Loading...
HomeMy WebLinkAboutKASILOF HILLS BLK 9 LT 6Kas i* I of Hills Block 9 Lot 6 #015-131-07 Municipality of Anchorage Development Services Department*0 ;�? Building Safety y- Division On-Site Water and Wastewater Program. 1700 Bragaw St. P.O. Box 196650 Anchorage, AK 995196650 Page of ,aww.cl anchorage.ak.us (907) 313-7901 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWo:1009SPID Number: IS- 131-0 wa. RO b B,9c R MArly Wastewater System: ❑ New ❑ Upgrade Aao.sF .'D 110-49-3 Pao' ABSORPTION FIELD £Xif in hln of aed $ 3 Tata,swb O Do" 13 a Tlam ,O sea O uam O Oear LEGAL DESCRIPTION Sal Rawg Tolw DeM can aeano, eae q a"�0Mip1 Kaslo! Its so cFaFr' Dram bpw eonan rtan u,�W v.a C..w�o.w�es,nm Foe c,. TOwnaW Rrge Semon il. Fa aoMOe onFaa Watt,GreM Lagm Fl Well: f XfS }in ❑ New ❑ Upgrade Fl. a'Vi1Y n. wno«aw. ww .F...« r,.F GeeaMaian IF,enle A C) Toa Depen CaNa b Fl. TdN eawpea, aee Fl Poe W,ew Fl. Fl aMr F Do. D,aM Sta,x Waa Le,a FI YatrMdr /" [ I/an, Das amra E Strom, vw Fa,o SMa D+u,F Mey+/now C�vu,a l GPM Fl. n TANK SEPARATION DISTANCES 121Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Sank ADsorpuon Field Llh Holding udiWnvale Flom Tank Station Tank Sear Dna ague' r Anc Ttir11C W.F loo + � 5 ora Da oop unaw I wnw a canpaanan, � t a Q I s mwMe loo a LIFT STATION LM U" r 1 Ye imYH T � Fanaeem 10 1 T 'PunF On'Mwl al 'Punta aa' Mpn wMw Ywm at b a CV devl NO. F,.aF Ma46 feKarr byeOpq Falan,aa aY RemaAF BENCH MARK LPULun aq a.uye,,, Pitio Date " 1O0 FL ` 1,rj _ ters. Inspections performed by: J_Por An h fN Dates: 10 6 ZI 0 ".; pm fp Ap.q �� 1 2nd Development Services Department Approval �. Y `' 49TH,* Conditional Approval Date: 0 � 1..:..�� .. Reviewed and approved by:D-/$-t7 OFLjS���P- lae.w.,,n, ate: 1 I \1 1 � LOT 4 I I LOT 7 a C:) 1 N S 1 � ` 1 ABANDONED EXISTING `� I SEPTIC TANK PER MOA 1 I CODE REOU/REMNETS LOT 5 1 e 1 LOT 6 HOUSE 1 \c A A D INSTALLED NEW CD c 515' 50.0 1000 GAUON _ _ Q D 56.5'U5 SEPTIC TANK VAT a 0T I C 40.5' J9.5 F 4.L0' 42.0 / I 1 1 --—— — — — — —— L————— — — — — —— — ----- 1 �l / POND I-¢ Well / � NO1E5• / 1) NO WEL1S OR SURFACE WA MR WHIN 100'��� I 0r PROPOSED SEP17C TANK LOCAION LOT 9 ��E OF•44*� I 21 ALL WORK SNALL K PREFORMED DJ ••• • ••••••. ♦. ACCORDANCE WAN AMC 1165. G'�;.•....• • ,♦ J) 1611ERULS USED SNAU Or N ACCOROANCE � ,a. • *71H HOSE SP anrD N AMC 15.61 49th • •••LAR SPURKLAND•• t11�.;J1111111111 11111111111� �= � f% No. CE-usoo (� i 25 0 25 50 75 107 125 150 / .� •. �" 2O•'•••i SCALE, 1' = 50 FT. ... •••• o SPURKLAND ENGINEER/NG KASILOF HILLS BLK 9 LT 6 SEPTIC SYSTEM ASBUILT 203 W 15TH. AVENUE ANCH. AK. 99501 ROBE BAERMAN DATE.• JULY 2, 2007 907 279-3916 10710 VAS/KOF PLACE SKEET. 21J GRID: 2541 PERMIT r/ SV07O095 PID # 015-131-07 Ka silo fHillsB9L6BI.dwg SEPTIC TANK REPLACEMENT DETAIL DOUBLE CL£ANO"'" CONNECT £X1ST BRAB1 4+ FEET COVER 1000 901, septic tank ' 49th SPURKLAND BENCH MARK BOTTOM PATIO DOOR JAM ASSUMED ELEVATION 100' t GwNIIVLLKIIVU I I KASILOF HILLS BLOCK 9 LOT 6 I 203 W15th Ave SEPTIC SYSTEM DESIGN Anchorage Ak 99501 ROBB BARMAN DATE, �aJ[ 6, 2007 10740 vAMlKor putt SHEET 2/2 GRID 2511 PARCEL ID / 015-131-07 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW070095 Legal Description: KASILOF HILLS BILK 9 LT 6 Design Engineer: 0007 SPURKLAND ENGINEERING Owner Name: ROBB BAERMAN Owner Address: PO BOX 110743 ANCHORAGE. AK 99511-0743 Date Issued: Jun 07, 2007 Expiration Date: Jun 06, 2008 Parcel ID: 015-131-07 Site Address: 010740 VOSIKOF PL Lot Size: 42249 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. - (EMERGENCY TANK REPLACEMENT) - SEPTIC TANK INSTALLATION MAYBE LOCATED NO LESS THAN FIVE FEET FROM ANY PROPERTY LINE OR BUILDING FOUNDATION; TEN FEET FROM ANY WATER SERVICE LINE; ONE HUNDRED FEET FROM ANY SURFACE WATER; AND ONE HUNDRED FEET FROM ANY PRIVATE WELL; AND THE SEPARATION DISTANCES REQUIRED BY 18AAC72 FROM WATER SUPPLY WELLS. Received By: "`' Date: 6 7 Issued By: ��. _ Date: i7 1 Municipality of Anchorage (• -� Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519.6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. nI Vi - (3l- 0__J- Property owner(s) Rob SAOr11'1an Day phone 3Y6- 1303 Mailing address PC), QoX IIDT43 , Ancllomq,,_ Ak 99511 Zip Code Siteaddress ID340 VzsiI`o( Place. Zip Code Legal description (Sub'd., Block & Lot) bsilof Iiil'S Bpi, 9 Lo{ G Legal description (Township, Range & Section) Lot Size t19 -I'm Sq. Ft. Number of Bedrooms 3 j!