Loading...
HomeMy WebLinkAboutKASILOF HILLS BLK 7 LT 25 GREI,,ER ANCHORAGE AREA BOR ,JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 NAME ~4 LOCATION INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM IvlAN U FACTU R E R~'%_ INSIDE WIDTH SEPTIC TANK: DISTANCE INSIDE LENGTH _~g~/~ NUMBER OF ~ MATERIAL ..... COMPARTMENTS ~ C APAC I TV/~'~(~G A L L LIQUID DEPTH LIQUID _=___ ONS. TILE [)RAIN FIELD: DISTANCE FROM WELL/~~') ( / TOTAL LENGTH , ,~ r FOUNDAT,ON/¢t~ NEAREST LOT L,NE /6) OF,_,NES ~O ABSORPTION AREA ~'L/~~ SQ. F-r. LENGTH OF EACH LINE ¢~ ' DEPTH: TOP OF TILE TO FINISIt GRADE ~ / DEPTH OF FILTER ~' MATE~A. SEN~AT, T~EE ~_~OVE T~.E ¢ ~. TyP~;~/"¢-__(~ ~ CONST BUILDING NEAREST FOUNDATION____ LO]' LINE . __ CEESSPOOL APPROVED DISTANCES: OTHER SOURCES DISAPPROVED RUCTION .......... DEPTH NEAREST SEPTIC SEEPAGE SEWER LINE TANK .... SYSTEM . DISTANCE FROM: REMARKS _ _ DIAGRAM OF SYSTEM INSTALLED BY: ~ SEWER LINE DEPTH: LOT SLOPE'. REMARKS: ' ' !I :'::::: .::: · : r.' ~!-'.,!1 . -~ r I~' ii .:." '"il i' ::ii ii,;?: ii'"::ii :,,.,,:~ ii':"[ i' . ~! '.,,i:::: i:::" i.i!: :::: ,"i :: : '::I Fi. It:i:! !i , June 15, 1977 R & M No. 751175 Carl Ivey 6727 Old Seward Highway Anchorage, Alaska Subject: Percolation Test for Sanitary Sewer System Lot 25, Block 7, Kasilof Hills Subdivision Dear Mr. Ivey, At your request of June 10, we conducted a percolation test on the above described lot. The test was conducted in an existing test hole which had been drilled to a depth of 22 feet. The hole was 4 ]./2" in diameter. Gravelly sand, which had been brought up by the drill, was present around the hole. The hole was initially dry to its total depth, with no water table present. On June 13, ].977, 55 gallons of water were put into the test hole. That amount of water did not fill the hole to a level where water was visible. On June 14, ]_977, the Staff Geologist returned to the site to find the hole dry to its total depth once again. Approximately 65 gallons of water were added to the hole at a rate of about one gallon per minute. Water was not visible in the hole after this addition, and the water level is not precisely known. However, rocks dropped into the hole could be faintly heard hitting water, and a measuring stick eight feet in length did not come into contact with the water. This indicates that the maximum water level was 14' above the bottom of the hole and the minimum level was 0'. Based on these approximations, maximum and minimum percolation rates can be calculated. In a 4 1/2" diameter column, 65 gallons of water is equivalent to 79.1 vertical feet. A maximum of 79.1 feet and a minimum of 65.1 feet perco- lated into the soil over a 65 minute period. This gives us a calculated percolation rate between 0.06 and 0.09 minutes per inch. June 15, 1977 Mr. Ivey Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions or if we can be of additional service. Very truly yours, R & M CONSULTANTS, INC. Stephanie Hoag Staff Geologist Jim McCaslin Brown PhD. Head, Earth Sciences Dept. SH:JMB/sl i¥o°~~ DEPARTED CAMP- AKRIVED FIELD DEPAB, TED FIELD ARrt, IVED CAMP_  XPLORATION SUPPLY AND EQUIPMENT, INC. c~ Drill Shift Report ~' DATE CONTB. ACTOR -- EQUIPMENT t~r~-g~-~- ~ UNIT NO. TRAVEL 'rIME KDOWN TIME MO V ' ' .... - CHARGEABLE TIME ~-~~'~ LOCATION FOOTAGE FORMATION