HomeMy WebLinkAboutRANSOM RIDGE LT 2A Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page of ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231142 PID Number: 020-092-73 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New Upgrade Name DONNA L GEORGE ABSORPTION FIELD - EXISTING ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 16801 RANSOM RIDGE ROAD, ANCHORAGE ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 4 GPD/SF JTotal Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot RANSOM RIDGE 2A Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines SEPARATION DISTANCES Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well 100'+ -- 25'+ TANK ® Septic ❑ S.T.E.P. ❑ Holding ® Other ADVANTEX Manufacturer Capacity Surface water 50'+ __ ORENCO / ANCH. TANK 1500 Gal. Material Number of compartments Lot Line 1 Q'+ __ NA COMPOSITE PLASTIC 2 Foundation 1 Q'+ __ I LIFT STATION Manufacturer Capacity Remarks Advantex FAP 2.0 tank installed and with the Gal. Advantex, residence can be considered as a 4BR. Alarm location FIRST FLOOR Electrical installed by CAPSTONE Installer A+ PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Drainfield CO/MT 3034. Inspector FWCS BENCH MARK (Assumed elevation) 100 ft Inspection ection Is' 10/24/223 2nd 10/25/23 Location and description 3rd 4d' TOP OF POD ON -SITE WATER AND WASTEWATER SECTION APPROVAL `k 4 k • • •' Conditional Approval: Date t� *: 49 TH �r .....•:* r •• •••• ••••�•% Septic System Approved - Date % c 2Fz jj Curtis Huffman l� is •.. CE 128991 �� l�r� . ,12/05/23 _ AROFESSI0NAi Note: this approval does not include well permit requirements. �,t�l1�' /D-- nc in Obl 01 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / FirstWaterAK@gmail.com April 8, 2024 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: ADVANTEX SEPTIC TANK UPGRADE PERMIT – OSP231142 LEGAL: RANSOM RIDGE LOT 2A An anchored 1500-gallon Advantex FAP 2.0 septic tank system was installed for the existing residence. With the newly installed Advantex system, the absorption bed can be considered a 4- bedroom septic system. The MOA documents show that the existing septic absorption system (SAS) had 650 SF with a receiving soils rating of 1.2 GPD/SF and an application rate of 0.7 GPD/SF with the sand filter. Using a very conservative soils application rate of 2 GPD/SF that corresponds with an Advantex FAP 2.0 system, the absorption field would only require a 300 SF SAS, which is approximately half of the existing SAS. Since soil application rates do change with the Advantex system compared to a conventional septic tank upgrade when application rates do not change, we respectfully request the septic system to be designated as a 4-bedroom system. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. PID:020-092-73 PERMIT:OSP231142 FIRST WATER CONSULTING RANSOM RIDGE LOT 2A 3rd FLOOR DECK HOUSE DETAIL Scale: 1'=30' 2nd FLOOR BALCONY .4' ROOFTOP 3 STORY �'e BALCONY RESIDENCE 0 18.1 N 21.7' N _ N N 30.0' i 10' T&E EASEMENT Lot 1—B 33 O N 89.42'47" E 283.11' I WELL I z i1 0 'R-A.P. DRr'AY n r a�ve�r Z �:. _ o ^� Q 70 � p Eli 0 / Z v 4 152.1 T x N o C w / G7 TREATMENT w O 89.3 m / M m i Lot 2—A POD 0 c 45,188 S.F. O 1 ;0 SEPTIC MANHOLE Q PIPES I m SURFACE N 8fi 49'16 283.71' WATER I I I DRAINAGE DRAIN PIPE VERTICAL PIPE Lot 2—B I II � I PLOT PLAN AS BUILT —1L SCALE 10 = 50' GRID SW 3337 Project No. 2.3-252 A4 _ 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates n c . (907) 522-6476 Phone kenOlangsurvey.com 4�� Professional Land Surveyors jonathanOlangsurvey.com �� OF Al., kk travisOlangsurvey.com i • • ' • • ' �'- I hereby certify that I have surveyed the following described property: LOT 2—A, RANSOM RIDGE SUBDIVISION (PLAT No. 84-134) Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways. transmission lines or other visible easements on sold property except as indicated hereon. Dated this the �- Day of t-s 6U13A ^%b'"'- at Anchorage. Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. �# 49 TH KENNETH G. LANG 11�• N 202 .•� A r����F9F�p•�� � .'Lej •� 5�2 AW �l►�'�ofsss�>s���a State of Alaska AECC063 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231142 Work Type: SepticTank Upgrade Tax Code Number: 02009273000 Site Legal Address: RANSOM RIDGE LT 2A G:3337 Site Mailing Address: 16801 RANSOM RIDGE RD, Anchorage Owner: GEORGE DONNA L Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft Total Bedrooms: �o�p�c.nt Depai•trnent 8/14/2023 8/13/2024 45188 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: (S,5 --� � C Date: Issued By: Date: r Z� 3 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 020-092-73 Property owner(s) George Donna Day phone Mailing address 16801 Ransom Ridge Road Anchorage, Alaska 99516 Site address 16801 Ransom Ridge Road Anchorage, Alaska 99516 Legal description (Sub'd., Block & Lot) RANSOM RIDGE LOT 2A Legal description (Township, Range & Section) Lot Size 45,188 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) El Septic Tank El Upgrade Q (w/wo ADU) Holding Tank El Renewal❑ (D) E]Renewal Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. nature of property owner or authorized agent) Permit/Rush Fees: Z 2 5- Waiver Fees: Date of Payment: Z'9 Z ? Date of Payment: Receipt Number: ! 4i 03/3 Receipt Number: Permit No. S P 2 ��L1 Z Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! August 8, 2023 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC TANK UPGRADE PERMIT LEGAL: RANSOM RIDGE LOT 2A The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic tank on the above referenced lot. Due to shallow groundwater & surfacewater, we propose to install an anchored 1500-gallon Advantex FAP 2.0 septic tank system per the attached design to serve the existing 3-bedroom residence. With the new proposed Advantex system, the absorption bed could be considered a 4-bedroom septic system. We recently received additional survey data from Ken Lang & Associates, Inc that show the south surface water. A berm is proposed to be installed to direct any potential surface water northward away from this surface water and/or extend the piping of this water system to maintain 50’+ to any surface water. Please see attached design. The lot and area are served by private water and any close encroachments or separations will be verified and staked by a RLS prior to construction. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231142, Curtis Townsend, 08/14/23 FIRST WATER CONSULTING RANSOM RIDGE LOT 2A DESIGN DETAILS: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231142, Curtis Townsend, 08/14/23 3rd HOUSE DET/ Scale: 1 "=30' 2nd FL( 8ALC( -30.0'- 1 �10' T&E EASEMENT ! a I v O 'Z V) cu�vear Z s o / a W Z C o c.i / C rri }o M D M v II 152.1' Lot 2—A 45,188 S.F. & RAIL FENCE SURFACE WATER ! DRAINAGE DRAIN PIPE DUTLETS OFTOP LCONY Lot 1—B N 89'42'47"E 283.11' f N W SEPTIC PIPES f ,--WELL ! IN 69.3' N 86'4996"W �VERTICAL 28371 PIPE Lot 2—B PLOT PLAN ___ AS BUILT _X_ SCALE 2_=50, Lang & Associates, inc. Professional Land Surveyors Ln v O M O 0 / Z C o c.i / C rri fid M M 01.4 GRID — SW 3337Project No. 23-252LA2 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 (907) 522-6476 Phone kenAlongsurvey.com jonathanDiangsurvey.com �G OF Atolkk � trovis®longsurvey.com �,V• S� I hereby certify that 1 have surveyed the following described property: LOT 2—A, RANSOM RIDGE SUBDIVISION (PLAT No. 84-134) Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the _� _ Day of __ ��'� �, __ at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. KENNETH G. LANG ,'•� o. 202 PR��fSSIQNAL�A�4 State of Alaska AECC963 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" mat r'7 I`7 entered into as of this "' Day of AAtlt4t,of 20 ,�A '3 , by and between r' 1" 1w , herein the "OWNER," and the Municipality of Anchorage, herein the(), UNICIPALITY", in accordance with Anchorage Municipal Coi and (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission Ito the Owner to utilize and operate an Advanced Wastewater Treatment System (A described as AN ADVANTEX SYSTEM located at (legal description) RANSOM LOT 2A 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory, condition capable of performing as designed and producing treated septic effluent i accordance with the equipment's approval for operation in the Municipality. `� It shall be the responsibility of the Owner during the term of this Agreement to payl for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the or the manufacturer's representative will inspect and make any necessary repairs or permitted alterations to the system. s Owner acknowledges that regular maintenance of an AWWTS reduces the failure of the system, which could include sewage backup and costly repairs or replacement. (rev. 05/18/2018) Page 1 of 3 Owner acknowledges that the Municipality may request records of maintenance repairs from the manufacturer's representative or maintenance provider. 11 1 Owner acknowledges that the fine for failing to maintain and repair an AWWTS assessed in accordance with AMC 14.60.030. :( Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. % j Owner agrees that any sale or transfer of title of the property will not occur Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as by the AWWTS vendor/installer and approved by the Municipality are the goven guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of Agreement shall in no way constitute a waiver of the provisions, nor in any way the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. be a new 5. Amendment. This Agreement shall only be amended by authorized representati,74s of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall brought in the Superior Court for the Third Judicial District of the State of Alaska Anchorage. The laws of the State of Alaska shall govern the rights and obiigation4 of the parties under this Agreement. 7. Severabiiiiv. Any provisions of this Agreement decreed invalid by a court of jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05118/2018) Pa.g� 2 of 3 OWNER: By: -6166-z, � , (signature) Date: (print name) STATE OF ALASKA. ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this day of, 2023 , by _V0,A1A Ck �20Y4�C'� NOTARY PUBLIC R ALASKA State of Alaska I My Commission expires: ; iJ. d "� NOTARY PUBLIC; ` Carrie Nordlof My Commission Expires Jan 10, 2021 t MUNICIPALITY: BY: (signature) Date: 6 2 o Z3 77E2 U, —� a"-? S L -/—S E- ,:(print name) Title: (; i V 1 L C v a (rev. 05/18/2018) page) 3 of 3 Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: 5~J ~5(~4~1 PID Number: ©2LC~ -o~ ?_--'7~ ~am~ ~6'~ Wastewater System: ~ New ~pgrade 'Address: ~0 60X Z4~5~ ~,,~9~sz~ ABSORPTION FIELD Phone: ~4~-- ~ Ne. of Bedrooms: ~ ~ Deep Trench ~ Shallow Trench ~Bed ~ Mound ~ Other LEGAL DESCRIPTION Soil Rating: O,~ GPD/Sq. Ft. Total~t~Depth from O Subdivision: Depth to pipe bottom from original gra~e: Gravel depth beneath pipe Lot: ~ Block: / ~ ~t~ ~1~¢ OI ~ ~.