Loading...
HomeMy WebLinkAboutKENO HILLS BLK 1 LT 1M �, MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP221412 Work Type: WellSeptic Initial Tax Code Number: 02017111000 Site Legal Address: KENO HILLS BLK 1 LT 1 G:3438 Site Mailing Address: 17201 GOLDEN VIEW DR, Anchorage Owner: ALLEN DALLAS & MINNA Design Engineer: HDL ENGINEERING CONSULTANTS This permit is for the construction of: Q Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: �1»cnt 1° DepaI- talent 2/9/2023 2/9/2024 101880 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. Sumit the Well Decommissioning Log with the Inspection Report (IR). 2. Submit the new soils information collected done prior to construction with the IR. 0,1-,7 3 wo A wc) pc�' W1,1( be o --he, 7.50 paa. -1-o be 1V,-1C')r -f-o -t�e_ QojS. "anG(/ VC, cz 1 713 �_'v 10 C'q ff Z_ (C Z/ 20 Z -� C 1L1-�-6 r-)) 1-0 CJ4--F = co # 3 Received By: l S �� - _F0 Q L Date: Issued By: Date: 2 5 �2 4 cc) L - Civil Engineering Geotechnical Engineering Transportation Engineering Aviation Engineering W/W W Engineering Environmental Services Surveying & Mapping Construction Administration Material Testing I M____iConsultantSLLC ENGINEERING l October 11, 2023 Curtis Townsend, PE Onsite Water & Wastewater Municipality Of Anchorage 4700 Elmore Rd Anchorage, AK 99507 Subject: Allen Wastewater System - Keno Hills Sub Lot 1 B1 Dear Curtis: 49 T ' IMlartc e0; ren II D&ts11 Oct 23 l . No. CE 166793W� iORti�PRO' FESSIO�Q��� Cry Q 3 This letter is provided to summarize onsite observations and email correspondence regarding subject site wastewater system plans. Background The subject residence is a four-bedroom single family residence. Plans for the subject site wastewater system were based on test pit data provided by ANTHC. The test pit showed a sand and gravel layer at 11 feet. HDL was planning to install Type II -A engineered receiving soil down to this sand and gravel layer under a two -foot filter sand mound. A Quanics advanced wastewater treatment system is proposed for treating effluent before it reaches groundwater. The plans requested for the contractor to verify the sand and gravel layer by sieve analysis prior to constructing the wastewater system. Site Observations On Tuesday October 2, 2023 HDL was onsite when the contractor was excavating a test pit to verify the gravel/sand layer called out in the ANTHC test pit log. The contractor performed an excavation to approximately 14 feet roughly at the middle, north end of the proposed soil absorption system. The soil layers were consistent with the ANTHC test hole for the first 6 - 6.5 feet. After 6.5 feet the soils transitioned from Blue Silt to Brown Silty Sand and were consistent to the bottom of the test pit. A soil sample of the Silty Sand was collected for lab analysis from the stock -pile. The lab analysis from Shannon & Wilson showed the receiving soil layer was classified as a Sand Loam. We did not perform a percolation test in the receiving soil due to the depth of excavation and shallower saturated soils observed on site. We estimate the percolation rate of the Sand Loam at 16 — 30 min/inch based on the USCS classification and the Wastewater Application Rate Table in the ADEC 18 AAC 72 Wastewater regulations. The Quanics units with a two -foot thick filter sand are approved by Municipality Of Anchorage for 3335 Arctic Boulevard, Suite 100, Anchorage, Alaska 99503 907.564.2120 1617 S Industrial Way, Suite 3, Palmer, Alaska 99645 907.746.5230 110 Trading Bay, Unit 120, Kenai, Alaska 99611 907.564.2120 Allen Wastewater System - Keno Hills Sub Lot 1 B1 Ocotber 11, 2023 a Cat III application rate based on the receiving soils, see attached letter from Garness Engineering. The Municipality of Anchorage Wastewater regulations Table 6 — has application rates for Advanced Wastewater Treatment Units; a Cat III application rate for our estimated perc rate is 4 gpd/sf. The proposed basal area under the mound system, estimated at 33 ft x 23.5 ft,; is over 700 square feet total. This basal area of the proposed system is sized greater than 1 square foot per gallon of wastewater demand per day (600 gpd for 4 -bedroom home), and could support a more conservative percolation rate than estimated. We propose for the plans to remain as approved by the MOA. The system should be constructed with 11' of Type II -A material imported on Sand Loam receiving soils over a 33 ft x 23.5 ft area. A two -foot thick filter sand mound should be constructed under the proposed chambers. The sand mound should extend approximately two feet past the chamber area prior to a 2:1 slope on the sides. The soil cover over the chambers and filter sand will have a 3:1 slope. If you have any questions about this memo please feel free to contact me. Sincerely, HDL Engineering Consultants, LLC 67�!Irt Mark Fondren. PE Civil Engineer e: mfondren@HDLalaska.com I o: 907.564.2120 1 d: 907.564.2128 Attachments: Garness Engineering Cat III MOA Approval Letter (1 page) Shannon & Wilson Lab Analysis Results (4 pages) Limitations (2 pages) CC: Russell Snyder, ANTHC Chris Bowman, PE, HDL H:Vobs�78-021 ANTHC Term Contract 78 -TC -767654 (ANTHC)i52 - Welland Septic Designs - 2Anchorage HomesO6 CAW/en - MOA Letterment7 r ( a lL4 Q11SHANNON & WILSON, INC. Project Name: ANTHC 2023 Scattered Sites GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS Location: Anchorage, Alaska Particle Size Analysis ASTM D422 Client: ANTHC Liquid Limit, Plastic Limit, Plasticity ASTM D4318 Project Number: S&W: 111538-003 Index iDate: October 9, 2023 KEY DESCRIPTION - Not present or not applicable % Percent. Percent passing is based on total dry mass MITI Millimeters. Sieve sizes shown are based on ASTM Ell standard sizes. 11 Inches. (USS is United States Alternate standard from ASTM E11) NP Not Plastic USDA United States Department of Agriculture Russell Dlgiully vg dby Reviewed by. Hepner, EIT 111.1ao 5430 Fairbanks St., Ste. 3, Anchorage, AK 99518; (907) 561-2120 Page 1 of 1 Sample Information Allen, D. Anchorage, AK 11' Grain Size - % passing Sieve Size - mm (USS) 100 (4") - 75 (311) - 63 (2.5") - 50 (2") - 37.5 (1.5") 100 25 (1") 99 19 (3/4") 97 12.5 (1/2") 93 9.5 (3/8") 90 4.75 (#4) 81 2.36 (#8) 72 2.00 (#10) 70 1.18 (#16) 63 0.600 (#30) 56 0.425(#40) 52 0.300 (#50) 48 0.150 (#100) 42 0.075 (#200) 35.7 Hydrometer (interpolated) 0.02 25 0.002 7 Liquid Limit .17 Plastic Limit 14 Plasticity Index 3 USDA Classification (portion passing #10 (2mm) only) Sand 0.05-2 55 Silt 0.002-0.05 35 Clay <0.002 10 Texture Sandy Loam (SL) Rock Fragment Modifier Gravelly KEY DESCRIPTION - Not present or not applicable % Percent. Percent passing is based on total dry mass MITI Millimeters. Sieve sizes shown are based on ASTM Ell standard sizes. 11 Inches. (USS is United States Alternate standard from ASTM E11) NP Not Plastic USDA United States Department of Agriculture Russell Dlgiully vg dby Reviewed by. Hepner, EIT 111.1ao 5430 Fairbanks St., Ste. 3, Anchorage, AK 99518; (907) 561-2120 Page 1 of 1 0Y w 0 a } 2 0 0 N it 0 0 lY W o coD Z w O W N 0 m m N :r U r w U Z Z_ N (D 2 M 2 w 0- 0 O >w> W N o m to LO o 0 0 V Cl) N 1HOGM A8 2i3NI31N33M3d 0 0 0 Cn tY w I— w J J Z w N U5 Z 0 0 00 ANTHC 2023 Scattered Sites Anchorage, AK GRAIN SIZE CLASSIFICATION October 2023 111538-003 "'SHANNON & WILSON, INC. FIG. 1 Geotechnical and Environmental Consultants U N ca U U � o U o Q M U 0' O J o o 0- J_ J ti .0 J r � 0 O r d) 0 c O U Q O d Q E > QT ''Lnn E c V +' O M U) 3 c m U c is U U) 00 in (D 00 O d c J W R' Loo a) `m co O U r r � W0 O J r, cL) 00 a a Ib , O U C F a E a M • (`°n • GRAIN SIZE CLASSIFICATION October 2023 111538-003 "'SHANNON & WILSON, INC. FIG. 1 Geotechnical and Environmental Consultants 60 CL CH 50 P L S 40------ T I C T 30 Y I N 20---- D E X 10 CL -ML ML MH 0 0 20 40 60 80 100 LIQUID LIMIT Boring Depth, Ft LL PL PI Fines Classification ® Allen - Anchorage - 11 ft 17 14 3 36 Silt (ML) - portion passing 0.425mm only ANTHC 2023 Scattered Sites Anchorage, AK n ATTERBERG LIMITS RESULTS October 2023 111538-003 MIN SHANNON & WILSON, INC. FIG. 2 ® Geotechnical and Environmental Consultants MultiPointTriangle (v1) Clayey ^Jery Fire) ANTHC 2023 Scattered Sites Dallas Allen Anchorage 111538-003 10/9/2023 MUMU A UTY OF AHCHORIAGE Development Services Department - Phone: 907-343-7904 On -Site Water & Wastewater Section --- Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I. D. 02017111000 Property owner(s) Dallas Allen Mailing address 17201 Goldenview Drive, Anchorage, AK 99516 Site address 17201 Goldenview Drive, Anchorage, AK 99516 Day phone 907-317-5154 Legal description (Sub'd., Block & Lot) Keno Hills Subdivision, Block 1, Lot 1 (Plat: 71-150) Legal description (Township, Range & Section) Seward Meridian, T.11N, R.3W, NW 1/4 SEC. 11 Lot Size 101,880 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field 0 Initial 0 Single Family (SF) 0 ADU) Septic Tank 0 Upgrade El(w/wo (D) El Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Chris Bowman, PE (Signature of property owner or authorized agent) Permit/Rush Fees: a2s = ?2-0 Date of Payment: 16 k; Receipt Number: oa`{o`{ Permit No. 65e2_2_ - Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 Division of Environmental Health and Engineering G-002 2 4 DESIGN CRITERIAANCHORAGE, AKSCATTERED SITES- ALLEN &PLATTISSUED FOR CONSTRUCTIONWELL AND SEPTIC SYSTEM GENERAL NOTES PROJECT RESTORATION NOTES GENERAL NOTES REFERENCES DESIGN CRITERIA · · · · · · · · · · · · · · · · · · · · · · · · · · Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221412, Curtis Townsend, 02/09/23 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 Division of Environmental Health and Engineering C-103 4 6 SITE PLAN - ALLENANCHORAGE, AKSCATTERED SITES- ALLEN &PLATTISSUED FOR CONSTRUCTIONSITE PLAN - D. ALLENA11" = 20' · · · SCOPE OF WORK 17201 GOLDENVIEW DRIVE, ANCHORAGE, ALASKA 99516 LOT 1, BLOCK 1, PLAT 71-150, KENO HILLS SUBDIVISION LAT: N 61° 3' 52.82" LONG: W 149° 46' 24.75"; ± 105,850 SF (± 2.4 AC) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221412, Curtis Townsend, 02/09/23 FG: 814.4FG: 813.7FG: 813.9FG: 813.9FG: 813.9FG: 813.9FG: 814.9FG: 815.6FG: 816.1FG: 816.7FG: 817.2FG: 817.7FG: 818.1FG: 818.74500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 Division of Environmental Health and Engineering C-104 5 6 PROFILE - ALLENANCHORAGE, AKSCATTERED SITES- ALLEN &PLATTISSUED FOR CONSTRUCTIONPLAN AND PROFILE - D. ALLENA1HORZ. SCALE 1" = 10' VERT. SCALE = 1' = 10' NOTES MAJOR STRUCTURES ID STATION DESCRIPTION SWING TIE DATA DESCRIPTION DESIGN DISTANCE AB SWING TIE DATA DESCRIPTION DESIGN DISTANCE AB GRADING TABLE ID DESCRIPTION ~VOL (CuYd)ELEV AB SEWER SERVICE ID START END LENGTH SLOPE DESCRIPTION · · · Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221412, Curtis Townsend, 02/09/23 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 Division of Environmental Health and Engineering G-004 4 4 SOILS INFORMATION - ALLENANCHORAGE, AKSCATTERED SITES- ALLEN &PLATTISSUED FOR CONSTRUCTIONSOILS LOGC1NTS MUNI SOILS LOGA1NTS EXISTING SYSTEM DESIGNA3NTS Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221412, Curtis Townsend, 02/09/23 Lm" ENGINEERING L Consultants LLc ANCHORAGE MAT-51.1KENAI 907.564.2120 907.746.5230 907.283.2051 civil • geotechnical • surveying • environmental • material testing www.HDLAlaske.com JOB: I �l ' oV _, Lz J L�.r� TTL rJC— tZ SHEET NO: I OF: J CALCULATED BY: DDA`E. CHKD BY: 4 A,F A ,k DESCRIPTION: Q:••SCALE--.A,- ••: I_,�i Am VN ck- L • . SIMON.: CE -13943 m. rr i, I %\o®to Ar ID�S��oto60 1 1p nrK yS y,J 'So 00) TiN JZM& Mktg r57AF5$ (0+v0 it v N �o(i - c 0-y _?ti = 9 . k N tis �"ST crv- 5 ps -pba, Apr, s !t /Ing > 110,1 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Section (On-site) November 22, 2019 Anchorage Tank II, Inc. 2723 Rampart Drive Anchorage, Alaska 99501 Attention: Tom Varney Ref: Epoxy -Coated Steel Tank Approval Mr. Varney, Phone: 907-343-7904 Fax: 907-343-7997 The Municipality of Anchorage (MOA) On-site Water and Wastewater Section has reviewed the submittal for the steel septic tanks listed below that Anchorage Tank intends to manufacture and market in the MOA, including structural calculations provided in September of 2019. The tanks are approved for use in on-site wastewater disposal systems regulated under AMC 15.65, with the following parameters: 1. The steel tanks shall be used for the application(s) stated below, or as otherwise approved by Anchorage Tank and the Department on a case-by-case basis: • 500 -gallon, 10 -gauge, single compartment for use as an effluent lift station add-on. • 1,000 -gallon, 10 -gauge, single -compartment for use as a settling tank prior to an AdvanTex system with upstream sewage pump. • 1,500 -gallon, 10 -gauge, 2 -compartment for use in up to a 5 -bedroom gravity system, up to a 4 -bedroom pressurized system or up to a 4 -bedroom AdvanTex system. • 2,500 -gallon, 3/16" thick, 2 -compartment for use in 5 -bedroom AdvanTex systems. • 3,000 -gallon, 3/16" thick, 2 -compartment for use in 6 -bedroom AdvanTex systems. 2. The maximum allowable soil cover above top of tank is ten feet, assuming a soil weight of no greater than 130 lbs/cu.ft. 3. The maximum allowable seasonal -high water table level above top of tank is two feet, at up to the ten -foot burial depth. 4. The tanks shall be installed in accordance with the approved trench backfill and bedding detail dated 09/18/2019. 5. All steel surfaces shall be prepared and coated in accordance with approved "MOA Steel Septic Tanks Coating Procedure" and each tank shall be documented with an "MOA Tank Quality Control Checklist'. 6. Proposed and approved coatings are Devoe Bar -Rust 235 and 236 multi-purpose epoxy. Mailing Address: P.O. Box 196650 - Anchorage, Alaska 99519-6650 - http:/Iwww.muni.org/onsite 0 LLL =� u Ju C A mOx O p' 0 0o t NOI1vn3't3 m w I �r s Z , =D - �v w> N O N O n 4 O = r RI ELEVATION m Nk m clnom O CG. 8144 __ O mti ro A a Z� EG' 817.7 >i " o _ Q gf } o Lc ir— 411 z! 0 LLL =� u Ju C A mOx O p' 0 0o t NOI1vn3't3 m w I m o n w> N O N O c I O m 19 frrOD m �' 209gN'NZ Nn ) �+� irO �rOCA N� pZ 1nnNzo_� r ov a r SMOG A } u u } y G(9(9 C V E > a i a N i s g i avv mm-z-mmm-z-z 1 NSI N fww O� 4 Or Z 5� > 4 O } O } +om ~o OOOF > m rFl�i-vJ �o Tz -v. tib O z 9 P z mz A mi A 0 Z m4 A C tin OF pO o Z a z m g p�p > m z z m F mi m o g z U s a oy ♦ 4 c �' z0 r o°z s m � v O A A r m w< CJ o u w z m o t o 40 Ns r c z> c c z a m-S µ m + r I m m < m fmJl f 1 O y K X E O / O f- 2 N fl G W Gy p O O e> N O N O j N I O O frrOD m �' 209gN'NZ Nn ) �+� irO �rOCA N� pZ 1nnNzo_� r ov a IS SMOG 0(9 } u u } y G(9(9 V E y O a N zpu>i>a�� i AA of >.,if _��g mm o£oF avv mm-z-mmm-z-z N fww O� 4 Or Z 5� > 4 O } O } +om ~o OOOF OOSi m rFl�i-vJ �o Tz -v. tib O z = yN»S>i> P z mz A mi A 0 o m4 A m?m=m4 A tin OF pO c a z m g z m F mi m o s U a q oy ♦ 4 c �' z0 r o°z s m � v O A A {a HS w< CJ o �o z o a c c z> c c z 9 m m-S m n� ip i a N9�N m fmJl z u a u m L „9; i i r Hn m z > n i o m 2 I�1 o 0 Sy yu O u >I� x� O m H y y N 2 v I p L o 2 S ti O > O O - '9D A j z 9 9 m 9 m 0 0 (g e> (9 01(9 191810 frrOD m �' 209gN'NZ Nn ) �+� irO �rOCA N� pZ 1nnNzo_� r ov a IS SMOG 0(9 (E) (2) G18181010 19 G(9(9 ! E £ zpu>i>a�� i AA of >.,if _��g mm o£oF avv mm-z-mmm-z-z N H-ZT£ "tnn"s°im;m OF 6i 5� > w A z x Mx ~o OOOF OOSi m rFl�i-vJ �o Tz -v. tib z z = yN»S>i> -1 D mz A mi A 0 o m4 A m?m=m4 A tin OF pO c c z m m F o o s U q oy ♦ 4 o°z s m piw� O O32 ANCHORAGE, AK SCATTERED SITES- ALLEN & PLATT ISSUED FOR CONSTRUCTION m Z .2.ti oO2 2 p N Y OZN�Zj Pf Y w pC z wool frrOD m �' 209gN'NZ Nn ) �+� irO �rOCA N� pZ 1nnNzo_� r ov 0 0(9 (E) 0 0 19 G(9(9 zpu>i>a�� i AA of Of mm o£oF `mm mm-z-mmm-z-z of of OF 6i INi tf ? ?>o$ o� i Oi >�>S>A>A1 OOOF OOSi z>a>a> r. Z r i 9 = yN»S>i> ^-z+�'z" A D mz A mi A mz A m4 A m4 A m?m=m4 A A A o y o 2 ny T iZ��'>'�o _.p V1n o v mq� um-po a T: >N oy yArm"CIOmy� >; ANCHORAGE, AK SCATTERED SITES- ALLEN & PLATT ISSUED FOR CONSTRUCTION m Z .2.ti oO2 2 p N Y OZN�Zj Pf Y w pC z wool INSTALL 6" OF BENTONITE CHIPS AROUND ALL TANK OPENINGS LOCATED BELOW GROUNDWATER TABLE (TYP) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221412, Curtis Townsend, 02/09/23 SEASONAL HIGH GROUND WATER TABLEIMPERMEABLE LAYER 6'-0" MIN4'-0" MINSHEET OF 4500 Diplomacy Drive Anchorage, Alaska 99508 (907) 729-3600 D A B C 1 2 3 4 Division of Environmental Health and Engineering BAR IS ONE INCH ON ORIGINAL DRAWING, IF NOT ADJUST SCALES ACCORDINGLY USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTDFL2.dwg LAYOUT: SSSD-640 MOUND SYSTEM (AT-GRADE) PRINTED: 7/20/2022 3:12:49 PM 0 1"THE REGISTERED ENGINEER FOR THE PROJECT ISRESPONSIBLE FOR THE PROPER APPLICATION ANDINTEGRATION OF THESE DETAILS AND ANY MODIFICATIONSSHOWN. THE ALASKA NATIVE TRIBAL HEALTH CONSORTIUM(ANTHC) OR ITS AGENTS OR EMPLOYEES SHALL NOT BE HELDRESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF SCANNED COPIES OF THIS PLAN SHEET. THIS DRAWING HASBEEN PREPARED BY ANTHC AS AN INSTRUMENT OF SERVICEAND SHALL REMAIN THE PROPERTY OF ANTHC. ANTHC SHALLRETAIN ALL COMMON LAW, STATUTORY AND OTHERRESERVED RIGHTS, INCLUDING COPYRIGHT THERETO.STANDARD DETAIL VERSION SSSD-640 1 1 MOUND SYSTEM (AT-GRADE)1.0 PVC SCH 40 PRESSURE LATERAL, EXTEND TO END OF ROW INSIDE INFILTRATOR CHAMBER AND CAP AT END (TYP) NOTES: 1. COVER INFILTRATORS WITH PROPEX GEOTEX 801 OR EQUAL. PROVIDE 1'-0" MINIMUM OVERLAP AT ALL JOINTS. EXTEND 1'-0" MINIMUM BEYOND ALL SIDES OF INFILTRATORS. 2. EXTEND RIGID 2" INSULATION LAYER 4'-0" FROM BED. 3. DO NOT COMPACT DRAINFIELD BOTTOM. KEEP EQUIPMENT OUT OF THIS AREA. PLACE GRAVEL FROM SIDES OF EXCAVATION AND FINAL GRADE BY HAND. 4. CONFIGURATION AND NUMBER OF INFILTRATIONS BY WIDTH AND LENGTH IS BASED ON SOIL TYPE # OF BEDROOMS, PERCOLATION RATES, AND HOUSEHOLD WASTEWATER FLOW RATES. SEE CIVIL DESIGN SHEET. 5. WIDTH AND LENGTH VARY WITH SITE, SEE CIVIL DESIGN SHEET. 6. ADD INFILTRATOR PIPE STANDS TO SUPPORT THE LATERALS. GEOTEXTILE OVER INFILTRATORS UNDISTURBED EARTH INSPECTION PIPE WITH JIM CAPS INSTALL VERTICALLY STRAIGHT, TYP 4" RIGID INSULATION FINISH GRADE, LANDSCAPED, SEEDED AND FERTILIZED CAP WITH 12" OF TOPSOIL PLAN SECTION 4'-0" 5'-0"INSPECTION PIPE, TYP OF 4 PLACED AT EACH CORNER OF DRAINFIELD 4'-0" QUICK 4 INFILTRATOR CHAMBER 12" x 34" x 52" EACH LENGTH (48" EFFECTIVE LENGTH) DRAINFIELD BOTTOM INFILTRATOR END CAP (TYP) EXISTING GROUND 2'-0" DISTURBED EARTH FILL MOUND WITH CLEAN BACKFILL 1 SEE SITE PLAN2' TO 4'REMOVE ORGANIC MATERIAL TOP OF MOUND MOUND SYSTEM AT-GRADE ABSORBTIONA1 1/2" = 1'-0" 1 3 3 1 2' OF COARSE SAND FILTER LAYER, IF NEEDED OR WHEN PERCOLATION RATE IS FASTER THAN 1 MIN/IN6"1'-0"2'-0" 2'-0" 4" FERNCO CAP WITH SS CLAMP 4" REFLECTIVE TAPE 4" SCH 80 PVC PIPE SET INTO TOP INFILTRATOR W/ SET SCREWS, INSTALL VERTICALLY STRAIGHT 1/2"Ø HOLES 2 ROWS, 4 HOLES EACH (FIELD DRILL)2'-0" (MIN)4'-0" (MAX)4" GLUED COUPLING 10"INSPECTION PIPEA41 1/2" = 1'-0" 2' BED OF 3" MINUS CLEAN COARSE GRADE SEWER ROCK UNDER INFILTRATORS. OPTIONAL GRAVEL LAYER: INSTALL ONLY IF A LOCAL SOURCE OF GRADED SEWER ROCK IS COMMERCIALLY AVAILABLE NEARBY. LATERAL ORIFICE FLUSH PORTS ON EACH LEG 1 1/2" PVC SCH40 MALE ADAPTOR, MIPT x SOCKET WITH 1 1/2" CAP, FIPT HANG 1 1/2" PVC SCH 40 PRESSURE PIPE UNDER INFILTRATOR CHAMBER HOLES POINTED DOWN OR USE PIPE SUPPORTS1/4" ORIFICE 2'-0" OC (TYP) INSTALL LEVEL HEADER: OUTER INFILTRATOR ROWS ARE 1 1/2" PVC SCH 40 90° BENDS, INNER INFILTRATORS ARE 1 1/2" PVC SCH 40 TEES 1 1/2" PVC SCH40 90° LONG SWEEP ELBOW DRILL 1/4" HOLE, POINTING UP AT THE END OF EACH PRESSURE LATERAL TO ALLOW SYSTEM TO DRAINDOWN LATERAL ORIFICE FLUSH PORTSC33/4" = 1'-0" 1 1/2" CAP, FIPT 1 1/2" PVC SCH40 MALE ADAPTOR, MIPT x SOCKET 1 1/2" PVC SCH40 90° LONG SWEEP ELBOW FLUSH PORTS DRILL 1/4" HOLE, POINTING UP AT THE END OF EACH PRESSURE LATERAL TO ALLOW SYSTEM TO DRAINDOWN DB-01, SEE C-104 AND SSSD-600 MIN MOA FILTER SAND EXTEND CLEANOUT TO FG EXTEND CLEANOUT TO FG CLEANOUT4" ABS 4" JIM 4" ABS CLEANOUT 4" CLEANOUTS 4" ABS CLEANOUT 4" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221412, Curtis Townsend, 02/09/23 O�: By: (signature) Date: ((print name) STATE OF ALASKA T111RD JUDICIAL DISTRICT The foregoing instrument w acknowl dged before me s day of 202fthis , by ..aitlr NOTARY PUBLIC FOR ALAS A My Commission expires: MUNICIPALITY: By: (signature) -C v rint name) (rev. 05/18/2018) Date: 2, Title: C (VI L Page 3 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Health Division REMARKS: 211 Ej�[* F SEAL ed by: Ins ections Perfo 0944 Ad' 14— Date. 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT !-p NamerRR[q-T7- certify that this inspection was performed according to ail NCES A TANK ,�, �IEL WELL Addressj. 14m� /V1 e /-r, Phone(s) Permit No.. No. of Bedrooms qDS-71 4 LEGAL 8DESCRIPTION WELL LOT LINE /00 551 ism onC y0 FOUNDATION .50" Township, Range. section T/ AS -BUILT DIAGRAM driveway, water bodies, (Show location of well, etc.) septic system, property lines, foundation, i j I i TANKS' EJ SEPTIC /X HOLDING Nit t Manufacturer Capacity in gallons Material No. of corKpartments TYPE OF SYSTEM thwlv OTRENCH EBEDEW. DRAIN OTHER th to pipe bottom from ongi rade FT Total depth from original grade FT Fill added abov inal grade FT Gravel depth beneath FT Gravel length &,zrVel width FT Total absorption area SQ FT ce between tines FT Number 0 es Soil rating SO FT Pipe material Installer Date Installed Xf I WELLS PRIVATE El OTHER I v) — Classification (A,B,C) at FTT T to Cased to FT REMARKS: 211 Ej�[* F SEAL ed by: Ins ections Perfo 0944 Ad' 14— Date. 72-013 (3165) !-p certify that this inspection was performed according to ail A Municipal and State guidelines in effect on this date: 4 Health Department Approval: Date: A4V&_. 72-013 (3165) � � MUNICIPALITY OF ANCHORAGE Departm�nt o{ Health & Human S�rYi�es ` S25 1. St, reeptg Anchor age v Alaka 99501 343472� O N � G I T E H C) L, D I N G T A N K P E R M I T ���y Permit NuNber: 890271 Up��0 grad� ��/���� /��� Date I�su�d: 12/08/89 Engineer Designed Owner Na0�: GARY GERLING Owner Address: 17201 GOLDENVIEW (NNCAv HK 99516 Day Phone: 349�9604 Parcel Id: 020-171 ..... 11 Lot Legal: Subdivision: KENO HILLS Lot 1 Block: 1 Section: 11 Township: 11N Range: 31A Lot Size 1011980 (sqAt" or acres) Max This 4 "fatal Capacity: 4 HOLDING TANK: Mininum Tank Size: 2x500 gallons. IN high Nater, alarm 0ugt bee installed on the tank and Connected to the resideRce. Depth to top of holding Lank < 4.0 feet rCOquires insulation over, tank" Al MINIMUM OF 75/ MUST BE MAINTAINED BETWEEN THE HOLDING 'TANK AND ANY WELL" A COPy OF A PUMPIME3 CONTRACT MUST BE PROVIDED WITH THE AW -BUILT DRAWING" AUDIO AND VISUAL ALARMS MUST BE INSTALLED INSIDE THE DWELLING, THE EXISTING MQGT 8E PROPERLY ABANDONED° I CERTIFY THAT: 1" I ani familiar xvith the for on~site sewers and wells as set forth by the Municipality of Anchorage (M[A) and the State of Alaska. 2" I will install the syltitem in accordance with all MIN codevi and regulations, and in compliance with the design criteria of this permit. 3" I will adhere to all MOA and State of Alaska requirements for the set b�ck distances from any existing we1l, wastewater disposal syste6o or public ��werage syvitem �::)n this or, any adjacent or nearby lot, 4" I understand that this permit is yalid For a maximum Of 4 bedrooms" I undePii.--itand that the capacity of the total system is 4 bedrooms and any enlargement will require an additional permit" Signead (Ow| Issued A, DATF; �����... ... ... ........ . -6 46� +.e Municipality of Anchorage T DEPARTMENT OF HEALTH & HUMAN 825 "L" Street, Anchorage, Alaska 9951 SOILS LOG -- PERCOLATION PERFORMED FOR: NAIUG`/ tSlECLI 11 < LEGAL DESCRIPTION: L I 91 KEF Township, Ran SLOPE •l< . d •/ • EJ >r+S•• f • 8w J. orw 114 �: qE C, 243 •' �� � •, ki �vjr y•O! a iii t. Pf• l 1.`II g 31 189 �cPE� ED: S ction. IGC `e, SITE PLAN WAS GROUND WATER ENCOUNTERED? L� S 1 IF YES, AT WHAT �e 3 0 DEPTH? P E Depth to Water After p 8 Monitoring? 8 Date:_ Gross DEPTH OL Net (FEET) Time Water Drop sPLvP 2 IY 9 rac%al "Acl 3 51,3ti4. "o,, Sc..p 4. V 4 5 SM -ML 6 5.1+, Sonlc 5u�d 5,M11 S -Toles 7 th+ce of C'Av 8- 10- 101112 11- 12 . 1314151617 81920 18- 19- 20 COMMENTS Township, Ran SLOPE •l< . d •/ • EJ >r+S•• f • 8w J. orw 114 �: qE C, 243 •' �� � •, ki �vjr y•O! a iii t. Pf• l 1.`II g 31 189 �cPE� ED: S ction. IGC `e, SITE PLAN WAS GROUND WATER ENCOUNTERED? L� S 1 IF YES, AT WHAT �e 3 0 DEPTH? P E Depth to Water After p 8 Monitoring? 