Loading...
HomeMy WebLinkAboutKNOLL ON THE WOLD BLK 1 LT 11 Municipality of Anchorage Page / of. 2_' DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION ' P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~'l,d~.~¢4(~9 PID Number: Name: Waslewater System: D New ~pgrade Address: ABSORPTION FIELD. -' No. of Phone: Bedrooms: ~eep Trench D Shallow Trench ~ Bed ~ Mound ~ Other ~ - LEGAL DESCRIPTION so, Rating: ~. ~ GPD/Sq. Ft. Total Depth from original grade:/~, ~ot: Block: Subdiv~ion: Depth to pipe bottom from original grsde: Gravel depth beneath pipe Township: Range: ~ Section: Fill added above original grade: Gravel length: ~ Ft, ~] Ft. WELL: U New ~1 U pg rade Gravel width: Number of lines: Distance between lines: Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: F~/~ D~te installed: Driller: Date Drilled: Static Water Level: installer: ~ Yield: I Pump Set at: C8sing Height Above Ground: TAN K GPMI Ft. Ft, SEPARATION DISTANCES ~ s.pt~o ~,¢~ ~ Ho~di,O ~ S.T.~.P. TO ~ Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ~1~~ Materiak Number of Compadments: Sudace . ~Ot 8izo in Oallons: ~ Foundation / ¢ ~ ~ / ¢ ~ ~ "Pump on" level at: "Pump off" level a~~er~ alarm at: Pump Make & Model Electrical Inspections pedormed bY: Drain BENCH MARK Remarks: Location and Description: ~, Assumed Elevation: EN61NEER'8 SEAL inspections performed by: ~.¢e myer, ~.[, ~ Dates: 1st %Jl~Jea Bepart~ent of Health3and ~um~Services approval/ ..... ~' .... :~'~ "' 72-013 (Rev. 9/91) MOA 25 Permit No. RW~0464 Page 2 of Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report KNOLL ON THE WOLD SUBDIVISION, Legal Description:BLOCK 1, LOT 11 PIDNo..04105147 CO1  EXISTING · 1000 GAL SEPTIC TANK D.E.C. WAIVER ISSUED FOR 140' SEPARATION DISTANCE BETWEEN CLASS 'C' WELL AND SEPTIC SYSTEM ON LOT 10 WOOD EXISTING lO00 SEPTIC TANK (INTEGRITY VERIFIED) DBL EXIST. ABANDONED THAT IT MAY BE USED IN THE FUTURE , FCO SCALE 1" = 40' 72-013 A (2/91) MOA 25 C02 WELL MT 88.4 A B ?CO 18.0 8.5 201 25.5 1%[ 202 30.0 22.( O,V. 55.5 27.( SO3 38.0 25.~ ~04 54.0 32.( 205 97.0 87.( M.T. 88.0 77.( TRENCH MT C05 · 82.4' NO WATER FOUND ENGINEER'S SEAL :, M.nicipaiity of Anchorage ? ~ 825 "L' Stroet, Anchoraoo, Alaska 00502-0~50 :" SOILS LOG -- PERCOLATION TEST ' ~ Township, Range, Section: ': J i.; (~} 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19- 20 WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Oeplh to Waler After Monilorino? Date: P E Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE __ (m~nutes/~nch) PERC HOLE DIAMETER TEST RUN E~ETWEEN _..~____ F~ AND _ COMMENTS ,.~ ~ ~ ,_N~INEF. RING Road No. '2.C4 ~:/ / PERFORMED BY: ~ ~~ _ CERTIFY THAT THiS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPALGUIDELIN~S~E~ONTH[SDATE. DATE: / 72-008 (Rev, 4/85) PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW930464 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:WILLIAMS LEROY C & OWNER ADDRESS:7320 MONTAGUE CR. ANCHORAGE, AK 99507 DATE ISSUED:il/03/93 EXPIRATION DATE:il/03/94 PARCEL ID:04103147 LEGAL DESCRIPTION: KNOLL ON THE WOLD BLK 11 1 LT LOT SIZE: 58535 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE~ DATE: ROBERT SHAFER, P.E. ROGER SHAFER, P.E. October 27, 1993 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECNANICAL INSPECTIONS ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN Municipafity of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street Anchorage, Alaska 99519-6650 REFERENCE: Knoll On The Wold Subdivision, Block 1, Lot 11 We request you issue a permit to upgrade the septic system serving the three bedroom house on the referenced property. An adequacy test performed on the existing system for Health Authority Approval purposes found the absorption capacity of the existing system to be inadequate. A test hole was excavated and a percolation test performed in the area of the proposed upgrade. The approximate location of the test hole is located on the attached site plan. The monitoring tube within the test hole has been checked and found to be dry. Attached it the proposed upgrade design. We do not ant/c/pate any adverse effects on neighboring properties by the installation of the proposed septic system. If you have any questions, or require additional information for your review, please contact us. Sincerely, /~ .... i~obert A. Shafec P.E. RAS/LSU/Isu 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 :~ 'Laq2$ ,0! l~Al~I(I q2AV~ID NOI,I, VONDOA 8 0 0 0 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: (ENGIREER~S SEAL) LEGAL DESCRIPTION: ~-~LL- (~/kJ Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT ~ b DEPTH? P E Depth Io Water Alter Monitoring? Date: Gross Net Depth to Net Reading Date Time Time Water Drop I0 I':1 I'>~-cc / l' 7-_-_-_-_-_-_-_-_-~d,,~ ~ ~ " -- PERCOLATION RATE ) ~ ' tmlnutes/mch) PERC HOLE DIAMETER ~ TEST RUN BETWEEN ~...~-'~AND ~'~ ~_ FT rcnrun,v,cu ....... ;~.; ,.;Va, Loop Road No 2~ ///// ACCORDANC~ ~1[~i~1~PAL GU;D~L~N[:~: ~ m~ D~E ~TE: 72-008 (Rev. 4~85} ~ ON-SITE WASTEWA TER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Knoll On The Wold Subdivision, Block 1, Lot 11 GENERAL: 1. The scope of this project includes the installation of a leachfield trench to serve the three bedroom residence located on the referenced property and excavation of the existing 1000 gal septic tank to verify its integrity. If the integrity of the existing septic tank is poor the existing septic tank is to be excavated, pumped, crushed, and abandoned in place and a new 1000 gal septic tank installed. Construction shall be in accordance with the approved site plan and design drawings; Municipal permit with any special provisions or conditions; and afl applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner responsible for final grading areas subsequently depressed settling. shall be from soft Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shaft include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Page Two Knoll On The Wold Subdivision, Block 1, Lot 11 October 27, 1993 Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final grave/layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter and installed approximately in the locations shown on the design. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six ¢6) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Knofl On The Wold Subdivision, Block 1, Lot 11 October 27, 1993 MINIMUM MA TERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The foflowing pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe_ Perforated Solid Cast Iron Yes ASTM D3034 (PVC) Yes ASTM F810 (HDPE) Yes ASTM D2662 (ABS) Yes Yes Yes No Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, it's gradation specifications must conform to current M.O.A. or D.E.C. requirements. ~ ~-~, MUNIClPALI'F¥ OF ANCHORAGE '~" ~'~' DEPARTMENT OF HEAL'FR & ENVIRONMENTAl_ PROTECTION  ENVIRONMENTAL ENGINEERING DIVISION [ ~ 825 L Street- Anchorage, Alaska 99501 Telephone264-4720 ON-SITE SEWAGE DISPOSAl. SYSTEM AND/OR WELL INSPECTION REPORT LEGAL DESCRIPTION Manufacturer LiE. ca }a~t~ Jrt.gal o ~ /~ IZ HOMEMADE: Inside length LWidth- Liquid depth I [ ~r blaterial Liquid capacity in gallons Top of tile to finish grade Length Type of crib DISTANCE TO: Class DISTANCE TO: Width Crib diamete~ Foundation Total len(.J.~t~o~ line.~.~ Materl~ ben"b'ath tile Depth Nearest Jot line Trench w['~'~Eh .- '~ '~ inches PERMIT N ~C~,~~ PERMIT ~O, Crib depth Total effective absorption area Well Building foundation Nearest lot line Depth Driller Distance to lot line PERMIT NO. Building foundation Septic tank Absorption area(s) OTHER PIPE MATERIAL~.~ ~)~ . . ~1 I_~E-ST RATINC) INSTALLER REMARKS Sewer line 72-013 (l~e~. 3~78) DATE LEGAL 1c, O~s~ance and Oirect~on ~rom Road Intersections ], OWNER O~ ~ELL: ~/~ S~A ~ o x 2, ~ELL LOG Fe~t BeJ~ Q, WELL D[PTH: (compJeL~) Surface Elevation Haterial Type Top Bottom /~ 3 Ft. ~ / 'ii ~ 8. FINISH 0¢ ~ELL: - ' ' ' J ' J . . Set b~t~en ft. and .... j J I0. PUNPlN6 LEVEL below land surface m r I1, WELL H~D COMPLETION: ~ In Approved Pit 12, G~OUTING: WeJJ Grou~ed: ~ Yes .... ,ater;.,: ~lNeat C~nt ~ Other: Type: ~ Subl~r, lble ~Rec Iprocat Jng g's~r~d Bu~ ~lama / Con'tact L~c~n~ ~umber L.L. Fi!F..li-I[...NI u H[::.HLI'H HI",[:, EN',,']F:rLd',IPET. TFI[ F'~',"'TEF'-"I~i,i /-~,b71 : ..,, ,:,.: .......... ........... ,_ ................ .. ' ......... ~ ", ,'..(!).;...'~ " 264-4;:'2E~ 'ri') .J'[..,..!I E::. L_ ~ .... ~::l~ft'...~E:, ,Z:~ll'-dl.---.".~ ~." '"[r'"E~". '.'iE;;EEIL.JIt[~":; F: 17 L~:]lf;,:..".lPli 'E "T' PE:.*:~:I"tI'I" t";tO. '" ,.,.LUJ.¢,:, I..j]r:'F:t'I'Z3NCRI','IPE:EL.L FfIR'Z';TF;:IP ROFIE:, L. EL'TJFIL. [.C"F J..:'L E~[...K :l. KNO~,~.OF THE 1.4OL[:, LOT ~;IZE 5',~',E.';O '.r.:;L:)LF4RE FEET 'T'¢PE OF SF-IL. FIE:':..:;OF-:PTION ::'"; :';"r'EH IS. TRENCH r,tF~;:.::'rh'.. _IH I'.,II...IhlBER FF'. BE[:,F.':OOM::..; = Z.": '.~;:' Z[. F.'.H I ........ I~',Ja' '::SI.'-:! F]',.'"BF,')= ]'HE REC.:IUIRE'I} E;IZE OF THE ':7:,OIL. ' ,,. ....... FIE,:, JF..f ] ION :.-:.;'T':E;TEr,'I Ir.=.;- THE LENGTH E) ZHENSZON Z::.; THE LENGTH ,:: IN FEET::, OF' TFIE TRENCH OF;.: E:,RFiINFIELJ}. THE DEPTH OF FI TRENCH 0,~ F'IT ZS; THE [:,I'_:;.,TRNCE BET.WEEN THE SUF::FRCE OF THE GROLIND FIND THE BO'FTOH OF: THE E,'.'.:;CFI'v'F:ITI ON ,:; I N FEE'I" ). 'TFIERE I2; I'-,10 SET .NI[:,TH F:'OR 'I'RENC:HE'5. THE ah.R E:I.... t'}EF'TH ]..:,"'"" THE M:[I"~II"llJH E:,EF'TH OF GF..H"' "-','El...' E:ETI,.IEEN THE OtJ"FF'FIL. L PIF'E FIN[:, 'THE E',OTT'OM OF THE E,,'~' '"_. -I" ,~H"F I ON ,' I N FEET). F'ERM.IT FiF'F'LICRNT FIRS THE F..E.._FIJi'~_,IE, ILIT~ T'O INFORH 'THI:5 [:,EPRRTHENT' E:,URING 'T'HE ~i: i",I'.'~.:;TI::IL..L.I::IT I 01'-.! I NSPEE:T I Cd",l:5 OF FIN'¢ IIE. LL:,'" '-' FI[:'..TFICENT TEl 'T'H I :.:~; F'F". F"Ef-..""F'T' FINE:, THE NIJHE~ER OF RE::2:]'[,ET,t.:':E':'L:; TFIFIT' ]'HE I,.!ELL .~'~IL.L. SEF.','E:. E:FtI.~:KFZ L.L. i NG OF F:tl",f~r' '"" '~ .... ,' '-" ......... ¢: !.:, !-::, !:;, - ,,,,¢', ::,'r..:,'lE. fl .WITHOUT FINRL II",I:,FE..f.[OI',I RI"~E:, .... .. - , ,",,... THIS I}EF'RRTHENT .t,.t:l: L.L. E',E /E;IjBJEi::T ']"l:} F'RC SE -:UT i EiN. HII',IIMLIH [:,I2;TRNE:E E, ETHEEi'., FI t-,.IELL. FIN[) FIN"r' F - , ::LI:~:F~ FEET FrOR FI F'RI'v'F:ITE HELL OR ':1 F'iFI 'FO - . ...... ¢:d,: FREE]" FROH FI F'.E:LIC I.,.IELL [:'EF'FNf')ING UF'IEII',I "FHET'T'I::'E IZIF' F:'UEiL_ I C I.,~!ELL. "" HINZHUi'"I [:'IST'FIN':E F:RI]H R F~.i ...... hie .NELL TO FI F'F.:I'v'FFFE :SEI,E(I:::: L. Ii'.,IE IS '::'~ FEET FIND TO FI COHMUNIT'T' SEI,.!ER L. INE IS "5 FEEl'. ...... .t,HEL..L. [.17r:i'~ .... :RE RE~!UIREC, FtN£:, MLI:.'.ST E~E F::ETLIRNED TO THE LE:FI-..F,.""" ...... HEI'. F F.IlTHIN :'2:El [:'R"r'i~:; OF THE I,.IELL. CI]HF'LETION. I:]THEF,' RI.:.:C.~. ]'REhIENTS HFI'¢ ': '" '"" -.. I-IFFL.~. £":;PECIFICFITI'.]N'5 FIN[)CON2;TF.':IJCT:J[FIN E:,IFtl3RF:IH'.::; FIRE FI',,,'FIII...FIE',L. Ei: TEl ]:i',I'_SLIRE F'F,_FER" '" ]" * '" .tN'-:::TRLLRT]:ON. .l: CERTI'F:'T' THRT :'L: I RM FRHIL. IRR 14ITH ]'FIE RE6!UIREHENT':-: FOR ON-SITE b]ENERS RN[:' I,.IELLS R2; SET FORTH B"r' THE MUN :1: C I PI'":]L I T"r' OF BI",ICHORFIGE. ;2: I NILL II"4::.;TFIL. L THE S"r'STEM IN RCCORE:'RNCE [,-!ZTH T'HE CO[:'EB. ::~:: i UNDERSTFIND TFIFIT ]'FIE ON-'.SITE 'SEI,.tER S¥S'T'EM HR"r' RE6¢JIRE ENL. FIRGEMENT IF' T'HE RE?7, IE:,E;',ICE I:~; REHOF;,ELED TO INCLU[:,E MORE THRN ]: BE[:'ROOH.S. ? / / / Dczp t h 15 0 Mo . Yypo of Dry ~,.~ml.,] c Skrc. ncith Group 4.0 ~t B SM Location: BESSE, EPPS & F<~i~ES 2220 EAST 88 AVEI~UE ANCHORAGE, AK 99507 (907) 349-6451 WATFA/ ~ELL TEST Subdivision: , '~,~ .~ ~._ Lot: _ Block: Client's Name: Address: Tes bet: Initial Reading c~ Meter: GPM 24-11our Carxuci ty Ca licn~ T,~; ii i,q, ! / DEPT. OF EN*IRONMENTAL CONSBRVATION / ANCHORAGE/WESTERN DISTRICT OFFICE / 437 'E' STREET, SUITE 303 ANCHORAGE, ALASKA 9950i BILL SHEFFIELD, GOVERNOR 274-2533 February 4, 1986 Besse, Epps & Ports 2220 East 88th Avenue Anchorage, Alaska 99503 SUBJECT: Lot 11, Block 1, Knoll o? the Wold Subdivision Anchorage, Alaska (8621-FA-104) Dear Sir: The Department has reviewed the Engineer As-built plans For the subject project. Final approval is hereby given For the water system and the "Certificate to Operate" is attached. Any Future expansion of the subject project uill require additional approval From this office. Sincerely, Michael P. Leuis Environmental Engineer MPL:pkk STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION CONSTRUCTION AND OPERATION CERTIFICATE for PUBLIC WATER SYSTEMS Ac APPROVAL TO CONSTRUCT Plans for the construction or modification of [] approved, // /~' {J~"~ ?~ f,/¢ -/~/~ublic water system located Alaska, submitted in accordance with 18 AAC 80.100 conditionally approved (see ~ conditions). have been reviewed and are 8Y TITLE DATE If construction has not started within two years of the approval date, this certificate is void and new plans and specifications must be submitted for review and approval before construction. APPROVED Change (contract order no. or descriptive relerence) Approved by Date C, APPROVAL TO OPERATE The "APPROVAL TO OPERATE" section must be completed and signed by the Department before any water is made available to the public. The construction of the //~u'c' ,~./J c'¢;/J-'- public / water system was completed on J ~'-/~/' -~/~;__ //¢'// (date). ']'he system is hereby 9ranted interim approval to operate for 90 days following the completion date. BY TITLE DATE As-built plans submitted during the interim approval period, or an inspection by the Department, has confirmed the system was constructed according to the approved plans. The system is hereby granted final approval to operate. /¢,, j BY TITLE j DATE 18~407 (Rev. t 1/83) DISTRIBUTION: 1, WHITE I ENGINEER (Complete Seclion C) 2. YELLOW - WATER SYSTEM EILE (Complete Section C) 3. PINK - ENGINEEPJMUN[.BOROUGH (Comrete Section C) 4. GOLDENROD - MUNI.BOROUGH ICornplete Seclion A) Application Date GENERAL INFORMATION c , ubdiViSiOn, section, townshiP, Locauon t~u~'~ '/~ /~ x /~ - /~ //¢~ ~~%elephone:.Ho ApPlicant Namely ~¢~ / g~- (b) Applicant Address ' 'Y ¢ '¢ ' (c) Applicant is (check one): Lending institution ~; owner/builder~ Lending institutiOn ~ Address (e) Rea~ Estate Company and Agent ~ Address %elephone ¢) Mail the HAA to the lol~owin9 address: TYPE OF RESIDENCE Single-Famib ~' Multi-Famib E] other Number oi Bedrooms ~ WATER suPPLY ~ individual Well ~ CommUnity ~ publ Note: I1 commUnitY well system, must have written attesting to the lega~ity and status. confirmation irom the State Department ct Environmental ConservatiO~ SEWAGE DISPOSAL Holding Tank ~ Onsite~' public ~ community ~ " Note: (t community well system, must have written confirmation from the attesting to the legality and status. State Department oi Environmental C°nservat~ paqe 1 o'i 2_ ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AN[;) INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on t he d ate of ?