~ Ft. O. ~ Ft. Township: Range: Section: Fill added above original grade: Gravel length: V~ ~ ~ ~ ~ Ft. ~. S Ft. WELL: ~ New ~ Upgrade Gravelwidth: i Numberoflines: aistance between lines: ~ Ft. ~ ~ Ft. B.C): Total Depth: Cas~ Total absorption area: Pipe material: . Ftc/ Ft. ~ SQ. Ft. ~O~l~= ~ Driller: ~ D~ Static Water Level: Installer: Date installed: ~i.,~: ~: ~. ~~~u~d: TANK ~PARATION DISTANCES ~Septic ~ Holding ~ S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ~~ ~ Well l~l [~1 ~ ~ ~ Material: ~ Number~of Compartments: Sur,aCe~W~t~r~ n¢~, ,OO~ -- -- '¢~¢ LIFT STATION Line Foundation [~' ~l ~ ~ ~, "Pump on" level at: ~l ~h ~r ~ at: ,u¢~l~, ~ctrical Inspections performed ~ Curtain j~t ~ ,~ ~ ~ ~, ~ Drain Remarks: BENCH MARK Location and Description: Assumed Elevation: E~~ Inspections performed by: ~"~ Dates: 1st. ,~-~-ff~ Department of Health and Human Services approval %~:;'~(?.'"' -- ...... ~'~ 72-013 (Rev. 9/91) MOA 25 No. SW950481 Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION W.O. 95082 Date 12-17-95 PID No. ®---__ RECORD DRAWING /. EXISTING BED SYSTEM ED IN PLACE MONITOR TU~-E ~ "- / ,'~ _ 4"0 CLEANOUT__ "% '~._..__/. .. ~ SCALE: ! = 20' 72-0~3 ^ (2/91) MOA 25 -....~1 N STALL 1,000 GAL. ~EPTIC TANK TANK OUTLET INVERT = 98.1 DATE Legal Description: LOT 2A RANSOM RIDGE SUBDIVISION P.O. Box 196650. Anchorage, AK 99519-6650-Tel: 543-4744 On-Site Wastewater Disposal System/Well Inspection Report Permit No. SW930481 Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION Page 3 Of 3 W.O. 95082 Date 12-17-95 P.O. Box 196650' Anchorage, AK 99519-6650' Tel: 343-4744 On-Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT gA RANSOM RIDGE SUBDIVISION PID No. RECORD DRAWING ¢, MONITOR TUBE W/ AIRTIGHT CAP LOWER 1' PERFORATED BACKFILL GEOTEXTILE FABRIC SEWER ROCK PER MUNICIPAL SPECS EXISTING oqS 0 °q' JO~f °~° 6"_ PIPE INVERT 97.0 :.:::: -.....>..-~ ~ 7:::::::::~:: :::::::::::::::::::::::::::::::::::::::::::::::::::::: :: ~ - ~i j SAND FILTER PER ~ MUNICIPA~ SPE~S , BOTTOM OF SAND ~ ~PICAL BED SECTION ~.'{ t?.,~;~ '~ Profes{~o DATE 72-013 A (2/gl) MOA 25 ~; ~!~4 0~R~--O~ Tom Fink, Mayor unicipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 DISCLOSuKE NOTICE Date: December 17, 1993 To: Ail Concerned Parties From: John Smith, P.E., Program Manager, On-site Services Re: Lot 2A Ransom Ridge Subdivision On-site Wastewater Disposal System Marginal soil conditions and a high groundwater table have necessitated the use of special design and construction techniques in building the new on-site wastewater disposal system for the subject lot. Due to these difficult site conditions, there is a possibility that this system could fail prematurely. There is no guarantee as to the expected useful life of the this new system. When this system fails the property owner will be required to install a holding tank. For a period of approximately 6 months after final construction approval of the new system, DHHS will inspect and observe the system to confirm that it is operating correctly. Proper care and maintenance of the system by the property owner is encouraged. The following practices will help extend system life: · Conservation of water use. This is the single most important factor to help ensure that this system works properly. · Annual septic tank pumping. · Minimize the quantity of solids applied to the system. This includes no use of a garbage disposal, use of single ply toilet paper, no rinsing of fat or grease into the sink, etc. · Avoid the use any septic tank additives. Ail prospective buyers of this property will be advised of this disclosure. Acknowledged by: Owner ( s ) cc: Dee High, P.E., DHI Consulting Engineers Pete Farris, Dynamic Realty 12-15-93 09:32 AM FROM M~¥ 0 MUNICIPALITY OF ANCHORAGE MEMORANDUM : December lS, 1993 To Lee Browning, Manage. r, Environmental Services _ / Nellen Burial, Mayor's Office ~ Subject : CATHY AND BRUCE ROBINSON At 8:15 this morning, I received a telephone complaint from a Mrs. Robinson. Mr. and Mrs. Robinson are selling their home, Lot 2A at Ransom Ridge Subdivision, which is now presently occupied by the buyer sD_ce November. On October 1st, they filed for septic approval which they wea~ told would only about 10 days. An eagin~ring company was hired. A month later, the engin~ring plan submitted by DHI Consulting Engineers was subsequently rejected and was said that it did not meet city code. Then, on November 16th Messrs. Roth and Smith gave verbal approvai thus on November 19th they r~celve final written approval wlth a $1,200 waiver (something needs to be done by excavator). They hired an excavator and on December 3rd at 5 p.m., without any notice, Mr. Roth stopped by, inspected the work and told the excavator to shut down the job over the weekend - without telling any one what the problem was. On December 6th, engineer met with Mr. Roth SO changes wer~ made. An inspection was made by Mx, Roth on December 9th and that verbal approval was given to husband, engir~er, and excavator who were ail present at the time of the inspection. Special sand from Palmer was purchased for this project. Now comes thc special part, they went to the post office yesterday to retrieve their mail and found a letter dated December 9th (same day verbal okay was given), postmarked December 13th from DHHS saying that it is just a temporary approval and that they need to put one and a half times monies in escrow for a holding tank and that a reinspecfion is needed six months latex. Why????? Mrs. Robinson wants to know why didn't they just say you need a new holding tank which costs about $3-4,000 to put in, and b~ done with the problem. No bank will approve this kind of transaction. Lee, Mrs. Robinson sounds like a nice lady...trying hard to just laugh about this whole mess, She never raised her voice, and I commended her for not ye!!.~ag at me. Her husband, rlght now, is at Dill Engineers. Her phone # is 345,5574. cc: Mayor Tom Fink, Tom Fink, Mayor Municipality of AaCho. rage Department of Health and Human Serwces 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 December 9, 1993 Dee High, P.E. DHI Consulting Engineers P.O. Box 111349 Anchorage, AK 99519-6650 Re: Lot 2A Ransom Ridge On-site Wastewater System Permit SW930481 Dear Mr. High: During initial excavation of the subject wastewater system~ site conditions found at the location of the proposed mound system were significantly different than that indicated by your design drawings and soil test logs. Specifically two items have caused the permitted design to be materially changed: 1. A footing drain discharge pipe and dry well was found at the proposed site of the mound during excavation of the basal area. 2. The intended receiving soil, a GW-GM material, was found to be discontinuous and at a depth greater than that shown on the soils log and the elevation of the shallow groundwater was found to be above the base level of the intended receiving soils. The high water table in this area could be attributed, in part, to the footing drain discharge. Based on these changed conditions this office will allow the construction and operation of.the proposed wastewater system with the following stipulations: 1. The footing drain discharge must be rerouted to the underground drainage pipe that runs along the south property line. 2. The basal area of the drain field must be excavated to a level that exposes the GW-GM receiving material and backfilled with a clean course sand, as specified in the special provisions of the permit, to a level 4 feet above the elevation of the shallow groundwater table. Dee High, P.E. December 9, 1993 Page 2 3. The completed system must operate for a period of 6 months prior to issuance of a Health Authority Approval. This office will issue a conditional Health Authority Approval immediately after completion of the system, however, adequate funds must be escrowed for installation of a holding tank in the event that the system does not perform satisfactorily. 4. DHHS will have access to the property to inspect and monitor the performance of the system. If you have any questions please contact our office at 343~ 4744. ~4anager, On-site Services cc: Bruce W. Robinson, Property Owner Dan Roth, Civil Engineer, DHHS PAGE 1 OF 2 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW930481 DESIGN ENGINEER:DEE HIGH ENGINEERING OWNER NAME:ROBINSON BRUCE W & OWNER ADDRESS:PO BOX 242534 DATE ISSUED:il/16/93 EXPIRATION DATE:ill16~94 PARCEL ID:02009273 LEGAL DESCRIPTION: RANSOM RIDGE LT 2A LOT SIZE: 45188 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: ENGINEER WILL PERFORM PERCOLATION TEST IN DESIGNATED RECEIVING SOILS. SURFACE WATER WAIVER WR930068 PERMITS THE SYSTEM TO BE CONSTRUCTED WITHIN 4~FT OF SURFACE WATER. PAGE 2 OF 2 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ENGINEER MUST NOTIFY DHHS PRIOR TO PLACEMENT OF SAND. DHHS MUST BE PRESENT PRIOR TO PLACEMENT OF SAND. SAND USED IN THE FILTER LAYER MUST BE A CLEAN COURSE SAND WITH 4% OR LESS PASSING THE #100 SIEVE AND 2% OR LESS PASSING THE #200 SEIVE. A SEIVE ANALYSIS MUST BE PROVIDED FOR THE SAND USED. RECEIVED BY: ~ ~ DATE: DAT .: /I--/7-?3 ?ermit' No. Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, AK 99519-6650* Tel: 343-4744 On-Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT EA RANSOM RIDGE SUBDIVISION PID No. SITE NARRATIVE Page i of W.O, 95082 Date 10-10-93 Lot 2A Ransom Ridge Subdivision is bordered by two lots. This lot has an existing house and a failed septic system. The replacement septic system is designed for a three bedroom home. WELLS: The lot bordering to the North has a well radius which encroaches onto Lot 2A. The proposed bed system will be placed outside this 100 foot radius. The lot bordering to the South has a well radius which also encroaches onto Lot 2A, however, it does not affect the placement of the proposed bed system. WASTEWATER SYSTEMS: The placement of the proposed septic system will have no affect on septic sytems or wells on either of the adjoining lots. The proposed bed system will be placed over 10 feet from the failed bed system. DRAINAGE: The lot slopes down towards the West with all wells being uphill from the proposed system. Lot 2A has a drainage pipe underground along the line labeled "swale" on the plan view. The proposed system will be placed as far away as possible from this area, but will still be within the 100 foot required setback. For this reason a waiver will be necessary. A berm will be constructed downslope from the proposed bed system to catch and redirect any potential spillage from the bed system. This will create a 100 foot length of flow before any effluent would reach the ditch line along Ransom Ridge Road. The system and any disturbed soil will receive topsoil and be reseeded to prevent erosion. o GOLDEN VIEW DRIVE EXISTING SYSTI: 30' TEST PIT_ k BED-- YSTEM 1 2" PLASTIC UNDER ROAD ~11 ,, II / / \ CREEK CENTERLINE FROM AS-BUILT RANSOM RIDGE ROAD ODHI CONSULTING ENGINEERS CML · SURVEYING · PLANNING Telephone: (907)345-1385 Fa~: (907)345-1386 SEPTIC DESIGN LOT ~A RANSOM RIDGE SUBD. LOT 21} ELEV : 87.6 'Permit' No. Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, AK 99519-6650' Tel: 343-4744 Page 3 of ? W.O. 95082 Date 10-10-95 On-Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT SA RANSOM RIDGE SUBDIVISION PID No. REPLACEMENT SYSTEM DESIGN CALCULATIONS 1. NO. BEDROOMS = 3 2. USE BED SYSTEM 3. ABSORPTION AREA = (# BEDROOMS)(150 GPD/BR) BED APPLICATION RATE = (3)(150) = 643 SF .7* 4. BED AREA = (LENGTH)(WlDTH) = 1072 SF IF WIDTH = 20' THEN LENGTH OF BED = 32.5' *1 PERCOLATION RATE MIN/INCH 0-1 1-5 6-15 16-30 51-60 GREATER THAN 60 MOUND & BED APPLICATION RATE FILTER LAYER GPD/SF NOT SUITABLE 0,8 0,5 0.4 0.3 NOT SUITABLE .7 PIT & TRENCH APPLICATION RATE GPD/$F NOT SUITABLE 1.2 0.8 0.6 0.4-5 NOT SUITABLE 1.0 m.'",.o ~e~e~eee~*eeee e~ee&ee~e~e~ee ¢ ~ ~DENNIS~ DE/E~GH/ DATE 'Permlf No. Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, AK 99519-6650 · leh 345-4744 Page 4 of 7 W.O. 93082 Date 10-10-93 On-Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT 2A RANSOM RIDGE SUBDIVISION PID No. EXISTING BED SYSTEM TO ABAND( ~Oo 3 BR HOUSE `% 95 --. ~'..PROPOSED BED'~ '%'~ ~4"0 MONITOR TUBE %. ~ ~ 4 ¢ CLEANOUT (TYP~ CLEANOUT '"-..... INVERT = 99.7... - x~...~--EXISTIN G '" '" ~'`% 1,000 GAL."- ~ SEPTIC TANK SEE NOTE 1 OUTLET INVERT = 98.75: / ... ,/ ./ BED INLET 95.0 DENNIS DATE Page 6 of 7 Permit No. W.O. 95082 Legal Description: LOT 2A RANSOM RIDGE SUBDIVISON Dote 10-10-95 NOTES: ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 15.65. WASTEWATER DISPOSAL REGULATIONS OF THE MUNICIPAL CODE AS CURRENTLY AMENDED. 2 CONTRACTOR TO EXPOSE EXISTING SEPTIC TANK FOR ENGINEERS INSPECTION PRIOR TO CONNECT IT TO THE PROPOSED BED SYSTEM. TANK TO BE REPLACED IF DEEMED UNSATISFACTORY CONDITION BY INSPECTING ENGINEER. 3 SITE TOPOGRAPHIC SURVEY CONDUCTED BY DHI ON 9-27-93. EXISTING STRUCTURES, WELLS, AND SEPTIC SYSTEMS OBSERVED WITHIN 200 FT. OF THE PROPOSED SYSTEM SITE ARE SHOWN ON DESIGN DRAWINGS. 4 ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGINEER PRIOR TO ITS INCORPORATION INTO THE SYSTEM. 5 CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY LINES, EXISTING WELLS, WATERWAYS, SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. CONTRACTOR TO STAKE PROPOSED SYSTEM PRIOR TO CONSTRUCTION. NOTIFY THE ENGINEER OF ANY OBSERVED CONFLICTS PRIOR TO CONSTRUCTION. 6 CONTRACTOR TO NOTIFY THE ENGINEER AND DHHS 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. A MINIMUM OF THREE INSPECTIONS ARE REQUIRED, THE FIRST iNSPECTION SHALL BE OF THE SUBGRADE PRIOR TO PLACING THE SAND FILTER. THE SECOND INSPECTION SHALL BE AFTER THE PLACEMENT OF GRAVEL, DISTRIBUTION PIPING, STANDPIPES, TANK, AND OTHER COMPONENTS AS SPECIFIED. THE THIRD INSPECTION SHALL BE AFTER THE WORK iS COMPLETED. 7 CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED-LINED, AS-BUILT DRAWINGS SHOWING ALL DATA AS SPECIFIED IN SEC. 15.65.F.2, 5, 4, 5, 6 OF MUNICIPAL WASTEWATER DISPOSAL CODE WITHIN FIVE DAYS OF THE FINAL INSPECTION. INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT. THESE AS-BUILTS SHALL BE USED BY THE ENGINEER TO PREPARE AND SUBMIT RECORD DRAWING TO DHHS. 8 ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN. · 9 EXCAVATE THE ABSORPTION FIELD AND REMOVE ALL ORGANIC MATERIAL. BOTTOM OF EXCAVATION SHALL BE LEVEL i AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE, AND END OF BED BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 10 PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO · 1" PRIOR TO INSTALLING THE PERFORATED PIPE. 11 ALL PiPE SHALL BE PVC CONFORMING TO ASTM D5034 OR ENGINEER-APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE A MINIMUM OF 3 FT OVER THE PIPES AND 4 FT OVER THE TANK 12 GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER-APPROVED EQUAL. LAP ALL dOINTS 2' MIN. 13 COVER THE DISTRIBUTION PiPE WITH MIN 2" SEWER ROCK, AND COVER WITH GEOTEXTILE BEFORE BACKFILLING. 14 MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 15 SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MIN. SLOPE, AND 5:1 MAX SLOPE, AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MUNICIPAL SPECS. 16 CONTRACTOR TO RECORD THE FINISH GROUND ELEVATION OVER TOP OF BED. Permit No Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, AK 99519-6650 * Tel: 343-4744 Page 5 of W.O. 95082 Date 10-10-9.3 On-Site Wastewater Disposal System/Well Inspection Report Legol Description: LOT 2A RANSOM RIDGE SUBDIVISION PID No. 4" ¢ MONITOR TUBE W/ AIRTIGHT CAP LOWER 1' PERFORATED TYP EXISTING GRADE TYP FINISH GRADE SEE NOTES 15 & 16 BACKFILL SEE NOTE 14 ,TY PICAL BED SECTION 5'-6" SAND FILTER PER MUNICIPAL SPECS BOTTOM OF SAND 9t.0 ELEV = 90.3 :-: ::~.:.:.:.:.~×d^'V~:f~'0i~: :.:.:-:.:-:: :.:.: :.:-:.:.: :.: :-:-: :.: 20'-0" m 10 MIL VISQUEEN FULL LENGTH OF DOWNSLOPE SIDE 3' MIN C ~//.~~ SEWER ROCK PER COVER ~ GEOTEXTILE FABRI MUNICIPAL SPECS /SEE NOTE 12 /~-- SEE NOTE 10 z__ q~_...._~'""O"' ~o 0 °o°q 6" PIPE INVERT 95.0 -'~'~ qg,, oqt,q~ 6" GRAVEL BOTTOM 94.5 PERFORMED FOR: L-OT LEGAL DESCRIPTION: Municipality of Anchorage · DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST D~ Su~ . DATEPERFOnUl Township, Range, Section: I 2 3 4 5 6 ? 8 9 11 12 14 15 16 17. 18- 19- 20- COMMENTS PERFORMED BY: )IT' SLOPE WAS GROUND WATER ENCOUNTERED? S IF YES. AT WHAT DEPTH? ~.-.~ p E Monilorin~? ~'~'~' Dtle: SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE TEST RUN BETWEEN (minules/inch) PERC HOLE DIAMETER -- CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/851 .i : Tom Fink, Mayor V un zpahty of Anc Department of Health and Human Serwces 825 "L" Street P,O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 November 18, 1993 Dee High~ P.E. DHI Consulting Engineers PO Box 111349 Anchorage, Alaska 99511 1349 Subject: Waiver Request for Lot 2A Ransom Ridge Subdivision Waiver Request #WR930068, PID #020-092-73 Dear Mr. High: Your request for a waiver(s) of the required 100 foot horizontal separation of a septic system to the surface water, has been approved. The approved separation distance(s) are 45 feet. This waiver approval applies to the existing septic system to surface water separation only. Any future upgrade to the septic system will require all separation distances be met or another approval from this department. Should the operation of the subject wastewater disposal system cause any contamination or degradation of the subject surface water, this waiver will become void. Sincerely, Daniel J. Roth Civil Engineer On-site Services ~nager ~gn-site Services ljm:#5 MUNICIPALITY OF ANCHORAG~ Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR~ WR930068 PID# 020-092-73 HA# Date Received: October 11, 1993 Legal Description: Lot 2A Ransom Ridqe Subdivision Engineer: Applicant: Permit Dee Hiqh, P.E. DHI Consultinq Enqineers PO Box 111349, Anchoraqe, Alaska 99511 1349 Bruce Robinson ****** ~-- Waiver Requested: leachfield to surface water of-~feet. Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: 2. Special Conditions: 3. Other: Waiver is Granted: ~ Waiver is NOT Granted: List Conditions or Reasons for above: Date: 11-1~--~3 By: ~e/of~Reviewer Rec #: 25313/583 Amount: $ 920.00 Date Paid: 10-11-93 ~T£D Mr. Dan Roth Municipality of Anchorage Dept. of Health & Human Services Environmental Services Division PO Box 196650 Anchorage, Alaska 99519-6650 Re: Lot 2a Ransom Ridge Subdivision November 10, 1993 RECEIVED NOV 1 0 1993 MunicipaliTy ot Anchorage Dept. Health & Human Services We would like to address the comments that you gave us regarding a design for the replacement of the septic system on the above mentioned lot. After looking at your request to consider a wide trench and curtain drain, I believe such a system is fiesable. To address your review comments please note the following: The first item concerns the curtain drain and the water table issue. Previous and current soil logs show the water table in the area to have a flat gradient (see attached drawing). The soils log shows the material in the area of the water table is a clean sandy gravel. The gradation we ran on this soil confirms that there are very few fines. Since water will move vertically as well as horizontally a curtain drain placed above the system will not lower the water table underneath the proposed septic system. For this reason, we feel that it would be safer to raise the system in excess of 4 feet above the water table. Section 15.65.060.1.2 requires a minimum of 24 inches of native accepting soil beneath the septic system. It does not require this material to be unsaturated. Our soils log shows that there is at least 2 ft. of accepting soil. We propose using a engineered sand layer to obtain the required separation of 4 feet between the bottom of the septic system and the water table. To be conservative, we recommend placement of five feet of sand between the bottom of the system and the water table. The second item to be addressed is the slope of 12% The municipal requirements state that a bed system is not recommended to be installed on a slope greater than 10%. The section describing a mound system does not include this stipulation. It is our understanding that this 10% requirement is for ease of installation and not for any health risk associations. In the past we have been allowed to install bed systems on slopes greater than 10% by taking precautions to keep the septic system effluent from surfacing. As the attached drawings show, the impermeable barrier and 3:1 side slopes will ensure that no effluent will seep out to the surface. PO Box 111349 Anchorage. Alaska 99511-1349 · (907) 345-1385/Fax 345-1386 The last item to be addressed is the percolation test required in the soils strata as the accepting layer. We agree that a percolation test should be run. Since the graduation shows the soils to be very clean, the risk of the soils not percolating is greatly reduced. We are requesting the design to be approved subject to a percolation test being conducted prior to construction. We feel the system as designed is the best design for this lot and is within current design requirements. I would appreciate your timely approval of this system. ddh\grh enclosures cc: Bruce Robinson Carl Abrams e:\wp51 \dhi\082er09n.wp52 Very Truly Yours, Dee High ' Civil Engineer RECEIVED NOV 1 0 199,3 M,., ;: ~aaidy ot ~¥.~cl~orage 0~;,[. H~aith & Human SerViCe.