HomeMy WebLinkAboutKIMBERLY MANOR BLK 1 LT 10Onsite File Ill Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 995J 9-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: _~lx,' 0 ¥O ,y ~ ~ PID Number: Name: ~ ~re~?~ Wastewater System: D New D Upgrade Address: ~d"to ~ De A~o~ ~ ABSORPTION FIELD Phone: No. of Bedrooms: ~ D Deep Trench D Shallow Trench ~ Bed ~ Mound ~ Other LEGAL DESCRIPTION sog Rating: Total Depth from original grade: GPD/Sq. Ft. Lot: Block: Subdiv~ion: Depth to pips bottom from original grade: Gravel depth beneath pipe Township: ~ Range: ~ Section: Fill added above original grade: Gravel length: I Ft. Ft. WELL: E~J T ~ New D Upgrade GraveJwidth: Number of lines: I Oistancebetweenrines: Ft.~ Ft. Classification (Private, A,B,C): Total Depth: Cased To: Tota~ absorption area: Pipe material: Ft. Ft. I SQ. Ft. Driller: Date Drilled: Static Water Levek Installer: I+O~DIN~ ~N~ Date installed: Yield: GPM I Pump Set at: Ft. Casing Height Above Ground:Ft. TANK I SEPARATION DISTANCES a septic ~ Holding ~ S.T.E.P. To ' Septic Absorption Lift Holding Public/Private Manufacturer: : Capacity in gallons: From T~nk Field Station Tank Sewer Lines A~O~ Well' 77 Material: ~ ~/ Number of Compa~ments:l Surface Water >100' LIFT STATION Lot size in gallons: ~ Manufacturer: Line 5~ ' I Foundation ~ "Pump on' level at: "Pump off" level at: High water ala;m at: Cu~ainDrain ~ Pump Make & Model Electrical Inspections pedormed by: BENCH MARK Location and Description: Department'of He--nd Hu Services approval ~"~ ....... ..... c~- ~ . ~:,~-~" Reviewed and approved Date'/ 72-013 (Rev. 9/gl) MOA 25 PERMIT NO: 940433 PAGE 2 OF 2 PID NO: 01707331 SWING TIES FROM: COR."A" COR."B" TO: C.C. "C" 37' 43' C.C. "D" 46' 45' C,O. "E" 52.5' 48' LOT 10, BLOCK 1 KIMBERLY MANOR WELL DECK NEW 4000 GALLON HOLDING TANK ALARM FLOAT -- PLAN VIEW SCALE: 1" = 30' - 0" GROUND ELEVATION 98.4' --/'/' 4000 GALLON HOLDING TANK ~N-~INV. 92.2' PROFILE VIEW SCALE: 1" 5'- 0" LOT 10, BLK. 1, KIMBERLY MANOR 'HOLDING TANK INSTALLATION AS-BUILT INSPECTION REPORT FLATTOP TECHNICAL SERVICES SCALE: AS-SHOWN ' 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 DECEMBER, 1994 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.0. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT NUMBER:SW940433 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:KRETSINGER DAVID OWNER ADDRESS:7640 UPPER DEARMOUN RD ANCHOR_AGE, ALASKA 99516 PARCEL ID:01707331 PAGE 1 OF 1 PERMIT DATE ISSUED:il/17/94 EXPIRATION DATE:il/17/95 LEGAL DESCRIPTION: KIMBERLY MANOR BLK 1 LT 10 LOT SIZE: 34500 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: HOLDING TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~~_~ '~ ISSUED BY:,~ / ....... . ~ -~,,=,,= =,,:~ . -·,,··~,~,.~~¢~, ~l~~ CIV~ & ENV~O~MENTAL ENGINEERING · ENERGY CONSERVAT/ON & ANALYSIS T~EODORE F. MOORE, P.E. ~4530 ECHO ST. PH: 007) 345-1355 November 9, 1994 ANCHORAGE, ALASKA 99516 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to prOvide the required design narrative in support of our application for a permit to install a holding tank on Lot 10, Block 1, Kimberly Manor S/D, located at 7640 Upper DeArmoun Road. The existing soil absorption system is no longer able to accept the wastewater generated in the residence. Soils logs, a site plan, design drawings and specifications are enclosed for your review. Four test holes were dug on the lot in an effort to identify a suitable location for an on-site soil absorption system. As can be seen from the test hole logs, the soils on this lot consist of a thick peat layer underlain by dense, impermeable silt. In some locations there are stringers of silty sand below 7 feet, but these are not of sufficient thickness or consistency to serve as an infiltrative surface, and quite