HomeMy WebLinkAboutKIMPTON LT 2Ki'Ornpton Lot 2 #051-072-65 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone. (907) 343-7904 Fax: (907) 343-7997 http://www.muni,orglonsite On -Site Wastewater Disposal System Permit Permit Number: OSP201140 Work Type: SepticTank Upgrade Tax Code Number: 05107265000 Site Legal Address: KIMPTON LT 2 G:1458 Site Mailing Address: 22301 KIMPTON CIR, Chugiak Owner: MANTYLA THAD R & LEISEL A Design Engineer: NORTH RIM ENGINEERING This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date Lot Size in Sq Ft Total Bedrooms: nt 1 f 1)c•hartmcnt 6/5/2020 6/5/2021 59940 ❑ Private Well ❑ Water Storage 3 All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: If deck is replaced, deck supports shall maintain required separations to the septic tank per AMC 15.6520513,1A. Received By. Issued By: r�Z 6/5/20 Date: / Date: V a�w� o MUNICIPALITY OF ANCHORAGE Development Services Department Phone. 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-072-65 Property owner(s) MANTYLA THAD Mailing address 22301 Kempton Cir Site address same Day phone 351-8219 Legal description (Sub'd., Block & Lot) KIMPTON LT 2 Legal description (Township, Range & Section) Lot Size 59940 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (xN all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) 0 (w/wo ADU) Septic Tank 0 Upgrade (D) El Holding Tank ❑ Renewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees Date of Payment: X25 168.75 s 8 ad2 o Receipt Number: U7 3 '/ 5 1) Permit No. 0 SP.?011 NO Waiver Fees: Date of Payment: Receipt Number: Waiver No. G1Development Services\Building Safety\On Site Water and WastewaterTormsUient FormsTermit Application.doc SteveEng.com Steve Eng, PE, PH 907-694-7028 SteveEngPE@gmail.com Date: 5/26/20 Number of Pages: To: MOA On-Site Services Subject: Kimpton Lot 2 Septic Tank Failure The subject septic tank has failed- a new tank will replace the old one. The existing seepage bed appears to be working OK- it has been functioning for many years. Please issue a permit so the tank can be replaced. The existing seepage bed will remain. Please review as soon as possible. This is a large lot with no nearby neighbor conflicts. If there is need for additional information or clarification please give me a call. Thanks-Steve Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201140, Rebecca Carroll, 06/05/20 Kimpton Lot 2 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: The current septic tank has failed- the seepage bed still functions. This lot is over an acre. No adverse impacts are expected from tank replacement. The easements are depicted on the lot. The slope is indicated in the area of the septic system. No conflicts to neighbor properties. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations.  New 2- compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet.  5 minimum between the tank and trench. 5 to property lines & 10 to house.  4 of cover or insulation is required for tank; an equivalent of 1 insulation for 1 foot soil cover. Tank & solid pipe must be set on well compacted, stable soil.  No large rocks for tank bedding. Plastic/fiberglass tanks require special bedding per MOA- sand or pea gravel.  4 diameter cleanouts with airtight caps are required 1 to 4 from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10 from the tank positioned to provide cleanout access towards the tank and towards the absorption field.  All cleanouts must extend to at least ground level.  In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.  Insulation must be placed over any pipe installed under driveways or parking areas.  Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661,  Sewer Service Line is minimum 2% slope.  Septic Tank to be pumped every two years or when required.  Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201140, Rebecca Carroll, 06/05/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201140, Rebecca Carroll, 06/05/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201140, Rebecca Carroll, 06/05/20 W N 0 00 01 CD N Z W O J H U 0_ CLQ U Y U J N 00.06'15' W 142.00' aq \� o 1.0 C,6 n u o- < \ of J 10 Lq L1 Q / co r r M �K• Z / li7 uI/� �O HI c cri W i J W Q Q ... LO CY) ISI / y 20' Drainage Esnt N 00'06'13' W r O U O C1, _ Q U OV U v 192.76'`a� cc v a vOi O '^ tU.. � •U U s oQ QA a ou y c: on 4° E A x ° a V..>'N to E � .fl n lu °~ s � 'cm t�Q axi�Q.vv W Y m o W ct _ m Urn U (� Q C N Q �J J m m 0 0 04 0 04U .0 m F- a Qo U- CL 0 \k U / ua U 00 UO. I B N G � y .. cz 0i W 3 3 0 ?7 La Ln CCS .5.: '4- O a (� g O �.. A a rn ri U � cn o (U cn00 «5 r_-> = t� o Z —1 20' Drainage Esnt N 00'06'13' W r O U O C1, _ Q U OV U v 192.76'`a� cc v a vOi O '^ tU.. � •U U s oQ QA a ou y c: on 4° E A x ° a V..>'N to E � .fl n lu °~ s � 'cm t�Q axi�Q.vv W Y m o W ct _ m Urn U (� Q C N Q �J J m m 0 0 04 0 04U .0 m F- a Qo U- CL 0 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org Septic System Owner-installer Agreement The On-site Water and Wastewater Section (On-site) may issue an approval for a homeowner to perform work on an on-site wastewater disposal system to serve that individual's owner- occupied, single-family or duplex home if the homeowner meets and agrees to the following requirements: 1. The property owner and excavation equipment operator may perform work on no more than one owner-installation project in a 12-month period. 2. Owner’s projected active involvement with the installation: _______________________________________________________________________ _______________________________________________________________________ 3. The name of the excavation equipment operator: ________________________________ 4. I agree that there will be no monetary compensation for installation services rendered. 5. The name of the inspecting engineer: _________________________________________ 6. I agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.070. c. Advance notice given to the On-site Water & Wastewater Section for all required municipal inspections (AMC 15.65.070A). 7. I agree to have the project-specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. 8. I agree that if the system is an advanced wastewater treatment system (AWWTS), I will obtain additional installation instructions and approval from the equipment distributor. As owner of (legal description) ________________________________________________ I agree that the information above is true and accurate. Owner’s printed name: _________________________ Owner’s signature: _________________________ Date: ________________ DocuSign Envelope ID: C06C346A-DBB2-4299-AA95-17B9231C38A3 Thad Mantyla Thad Mantyla Steve Eng 6/6/2020 100 % involvement in tank replacement. Equipment operator / Laborer JAN 10;014 -=-:--Inspection Report_1-1-12.dbmC' Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: SW040460 PID Number: 051-072-65 ❑✓ New ❑ Upgrade Name: Thad Mantyla ABSORPTION FIELD ❑ Deep Trench El Shallow Trench ❑✓ Bed El Mound Address 22301 Kimpton Circle Chugiak, AK 99567 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 351-8219 1 3 -3 GPD/SF +4.8 Ft, LEGAL DESCRIPTION Depth to pipe invert from original grade +1.6 Ft. Gravel depth beneath pipe .6 Ft. Subdivision Block Lot Kimpton 2 Fill added above original grade _ 4-5 Ft, Gravel length 50 Ft. Township Range Section Gravel width 30Ft. Beds: Number of Lines 5 Distance between lines 1 5Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 1,500 Ft' Ft. Well >100' >100' N/A N/A >25, TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1 1,000GaI. Surface Water >100' >100' N/A N/A Material Steel Number of compartments Two Lot Line >5' >10' NIA N/A NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. - Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL Housetotank D3034 drainfield Tank to D3034 Owner Installed Drainfeld HDPE CO/MT D3034 InspectorTLKBENCHMARK (Assumed elevation) 100.Oft Inspection ,i 1 12/8/04 1219104 Location and description dates: 2°a 3" 12/10/04 4'" Finished Floor COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL ::®®�,iji'i, .