8 Date:_ Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes inch) PERC HOLE DIAMETER _ TEST RUN BETWEEN FT AND FT ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72.008 (Rev. 4f65) '55e1s4 u � � InG ` x 6° 6Y7e Peel 1 � a qecG&m AoUdr dig% Soi is Trer�'Li �- East 283' 61 I <1 V SEWER SYSTEM LOCATION PLAN -•+. - LOT BLOCK SUBDIVISION SECTION/TOWNSHIP/RANGE wt� /uwe �'y P SCALE- // /. NOTE.. THE ACCURACY OF LpQpTIQN OP_EXISTING a7 �� _ PROPERTY CORNERS, WECLS� ANO:SE`PTIC ro�.ar DRAWN BYE �7 SYSTEMS INDICATED IS;fjOT EXACT f NORTH ,[�./C DIMENSIONS INDICATFOe HAVE BEEN DETERMINED BY USE DF `LOTH TAPE AND NOT BY SURVEYING TECHNIQUES. � PREPARED FOR, o C • 1 A /a5,la GISA mea! U. yef i 35 I ProPosP� -\e 7H�. 5, e t Z�vtF:!__ r 7m-�. Trer�i - 0 0 0 iz 1� /O - .I✓kLSTrr..3Z� S`CST�M A-3-PUtt✓T SEWER SYSTEM LOCATION PLAN LOT . -BLOCK SUBDIVISION A�SECTION/TOWNSHIP/RANGE - lu AIW!�*SES. // T% Z• SCALES /I/� SO' NOTE.. THE ACCURACY OF LOCATION OF EXISTING + - PROPERTY CORNERS, WELLS, AND .SEPTIC s�•��• DRAWN BY- SYSTEMS INDICATED IS NOT EXACT. NORTH B✓C DIMENSIONS INDICATED HAVE BEEN r. ....... : _ , DETERMINED BY USE OF CLOTH TAPE AND Corwin ' - 7•..;=�• - "�>. NOT BY SURVEYING TECHNIQUES. pry z Q t PREPARED FOR- A la54-a OR+A/a5,ea usfl Gec,�cu. ,ee: lies/i, ,oio ,cC Consul tnq Enyecs DATES y�BCJ SHEET / OF MUNICIPALITY OF ANCHORAGE ` DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAM � - PHONE EJ NEW PGRADE MAILING ADDRESS LEGAL DE SC IP) 14 ✓SC J LOCATIO ,, r r NO. OF BEDROOMS �? DISTANCE TO: yU���,� g , �O�% Ir:; j(_K-.�C Absorption area Dwelling �� .r► PEFW NO. "11616 Y EQ W Manufacture �� Meter ial-7r� No, ofc partments H Liq. c@pa it i gallons C IF HOMEMADE: Inside length Width Liquid depth O Y _Jaz DISTANCE TO: Well Dwelling PERMIT NO. = Z H Manufacturer Material Liquid capacity in gallons O W.2 .DISTANCE TO: Well �` Foundati f / Nearest lot i �� PER X10/ / (/ ®/ 4 W u V F z w No. of lines � Length o a lire 9 (p Tota le ofJines Tr th � inches Distance b e as /Cl QccTop p of tile to finish grade Material beneath tile Q inches Total effe a or tgn area I LJ LU a Length Width Depth PERMIT NO. i F LU FL Type of crib Crib diameter Crib depth Total effective absorption area W H DISTANCE TO: Well Building foundation Nearest lot line J J Class Depth Driller Distance to lot line PERMIT NO. W DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS SOIL TEST RATING �l INSTALLER / V REMARKS APPROVED 72-013 (Rev. 3/78) L -- DEPARTMENT HEALTH AND ENV I RONMENTAL%4Rt3TECTI ON 1116n STREET, ANCHORAGE, RK. 9950:1 264-4720 PC PERMIT NO. 811016 APPLICANT DON C. BRADFORD JR. PO BOX 10-628.3 4 5 1 X15 ie=-- -2 LOCATION GOLDEN VIEW DR. 9t erhom:S4 1 LEGAL LOT IBLK I KENO HILLS SUB LOT SIZE 87120 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS 4 SOIL RATING e.Sll FT,,'BR)= 150 JIL THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: E -a F-- F=`r FA =-= S-9 A � t-4 0 -r- V-# — 1CS CEO 1:3 F? F1'v� [—= L_ E=s ElF::lm­F � l == of; THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT 15 THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF 'THE EXCAVATION (IN FEET). PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS 6EPAOTM6417 DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND.TFIE NUMBER OF RESIDENCES THAT 'THE WELL WILL SERVE. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL. BE SUBJECT 'TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON—SITE SEWAGE'DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE 'TYPE OF PUBLIC WELL, MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F=okEF,"Ml-r EEXF-`IFREE _�� C=g IEE 0F_=ME3E:F-` -1.!F4 -*E:� flL I CERTIFY THAI" 1: 1 AM FAMILIAR 14ITH THE REQUIREMENTS FOR ON-SITE SEWEk:5,FjND WELLS, AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: 1 WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES, 3: 1 UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE 11 RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. SIGNED: ------- I'- __ '�Pl P P L I CA N T :� �- il c. B R A D F 0 R 1) J P., V4. 0 i s j ( SOILS LOG �l X +'MUNICIPALITY OF ANCHORAGE ,�/ / • DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION u PERCOLATION 825 L. Street, Anchorage, Alaska 99501 264-4720 TEST SOILS LOG - PERCOLATION TEST PERFORMED FOR:`�6 (Z -� DATE PERFORMED: LEGAL DESCRIPTION: A- <1 x I -;6L 1 2 3 4 5 6 7 8• 9- 10- 11- 12 13 14 15 16 17 18 19- 20 COMMENTS SLOPE SITF PI nni PERCOLATION RATE T, 3' (minutes/inch) TEST RUN BETWEEN 6 C% FT AND 12, ` FT PERFORMED BY: VcQ�O-(' I CERTIFIED BY: 72-008 (6/79) DATE: %— Z -F_ f�� - - DATE RECEIVED . APPOINTMENTS 5. LEGAL DESCRIPTION ^� e,97- /.� el f INSPECTION STREET LOCATION % E 6. TYPE OF RESIDENCE : TIME _ TIME DATE � SINGLE FAMILY -DATE - DATE �. INSPECTOR 7. WATER SUPPLY INSPECTOR - _ INSPECTOR ATTACH WELL LOG. A well log is required for all wells drilled COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) J2o 7� %Z MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & Z YEAR ON-SITE SYSTEM WAS INSTALLED. DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECT14WA NMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 • 1981 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 RE CUM, REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page I. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE Al MAILING A SS PROPERTY RESIDENT (If different from above) _� PHONE 2. BUYER PHONE MAILING ADDRESS 3. LENDING INSTITUTION PHONE /, iL MAILING ADDRESS 4. REALTOR/AGENT _ - PHONE - MAILING ADDRESS - - DATE RECEIVED . APPOINTMENTS 5. LEGAL DESCRIPTION ^� e,97- /.� el f / �P/90 STREET LOCATION % 6. TYPE OF RESIDENCE : NUMBER-OF,BEDROOMS ❑ One ❑ Four ❑ Other � SINGLE FAMILY ❑ Two ❑ Five ❑ MULTIPLE FAMILY l� Three ❑ Six 7. WATER SUPPLY [� INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) J2o 7� %Z 8. SEWAGE DISPOSAL SYSTEM T21 INDIVIDUAL/ON-SITE** Z YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. -010 (Rev. 6/79) -,. _ ° `"i,�' r'- e. '-C. naa' ft€-": -'C�.- 1 r I w THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER- ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑JNDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED INSTALLER ❑Septic Tank or ❑Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4.'DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ®d PROVED FOR _,� BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE BY 72-010 (Rev. 6/79) � DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE " - 0 One E:1- Four El Other - - LSI_ to INSPECTOR INSPECTOR INSPECTOR MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE' DEPT. HEALTH , DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI�l� -rIVVIRONMENTAL-. PROTECTION N 825 L Street - Anchorage, Alaska 99501 • OCT 8 1980 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 RRF�'PA£FF�� OU FF REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWEPFFG"�40 DIRECTIONS: Complete all parts on page 1.. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE f 9+7L ' YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY MAILING A DRESS Aa 3 /o -4 z. K C4 t.4.$ *0 9 g.f// PROPERTY RESIDENT (If different from above) PHONE - 5.9•+�c 276 �65GL 2. BUYER PHONE .MAILING ADDRESS 3. LENDING INSTITUTION PHONE MAILING ADDRESS 4. REALTOR/AGENT PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION GoT I /47LvCk keWps STREET LOCATION' . 2 r �r;e"AY '^* ev: 6. TYPE OF RESIDENCE, NUMBER OF,BEDROOMS 0 One E:1- Four El Other 19 SINGLE FAMILY ❑ Two ❑ Five ❑ MULTIPLE FAMILY iig. Three ❑ Six 7. WATER SUPPLY "fes- INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to th t date, give well. , ❑ PUBLIC UTILITY depth (attach log if available.) oW44e /Cjr'f /209 r 8. SEWAGE DISPOSAL SYSTEM - INDIVIDUAL/ON-SITE** f 9+7L ' YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY ST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED NOTE: THE INSPECTION FEE MU E q n 72-010.(Re9) _.Q 4U �8-' 72-010 (.Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ TWO ❑ FOUR ❑ SIX ❑ OTHER 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑ INDIVIDUAL/ON -SITE ID PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED INSTALLER ❑Septic Tank or ❑ Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ❑ APPROVED FOR BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) &;--DISAPPROVED DATE Fo 'tea BY •i�� 72-010 (.Rev. 6/79) Municipality o 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111. GEORGE M. SULLIVAN, MAYOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION October 13, 1980 Don C. Bradford, Jr. Post Office Box 10-628 Anchorage, Alaska 99511 Subject: Lot 1 Block 1 Keno Hills Subdivision Approval for your individual sewer and water facilities cannot be granted until the following items have been completed: (1) The water analysis report be delivered to this department from Chem Lab, 5633 B Street, for our review. (2) Locate and expose the standpipe to the leaching area for our inspection. This needs to be extended twelve(12) inches above ground level. This is to insure the minimum distance requirements are met between your well and sewer system. (3) Locate and expose the standpipe to the septic tank twelve(12) inches above ground level. Also, fill in the depression around the cleanout. (4) A soils test will be required to determine if ground water is present. (5) If there is not ground water entering your system and the leaching area is 100 feet away from any stream and 100 feet from any well, then an adequacy test will be necessary. (6) Locate the well for our inspection to determine proper construction. J14 - Don C. Bradford, Jr. October 13, 1980 Page Two (7) The septic tank pumped with a receipt submitted to this office. The total number of gallons pumped need to be on the receipt to verify the size of the tank. This will need to be verified by a registered engineer prior to submittal. If there are any further questions, please call this department at 264-4720. Please notify this department for a reinspection when the noted descrepancies have been corrected. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw �•''r Municipality of Anchorage On -Site Water and Wastewater Program , (907)343-7904 Parcel I.D. 020-171-11 Certificate of On -Site Systems Approval �— JUN 2 6 2015 Expiration Date: /U' 6, Y 1. GENERAL INFORMATION Complete legal description KENO HILLS; BLOCK 1, LOT 1 Location (site address) 17201 GOLDEN VIEW DRIVE *ANCHORAGE, AK 99516 Current Property owner(s) MARK SCHAVE Mailing address Real Estate Agent Day phone 727-0489 17201 GOLDEN VIEW DRIVE `ANCHORAGE, AK 99516 GORDON SLOANE 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 ❑ 4. TYPE OF WATER SUPPLY: Individual Well ❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ WaiverNariance request for: N/A Received Day phone 244-3381 TYPE OF WASTEWATER DISPOSAL: Individual ❑ Holding Tank Community ❑ Public Sewer ❑ COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $J5ai% . Date of Payment Wag 115 Receipt Number a(.4024 COSA # 66C1573110 Date: Waiver Fee $ Date of Payment Receipt Number Waiver # NIA 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate f .pyT of bedrooms and type of structure indicated herein. I further verify that based on the information o ine {...' he Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Garness Engineering Group, Ltd. (GEG) Phone (907) 337-6179 Address 3701 E. Tudor Road, Suite 101, Anchorage AK, 99507-1259 Engineer's Printed Name Jeffrey A. Gayness In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the systems on the dates of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend on a variety of variables including, but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of .construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the systems; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail. The content of this report is for the sole benefit of the pemon/party who retained GEG. Reliance upon the information provided in this report by any other person or party, including but not limited to subsequent property purchasers, is not authorized. In short, GEG disavows any legal duty to anyone other than the pemon/party who paid for this report. Date 1. fs OF 6. DSD SIGNATURE ` J= ON-SITE System #1 Approved for 4bedrooms "� WATER AND System #2 Approved for bedrooms m WASTEWATER 4 PROGRAM Disapproved < Conditional approval for bedrooms, with the following stipulations �l����iV 7- SERv>>�'�l� as Original Certificate Date: _ - fit% "46� The Munidipality eYAnchorage Development Services Division (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet &1-12.dac If more than 7 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: KENO HILLS; BLOCK 1, LOT 1 ParcellD: 020-171-11 *PER GEG INSPECTION **TO 40' OR BEDROCK—ASSUMED BASED UPON SURROUNDING WELL LOGS A. WELL DATA. Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed —1971 Sanitary seal (Y/N) YES Total depth *112+ ft. Cased to ** ft. FROM WELL LOG Date of test NO WELL LOG Static water level ft. Well production g,p,m. WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate ND mg./L. #jN Well Log (Y/N) NO Wires properly protected (Y/N) YES Casing height (above ground) 12+ in. AT INSPECTION 5/26/15 25.4 ft. 0.4+ g.p.m. Collected by: GEG. Ltd. Arsenic: ug./L. Date of sample: 5/26/1 B. SEPTIC/HOLDING TANK DATA STEEL HOLDING TANK IS APPROACHING THE END OF ITS USEFUL LIFE (26 YEARS OLD) I Tank Type/Material HOLDING TANK STEEL Date installed 12/9/89 Tank size 4000 gal. Number of Compartments 1 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) ' Date of pumping 5/28/15 Pumper AROUND THE CLOCK PUMPING C. ABSORPTION FIELD DATA Date installed Soil rating (g.p.d./ft'or ft2/bdrm) _ System type Length Width Total depth ft. Elf. absorption area_ ft2 Monitoring Date of adequacy test Results Fluid depth in absorption field before tet! in. Elapsed Time: irt" Final fluid depth _ Y_ra venation treatment (past 12 mo.) (Y/N & type) Gravel below pi ft. over field For bedrooms Water added _gal. New depth _in. in. Absorption rate >= g,p.d. If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN "Pump on" level at in. "Pump off" level tom; . High water alarm level at in. Cycles tested Meets alar & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot N/A On adjacent lots 100'+ Absorption field on lot N/A On adjacent lots 100'+ Public sewer main Public sewer manhole/cleanout 100'+ Sewer /septic service line 25'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field N/A Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 75'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line Building foundation Water Water service line Surface water g/vehicIe storage Curtain drain ells on adjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that I,have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA gujdshnes in effect on this date. Engineer's PrIntel Name JEFFREY A. GARNESS Date QUIT (Rev. 11/06) Municipality of Anchorage ,x", Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # 151316 During a recent COSA on-site inspection and test of the potable water supply well on Block 1, Lot 1 of Keno Hills subdivision, the well's productivity was determined to be 0.4 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is 0.42 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. J LO s 7 N 0 J 0 MO N 00w N 0 J 00'09C M,00,£O.00N 00'09C NL,OO.CO.00N O LO W �Urnot m O .0 m aao�ou 'o yoy fl, o .o o Q , Y N rn� smv�c�'� aa2 = L a m m a co F' �F t c o c 0 F -a mLa m } c U mO Y 3:s 0 2 N x Q Q N _ p W 9 z 10`wom o Oc < Z Ica- Qc�'o=ma `o W'm 0 0- E z a n Y v W W t9m �a w0o3umi Q m O r c o o N m m E� n- , m m 0 .5j 0O dO O m L2 0 0o002E Um msmmg0= � v m(p m 0N aQm mQ m wNC mZ oa o v 0 w Y av m m a m d N o � E W ca z Hp W -Ii. s a0 00 — Y I /0 • m x wz V0=- Lu z Hp �w p — o02 ww = x wz V0=- Lu ii Wo= U. s - w Z F OOZ wn� — W � S LL, Cr 4oa. u. W F- 0- 14 w %J 01 31 4 Ci 4J: mi $4! cu i 10 cl, -0 w C\J: r.+! w! Z I-- Vd:: .411 1511 c, o o o o o ci ci 6 6 1- 14 64 1.- L4 I. H H E4 k. i" cyC\I! � A —�z CA Ik 0 0 0 0 0 0 00 cc 9 0 9 9 cc 99 24 a), ul w lk lu k.. w W fir_ w 52; j OC y EJ do O.W. i C4: EE Al PI4 S4 P S Pf ai Q a to to c3i Cr: ui i i tn 0 0: . . . . 1 n at 0 0 0 4:4 U) 0 14 64 K 1,4 h EM P z +J: cx)i on i Ni oi 01 411 N pi cdf C141 U'Ni Cal VU OD: Qi cyl oi .4 00 ml cd 94 —1.: Oki: LQ o 0 0 a 0 0 0 Id ca cc Id 'k Id r. IN Ik rh 06 fk f1d sk 1% f4 Ik Aw 04 �g &8T.9 I ;�t 70 Aft w OF is Wl 'A #V 4-1 is i WATER WELL RECORD STATE OF ALASKA i[ DEPARTMENT OF NATURAL HIESOUHES a Division of Geologicoi a Geophysicol Surveys U I I Dr Ullnp Patel, No. 870041 LOCATION OF WELL (?baa [..pill. .'In., lay to yr Jc.l A.D.L. No. �IoJ BproJpA 9uhalri{lull -. Lal ala<k IE. :/. p Sr[flen Na. Teva{nip N pollee E� MNldlen Ant$ JEFFERS:: 2 —.f. o1.m. s❑ wp _ •IIt DISTANCE AND DIRECTION FROM ROAD INTERSECTIONS !, OWNER OF WELL: RAY JEFFERS Address: Slnel Additive and Area at Well Lacallen , �g. ..ELL L06. .. Fe[I Bala. Surle< O. WELL DEPTH'. Illnall S. GATE OF CaMPLETION %%D It. 9 — 1 O - 97 F M .1. 11. Ty Oe Tap &ol(gm ILtill - S. "❑Cable fast'}MAct..Y ❑Driven 0Dug 01.11.. 00.114 ❑Other: ( rAy hLard rnoicA.,., Id TASE: EyyG—tic O Public Supply ❑ Industry ❑ D[roml.n ❑ Fathered Ll cam..rl.a1 O Tell Well 0 a1Mr: streaks ' R CA $191; l.) Thb.dea slued dldel. ' 6 in. in 93 IL Depth wi.iw dl m In. 1 I1. Deal. Sued., _ Sal 1 e. lD 1 . I _ 4 DI'' "1'1D1 9. FINISH OF WELL: -g Trp. 4.pen hole Dmm.l.r:gpm 1 ' . -- 199�--1 sml/M.en SI[e: Lenin. _ ,r 391 all...n 11. and fl. Backfilling Gravel baby26Q" 1 10. STATIC WATER LEVEL: _ N. — z jR250r — "f I - �aea.. or )uBsm. I..a..Iran Eau 1pm.nf ...d: II. PUMPING LEVEL below land .arra.. and YIELD damalna�g.p m. _fl, after _hrs. Wt2 __ o.a. m. -� 12.®PDUTIN6 Well G.O.led: Vs.Na Material; 0...I C....1 0Other: " 1 IS. PUMP: 111 aV011aa1.1 HP L.nvlh of Orap P p. _'L mpaa Iy _p p 0 Sabin. 0 bl O O.nlrlflcal ED 01h { u.REMaRNs: LINED WITH 4�T I.D. 1 ' PVC WELL PIPE 2$1011500"Ase/e!;4 Id. WATER WELL CONTRACTORS CERTWICAT)ON: —� 13. Weser bmpara tu.a � � F � C Tn([ well wva Lrill.a anus 11 fa.lea telae Ind tnlc r.A." M Nue 10 119. a." .f my knowledge V'V ballot; AK N"ZT.LLS2'MN-' roTT T TNG '& ENT .} — Repielared 5..m... Nam. - 'CbdrNEl2l d de Mumae Addr... ; 1221Avion s . AnchoraLte. AK 99.516 slan.a: oma: /0-aZ. eF7 Aulherlxa Peer eclollva I �F.:.02-WWR4II/SI) Copy Olalri.ulion: WHITE-Slale DOGS, PINN-orlll.r, CANARY-Gosame. Alaska state law requires that a copy of this well log he sent to the Department of Natural Resources within 4.5 days: faxes arc acceptable. (AK stauues 38.05.020, 38.05.035.41.08.02b, 46A -S.020 and AK regulations I 1 AAC 93.1}0). DNR! Division of Mining, Land and "ater, 550 w 7th Avenue, Suite 1020 Anchorage. AK 99501- 3562 Phone(907)269-8439 and UN, (907)249-8947 Within the City of Anchorage, it is required that a copy of the wel I log be sent to the appropriate city office within Gil days and that another copy of the well log be sent to the welliproperty, owner within 30 days. Pcrmit Number. class C Date of Issue:_ Parcel Identification Number: Is well located at approved permit location? ( X) Yes or ( ) No STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING, LAND & WATER WATER WELL LOG Drilling Started: 10, 18,2005Contrieted.10, 21/2005 City/Borough: Subdivision: BLOCK LOT Propertv Owner Natnc R Address: Larry Mebaln 8901 Trail St. Anchorage, Ak. 99507 nchorage Pennington Park 2 g Meridian Township Range Section %a of 'ln of %a Of i/o- BOREHOLE DATA(frorn top Of casingepth Drilling method (X) Air rotary, ( ) Cable tool, Other Material: Type, Color &. wemess ? From To Well use: ( )Public supply, (X) Domestic, Other stickup 0 2 Depth Of hole: 268 tt Casing stickup: 2 rt Casing type: steel _ Thickness: _-.250_ Inches clay & rock 2 18 Casing diameter: __ 6—_. inches Casiagtlepth:__ 78 ft Liter type: - Diameter: - inches Depth: - ft coarse rock 18 28 Static water (fir°'" top of easing): 115 tion 10 21 2005 Pumping level &yield ......... feet atter hours atb'Pm Recovery rate: 2 gpm, Metbod of testing: airlift silty clay &rock 28 36 Development method: airlift Duration: 1 hour wet silty clay & rock 36 38 Well intake opening "type: ( } Open end, (X) Open hole, Other__ Screened: Start: - h', Stopped dry silty clay & rock 38 42 Screen tyke:...___= Slournosh size: - Perforated: Start: - ft, Stopped: - ti Start: - ft, Stopped: _ - tt silt & rock 42 75 Note: ... ..................... -- ....... ......_.....:..................... ............. bedrock 75 268 grout type: _bentonite__ vammc - Depth: from -_ground surface PUMP intake depth: it Pump size: lip, Brand name: Was well disinfected upon completion? (X) Yes, € ) No Method of disinfection:...Ghlorine......... ---- ........ ............. ............. Driller commcntsi disclaimers: . ......... ........................ .. water entering thru fractures at depths of 80',185', and 195' for a total of 2 Bpm ......... ...... ....................... ..................................................................................................... Well driller name:.Curt:Hefty ......................................................... Company name:... Hefty. prillin9,..Inc................ ....... ............ . Mailing address: ... 3540_Akula, Dr .......................................... ....... City: Anchorage sate: AK zip 99516 Phone number : ( 907 } 345 _ 0593 faX 345-4700 Drillers signature: Alaska state law requires that a copy of this well log he sent to the Department of Natural Resources within 4.5 days: faxes arc acceptable. (AK stauues 38.05.020, 38.05.035.41.08.02b, 46A -S.020 and AK regulations I 1 AAC 93.1}0). DNR! Division of Mining, Land and "ater, 550 w 7th Avenue, Suite 1020 Anchorage. AK 99501- 3562 Phone(907)269-8439 and UN, (907)249-8947 Within the City of Anchorage, it is required that a copy of the wel I log be sent to the appropriate city office within Gil days and that another copy of the well log be sent to the welliproperty, owner within 30 days. Pcrmit Number. class C Date of Issue:_ Parcel Identification Number: Is well located at approved permit location? ( X) Yes or ( ) No Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Section 4700 South Bragaw St, P.O. Box 196650 Anchorage, AK 99519-6650 www.rituni.ot T`wonsite (407)343-7964 Attention: Property owner shall provide a well log to the DSD within 60 days of well completion. Permit Number SW0. 5042-5 Ditc ot'issue Nour08_.2005_ Parcel identification Number: 0213 -.—J_71— -_09„_ Is well located at approved gcanit location" (X) Yes or ( ) No k a Well Log p t jry "Vef.'✓w{t rze6, =re, ttir=,.4 `oo7 .#'� c�5a; 13 iltan� 5 ancd 03. 15 x2006. Cozn�>Icrc 03 e 16 :2006 c,E},t3><,n r snaa;t sign_ at.c�c�: LO Pruperty0;vnci Name address: Bill lNilkinson 16701 Ransom Ridge nchorage Keno Hills 1 2 Anchorage, Ak. 99516 eddian 'lewn;ship Range 5c�3ion '/<o€ Aof _ % of BOREHOLE IDAi A(from top of casing)Depth ( Drilling method: (X) Air rotary. t ) Cable tool, Orhel Material: i`ype. L`oiar & wetness :meront Tar � tk'eil use 4 7 Puhlic suppiv. ( X) DrnnaStic. Oihrr -11 stickup 0 2 Depth ofholc: j ti, Casing stickup: �_ ft Casing type: Steel,_--_—. thickness: .250 - inches z Casinj dia ete : 6 incites Casingdepth: -54 rtdirt - -- ---- &gravel 2 $ Liner tvpe: - Diameter: _-. - inches Depth: __ fl clay & rock 8 14 Static tato (f'r'ont tap of casing): 34 fi on03_ _16 2006 Pumping level .& yield: feet atter hours at epm Recovery rate: _ 6 _ snm- Method ofts sting: airlift sand &gravel 14 37 Deoclopmcnr incthod: airlift Duration: 1 hour coarse gravel w/little h20 37 41 Wall intake opening type: ( ) Open end. ( X) Open hole. Other Screened Start _ — it, Stopped silty clay & rock 41 1 50 Screen tv C Perforated: Start: - f3, Stopped: - fi silty fine gravel w/little h20 50 51 ' Starr: - ft. Stopped: _ - It bedrock 51 166 Grout type:, bentonite Volume, - — — i Depth; from around surface . to _.._ 20._ _ _ _.ft e Purap intake depth: _--- It Pump size: hp. Brand tunic: Was well disinfecred upon completion? (X) N'cs, ( ) No I _ Method of dis nf: Cii0n:CalciUm_tiypochlorite--(.Chlorine)_. Drillerconnllents., disclaimers: .......... ..._.......... .................................. I Water entering thru.fractures. atdepths of 52',.75',1 95' and_140' for, a total 6 gpm,._, .... - - - ............. - - ....-_.._..-_ ............- ..._.. Well driller name: Johnny -Kay ... ............. ............ ....................... ... Company name: ....Hefty Drilling, Inc. Madmgacidrtss 3540AkulaDr � cry Anchorage __ State Azo Zip 99516 Phone number : ( 967 ) 345 - 0593 fax:345-4700 -� 1 Drillers signature: Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Section 4700 South Bragaw St, P.O. Box 196650 Anchorage, AK 99519-6650 www.rituni.ot T`wonsite (407)343-7964 Attention: Property owner shall provide a well log to the DSD within 60 days of well completion. Permit Number SW0. 5042-5 Ditc ot'issue Nour08_.2005_ Parcel identification Number: 0213 -.—J_71— -_09„_ Is well located at approved gcanit location" (X) Yes or ( ) No k a