.:EET, FINCHORFIGE., FIK. Pql E(E L.,. L~ R !I"-4 E:~ ,:: 81:I.:I. 25 ) 1200 I}IMONO SF' i04:1. FIPPL I CFINT WZLLIFIM 1.41 L. KI NSON LOCFIT t ON RFIHSON RIDGE LEGRL. LOT ± BLK t RFINSON RIDGE SUB LOT SIZE TYPE OF SOIL. FfBSORPTION S"r'STEM I:S,: DRFIINFIEL[:' MFI',:':',IMUM NUMBER OF' BEDROOMS = :2: SOIL F.':FITING (SQ FT,,"'SR)= THE REQUIRED SIZE OF THE SOLE. FIBSORP]"ION SYSTEM IS: E::" ~] F" 'T ~'"~ ==. 4. L- E£ P-4 C:~ '"If- ~'-~ = .... 5~c ~E: ~..~-~ ~;." F~ ,...,,°'*':'L~-. d":'S' :'SQUF~RE FEET THE LENGTH DIMENSION IS THE L. ENGTH (IN F'EET) OF THE: TRENCH OF: DRRIhlFtELD. THE DEPTH OF FI TF.:ENCH OF..' PIT IS THE [:,ISTFINCE BETWEEN THE SUF.'.FRCE OF THE GROUND FINE::, THE 80TTOH OF THE EXCFI',?FITION (IN FEET). :-Il-liE T' R E,-.-: tP,,Ii C: H! IL.J: :£ 'THE GRF-t'¢EL [:,EF"TH ]:S THE MINIMLIM [:,EF'TH OF GRFI',,,'EL BEUT'HEE:N THEE oI_rf'FFILL PIPE FIN[:, THE BOTTOM OF' THE EXCF4',,,'FrTION (IN FEET). E4.~ EZ ~_.T.,~ L~ Z:.. F: ~_-C. [:. .... EZ F -ir ::[ c: -T" ~R ~',..!~ t1<:: "2=; Z ;~ E: .".t ~Z~ ¢:Zi a:Z~ E:-~ ~-4 - ':,.- i.~'¢:~P'I-ffJ':'TPT! T'f'M "'"' '"'" ....... F'ERHi'T FIPPLIC:FII'.~T HFIS THE ........................ TO !NFORH THIS DEFI-..F.'i'MENF DURING THE INSTFtLLRTION INS'::F'ECTZONS Ih- FIN'T' WELLS FID.]'FICENT 'T'O 'T'H~S r~,:..r~.~.~T FIND :"HE Nt..IHE"..ER OF F.:ES'[DENCES THFtT THE I.,.!ELL. W. ILL .:,.-~.*=. E:F~C:KF ILL. t NG OF FIN't' '-' z, ~ .:, L.r~ PlI THOUT F I N.F-IL. I NSF'ECT 1 ON FIND F:IF'PRO',/FIL [.:.W ]'H I S DEPFIRTHEN"i" P.tl LL. BE S_ E ~EZ': 3" 'T'O F'ROSECUT 1 ON. MINIMUM DISTFINCE BETWEEN R ,t,!EL.L FIND RN"¢ ON-SITE SEWRGE DISPOSFIL SYSTEM I'::; ±00 FEET FOR F! PRI'¢FITE WELL OR ::1.50 TO 200 F'EET FROH FI F'UBLIC P.IELL DEPENDING UPON ']"HE T"r'PE OF' PUBLIC HELL.. PIINIMLIM DISTFINCE FROM Ft. PRIVFrTE HELL "FO Fl PRI',,,'FITE SEWER L. INE IS ':25 FEET FiN[:, TO R C:OHHUNITY SEWER [_:[NE IS 75 FEET. HELL LOGS FIRE REL::!UIRED RND MUIS]" BE RE:TURNED TO THE DE:PFIRTMENT HITHIN 2!:0 DFI'¢S OF:' THE HELL COMPLETIOIq. OTHER REQUIREMENTS MFI'Y RPF'L'Y. SPEC:IFICFITIONS RND CONSTRUCTION DIFIGRRi"tS RRE FI',?FIIL. F!BLE TO IN:SURE PROPER INS'rFILLFITION. I CERT I F'"r' THFIT :I.: I FIM FFIHILIFIR .WITH THE: RE:(..:!UIREMENTS FOR ON-SITE SEHERS FIND WELLS FItS SET FORTH B'Y THE MUNICIPFILIT"? OF FINCHORRC.'iE. 2: I !.,.!ILL IN.STFILL. THE S'YSTEM IN FICCORDRI",ICE P.IITH "f'HE (::ODES. :2:: I UI",IDERSTFIND THFIT THE ON-SI"I'E SEWER S'¢STEM HR"? REL.]UIRE ENLRRGEMEI",IT IF 'THE RE:SI[:,ENCE IS REHODELED TO INCLU[:,E MORE THFIN ]~: 8EDROOHS.  ll'.,rT HI L..L I FIM P.II LK iNSON ISSUED B 'T' _~ ..~~..D Fl T E -l..-O-- i~- .I -~.- J- ',,,'4. 0 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST ~SOI LS LOG [] PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13- 14- 15 16 17 18 19 20 COMMENTS /vu,-, SLOPE DATE PERFORMED: /(~ '~ITE PLAN WAS GROUND WATER ENCOUNTERED? O P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND -- FT CERTIFIED BY: ~,~,,/~ '~¢ ~' DATE: PO _ .it 6-650 ANCHORAGL~, ALASKA 99502-0650 (907) 264-4111 ()NY t(NOW~ E~i MA DEt:AR'TIVIENT OF I~EA/.TH AIXiD ENVIRQNIVlENTAL PROTECTION April 5, 1982 TO: Whom It May Concern Subject: Lot 1 Block 1 Ranson Ridge Subdivision This department concurs with Leroy Reid, Alaska Environmental Control Services, Inc., as to the adequacy of the above property's soils test. The soils log shows no additional dwellings or