probably are saturated with water during parts of the year. The predominant silt material was generally dense, cohesive and hard. It's impmxneability was confirmed by the fact that a shallow groundwater seep encountered in test hole//3 was not reabsorped in the bottom of the test hole. In our opinion, a holding tank is the only feasible solution for wastewater disposal on this lot. The proposed holding tank will be installed in the vicinity of the existing septic tank, but outside the required 75' protective radius fi'om the existing well. ., The topography of the lot slopes down from nm~h to south at 2% and east to west at 1%. A drainage ditch consu'ucted along the east property line to intercept seasonal runoff was ch3~ on the date the test holes were dug. The proposed project will have no impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any impact on reselwed space/surface and subsurface, or on ddrainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. __ ~ UPPER DEARMOUN ROAD ~ ' . ,, ,,' LOT 10, BLOCK 1 ,, , ,, ;, ,' KIMBERLEY MANOR ~ [ , ~;G ARAG E:!: , '.. -~ LOT 11, BLOCK 1 '. [_~S [ '. EPTIC TANK . - ' '.. INSTALL - - HOLDI~TANK. _ _ ~ T.H. : LOT ~ ~ "~ ~ ~X,ST,,~ , TH [ SEEAGEPIT .................... ~_. ,~' ... .... -._.. ~ ;~ ................... ~ .................................... ...................... / ~ ,- ................................. q .... LOT 4, BLOCK 1 LOT 5, BLOCK 1 ,~ , LOT 6, BLOCK 1 20 0 20 40 60 80 100 ~'"":' 3~ L 10, B 1, KIMBERLEY MANOR S/D ~..........~......_ . ~ SITE PLAN ~%. CE - 3589 ~' .~;~'. 14530 ECHO S~ET DRAWN BY TFM ~ ,,., :,-' ~. ANC~O~O~. ~AS~ 995]6 NOVEMBER, 1994 ~~.~' NOTE: THIS IS NOT A SURVEYED P~T. ~~ ALL LOCATIONS SHOWN ARE APPROXIMATE. TESTHOLE# I LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) COMMENTS: FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 10, Block 1, Kimberley Manor S/D November 3, 1994 Dave Kretsinger Pt Peat and loam fill Pt ML Gray gravelly silt Dense, cohesive, damp SM Brown silty sand NIL Gray sandy silt Dense, cohesive Softer than above SP Black sand w. septage B.H. SLOPE ~,~ .~. ,... ·..~ ~ ~ ~ **************************** ~* THEODOR~ F ~'~OORE ~ ' ...... SITE P~N HOUSE ~X ~,,> T.H. T.H. ~% '~ \ PIT Depth to Groundwater Date 10.75' 11/3/94 Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) PERCOLATION RATE (minutes/~nch) PERC HOLE DIAMETER TEST RUN BE'rVVEEN FT AND FT Soils in this test hole are not suitable for construction of an on-site soil absorption system. No monitor tube installed, PERFORMED BY FLATrOPTECHNIOALSERVICES. [. ~,~',.~.~ ,~ ~ ADCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATEi CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: November 9, 1994 ITESTHOLE# 2 LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (teet) COMMENTS: FLATrOP TECHNICAL SERVICES _.-~ OF A-~i 14530 ECHO ST. ~ ~?.-' ,~ *,, .~.~, .,,% %° /,~, %'m,~ .~-~ i ANCHORAGE, ALASKA 99516 ~2," g9~J ~; SOILS LOG -- PERCOLATION TEST Lotl0, Blockl, Kimberley Manor S/D ~) · T~'IEO00~ r ~,o~" ~" ~'~, % C~ - 3589 November3, 1994 ,~/,~_.~, ,,,,..~, ~%~ Dave Kretsinger "q ~,~,~'. SLOPE SITE PLAN ?t ~ Gray/brown ~rave]ly silt Dense, cohesive, hard di~sin8 Many cobbies SM Gray silty sand #1 Depth to Groundwater Date No ~roundwater 11/3794 ML Gray silt Dense, cohesive Scattered lenses of SM < 0.5' thick B.H. Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT Soils in thi~ ta.