On-Site Water & Wastewater Section Fax: 907-343-7997
Pump Installation Log
Well Drilling Permit Number: _______________ Date of Issue: ____-____-____
Parcel Identification Number: ____-____-____
Legal Description Block Lot Property Owner Name & Address:
Pump Installation Date: _____-_____-_____
Pump Intake Depth Below Top of Well Casing: __________ feet
Pump Manufacturer’s Name: ___________________________ Pump
Model: _____________________________________
Pump Size: ____________hp
Pitless Adapter Burial Depth: _________ feet
Pitless Adapter Manufacturer’s Name: _________________________
Pitless Adapter Installer: ____________________________
Well Disinfected Upon Completion? XX Yes No
Method of Disinfection: _____________________________
Comments:
Pump Installer Name: __________________________________
Company: ___________________________________________
Mailing Address: ______________________________________
City: ___________________ State: __________Zip: _________
Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation.
Municipality of Anchorage
On-Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211284 PID Number: 012-153-47
Dwelling: W Single Family (SF) F-1 with ADU [I Duplex (D) El Two Single Family Project: n New W Upgrade
Name
WOODS FAMILY 2001 TRUST
ABSORPTION FIELD
F-1 Deep Trench F-1 Wide Trench n B�ed;Zou n d
Site Address
3550 WEST 75TH AVENUE -ANCHORAGE, AK
El Other
Phone
Number of Bedrooms
Soil Rating
Total depth original grade
907-227-5203
15
GPD/SF ;
>1�4 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grad
:��Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
ROVEL; LOT 1
Fill added above original gr a
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
TO!
Septic
Absorption
I
Lift Station
Holding
Sewer
Total rption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
Well
*55'+
TANK X Septic [3 S.T.E.P. El Holding 0 Other
Manufacturer
GREER TANK
Capacity
1500 Gal,
Surface Water
100'+
Material
Number of compartments
Lot Line
5'4
NA
HDPE
2
Foundation
10'+
LIFT STATION
,
Manufacturer
Capacity
Remarks OLD TANK DECOMMISSIONED PER UPC
Gal.
PER CONTRACTOR *WR#OSV211045
Alarm location
Electrical installed by
PIPE MATERIAL House totank EXISTING/ Tank to EXISTING/
Installer
A+ HOME SERVICES
D3034 drainfield D034
Drainfield EXISTING CO/MT D3034
Inspector GEG AND MOA
BENCH MARK (Assumed elevation) 99.37 ft
Inspectes:tion 15t 9/30/2021
Location and description
da2'
TOP OF MH
3rd - 4th
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineers Stamp
Conditional Approval: Date
C/)
T
... ..........
f A. Go 7 ness.,
Septic System
Approved DateQuo
Note: this approval does not include well permit requirements.
0 f S S
#AECC884 DOpO
krxt�v Uoluzi !0)
PERMIT NUMBER:
OSP211284
I A I B I
DBLI 27.4 29.4
DBI -2
28.3
30.1
MH
29.8
31.2
ST1
33.7
34.5
DBI -3
35.3
34.9
DBI -4
35.9
34.4
RECORD DRAWING PARCEL ID NUMBER:
012-153-47
ISERVED BY PUBLIC WATER AND SEWER I
WEST 75TH AVENUE - - - - - -
-EL'
RAV DRIVEWAY
4-4 A 01UTP9 W
tffARNESS ENGINEERING GR Ltd
ENGINEERING SALES, CONSULTING . ....... ..
3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507' PHONE (907)337-6179- FAX (907)338-3246 - WEBSITE: —.g--g—.-g.cam
PREPARED FOR: HONE NUMBER: PAGE NUMBER:
WOODS FAMILY TRUST 2021 --7907-227-5203 20F3
LEGAL DESCRIPTION: DRAWN BY:
ROVEL; LOT 1 D.J.G.
TYPE OF WORK: DATE:
SEPTIC TANK RECORD DRAWINGS 10/28/2021
it
O
Z
m
0-
m
0
w
w
co
0n, A.3 Hess
.
