HomeMy WebLinkAboutRASMUS LT 2
He~ h and Environmental Prote ion
~' ~ Fourth Floor West
825 L Street
Anchorage, Alaska 99501
279-2511, x 224, 225
LOCATIONi
:. SEPTIC TAN~:
DISTANCE
F;ROM WEEL
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LEGAL DESCRIPTION~ /_S~. ? P/~'~_"~
NUMBER OF
COMPARTMENTS__-
li~SIDE LENGTH ................ INSIDE W DTH ...... LIQUID DEPTH .... LIQDID CAPACITY_ ALLONS
TILE DRAIN FIELD:
, i t
__(.~.) __ FOUNDATION__/~_
D 9TANCE [:ROM WELL
· ABSORPTION AREA _~¢"~1 SQ. I T, LENGYH OF EACH LINE .....
t DEPTII OF FILTER
DEPTH: TOP OF TILE TO FINISH GRADE_. ~ MATERIAL BENEATH TILE ABOVE
/~ / TOTAL LENGTH,,~} j
___NEAREST LOT LINE_' .... ~ ......... OF LINE ___ ~_~/
TOTAL EFFECTIVE
TILE .__..~/_______ I N,
SEEPAGE PIT:
DIAMETER .... OR WlDTtt __, EENGTH , DEPTH
Log Crib Rings Crib Size: DIAMEI'ER .... DEPTH ..... DISTANCE FROM:
.... I-OTAL EFEECTIVE
BUILDING FOUNDATION____
WELL .............
NEAREST LOT LINE .... ABSORPTION AREA (WALL AREA) ______SQ. FT.
Class:_ ( Depth:
Well Distance To: Lot Line __
B!dg:, Sewer Line:
Pipe'Mate~ials:
# of BedrOoms: ~-
Installer~
Remarks:
2_'0000 SC.,_IRF.:E FEET
T'¢PE OF SOIL flBSOF.'ETION "_-]'¢STEM IS: TRENCH
', .... II, 4 SOIL RRTING (SO. FT',-'"BR)=
I1R,:sIM_M NUMBER OF BEDROOMS ,~
THE REQUIRED _,I,:::E OF THE ..... ~ .... '
THE LENGTH DIMENSION IS THE LENGTH (IN FEE7') OF THE TRENCH OR DRRINFiEL.[.".
THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFFICE OF THE
GROUND RND THE 8OTTOM OF THE E,'-'<CRVRTION (IN FEET).
THER. E IS NO SET WIDTH FOR TRENCHES. ''F'"
TFIE GRRVEL BEFTH IS THE MINIMUM DEPTH OF GRR',/EL BETNEEN THE OUTFFII_L
RND THE BOTTOM OF THE E~<CRVRT[ON (IN FEET).
BRCKFILLING OF 8NY S~¢S'f'EM WITHOUT FINRL INSPECTION 8ND RPPROVRL
DEF'RRTMENT HILL BE SUBJECT TO PROSECUTION.
MINIMUB1 DISTflNCE BETWEEN fl WELL fiND tiNY ON-SITE SEWRGE DISF"OSRL. S'T'S'TEId IS
t80 FEET FOR R PRIVRTE WELL.OR 28¢ FEET FOR R PUBLIC HELL
SPECIF'ICRTIONS RND CONSTRUCTION DIRGRRMS RRE RVRILRBLE TO INSURE PROPER
INSTRLLRTI ON.
I _.ERTIF¢ THfiT
r ,-" ~- ="=
2L: I RN FFtMILIRR WITFI THE REg!UIREMENTS FOR JN---,z FE _-,ELIER_, AND HELLS AS SET
FORTH B'? THE flUNI-.IPHLIT~r OF RNr:HAF.'RGE.
2: I HILL INSTRLL THE S~'STEM IN ACCORDANCE WITH THE CODES.
3: ! UNDERSTAND THRT THE ON-SITE SEWER _,r~TEI1 MR'¢ REQUIRE ENLRRGEMENT .T.F' THE
RESIDENCE IS REMODELED TO INCLUDE MOR. E THAN 4 BEDROOMS..-"
/ ..: : , , /'
NT ,.ji~RD'¢S KOUTCHRK
,=~ ., , , '.~.. ~' . /~4 ~ , ~ ....... DFITE .......... ~Z ......
Hea..~. and Environmental Prote,~,,/ion
Fourth Floor West
825 L Street
Anchorage, Alaska 99501
264-4720
............ i-~I-~CTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION __ LEGAL DESCR PT ON
SEPTIC TANK:
DISTANCE
FP, OM WELL_
INbIDE LENGTH___
MANUFACTURER
INSIDE WIDTH__
MATERIAL
LIQUID DEPTH
NUMBER OF
COMPARTMENTS
LIQUID CAPACITY . GALLONS.
TILE DRAIN FIELD: ~
DISFANCE FROM WELL ....... FOUNDATION
NEAREST LOt LINE
TOTAL LENGTH . , /
__OF 'LINE
# of Lines DISTANCE BETWEEN LINES ..... TRENCH WIDTH___ IN. TOTAL EFFECTIVE
/'d3SORPT ON AREA __%~"~'~(~ SQ, FT. LENGTH OF EAGt LINE
DEPTH OF FILTER
~ ':P""- TOP OF fILE 10 t-INISII GRADE MATERIAL BENEATH TIt_E IN, ABOVE TILE IN.