~t hole are not suitable for consa'uction of an on-site soil absorption system. No monitor tube in~talled, PERFORMED BY FLATTOP TECHNICAL SERVICES. I.. AOOORDANOE WITH ALL 8TATE AND MUNIOIPAL GUIDELINES IN EFFEOT ON THIS DATE. CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: November 9, 1994 ITESTHOLE# 3 J LEGAL DESCRIPTION: · DATE PERFORMED: PERFORMED FOR: (feet) 1- COMMENTS: FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 10, Block I, Kimberley Manor S/D November 3, 1994 Dave Kretsinger SLOPE Pt ML Gray gravelly silt Very hard and dense No sand lenses Water seep at 5.5' #1 B.H. Depth to Groundwater Date Seep at 5.5' 11/3/94 Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT Soils in this test hole are not suitable for con~tn]ction of an on-site ,~oil absom, fion system. No monitor tube installed, Water seep at 5.5' did not perc into ML at bottom of test hole. PERFORMED BY FLATTOP TECHNICAL SERVICES. I. ~-'_J,__ ~ ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: November 9, 1994 TEST HOLE # 4 LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (i'eet) COMMENTS: ~.0 ~ .~., FLA'I-rOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, A~SKA 99516 ~.~.~..,......,,,...,~.;~ SO LS.. PERCOLAT O TEST November 3, 1994 .~ Daw ~e~in~er ~~ ,, SLOPE SITE P~N Gray~ro~ ~mvc~y Dens~, cohesNo, ve~ Scatter~ lenses of SM b~low 9' Depth to Groundwater Date No ~roundwater 11/3/94 B.H. ' · · - : : : Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT Soils in this test hole are not suitable for construction of an on-site soil absorption system. No monitor tube installed, PERFORMED BY FLATTOP TECHNICALSERVICES. I ~~,,~ ACCORDANCE WITH AL.L STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: November 9, 1994 Flattop Technkal Servkes 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 10, Block 1, Kimberly Manor S/D 7640 Upper DeArmoun Road Holding tank installation Specifications 1.0 General: 1.1 The scope of the project consists of abandonment of an existing 750 gallon septic tank and seepage pit and installation of a new 4000 gallon holding tank with high level alarm system. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All c. onstmction procedures and material specifications shall conform with Municipal and State reqmrements. All separation distances shah be in confm~ance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2/0 Holding Tank: 2.1 The existing septic tank and seepage pit must be properly abandoned by thoroughly pumping, removing the top and backfilling with soil. 2.2 The new 4000 gallon holding tank shall be Municipally approved and shall be set level on undisturbed soil. The tank shall be designed by the manufacturer for burial up to 6 feet below ground level. 2.3 All pipe connections to the tank shall be equipped with waterProof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot. A double cleanout shall be installed at the point where the new waste line is connected into the existing waste line coming from the residence. 2.4 The holding tank shall be equipped with a low voltage, high level alarm which triggers an approved visible and audible almrn mounted inside the residence. The float shall be positioned tO trigger the alarm when the fluid depth in the tank is 57" above the bottom of the tank, leaving approximately 600 gallons of capacity remaining in the tank. . 3.0 Inspections: 3.1 A total of 3 engineering inspections will be required during the course of the project: (1) initial · stakeout with'the contractor to establish the location of the tank and to discuss the plans, specifications and construction procedures, (2) after the tank has been set in the ground and the piping connected, but prior to backfill, and (3) after the rough backfill is complete. 3.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. ~1~'~ ~ J ~ R ANCHORAGE AREA BORO~'~H HEALTH DEPARTMENT 327 EAGLE fir. ANCHORAGE, A[ASI~. 99501 279-2511 N.o INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: MAILING ADDRESS -~'.21-~.~,~, ~/.-~X ~.~'~'~ ~ DISTANCE FROM WELL ,J¢'~' / MATERIAL ,~./~'-~.~.~-~/ NUMBER OF COMPARTMENTS / )"~-,'~(-~' -,Y~4..-~ ,~.,,~,~a~, ,__.,.