0 ................ --, .......
# �e�ey A.
�r
##
LICENSE#44
#AECC884
GARAGE
55 2�AoA5
NEW 1500 GALLON
HDPE GREER TANK ----\
I
\
/
EXISTING
w
HOUSE
2
w
DBL3&4 04
U)
B
b
APPROXIMATE LOCATION OF EXISTING
EXISTING SEEPAGE PIT PER 1975
INSPECTION REPORT; PASSED A 5
BEDROOM ADEQUACY TEST ON 6/9/2021
HANSEN SAND LAKE; LOT 16A
S
/
\
/ /
G
4-4 A 01UTP9 W
tffARNESS ENGINEERING GR Ltd
ENGINEERING SALES, CONSULTING . ....... ..
3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507' PHONE (907)337-6179- FAX (907)338-3246 - WEBSITE: —.g--g—.-g.cam
PREPARED FOR: HONE NUMBER: PAGE NUMBER:
WOODS FAMILY TRUST 2021 --7907-227-5203 20F3
LEGAL DESCRIPTION: DRAWN BY:
ROVEL; LOT 1 D.J.G.
TYPE OF WORK: DATE:
SEPTIC TANK RECORD DRAWINGS 10/28/2021
it
O
Z
m
0-
m
0
w
w
co
0n, A.3 Hess
.
0 ................ --, .......
# �e�ey A.
�r
##
LICENSE#44
#AECC884
PERMIT NUMBER: PARCEL ID NUMBER:
?SP211284 RECORD DRAWING 012-153-47
TOP OF MANHOLE = 99.37
98.8-98.9
MH1 ST1
left
TOP OF TANK AT INTLET = 94.42 f TOP OF TANK AT OUTLET = 94.41
J
INVERT OF BUNG AT INLET = 93.77 INVERT OF BUNG AT OUTLET = 93.58
NEW 1500 GALLON
H.D.P.E. SEPTIC TANK
F 44
O'W
T; •�•
T Ltd
� �a .� ENGINEERING a. SALES -CONSULTING 91.Jx 'a.,v W �. r .......�. .......... ......
00
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 33&3246' WEBSITE: w w gamessengneenng,mm • ................ . .
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0",•, ,
s. ffrey ..i
WOODS FAMILY 2021 TRUST 907-227-5203 3 OF 3 ���'i'' _795 �! AV
AV
LEGAL DESCRIPTION: DRAWN BY: YAV
ROVEL; LOT 1 D.J.G. F.. I �.'••••'���• :.4'
E OF WORK: DATE: LICENSE'11 "'1
TYPESS` !
SEPTIC TANK PROFILE 10/27/2021 #AECC884 ��������
-------------
SHIPPING
CONTAINER
N
--------------------
WEST 75TH AVENUE ---------------------------
�n
=
GRAVEL 3 7'
DRIVEWAY
EAST 117.98'
24.2'
-----
28.0'
LU
ATTACHED
SHED z'
U.
LOT 2
GARAGE
I
0 0
I
~
IW
SHED
W
Iw
IQ
w
28.0'
Z
O
WELL
I
LL7
OI
N
CHIMNEY'"\ I o
to
co
26.
,50,
gp
'T
LOT 1I
o
15,957 sq. ft. 8.00'
I
04
cs,
8.°o,
o
01
rn
I
31.5'
2 -STORY 4.00' I
o
O
FRAME
�
HOUSE
LOT 17
SEPTIC i,',j-� ` p
0 I
O
STANDPIPES=� SEPTIC Cp
M
MANHOLE co
I
I
LOT 3
10.00,
DECK
47.5' 20.50'
CANTILEVER
I
I
I
x x x x x x
x x x x x
x
FENCE WEST 117.44'
I�
LOT 16A
i
*: 49 L
. ;
... .;
i �'• Buku S t o
0
10' 20' 1 J LS -14837 �J -
�I�4F'•.