DR, ILLER -~ HELPER ~'-~zzz ~OCK BiTS -- INSE~T BITS MUD USED TIME TIME APPROVF13 BY XPLORATION SUPPLY AND EQUIPMENT, INC. 6727 SEWARD HIGHWAY, ANCHORAGE, ALASKA 99502 PHONE 344-2589 March 22, 1978 Health ])epartment 825 I, Street Anchorage, Alaska 99501 Attn. Laura Dear ii, aura: Enclosed is the drillers log on the water well drilled February 18, 1978 £or Carl F. Ivey,. Xasilo£ _Hills Sub .Division, ]~ot 25 -~PP~q"~ 7. Thank you, Carl Ivey 6727 Old Seward Hwy Anchorage., Alaska 99502 MUNICIPALI]'y OF ANCHORAG~ DEPT. OF HI~ALI'F/ & ~NVIRONML:N I'AL PROTI~CFION $tl: XXX ~4UNICIPALITY OF ANCHORAGV DEPARTME, JF HEALTH AND ENVIRONMEN~ PROTECTION '~K~-2)I ],//! ' ~_~ ~ 825 L Street, Anchoraa~, Alaskai 99501 ~/J , ~ ~ 264-4720 ~- ~U ~ , ~,~l,-~3~",' ~-~ate Received: February 6, ri~ :~ ~,~ $2: T~me ~,' ~: T~me Date ~-7~7~ g~.3~} Date Date Insp ~na~ Insp ~ Insp 1978 REQUEST FOR APPROVAL OF INDIVIDUAL SE~ER AND WATER FACILITIES Lending Institution Request: First National Bank of Anchorage Mailing Address: Post Office Box 4-2090 99509 Phone: 274-1521/qL PropertY~-~ Mailing Address: Ca~l F./Nita L. Ivey NHN Sidorof Lane Phone 3. Legal Description: Lot 25 Block 7 Kasilof Hills Subdivision 4: Single Family Residence: (x) Multiple Family Residence: ( ) Number of Bedrooms: Five Number of Bedrooms: Well System: Individual Well (x) Community/Public System ( ) Permit # ~]LI~. Depth of Well Well Log on File Construction Bacterial Analysis Sewage Disposal System: On-site System (x) Public Utility ( Permit # '~q~l~. Installed 1977 Installer Septic Tank Size __/~ Manufacturer ~ Absorption Area ~O Soils Rate Material 7. Distances: Well to Septic Tank to Absorption Area to Sewer Line Nearesu Lot line Absorption Area to Nearest Lot Line Municipality of Anchorage DEPAR'~ .... £ OF HEALTH & ENVIRONMENTAL PR~,~ ~,;TION POUCH 6-650 ANCHORAGE, ALASKA 99502 279-2511 REQUEST I:OR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES 1. TYPE OF LOAN 12' ASSESSORS PARCEL NUMBER [] VA [] F.H.A. [] CONV []. 3. LENDING INSTITUTION 4. REALTOR OR AGENT First National BAnk of Anchorage P.O. Box 4--2090 Anchorage, Alaska 99509 none 5. SELLER 6. BUYER Carl F. &Nita L. Ivey none NHN Sidorof Lane Anchorage, Alaska 99507 7. LEGAL DESCRIPTION 8. LOCATION/STREETADDRESS Lot 25, Block 7 Kaseloff Hills Subs. NHN Sidorof Lane 9. TYPE OF DWELLING 10. WATER SUPPLY 11. SEWAGE DISPOSAL SYSTEM ~SlNGLE FAMILY RESIDENCE 5 BDRMS [] PUBLIC UTILITY [] PUBLIC UTILITY [] MULTI-EAMILY RESIDENCE BDRMS ~J<PRIVATE ON-SITF' [~cON-SITE 1977 YEAR INSTALLED INSTRUCTIONS TO REQUESTOR 1, Complete Items 1 to 11 above 3. Send to address above 5. Response wHJ be returned to lendin9 2. Remove the carbon 4. Please allow 10 days for processing institution DATE RECEIVED DATE OF INSPECTION TIME OF INSPECTION INSPECTOR TYPE DEPTH YEAR DRILLED PERMIT REFERENCE u~ FT, ~ CONSTRUCTION BACTERIAL ANALYSIS LAB REFERENCE NO. YEAR INSTALLED INSTALLER TANK SIZE MANUFACTURER ~ DIMENSIONS CRIB CONSTRUCTION ~- [] PIT >- ~- [] DISPOSAL TOTAL LINE LENGTH TRENCH DEPTH GRAVEL DEPTH ~ FIELD ~ FT. FT. FT. TOTAL ABSORPTION AREA PERMIT REFERENCE SQ. FT. 72-010 (11/76) Page Two Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 25 Block 7 Kasilof Hill Subdivision Con~ment s: Affadavit Attached~( ) Disapproved: Letter Attached: ( ) ]Date: Department Worksheet: