" ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Name DISTANCES
,D/yN ~"'/ 1~'4/..N r~,ol,,l ~ '-/ ~,nM~O SEPTIC ABSORPTION
Address,,,u~,~ ~ TANK FIELD WELL
~ LOT LINE ~o + ~+
~-~ ~R ~ ~ ' ~o ~o+
kOt ~ ~10~ ~ SuB~wlmon
~ ~E~O HiLLg ~ ~ FOUNDATION I~ ~5
Townshlp, Range, Secbon AS-BUILT DIAGRAM (Show locahon o~ well, sephc system, property hnes, foundahon,
TAN
KS
~ SEPTIC ~ HOLDING ''
~nu,~,~,.~ C~..o,,.,n ~,,o~. I~C * I
M~terial No. of Compa~ments
TYPE OF SYSTEM
~T~ENCH ~ BED ~ W. DRAIN ~ OTHER
Depth tO pipe botlom from Total depth from original grade
or,o~n~ ~r~. ~ FI ~ FI
Fill added above original grade Gravel depth beneath p~pe / /.
FT ~ FT r~,~ .i ~' f~ ~,~Aj =~,,h
~ellength Gravelwldt, i .'~ ' / '
~ FT ~ FT ,'
r
/
/
Total absorphon area D~stance between lines I
/ /
Number oft .... J S°ll rating P,pe material
/
/
/
WELLS
7 PRIVATE ~ OTHER Jldentifv) I ~
Classd~cahon (A,B,C) Total Depth J Cased to
~ ~ FTI FI
Idstallel Date Installed:
REMARKS:
Sca
II1~
e
..... ' ' 4 ;n -~E~I~EER~'S~L
I¢l, 4 l~k ~0% Inspections Peffofmed by: , ';"¢';'~(¢:: O? ?:¢' '~"~
cedily t~al this inspeclion was pedormed ac~or~ln~ lo.ill,
~ ~"" .~', ~: ..... , ~ .-,~ ."
72-013 13/85)
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2O
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
t41i.~.T~ownship, Range, Section:
SLOPE
5,oO'
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water Alter
Monitoring? Date:
SITE'PLAN
Gross Net Depth to Net
Reading Date Time Time Water Drop
COMMENTS ~0 ~' ]
PERFORMED BY: ~--'~ ~__~ I CERTIFY THAT/THIS ,TEST WAS
ACOORDANCEW,T. AL,_STA ANOMUN,O,PA'G' ,DEL,NES,NEFFECTONT"'SOATE. DA'rE:
PERCOLATION RATE minutes/inch),P, ERC HOLE DIAMETER __
TEST RUN BETWEEN __ FT AND __ FT ~.~
PERFORMED IN
72-008 {Rev. 4/85)
CONSULTING ENGINEER
203 W. 15th AVE 'C" SUITE 203
ANCHORAGE. ALASKA 99501
TELEPHONE: {907) 279-3916
I NSTCd..J,.., I:::'ER Ehl(:.:~ I NI'.-,'!:IERS A'T'T'ACHf.'~;]() :~')E:S ;t: 13!q ,, hll:.lT I I'.':Y DHHS PR t OR "FO
!!!:A'~C;I,..I .;. I\t,~il;t::tEC'T' ]: O1\1 ,, TH :[ S t::"I~!i:RI91 T ]: S ;t: S,~iiiUED FOR THE: PROPOSIEJ) 4,
S];NGI.,..Iii[ :'¢:~I"iILY DI,4Ei:I,..L..I:IX!J3 C)hlLY ~'.~ND EXI::'IFRES O1'4
I^flEI_t,.. L. OE') "I"E) ;EH!E F'I::;~O'CI.'J)ED t4I'T'H
ALASKA E UIRO m nTAL CONTROL $ RUICES, InC.
~noin¢¢ri~0 ~ (~nuironmenlal Studies
SPECIFICATIONS FOR A TRENCH-TYPE WASTEWATER DISPOSAL SYSTEM
LEGAL DESCRIPTION: LOT 1, BLOCK 4, KENO HILLS ADDITION #2
1.0 GENERAL
1.1 The Drawings, sheets 1 thru 4, shall be a part of this
specification.
1.2
Ali materials and workmanship shall meet the
requirements of the Municipality of Anchorage,
Department of Health & Human Services (DHHS), the
conditions of the permit, and all applicable rules
and regulations currently in effect.
1.3
All elevations and depths are advisory, and are to
be verified or modified in the field by the
engineer or inspecting agency.
1.4
It is the responsibility of the property owner or
installer to adhere to approved designs for
installation, maintain the specified separation
distances, and have the appropriate inspections.
1.8
It is the responsibility of the property owner or
installer to report to the engineer any observed
conditions which would put the system in violation of
state or Municipal regulations.
1.6
If the installation is not inspected by an AECS
engineer, AECS will not be responsible for the
installed system. An engineer at AECS should be
consulted prior to construction to determine the
number of inspections that will be required and to
explain what these inspections will involve.
2.0 SEPTIC TANK
2.1
If there is an existing septic tank, it may be
used it if meets the capacity requirement for the
residence and the approval of the MOA.
2.2
The septic tank shall be a UPC-approved
two-compartment tank, constructed of 12 gauge
steel with bitumastic coating and set level on
undisturbed soil. If the tank is buried at a
depth of 4 feet or less, it must be insulated with
an overlying layer of 2 inch burial type
polystyrene rigid board Insulation.
2.3 The septic tank and trench shall be a minimum of
2.4
2.5
2.6
2.7
100 feet from any private well or body of water,
150 feet from Class "C" wells, and 200 feet from
Class "A" or "B" wells, unless otherwise
specified. Less than the required separation distance
must have prior approval or waiver by ADEC or MOA.
The septic tank shall be a minimum of 5 feet from
the house foundation, and a minimum of 5 feet from
the absorption area.
Piping shall be fitted with a mechanical
watertight calder coupling on the outlet and inlet
of the septic tank. Piping shall be 4 inch solid
PVC ASTM D-$054 or cast iron, sloped a minimum of
1/4 inch per lineal foot. If the piping is buried
at a depth of 4 feet or less, it must be insulated
with an overlying layer of 2 inch burial type
polystyrene rigid board insulation.
Cleanouts shall be installed as designated and
capped with air-tight rain caps (Jim Caps or
equivalent), and extended a minimum of 1 foot
above ground level.
If a lift station is required it shall be a
combination lift station septic tank per Anchorage
Tank and Welding, Inc. design. Specifications and
design drawings are on file with the Municipality
and the engineer.
8.0 ABSORPTION AREA
3.1
The gravel for the trench shall be 0.5 to 2.5
inch, screened rock with less than $ percent
passing the No. 200 sieve. Ail substitutes must
have prior DHHS approval.
3.2
The bottom and sides of the excavation shall be
raked with the backhoe blade to ensure that it has
not been compacted during excavation. The bottom
elevation shall be level.
3.8
Monitor standpipe(s) shall be placed as shown in
the drawings, and shall be 4 inch rigid PVC ASTM
D-$054, or cast iron. The section shown with
holes may be 0.§ inch holes drilled on 6 inch
centers on opposing sides of the pipe, or a
regular section of perforated sewer pipe clamped
to a solid secti~on with either a no hub coupling
or a solvent joint. A rubber rain cap (Jim Cap or
3.4
3.5
3.6
equivalent) shall be installed over the top of the
pipe,
The distribution pipe shall be perforated 4 inch
PVC with a minimum crush strength of 1500 pounds
and shall meet the approval of DHHS for use as
drainfield pipe. All distribution pipes shall be laid
level.
Trenches may be paralleled, but must have a
minimum separation distance between the trenches
of 10 feet or 2 times the gravel depth (which ever
is greater). 75 feet is the maximum allowed
linear length of any trench.
If the final grade over the trench is less than 4
feet above gravel, insulation is required, using
burial type polystyrene rigid board insulation.
There shall be 1 inch of insulation for every foot
of soil less than the required 4 feet of cover,
but there must be at least 24 inches of soil cover
even though insulation is used. The solid pipe
extending from the septic tank to the dratnfield
shall also have a minimum of 4 feet of cover or an
equivalent layer of insulation to prevent freezing
of the line.
3.7 Filter fabric is required.
4.0 INSPECTIONS
4.1
A minimum of two inspections are required for the
installation of the trench. The first inspection
will be of the open excavation to assure that the
system is installed in the proper soil strata,
correct depth and meet minimum specified design
parameters.
4.2
The second inspection will be after placement of
the gravel, monitor standpipe and distribution
pipe to verify proper installation and position
prior to backfill.
4.3
The inspection of the septic tank installation can
be incorporated with any one of the above listed
inspections.
4.4
The lift station will require either an MOA electrical
inspection or certification by a licensed electrician,
depending on whether the building code applies to this
part of the city.
CONTROL SERVICES, INC.
1200 West 33rd Avenue, Suite B
ANCHORAGE, ALASKA 99503
(907) 561-5040
S.EET.O. /
CHECKED BY. DATE
SCALE
i.'.': ~;~" ~': ~.'."~ ; i il. i. i ........... ,; ~
........ ~' I ! i i ~.,~ I~/~I" ~,~,~i...~i......~.....~..~..~.~~.....i i i .............. ..............
............ ill!.' ............ .......... ............ .............. ~ ~.i~~ ~..i....~~
I i. i~~ ~ ~ ~z~ ~:~ ~.......i..~%...........~.i~..~.%.d.~........L.......! i i i .i ............. .............. ............. .............
...... I/~'~ ~ ~-~ ,. ~ ~ i...~ ........ i_ ~./,'. i ................................................................... i ............. i .........................................
Municipality o! Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
DATE PERFORMED:
LECA' DESCR,FT,O.: '~/ Z."'A~"O #'//' '~Z/~ Z
~,e ~,~f
1 ,5'~1,t ~/
2
5
6
7
8
9
10
11
12~
13
14
15
16
17,
18-
19-
20-
Township, Range, Section: 7-//,4~ ,~',~'bO ~'//
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
S
L
IF YES, AT WHAT ~ 0
DEPTH? p
E,
Depth to Water Alter ~.
Monitoring?
""7 Date:
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE __
(minutes/inch) PERC HOLE DIAMETER __
TEST RUN BETWEEN FT AND
COMMENTS
FT
!
72-008 (Rev. 4/85)
· , t E.'Z. CLU810~] II,n. TE: It Is the 0wners
,~ ~.~. ~".~, ~'~ ~, responsibility t~d~ter~n~ the
~;>~'~ ~" ~ ~
;:~".~.:,:~ .....~'*~,~. or re~tr[ct~9;,s wTdc~do not ~pp~sr
~, C). &~ ~l .~:..i.~
6,'. · LS-7625
4~
ol
N
I OH.~.7~V ~'~ ~T, ~ICATION' I ~h~'~"~,~:~~' '~j~s''''urveYed the propertv shown and de-
~:~.~.. ..... :~ 'hat the'lmpro~e~'~reon are with n the property lines and no
encroachment, exl,t other than not,d. ~/~ --p/~
PLEASE NOTE: I, I, the contract LEGEND: ~T
ENGINEERB' PLANNER8 · BURVEYO of'°r'l foundetlonreSp°nslbllltYln tOrelationCheck tOPto 5/8"HUB REBAR& TACK
440 WEST BENSON BLVD. finish grade and buBding set- MONUMENT
CHKO.=
backl In relation to lot lines AL.CAP
ANCHORAGE, ALASKA g9503 562-5291 and ealementl. PK NAIL
....... IRON.PIPE
LEGAL DESCRIPTION: I" I = ELEVS.-DATUM
ASSUU~O
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
HAA#
GENERAL INFORMATION
Complete legal description
LOcation (site address or directions)
Property owner
Mailing address
Lending agency
Mailing address
Agent
Address
Day phone
Day phone
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual well
NOTE:
Community well
Pub ic water
If community well system, provide written confirmation from State ADEC attest-
mg to the legality and status of system.
4, TYPE OF WASTEWATER DISPOSAL:
NOTE:
Individual on-site
Holding tank
Community on-site
Public sewer
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev, 1/91) Front MOAW21
STATEMENT OF INSPECTION BY ENGINEER
As certified bY. my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm T~A-u ,~o ~). ~)~-5~-/~ ~J ~.c~'~, Phone &q~-~7
Address ~'-~ '~ ~ /~o,~ ~'~ /,~/~'~//~, /~/C ~(~ 7
Engineer's signature ~~.2~ Date f/~//~2.....-
DHHS SIGNATURE
Approved for ~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Date ,,~--~// ~ ~2
The Municipality of Anchorage Department of Health and Human Services (DHHS} issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DH HS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or Omissions in the professional engineer's work.
72-025 (Rev, 1/91) Back MOA ~1
Legal Description:
A. WELL DATA
Well type
Log present (Y/N)
Total depth I Z~"
Sanitary seal (Y/N)
, Municipality of Anchorage
Dep~artrfi~n{ of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Parcel I.D.
If A, B, or C, attach ADEC letter. ADEC water system number
/V/ Date completed ~'~<~'¥ /e~'~ Driller
Cased to 5 2~' w-- Casing height
Wires properly protected (Y/N)
Date of test
Static water level
Well flow
Pump level
FROM WELL LOG
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Public sewer service line /f~'~' ~-
g.p.m.
AT INSPECTION
m
oz
i,O g.p.nl~.1 ~ ~
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
1o~-+
WATER SAMPLE RESULTS:
o~$/~p~-
Coliform
Date of sample:
Nitrate o,/..~/~p~z_ Other bacteria
Collected by: ~'~'. ~,a~
B. SEPTIC/HOLDING TANK DATA
Date installed ~//~/~ o Tank size ) 2.-~,-'z:> Compartments ;'-
Cleanouts (~/N) .. ~' Foundation cleanout (Y/N) ~ ' Depression (Y/N) ~
High w~te~'ala~m;(y/N) ' ~/~ . Alarm tested (Y/N) ' '~
SEPA~AT ON'D STANCE8 F~OM 8EPTIC/~ TANK TO:
Well(s) on lot /~-~ +'- On adjacent lots
Toproperty line ~- ~ + Absorption field.
Surface water/drainage /f~-'~ ,~gxJz3 L~ ~ ~
Foundation
Water main/service line '~-~
72-028 (Rev, 3/el) From MOA 21 CONTINUED ON BACK PAGE
Date installed
Size in gallons
Vent (Y/N)
High water alarm level
"Pump on" level at
Manufacturer
Manhole/Access (Y/N)
"Pump off" level at
Cycles tested
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot On adjacent lots
Surface water
D. ABSORPTION FIELD DATA
Date installed
Length
Total absorption area
Depression over field (Y/N)
Results (pass/fail)
Peroxide treatment !?st 12 months) (Y/N)
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
System type
Well on lot /5-~
To building foundation
On adjacent lots /~ ~:*'~"
Surface water /t~
Curtain drain ,,~ ,~,,z..~-
Soil rating
Gravel thickness ~ Total depth
Cleanouts present (Y/N)
Date of adequacy test -~
for bedrooms
If yes, give date
On adjacent lots ?~- Property line
To existing or abandoned system on lot
Cutbank ,4~.,F Water main/service line
Driveway, parking/vehicle storage area
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signature ~~~
Engineer's Name .
/ '/ - .
HAA Fee $ Waiver Fee: $
Date of Payment , ~- ~ ~-- ?~~ Date of Payment
Receipt Number c~,~ .~ ~ ~ Receipt Number
72-O26 (Rev. 3/91) Back MOA 21
D. R. DAYTON, P.E., R.L.S.
HC 78 Box 1026 Chugiak, Alaska 99567
(907) ~6~t~ ~T~
696-2417
March 19, 1992
Municipality of Anchorage
Dept. of Health and Human Services
Re: Lot 1, Block 4, Keno Hills ~2
Health Authority Approval
Gentlemen:
The well on this lot was apparently drilled sometime in the 1970's.
There is no log and the driller is unknown. The depth of the well casing is
not known. The casing is' visible when the water level is down to 57' below
the top of the casing.
No adequacy test was done on the absorbtion system as the system is
less than 2 years old and probing indicates little or no sludge in the
tank. The house is in the final stages of construction and the system .u~s~~
since construction has been by workmen, not a normal household usage.
S~n~erely, /~
D. R. DAYTON, P.E., R.L.S.
I-IO 78 Box 1026 Chugiak, Alaska 99567 696-2417
March 19, 1992
WELL FLOW TEST
Legal Description: Lot 1, Block 4, Keno Hills ~2
Date of Test: January 29, 1992
Depth of Well: 125'
Static Water Level: 47.3' belw top of casing.
Standards: Municipality of Anchorage, 150 gallons per day per bedroom.
Test: The well was pumped for 6 hrs. 15 min. at an average rate of
1.6 gallons per minute°
Results: The well produced the required 600 gallons in 6 hrs. 15 min.
and is adequate to meet the Municipality of Anchorage standards
for a 4 bedroom home.
5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343 FAX: (907) 561-5301
~-'-~,' %~.:~ ~?..:.i(P ~i~ :: i H:.:nx: }27i2
Sample ~OUTI~Z SA~LZ COLLECTED ~¥: DL DAITON.
ND- None Detected "Sea Sample ~ema:ks Above
N).- ~ot ArmlTzed L?-Lese Than, ~T-Gre~ter ~k~n
~ S--~-~ Member of the SGS Group (Soci~t~ G~n~rale de Surveillance)
CHEMICAL & GEOLOGICAL lABORATORY
A DIVISION OF COMMERCIAL TESTING & ENGINEERING CO.
5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343 FAX: (907) 561-5301
ANALYSIS RESb~TS for INVOICE % 50568
Che~ah Ra£.# 92,0283 Sample { I Matrix;
Client Sample ID
PWSID
Collected
Received
?reserved with
RD LOT I BL 4 KENO HILLS
UA
JAN 23 92 { 14=00 hrs.
JAN 23 92 4 19:40
AS REQUIRED
Analysis Completed : JAN 24 92
Laboxatory Supervisor : aTE?BEN C EDE
Released,By:
Client Name :DAVID DAYTON, P.E.
Client lcct :DAVIDDA
BPO{ ~
Ordere~ Ey :DAVID R. DAYTON
PO{ :NONE EECEIVED
Send ~aports to:
1)DAVID DAYTON, P.E.
Parameter R~sults Units Method Allowable Limits
NITRATE-N 0.13 mO/! EPA 353.2 lO
Sample ROUTIN~ SAMPL~'COLEECTRD EY~ D.R. DAYTON;
1 Tests Pe~fo~med See Special Inst~uctions Above UA-Unavailable
ND- None Detected "See Sample Remarks Above
NA- Not Analyzed LT-Lass Than, GT-Oreater Than
Member of the SGS Group (Soci~t~ G~n~rale de Surveillance)