¢J.sqRs~ti.o.n, NameofFirm ~.~.~.._..¢- ~¢-~_.~7% .._4 ~"~x~'~--¢-, Telephone Address _~',x¢~O ?~-.-.¢%~-- ~-¢~ ~ ./&, Date /~-/~-z'~ ~' ~ /x.¢/~ ¢ Engineer's Seal DHEP APPROVAL ~'~ ~,,,',1 /¢~"~~ Approved for ~..~ bed room s b~ ~"--~~¢''~-~ Approved ~ Disapproved Terms of Conditional Approval Conditional CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued, The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-o25 (11/84) MUNICIPALITY OF ANCHORAGE (MOL/ HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: WELL DATA Well Classification Well Log Present~7)N) Total Depth Static Water Level Casing Height Above Ground Electrical Wiring in Conduit~l) Separation Distances from Well: To Septic/Holding 'Tank on Lot _ Cased to If A, B, C, D.E,C. Approved(~4) Date Comp/leted ~-¢"~--~/ - ~"*// Yield Depth of Grouting Pump Set At // Sanitary Seal on Casing~¢~l) Depression Around Wellhead (Ye ; On Adjoining Lots To Nearest Edge of Absorption Field onL/gt .~"~ /,' On Adjoining Lots To Nearest Public Sewer Line ~'~/~,~,,/¢ To Nearest Public Sewer Cleanout/Manhole ~/r' To Nearest Sewer Service Line Water Sample Collected by . /.~ .~f-~,~ ; Date Water Sample Test Results ~:~ ~/.~ ~ ~ ~/~ Comments ¢~ ~4~ ~'b%b ~ / B. SEPTIC/HOLDING TANK DATA Date Installed Standpipe~N) Air-tight Caps~N) Depression over Tank Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/~Hold~g Tank: To Water-Supply Well .,"~'~ To Property Line ~zj~, Course Comments ~fJ~b~ ~k//~ ~'-~' '-~/ Size /'~o¢, No. of Compartments Foundation Cleanou~) Date Last Pumped ~ ; for ~ - Temporary Holding Tank Permit (Y/N) To Building Foundation //'~ / To Disposal Field To Stream, Pond, Lake, or Major Drainage Page 1 of 2 72~026(11/84) ABSORPTION FIELD DATA Soils Rating in Absorption Strata/j¢/"-¢ ~ ~c*-XCType of System Design Date Installed Width of Field Square Feet of Absorption Area Depression over Field (~ Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well / To Building Foundation Lot ,~¢ ~-¢"~ / ~'7~-~--'7 To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments Length of Field Depth of Field Gravel Bed Thickness Standpipe~ Presen~N) Date of Last Adequacy Test To Property Line To Existing or Abandoned System on /'/ ; On Adjoining Lots -:~-~'~'¢ To Cutbank~n.n.n.n.n.n.n.n~resent) .¢"' -"~¢~-~ -;"' ~o~,~'%'./--,--,' / ~ /~/¢t%o4q-oH F~e~oPR'" ACC oN¢./7'¢ ~,~'-K/¢'~ Pb.F~m~7'- D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed /~'~,¢' *-~., //,"~/~-~¢ Date CompanyZ.-~?/¢:¢~ ~,'~ ~/~"?~-_s MOA No. .· Receipt No. "~-~b (,~o Date of Payment ,-~ - (J~ -- ~ ~. Amount: $ (Lb~~'O'-~ Page 2 of 2 72-026 (11/84) A4'Home -Services 15900 Francesca Drive Anchorage, Alaska 99516 345.1890 · 27'6.7161 L_ _j '~'"'~ ," "" -~"K DATE DESCRIPTION 'CHARGES CREDITS BALANCE PREVIOUS BALANCE .