Loading...
HomeMy WebLinkAboutROSEBUD HILLS BLK 1 LT 7 " Municipality of Anchorage Page I of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SC',-' p7OO ~$' PIDNumber: O/ 7'~,~!3 ~ Name: ~7 ~ Wastewater System: ~ New D Upgrade Address: /z~o~ ~ n~ ~ ~, ~ ~e~/~ ABSORPTION FIELD No. of Bedrooms: Phone: ~ . ~_~ ~ ~ ~ DeepTrench D Shallow Trench O Bed D Mound D Other Total Depth from original grade: LEGAL DESCRIPTION SoilRating: ~,~- GPD/Sq. Ft. J~* It D:~c'~: Subdiv~ion: Depth to pipe bo~om from original grade: Gravel depth beneath pipe Lot: 7 ~ ~oz¢~ 8, IIz E. ~ ' Ft. ~. Z Ft. Township: ~ Range: ~ Section: Fill added above original grade: Gravel length: 1,~ Ft. ~ ~ ~ ~ I0 ~ Ft. I I WELL: Nob D New ~ Upgrade Gravelwidth: Number of lines: Distance be~een lines: ~ ~'~' Ft. ~ ~ O Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption ares: Pipe material: ~-~/O Ft. Ft. t ~ ~ SQ. Ft. 0-30 ~ Non . Driller: Date Drilled: Static Water Level: Installer; Date installed: Yield: GPM IPump set at: Ft. ICasing Height Ab°ye Gr°und:Ft. TANK SEPARATION DISTANCES ~Septic ~ Holding D S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capscity in gallons: From Tank Field Station Tank Sewer Lines ~ ~ ~ ~ { Material: Number of Compa~ments: Welk ~e e / w~t~ ~to~' >too ~ - - MFT ~T~TIO~ Line Lot ~0' ~ ~' ~ . Size in gallons:,I Manufacturer: Foundation ~ q ~ ~ ~ -- .- - "Pump on" level at: "Pump off" level at: High water alarm at: Cu~ain Pump Make & Model I Electrical Inspections pedormed by: Drain .... -- I Remarks: ~ys~e~ i~//~ ~ ~~ BENCH MARK Location and Description: Assumed Elevation: ENGINEER'S SEAL Inspectionspedormed by: ~' ~ ~ Dates: 1st "/7/97~~~e~ 2nd ~/7 197 ~ ,~-~o~o,':: ~, ~ .~,~, ~:' Department of Heal.and ~u~an~Se~ices approval ~2~:% c~. sz~,, ~,. Reviewed and approved by: _ Date: ~- 2~-G~ ~-t~z:b$:c,~?t;,,~ 72-913 (Rev. 9/91) MOA 25 I PAGE 2 OF 3 PERMIT NO: SW970025 PID NO: 01738134 TBM ,,,% 1000 GALLON SEPTIC TANK DOUBLE C.O. ~ 'H' .D. - E- 52' LONG 77. H. SOIL ABS. M.T. TRENCH 'T' ~ 'F" M.T. rep I,ac em e,~ P.. '"G" NOTE: THIS IS NOT A SURVEYED P~T. LOCATIONS OF FEATURES WITH RESPECT TO PROPERTY LINES ARE APPROXIMATE RIDGEVIEW DRIVE NOTE: PER CONVERSATION WITH KEN DUFUS ON 8/13/97 THE RESERVE AREA FOR THE LOT 8 SEPTIC SYSTEM IS LOCATED EAST OF THE PRESENT SYSTEM ON LOT 8 APPROX. SITE FOR PROPOSED WELL SWING TIES: FROM: COR. "A" COR. "B" TO: S.T.C.O. "C" 56' 48' S.T.C.O. "D" 57.5' 53.5' DBL. C.O. 'E' 59' 57' TR. M.T. "F" 71' 83.5' TR. C.O. "G" 92' 107' TR. C.O. "H" 73.5' 58.5' TR. M.T. '1" 84.5' 84' TR. C.O. "J' 95' 101' 50' LONG SOIL ABS. TRENCH LOT 8 LOT 7 ROSEBUD HILLS SEPTIC SYSTEM INST. AS-BUILT INSP. REPORT FLATTOP TECHNICAL SERVICES SCALE: 1" = 30' 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 AUGUST, 1997 'PERMIT NO: SW970025 PAGE 3 OF 3 PID NO: 01738134 INV. 88.3 1000 GALLON SEPTIC TANK INV. 88.0 1.5' FILL "~ ORIGINAL '' GROUND i', ELEV. 93.4' INV. 87.5' BOTH ENDS OF BOTH TRENCHES SEWER GRAVEL BOTTOM TRENCH ELEV. 78.3 T.H. #1 M.T. DRY ~.,,~.,~'~_'~_~,~,~,. ~'~ 8/7/97 ELEV. 69.4' ~..' ~.~ ~..?~..~ .... ~.~ LOT 7 ROSEBUD HILLS SEPTIC SYSTEM INST. AS-BUILT CROSS-SECTION FI~TTOP TECHNICA~ SERVICES NOT TO SCALE 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 AUGUST, 1997 WATER WELl. RECORO WELL DEPTH' , / ~.. DATE OF COMPL~ r ' : DEPTH,TO STATIC WATER L~ELt ' .:: GRAVEL PACK TYPE: ~:.,/~,,,:~.,. . .... '. NOV 4 1998 D~ELOPMENT M~IHOD~ PUMP INTAKE DEPTHt , ft Horsepowert {MATION; REMARKS; ": ~' · ' / , Z? ", ' ,' ".~;'~- ...: .' ','.; .... .. . ..... · ~ ...... ~",~= ',~- ~ ,',~ ~ .... ' · :, ............... · . .. .... ..n. ,~. ~; .... · Ted NU ~E:G8 866~'0E'~°0 ESSO S~ L06 qqI~ ~NISqU : PAGE 1 OF 1 MUNICIPALITY OF A/NCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970025 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:HANSEN ALLAN B & HENRIETTA OWNER ADDRESS:5701 RIDGEVIEW DR ANCHORAGE, ALASKA 99515 PARCEL ID:01738134 '~ ~ "' ' ~'~ DATE ISSUED: 2/21/97 EXPIRATION DATE: 2/21/98 LEGAL DESCRIPTION: ROSEBUD HILLS BLK 1 LT 7 LOT SIZE: 56333 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED lIND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVEDBY: DATE: ~//7 / g7 DATE: ?-- 2 ! -- CWIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 February 10, 1997 ANCHORAGE, ALASKA 99516 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dem' Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a permit to construct wastewater disposal facilities on Lot 7, Block 1, Rosebud Hills, located at 5701 Ridgeview Drive. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the soil log, the native material between 11 feet and 24 feet is a silty fine sand with a measured perc rate of 60 minutes per inch. Using the soil application rate of 0.45 gpd/sq, ft. specified in the wastewater ordinance, this 3 bedroom residence requires a total absorption area of (3 x 150)/0.45 = 1000 square feet. The proposed 2 parallel 50 foot long trenches with 10.5 feet of sewer gravel between 5.5' and 16' below ground level has 1000 square feet of effective absorption area in the designated absorption stratum. The additional sewer gravel in the trench above 11 feet will protect the installers from the danger of sidewall collapse and will provide an unquantifiable amount of supplementary absorption area. The topography of the lot slopes in the vicinity of the proposed construction slopes down towards the west at approximately 5%. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space- surface and subsurface, or on drainage. ~, Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. MUNiCiPALITY OF ANCHORAGE ENVIRONMENTAL SERVICES DIVISION FEB ! 0 1997 RECEIVED LOT 2, CbNTbUR o SEPTIC LOT 1, CONTOUR ACRES, ADDN. #2 ACRES, ADDN. #2 SYSTEM O LOT 6 (VACANT) CONSTRUCT 2 PARALLEL 50' LONG SOIL ABS. TRENCHES WITH 10' SEWER GVL. BELOW PIPE SITE FOR SIMILAR REPLACEMENT TRENCHES LOT 4 BLK. 2 FDN. ', C.O. 5% ,, T.H. ,' #2 ,' INSTALL 1000 GALLON SEPTIC TANK RIDGEVIEW DRIVE SEPTIC "- SYSTEM ' TRACT A, BLOCK 2 ROSEBUD HILLS LOT 8 , (VACANT) FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, ALASKA 99516 -- --FEET~ -- HOUSE LOT 7, BLK. 1, ROSEBUD HILLS PROP. WELL AND SEPTIC SYSTEM SITE PLAN 1 INCH = 50 FEET DRAWN BY TFM FEBRUARY, 1997 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. 20 0 20 40 60 80 100 ,/ 4" DIA. D-$034 \ DBL. ~ M.T.~ ~ J CONSTRUCT 2 PARALLEL ~ ~ BELOW DIST PIPE. BOTTOM OF ~4" DIA. ~ TRENCH AT 16' BELOW GROUND o.o. PLAN VIEW SCALE: 1" = 10'- 0" -- MONITOR TUBE _L 12" 3 ORIG. GND .... 6 INCH 4" DIA. D-3034 -- 1000 GALLON SEPTIC TANK FABRIC - 2 1/2" GVL. OF EXC. SECTION "A - A" SCALE: 1" = 8'- 0" LOT 7, BLK. 1, ROSEBUD HILLS SEPTIC SYSTEM INSTALLATION PLAN AND CROSS-SECTION FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, AK, 99516 SCALE: AS SHOWN DRAWN BY: TFM FEBRUARY, 1997 Flattop Technical Services 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 7, Block 1, Rosebud Hills S/D 5701 Ridgeview Drive Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of installation of a I000 gallon septic tank and construction of two parallel 50 foot long soil absorption trenches containing a total of 10.5 feet of sewer gravel. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All constmction procedures and material specifications shall conform with Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 Septic Tank: 2.1 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downstream of the septic tank. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating two parallel 50 foot long soil absorption trenches to a total depth of 16 feet below original ground level. 3.2 The bottom of the trenches shall be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. Sand for leveling or serving as filter material shall comply with Municipal specifications. 3.3 A total of 10.5 feet of approved sewer gravel shall be placed in the bottom of the trenches with the perforated distribution pipes laid level such that the pipe inverts are no less than 10.0 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches-of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover material shall be raised a minimum of 12 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. TEST HOLE LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) 24 B.H. COMMENTS: FLA'I-rOP TECHNICAL SERVICES 14530 ECHO ST, ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 7, Block 1, Rosebud Hills S/D September 25, 1996 Cathy Kerr Pt. SM silty loam ML Gray gravelly silt dense, damp SM Very silty fine sand Gravellier between 11' and 12' Siltier near bottom SLOPE ) 55 Ii '~ ~ T.H. #1 T.H. #2 RIDGEVIEW DRIVE [~- Depth to Groundwater Date No Groundwater 9/25/96 Monitor tube dry 9/26~6 Monitor tube dry 10/3/96 Clock Net Time Percometer Not Drop Date Reading Time (minutes) Reading (inches) 9~25 12" Presoak 9~26 Resoak Start 11:11 7 1/16 #1 11:31 20 6 11/16 3/8 Add water 11:32 7 3/8 #2 11:52 20 7 3/8 #3 12:12 20 6 5/8 3/8 PERCOLATION RATE 60 (minutes/inch) PERC HOLE DIAMETER 8" TEST RUN BETWEEN 12.5 FTAND 13 FT Test hole dug using a track mounted auger. Split spoon samples observed at 5' intervals. PERFORMED BY FLA'I-rOP TECHNICAL SERVICES. I ,'~ "~4¢,-o..,<_ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: [~/__? /~0~ TEST HOLE# 2 LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) COMMENTS: FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 7, Block 1, Rosebud Hills S]D September 25, 1996 Cathy Kerr Pt. SM silty loam ML Gray gravelly silt Softer drilling below 7' Similar to T.H. #1 SLOPE Depth to Groundwater Date No G~oundwater 9/25/96 Monitor tube dry 9/26/96 Monitor tube dry 10/3/96 SITE PLAN 55 II ~ RDGEVIEW DRIVE ~ SM Silty fine sand Similar to T.H. #1 Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) 9/25 12" Presoak 9/26 Resoak Start 11:11 6 9/16 #1 11:31 20 6 3/8 3/16 Add water 11:32 6 3/4 #2 11:52 20 6 9/16 3/16 #3 12:12 20 6 3/8 3/16 PERCOLATION RATE >60 (minutes/inch) PERC HOLE DIAMETER 8" TEST RUN BETWEEN 4.25 FTAND 4.75 FT The perc test data shown on this sheet applies to a separate perc test hole located 9 feet south of test hole #1. PERFORMED BY FLA'I-rOP TECHNICAL SERVICES. I ~7~J_~..~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: t ¢' [.? t/ ~ O/ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # O/'7- ~g- J~gt/ 1. GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address Lending agency Mailin. g address Agent Address uay phone Day phone e Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-O25(Rev. 1/91) Front MOA#21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verifythat based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Phone Address Engineer's signature Date DHHS SIGNATURE V Approved for *-/"//-///~E- bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 IRev. 1/91) Back MOA #21 Municipality of Anchorage '-' DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division , !','VIRONM[NTAL 5[:RVICES 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Legal Description: Health Authority Approval Checklist A. WELL DATA Well type 1~_ Log present (Y/N) y Total depth t t./~'~ Sanitary seal (Y/N) ~// If A, B, or C, attach ADEC letter. ADEC water system number Date completed Cased to FROM WELL LOG Date of test Static water level Well production Casing height (above ground) ~-- 7 Wires properly protected (Y/N) 5/ AT INSPECTION g.p.m. WATER SAMPLE RESULTS: Date of sample: ~ B. SEPTIC/HOLDING TANK DATA Date installed '~/'7 / ~7 Tank size Foundation cleanout (Y/N) Date of Pumping Nitrate ~,/e( ~/L~. Other bacteria Collected by: Number of Compartments Z- Cleanouts (Y/N)_TZ~.~ High water alarm (Y/N) 1,~1 ~:). q~"- System type / ~ ~ ?. ,~- Total depth /~', / · Depression over field (y/N) 1'"~ bedrooms C. ABSORPTION FIELD DATA Date installed ~ [~ I~ '] ! Length ~ ~-~!~. Width Depression (y/N) Pumper Soil rating (g.p.d./ft~ or fF/bdrm) Gravel thickness below pipe Effective absorption area ! g' ~2~ Monitoring Tube present (Y/N) '"/ Date of adequacy test J~ ~ ,L ~ ~ ~ Results (Pass/Fail) / For ~ Fluid depth in absorption field before test (in.); ' ~ Immediately after ~gal. water added (in.): Fluid depth ~'/ (ins) Minutes ater: ~ Absorption rate = ~'/ g.p.d. Peroxide treatment (past 12 months) (Y/N) ~ If yes, give date ~ 72-026 (Rev. 3/96)* D. LIFT STATION ~- V/-.~- Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested ~ E, SEPARATION DISTANCES Size in gallons "Pump on" level at* *Datum "Pump off" level at* SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot ! O 1~ Absorption field on lot i 1 ~' On adjacent lots On adjacent lots Public sewer main ~"~///~ Sewer/septic service line "Z ~ O Public sewer manhole/cleanout ~"~/~'~' Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation ,~ ? Property line 50 t ~ Absorption field Water main/service line ? J~ c~ Surface water/drainage. ~'''J /o Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Surface water Curtain drain Building foundation /-/r 7 Water main/service line /% S~,~ Driveway, parking/vehicle storage area ~ ,2. ~'-' Wells on adjacent lots ,~ / ~ ENGINEER'S CERTIFICATION · . , I certify that I have determined thru field inspections andhire;;etw of Municipal records that the above syster~¢ a e in conforrnance with MOA HAA guidelines in effect on this d, te. Signature ~ - Engineer's Name t ~ ~---~ HAA Fee $ ~'~ Date of Payment 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number CT&E Ref.# Client Name Project Name/# Client Sample ID Matrix Ordered By PWSID 986058006 Tobben Spurkland P.E. r }.1... r Lt 7 Rosecloud Hills Drinking Water 0 Sample Remarks: Client PO# Printed Date/Time 11/04/98 11:04 Collected Date/Time 11/01/98 12:10 Received Date/Time 11/02/98 08:00 Technical Director: Stephen C. Ede Parameter Results PQL Units Nethod AlLowable Prep Analysis Limits Date Date Init Total Coliform Nitrate-N o 3.19 cot/lOOmL SH18 9222B 0.100 mg/L EPA 300.0 lO max 11/02/98 KAP 11/02/98 11/02/98 GCP