~.- LIQUID LIQUID CAPACITY ,~,~d-~) GALLONS· INSIDE LENGTH / INST'DE WIDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT.. NUMBER OF PITS / OUTSIDE DIAMETER OR WIDTH //~ · . . DEPTH LINING MATER~AL ~'4-.¢~-~-~/~ ..~.~'/J~-~-.~.~ . DISTANCE FROM WELt BUILDING FOUNDATION NEAREST LOT LINE/~.'~/~' ~'-" TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) '~'"~'~' SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL //~0, FOU ATIO~N~ NUMBER OF LINES ~ DIST ETNDATION DEPT~: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE /~'~TOTAL LENGTH NEA RES~JINE. /,~DF LINES EACH LINE. ~.J~ENCH WIDTH ~~E IN. ABOVE TILE WELL: LOT LINE ~ DISTANCE FROM TYPE ,?.,~//-,.:~/~ DEPTH ~ , , BUILDING FOUNDATION. NEAREST ~ SEPTIC ~-_-~ .~ SEEPAGE ./F_2 z-~z~ , SEWER LINE , TANK ~ ~ , SYSTEM WATER SAMPLE ..,ff/~ , NEAREST OTHER , CESSPOOL ~' SOURCES4--~ DISTANCES: DIAGRAM OF SYSTEM DATE ' ~z ' '¢ ~' ~ " ' z/ APPROVED HEALTH AUTHORIi'¥ GREATE?i. ANCHORAGE AREA ~ OROUGH 327 Eagle St. Anchorage, Alaska 99501 279-2511 SEWAGE NAME OF APPLICANT C~ RESIDENCE ADDRESS LEGAL DESCRIPTION APPLICATION TO INSTALL: SEPTIC TANK TO SERVE THE FOLLOWING FACILITY FINANCED THROUGH PERCOLATION TEST RESULTS D s ,os^. sYsTE, - & MAILING ADDRESS ~ 'S?~'-~ PHONE NO. LOCATION OF INSTALLATION , DRAIN FIELD , OTHER. SEEPAGE PIT ~;~,~ TO BE INSTALLED BY. ANTICIPATED DATE OF COMPLETION. BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS AS DESCRIBED BELOW. SIZE OF~UNIT~O BE SERVEB /c~ "-~'~i~ SEPTIC TANK SIZE ,'~-Q'~'"'~ TYPE e~ ~%~oeb SEEPAGE AREA.. TYPE ~:)' ~ ~v'~ LLTH AUTHORITY ENSED DESIGNER I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordin~Fe No. 28-68 and that the above described system is in accordance with said code. t~,~r-- ~,_)~_ ~x.~ N_~ {*Q~)/(~)[~"l ._~'~-(~ ! C~- ~"TE APPLICANTS SIGNATURE 'EATER ANCHORAGE AREA.BOROUGH HEALTH DEPARTMENT 327 EAGLE STREET ANCHORAGE, ALASKA 99501 CASE # u t Performed For Arthur Andries Date Performed__ 8/28/70 Legal Descrip~~~n This Form Reports a: So~is Log xx Depth Feet Soil Characteristics Location Sketch gray clayey silt (CL) gray silty sand with few gravel (SM) 8~ I gray fine to coarse sand 10 ~_ (ow) · If Yes, A+ <~a~ Depth 11,.~, feet__ Gz'c-s~_~ Time Net Time Depth To H20 Net D~ I PPop%ed !nstal~Seepage Pit D~ain Field Depth Of' Inlet Depth To BoEtom Of Pit Or '~ "" COMMENTS: ___~_m~ea~ar~ ~age ~equired is 167 squ§re fe~t per bedroom T~$~ Performed By: R. E. Carli.._sle These recommendations are computed from ' ~ visual observation and based on the uni- fied classification system. Data Certified By: National Testin~ Service Inc. Da~e: Parcel I.D. # 1. GENERAL INFORMATION Complete legal description ' MUNICIPALITY OFANCHORAGE ' ' DEPARTMENT OF HEALTH & HUMAN SERVICES_ Division of Environmental. SerVices On-Site Se~ ces Sect on ...... P.O. Box 196650 Anchorage'A aska 99519-6650 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Location (site address or directions) Property owner D~ u;,~(_ /~r-e_ ~n~_,- Day phone Mailing address Lending agency . . Day phone Mailing address ~- ~, ~o~ I~ ~' Agent 51.~. Address Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: ~ 3. TYPE OF WATER SUPPLY: m Individual well NOTE: Community well Public water .: If community well system, provide written confirmation from State lng to the legality and status of system. . . TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verifythat based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system s in compliance with ail Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm fCl~(-~? 