�7't 0720 9Jc77-)/-J THIS APPLICATION IS FOR (® all that apply): THIS APPLICATION IS AN: Absorption Field ❑ Initial ❑ Septic Tank 19 Upgrade 0 Holding Tank ❑ Renewal ❑ Privy ❑ Private Well ❑ Water Storage ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees:Waiver Fees: Date of Payment: Date of Payment: Receipt Number. 9 7033 Receipt Number. (Rev. 11105) 0 :` Environmental Consulting and Design June 6, 2007 Municipality of Anchorage Development Services Department Building Services Division On-site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Subject: EMERGENCY SEPTIC TANK PERMIT APPLICATION KASILOF HILLS BLOCK 9 LOT 6 We are submitting an application for the replacement of the septic tank for this lot. The existing septic tank has collapsed and the house is with out sewer service. The submittal consists of two (2) drawings showing the present improvements on the lot and the proposed improvements of the lot, of which only the septic tank is subject to this permit application. There are no wells within one hundred feet of the proposed replacement site. The installation of this septic tank will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses within 100 feet of the proposed septic tank location. The proposed septic tank will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or are in need of additional information please contact me at 279-3916. Lnc.ercly, s Spurkland, P.E. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (907) 276-6013, SpurklandEng@gci.net 1 I 1 LOT 4 ► LOT 7 1 ABANDON EXISTING `�` ► SEPTIC TANK PER MOA 1 1 CODE RfOUIREMNETS LOT 5 �C O 1 ► :, O I � � I LOT 6 LTJ HOUSE 1 ► INSTALL NEW #ell S ► 1000 GALLON _ Q ' I S£PAC TANK I NA ttr1' I � Liar s� �C � ► 1 � ► 1 lY I I Well NOTES 1) NO WE115 OR SORFACE WATER WAHI11 100• I 0< PROPOSED &TW LANK LOCATION 2) ALL WORK SNAIL K PREFORMED AN ACCORDANCE WAN AMC 15.65. 5) MATERIALS IUD S/14U BE W ACCORDANCE w9TN moor SPEano IN AMC 15.65. 25 0 I 25 W 75 100 125 150 SCALE, I' = 50 FT. LOT 9 "pi c: 4 ' 49th �...L ......... =... i. �„ 7 '�R y LARS RRn;IK f C / ♦ o No. r usao ti 2 V.�W 15 . AVE [Ruvtr KASILOF HILLS BIX 9 LT 6 SEPTIC SYSTEM DESIGN 103 W 15TH. AVENUE ANCN. AK. 99501 ROBB BARMAN DATE: JUNE 6, 1007 907 279-3916 10740 VASIKOF PLACE SNfET 2/3 GRID: 2541 PERMIT 9 0., _ __ SEPTIC TANK REPLACEMENT DETAIL DOUBLE CLEANO"'^ CONNECT EXIST DRAlh..__ /— 4+ FEET COVER ! uuu yu I, septic -conm FOUNDATION CLEANOUT 20 URIC 5th Aveuirvccrcirvv KASILOF HILLS BLOCK 9 LOT 6 SEPTIC SYSTEM DESIGN 203 orage AR098 RAERMAN DATE, JM 6 2007 Anchorage Ak 99501 a79-99lA 10740 VASIKOI PUC£ SHEET, 2/2 GRID, 25+1 PERMIT / PARCEL ID / Kasila/NillsBA6.dwo 1 Environmental Consulting and Design Single Family On-site Wastewater Disposal System Construction and Material Specifications Subject Property: Kasilof Hills Block 9 Lot 6 Date: June 6, 2007 General: 1. The owner shall contract with a contractor to perform the work outlined in these specifications and plans in accordance with the attached MOA permit. There is not contractual arrangement between the contractor and the Engineer. The Engineer shall be the owner's representative and will Inspect the work to document the contractors activities. Final acceptance of the contractors work rests with the owner and the MOA. 2. The scope of the work includes the installation of a new 1000 gallon septic tank. The location of the drainfield is shown on the attached site plan drawings. All components of the proposed septic system must be constructed a minimum of 1D0 feet from any surface water or water wells in the area. A minimum of 4 feet of earthen cover is required over the septic tank. If less than 4 feet of cover is available, 2 -inch thick, 40 psi, direct bury board foam shall be installed directly over the septic tank and all Installed piping. 