°• 9S Conditional Approval: Date ' �® .... 0e - *.MICHAEL E. ANDERSON •° ¢e *4 r CE -4381 �a Approved Date._-) ABpFESS16NA 0i�Q4 '® 100 -=-:--Inspection Report_1-1-12.dbmC' n D- r a 20' Drainage Easement ------------------------------------� I I I I I rnoata<' � I o I n I I I I N m I I I T I A I 0OD I DN V I 3 N N®N > I 2 o bd s © o CD C 0 �^ H I N m 3 \ I I \ I n I m I I \ s I I m I I ` I \� I V I I M no yV M N O V O �1 z � I O x a C OHO <p l7 � o Z J I Z O I� A C) r M 3 O T - m -.. Z c v m VA 7 O N O N m ei 14 m a 0 CD p 0 Qm o Dom: o: M m_ p Zi cn2 mm; D�c N N r �pc 1pma >c Ln D �m WZ 0 A Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW040460 PID No. 051-072-65 y /—97.8 � UU 1,000 Gallon Septic Tank N U H N PROFILE AS -BUILT - No Scale �_ W16\jm. MICHAEL E. ANDERSON DEPTH (feet) 1 - 2 3 4 - 5 - 6- 7- 8 - 9 - MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 2, Kimpton Subdivision PERFORMED FOR: Thad Mantyla DATE: 11/28/04 PROJECT No.: PARCEL ID#: TECHNICIAN: T. Kinbrough. TEST HOLE A ✓ IF YES @ WHA I 1 DEPTH OF WATER AFTER MO DATE OF MO 13 14 15 16 17 18 19 SLOPE 49thc. MICHAEL E. ANDERSON SITE PLAN U See Site Plan x T DEPTH? O MTGRING: P NITORING: E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:10 2.50" 2 11:40 30 3.06° .56" 3 11:41 2.75" 4 12:11 30 3.25" .50" 5 12:12 2.50" 6 12:42 30 3.00" .50" PERCOLATION RATE: 60 Wm/INCH) PERC. HOLE DIA—.6---(INCHES) TEST RUN BETWEEN: 2 FT. and 3 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERCOLATION TEST TO VERIFY SOIL ABSORPTION. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 1/10/14 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 2, Kimpton Subdivislon PERFORMED FOR: Thad Manty(a DATE: 11/28/04 PROJECT No.: PARCEL ID#: TECHNICIAN: T. Kimbrough DEPTH TEST HOLE B (fee[) 1 2 3 4 5 6 7 8 9 11 12 14 15 16 17 18 19 SLOPE WAS GROUND WATER ENCOUNTERED? IF YES Qa DEPTH OF WATER AFTER MO DATE OF MO �••'P�. OF A( ♦ 49th' �r�C;d?- M]CMAEL E. ANDERSON 4 f'•., NO. CE -4381 SITE PLAN t See Site Plan WHAT DEPTH? O NITORNG: 0 - NITORING: r L. [H[READING GROSS TIME NET TIME WATER TNE DROP (MINUTES) (MINUTES) (INCHES)HES) TEST HOLE PRESOAKED PRIOR TO TESTING: 11/28 1 11:22 1.25" 2 11:52 30 1.75" .5011 3 11:53 1.38" 4 12:23 30 1.88" .5011 5 12:24 1.5011 6 12:54 30 2.0011 .50" PERCOLATION RATE: 60 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 2 FT. and 3 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERCOLATION TEST TO VERIFY SOIL ABSORPTION TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE- 1/10/14 PERCOLATION RATE: 60 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 2 FT. and 3 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERCOLATION TEST TO VERIFY SOIL ABSORPTION TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE- 1/10/14 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (F May 5, 2013 Thad Mantyla 22301 Kimpton Circle Chugiak, AK 99567 Subject: Lot 2, Kimpton Subdivision Well and Septic System Permit No. SW040460 Dear Thad: We originally designed and secured a construction permit from the City for the well and septic system on your lot in October of 2004. The system was finally constructed in December of 2004. The work was inspected by Tim Kimbrough, an engineering technician under my supervision operating as Ve Tech Technical Services. Unfortunately Mr. Kimbrough has passed away along with his documentation records. We are unable to complete the final certified as built of the septic system without a surveyor as built. The City has contacted us several times to finalize this as built, but we can't verify the location of the property lines, proximity of the septic system to the house or the separation distance from the well. We will complete the as built once we receive the surveyor certified as built from you. Please let me know if you have any questions. Sincerely, Michael E. Anderson, P.E. xc: Municipality of Anchorage On Site Water and Wastewater Program ff4 r Mayor Mark Begich DZunicipality of Anchorage P.O. N)x 19WO • Anchomgc, Alaska M519 G50 • Tc1q)honc (1)n7) 3M3-&Vl • Fm (007) 34.4-f."()0 4700 Bmgaa Stwcl • :Mnchomgc, AlacM <,i9507 September 13, 2005 Thad Mantyla 7200 Biglerville Circle Anchorage, AK 99507-2885 mimmani.org Building Safety Dic-ision Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW040460 Legal Description: Kimpton Lot 2 .n.I Dear Mr. Mantyla: An On -Site Water/Wastewater Permit, number SW040460, issued by this office for a single-family system, will expire on October 27, 2005. The permit is valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $115.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, t)d;W-.J0' 11_f� Daniel J. Roth Program Manager On -Site Water and Wastewater Program Enc: Copy of permit Community, Security, Prosperity MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW040460 Legal Description: KIMPTON LT 2' Design Engineer: 0014 Anderson Engineering Owner Name: THAD MANTYLA Owner Address: 22301 KIMPTON CIRCLE CHUGIAK , AK 99567-0251 uIbIoil raoPCV'N Date Issued: Oct 27, 2004 Expiration Date: Oct 27, 2005 Parcel ID: 051-072-65 Site Address: Lot Size: 59940 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 Thi ermit is for the construction of: Disposal Field QrSeptic Tank EJ Holding Tank [] Privy ERIPrivate Well ❑ Water Storage All construction must be in accordance with: I. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and dosed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. A PERC TEST SHALL BE DONE PRIOR TO CONSTRUCTION SO THE DESIGN OF THE SUBSURFACE DISPOSAL FIELD IS NOT OUTSIDE 30 FOOT RADIUS OF THE TEST SITE. THE ENGINEER SHALL OBTAIN SUFFICIENT PERCOLATION TESTS TO ENSURE THE REQUIRED SUBSURFACE DIPOSAL AREA EXISTS. t2'ale{_ Sfa �EI...o frcon t":kE ANcfnso-) G?reo rt/?of.., Foe oEa15.4 cA"'r. rT-ra w,,, GE SV& ^ 7o w, vAN R. o.k.lot .7QI v10,E acv As 1-" AS-rple"C is 20 oG M•u.w, APO+VVCO SANO Fac TLS M:k.E ANOErlfid fAip /-%f $-At 70m,J 7-0 S#jo,. gy W/ rif-f.07j,r�Tr uEw TGST 1�os E� D�Sca�/s1oN Now c0VSrQyCTroN WAS, Nccj�rl'VNEb W/o pKitn:.) &.,ick- Nor o^(daffu— of 96171 WV0 /11c rV'lES OF dso DO -4,47 Z0^rrnuo.rlov, �7ff�l Received By: Issued By: Date:d S Date:0 Z oc/ Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 995196650 www.ci.enchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-07265 Permit Number SW Property owner(s) Thad Mantvla Day phone 3518219 Mailing address (1) 7200 Bialerviile Circle Anchorage, AK 99507 Mailing address (2)a' ?01 Kimaton Circle ip Code Legal description (Lot, Block & Sub'd.) Lot 2, Kimoton Subdivision Legal description (Section, Township & Range) Lot Size *q q 46) Acreoe> THIS APPLICATION IS FOR: Number of Bedrooms Three (3) Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. 1 further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. E (Signature of property owner or authorized agent) Permit Fees: Waiver Fees: Date of Payment 1451bC1 Date of Payment Receipt Number J ��� Receipt Number. (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 MEMO DATE: 11/30/2004 TO: Joe Goodall WITH: MoA/OnSite Water and Wastewater FROM: Mike Anderson SUBJECT: Lot 2, Kimpton Subdivision Well and Septic System Permit No. SW040460 Revised Septic System Design Attached is a new Site Plan for Lot 2, Kimpton Subdivision. The absorption system has been changed to a shallow bed due to the proximity of groundwater noted during the past month. We are proposing placement of a 30' by 50' absorption bed with the bottom of the bed approximately 1' above the surface. The distribution piping will be placed at 1.5' above the surface. Organics will be removed and replaced with coarse sand to the required elevation. A cross sectional view of the bed is also enclosed for your review. Please let me know if you have any questions. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522.6779 FAX October 23, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Kimpton Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Kimpton Subdivision intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the new home. No conflicts exist with adjacent septic systems or wells and the proposed septic system and well on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The proposed well is also shown. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated silty sand and gravel in the area of the absorption trenches. The accepting soils were tested and found to have a percolation rate of 20 to 60 minutes per inch. The system is designed for the slower percolation rate. No groundwater was found in the Test Hole No. 2 during placement, but was found at 8.5' below the surface on October 15, 2004. Our design includes the placement of a new 1,000 -gallon septic tank along with 2 - 58' long by 5' wide by 3' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trench will be 4' below the surface. The distribution pipe will be 1' below the surface. A flow splitter valve will be placed to assure even flow to each trench. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from east to west as shown on the Site Plan. The absorption trenches will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The Lot 2, Kimpton Subdivision October 23, 2004 Page Two new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Jn Michael E. Anderson, P.E. Attachments y� *N G 49th z EEKEM 21 W r✓QO \OP 63 a��%rr ., 5E ,SA Na 1js7i EMn 11981 u11�•�E `�/'�D e UVV 8 —• = � 11 X 1� O 9 N 10 14975 "^^a• 15719 11197 S89158102'E 8.00 87472 _ m Ev. e O L Kimpton Circle 8 VACANT $ 3 4 g .• �..� ........ + 49h f^1 •••. •i �1 Ne91574 ��...•J•••i• 02178 ..IC E R 709.00 11]8 �I N�CRAEI E. ANDERSON S No. CE4\e1 r(r�2i X44 t... -T1-..... t 6 s AREA MAP SCALE 1• • 100' Existing Ground LOT 2, KIMPTON SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 3 Bedroom Home Shallow Bed System Perc. Rate: 31.60 MinAnch 1.000 Gallon Septic Tank Application Rate: .3 GPD/SF 2' Coarse Sand 3 Bedrooms X 150 GPD/.3 GPD/SF = 1,500 SF Absorption Area 1,500 SF/30 SF (Width) = 50 LF Bed Length THEREFORE: Construct a 50' Long (Avg.) x 30' Wide Shallow Bed as Shown Below. Place Distribution Piping at 1.5' Above Original Ground Surface. Remove Organics and Place 2' of Coarse Sand to Provide 4' Separation From Groundwater (Minimum). Place Insulation and 2' of Cover Over Bed or Mound Over Bed Minimum of X. Place 4' of Fill Over Septic Tank. Natural Backfill 2' Insulation 8 2' Cover (Min.) O O O O O Drainfield Rods 4" Coarse Sand (See Specification) In Situ GP Soil 3' 6' 6 6' 6' 3' 4 711 I ZL0 TYPICAL BED SECTION (NO SCALE) NOTE: Grade Area Surrounding Bed to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. i Minimum 100' Separation From Wells In the Area. It Minimum 100' Separation From Surface Water or Streams. . Minimum 10' Separation From Water Service Line. Existing MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2. KIMPTON S/D PERFORMED FOR: THAD MAN A DATE: 9/9/04 PROJECT No•M0482 PARCEL I0,4•051 072 65 TECHNICIAN: T. L. KIMBROUGH HI TEST HOLE # 1 Type of Test: ® Percolation ORGANICS/OB/OG MOIST SILTY—SANDS MEDIUM COMPACTION DAMP SILTY—SANDY—GRAVELS WELL COMPACTED WAS GROUND WATER ENCOUNTERED IF YES Q WHAT DEP711 DEFTII OF WATER AFTER MONITORING: DATE OF MONITORING: BOH/SEEPING WATER 0% Yes 14' 9' 10/15/04 49th C AMICRSM SITE PAN a THo ob TH2 T 0 TH0c THH1 TH d o 12 SFE FUTURF ASM111J <5% I DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATERF (INCHES) NET DROP (INCHES) 9/9/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 12:45 1 of 2 13:15 30 17/16" 9/16" 3 13:15 17/16" RECHARGE 4 13:45 30 11/8" 1/2" 5 13:45 1 1/8" RECHARGE 6 14:15 30 27/819 1/2" PERCOLATION RATE60(MIN/INCII) PERC. HOLE DIA• 6 fINCI{ES) TEST RUN BETWEEN: 6 FT. and 7 FT. COMMENTS: No Impetmeables Encountered:** Denotes monitoring on this date of existing Test holes a, b, c, & d: TH a Dry-, TH b Water (a. 9 R• T1 c Dry: III d Dry; TEST PERFORMED BY VETECII ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: Io — Zt — D ✓ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2. KIMPTON S/D PERFORMED FOR: THAD MANTYIA DATE: 10/01/2004 PROJECT No -•M0482 PARCEL ID, #•051 072 65 TECHNICIAN: T. L. KIMBROUGH Drrnt TEST HOLE # 2 Md) I —r//A ORGANICS/o6/OG 13 14 BOH 15 16 17 18 19 COMMENTS: Test Hole Presoaked Priot to Test. No 8.5' 10/15/04 49th L MDERSW SITE PAN o oa THb TH2 T O THc THH1 o To d s SFF FUTURE ASI9UII.T <5% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH of WATER (INCHES) NET DROP (INCHES 10/04/04 TEST HOLE PRESOAKED PRIOR TO TESTING: MOIST 1 11:40 12.0" MEDIUMSILTY-SANDS. r' i'• i� 30 10.625" 1.375" 3 • +M �M �1 4M, �1• �/, 10.375" 1.625" j� 4� ,h �� • • ,► RECIIARGE �► WELL COMPACTED 6 13:10 30 10.5" GM 1 .4 4; i WAS GROUNDWATER ENCOUNTERED �� h y� M 1IFYES@WILATDEVni ;► ;1, �/;DEFvn I OF WATER AFTER MONITORING: DATE OF MONITORING: 13 14 BOH 15 16 17 18 19 COMMENTS: Test Hole Presoaked Priot to Test. No 8.5' 10/15/04 49th L MDERSW SITE PAN o oa THb TH2 T O THc THH1 o To d s SFF FUTURE ASI9UII.T <5% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH of WATER (INCHES) NET DROP (INCHES 10/04/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:40 12.0" CHARGE 2 12:10 30 10.625" 1.375" 3 12:10 12.0" RECHARGE 4 12:40 30 10.375" 1.625" 5 12:40 12.0" RECIIARGE 6 13:10 30 10.5" 1.5" PERCOLATION RATE 20 (MM/INCH) PERC. HOLE DIA. (INCHES) TEST RUN BETWEEN, 4 FT. and_,J_FT. TEST PERFORMED BY VETECII ENGINEERING TECFFNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: /V — Zr_0 $0 u sUi LS LOG MUNICIPALITY OF ANCHORAGE t� • �u DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION % PERCOLATION \, 825 L. Street, Anchorage, Alaska 99501 264-4720 TEST SOILS LOG — PERCOLATION TEST PERFORMED FOR: J .����� y LI DATE PERFORM ED:20 /J/TI Cf9 2' LEGAL DESCRIPTION: !V /t� % �� / "I DEPTH 1 2 y j� S/L.7y 3 4c 4 5 p 6 9 cze i 10 11 12 13- 14 COMMENTS Date Gross Time 15 Depth to Net Water r)rnn t . 20 f11n /� Z'31) 16 sP G /L 17 18— MS- &e1;aN A. SI., ! C e No. 1!•57-E 19- 9 o ZJ /j 20— 20 COMMENTS WAS GROUND WATER ' < S ENCOUNTERED? / L O P IF YES, AT WHAT E DEPTH? Reading •: ;-1 Date Gross Time Net Time Depth to Net Water r)rnn 20 f11n /� Z'31) sP G /L o ZJ /j PERCOLATION RATE : //_; (minutes/inch) TEST -RUN BETWEEN FT AND J FT PERFORMED BY: 5 J�j1/C-!"N.� l'fZ//�'L CERTIFIED B 72-008 (6/79) DATE ONSITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, KIMPTON SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of two new 58' long X 5' wide X 3' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trench will be placed at 1' below the existing ground surface. Total depth of the trench will be 4' below the existing ground surface. A Zabel Flow Splitter Valve must be placed to insure even flow to each trench. A separation distance of 100' from any well and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 'Lot 2; Kimpton October 23, 2004 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 1; Kimpton October 23, 2004 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered In the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system.