7'~c/~ ~¢~[ ~er~;c~' Phone Address l~1~30 ~o ~/) ~o~; A~ Engineer's signature ~~ ~ '~ DHHS SIGNATURE /~ .. Approved for Disapproved. Conditional approval for bedrooms. STA /tP bedrooms, with the following stipulations: · -Additional Comments ' ~ "/ "' Date / By. The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements, Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions i.n the professional engineer's work. 72-O25 (Rev. 1/91) Back MOA #21 Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: I-c,{" (d,'/ ~3 ]lc ~) I~,,~¢,'-Iy Parcel I.D. A. Well Data Well type i> fi ua/-~ If A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) hi Date completed l? 7~2 Driller Total depth ~_ o,5-' Cased to Sanitary seal (Y/N) FROM WELL LOG Date of test Static water level Well flow Pump level1 SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot -Z? ' Absorption field on lot /',/,,,~-, Public sewer main Sewer service line ~n k- Casing height Wires properly protected (Y/N) AT INSPECTION ~-/7 1~'7~ .g.p.m. ; On adjacent lots '~. ~oo ' g.p.m. <~ ; On adjacent lots Public sewer manhole/cleanout /,/. ,4. Petroleum tank Non ~ WATER SAMPLE RESULTS: Coliform ~ col / ~ 0 0 Date of sample: Nitrate Collected by: Other bacteria hi B. SEPTIC/HOLDING TANK DATA Date installed I ~-/' 7 / ~ ¢/ Cleanouts (Y/N) Y High water alarm (Y/N) ¥' Date of pumping bL /~. Tank size ~ 000 ~ ~ / Compartments Foundation cleanout (Y/N) 'T' Depression (Y/N) Alarm tested (Y/N) ~' n ,~<~) Pumper N,/J-. N SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot -7~ To property line Sudace water/drainage On adjacent lots '~ 76-' Foundation ?--~ ' Absorption field N,/~. Water main/service line '~ z-,.5''/ lO0~ 72-026(3/93)* Front CONTINUED ON BACK PAGE Co LIFT STATION /x(, 6. Date installed Size in gallons Vent (Y/N) High water alarm level Meets MOA electrical codes (Y/N) "Pump on" level at SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot D, ABSORPTION FIELD DATA Date installed Length Total absorption area Date of adequacy test Width Manufacturer Manhole/Access (Y/N) "Pump off" Level at Cycles tested On adjacent lots 8oil rating (GPD/FF) Gravel thickness Cleanout present (Y/N) Results (pass/fail) Water level in absorption field before test Peroxide treatment (past 12 months) (Y/N) SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot To building foundation On adjacent lots Surface water Curtain drain E, ENGINEER'S CERTIFICATION Surface water System type Total depth HAA Fee $ Date of Payment Receipt Number I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on.J,.~ate of this inspection. . ~ ~,'~r;?:]i, On adjacent lots Properly line To existing or abandoned system on lot Cutbank Water main/service line Bedrooms Waiver Fee $ Date of Payment Receipt Number Driveway, parking/vehicle storage area Depression over field (Y/N) for After test If yes, give date GREATER ANCHORAGE AREA BOROUGH' DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 REQUEST FOR INDIVIDUAL SEWER DATE RECEIVED:. /~/'///~/~_- APPROVAL OF AND WATER FACILITIES FOR APPROVAL REQUESTED BY: m~:/~//~- ~-~ J~/~/~-~:/--' ADDRESS: ~'/~ ~~ ~://~ ~~:~/ ~:~ PHONE: ~~ ~:~ WELL DATA: A. TYPE B. DEPTH PROPERTY OWNER: .::/-//~-~ PHONE TYPE FACILITY TO BE INSPECTED:://~:~~/~STREET: NUMBER OF BEDROOMS: ~ " / D. CONSTRUCT*O, E. BACTERIAL ANA,YS*S SEWAGE DISPOSAL SYSTEM: SEPTIC TANK 1 . SIZE 2. AGE 3. ' 4. (IF HOMEMADE, SHOW DIAGRAM ON BACK) APPROVAL REQUES~,-.~OR SEWER & WATER FACILIIIL~, PAGE TWO o SEEPAGE PIT - / 2 L I N I N G~/~-~ ~ ~/~/'~:~~':/ DISPOSAL FIELD 1. NUMBER OF LINES 2. TOTAL LENGTH_ REQUIRED MEASUREMENTS A. WELL TO SEPTIC TANK B. WELL TO SEEPAGE PIT C. WELL TO SEWER LINE O. WELL TO PROPERTY LINE___,/__~ /~ E. WELL TO OTHER POSSIBLE CONTAMINATION F. FOUNDATION TO SEPTIC TANK G. FOUNDATION TO SEEPAGE PIT_ H. SEEPAGE PIT TO PROPERTY LINE_~ -~_~.~ ~) "" DISAPPROVED: APPROVED: ' DATE :~/,7~,/~,~'. DATE: APPROVAL VALID FOR ONE YEAR FROM DATE SIGNED. GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALIT