Loading...
HomeMy WebLinkAboutKENO HILLS #5 BLK 6 LT 3Keno Hills #5 Block 6 Lot 3 #020-171-33 ra Municipality of Anchorage Page 1 of 3 Development Services Department Building Safety Division On -Site Water and Wastewater Program, 4700 South Bragaw Street P.O. Boz 196650 Anchorage, AK 99519-6650 www.cianchorage.ak.us (907)347-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW040308 PID Number. 020-171-33 William Hiatt Wastewater System: Tank Only Ad . 17715 Ashland Drive Anch. AK ggs16 ABSORPTION FIELD r., a. aewoo•. 345-7602 Four 4 Existing Trench LEGAL DESCRIPTION 5"Rav TOIWD•Obkenmgy R•a• GPD/FeFI. 111 A Lm alb ry .06 D•Petbpq Edtvrthgn argrW V•O• GravN OepN C�reN P9• 6 3 Keno Hills Ft. FL To.rrlrp Nares FA.ao.aabo ;WWgr w •.w Lrptn. Ft. Ft. Well: Existing Well wMw NunOar Yn•e O•ha•n 1~ FI. Fl clnaLr�oan (Prteat•. A a. C)' TOW Dean CassO b: r•a W FI. Ft Ft' DNr DM•DrWW sm. Water L•.•1 Ft Acreage Systems 8/4/2004 rWe PurVSMaI rata �o Gand rJ05-DF51 TANK G A L/ GPLI FI Ft SEPARATION DISTANCES ® Septic ❑ Hoeing ❑ S.T.E.P. ❑ Other: TO Septic Absorption Lift Holding uwPdvate From Tank Field Station Tank Sewer Line Anchorage Tank 1,250 wa1 100' >100' N/A N/A >25' Steel Two (2) &,%wwa 1001 >1001 N/A N/A LIFT STATION — NONE ON LOT La LM >51 >101 N/A N/A GW F•urtlYan >5' >101 N/A N/A urV an . utvw b „ in. culaetor•e None oted •a o maO Dy Ror"Its Tank Only Replaced Under This BENCH MARK Permit. Existing Se tic Tank Door Stoop. Northwest Corner of House. Pumvied,Crushed and Buried On Site. AaautrO ENvalbrc 100.0 FL Engineers Stamp y or49th 0 l Inspections performed by: NZA Dates: 1" 8/4/2004 --' -: MICHAEL •E . rA ANDLR5 j �i sr�+, No CE -4381 2nd 8/4/2004 '%" J� •••.�0 Department of Health and Human Services approval Reviewed and approved :, .4 z G k Ashland Drive 7 20,2 8 e+ ■P- E �2 |§• f 6( t ({§ z #co CA Z to O� Cl) f■k/ § Eƒm$ q E 7770 C \' §eco \{/� � a @ 7)m IR \ 2 \)w co k\ �g ma 290.00 J 2 ( CD \ Q k Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SW040308 PID No. 020-171-33 ting Trench NEI Septic Tank Only Placed Under This Permit. Existing Septic Tank Pumped, Crushed and Burled On Site. 3 49th t'e PROFILE AS -BUILT '•, No.aH� Scale: 1' • tm MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SWO40308 Legal Description `KENO HILLS #5 BLK "6 LT ' 37 Design Engineer: 0014 Anderson Engineering Owner Name: WILLIAM HIATT Owner Address: 17715 ASHLAND DRIVE ANCHORAGE. AK 99516 - Ely iqa Date Issued: Jul 30, 2004 Expiration Date: Jul 30, 2005 Parcel ID: 020-171-33 Site Address: 017715 ASHLAND DR Lot Size: 108464 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: R] Disposal Field ❑Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By. Date: a 'G)- (Y4 Date: 713-010 y Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ek.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020.171.33 Permit Number SW Property owner(s) William Hiatt Day phone 345.7602 Mailing address (1)17715 Ashland Drive Anchorage, AK 99516 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 3. Block 6. Keno Hills Subdivision No. 5 Legal description (Section, Township & Range) Lot Size 101, QU!A Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms _Four (4) Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ED THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Date of Payment Waiver Fees: Date of Payment: Receipt Number. FJ )C Jp Receipt Number. (Rev. 12100) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX July 27, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 3, Block 6, Keno Hills Subdivision No. 5 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The septic tank on Lot 3, Block 6, Keno Hills Subdivision No. 5 is failing and must be replaced. We are proposing to replace the tank with a new 1,250 -gallon tank to serve the four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic tank to serve the home. The attached Site Plan and backup documentation