AS -BUILT
1��8�202�.•' �,�
���t����FESSIONP 0�
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE
LOT 1, ROVEL SUBDIVISION
RECORDED SUBDIVISION PLAT (72-192) ARE NOT SHOWN HEREON.
ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT
THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEY AND
THE IMPROVEMENTS AS DEPICTED HEREON
EXIST AS
IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY
SHOWN IN RELATION TO THE PROPERTY LINES.
SURVEY MAY DISCLOSE.
DATED THIS 8th DAY OF NOVEMBER, 2021,
AT
UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE
ANCHORAGE, ALASKA.
USED FOR CONSTRUCTION
OF FENCES, IMPROVEMENTS, OR FOR
ESTABLISHING PROPERTY BOUNDARIES.
HEIGHT,
FIXED HEIGHT LLC
C.O. A. 122554
Land Surveying Services
907.290.8949
JOB # 21094B
NO CORNERS SET THIS DATE SCALE 1 "= 20'
225 W 23rd Ave., Anchorage, AK 99503 WWW. FIXEDHEIGHT COM
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
POBox 1yO6o0 ^n0Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
Permit Number: OSP211284
Work Type: SepticTank Upgrade
Tax Code Number: O1215347OOO
Site Legal Address: ROVELLf 1 G:2126
Site Mailing Address: 35G0VV75THAVE, Anchorage
Owner: WOODS FAMILY 2UO1TRUST
Effective Date
Expiration Date
7MS/2O21
7/16/2022
Lot Size in Sq Ft: 15920
Design Engineer: GARNESSENGINEERING GROUP LTD Total Bedrooms: 5
This permit iefor the construction of:
L] Disposal Field Septic Tank [] Holding Tank El Privy [] Private Well [1 Water Storage
All construction shall bainaccordance with:
1 The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (i3AAC8U)
J. The wastewater code requires inspections during the installation. The engineer shallnotifythe Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall beeither:
a Opened and Closed onthe same day, or
b. Covered, sealed, and heated to prevent freezing
Received By:
Issued By:
Municipality ®f Anchorage
ur'rt I 1 %.
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997
http://www.riiuni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV211045 COSA#: Permit#:OSP211284
PID#: 012-153-47
Legal Description: Rove[ Lt 1
Engineer: Garness Engineering Group
Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the
private well has been approved. The approved separation distance is 55.0 feet.
This waiver approval applies to the proposed septic tank only. Any fixture upgrade to the on-site
wastewater disposal system will require all separation distances be met or another approval from
this department.
............................................... ■ ............................. ■ 1
Waiver is Granted: X
Waiver is not Granted:
Date: /� Z I Approved by:
Name of Review
**** VARIAN C E/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Development Services Department K„ Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 012-153-47
Property owner(s) WOODS FAMILY 2001 TRUST (Catherine) Day phone 907-227-5203
Mailing address
Site address 3550 WEST 75TH AVE *ANCHORAGE, AK
Legal description (Sub'd., Block & Lot) ROVEL; LOT 1
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field ❑
Initial ❑
Single Family (SF) 0
(w/wo ADU)
Septic Tank E
Upgrade M
(D) El
Holding Tank ❑
Renewal F-1Duplex
Multiple Dwellings ❑
Privy ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES
A WAIVER REQUEST FOR:
WELL TO SEPTIC TANK
Distance: 55 FEET
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees 22 Waiver Fees: - 18 U
Date of Payment: `� r)_0 �L Date of Payment:
Receipt Number: 09115 co Receipt Number:
Permit No. 0,f) P Z 1128c -j Waiver No. _ 0.5U Z I I ouf .S
G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211284, Deb Wockenfuss, 07/16/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211284, Deb Wockenfuss, 07/16/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211284, Deb Wockenfuss, 07/16/21
.9Z N
N _ < LLi,99'9C AA ,OOZOoOO S ] I
r
C) -. 6Co LIJ
W �0 cv
!-- W r.: w
x Q n cs u_
1N3 3 V3 .kinun m
t3 p a.
" U?L ui
>UJ
a- ujLO
w -ru� o
< 00- O H
U)
• .'. o U-
�""i "'*w i 0 (} iV
LIJ IM 0 — 0 (L) 0
a £L D W W 0)
W c
ui 0w_ Di
Z—) :E w m0 0 ZZZ e � ��
tD 16.5 _ — U- -j < U) D < L J C,4
,,•
CN
l
-e111 Q LLuiW
CV 0
,.'313UON '00>,00
ui
CO UJ UJ UJ U—
cei
1
46.{x' W- • '.-'UJ .
19Z N
< :4 0 -r t ---i %.0'
#00 p 444
>LQ 3: LU
W c6 o6 x �� ��. .► (1) F- D t
t > c`+1 CC ,r ,-� to i F- > uj
LL' t � • Qty .: L1J 0 0U- 0 F-
0 t �- - . . • a -= 0 W < < CL
n
> U)
UJ
W wz w00 W
u N U � U) civ CL 00
0t� n CL 00 0
a. z Q ct3 x 0{ W Z W F- U W
wa z 0
0
W 0 F- QW
0D W0� w
© n
N 99 199 W 135.56,
a W0 co n> w®co
w _n z U) 0
W t F- U) U) D W
GREAT ANCHORAGE AREA BOROI' H
Department3330°f EnvironmentaIc Street Quality
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
PHONE
LOCATION
LEGAL DESCRIPTION
SEPTIC TANK:
DISTANCE
FROM WELL ~)~ ~ ~ NUMBER OF
MANUFACTURER ~ V'~'~K' MATERIAL ~ '~(C E~ / COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY /~'O ~ GALLONS.
SEEPAGE PIT:
NUMBER OF PITS J DIAMETER __
LIN,NG MATERIAL c~'/~t3~ I
BUILDING FOUNDATION ~t~~,
ADDITIONAL ABSORPTION
.OR WIDTH ~'0~. LENGTH'~'0~', DEPTH IN'
CRIB SIZE: DIAMETER (0 DEPTH ~ DISTANCE FROM: WELL ~ ~
~ TOTAL EFFECTIVE
NEAREST LOT LINE ~ ABSORPTION AREA (WALL AREA) ~7 ~/. C) SQ. FT.
WELL:
TYPE AY" )1 e<:~ CONSTRUCTION
BUILDING NEAREST
FOUNDATION LOT LINE
CESSPOOL OTHER SOURCES
APPROVED DISAPPROVED
~k/)/')~'~) ~2 ~C~ DEPTH DISTANCE FROM:
NEAREST SEPTIC ~ SEEPAGE
SEWER LINE TANK ~'¢ SYSTEM q0'
REMARKS
DISTANCES: ~ 0/'/"'
HNST~LLED BY:
PIPE MATERIAL:
LOT SLOPE:
REMARKS:
Form No. ED-031
DIAGRAM Of SYSTEM
I~,
DATE
GREATer ANCHOrAGe AREA Borough
DEPARTMENT OF ENVIRONMENTAL QUALITY
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
NAME OF APPLICANT
iNSTALLATION LOCATION
INSTALLATION OF: SEPTIC TANK SEEPAGE PIT , DRAIN FIELD OTHER
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTIDE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SiZE ,//' ~'~ r ' ·' . ' SEEPAGE AREA SIZE TYPE /"'~ ...... --
DIAGRAM OF SYSTEM
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT ~0
SEPTIC TANK TO SE AGE PIT WALL
J , SEEPAGE PIT
TO NEAREST LOT LINE·
DRAIN ~IELD
DRAIN FIELD
., DRAIN F~ELD
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
SEPTIC TANK, /~ ~ , SEEPAGE PIT
TO RIVER, LAKE. STREAM~
SEEPAGE PIT
J~)~ , DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND into CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 inCH DIAMETER CAST irON SIPHON PIPES ON EPTIC TANK AND SEEPAGEt/PIT
I CERTIFY THAt,Am FAMILIAR WITH THE REQUIREMENTS Of GREATER AN~ORAGE Al OROUGH~O~A(~DD~NZNN~NO~/~'~//8/~ AND~HA~/T T2 T~T~HIg ABOVE
Performed For
Leaal Descrintion: LotJ3.__Block
This form Re~orts Soils LoQ ¥E$
"On~ te~ is worth a th~sand o~Jn'ons '
Mr. Roger Woods Date Performed 3/3/75
Subdivision Rovel Subdivision
Percolation Test
oe~th
Feet Soil Characteristics
5--
7 .