3. Construction shall be in accordance with the approved site plan and design drawings and any special provisions noted on the Municipal well and/or septic permit. All materials, components, workmanship and construction practices shall comply with the Municipality of Anchorage's latest ordinances regarding wells and septic systems, as well as MOA, Development Services Department, On-site Water and Wastewater Program (DSD) policies. 4. The contractor is responsible for obtaining all underground utility locates, layout of the proposed system, and verifying and maintaining all required separation distances to lot lines, surface water, wells, steep slopes, etc. 5. The property owner shall be responsible for final grading any depressions formed from settlement of backfill material. The property owner is also responsible for vegetation of all areas disturbed by septic system installation activities. 6. Contractors installing wastewater disposal systems must be certified to do so by the MOA DSD, On-site Water Wastewater Program. Property owners installing their own systems must receive advanced approval from MOA DSD prior to system installation activities. 7. The contractor shall ensure that ALL materials being used are in compliance with the most current guidelines established by the Municipality of Anchorage. Refer to "Standards and Specifications for Component Parts and Materials Used In the Construction of On-site Wastewater Disposal Systems", Dated December 2000, as provided by MOA DSD, On-site Water and Wastewater Program. 203 West 15'" Avenue Suite 203, Anchorage, AK 99501, phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland(_agci.nct '= 11R,pa��U�a�d Environmental Consulting and Design Septic Tank Installation: 1. A new septic tank, of the size specified in the design drawings, shall be procured from a qualified manufacture/supplier If the existing septic tank is found to be defective. Construction shall include two 4" diameter cleanouts; for pumping access. 2. The burial rating of the tank shall be adequate for the actual burial depth encountered. 3. The tank shall be level and sufficiently bedded to prevent settling of shifting of the tank. 4. All standpipes on the tank shall extend a minimum of 12inches above the final grade. S. Tanks installed with less than 4 feet of cover shall be insulated. 6. The sewer service line from the house to the tank shall have a minimum slope of 2% unless prior approval is obtained from the engineer. 7. The inlet and outlet lines from the tank shall be bedded In drainrock or the soil shall be sufficiently compacted to prevent future settlement of the soil. S. Septic tank inlets, outlets and cleanouts shall be fitted with water tight couplings. 9. A deanout shall be Installed 1 to 4 feet from the foundation. 10. Post tank cleanouts shall be installed per MOA requirements. Does not apply to pressurized lines. 11. In areas with high ground water, the septic tank shall be sufficiently anchored to resist buoyancy forces when there is not adequate soil cover to resist uplift force. The contractor shall refer to the engineer for direction regarding this matter. 12. The tank backfill shall be graded sufficiently to ensure positive drainage away from the tank. 13. All holding tank and lift stations shall have an audible and visible alarm Inside the residence being served. 14. All lift stations shall be wired in compliance with all MOA guidelines and the Uniform Electrical Code. A municipal electrical permit and Inspections must be obtained where required by the MOA. 15. The contractor shall verify that the septictank/lift station is a minimum of 100 feet from any residential water well, 150' from any dass'C' well and 200 feet from any community water wells. Additional separation distances must also be maintained. 16. The contractor shall remove or abandon the existing tank in compliance with the Unform Plumbing Code. Inspections: 1. A minimum of one Inspections are required by the Municipality of Anchorage. These Inspections must be conducted under the supervision of a Professional Engineer licensed to practice in the State of Alaska. 2. The septic tank may be set in place, but may not be backfilled. 3. The contractor shall provide a legible copy of all field notes relating to system layout and construction to the engineer for the use in preparing the record drawings. 4. The contractor shall coordinate all inspections with the Engineer. A minimum of 24 hours notice is required prior to the start of construction. If necessary, a preconstruction meeting will be held on-site. 203 West 15'" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net c . GREA- R ANCHORAGE AREA BORT 'GH Department of Environmental Quality �m y% 3330 C Street Anchorage, Alaska 99503 _ INSPECTION REPORT ON-SITE SEWAGE DISPOSAL. SYSTEM ,� NAME "�''/(J %YJy�t /MAILING ADDRESS �i% ��i 47' lelaMl "!/ PHONNEE 71? '/S' LOCATION U C/ �C t/*//, � C� LEGAL DESCRIPTION /K % /`�S�` 0-r SEPTIC TANK: , ✓ DISTANCE C) � �_� NUMBER OF FROM WELL MANUFACTURERS MATERIALS i �tr'� COMPARTMENTS / �Z X16 7/// INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY 000 GALLONS. SEEPAGE PIT: t NUMBER OF PITS / DIAMETER OR WIDTH, LENGTH!! DEPTH LINING MATERIAL (�2r1C62LZ_ CRIB SIZE: DIAMETER DEPTH DISTANCE FROM: WELL Z/ �OTAL EFFECTIVE %!/// BUILDING FOUNDATIOI\Itw�, NEAREST LOT LINE Z5 Tb� ABSORPTION AREA (WALL AREA) `7 7 SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE CONSTRUCTION DEPTH DISTANCE FROM: BUILDING NEAREST t NEAREST SEPTIC SEEPAGE FOUNDATION w��LOT LINE 10 4oIF, SEWER LINE—_TANK/t&_, SYSTEM CESSPOOL -- OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: PIPE MATERIAL: ° 5r�IL LOT SLOPE: / ['i�/r� REMARKS: ��C" Fnrm Nn Fo-n91 GREATER ANCHORAGE ARCA BOROUGH DEPARTMENT OF ENVIRONMENTAL OUALITY PERMIT NO. �. 3500 111UOR ROAD E'OUCH r, 550 A::CTHORAGE. ALASKA 99502 TEi.1:PHONE 2.79-C60P SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT NAME OF APPLICANTLl�'I v ✓'+--1-+-------1,1 6 --- MAILING A/UUF F55 �_1.'_. �'�}.---� J PHONE INSTALLATION LOCATION J`--1Zf= 1 ("� }• `-�.V�j ��"d'�7 1 f LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK I --- SEEPAGE PIT ORAIN FIELD OTHER TYPE AND SIZE OF FACILITY TO RE SERVED {- ' TO BE INSTALLED BY f � 1 I ( SOIL TEST RESULTS'-� J l` 17('/��7C�1/l'Z NOTE, THIS PERMIT IS NOT VALID WITHOUT SOIL TF57 COMPLETION DATE ANTICIPATED —' _ PFRMTT VAl.IL1�lI�F YEAR - - FINAL INSPECTIONI 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HKALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. % `//1 1 PS X (, (,'%<- TYPE SEPTIC 'TANK SIZE _ TYPELit-G'. °i1_Drconn 'P.t PSEEPAGE AREA SIZE MINIMUM DI$TAREQUIREMENTS DIAGRAM OF SYSTEM 5 ft, FOUNDATION TO SEPTIC TANK �s MJf•E FOUNDATION TO SEEPAGE PIT GO ft, DRAIN FIELD 1.0 ft, SEPTIC TANK TO SEEPAGE PIT WALL 15 ft SEPTIC TANK _—ftt SEEPAGE PIT 20 ft, . DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD SEEPAGE PI'I —.— ' ALSO CONSIDER AREA WELLS, WATER MAIN TO SEPTIC TANK 10 ft• SEEPAGE PIT 10 ft DRAIN FIELD --- 0ft• -_. SEPTIC TANK, 25 ft*, SEEPAGE PIT _100 C,r� ft0 , DRAIN FIELD � ft, 4" CAST IRON SIPHON SUPT IC PIPE WITH AIRTIGHT CRIB I AN 1; CAPS EAS, IRf:� . 4 5'..a MOND: CAST IRON _ — INTO UNDISTCCDED SOIL:'��s III II I MUI1 C I required vhenever line crosses under Jrivea y. TO RIVER. LAKE, STREAM. I❑H,I":III I!1I, rn rA.rr- zoo' AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF r oo' CAST IR014 INTO II':'P")DAL EXCAVATION S FEET INTO UNDISTUR13ED SOIL. 10 PI1- 100' I,0 %il1:R LIN[- 10' CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT A INCH DIAMETER „Li- POULIC FITTED WITH AIRTIGHT REMOVABLE CAPS. 111 TAP;!:- PC" T^ If T- 170' I;0 •.!; Ip IIS(- 40' 40' M,' O1!1.'r GRAVEL BACKFILL EA',: )ION SE:IER I. Fur CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. P11H IC rn rA.rr- zoo' r oo' ' 105'-;I �.O' n-tls. .P.` r I:'ca SEUEI: Iris-. ry9 S111!rCC NP HEALTH AUTHORITY OR LICENSED DESIGNER RAVEL FA44KFILL AROUNDCk1o. a,DIfINII;UN A.BOs'E WATER TABLE) 4 11101 SEVER LHic. CONSINIZ ARE!. RELIS. SLEPAGE I'll EXCMATIOH BASED ON 5011. HEST. y£LL'ao Grade: i.Por 'GO' or 1/4' P r foo: except 10' precredinq tank d tha. shoold I not exceed 21. j 6' per 100 on flat terrains. CAST Ir011, .7 SEPTIC T1111 / IGICI nl IT PGEn/—) CAST IRON SIPHON PIPE SOIL ; .� —CRIB PIT F - / CAIB _ I GRAVEL BACKFILL �r i ' 20' HINIMUM IIf AP E ST t 0 T LIIIF___�r I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE: AREA BOROUGH ORDINANCE NO. 28-66 AND THAT THE AE3OVE DESCRIBED SYSTEM 15 IN ACCORDANCE WITH SAID CODE. //,J/ P pNOlonncC� rr x W V1E L� � I e96o` o >I 4H/ZEO JPN//\' GREATER ANCHORAGE AREA BOROUGH 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 December 4, 1972 DEPARTMENT OF ENVIRONMENTAL QUALITY Glenn Smith P.O. Box 4-1444 Anchorage, Alaska 99509 Subject: Permit to install sewer system Dear Sir: C��� �REATEDF gryY AONM I'ITA6 G1U �11Y11 BKPT• A permit was issued to you by this Department for the installation of an on-site sewer system and at this time we have no record of this system having been installed. Please complete this form and return it to this Department at your earliest convenience. yes no F] 1. The system has been installed. 2. The system will be installed later this year. 3. Void my permit; the system will not be installed. �I 4. The system will be constructed during the next construction season. Your cooperation is requested as we have a great number of outstanding permits for 1972 and we would like to clear our permit files out as much as possible. TN nk you, oe ohn R. Lee, R.S. Environmental Services Supervisor Coniftaetion gest Ya. "One test is worth a thousand opinions" 8829 TUDOR ROAD, ANCHORAGE, ALASKA 98807 9 TELEPHONE 333-8472 Performed For e /;/ry —`Date Performed � H�iB�e Legal Descrintion: Lot", Block`Subdivision__ This Form Renorts Soils Loo-- Percolation Test_ nenth Feet Soil Characteristics Si 5 A- 6,roruetis ckj C & to 5 — , F — SA�Vct`j 6esgWe 8— (,� ln yy Was Ground Water Encountered? V& If Yes, At what Depth? Read inq Date Gross Time Net Time Depth to H2O Net Dron1' Percolation Rate _Minute Proposed Installation: Seenaae Pit VeX Drain Field Death of Inlet Depth o Bottom Of Pit Or Trench�_BB C r) M M E N T S : / % :? '9^a_ 01 .O .r..® .ea. 094- n 9C �s. A6 iw . 11,r a Al PP%® e Test Performed By tz"? ®` oo C -/� Data Certified r . o MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date _ 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or direc�tioo s 1--e _27 6� p.a l i -`a (b) Applicant Name4241W 5.�°1i4V Te/le/phone: Business Applicant Address _ 4R'a" (c) Applicant is (check one): Lending Institution ❑ ; Owner/builderT; Buyer ❑ ; Other ❑ (explain); [a (e) (f) LendingInstitutip •fit �t'c:d �i'r f �� /l� �d d2fhone .3`� `�4 Address Real Estate Company and Agent Address Telephone Mail the HAA the following address: 2. TYPE OF RESIDENCE Single -Family Multi -Family ❑ Other Number of Bedrooms Z. 3. WATER SUPPLY Individual Well Pr Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11/04) 5. ENGINEERING FIRM PROVIDING, INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and requlations in effect on the date ( Name of Address Date, P_� Ju • 1. Corviin +� �> Engineer's Seal ' a CE -5283 0 �VErJ G 6. DHEP APPROVAL IC00 Approved fors_ bedrooms by J~t Cate Approved __.._ Disapprov Conditional 'Terms of Conditional Approval CAUTION . The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) MUNICIPA`t O OHEA HliORAGE MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) DEPT' pROiEcTtON CHECKLIST - FEBRUARY 1984 �NIRONMENTAI 2sa-a72o SO ba *85Legal Description, ��� � A A04� A. WELL DAJ(ECE•� ,- Well Classification d If A, B, C, D.E.C. Approved (Y/N) Well Log Present (Y�V��Date Completed — Yield er/ �� % A/ Total Depth-��Ss _ Cased to ` 7` Depth of Grouting '- Static Water Level - - Pump Set At -]!� y0 Casing Height Above Ground 9W Sanitary Seal on CasingY/ ) Electrical Wiring in Conduit J) Depression Around Wellhead (Y0155d — Separation Distances from Well: To Septic/Holding Tank on Lot G� ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot �` ; On Adjoining Lots 4 _ To Nearest Public Sewer Line To Nearest Public Sewer Cleanout/Manhole To Nearest Sewer Service Line on Lot � Water Sample Collected by t '- W%4�i' ; Date Water Sample Test Results Comments B. SEPTIC/MetOtt+G TANK DATA Date Installed —Size Xe:�WD No. of Compartments StandpipesY/ ) Air tigh e Depression over Tank (_ O Pumping/Maintenance Contract on File (Y/N) Holding Tank High -Water Alarm (Y/N) FouTidation Cleanout ( — Date Last Pumped�s i for Temporary