identify the location and configuration of the existing septic system and the location of the new tank. Also identified on the plans is the existing well on the lot. The new tank will be placed in the same location as the existing tank with the exception that it will be 7' to 8' from the foundation. The existing tank will be properly disposed on the property or removed from site. The drainage patterns will be maintained after construction. The ground surface on the lot slopes at varying grades. The new septic tank will be constructed near the location of the existing tank and as parallel with the slope of the land as possible in conformance with Municipal requirements. The new septic tank will be constructed a minimum of 10' from the existing water service on the lot and those on the adjacent lots and will not conflict with other facilities in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing Lot 3, Block 6, Keno Hills No. 5 July 27, 2004 Page 2 of 2 septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments i 6 f r _•f F W NiE+r I /0I : 00'061 fi��s'�.... i....!�•• LO c0 Z U N O J m _J = M O� w OJ Y N rl ? 3 M a f'ZYY a ® W co to m C 3 FO- FO- EE w LO ' '- t0 m LO < i0 N O C"aO N 8=,C) C,4 E o=. 7 V Z C LL Q ,: m. a ,A J a �CN O O• - a m� N � www 00061 aniaa puelysy Lot 3, Block 6, July 27, 2004 Page 3 of 3 Keno Hills No. 5 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. ' Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Lot 3, Block 6, Keno Hills No. 5 July 27, 2004 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: - NOT REQUIRED The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. ONSITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 3, BLOCK 6, KENO HILLS SUBDIVISION NO.5 GENERAL: 1. The scope of this project includes the pumping, crushing and abandonment of the existing septic tank on the lot and the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the site plan. Work also includes the placement of 2 post tank cleanouts and a new foundation cleanout if one does not currently exist. The existing septic tank must be disposed in accordance with Municipal and ADEC requirements. The new septic tank must be constructed a minimum of 100' from any surface water and 100' from the existing well on this and adjacent lots. A minimum of 4' of cover is required over the septic tank. In lieu of cover 2" of direct bury insulation and 2' of cover may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 -gallon septic tank must be procured from a certified septic tank manufacturer if the existing tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264.4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE ^'S�I EW ❑ UPGRADE MAILING D ESS LEGAL DESCRIPTION Cr LOCATIOW NO. OF BEDROOM Uy DISTANCE TO: WAell Absorption area ! Dwelling PERMIT NO. Q 1- z y Manufacturer Gt� r t� Material f�. No. of compartments Z_ Liq. capacity in gallons IF HOMEMADE: Inside length �- Width Liquid depth _jaZ DISTANCE TO: Well Dwelling PERMIT NO. = Z F Manufacturer Material Liquid capacity in gallons w = DISTANCE TO: Well Foundation i Z 5• Nearest lot line - PERM�,I+T NO ?Y9 7 : Ju. Z Zw F — � No. of lines j Length of each a Total length of lies Trench widt inches Distance bet een lines ;. < D Top of tile to finis grade t� Material beneath the 1 "2 inches Total _ fective absorption area ' W a Length Width Depth PERMIT NO. i F Wa Type of crib Crib diameter Crib depth Total effective absorption area LU DISTANCE TO: Well Building foundation Nearest lot line Class Depth Driller Distance to lot line PERMIT N0. W :2: DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS SOIL�TTESTRA/TING U� U Z 0 INSTALLER to } / oh ` �. v �, U✓V�/. /K , REMARKS a n J�rn �� `"5� APPROVED DATE LEGAL 2-u13 IHev. S//6) u 00502 344=7714 .. y,.! SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH O 2'U Teei DRILLED AT THE RATE OF MOOPER FOOT. PROPERTY OWNER AIU Midd ias M44tt 6SQ¢--�. 