8
9--
lO--
Foundation Grade
Sand, well graded
Clean Moist
SW - 125
(Sand continuous through out
depth'of test hole)
/~;~i;.Bottom of test hole
If Yes, At what De~th?
Reading Date Gross Time Net Time Depth to H20 Net Drop
Percolation Rate t~inute
Pronosed Installation: Seepage Pit YES Drain Field
Deoth of Inlet Depth To Bottom Of Pit Or
CNMgENTS: 125 square feet drainaqe area required per bedroom -
No bedrock or water table encountered.
Trench
Sest Performed B¥CONSTRUCTTON TES~ T,nn Data Certified By:CONSTRUCTION ~T LAB
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURCES
DIVISION OF MINING, LAND & WATER
Alaska Hydrologic Survey
WATER WELL LOG Revised 08/18/2016
Drilling Started: ____/____/______ Completed: ____/____/_______ Pump Install: ____/____/_______
City/Borough Subdivision Block Lot Property Owner Name & Address
Well location: Latitude Longitude
Meridian ____________ Township ______ Range _______ Section _______ , _____ 1/4 of _____ 1/4 of _____ 1/4 of _____ 1/4
BOREHOLE DATA: (from ground surface)
Suggest T.M. Hanna’s hydrogeologic classification system*
https://my.ngwa.org/NC__Product?id=a185000000BYub3AAD
Depth
From To
Drilling method: Air rotary, Cable tool, Other
Well use: Public supply, Domestic, Reinjection, Hydrofracking
Commercial, Observation/Monitoring, Test/Exploratory, Cooling,
Irrigation/Agriculture, Grounding, Recharge/Aquifer Storage,
Heating, Geothermal Exploration, Other
Fluids used:
Depth of hole: __________ ft Casing stickup: ___________ft
Casing type: __________ Casing thickness: _________ inches
Casing diameter: _________ inches Casing depth: __________ ft
Liner type: _________ Depth: _____ ft Diameter: _____inches
Note:
Well intake opening type: Open end, Open hole, Other
Screen type: _________, Screen mesh size: ____________
Screen start: ________ ft, Screen stop:________ ft, Perforated Yes No
Perforation description: Perf from: ________ ft, Perf
to: _______ft, Perf from: ________ ft, Perf to: ________ ft
Gravel packed Yes No Gravel start: ______ ft , Gravel stop:______ ft
Note:
Static water (from top of casing): _______ ft on____/____/_____ Artesian well
Pumping level & yield: ______ feet after _____ hours at _____ gpm
Method of testing:__________________________________________
Development method:______________ Duration: ____________
Recovery rate: _________ gpm
Grout type: _________________ Volume __________________
Depth: From ___________________ft, To ___________________ft
Final pump intake depth: __________ ft Model: _______________
Pump size: _____________ hp Brand name: __________________
Include description or sketch of well location (include road names,
buildings, etc.):
Was well disinfected upon completion? Yes No
Method of disinfection:
Was water quality tested? Yes No
Water quality parameters tested:
Well driller name: ..................................................................................
Company name: ...................................................................................
Mailing address: ....................................................................................
City: __________________________ State: AK Zip: ___________
Phone number: (________) ________- ______
Driller’s signature:
Date: ______/______/_________
Anchorage Municipal Code 15.55.060(I) and North Pole Ordinance 13.32.030(D) require
that a copy of this well log be submitted to the Development Services Department/City
within 30 days of well completion.
City Permit Number: _____________________________
Date of Issue: _____/____/_________
Parcel Identification Number: ______-_______-________
*Guide for Using the Hydrogeologic Classification System for Logging
Water Well Boreholes by Thomas M. Hanna NGWA Press
AS 41.08.020(b)(4) and AAC 11 AAC 93.140(a) require that a
copy of the well log be submitted to the Department of Natural
Resources within 45 days of well completion. Well logs may
be submitted using the online well log reporting system
available at:
https://dnr.alaska.gov/welts/
OR email electronic well logs to
dnr.water.reports@alaska.gov
North
012N
0 74
sand and clay - no water
ROVEL
238
23380
S 02
n
-149.945521
233
SE
77
intermittent layers of sand, clay, and clay and gravel
61.15273000000002
1965
SWSE
233
233
CASED TO 233 FT. OPEN END, HOLE DEPTH 258 FT
SW
COTTEN DRILLING
18443
74
n
7
n
n
L01
8.7
250
ALLAN THOMPSON ,
fine sand
004W
n
80
clay with some sand
238
258
sand, some clay
25
gravel w/water
250
OSOgoOIlO
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Certificate of On -Site Systems Approval
OSC251026
Parcel ID 012-153-47
Legal description ROVEL LT 1
Expiration Date: 1/17/2026
Site address 7500 BLACKBERRY ST
Current property owner(s) WOODS FAMILY 2001 TRUST
X The On-site system(s) is/are approved for 5 bedrooms
By:
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
syster{(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
De`elopment Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
Conditional approval for bedrooms, with the following stipulations:
Comments or conditions:
ATTACHMENTS:
COSA Checklist
Absorption Field Advisory
Tank Age Advisory
Other
X Well Flow Advisory
Nitrate Advisory
Arsenic Advisory X
MUNICIPALITY OF ANCHORAGE
l
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section —� Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 012-153-47
Complete legal description ROVEL LOT 1
Location (site address) 7500 BLACKBERRY STREET ANCHORAGE, ALASKA 99502
Current property owner(s) WOODS FAMILY TRUST Day phone
2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS
3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass
Age 4 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ® Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee / Waiver Fee $
/
Date of Payment 2 �/ �Z 5- Date of Payment
COSA # 05 C 2_5/ 0 2.6 Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: ROVEL LOT 1 Parcel ID: 012-153-47
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 7/25/65 Total depth 258 ft
Cased to 233 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 1/23/2024
Static water level at beginning of test 75 ft.
Well production at time of test 4 gpm
Water storage tank volume NONE gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic 36.3 ug/L Arsenic less than MRL (ND)
Collected by Date 1/17/25
Comments: High arsenic levels analyzed & would recommend point of use water treatment at kitchen sink.
B. TANK DATA
Measured operating fluid level in septic tank 68”
Date of pumping 1/21/25
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 5/30/75
ALL standpipes present per record drawing
Total measured depth from existing grade 13.8 ft (max)
Measured depth to pipe invert from grade 4.8 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced 2000 gallons 1/22/25 date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 1/23/25
Results Pass
Fluid depth prior to test 30 in
Water added 750 gal
New fluid depth 46 in
Elapsed time 1440 min
Final fluid depth 29 in
Absorption rate 750 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 108 in (MOA 9’ ED)
Effective depth used 29 in (Final Fluid Depth)
Effective depth (ED) remaining 79 in
Comments/Deficiencies: Approximate total measured depths from existing grade. Pipe invert calculated using apparent
top of crib measurement.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No *55 ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
*SEPTIC TANK TO WELL, WAIVER #OSV211045.
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 1/30/2025
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
01/30/25
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT 907-343-7904
On -Site Water and Wastewater Section Fax: 343-7997
www.muni.org/onsite `-
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC251026
Subdivision: Rovel, Block: , Lot: 1
A water sample revealed an arsenic concentration of 36.3 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Information on arsenic is available from the On -Site Water and
Wastewater Program website (www.inuni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.