subdividing due to the soils test the lot will not support an additional on-site septic system. If there are any further questions, please call this office at 264-4720. Sincerely, John W. Lynn Environmental Specialist JWL/ljw ALASKA F1UIF40F1FT18F/TAL c0rITF 0L S F UICeS, IFIC. gnqineerJnq 8 ~nuJronment~l April 5, 1982 Mr. Bill WilkSnson 1200 Dimond Space 1041 Anchorage, Ak. 99502 Dear, Mr. wilkinson: I have reviewed the two soil tests on Lot 1 Block 1 Ranson RSdge Subdivision. The test hale north of the house is very good soils while the hole located north of the well is not acceptable for on site sewer systems. Based on th~se two tests there is only one site acceptable for on-site systems. Unless additional tests are made which can detect bett~r soils then this lot would probably not be acceptable to the Municipal Department of Health and Environmental Pro'6ection for further subdi%rlding. Sincerely, 1220 LUcsl 25th/~uenue ,,'/~nchor,a,:j¢, Al sk= 99503 · (907) 276-1361 Time Date Inspector rime Date Inspector Date Inspector Comments Conditional Approval Date Sewer Installed Permit No. Septic Tank Size / ~.._ ~/ Holding Tank Size Soils Rating Well To Absorption Area Well Log Received Well to Tank APPLICANT FILLS OUT LOWER HALF ONLY Phone Address Lending Institution Address , ,~ ~.., H~ Realty Co. & Agent Address -- Legal Descriptior~ Street Location Phone Phone Type p. XResidence [] Single Family - Multiple Family - Other No. of Bedrooms ~ ~'~ '~ Water,.~upply [] Individual [] Community [] Public Utility Sewao~"Disposal [] Individual [] Public Utility [] Holding Tank ATTACH WELL LOG. A well log ~s required for all wells drilled since June 1975. For wells drilled ~)rior to that date. give well depth (attach log if available.) Year Individual Installed: When Connected to Public Utility:. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. GENERAL INFORMATION (a) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Legal Description. (include lot, block, subdivision, section t.ownship, range) Location (address or directions) (b) Applicant Name ~VZ/t¢, Applicant Address (c) Applicant is (check one): Lending Institution []; Owner/builder/~; Buyer []; Other [] (explain); (d) Lending Institution ,/~ ~ I/¥q LC'Jr ti_to, ~ Address Telephone (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: Iff !r. o TYPE OF RESIDENCE Single-Family,j~. Multi-Family [] Number of Bedrooms -~ Other WATER SUPPLY Individual Wellj~ Community [] Public Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite ¢~' Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION ~,. As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/Or wastewater disposal system is in compliance with ail Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ~ /~- Telephone Address /~0 ~ ~ ~ ~, ~/~ ~/ ~~,r Date Engineer's Seal .. CE~ 251 DHEP APPROVAL ~ ~ ~ / ~& Approved for ~ bedrooms b~~7 ~ ~ ~ ~to Torres of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 MUNICIPALITY OF ANCHORAGI~ DEPT, OF HEALTH ENVIRONit~ENTAjL PRO'J'.~CTJO N, 264-4720 Legal Description: $'/~ A. WELL DATA Well Classification Well Log Present (Y/N) Total Depth 7~ Static Water Level ~- ~JlJ'~/¢~ Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: /~/~IV'~ 7'"~ If A, B, C, D.E.C. Approved (Y/N) y Date Completed /~/'"J'/~'/ Yield Cased to ~(-') Depth of Grouting '4//,~1 ~o ~ Pump Set At Sanitary Seal on Casing (Y/N) Y Depression Around Wellhead (Y/N) > {00 To Septic/Holding Tank on Lot /~ z~. To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line Cleanout/Manhole Water Sample Collected by Water Sample Test Results Corn ments ; On Adjoining Lots ; On Adjoining Lots A//',~j TO Nearest Public Sewer /¥'/~ To Nearest Sewer Service Line on Lot B. SEPTIC/HOLDING TANK DATA Date Installed Standpipes (Y/N) Depression over Tank (Y/N) /V Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well {~'~:~" To Property Line 7~"" To Water Main/Service Line .'~'O / Course ~/0~) z /~/~/ Size 1¢¢~¢~ No. of Compartments ~' '¢ Air-tight Caps (Y/N) ~' Foundation Cleanout (Y/N) ct/` Date Last Pumped ~/~'/~"~' ,'V'/,/~ ;for Temporary Holding Tank Permit (Y/N) ///J~ -- To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Page 1 of 2 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed /'Z./,~/ Width of Field GO Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Welt To Building Foundation Lot To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Type of System Design Length of Field -~','~ ~:l~..$~'~ Depth of Field Gravel Bed Thickness Standpipes Present (Y/N) Date of Last Adequacy Test To Property Line 7~' To Existing or Abandoned System on ; On Adjoining Lots ~ /O~¢) / TO Cutbank (if present) Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for /z Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Y' ** Gheck Permitted Bedroom Rating Against HAA Request ** I certify that I haNe checked, verified, or conformed to ail MOA and HAA guidelines in effect on Signed /~¢-~ '~, ~__~ Date -~':~/~' the dateofthisinspection. Company ,~¢~b~'~////W~'. MOA No. Receipt No. '~'~:-~c}' ~'~''~ Date of Payment .~ Amount: $ ~' Page 2 of 2 72-026 (11/84) ALASKA [ DUIRODmE FITAL COFITROL SeRUICE!S, IFIC. {~nqineerin§ F, ~nuironmentoJ Stuches M~,CH 21 1986 BILL WILKINSON 16701RANSC1VIRIDGE 99516 60091 SELLER- SArVE WILL PICK UP FRC/VlCURCFFICE LF. CC, L:RANSCMRIDGE SUBD/BLOCK I/LOT lB MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION MAR 2 8 1986 RECEIVED ADF../:~U/~'Y TEST FUR SEWER SYSTEM ADEQJ./~L'Y TEST DATE-Ma~CH 12 1986 THE TYPE OF ABSCRPTION SYSTEM IS A 5' WIDE SHALLOF BED WITH AN ~ OF 278 SQFT. THE SYSTEM IS CAPfiBLE OF /~3ZEPTING gS0 G&L~S OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 473 GA. LLC~S, BASED ~ THE TEST DATA THE SYSTEM IS /sEI~:~T/~,LE FCR A 3 BEDKNX1VI HQVE, SEPTIC TAN< .ADF.~LI.ACY THE FXISTING SEPTIC TAtq< XOLLIk, E OF 1000 IS ADF..~UATE FUR THIS 3 BEDRODM HOUSE. THE SEPTIC TAI'~K/P~ PLANT WAS PLDPF_.D ON SEPT 6 1985 , THIS REPORT DOES NDT VERIFY THE INTEO~.ITY OF THE PIPING ~ THE WATER SUPPLY CR WASTEWATER SYSTEM, FLO, V TEST ON X~.LL ~lg..LL FLOW DATE-MARCH 12 1986 A FLC~ TEST WAS PERFCRrvED ON THE XrvELL. #73 GALLONS OF WATER WAS FLIrVPED AT A RATE OF 1.8 CIZM OVER A DURATION OF 3.2 BZL1RS. THE BRA~ WAS 61 ' WITH A RF_.GDVERY TIiVE OF 120 MINUTES AND THE STATIC WATER LEVEL WAS 6 FEET. THE WELL IS ADEQLIATE I:aCR THIS 3 BEDRCXlVl I-[1VE, ENVIRONMENTAL pR©~t~C~io~ / / / Hole No. iA Sheet of , ~ _--~er at or 8' Mac. k Location Lot 1 ' Date bec'~er 23, 1975 ' Cllent p '~-~--J Co. ' Project_ Ransom Rid.~e Top ~ev ,. DItPTH CIASSIP XCAT ION SAMPL]~ pART SYSTBM .... DATA ~GE~ ~ Peats, Saturated Gravel o S tly Silty Sandy Gravels "~.'.i' 14~;~ Moist becoming wet below 18~ Bottom off te 19. Peat 20. 22. 24., ~atez 25-, Table 9A