16th Rj B _99504 333-5051 LOCATION OF WELL SITE Lt. 3 44A2 6 Xeno (j DRILLER _ Be"Ze Ciau4 ale Rampatt Atttt L" Glotko. WELL LOG: 0-17' Snait bou.tdete & 4an4 gtoa►" 17---36' Coatae quwat w4th 35% clay. bLulet. Steed afar inch ca44ru4 dktuen. to &e%at at 39 .deet, three Aet 4mo bed tock. ULGGil!g moe ,therL cant4mLed ung a B,taaond d Ut. TU4 each Ae4 ha rd bedtack. 44 the Cao.ing a ihat�o tett an. 36**"225' Bedtock.. R aediaeeataty, .tack. Ito motet ptodurtdan 4how4aq ure,t,LG 16$ Aa 1/2 VM Uptaudnq..to 1 1/2 WE by 200 ./.t.. Thin. ate" 4 po,toa4 type •tock. Uoa. 210 to 2254 4hot64 an tn Aeaee of two WN 4a a gtalull ,t. & po4ou4 Total. water V444d 4how4 a good 3 .to 3 1/2 &sM & 4hou d 4aaptove to 4 �;1'M e4th u4e. 200 gaUon4 pet hour ptoduc ioa & 4houdd 4spaouc. Water. a Ao Caae44 back wttAJA 25 ®1, 4"A" ove t nLght. 200 A 04 wat44 4twuUng at 1.6 �N 3/4 h&ue 4utweA44ble pineµ 4houtd ire tr&4ta ted 10 ,to 15 botio&. The ove t alt depth alt the ecet.L 14 230 �.t. Thank YOU 17"* AMA B" AlaU pa6d JA &U by. R,t. Btu 16iat t Dates Oct. 16th, 1983 Be,tnde CLaw4 of. lamps" 11tat4 e4 trrott o r`� Department f Health and Environments Protection 825 Street, Anchorage, AK. �J9501 264-4720 Permit #�'�� # # # HANDWRITTEN PERMIT # # # WELL AND/OR ON-SITE SEWER PERMIT rSv Applicant: 2yi%1-An-7 0/� 1010 2iuA_ //A7� Mailing Address: Geo( cc_'/4f'` h4c)L jg4t,6 Location: L07` 3 6(r_(, kl_(�,yyo H; ((S Phone Number: 33 3-51 . 1 Legal Description: TJI N f2 Lot Size: — Type of Soil Absorption System Is: Trench: Drainfield: i/ _ Seepage Bed: Holding Tank: Maximum Number of Bedrooms: Soil Rating(sq.ft/br) Rs- The S The Required Size of the Soil Absorption System Is: DEPTH �� LENGTH 3 7 GRAVEL DEPTH 3.%� WIDTH S The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE _ /2S`0 GALLONS # # Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * # * TWO(2) INSPECTIONS ARE REQUIRED # # # Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 'feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper_ installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 u 3 # # # I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Signed: Issued by: �n--G--- Applicant / / U Date: SWP/024(1/81) 06J— sUi LS LOG `MUNICIPALITY OF ANCHORAGE -. DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION El PERCOLATION 825 L. Street, Anchorage, Alaska 99501 264.4720 TEST SOILS LOG — PERCOLATION TEST PERFORMED FOR: & iI H; ptI" DATE PERFORMED:Ayj 3 1953 - - LEGAL DESCRIPTION:_ Keno Hills RIK 6 Let 3 TlIWR3i, moR STB30z� p pT SLOPE SITE PLAN 10 WAS GROUND WATER S 11 e .ENCOUNTERED? N� L s . O 12 P IF YES, AT WHAT s E 13 Cia1�0S dove DEPTH? _ 14 16- 17— gas 6 17 rC.Raid, J 19 �tJ'•. No. 2251•E F'9 'h•••wNw�ww'' �p4110FESS0 Reading OF E Co L�o go ;c Sol Net Depth to Net .� S{Iee t 1 i Water Drop " CGk) tilt Sil� S,n.l� gra✓!' 2 - i Q.' a.b.,eei.nt �66ICS 3 4- 6 6- 7 8 6S aLovt_ - 10 WAS GROUND WATER S 11 e .ENCOUNTERED? N� L s . O 12 P IF YES, AT WHAT s E 13 Cia1�0S dove DEPTH? _ 14 16- 17— gas 6 17 rC.Raid, J 19 �tJ'•. No. 2251•E F'9 'h•••wNw�ww'' �p4110FESS0 Reading Date Gross Net Depth to Net .� S{Iee t Time Time Water Drop i Q.' 20 �'��ea�te+`� PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND FT / COMMENTS Se -Porn c3 ' -jo 8' and -Gm 9V2' 'Fe I Z a i V �sva 11!4 rn-1ed tZ 8S t7 �44 PERFORMED BY: D Art CERTIFIED BY: DATE: 72-008 (6/79) S{Iee t / og a2 SiteC �.S SOILS LOG MUNICIPALITY OF ANCHORAGE I� DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264.4720 SOILS LOG — PERCOLATION TEST PERFORMED FOR: V�I� �la DATE PERFORMED:_2 1193 LEGAL DESCRIPTION: Keno thin B10.tc 6 pct 3 TIItJ�-3�J MMA TT 953 o-zy - SLOPE SITE PLAN F E (p L.) Organ+C SeG) (GTA) 6D n �r t sravell'\ vl } "Vlar ICAWIS a -A SaAd (ML) ve,y dense ': rRy 9raverlc� d.t sc�} *!4911.4W *14 WAS GROUND WATERS N ENCOUNTERED? O L O P IF YES, AT WHAT E DEPTH? le kr FT -Reading Date - Gross Time Net - Time Depth to Water Net - Drop JPERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND FT PERFORMED BY: Carlo.g Co"Aw- CERTIFIED BY: DATE: 4 s , AV AT AT FILLS OUT UPPER HEAL ;ONLY Property Odvner I F. Time Phone fy0-,/ Mailing Address.- :. y, .'-� l�� , �_ � Zip Code _-)) tr 3? Buyer A Date Address - Zip Code Lending Institution I_ )I I%- A Phone Address Zip Code Realty Co. & Agentlj Phone Address Zip Code Legal Description uT _� 7,L cc /._ iv G I-) 3 L{, S Sv 1'; j) %� n pr% Street Location -7 —11 t -} (, , t n! 1] e-.5/.✓(� �E a WU4111-�' Type of Residence . Dingle Family 'CONDITIONS OF APPROVAL ❑ Multiple Family No. of Bedrooms— LL�- /inti -'- �Y- [ !=v vrr r ❑ Other // ( ) CONDITIONAL APPROVAL - Water Supply ndividual ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. ❑ Community For wells drilled prior to that date, give well depth (attach log if available). ❑ Public Utility Sewer 14 P-Iff-dividual Year Individual Installed: Q ❑ Public Utility When Connected to Public Utility N1 14 ❑ Holding Tank . NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector Field Notes: e-.5/.✓(� �E a WU4111-�' (�3) APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL - DATE BY: Soils Rating Date Sewer Installed Well To Absorption Area / (�(j i Well Log Received j Septic Tank Size at p /67 — —b'C f Well to Tank / & p e rz-uez (JIU) Parcel I.D. 020-171-33 Certificate of On -Site Systems Approval Expiration Date: 8/19/2025 Legal description KENO HILLS#5 BLK 6 LT 3 Site address 17715 ASHLAND DR Anchorage AK 99516 Current property owner(s) HIATT X_ The On -site system(s) is/are approved for bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: nitrate concentration in well water is 4.03 mg/L Original Certificate Date: 9/25/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory X Arsenic Advisory Other COSA Approval_June 2022 MUNICIPAI-ITY 02FANCHORAGE Develloorneint Servilces Depari'm ar 1 t ne: Pho -4 & 907"-43-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-171-33 Complete legal description KENO HILLS #5; BLOCK 6, LOT 3 Location (site address) 17715 ASHLAND DRIVE, ANCHORAGE, AK current property owner(s) BILL & PATRICIA HIATT Day phone 907-345-7602 2, ON -SITE SYSTEMS SIZED FOR 4 __BEDROOMS 3. TYPE OF WATER SUPPLY: F* Private Well F-1 Private Well serving 2 dwelling units El Private Well serving 3+ dwelling units 0 Community Well or Public F-1 Water Storage 4. TYPE OF WASTEWATER DISPOSAL: Fk Private Septic ❑ Private Septic serving 2 dwelling units 0 Holding Tank D Community Septic or Publir, Sewer 5. SEPTIC TANK: F* Steel F-1 Plastic F-1 Concrete D Fiberglass Age 20 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: Fj AWWTS 0 Bed ❑ Deep Trench JZ Wide Trench F-1 Seepage Pit Waiver request for: Expedited review requested: Fj Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee$ Waiver Fee $ Date of Payment kh' Date of Payment COSA # 0_5 C Z'-I, I 'S C, Waiver 4 COSA Application —June 2022 Legal Description: KENO HILLS #5; BLOCK 6, LOT 3 Parcel ID: 020-171-33 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1 A. WELL DATA Al Well log is filed with Onsite (or attached) Date drilled 10/16/83 Total depth 230 ft Cased to X Sanitary seal is functioning correctly f R Wires are properly protected Casing height (above ground) 18 in. Date of flow test for COSA 8/19/2024 Static water level at beginning of test 23.5 ft Comments B. TANK DATA Measured operating fluid level in septic tank *49" Date of pumping �j�► 1 >-'4 ❑ Required maintenance completed, if AWWTS Comments: *IN ST1 / 49.75 IN ST2 D. ABSORPTION FIELD DATA Which system tested (date installed) 10/4/1983 W ALL standpipes present per record drawing Total measured depth from grade 8.5 ft (max) Measured depth to pipe invert from grade 3•2 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced - gallons date Any rejuvenation treatment (past 12 months) N/A If yes, enter date Well production at time of test 3.0+ gpm Water storage