Holding Tank Permit (Y/N) — Separation Distances from Septic/Holding Tank: To Water -Supply Well — l®s To Building Foundation To Property Line To Disposal Field -- To Water Main/Service Course i Comments _ Page 1 of 2 rA � '� To Stream, Pond, Lake, or Major Drainage if C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata ��/� Type of System Design Date Installed %— `% — ?:�S Length of Field � f Width of Field Depth of Field Gravel Bed Thickness Square Feet of Absorption Area �� Standpipes Prese q) lzesS Depression over Field ( /N) a nate of Last Adequacy Test Results of Last Adequacy Test Separation Distance from Absorption Field: To Water -Supply Well '7,"To Property Line To Building Foundation 3d _. To Existinggr Abandoned System on Lot d /res« ; On Adjoining Lots DO �— To Water Main/Service Line To Cutbank (if present) To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments — D. LIFT STATION Date Installed - Size in Gallons N/f "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Comments Iq ** Check P r itted ddW Dimensions Manhole/Access (Y/N) "Pump Off" Level at Rating Against HAA Request ** Vent(Y/N) Pumping Cycles during Adequacy Test. Meets MOA I certify t e eked,v rifie� , or conformed to all MOA and HAA guidelines in effect on the date of this inspection Signed / / Date 9 —��� 65;P Comp a MOA No. _ Receipt No. -4601 Date of Payment _ 7l2 Amount: $ �� S r c� Engineer's Seal 9 f ' C� .'� � a ;r co J. Corciin Page 2 of 2 � = Q,7 ; o o. CF -5283° �V c� 72-026 (11/84) CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. A%Xxn\L TELEPHONE (907) 562-2343 5633 B Street Anchorage, Alaska 99518 v ^•�^"° Drinking Water Analysis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIERI TO BE COMPLETED BY LABORATORY El PUBLIC WATER SYSTEM I.D.# ❑ PRIVATE WATER SYSTEM 'Name Phone No. Mailing Adyress City State Zip Code SAMPLE DATE: 1% � Mo. Day Year SAMPLE TYPE: �f Routine Check Sample (for routine sample with lab ref. no. ) ❑ Treated Water ❑ Special Purpose ❑ Untreated Water SAMPLE Time Collected NO. O ATI Collected By 1 rRsi/ OFic �s-�S �- 2 3 4 5 Analysis shows this Water SAMPLE to be. 01 Satisfactory ❑ Unsatisfactory ❑ Sample too long in transit; sample should not be over 30 hours old at examination to indicate reliable results. Please send new sample via special delivery mail. Date Received Time Received Analytical Method: Membrane Filter * No. of colonies/100 ml. Lab Ref. No. yo.5-7- )q3 BACTERIOLOGICAL WATER ANALYSIS RECORD READ INSTRUCTIONS Membrane Filter: Direct Count RLCGI�pC ~ Verification: LTB COLLECTING SAMPLE Final Membrane Reported By TNTC = Too Numberous To Count OB = Other Bacteria BGB Analyst -:15CL Coilform1100ml s Cpilfgrml100m1 Date V / �( / v v Time: �> L� a. M. ��I�j p.m. 678910 77 0 • � Municipality of Anchor.. MAY 0 9 2018 On-Site Water and Wastewater Progra ' \ (907) 343-7904 SAM',iF T. c Certificate of On-Site Systems Appro -' 6 8 L 9 Parcel I.D. 015-131-07 Expiration Date: Cm 10 , ,�0 I g 1. GENERAL INFORMATION: Complete legal description Kasilof Hills; Block 9, Lot 6 Location (site address) 10740 Vosikof Place*Anchorage,AK 99507 Current Property owner(s) Sharon Baerman Day phone Mailing address Real Estate Agent Bob Baer Day phone 261-7505 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank El Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: _ Distance: Received by: A Date: —O/8 COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ ,c2IO Waiver Fee $ Date of Payment 5 f/Q I ts Date of Payment Receipt Number OO ?2 Receipt Number COSA# .SP•19` 1� Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: .„,-:::5:,..s .....\‘, In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system , 01- 0� in accordance with the guidelines and regulations established by the Municipality of Anchorage and O ,.•••..• *.- S-A industry practices. The reported results describe the condition of the system/s on the date/s of the ' • 0 evaluation. Separation distances were measured to readily identifiable features. Hidden defects or D "' c Q encroachments may exist that were not identified during the evaluation. The operational life of all wells �•. 4 !'I'. I . v0 and septic systems depend upon a variety of variables, including but not limited to, soil conditions, 0) groundwater levels (that may fluctuate during the year), quality of construction (materials and I VA workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and �,.. . ..� are outside the control of GEG. Satisfactory test results do not guarantee future performance of the 00:30, �� A. or ,ess: system/s; therefore, GEG makes no warranty(express or implied) regarding the future performance of UQ�� . CE aS�G the well or septic system. GEG makes no representation whether an alternative well or septic system (,)1 s q.5 ce0can be installed on the property in the event either of the current systems fail to perform adequately in u4� �, .• .f& �Ao the future. The content of this report is for the sole benefit of the person/party that retained GEG to %Zed prp;ess��n0\�� perform the evaluation. Reliance upon the information provided in this report by any other person or ��00000��6 party (including subsequent property purchasers) is not authorized, nor will it confer any legal rigtt,. 01= whatsoever. C./ ? #AECC884 6. DSD SIGNATURE J ON-SITE `76, J System #1 Approved for 3 bedrooms Z• WATER AND '11 aril : System #2 Approved for bedrooms WASTEWATER o -kPROGRAM ,� Disapproved 'moo �` Conditional approval for bedrooms, with the following�slipul tons: e.p.- oI--i c \-ct A k tz Ciresl.,l,tc;k .t 5 t-LC cL --\-0r - I�Q 1 cc:a l',"\-' . t I U ra-20\1:.-t_.e C rl' JVD s,ze -Fv P 2 5 be c1c�1, (.e ctL w a l e"`1- \-0 .5 Pzv,_,le>- Sc e en c - v `�ck� S Ie-I�e1 Sor JuS'��'{-� Cc;� 1 �t� -\""[Nc`npcove ns bc8iz.,Cm Swhle.titi I . d By: 2L t.c ) �s�•itCO ��t Tr►, ��ltlu,� Original Certificate Date: 5 /1 /18 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: • COSA Checklist X Nitrate Advisory Y Septic System Advisory Arsenic Advisory Well Flow Advisory Other &i ci l''leer's I C I-fie r C) COSA blue sheet 10-10-12.doc • If more than 1 septic system is on the lot: COSA Checklist# of_ Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Kasilof Hills; Block 9, Lot 6 Parcel ID: 015-131-07 A. WELL DATA *Per MOA HAA Checklist approved on 9/26/1986 Well type Private If A, B, or C provide PWSID# N/A Well Log (Y/N) No Date completed 1973(?) Sanitary seal (Y/N) Yes Wires properly protected (Y/N) Yes Total depth *345 ft. Cased to Unknown ft. Casing height(above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test 4/17/2018 Static water level ft. 18.7 ft. Well production g.p.m. 6.6+ g.p.m. WATER SAMPLE RESULTS: Coliform Kee) colonies/100 ml. Nitrate 41•08 mg./L. Collected by: GEG. Ltd. Arsenic: <5 J ug./L. Date of sample: 4/18/2018 B. SEPTIC/HOLDING TANK DATA **Pre—tank double cleanouts Tank Type/Material Septic/Steel Date installed 6/21/2007 Tank size *1000 gal. Number of Compartments 2 Cleanouts (Y/N) Yes Foundation cleanout(Y/N)**No Depression over tank (Y/N) No High water alarm (Y/N) N/A Date of pumping 4/17/2018 Pumper ARM Services C. ABSORPTION FIELD DATA Date installed 7/9/1973 Soil rating (g.p.d./ft2o /bdr 173 System type Seepage Pit Length 16 ft. Width 15 ft. Gravel below pipe 7 • ft. Total depth *11.5+ ft. Eff. absorption area**434 ft2 Monitoring tube Yes Depression over field No Date of adequacy test 4/18/2018 Results (Pass/Fail) Pass For ** bedrooms Fluid depth in absorption field before test 16.5 in. Water added 761 gal. New depth 43 in. Elapsed Time: 120 min. Final fluid depth 34 in. Absorption rate >= ** g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) Unknown If yes, give date — A 2,066 gallon pre—soak was performed on 4/17/2018 *Below existing grade at seepage pit. A+ Home Services added approximately 24" of soil cover over the east half of the septic tank (4.41' total cover) and approximatley 21" of soil cover over the seepage pit (3.46' total cover) on 5/7/2018 **See attached letter D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at .• wa er alarm level at in. 1- - •• Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75 + Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain None Known Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATIONoo ,` OF AL... !`kph o Q• -. 