~ If th~ statement does no t agree w/th your records p/ease not/fy us at once. S TA TEMEN T DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME~ DATE DATE DATE INSPECTOR I NSP ECTOR INSPECTOR MUNICIPALITY OF ANCNORAGE MUNICIPALITY OF ANCHORAGE DEFL OF H&%rR  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL PROfECTION 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL SANITATION DIVISION OCT 1 Telephone 264-4720 DIRECTIONS: Complete all parts on page 1, Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE MAI LING ADDRESS -1~_~o ~on4r. aq~)~ C/~r~oto, hnch~e_~S¢, [~\/c. PROPERTY RESIDENT (if different fr~ ebove) PHONE Z BUYER PHONE MAILING ADDRESS 3. LENDING INSTITUTION I PHONE~ A }~; i(_~ (~ ~17(,,_,~ )I ;g79 MAILING ADDRESS 4, REALTOR/AGENT [ PHONE MAILING ADDRESS 5. LEGALDESCRIPTION LeT' STREET LOCATION ~. TYPE OF RESI~CENCE NUMBER OF~BEDROOMS [] One [] Four ~'¢JzE[' SINGLE FAMILY ;~i;~.' Two [] Five [] MULTIPLE FAMILY [] Three [] Six [] Ofher 7. WATER SUPPLY ~ iNDIVIDUAL* -~ ,O ~'J"'~" * ATTACH WELL LOG. A well log is required for all wells drilled ~'""'~'-"~ '/~"'~' ~ ' since June 1975, For wells drilled prior to that date, give well [~ -PUBLIC UTI LITY ~ depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE~ [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATE[). i THIS SIDE FOR OFFICIAL U~gE ON LY ~ 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS ~/ SINGLE FAMILY [] ONE ~"'"THR EE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [~] INDIVIDUAL DEPTH OF WELL [~COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED PERMIT NUMBER AGE DISPOSAL SYSTEM VIDUAL/ON -SITE DATE INSTALLED []PUBUC UT, UTY 7 Connection Verified INSTALLER eptic Tank or E~Holding Tank Size:_,/Ol'J~ . If Tank is homemade SOILS RATING give dimensions: TYPEOFTANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5, COMMENTS [] CONDITIONAL APPROVAL (letter must accompany certificate) -~ [] DISAPPROVED NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. SOUTHCEN I-RA L REGIONAL OFFICE June 4, 1981 Larry Langston 211 W. 7th Anchorage, AK Subject: 437 E. ST'REET S£CONO FLOOR ANCHORAGE, ALASKA 99,50I (907) 274.2533 P.O. BOX 615 KODIAK, ALASKA 99615 (907) 486.3350 P.O. BOX I207 SOLDOT'NA, ALASKA 995~ (907) 26'2-5210 P.O. BOX 170,° VALDEZ, ALASKA ~9968~ f907) 835,4698 P.O. BOX 1064 WASI£L,A, ALASKA 99687 (907) 326-5038 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL N-,OI ECTION 99501 t 0 1981 Lot 10, Block 1 Knoll on the Wold SD Contaminate separation Waiver Request Anchorage RECEIVED Dear Mr. Langston: We have reviewed the report and recommendations submitted by the Anchorage Municipal Department of Health and Environmental Protection concerning your request for a reduction of the Class "C" protective radii for your water system. We hereby grant a waiver of 18 AAC 80. 020 which requires a minimum separation distance of 150 feet between a class "C" well and a septic system to 140 feet in regards to the subject lot. If you have any questions concerning our review of this project, feel free to contact me. D.H.E.P. 825 L Street Anchorage, AK 99501 TLM/bab