tank volume N/A gallons Well disinfected for coliform test? Yes ` No Coliform bacteria is Negative Nitrate `" "> mg/L = I'Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by GEG, LTD. r" Date 8/19/2024 1 4 � _ d Adequacy test date 8/19/2024 Results W Pass Fluid depth prior to test 0 in Water added 728 gal New fluid depth 0 in Elapsed time 0 min Final fluid depth 0 in Absorption rate 600+ god FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 42 in Effective depth used 0 in Effective depth remaining 42+ in dt Comments/Deficiencies: *DISTRIBUTION LINE IN DRAINFIELD APPEARS TO BE OUT OF LEVEL BY APPROXIMATELY SEE ATTTACHED EMAIL FROM OWNER REGARDING NO FREEZING (TANK APPEARS TO HAVE 2.5' OF COVER) COSA Checklist June 2022 From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' ❑n Yes if No ft ❑0 Yes if No ft Neighboring Tank > 100' Q Yes if No ft Private Sewer/Septic Line > 25' Q Yes if No ft Absorption Field on Lot > 100' Yes if No ft Holding Tank > 100' QYes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' QYes if No ft a Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' QYes if No ft Yes if No ft ❑ NIA — Served by Community Well (not on lot) or Public Water From Septic/Bolding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' [E Yes if No ft Surface Water > 100' rC Yes if No ft Tank to Property Line > 5' Field to Property Line > 10' Water Main > 10' Water Service Line > 10' F. ENGINEER'S COMMENTS ❑■ Yes if No ft 7 Yes if No ft ® Yes if No ft 7 Yes if No ft Wells on Adjacent Lots: Private Wells > 100' E Yes if No ft Community Wells > 200' 9 Yes if No ft If tank or field is under driveway comment below G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Garness Engineering Group, LTD, (GEG) Phone 907-337-6179 Engineer's Printed Name Jeffrey A. Gayness Date In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the systemis. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the systemis; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well ' or septic system can be installed on the property in the event either of the current systems fail to Worm adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. COSA Checklist —June 2022 VL [ L9 'ffey. vorness, CE— 7953 yS4G�C" ofess1o�°cv #AECC884 MUNICIPALITY OF ANCHORAGE 0EVELOPMENT SERVICES DEPARTMENT � 907-343-7904 On -Site Water and Wastewater Section �= � Fax: 343-70 7 www.rnuni.org/onsite Septic Tank Advisory Certificate of On -Site Systems Approval # OSC241362 Subdivision: KENO HILLS #5 Block:6, Lot: 3 The septic tank for this property is 20 years old. The average life of an asphalt coated steel septic tank is 20 years. Typical replacement costs are $15,000 or more, not including engineering, surveying, MOA permitting fees or site restoration. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. I 30 N89055'15"E I nt 2 373.67 Septic vent (lyp) ° rn deck f 1.0 off 218 2 I LIJI o �I o p M LOT 3 N ❑I Z 2 Q Zt C) Q D z I �m (7 30 ' N89055'1 YE Lot 4 .*.+� OF low MW * * 00 00 o / •fir: t� '! /, A� lizabeth L. Walatka : ,o ,s 8036 - LS • • o��AW AW Qr- A I C • d ��_ any y�{F£SSIONA� `'� EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON FB 22-1, 71-72 UNLESS OTHERWISE NOTED. p9 Storage ---o ""' 3.0 OH � ,N .�'Hou$e o � z2•7 101. Za.0 N 0.9 OH N O Wood wall deck o rvell 374.22 BE 795OD-1 I � 1 � f a� o I � � I� IE I� IC Iw CD a o co 1= m c 1 N co ° to W 0 I `n I �— I T I CD I o 1 CO 1 I I 1 AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following described property: LOT 3. BLOCK 6, KENO HILLS ADDITION No. 5 Anchorage Recording Precinct, Alaska, and that the Improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage Alaska this 7th day of September, 2022, FRED WALATKA & ASSOCIATES, L.L.C. 907-248-1666 Engineers and Surveyors This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer Is limited to the amount of fees collected for services in Preparation of this product.