4 00 I certify that I have determined through field inspections and Ai* 4 9 , •.9*O review of Municipal records that the above systems are in VA conformance with MOA COSA guidelines in effect on this 0 date. '0O % f r: A. orne- ;• Engineer's Printed Name JEFFREY A. GARNESS gh4,.;.. CE 779 3�p .. .\c�Qo Date r! D/(5 4OQaprofessloa`= °40000 #AECC884 (Rev. 11/05) MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT I • }!c.'uw 907-343-7904 On-Site Water and Wastewater Section Fax: 343-7997 www.muni.org/onsite Nitrate Advisory' Certificate of On-Site Systems Approval # 0SC181199 Subdivision: Kasilof Hills, Block: 9, Lot: 6 A water sample revealed a nitrate concentration of 9.08 milligrams per liter (mg/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. Mailing Address: P.0. Box 196650 *Anchorage,Alaska 99519-6650 *www.muni.org Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. __ Quanics GARNESS ENGINEERING GROUP, Ltd A°'' °T '"7=t 's""" CIVIL&ENVIRONMENTAL ENGINEERS Dea/er May 9, 2018 Municipality of Anchorage Development Service Department On-Site Water& Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: COSA for Kasilof Hills; Block 9, Lot 6 To whom it may concern: As discussed previously and overviewed in the attached email, the existing lot has a 2 bedroom drainfield (technically sized for 2.5 bedrooms) and a 1,000 gallon steel septic tank that was installed in 2007. On the 2007 inspection report and design, it states that the home is 3 bedrooms and was approved by the MOA. Based upon our conversations/emails, the MOA would approve a COSA stating the bedrooms the tank is rated for and the number of people the drainfield was approved for if it met the specified criteria (listed in the email). Our justification for proposing the COSA be approved for 3 bedrooms and 5 people is listed as follows: • The design for seepage pits is conservative in that it only accounts for sidewall area. In this case, there is also 240 square feet of bottom area that is also available for absorption. • The majority of the seepage pit sidewall area (434 sq.ft) and bottom area is in a soil rated at 150 sq.ft/bedroom. • As can be seen on the attached COSA paperwork, the drainfield was pre-soaked on 4/17/2018 with 2,066 gallons and an adequacy test was performed with 761 gallons (enough for 5 bedrooms) on 4/18/2018. • On 4/18/2018 the liquid level started at 16.5 inches, rose to 43 and dropped down to 34 after being allowed to recover over a 120 minute period. If you have any questions, please contact us at 337-6179. Thank you for your assistance. :Incerely, e r:y 'I. carn=ss, P. ., M.S. Pre •e t 3701 East Tudor Road, Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com Jeff Garness From: David Harper <dlharper2@gmail.com> Sent: Monday, April 23, 2018 11:35 AM To: Jeff Garness Subject: 10740 Vosikof Place Jeff,the well located on the above addressed property, has been brought up to the MOA requirements as needed as of this date. 4-23-18. Sent from my iPhone 1 i 41 N e.» 10 • IN ‘17r3i r - ) •� 1 Ot + I I S INCE rAMILY I A TRATE HIX)$C j • / 1 CPQ 1 Vr�ll�N1Ir - - 'vCLL e'AF Sc ' I o j' I� ' In 8 JO'UJILITT EASCNCNI T,T1 54•SYv 100.00 50' T' AT-BUILT SURVEY i" a )Q1 No COMMIS INT 005 PATI I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY _-OF A•I,' OF THE FOLLOWING DESCRIBED PROPERTY �'I LW6. BLOCK 9. KASILOC HILLS SUB., PIAT 66-96) :o 49 TB �r�i. ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAI THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN ..5-1.06.4 N --' THE PROPERTY LINES AID NO VISIBLE ENCROACHMENTS TNF 1NNOeM7TPN N€5080 TS SOO TNl 5154 CP L1rlr INSTITIL106 Sr1CI41ULLT TO 94 NAN EXIST OTHER THAN NOTED. '••f f[wEA NaT COPOTCTS ST W80 WESTING 500XTS u IS.o. rtLINOS NOD/ONT LINOD/ONa L00CNo a S. DATED AT ANCHORAGE,ALASXA THIS 2 ND DAY OF Ls••,. ' 0ASCNNINTS OS*ECM,COIFS F Two TO 4rr[rON lr TNu[m uNO ruT, [ T[Lr e_--f; PcHAY , 2018 N[11: (Ua511 DDIUT[0 rT4: 5)05 R TMT or,Arr(M ON THIS COMM W kW ib K Km TO OETFIerI MOrW I SLNS 1 IRK m AODTTT9YI 1.1011.11e1 l TTf. 510T WO SLIeOMTr •�_ MN WINS 94w MIRK My M YrNppN4liS OA TO fiRSSM 941 M4)/ON I[E. MM t ORM AIMSN 1361(5..n 1110-11 145.0510