Loading...
HomeMy WebLinkAboutROSEWOOD PARK ESTATES BLK 1 LT 6Olq i3q 07 GRE' TER ANCHORAGE AREA BOrP- UGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME 'D~V~ C-f'L;~q~_ MAILING ADDRESS '~l~/ J~.~Ci''t~P' C'-f', PHONE ~?~"] ~c~(jpl~ TANK: DISTANCE FROM WELL NUMBER OF MATERIAL ") -(? ~-'{5' 1 COMPARTMENTS INSIDE LENGTH ~ INSIDE WIDTH ~ LIQUID DEPTH ~ LIQUID CAPACITY ~.OO"'C3 GALLONS. S E E PA-G E~P1 T~' ....... E~ NUMBER OF PITS __ DIAM~¢ER~-~--~ OR WIDTH__ L LINING MATERIAL CRIB SIZE: DI~-~T_~~. DEPTH DISTANCE FROM: WELL / EEFECT,VE BUILDING FOUNDATION ~LINE . ABSORP'~TI~A (WALL AREA)_ ADDITIONAL ~~ ~'"~-~ % SQ. FT. WELL: TYPE .7 ~ BUILDING FOUNDATION __ CESSPOOL APPROVED CONSTRUCTION .~BPTq:~~ DISTANCE FROM: N EA ~-~.~ NEARES~ SEPTIC .SEEPAGE LOT LINE ~ , TANK SYSTEM OTHER SO U~k~S DfS~PROVED REMARKS DISTANCES: INSTALLED BY: ~ PIPE MATERIAL: LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM '30% DATE GREATER ANCHORAGE ArEA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 PERMIT NO. TELEPHONE 274-4561 --. . ~ . ,-. SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT ~ ~/ iNSTALLATION OF: ,' SEEPAGE PIT ~ , DRAIN FIELD ; ' ' , OTHER . TYPE AND SIZE O~ FACILITY TO BE SERVED ' SOIL TEST RESULTS ~2~ ~ '~/. ~ ~ NOTE: THIS PERMIT iS NOT VALID WITHOUT SOIL COMPLETION DATE ANTICIPATED FINAL INSPECTION: 2/~ HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK '~ SEPTIC TANK ., SEEPAGE PiT TO NEAREST LOT LINE WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC/TANK DRAIN FIELD / SEPTIC TANK, /~ ~ , SEEPAG~"PT~ TO RIVER, LAKE, STREAM. SEEPAGE PIT ALSO CONSIDER ARea WELLS. ., DRAIN FIELD ~ . CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSS~NG GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT PITTED WITH AIRTIGHT REMOVABLe CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGi~JLATIONS REGARDING INSTALLATION. LICENSED DESIGNER TYPE DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH OBDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE, /~) (/~* ~ (/~//~ SEWAGE DISPOSAL SYSTEM -- APPLICATION AND , DEPARTMEnt OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA g9503 TELEPHONE 274-~561 ]NSTALLAT]ON LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE serVED FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATED SEEPAGE PIT ILING ADDRESS FINAL INSPECTION: 24 Hour NOTICE REQUIRED. BACKFILII DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL ~ SEPTIC TANK SIZE TYPE , SEEPAGE AREA SIZE MINIMUM DISTANCES. R EC~UIRERIENTS "~ ~ fOUNDATION TO ~PIT -- ~ ~ ~ ' ~ ~ ' E L D ' -- / { WELLTO SEPTIC TAN" ~, SEEP)~E PIT ,/ ~AIN FIELD ~ A~6¢ONSlDE~ AR~A WELLS. EXCAVATION ~ FEET I~U~BED ~OIL, IER RMIT IS NOT VALID SOIL TEST TYPE DIAGRAM OF SYSTEM GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. I CERTIFY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCH POR~ NO, AND THAT THE ABOVE '-~ $ ~9o59'20"~- 50.0' 0 0 ~~ ~.l. JIT~'' A · AN,~HORAGIg, A~AS~.A 9950~, · Z77.02~,1 July 31, 1975 Rolf Stickland Greater Anchorage Area Borough Department of Environmental Quality 3330 "C" Street Anchorage, Alaska 99503 Dear Mr. Strickland: Enclosed are copies of the test log of Lot 6, Block 1, Rosewood Park Estates and mechanical analyses for 2 samples taken from this test pit. Surface water was apparent around the test pit location and prevented making an actual perco- lation test due to the surface water running into the test hole. The actual test pit did not contain ground water at the time of the test?nd moistures of two samples were taken to demonstrate this. A soils log of the adjacent lot is enclosed for your in- formation. Mr. Dick Schopf of Aerobic Sewage Purification, Inc. will be getting in touch with you to discuss placing a Multi- Flo unit on this lot. If you have any qUestions, please call. Yours very truly, CONSTRUCTION TEST LAB Hausam~ P.E., L.S. NAH/d~ Performed for Legal Description: GREATER ANCtIORAGE AREA Department of Environmental Quali 3330 "CI' Street Anchorage, A1 aska 99503 SOILS I,O(; - PEROI,ATION TEST Bill Kelly Lot 6, Block 1, Rosewood Park Estates Date Performed ..... 7_~_ _2,_4./_2_~ This form reports: Soils log Yes Percolation test Dep th Feet &" Black Peat & 0r~an~c.$ . /~,t Damp Grey Silt lenses Damp Grey Sandy Silt with Gravel & Sand Lenses 300 S.F./B.R. sa. 1-1 Damp Grey Silty Sandy Gravel -wiF~oDo ]l - occasional boulders & sand lenses 12 - 250 S.F./B.R. 13 - sa. 1-2 14 - BQ~om of test hole /~as ground water encountered?· No Water at surface sample Reading If yes, at what depth? __ Date Gross Time · I Depth to Water Net Time Net Drop Pe'r~o-6T~-i 6 n Fai6- ..... minute. -Proposed installa~q-~n-.'- Seepage Pit Yes Drain Field __ . ....... Depth to bottom of pit or trench 15' Depth of Inlet .................. · ~- COMMENTS: ...... m.~ ~q~gB~~_~_~_¢~r~:~t o r *O: - ~~ ~/ SOl LS L~,.. ~o. PROJECT -'~ ~/'- / SIEVE : ' ' ?2 ': ANALYSI S SPECIFICATION ~ REMARKS SIEVE WEIGHT RETAINED PERCENT EETAINED % PASSING LIMITS SIZE ~US ~ MINUS ~4 SIEVE CUMULATIVE ~ :7 1112 1,,? :~/: - ' 140 MATERIAL' FINER THAN NO. ~00 SIEVE ""~ JL31_ ~.o~ .',, 200 '~ ' -'~-- P ~ N % I' SOILS ~.As..o. SIEVE WEIGHT RETAINED PERCENT RETAINED % PASSING SPECIFJCATI~ REMARKS SIZE ~US =4 MINUS =4 SIEVE CUMULATIVE LIMITS PAN "ONE TEST IS WORTH A THOUSAND OPiNiONS" 3919 SPENARD ROAD, SUITE A · ANCHORAGE, ALASKA 99503 · 277-O231 July 31, 1975 Rolf Stickland Greater Anchorage Area Borough Department of Environmental Quality 3330 "C" Street Anchorage, Alaska 99503 Dear Mr. Strickland: e test log of~ mechanical analyses for 2 samples ~is t~s~--~'. Surface water was apparent around the test pit location and prevented making an actual perco- lation test due to the surface water running into the test hole. The actual test pit did not contain ground water at the time of the test and moistures of two samples were taken to demonstrate this. A soils log of the adjacent lot is enclosed for your in- formation. Mr. Dick Schopf of Aerobic Sewage Purification, Inc. will be getting in touch with you to discuss placing a Multi- Flo unit on this lot. If you have any questions, please call. Yours very truly, CONSTRUCTION TEST LAB ~Neal A. Hausam, P.E., L.S. NAH/dt MUNICIPALITY OF ANCHORAG~-~-~ OF HEALTH AND ENVIRONMEN] Street, Anchorage, Alaska 279-2511, ext. 224 or 225 Date Received: #2: Time Date ~ PROTECTION -99501 Insp April 13, 1977 #3: Time Date Insp ~SO ~ ~ m_uq ~;s~, ~/~ REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES Lending Institution Request: National Bank of Alaska % Ruth ~3o~ u Mailing Address: Post Office Box 3-3859 99509 Phone: 279-2506__ 2. Property Owner: William F. Kelly Phone: 344-8473 Mailing Address: 2110 East 72nd Avenue ~£/%/_ ~_~. 3. Legal Description: Lot 6 Rosewood Park Estates Subdivision 4: Single Family Residence: ~ Multiple Family Residence: Number of Bedrooms: Number of Bedrooms: Well System: Permit # Construction Public/Community System: ~) Individual Well: Depth of Well Well Log on File ( Bacterial Analysis 6e Sewage Disposal System: Permit # Septic Tank Size Absorption Area On-site System (~ Public Utility ( ) Installed Installer Manufacturer Soils Rate Material 7. Distances: Well to Septic Tank to Absorption Area to Sewer Line Nearest Lot line Absorption Area to Nearest Lot Line Page ~wG ~ Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 6 Rosewood Park Estates Subdivision Affadavit Attached: ~ (') Letter Attached Approved ~----~-~-~2 ~? D~O: ~.2~,~ ..... D±$approved: Da'~-e: De'p~rtment Worksheet: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L Street-, Anchorage, Alaska 99501 279-2511, ext. 224, 225 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES ~UNICIPALfl-'¢ OF ANCHORAGr. DEPT. OF HEALTH & ENVIRONMENTAL PROTECI'ION APR I 1977 RECEIVED 1. Type of Inspection: 2. Property Owner: Mailing Address:__ 3. Name of Buyer: Mailing Address: __ Name of Lending Institution: VA__ __ FHA __ ? ~- ,~ Day ~hone: CONV Mailing Address: 5. Name of Realtor or Agent: Mailing Address: 6. Legal Description: Location: Day Phone: Type of Facility to be Inspected:/?~~ Water Supply Type of Supply: Public Utility. ~ If Individual, number of dwellings presently served No. Bdrms. ¢ Individual If Individual, depth of well 9. Sewage Disposal System Type of System: Public Utility Individual (on-site) If Individual, date of installation 72-003(3/76} Tt~,iI..EF{. CC4~F~V 7io0 [ E. 72 ~-UE. ~ .I K. 73 AVE .............. IPI ,, ~[ ................... ~r I I ll~I ........ ~ t .................. J .......... 72i~. 72/7 7Z2~ 7227 72 ~& 72 37 /'~l& 732& E. -[6 ~VE. AVE. 7q~7 ~' 7507 7520 117 127 ~<~ 129 137 Abbott Loop Area Reference Map-Pll