* November 17, 1993 W.O. 93082 Mr. Dan Roth Department of Health & Human Services Environmental Services Division P.O. Box 196650 Anchorage, Alaska 99519-6650 RE: Septic System Design / Waiver Application for Lot 2A Ransom Ridge Subdivision Dear Mr. Roth: As per our previous discussion the above mentioned property, this is our request for a Waiver of the 100 foot separation distance between the absorption field and a creek. We have concluded our site study and are requesting a waiver for the following reasons: The creek is not a surface water discharge, but subterranean runoff inside a pipe. There is no surface water for effluent to get into. We will construct a berm as shown on the site plan to prevent any possible overflow of effluent from reaching the creek area prior to the ditch along side the road. The surface flow distances are labeled on the site plan and are between 93 and 95 feet. We are requesting the waiver for 45 feet. We have already submitted the waiver fee along with the system design for review. Please call if you have any questions. Sincerely, DHI Consulting Engineers Carl Abrams Civil Engineer cc: Gail High, DHI D:\wp.51 klhB082ar 17n.wp5 PO Box 111349 Anchorage, Alaska 99511-1349 · (907) 345-1385/Fax 345-1386 GOLDEN VIEW DRIVE % EXISTING BED SYSTEM .30' TEST PIT RADIUS~ CLEANOU T AT UNDERGROUND DRAINAGE PIPE FROM CURTAIN DRAIN AT HOUSE BED CREEK CENTERLINE FROM AS-BUILT _ __~/ .. ~-x.x'- C~ TBM ~ J ELEV = 87.6 k 12" PLASTIC UNDER ROAD ~ll RANSOM RIDGE It DHI CONSULTING ENGINEERS CML · SURVEYING · PLANNING Telephone: (907)345-1305 Fax: (907)345-1886 2820 DeArmoun Road · P.O. Box 111349, Anchoroge, AK 99511-1349 ROAD SEPTIC DESIGN LOT gA RANSOM RIDGE SUBD. t 4 14 f~ SOILS LOG -- PERCOLATION TEST I'1 Al, lO t 4 t~ t4 SOIL9 LOG -- PERCOLATION TEST $1t~ PLAN L-'NCOUN t L-'I~O~ ir v~.q. At WllAt , ~. L~rttt? lO - P~IIcoI. AtloN IJAI~ __ l~st ImUN I~tW~r.N .~ tt AND 12-0J-1993 03: 12PM FROM D HI ONSULTING TO 5436?4( P.Oi FAX MEMORANDUM SU~E~: ~S~~ ~6~ NO, OF PAG~ FOR YO~ INFO~TION: ~iginBIDi~o~tion: ~ MMI ~ ~roy ~ R~urn ~ ~lforP~kup ~SAGE:,i PO Box 111349 Anchorage, Alaska 99511-1349 * (907) 34§-1385/Fax 345-1386 TOTAL P.01 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES On-Site Services Transmittal Sheet The attached paperwork has been reviewed and is being returned for'the following reason(s)~: Discrepancy in legal description and/or owner name. Discrepancy in number of bedrooms. Signature and/or stamp missing on Show measured distances to sewers/wells, curtain drains and streams within 200 feet of proposed system. Replacement disposal site not shown and/or tested. Calculation error in design. Show locations of all soils, percolation or water table tests. Proposed system too deep for soil test submitted. Topographic information missing or inadequate. Narrative missing or inadequate. Additional soil/perc test needed. Sand filter requirements not satisfied. Water monitoring results missing or inadequate because Incomplete; missing. Well log required. Water sample unacceptable because / / Please supply the necessary information and re-submit your request. Your cooperation is appreciated. Reviewer /~-' R~T/~ LEA VE THIS FORM ATTACHED TO PAPERWORK /ZOS-rev. 4/93 WR~ WR930068 PID# 020-092-73 Date Received: October 11, 1993 Legal Description: Lot 2A Ransom Ridqe Subdivision Engineer: Applicant: MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet HA# Permit Dee Hiqh, P.E. DHI Consultinq Enqineers PO Box 111349, Anchoraqe, Alaska 99511 1349 Bruce Robinson Waiver Requested: leachfield to surface water of 93 to 95 feet, Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: Special Conditions: 3. Other: Waiver is Granted: Waiver is NOT Granted: List Conditions or Reasons for above: Date: Rec #: 25313/583 By: Name of Reviewer Amount: $ 920.00 Date Paid: 10-11-93 October 11, 1993 W.O. 93082 Mr. Dan Roth Department of Health & Human Services Environmental Services Division P.O. Box 196650 Anchorage, Alaska 99519-6650 RE: Septic System Design / Waiver Application for Lot 2A Ransom Ridge Subdivision Dear Mr. Roth: As per our previous discussion the above mentioned property, this is our request for a Waiver of the 100 foot separation distance between the absorption field and a creek. We have concluded our site study and are requesting a waiver for the folloWing reasons: The creek is not a surface water discharge, but subterranean runoff inside a pipe. There is no surface water for effluent to get in. to. We will construct a berm as shown on the site plan to prevent any possible overflow of effluent from reaching the creek area prior to the ditch along side the road. The surface flow distances are labeled on the site plan and are between 93 and 95 feet. We have included the waiver fee along with the system design for review. have any questions. cc: Gail High, DHI D:\wpSl"dhi~082atl Please call if you Sincerely, DHI Consulting Engineers Carl Abrams Civil Engineer PO Box 111.349 Anchorage, Alaska 99511-1349 · (907) 345-1385/Fax 345-1386 Per. if No. P.O. Box 196650 * Anchorage, On-Site Wastewater Disposal Legal Descripfion: Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION AK 99519-6650' Tel: 343-4744 System/Well Inspection LOT 2A RANSOM RIDGE SUBDIVISION PID No. Page 1 of W.O. 93082 Dole 10-10-93 Report SITE NARRATIVE Lot 2A Ransom Ridge Subdivision is bordered by two lots. This lot has an existing house and a failed septic system. The replacement septic system is designed for a three bedroom home. WELLS~ The lot bordering to the North has a well radius which encroaches onto Lot 2A. The proposed bed system will be placed outside this I00 foot radius. The lot bordering to the South has a well radius which also encroaches onto Lot 2A, however, it does not affect the placement of the proposed bed system. WASTEWATER SYSTEMS: The placement of the proposed septic system will have no affect on septic sytems or wells on either of the adjoining lots. The proposed bed system will be placed over 10 feet from the failed bed system. DRAINAGE: The lot slopes down towards the West with all wells being uphill from the proposed system. Lot 2A has a drainage pipe underground along the line labeled "swale" on the plan view. The proposed system will be placed as far away as possible from this area, but will still be within the 100 foot required setback. For this reason a waiver will be necessary. A berm will be constructed downslope from the proposed bed system to catch and redirect any potential spillage from the bed system. This will create a 100 foot length of flow before any effluent would reach the ditch line along Ransom Ridge Road. The system and any disturbed soil will receive topsoil and be reseeded to prevent erosion. GOLDEN VIEW DRIVE EXISTING BED / ,.50' TEST PIT ./ / \ ~ - x LOT k BED ~ YSTEM ~ /~_ 1 2" PLASTIC UNDER ROAD , II ODHI CONSULTING ENGINEERS CML · SURVEYING · PLANNING Telephone: (907)345-13§5 Fax: (907)345-1386 RANSOM RIDGE ROAD 2820 DeArmoun Road ~ P.O. Box 111~49, Anchorage, AK 99511-1349 2B CREEK CENTERLINE FROM AS-BUILT ELEV = 87.6 SEPTIC DESIGN LOT 2A RANSOM RIDGE SUBD. .Permit' Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650, Anchorage, AK 99519-6650' Tel: 343-4744 Page 3 of 7 W.O. 95082 Dale 10-10-95 On-SiLe Wastewater Disposal System/Well Inspection Report Legal Descripfion: LOT 2A RANSOM RIDGE SUBDIVISION PID No. REPLACEMENT SYSTEM DESIGN CALCULATIONS 1. NO. BEDROOMS = 3 2. USE BED SYSTEM 3. ABSORPTION AREA = (# BEDROOMS)(150 GPD/BR) BED APPLICATION RATE = (3)(150) = 643 SF .7* 4. BED AREA = (LENGTH)(WIDTH) = 1072 SF IF WIDTH = 20' THEN LENGTH OF BED = 52.5' PERCOLATION RATE MIN/INCH 0-1 1-5 6-15 16-30 31-60 GREATER THAN 60 * I FILTER LAYER MOUND & BED APPLICATION RATE PIT & TRENCH APPLICATION RATE GPD/SF GPD/SF NOT SUITABLE NOT SUITABLE 0.8 1.2 0.5 0.8 0.4 0.6 0.3 0.45 NOT SUITABLE NOT SUITABLE .7 I 1.0 Permit No. Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, AK 99519-6650 -Tel: 545-4744 Page 4 of 7 W.O. 95082 Date 10-10-93 On-Site Wastewater Disposal SystemfWell Inspection Report Legal Description: LOT 2A RANSOM RIDGE SUBDIVISION PID No. CLEANOUT '~ ~_ $ BR INVERT = 99.7 ~' mo ~ ca HOUSE ~-~ ~ "-- / x . ,.~..~-EXISTI N G "' '~'-. 1,000 GAL? ~. '~ SEPTIC TANK ( SEE NOTE EXISTING BED OUTLET ABANDONE[ / ~ / xPROPOSED BED~ SYSTE~ ~4'¢ ~ONITOR TUBE BED INLET = 95.0 SCALE: 1" = 20' :DENNIS DATE Permit No; ~legal Description: LOT 2A RANSOM RIDGE SUBDIVISON Page 6 of 7 W.O. 95082 Date 10-10-93 NOTES: ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 15.65. WASTEWATER DISPOSAL REGULATIONS OF THE MUNICIPAL CODE AS CURRENTLY AMENDED. CONTRACTOR TO EXPOSE EXISTING SEPTIC TANK FOR ENGINEERS INSPECTION PRIOR TO CONNECT IT TO THE PROPOSED BED SYSTEM. TANK TO BE REPLACED IF DEEMED UNSATISFACTORY CONDITION BY INSPECTING ENGINEER. SITE TOPOGRAPHIC SURVEY CONDUCTED BY DHI ON 9-27-9,% EXISTING STRUCTURES, WELLS, AND SEPTIC SYSTEMS OBSERVED WITHIN 200 FT. OF THE PROPOSED SYSTEM SITE ARE SHOWN ON DESIGN DRAWINGS. ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGINEER PRIOR TO iTS INCORPORATION INTO THE SYSTEM. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY LINES, EXISTING WELLS, WATERWAYS, SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. CONTRACTOR TO STAKE PROPOSED SYSTEM PRIOR TO CONSTRUCTION. NOTIFY THE ENGINEER OF ANY OBSERVED CONFLICTS PRIOR TO CONSTRUCTION. CONTRACTOR TO NOTIFY THE ENGINEER AND DHHS 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. A MINIMUM OF THREE INSPECTIONS ARE REQUIRED. THE FIRST iNSPECTION SHALL BE OF THE SUBGRADE PRIOR TO PLACING THE SAND FILTER. THE SECOND INSPECTION SHALL BE AFTER THE PLACEMENT OF GRAVEL, DISTRIBUTION PIPING, STANDPIPES, TANK, AND OTHER COMPONENTS AS SPECIFIED. THE THIRD INSPECTION SHALL BE AFTER THE WORK IS COMPLETED. CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED-LINED, AS-BUILT DRAWINGS SHOWING ALL DATA AS SPECIFIED IN SEC. 15.65.F.2, .3, 4, 5, 6 OF MUNICIPAL WASTEWATER DISPOSAL CODE WITHIN FIVE DAYS OF THE FINAL INSPECTION. INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT. THESE AS-BUILTS SHALL BE USED BY THE ENGINEER TO PREPARE AND SUBMIT RECORD DRAWING TO DHHS. 8 ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN. 9 EXCAVATE THE ABSORPTION FIELD AND REMOVE ALL ORGANIC MATERIAL. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNINO, MIDDLE, AND END OF BED BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 10 12 1,3 1,4- 15 16 PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO + 1" PRIOR TO INSTALLING THE PERFORATED PIPE. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D5054 OR ENGINEER-APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE A MINIMUM OF 5 FT OVER THE PIPES AND .4 FT OVER THE TANK GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER-APPROVED EQUAL. LAP ALL JOINTS 2' MIN. COVER THE DISTRIBUTION PIPE WITH MIN 2" SEWER ROCK, AND COVER WITH GEOTEXTILE BEFORE BACKFILLING. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MIN. SLOPE, AND 5:1 MAX SLOPE, AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MUNICIPAL SPECS. CONTRACTOR TO RECORD THE FINISH GROUND ELEVATION OVER TOP OF BED. , Permif No Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 ° Anchorage, AK 99519-6650 ° Tel: 343-4744 Page 5 of 7 W.0. 95082 Dale 10-10-93 On-Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT 2A RANSOM RIDGE SUBDIVISION PID No. 4" ¢ MONITOR TUBE W/ AIRTIGHT CAP LOWER 1' PERFORATED TYP TYP FINISH GRADE' SEE NOTES 15 & 16 BACKFILL SEE NOTE 14 EXISTING GRAD -:.:.:.:. :-:.:-:. :.:.: :.:-:../: :.:-:.: :-:. :-:~c~ ~,~..:.:.:.:.:.:.:.:.:.:.:.:.:.:.:. :.:.:.:.:.:.:. ~ 20'-0" ~. -=' '10 MIL VISQUEEN FULL LENGTH OF DOWNSLOPE SIDE NTS TYPICAL BED SECTION ,3'-6" SAND FILTER PER MUNICIPAL SPECS BOTTOM OF SAND 91.0 ELEV = 90.5 3' MIN ~ SEWER ROCK PER 5'-0" COVER /"-- GEOTEXTILE FABRIC/ ~.,---- MUNICIPAL SPECS ..~_1 /SEE NOTE 12_~ ~-"'" SEE NOTE 10 ..... Z___---_/ °%¢.~?~--'-~o°-0 0°¢ ~i P,PE ,NVERT 95.0 _ .----"'~ q~, oq~q~ 6 GRAVEL BOTTOM 94.5 PERFORMED FOR: Municipality of Anchorage DEPAR. T.MENT OF HEALTH & HUMAN SERVICES 825 L Slreet, Anchorage, Alaska 99502-0650 so,.s LEGAL DESCRIPTION: Township, Rahge, Section: 2 3 4 5 6 7 8 9 11 13 14 15 16 17 18 19 20 SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? ~--S S ~F YES. AT W.AT I O~ DEPTH? '~..-~ p E Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE __ (mmutes/inch.I PERC HOLE DIAMETER __ TEST RUN BETWEEN COMMENTS PERFORMED BY: I FT AND __ FT S~¢=_ ~*~A~ I~uM . CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE; 72-008 (Rev, 4/85} Ill J  /~% MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PHONE I [~ NEW MAI LING ADDRESS ~J LEGAL D ESCRIP~ON I NO. OF BEDROOMS I we,, , Absorption ~e~ i Dwelling /~, PERMIT NO. ~ ~ DISTANCE TO: /¢¢ ~ ~ Manu,acturor ~ Mater'a~ ~I~ , ,o. of comoartments kiq. caOacitg in ~allons Insido length ~iOth Liquid de~th }OO~ / IF HOMEMADE: ~ ~ DISTANCE TO: Well Dwelling PERMIT NO. O ~ ~ Manufacturer Material Liquid capacity in gallons Q Well , t ~ Foundation .~ ~ Nearest lot line~ / PERMIT NO. No. oflines~ Length of each Une ~' Total length of lines z~ ~width ~ Topoftiletofinishgrade~/ ~O' ~Z~ ~ 8e~ I~ Material beneath tile Total effe[tive absor~ti~ area Length Width Depth PERMIT NO. ~ ~ , Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to Jot line PERMIT NO. ~ DISTANCE TO: . Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS SOIL TEST RATING . INSTA~ER ~ REMARKS '~ ~ - DATE LEGAL APPROVED DEPFtRTHE:NT ..... FI[.:..'AL. TFI FJND ENV I RONI"IENTFIL. ~.. r,.!OTECT I OIq ',E:;2.~; '"L"' '.'5]"REET, FiNCHOF.'.FIGE., RF::: ;,Z6,:~---q. 72EI FINCHORIqGE 674-;:_"13:::L : EFIGLE RIVER F_'",II"..,~ ........ :..:iL::; :It:: T'E: ~:$E[tl....~ E:Fe F':"E:IF~-_" ~"-11Z 7" F'ERH I T 1'.,I0. 83::1.:I. 2;2: FIF'F'L I CRi'.,IT: DEt.,.IFI'T'NE i:::'F:I'¢NE F'HEINE: FIDDRE.'.'5.'.':~;: :J.. 7' ::L :L ."~; BF.::t.."iGI:::H.,.I FtI'.,I C:Ff 01:~! Fi G E., RI-::: LEGF!L DE~;CRtF'"FtON -.- :~;UBD]:VIL."-.';:[ON: RFIN:E..:OH RIDGE BLOCK: NFl LOT: L. OT SiZE 99C~E'~'3 ~'::;Q. F:'T. :~ o~'/J¢¢-...~ TONN"ZHIP: .... RRNGE: -- ?:,ECTION: -- HFi;:.:',]:I',-IUH F,ILIi"!I:3ER OF E:EDFJ:OOH'..:]; =: ~.':) :J.~;OiL F.:FtTING '-'= 0 0 0 ,::.,..'~,l.~..i. FT. LISTED E:E:I....ON Fd:;..'.E THE OF'T]:Qt'.,t'.'~; FIVF:iIL. FtBLE "FEi YOU IN DESIGNING YOUR ~,EPTIC 9'¢:i~;TE:r'l. Ct..-IO09E THE OF'TIOlq 'THFIT BEST F-"'I"FL:., '.fOUR SITE. ]: CERT I I::"¢ THFtT: ::L. I FIH F:F:tHILIt::tt:~: I.,.IITH TFiE F.'.'Et;!UtREHEI'-,IT::.:~ FOR ON~~'.:qITE ::-;EI.,.IE~R:~; FIND !4ELL~5 FI::"'; '.."5,ET FORTH .E,"¢ THtE I'"II..II'.,IIC:IF'FtLIT',r' (:.ii.:' I::INCHL-.IRi::IGE l:::llqD THE :~,TF.f"]"E OF' FtLFISI<:FL 2. ]: HILL INS'I"FtLL THE !:?,'.¢!S'I"EH IN I::fC:C:Ot:;;:DI::tNCE I.,.IITH "FHE CODES FiND HF:IVE RECEIVED FI CGF'"r; Of:' THE C:ODE '-'-.q. JHI"IF:tF'::V F'IND D.'[RGF.:FtH FITTRCHHENT'_.-"; NHICH I'L'; PFIRT OF THI'5 F'E F.':H l T. Z.'.. I UNE:,EI.';'::'~;T'FtND 'THFI'I" THE Oi'.,i.....:..:i;tTE :.5[:'i.,.IEI;.'. S"r".~;TEH HI:-"I"r' REQUIRE ENLFII:['.I3EHE:NT IF' 'THE RESIDENCE I:{; REHODELED TO INCI._LtDE i"IOF.':E THRN ~ BE:E:,RF~OI"I'":;. t::"'ERH.T.T ~:tPPL. IE:Rt",I"F HFrZ..:, THE F.".Et~:";F'Oi'.,I'.E;,IBILIT'.r' 'FO INFORI"I PE:RSONI'.,IEL [.',UR:lNG THE INSTRL. L. RTION INSF'ECTION.':_':; O1:: RN"r' L,.tELLS FID..'rRCENT TO THIL=; PROPERT"r' RND THE i'.,IUHBER OF' I:;.':ESIDENCE.'E; THF:IT THE t.4ELL I.,-!ILL SERVE. :[t:: F:t L. IF'T :.:.';TI::ITIOI'.,I I:5 INS-I"F:ILL. ED., FIN [."[L. ECTRICi::IL PERi'II.T FIND IN:51:'EC'TZON i"IU2;T DE!: OE,'TRINED. RCFJ;.....BLIIL. T::.:'.'; CF:INNOT BE: Iat::'F'RO',,,'ED NITHOUT lan ELECTRICRL INSPECTION REF'ORT. THE ELECTRIE:IaL. NORt< HUST BE DONE B'¢ FI LICEI'.,tSE[:, ELEC"f'RICIRN. :.::: I GNEI::,: FIF'PLICFtNT: E:,ENFt'T'NIE F'FI'.r'NE I '.E;:..SUEr_':, BY: DFITE: -~M~UNICIPALITY OF ANCHORAGE-~, Department' £ Health and Environmenta ~rotection~ 825 ,, Street, Anchorage, AK. 99501 264-4720 Permit" ~ ~ {/~7~ * * * HANDWRITTEN PERMIT * * * WELL AND~ ON-SITE SEWER PERMIT Applicant: ~LO~ Location: Legal Description Type of Soil Absorption System Is: Phone Number: ~ ~- ~ ~/J~ LOt Size: Trench: Drainfield: Maximum Number of Bedrooms: ~,~ Seepage Bed: ~ Holding Tank: Soil Rating(sq.ft/br) /~ ~ The Required Size of the Soil Absorption System Is: DEPTH LENGTH GRAVEL DEPTH WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDiNG) TANK SIZE = /6q-~b GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent ~o this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 1 9 $ 3 * * * Z certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if :~_residenc~modeled to include more that 3 b~ooms. . SWP/024(1/81) * f ~. SOILS LOG PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16- 17- 18- 19- 20 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 ' SOILS LOG- PERCOLATION TEST ~J SLOPE F,'ll DATE PERFORMED: [] PERCOLATION TEST SITE PLAN WAS GROUND WATER ENCOUNTERED? AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop ,..' PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND -- FT ~;~k ~l ~.~ so.~ To ~ a~ ;.s%ll ~, ~ ~,'~ = I~ x I,~ X 3 = ~3~~ PERFORMED BY: t JQm~- / . ~/VO/~ ~ CERTIFIED BY: _DATE: ~8~ z ~ ,-~ ~ 0 0 0 0 ~4. "0 0 0 0 r~ ~D 0 q~ 0 c~ �� co m O O 0) CY) LU c P � o LLL V s I..L 0 �U z LL a� 0 F— CL U a) N ®art U) ® Q � z M a) (3) cf) U 06 U) c � E� Q O 00 C6 0 Q Q a) U) a) +- U) c 0 0 a) m U a) LN m N O N N (Y) N cu C O m .Q X W O O O i C'7 ti N m O O N O 0 a) L cu a_ Q N J W 0 z c O .2- U U U) a) (5 J O T— O7 Q a) c� L 0 U W 0 0 U) Q O 00 (D T— U) N cu U) m II r-, u • M 0 0 a� O CU a) cu D /1 C/) N U) a O () c 0 a) t H x �+ u d 0 O (n m E 0 A 4-1 L) O 0 O >, O. y C) a �- O 3 -C V y V N cu i L N 0 ~ co O ~ a) L 0 � 0 N 0 C '5) .0 N N O V = a L2 C Q ,N O O 0a) U) a o O m. > O (� cn N CO 0 N Z: O _0 Q U ^ Q N LL cu = N 3 0 'u� Z Q � > i cu 'E O C Q oami .Q Lo CL Q. E c- m N I- < N C O O X aa) A -j N RT �-• i O N C ca L O 0 -� O a) -0 N > N E -0 O Q O Q 0 Q N cin 0 U) O > Q U LL C = U ° CD 44 v m N O N H Q Q - Q Z (n O L O Y a) cu r—m cW C = U F- Q 0 U � � aNi .� U N 0 ``a^) 06 VJ L a) E3: Q.. o a) a ❑O O M U 0- 76 (6 O Q. Q U) 0) 4- cn N CO CL O O N U WA Z O a � N O LL Q Z o 6L C) W Z v W 0 a- T- U) Oil tW V a_ r �.i a) a) C L - TO i a ..O V N Z N U. O �_ s I_ J Q^ .0 � N H OJ U a) (1) CO U N 2 L Z O Co LU m' a) co c o Q � O U CD coo u O a) co o cu z pLL .-. u, a) c O > t:• Q ov/ Q a) L U U C6 •L ``a^) 06 VJ L a) E3: Q.. o a) a ❑O O M U 0- 76 (6 O Q. Q U) 0) 4- cn N CO CL O O N U WA Z O a � N O LL Q Z o 6L C) W Z v W 0 a- T- U) 0 a) LL a) 0 a) LL CO O cn � =i r � a) a) C L - a ..O N W N O U a � N H OJ � O W W W N 2 a) ❑ n U) O 0 W C7 LU m' a) co c o Q � O U CD coo u O a) co o cu z pLL .-. u, a) c O > t:• Q ov/ Q a) L U W N fn U) `W '�' W cnW O J d � U) LWL r a u' O a) N M 0 a) LL a) 0 a) LL CO O cn � =i C L N O _ U) O N U a) C O N y_ O ❑ C (6 .0 E i U L O N O E O a) L .Q ❑ (D� C C U) O cn N E :3 >E O 0 N > El U Q. a) ❑ ❑ ( U () Q � c 0 D U O LL O V c) a) ❑ N Q CD U) N 7 a) N ❑ _0) O (1) .L O U i a 0(3) 0 ElU m 0 a0. —'- ❑ o Q ® Q. (10 a) a) U C/)►�- °- � a � El FE ®a Q Eld W U -LU ® d t U)F- N O >' W El Lu N V V! _W L a Y Z Z O o L a a U)�- LL H � a � a a) WV Z w ct LU 0 .� a a) cOn i � a. H Q Q > N M a`> WQ > ui co w m 0 a) LL a) 0 a) LL CO O cn � =i COSA Checklist AX copy.docx COSA Checklist Legal Description: RANSOM RIDGE LOT 2A Parcel ID: 020-092-73 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled 12/8/1983 Total depth 242 ft Cased to 20 ft (INTO BEDROCK) Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 6/1/2023 Static water level at beginning of test 90 ft. Well production at time of test 2.9 gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 4.35 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 3/29/2024 Comments B. TANK DATA Measured operating fluid level in septic tank NEW Date of pumping NA – ADVANTEX <1YR Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed. Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 12/16/1993 ALL standpipes present per record drawing Total measured depth from grade 4 ft (max) Measured depth to pipe invert from grade 3 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective (ED). If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 6/1/1023 Results Pass Fluid depth prior to test 0 in Water added 600 gal New fluid depth 1 in Elapsed time 1200 min Final fluid depth 0 in Absorption rate 600 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 6 in (MOA 0.5’ ED) Effective depth used 0 in ( Final Fluid Depth) Effective depth (ED) remaining 6 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots & appears approximate. New Advantex FAP 2.0 tank installed in fall of 2023, making this a 4BR septic system. COSA Checklist AX copy.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No *50+ ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No *50+ ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No *50+ ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No *50+ ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS *MAY MEET CONVENTIONAL SEPARATIONS, BUT SYSTEM MEETS CATIII SEPARATION DISTANCE REQUIREMENTS. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 4/24/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 4/24/24 r-+ U C b cOH U � + O ..0 '9—."cd cd 0 a, �' " y � 'o C O O N Cd cdU cd E U " y 4 E cd N . 0 y s, (U41 'd U cid cn > yO„ O N O >1U eD `d ed ,C b a. r F 'd z > b4 o oC14`d ao o a 0Uai 3 -d -d .- o o cd CU o 1 C13cd �. `d.b" i o pa°n >U) 0 O oGe U Cd p cdco a� `o -d cd Cd ro rn cd 0 aco o dCd o C14 P. U _ � °' r o 4. -d 0 CO H U Cc o cd ° "ZI Cs cd Cd cd Cd P4 41 C,3 cd 41) Cd in ¢N ti V co cd °�' o N c o i., -d 00 E 0 0 y C14�+ cd cd N n rn CJ °�•'1p,3 cd Cd i 4" U o }; rn C;3 O rte. Cd O b N m N O U N cd � Y a .� a� a. U 3 a. .. �. O 1 1 O N 00 O .(1) N 0 >, N C) ° ° Id 0 Cd v N o co W U b bA cij v d �" Cd�- o N ° U cn Lr) M kn (U cd °' A ) y Cd A. h d [� cn (I I.L.(A ca Cd Cd d U O W >-O LJJ z Q z Q • is v Cd 0 Q N LLJ C7 O Z Q d c r. Q i. r-+ U C b cOH U � + O ..0 '9—."cd cd 0 a, �' " y � 'o C O O N Cd cdU cd E U " y 4 E cd N . 0 y s, (U41 'd U cid cn > yO„ O N O >1U eD `d ed ,C b a. r F 'd z > b4 o oC14`d ao o a 0Uai 3 -d -d .- o o cd CU o 1 C13cd �. `d.b" i o pa°n >U) 0 O oGe U Cd p cdco a� `o -d cd Cd ro rn cd 0 aco o dCd o C14 P. U _ � °' r o 4. -d 0 CO H U Cc o cd ° "ZI Cs cd Cd cd Cd P4 41 C,3 cd 41) Cd in ¢N ti V co cd °�' o N c o i., -d 00 E 0 0 y C14�+ cd cd N n rn CJ °�•'1p,3 cd Cd i 4" U o }; rn C;3 O rte. Cd O b N m N O U N cd � Y a .� a� a. U 3 a. .. �. O 1 1 O N 00 O >, .d b04-1 y N O i N aCd i a� o U a� coi �o �, '' s� 03 -'4 o a v H > F� s � cd' cd cd 4, y ° °� cd O 3 cd N &, bA O bD � �+ ,cn cn >, sem. v� cil > y^ cd ccs 03 p O co co ;:j�' s~ N N N Q N + .fl pUU -d N y CJ U N Gc7 'O 'N p> s 4-400Cd Cd ccO a) .btd O tN 0> bb c�O N > p y, ~ �+LU" 0 &. 9 ar cd >~' 00 cd fin. y S~ f ." N + .d d `� CO3 0 cz r bo O U in xi 0 UN ° 'C7 O p O N b s?+ O caN cd N N N N to m cd U-14 y yU Cd Q w N 3 s~ r, �R++ N Cdcd p cd cd Q4 �', cd `� ,' ¢+ '" y q s+ .Ocs to cd _U VIC C > � "O ice+ 'U _� ° 'd s. >, r, ^' ;5 N 4-' `n to y r. cid cd ". >~ CS ° o3 O o aicz �+ cd Cd r.° v °° a°i o 4.1 tb cd tb a H a o a o i P4 CO y rn o o ai a� a� �+ a� a� d „ o bo U; bo Cd +3 bo i to En H ► a� > +�to ° Cis 4� cd b cd cd U cd Q' cd S�, �•• b °' O v. +� cd 00 � -. COD En cd od0 3 'b s� ccs N ��, U > d 0cis 0 U U � � N 00 � O d 0 0 0 .0 W O HI 41" .� a. rig ^, v7 0 w OI -b F" Ea M 4-i O M N by Cd a 0 0 N 00 tn 0 ani i v� U c \I• 44 O Q n ba _vt Cr.. = w s W CD L E �0 o CP �z� �c E �! (, 4° bb bn U U ca 'a Cd g ... �.j cn �UE—� 4° TI� N H N M 4-i O M N by Cd a 0 0 N 00 tn 0 ani 3rd FLOOR DECK HOUSE DETAIL Scale: 1'=30' 2nd FLOOR BALCONY .4' ROOFTOP 3 STORY �'e BALCONY RESIDENCE 0 18.1 N 21.7' N _ N N 30.0' i 10' T&E EASEMENT Lot 1—B 33.0" N 89.42'47" E 283.11' I WELL I z i10 'R-A.P. DRi'AY n r a�ve�r Z �:. _ o ^� Q 70N � p Eli 0 / Z v 4 152.1 T x N o C w / G7 TREATMENT w O 89.3 m / M m i Lot 2—A POD 0 c 45,188 S.F. O 1 ;0 SEPTIC MANHOLE Q PIPES I m SURFACE N 8fi 49'16 283.71' WATER I I I DRAINAGE DRAIN PIPE VERTICAL PIPE Lot 2—B I II � I PLOT PLAN AS BUILT -1L SCALE 10 = 50' GRID SW 3337 Project No. 2.3-252 A4 _ 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates n c . (907) 522-6476 Phone kenOlangsurvey.com 4�� Professional Land Surveyors JonathanOlangsurvey.com �� OF Al.,_4' kk travisOlangsurvey.com i • • ' • �'- I hereby certify that I have surveyed the following described property: LOT 2-A, RANSOM RIDGE SUBDIVISION (PLAT No. 84-134) Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways. transmission lines or other visible easements on sold property except as indicated hereon. Dated this the �- Day of t -s 6 U 13 AA fShc4k - at Anchorage. Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. �# 49TH KENNETH G. LANG 11�• N 202 .•� A r����F9F�p•�� � .'Lej •� 5�2 AW �l►�'�ofsss�>s���a State of Alaska AECC063 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING ~)Z.C2-- O~-~Z----'7.~ HAA # P/~ ~30'7~O 1. GENERAL INFORMATION Complete legal description m Location (site address or directions) Property owner Mailing address Lending agency Mailing address Day phone_ Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- lng to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer RECEIVED DEC 2 2 1995 Municipality oi Anchorage Dept. Health & Human Services NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21  COMMERCI~ TESTING & ENGINEERING CO. AK D~ ' - CHEMICAL & GEOLOGICAL ..-., . Drinking Walor~Analysis Hepon lor Total Coliform ~oto~a TO BE COMPLE3ED ~Y WA~R SUPPLIER TO BE C~PLETED BY ~BORATORY 8AUPLE ~PE: Time ~lwd , Re.file Anal~l ~th~:.. ~nbrona Flaer Che~k ~le (lot ~utlne ~mple with lab r~. no. ) [3 Tllaaled Water Special Purpo~ .::.- ~ Un,eared Waler ' Nu, of ~lonie~ O0 mi. 5AMPLE Ti~ c~ Lab ReL Ne,s ~_. ~lt* Anal~t A.D.E.C.~ BAGERIOLOG~AL WATER AN~Y~IO. ,. RECORD COLLECTING SAMPLE rl..~ U*~mno FiI~ ~lla) ..... _,~;' :_ ' .... TNTC = Too Numerous To COUnt ~mo: OB = Other Bacteria ,~..::... ... ...:. ~ .. PART fiNE OF T~O: ~~ MQmbm~he~G~G,o,,P(Soc REUAINDER TO FOLLOW STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained fi'om the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ~)/.~'_,~- ~_C~"/___~,/~,,/',/v/~ ~--~'-/~/~,4¢~ Phone ~' ~ - /'~ ~ Address ~ ~ ~0 ~ ~ ~ Engineer's signature ~~;. Date /¢-~/- ~ 7 DHHS SIGNATURE Approved for Disapproved. bedrooms. Conditional approval for -'~ bedrooms, with the following stipulations: Additional Comments By: ._1 oH-~ ~:mt:yr-h Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-~25 (R'ev. 1191) Back MOA ~21 Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: A. Well Data Parcel I.D. Well type Log present (Y/N) Y Total depth sanitary seal (Y/N) If A, B, or C, attach ADEC letter. ADEC water system number Date completed / o2- ~'- ~.c,~ Driller Cased to ~ ~ Casing height Wires properly protected (Y/N) AT INSPECTION Date of test Static water level Well flow Pump level1 SEPARATION DISTANCES FROM WELL TO: / Septic/holding tank on lot ! / O Absorption field on lot / .,Z 5' / Public sewer main /J/A Sewer service line c~ o / FROM WELL LOG g.p,m. G 4//.. g.p.~o~, ; On adjacent lots /0o / -/~ ; On adjacent lots Public sewe~ manhole/cleanoUt Petroleum tank WATER SAMPLE RESULTS: Coliform ~,'A~'/.5~','~ ,-~"-"/ Dateo samp e: Nitrate '~" ~ Other bacteria Collected by: P/'~J: c~O'~$6~6T~ B. SEPTIC/HOLDING TANK DATA Date installed /,$- /25- ~' ,~ Tank size Cleanouts (Y/N) I~ Foundation cleanout (Y/N) High water alarm (Y/N) /~/,Ar Date of pumping /~J-~. ) Compartments Depression (Y/N) Alarm tested (Y/N) Pumper / Well(s) On lot [[0 On adjacent lots To property line 4,~ / Absorption field Sudacewater/drainage '~/ /-7o ~,/q'~'" SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: · lob q- 4 Foundation Water main/service line 72~o26 (3/93)* Front CONTINUED ON BACK PAGE Vent (Y/N) "P p on" level at "~ump off Level at High water alarm level /p °n"lev /testi'~ump ~t/ Ivteets MOA electrica~/c~es (Y/N) ..... / / Well on lot__// On adja~c'ent lots S, Edace water D. ABSORPTION FIELD DATA Date installed lQ-//S ~- ?~--u~ I...ength ~ ~L - ~' Wi~h ~ 0 Total abso~tion area ~ ~ ~ C)ate of adequacy test ~ ~ ~ Water level in abso~tion lield before test Peroxide treatment (past ~ 2 months) (Y/N) Soil rating (GPD/FF) ~/ Gravel thickness Cleanout present (Y/N) Results (pass/fail) System type /~-~ 5 yS/'~W~-~ __ _Total depth / -~" ~__ Depression overfield (Y/N) /~ .. ~_~.~ for ._~ Bedrooms After test ~,-~-.~ If yes, give date /~///~- SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot / ~ % To building foundation On adjacent lots 50 Sudace water Curtain drain ~ On adjacent lots /~ / Property line ~-~ To existing or abandoned system on lot Cutbank ~ ,/A- Water main/service line / Driveway, parking/vehicle storage area E. ENGINEER'S CERTIFICATION I certify that I have checked, vedfied, or conformed to all MOA and HAA guidelines Signature ~ ~'~ Engineer's Name Date /~- ~ / HAA Fee $ ~'-~' C'O D ..eof Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number ~ COMMERCIAL TESTING & ENGINEERING CCI. ,a~;I~E~,*~.______~L L^aO,^TOP,',' Sample Reme~ ROUTINE SAI~PLE CO[JLEc-i~D BY~ UA. Order ~72837 Report Co~eted ~H,/10/9~ ~lle~ed ~11/03/93 ~ 11:40 hrs, Recelv~ =11/03/9~ % 13:00 hfs, ~t~1 Dl~ctor~S~ ~. ~ Allmmble EXt, Anal P~re~eter Results 0ual Units liethod Lilnlta Date Oate Init Nitrate-N 0.39 i~/L gPA 8§3,2/300,0 10 1.1/0.5 CHR * see Special Ins'tz~eklons Above UA - Unavailable ** See 8e~ple Remarka ~w NA = Hut ~yz~ O = ~deteet~, Re~r'L~ value is the pra~lc~ ~tiflmtion limit. LT = ~sa 'l~ D = ~C~ dllutl~, ~. Greater ENVII:IONNIENTAL 8ER¥1CE;B IN ALASKA, COLOHA'~O, UTAH. ILLINOI.,9,, OI IIO, MAI~¥LANI), WIST VIFI~INIA, NF--W JERS£¥, 5OI,/11t CAROLINA SENT BY:S1X~A ESCROW D[2=q'. ; 3-13-8§ ; 1§:48 ;STEWtfl~T TII'/.J~ ESCROW-, MUNICIPALITY OF ANCHORAGE I DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 90734~4786;# 2/ 3 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # 1. GENERAL INFORMATION Complete legal description HAA # ,~/~ fl5 O'7eO e Location [site address or directions) _~,~_~io,~ '~.~ t .... .~*-o~t. c~..- ....... Prope,yowner ~C~ ~So~ ~ Dayphone~. Lending agency .~6n~ ~[b ~C,~ Oayphon.~~_.. Mailing address Unl~= othe~ise requestS, HAA will be held ~or pickup. NUBBER OF BEDROOBS: TYPE OF WATER SUPPLY: I ndividual well Community well Publio water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DIgPOSAL: Individual on-site Holding tank Commu nity on-site Public sewer DEC 2 2 199 Municipalily Gl Anotlorage DepL Health & Human Services NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-~lilRev, 1/gl) Front MOA~I SESNT BY:STCA ESCROW DEIST. ; 3-13-8§ ; 1§:§0 ;STI~WART TITU~ ESC~OW-~ 80754,_,q478(~;# 3/ 3 STATEMENT OF IIt.:"j.~cnoN ey NO,NF.,m Am certifla<l by my seal affixed hereto and am of the validation date ahown below, { verify that my {nvastigat{on of this Health Authority Approval application mhow~ that the on-site water supply and/or westewater dJiposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated lmmin, i further verify that based on the information obtained from the Municipality of Anchorage files ancl from my investigation and inapection, the on-aite water supply and/or waatewater diq3oaal system Is in compliance with all Municipal and State cocfes. ordinancea, and regulatiorm in effeat on the date of this Inspection. Address ~ Engineer's signature ~ Date .. / ;Z.~,,2 /- ~7~ ~, The Municipality of Anohorago Depadment of HeaJth and Human Servk~m (DHHS) if~ues Hoalth Auihority ApproveJ Ce~ifloates beeecionly upon the reprogantetiOne gl .v~n in paragraph 5 above by an Independent Prof'~- ~ ~-b~al ,e,~Igineer regiMered.in the State of ~ The DHHS does this as a ~oun'esy tO purchasers of homes · and their lending Inat~tution~ in orderto estbr~y e,m~ln fedand and state requimmant~. Employees of DHHS do not conduct inspections or analyze data before a omrtiflcate is iasued. The Munlr. Jpality of Anchorage is not remponmible fur errore or omimsiorm In the p~onaJ engiflesf% wm'k. MUNICIPALITY OF ANCHORAGE Department of Health & Human Services DIVISION OF ENVIRONMENTAL SERVICES 343-4744 Parcel I.D. # CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Descril~'t[~n (include 10t, block, subdivision, section, township, range) Lot .~ Ra~om Ridge Location (address or directions) 16801 Ransom Ridge Road (b) Property owner Mailing Address (c) Lending Institution Freddie Mae ~36-275180-3 Te, lephone: (home) Business Telephone Mailing Address (d) Real Estate company and Agent Address 3201 C Street, Telephone 563-5500 Jack WhJ~ Company Suite 100, Anchorage, ATTN~ KrZs K~rt2 Alaska 99503 (e) Mail the HAA to the following address: (or check herej~ if hold for pick up.) List contact person and day phone number below: S & S ENGINEERING Eagle River, Alaska 99577 2. TYPE OF RESIDENCE Single-Family J~ Number of bedrooms 3. WATER SUPPLY Individual Well ~ Community [] Public [] Note: If community well syst.em, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-siteJ~ Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (Rev. 7/88) Page 1 of 2 Address _ Date 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION. As certified by my seal affixed hereto and as of the validation date shown below, I verify that my invest gation of th~ Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functiona .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Telephone r'~ ¢¢"' ~-~ '~ ~ F. agie River, Alaska 99.577 6. DHHS APPROVAL b Approve~ for ~ e~rooms Aipprove~' '~ Disappro~'ed Conditional Terms of Conditional Approval Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions · k in the professional eng neer s wor . 72-025 (Rev. 7/88)Back Page 2 of 2 A. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) MU N ;HeaRh' .~ th'~l~,~ ~ roval (HAA) ~NVt~ONI~HEI~tl¢~II~¢I:~ I~BEI~U,ARY 1984 343-4744 F'E~ 2 ~9,r;j0 Legal Description: RECEIVED If A, B, C, D.E.c. Approved (Y/N) ~/~/ Yield--/"/.(o ,~Z) AA . ) Well Classification Well Log Present (Y/N) ~ Date Completed Total Depth ~_-~ ? Cased to ..~0 ~"~ DePth of Grouting Static Water Level ~ t Casing Height Above Ground ,/ Electrical Wiring in Conduit (Y/N) I-1 SEPARATION DISTANCES FROM WELL: / To Septic/Holding Tank on Lot Pump Set At o !.4~' Sanitary Seal on Casing (Y/N) ~ Depression Around Wellhead (Y/N) A~ ;on Adjoining Lots / O0 To Nearest Edge of Absorption F~jl~ Lot q~'/ '")(- ; On Adjoining Lots /CO'C- To Nearest Public Sewer Line ~ To Nearest Public Sewer Cleanout/Manhole ! To Nearest sewer Service Line on Lot ~7 ~'~- t- Water Sample Collected by ~ ~ .~----~/'d~)~JC~d'41"t~/ ;Date ~J~A~uf~'~ Water Sample Test Results ~h:S '~-D~ ~ /~,,~ %~r]"'~!,% ~ Comments ; fo B. SEPTIC/HOLDING TANK DATA Date Installed ~,~.~_~ Size Standpipes (Y/N) Depression over Tank (Y/N) Pumping/Maintenance Contact on File (Y/N) Holding Tank High-Water Alarm (Y/N) SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: t OOO No. of compartments Air-tight Caps (Y/N) ~ Foundation Cleanout (Y/N) ~ ' Date Last Pumped ! -- & I -- ~0 :for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field TO Water-Supply Well ' ( O0 To, Property Line .~o ~- To Water M~in/Service Line (o0 ' ~ To Stream, Pond, Lake cC:Major Drainage Course 72-026 (Rev. 7/88) Front Page 1 of 2 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed .... ! ~ - ~ -- Width of Field I ~, / Square Feet of Absortion Area Depression over Field (Y/N) Results of Last Adequacy Test Type of System Design Length of Field _~ 6 Depth of Field -~ Gravel Bed Thickness / Statndpipes Present (Y/N) Date of Last Adequacy Test SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water-Supply Well To Building Foundation Lot To Water Main/Service Line ./(,, ' "P 1'o Stream, Pond, Lake, or Major Drainage Course ~- To Driveway, Parking Area, or Vehicle Storage Area Comments ~. ~¢ ~'~C~q/vx ~ ~ D. LIFT STATION Date Installed % Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Meets MOA Electrical Codes (Y/N) Comments __ To Property Line To Existing or Abandoned System on ; On Adjoining Lots z,O To Cutback (if present) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. **Check Permitted Bedroom Rating Against HAA Request** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect inspection. Signed $ & $ ENGINEERING 17034 Eagle River Loop Road No. 204 Cornpany ........ ~s,,,,k~, 99577 Receipt No. Date of Payment Amount: $ 72-026 (Rev. 7/88) Back Receipt No. Waiver Fee: $ Date of Payment Page 2 of 2 ~,:~,,7_~l~.the date of this CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. ~~','~ 5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343 ~'L~.'O;;.~.',E;'% FEDERAL TAX ID # 92-0040440 ANALYSIS REPORT BY SAMPLE £or Wo=k Orde~ # 19478 Date Report Printed: JAN 29 90 @ 15:32 Client Sample ID:L2A RAMSON RIDGE PWSID :UA Collected JAN 23 90 @ 14:30 hrs. Received JAN 24 90 @ 16:40 hrs. P~esezved with :AS REQUIRED Client Name : S & S ZNGR Client Acct : SNSENGP P.O.# NONE RECEIVED Req # O~dered By : BOB SCHAFER Analysis Completed :JAN 26 90 Send Reports to: Laboratory SupezyL~o~/:STEPNEN C. EDE i)S & S ENGR Released By :~~_ ~_// Special Instruct: Chemlab Ref #: 9306 Lab Smpl ID: 7 'Matrix: WATER Allowable Parameter Tested Result Units Method Limits NITRATE-N 0.47 mg/1 EPA 353.2 10 Sample ROUTINg SAMPLE Remarks: SAMPLE COLLECTED BY R.P. 1 Tests Performed * See Special Instzuctions Above UA-Unavailable ND= Hone Detected ** See Sample Remazks Above NA~ Not Analyzed LT=Lees Than, GT~Greater Than MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES DIVISION OF ENVIRONMENTAL SERVICES CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4744 Application Date GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL) (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 2A Ransom Ridge Subdivision - Ti1N R3W Section 3 Location (address or directions) 16801 Ranson Ridge Road~ Anchorage (b) Property Owner Michael Buckner Telephone: Home 24320440 Business 564-0667 Mailing Address (c) Lending institution Mailing Address (d) Real Estate Company and Agent Address 16801 Ransom Ridge Drive, Anchorage Centrust Mortgage Corp. Telephone 561-4930 4000 01d Seward Highway, Suite 103, Anchorage, Alaska 99503 Telephone (e) Mail the HAA to the followina address: or: Check here E~, if hold for pick up. List contact person and day phone number below. Martha Buckner - 243-0440 TYPE OF RESIDENCE Single-Family E~ Number of Bedrooms three(3) WATER SUPPLY Individual Well [~x Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite ~xx Public [] Community [] Holding Tank [] Note: If corn munity welt system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 fRev 8/861 Front ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Hearth Authority Approval shows that the on-site water suppry and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water suppry and/or wastewater disposal system is in compliance with afl Municipal and State codes, ordinances, and regurations in effect on the date of this inspection. Name of Firm Telephone Address Date Engineer's Seal This department has received written confirmation from the engineer regarding the Conditional Approval of December 16, 1986. The corrections have been accomplished and an inspection has been completed by the engineer. The subject property meets with Municipal standards and is now approved. See letter dated February 2, 1987. DHHS APPROVAL Approved for three(3) bedrooms by ~ /~' ~,~ Approved XXXXXXXYD~XX Disapproved Conditional Terms of Conditional Approval Date February 3, 1987 CAUTION The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their Pending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 fRev 8/86) Back /vlunicip '.,ty of Ar ¢hor e P.O. 196650 ANCHORAGE, ALASKA 99519-6650 1907) 264-41~ TONY KNOWLES, MAYOR DEPARTMENT OF HEALTH & HUMAN SERVICES February 2, 1987 Michael Buchner 16801 Ransom Ridge Anchorage, Alaska 99516 Subject: Lot 2A Ransom Ridge Subdivision, Approval of Subdrain Dear Mr. Buchner: A subdrain was constructed on the subject property as a condition of the Health Authority Approval issued on December reviewed and approved. This installation meets the conditions of the Health Authority Approval issued by this Department on December 16, 1986. sincerely, .~. --'~/,~.,~ Stephen S. Morris civil Engineer On-site Services CC Centrust Mortgage Corp. 4000 Old Seward Highway, Suite 103 Anchorage, 99503 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES H 8 6-1 3 3 7 DIVISION OF ENVIRONMENTAL SERVICES CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4744 Application Date GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL) (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 2A Ransom Ridge Subdivision - TllN R3W Section 3 Location (address or directions) 16801 RAnsom Ridge Road, Anchorage Property Owner Michael Buckner Telephone~ Home 243-0440 Business 564-0667 Mai~ing Address 16801 Ransom Ridge Anchorage Lending Institution Centrust Telephone 561-493D Mailing Address 4000 Old Suite 103, Anchorage 99503 Real Estate Company and Agent Address (b) Drive, (c) Mortgage Corp. Seward Highway, (d) None (e) Telephone Mail the HAA to the followina address: or: Check here ~ if hold for pick up. List contact person and day phone number below. Martha Buckner, 243-0440 2. TYPE OF RESIDENCE Single-Family F"2 x x Number of Bedrooms three ( 3 ) WATER SUPPLY Individual Well:l~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite [~:X~ublic [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (Rev 8/86) Front 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Constructinq Engineers, InC.Telephone 694-9098 Address 9601 Buddy Werner Drive, Anchorage, Alaska 99516 Date Engineer's Seal DHHSAPPROVAL / ~'~,bedroomsby~~' ~~ Date December 16, 1986 Approved for , ', ~. Approved ~ , Disapproved Conditional, ~ Terms of Conditional Approval. ~~ ~ ~ ~~ ~~'~ ~/~ /~ CAUTION The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-0~$ CRev 8/86~ Back MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES DIVISION OF ENVIRONMENTAL SERVICES OF ON-SITE SEWER AND WATER FACILITY 264-4744 Application Date 1. GENERAL INFORM~ATION (MUST BE COMPLETED PRIOR TO SUBMITTAL) ~'~--~'/ (a) Legal Description (include lot, block, subdivision~c~, township, range) Location (address or directions) (b) Properly Owner ~.~.~ ~',..~ Telephone: Home~-O~O Business ~'G~- O~E (c) Lending lnstitution ~T...+ ~?~ ~p, Telephone .~(- (d) Real Estate Company and Agent ~ (O ~ {~ ~ Address (e) Telephone Mail the HAA to the followina address: or: Check here ,~"hold for pick up. List contact person and day phone number below. WATER SUPPLY Individual Well [[~"/'Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Enwronmental Conservation attesting to the legality and status. SEWAG_.E.~POSAL Onsite L.~ Public [] Community [] Holding Tank r'l Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page t of 2 72-025 fRev 8/86~ Front ~.' ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and Stpte codes, ordinances, and regulations in effect on the date of this inspection) .~-~ (--~ ~ ~ r~.~,- ~ ~~ NameofFirm ~0~ ~~ ~ Telephone DHHS APPROVAL" /,.. Approved for ~/~,'~ Approved ":,bedr°°ms by ~ ''~' Disapproved Terms of Conditional Approval "~'~ Date / 2.- -/~'- ~' Conditional CAUTION The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (Rev 8/86) Back WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Descdption: ¢ Well Classification ~ If A, B, C, D.E.C. Approved (Y/N) Well Log Present (Y/N) y Date Completed ! 7,.. -- ~' '~ yield Total Depth 'Z.. ~ 1.~ Cased to 'Z-O Depth of Grouting ~ Static Water Level '~.~--'~ ' Pump Set At '7~'7~.~- Casing Height Above Ground ~ ! 7_. I~ Electrical Wiring in Conduit (Y/N) Y Separation Distances from Well: To Septic/Holding Tank on Lot "{- /' O O To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line '~ / 4~" Cleanout/Manhole -f- ! ~ 0 ¢ Water Sample Collected by ~' ~'~'~" Water Sample Test Results Comments '-~ ~ ~= Sanitary Seal on Casing (Y/N) Y Depression Around Wellhead (Y/N) ~ ; On Adjoining Lots ¥ ; On Adjoining Lots To Nearest Public Sewer ,-'c ¢ To Nearest Sewer Service Line on Lot ;Date B. SEPTIC/HOLDING TANK DATA Date installed Standpipes (Y/N) Y AirBht Caps (Y/N) Depression over Tank (Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) ,AM/,o/. Separation Distances from Septic/Holding Tank: To Water-Supply Well '~ / C) ~:) f To Property Line ~'-,~ O '~ To Water Main/Service Line ~¢- -~''~ Course 5' ~'~ /'~ ~/'"'",~- (.7./-.~'-..~ / ~ -- ~'"';'~ Size ,/~ No. of Compartments Foundation Cleanout (Y/N) Y Date Last Pumped ~ 'Z.. --~- ; for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field ~--" To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field / Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well To Building Foundation /,-~-' To Water Main/Service Line 7~' To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Type of System Design Length of Field Depth of Field Gravel Bed Thickness Standpipes Present (Y/N) Date of Last Adequacy Test TO Property Line 't/--- ~.~0 To Existing or Abandoned System on ; On Adjoining Lots .-J.. ,~ To Cutbank (if present) Comments D. LIFT STATION Size in Gallons % "Pump On" Level at ~ High Water Alarm Level at Tested for Electrical Codes (Y/N) Comments ~- Dimensions Manhole/Access (Y/N} .~' "Pump Off" Level at _ ~'~"~ ~_.--~'- ~ring Adequacy Test Meets MOA ** Check Permitted Bedroom Rating Against HAA Request ** I certify t t-~l~t I I;i~e~¢qked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection) Signed~'~~¥/'~//'/~/-~ Date i~"--I'"/"---~'(c=, ~+ ~r ~~ Company ~SC ~ ~OA NO. 2~ ~ -0 ~ (~'V. "~*~:'~'" Receipt No.~¢ C~ / '- OC~ 0 ~ Date of Payment Amount: $ Page 2 of 2 72-026 (11/84) MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL PROTECTION P.O. BOX 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES December 15,1986 Hank Wilson, P.E. Constructing Engineers, Inc. 9601 Buddy Werner Drive Anchorage, Alaska 99516 Subject: Lot 2A, Ransom Ridge Subdivision Waiver Request WR86-170 Dear Mr. Wilson: Your request for a waiver of the 100 foot separation distance required between the septic system absorption bed and well on the subject property has been granted. This distance has been waived to the existing 95 foot separation. You have noted that the septic system is located within 100 feet of a platted creek maintenance easement. This appears to be a minor drainage that may or may not be considered a "surface water" as defined by the State Department of Environmental Conservation, "Surface waters" require a 100 foot setback to septic systems. This Department is unwilling and unable to make a determination of the status of this drainage in terms of its status as a "surface water" given the brief period of observation and the current unseasonally warm weather conditions. The purchaser of this property, Michael Buckner has requested a conditional Health Authority Approval for the subject property. He has agreed to escrow funds to construct a subdrain system to collect and carry any surface water in solid culvert past his septic system thus mitigating any problems with surface water setbacks. Plans for such a system havebeen reviewed and approved in concept by this Department. A conditional Health Authority Approval will be issued under the provision that funds be escrowed to cover the cost of this subdrain system. It should be noted that it is possible that this drainage will not be considered a "surface water" after further observation and will therefore not require the construction of the subdrain. This determination can be made early in the summer by this Department. If this drainage is in fact classified as a surface water requiring 100 foot setbacks, construction of the subdrain must be completed no later than July 15, 1987. Sincerely, · Morris Civil Engineer On-sit~ Sevices HENRY WILSON g601 BUDDY WERNER DR.: ANCHORAGE, AK ggSI6 (gO7) 346-2000 En iineers, Inc CHARLES A. LANDERS SR BOX Ig2-A, MYRTLE DR. EAGLE RIVER, AK gg577 (907) 694-90g~ December 12, 1986 Steve Morris, civil Engineer ~unicipality of Anchorage ' Dept. of ~ealth & ~iuman Services P. O. Box 6650 Anchorage, AK 99502-0650 Re: Lot 2A, Ransom Rid. ge, Sec 3, TllN, R3W, S.M. Request of Waiver of Separation from well to bed of 95' and conditional ~AA pending sub- drain improvement in nearby minor drainage course. Dear Mr. ~rris: ~e request a formal waiver of the 95' separation from well to seepage bed that was noted and informally granted on the ~Q~ work- sheet of ~arch 6, 1984 by JLT Engineering. As noted at that time, the well is significantly upslope of the seepage bed (see contour map ill subdivision file). Additionally, the 5' less horizontal separation would have no practical effect in preventing contamina- tion of the well. The subdivision plat shows a drainage easement and calls out 100' setback from the thread of the easement to any portion of any septic system. Entire subject system is within the 100' setback and was in place when the plat was filed. You have advised me that during recent improvements to Golden View Drive that subject drainage was directed to a culvert some dis- tance north of subject property. Due to an unseasonal thaw that has occurred this week, we cannot tell at this time if any of the flowage has escaped the roadway diversion. HENRY WILSON 96OI BUDDY WERNER DR.: ANCHORAGE, AK 99516 (DO7) 346-]000 ineers, Inc En )rs CHARLES A. LANDERS SR BOX 19~'-A, MYRTLE DR. EAGLE RIVER, AK 99.5?7 (gO7) 694-9098 ~.~r. Steve Morris Re: Lot 2A, Ransom Ridge Page 2 We request conditional HAA be given until June 15, 1987, based on the property purchaser agreeing that a private engineer and a member of your staff inspect the property around June 1, 1987, and that if significant seepage is present in the old drainage course at that inspection, the property owner will cause to have installed a subdrain system approved by the Health Department to correct any shortcomings observed. Upon completion and Itealth Department approval of subject system, permanent }L~A will be issued. A conceptual plan of the subdrain system is transmitted herewith. Please contact Chuck Landers of our office at 694-9098 if any further assistance is required of us. Sincerely, CONSTRUCTING Henry H. Enclosure APPUCA~O~ ~0~ ~LTH ~HO~TY ~PP~ov~n ~T~T~ 1. General Information Application Date (a) Legal Des~iDtion ( include, lot, block, ~subdivision, section, township ~ range ) Location (address or directions) Address ,(e) Rmal Estate Co. & Agent Address Te le phone 2. Type of N~sidence Single-Family ~ Number of Bedrcx~ms 3. W~ter Supply Individual Well Multi-Family Other (describe} Note: If ~,~i:~nity ~11 system, must t%mve written confirmation frcm the State Depar~nt of Enviropm~ntat Conservation attesting to th~ legality and status. Is the ~11 adequate fo~ the number of bedromns specified in this ?I~A (Y/N) 4. Se~.~e Dis~3sal' Onsite ~. Pdblic ~--~ Co~,~nity ~-~ Holding Tank ~-] Is the wastewater disposal system adequate for the number of ~drocms .(.Y/~q) [Page 1 of 2] 2-15-84 .Engineering Firm Providing. Inspections ~ Tests, Data and Information ?. I certify that I have checked, verified, c~ conformed to all MOA HAA Guidelines in effect on the date of this inspection. Date ( ENGINEER SEAL) Telephone q 6. DH~ .Approval Approved fo~ Approved ~ Terms of Conditional Approval Disapproval ~-] The Municipality of Anchorage Eepaztment of Health and Envirol~rentat Protection does not guarantee the continued satisfactory perfc~nnance of the wate~ supply and/or the waste,water disposal system. This approval indicates that, as cf the %~aiidati©n date sho~nn above, based on the. data and information furnished ~! an entire, er registered in the State of Alaska, the water supply and wastewater disposal system is safe and func- ticna! for t_he numbe~ of b.:dn-oc~ and type of structure irldicated. ( DHEP SEAL) 7. Mail t2~e [*SAA to the following address: KB2/d5/s [Page 2 of 2] '~UN~CI~ALITY OF ANCHORAGE DEPT. OF HEALTH ENVIRONMENTAl. PROTECTIOI~ MAR 6 MUNICIPALITY OF B/qCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST m FEBRUARY 1984 Well Classification ~p,' U,~ 7"',e_. Well Log Present (Y/N) y Total Depth ~ ~ ~ . .. Cased to Static Water Level ~ ~ 7 Casing Height Above Ground , , ,/,~ '~ Elect/~ical Wiring in Conduit (Y/N) ~ Separation Distances f~c~ Well: To Septic/Holding Tank. on Lot /~6~ / 7"" To Nearest Edge of Absorption Field on Lot To Nearest Public Se~er Line /~.//% If A, B, or C, D.E.C. Approved(Y/N) Date Co~leted Pu p set ?3- ' ; On AdjoiniJg Lots ?~0 '7~ .... ; On Adjoining Lots /~ '~ To Nearest Public Sewer Cleanout/Manhole /~///~ To Nearest Sewe= Service Line on Lot water San~Dle Collected By ,'~e~ ,~,, 7-J(~,,~/)e ; 'Date 3f - ~ ^ ~/ Wate~ Sample Test R~sults ~ ~ B. SEPTIC/HOLDING TANK DATA Date Installed / f -f -~ Size ] ~90 ~3 __ No. of C~3artments Standpipes (Y/N) ~ Air-tight Caps (Y./N) ~ Foundation Cleanout (Y/N) Depression ove~ Tank (Y/N) /%/' Date Last Pumped Pumping/Maintenance Contract on File (Y/N)7~/ ; for. Holding Tank High-Wate= Alarm (Y/N) /~]/~ , , Tempora~y Hold~ing Tank Permit (Y/N) Separation Distances frc~ Septic/Holding Tank: ! To water-Supply Well ___~{Pcp ' ~' TO Property Line . :>'-~' --~- To Wa~cer-?~i~/Service Line ___~a~ ~ Course /~ /A~ To Building Foundation /~ ! To Disposal Field ~ _% To Stream, Pond, Lake, or Major D~ainage Continents [Page. ! of 2] 2-15-84 C. ABSORPTION FIELD DATA De Soils Rating in Absorption Strata Date Installed / E- ~- ~-~ Width of Field /8' . . Square Feet of Absc~ption A~ea Depression over Field {..Y/N) Results of Last ~equacy Test f~- ~/~/~R Type of System Design Length of Field Depth of Field Gravel Bed Thickness / Standpipes P~esent (Y/N) Date of Last Adequacy Test Separation Distance f~cm Absorp%~qn Field: 5-~j~~'<~,~ To To Water-Supply Well ~ ~ ~_~. ~o~ty Li~~ ~ To Building Foun~tion ~--'~'. To Existing ~ ~ndo~d Sys~m ~ Lot. ~/~ ; ~ ~joining ~ts /~ ~ ~ To ~/~vi~ Li~ f~ ~ To ~t~(if ~e~nt) ~/~ To St~e~ond~ke/~ ~jo~ ~aina~ C~se To ~i~way, Pa~king ~ea, ~ Vehicle St~a~ ~ea /~ ' ~e~d~e~ LI~ ST~TI~ Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested fo~ Electrical Codes (Y/N) DimeD~ions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles du~ing Adequacy Test. ~ets MOA C~-~¥~ents ** Check Permitted Bed~ocm Rating Against HAA Request I certify that I have checked, verified, c~ confc~mad to all MOA HAA Guidelines in effect on the date of this inspection. ~!ii' KB1/d5/s [Page 2 of 2] MOA No. 2-15-84