SEEPAGE PIT:
DIAMETER --
OR WIDTH LENG'FH DEPTH
Crib Size: DIAMETER .... DEP¥1;.__ DISTANCE FROM:
TOTAL EFFECTIVE
Log Crib Rings__
8UILDIIK~ FOUNDA-IION ....... NEAREST LOT LINE
WELL
ABSORPTION AREA (WALL AREA)
SQ. FT.
ell
lass: Depth:
ell Distance To: Lot Line
ldg: Sewer Line:
ipe Materials:
of Bedroomsm
nstaller: ~
emarks: ~
'i-HE OiT;f:q'i{ OF' t3 'f'f;lff_;NCi'i (.}¢;-'. F')'T :i'S THE [.':-'~;STFii',ICEi E~!E"i'HE~i'q THE
THERE ;i;'.:~; h.'-'O :3~'7~" i.4iii:,T.H FO?.
E~NE:, THE E~O"f'TOi"i EIF THE; E;,4CRUFff';[ON (:[~'4
GrEATEr ANCHORAGE ArEA BorOUGh
DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO.
33~o "c" STREET ANCHORAG£, ALASKA 99503
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
NAME OF APPLICANT ~/~/~ ~'~ ~
INSTALLATION LOCATION ~;~ /~/~' ~ ~
LEgal DESCRIPTION ~0 ~ ~ ~ ~
INSTALLATION OF: SEPTIC TANK SEEPAGE PiT
TYPE AND SIZE OF FACIL'TY TO ~E SERVED ~ ~ ~ ~ ~;~
FINANCED THROUGH
SOil TEST RESULTS
COMPLETION DATE ANTICIPATED
, DRAIN FIELD ~ OTHER
TO be INSTALLED BY ~
NOTE; THIS PERMIT IS NOT VALID WITHOUT SOIL T~SI
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE /,~F~ ~] 9,/~[~.~ TYPE
MINIMUM DISTANCES, REQUIREMENTS ~*~"~ l~5'/-~A//~
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT DRAIN FIELD
SEPTIC TANK TO SEEPAGE PiT WALL
SEPTIC TANK ., SEEPAGE PIT
TO NEAREST LOT LINE.
DRAIN FIELD
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
SEPTIC TANK, , SEEPAGE PIT
TO RIVER, LAKE. STREAM.
DRAIN FIELD
/20 /
SEEPAGE PiT
ALSO CONSIDER AREA WELLS.
SEEPAGE PiT
DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIO TANK AND SEEPAGE PIT
F~TTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING ~NSTALLATiON.
SEEPAGE AREA SIZE
TYPE
DIAGRAM OF SYSTEM
[ CERTIFY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREAT_E*~. ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
D ESGRIEIED SYSTEM,: IS IN ACCORDANCE WITH SAID CODE. (////~.,~. ~~//~:,/~
............. V"---/ /'-
GREATER ANCtlORAGL Al(LA bOROXO~h
Department of EnvironmenLa] Qua]it.y
3330 "C' Street,
Anchorage, Alaska 99603
SOH,S.I,OG - I)EROI,ATION TI~'S'F
Performed for Gladys Koutchak Date Performed.._..~_0_/_l~.3/?_~_5
Legal Description: Sou~h 260' Lot 77 Sec. 9 T12H R3W - 8'7-2~¢ T,ake Ot±s
This form reports: ~-~i-j-s~Tl0'g .. Yes Percolation test
Feet ..... Or '.~ics-.~ ....................
i
~-,, ~^,a,-14~, ~41~ ' ,,.
2-
Dry Medium Grey well graded
Gravel (GW)
85,::S.F./B. R.
10-
ll -
]2 - Bottom of Test Pit
13-
14-
Was ground water encountered?
No
.L -
,,,,%
If yes, at what depth?
Reading
Date
Gross Time
Net Urop
~-r~olation rate lalnute.;. ¥~.q -- Drain Field ........
August 29~ 1977
Gladys Koutchak
~729 Lake otis
Anchorage, Alaska 99502
S,abject: Lot 2 Sectxon 9 -~12N R3W P~smus Sub~ivision
~ th~
was conducted bY this~department upo~
2tn adequacy test ' · · c
inaividuat sewer facilities at the abov~ubject property.
This test revealed the system to be perform~n~ at one~hal~
(%) its acceptable rate. Therefore~ an upgrade will be
necessary before this depart~nt c~ approve the present
A total of 170 square feet of absorption area needs to
be adaed. This can be accomplished by a trench ten(10)fe~t
deep with five(5) feet of gravel backfill seventeen(17) feet
~--~ng. A pe~it must be obtained from this office before any
upgrade is b~n. Please bring this letter with
If there are ~Y further qaestions, please contact this
office at 264-4720.
Sincerely~
Co~y Willis~
Sanitar~