Loading...
HomeMy WebLinkAboutKINCAID ACRES LT 2EKincaid Acres Lot 2E 011421m96 EXPIRED PERMIT, NO SYSTEM INSTALLED PER ENGINEER OF. RECORD? MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jul 26, 2006 Expiration Date: Jul 26, 2007 Permit Number: SW060227 Parcel ID: 011-121-96 Legal Description: KINCAID ACRES LT 2E Design Engineer: 0007 SPURKLAND ENGINEERING Site Address: Owner Name: JEFF HANSEN Lot Size: 42071 SO. FT. Owner Address: 7721 INGRAM DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99502 - This permit is for the construction of: 0 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907)343-7904(24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Issued By. 0 Date: Date: '7 0, o Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. DlI-IZ(-% Property owner(s) "e-fti . n Day phone '2'40'_4 _? 6g Mailing Site address Code 89502 Code Legal description (Sub'd, Block & Lot) LA 2C Li.ncai� Aeric 7 Legal description (Township, Section & Range) Lot Size 11;� 01-1 Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field a Septic Tank E9 Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms L/ THIS APPLICATION IS AN: Initial 0 Upgrade ❑ Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Le.... s.L. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: 1 'rVI Waiver Fees: Date of Payment: Receipt Number: 0 3�g Receipt Number: (Rev. 11/05) it SPUMand Efl&ewoflg _ Environmental Consuming and Design SEPTIC SYSTEM PERMIT APPLICATION LOT 2E KINCAID ACRES Municipality of Anchorage July 21, 2006 Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 Subject: ON-SITE SEPTIC SYSTEM PERMIT APPLICATION (SW970105) LOT 2E KINCAID ACRES Gentlemen: We arc re -submitting an application for the installation of a septic system for this lot. The septic system was designed by Tobben Spurkland on May 2, 1997. A document search and site visit conducted July 19th, 2006 indicated that site conditions have not changed substantially during the last 9 years. The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the arca. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions, please contact me at 279-3916. Sincerely, Lo -o 5 Lars Spurkland, P.E. Spurkland Engineering 203 West 15`h Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (907) 276-6013, SpurklandEng@gci.net �.�:IX IW .'�][.,�.RI'i F.F. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907)279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 2E KINCAID ACRES JEFF HANSEN Municipality of Anchorage Department of Health and Social Services 820 I Street Anchorage, Alaska 99501 May 2, 1997 We are submitting an application for the installation of a septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: Public Water System No Ground Water or Impervious Layer to 20 ft. Use Standard Trench Soil Rating. 5.33 min/in - 0.8 gal per sq.ti/day No. of Bedrooms 4 Required Area per Bedroom: 150/.8 - 187 sq.R.. Total area required: 187 x 4 - 748 Testhole depth 20 feet Bottom Rock At 1 I feet Top Rock At 4 feet Rock Depth 7 feet Total Trench Length 748 / 14 a 53.4 ft. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 55 FT TOTAL WIDTH 2 F TOTAL DEPTH 11 FT ROCK DEPTH 7 F COVER 4FT 1250 GAL SEPTIC TANK The installation of this septic system will not prevent wells from being ins, tlled on the adjacent lots. There are no developed or natural surface / sub surface drainage courses n.t this or the adjacent lots. The proposed septic system will not change the general slope of the area.',*onding and/or concentration of surface runoff will not result from this installation. IA IB ¢ IVell IC VACANT L I 2A IW r Tx V � � I ti I 2B 1 I I I 2F Q X15 � KB III I � I i I IVeI/ 2C .Y I I I ----- —/— -- tZ,�- I 1 LOT 3 VACANT 50 0 50 100 150 700 250 300 SCALE: P = 100 FT. I VACANT I 49th �•. I 17 -71 -.'TUB EN- ... SPURKLAND•'; TOBB£N SPURXLAND P.E. L07' ZE KINCAID ACRESSEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE DATE. APRIL 13, 1997 ANCH. AK. 99501 JEFF HANSEN SHEET: 1/3 GRID: 2222 907 279-3916 11 PERMIT # PTD k KCA002EI.DVG - - - - - - - - - - - - - - I - - - - - - - - - - - - - - I 1 I I I I I I = I I I it1 I I I I I I I I I I I � I I I - - PROP SED 4 BEDROOM SFa I I I I I I 1 TH 1 50 AL SEPT C TA 1 I I I• PR! ARY T N 11 FT £P I 1 T L 1 1 SE W£R�OCr I PL EM£ TRENC ----- -- t �«�♦�_ -- -------J __ L---- __ ---- J.Z'� _. TDB • N SPURKLAIM •� ��p s o ♦Icy t �. CE -2225 ? �� • 25 0 25 50 75 100 125 150 SCALE., 1' = 50 FT. IOBBEN SPURKLAND P.E. LOT 2E KINCAID ACRES SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE DATE. APRIL 23, 1997 ANCH. AK. 99501 907 279-3916 JEFF HANSEN SHEET: 2/3 GRID: 2222 PERMIT s PID y KCA002E2.DWG Monitor 1250 gal Septic tank Standard Trench: ° 2' Wide 54' Long 11' Deep 7' Sewer rock 3' Cover Foundation Clean out NO SCALE Cleanouts Monitor 3' Cover SIL T 7 Ft of Septic Rock 9th i No. CE -2225 Clean Out 4' Min Cover over r Tank 1250 gal. septic tank NO SCALE ° 6 n BENCH MARK. ASSUMED ELEV. 100.00 I UBBLN SPURKLAND P.E. LOT 2E KINCAID ACRES SEPTIC SYSTEM DESIGN 203 W15th Ave SEPTIC SYSTEM SCHEMATIC DATE- APRIL 23, 1997 Anchorage Ak 99501 SHEET- 3/3 GRID: 2222 1+0-1014 JClf N4NSCN PERMIT N0: P.I.N. KCA002E3.DPIG 64 71Ct �So�vvt I ^A",A a W W yl X13 6�•� 73� F. t 7G3 , 2� ,Yh 70 • . o • a > V� 3� Ot a GA Y - I r Munlcipailty of Anchorage DEPARTMENT OF I IEALTH d HUMAN SERVICES 825 `L' Street, Anchorage, Alaska 69502-0650 SOILS LOG — PERCOLATION TEST ` PEnFORMED FOn: TOM LI AI DD IA! TEST PIT 4 I DATEPE LEGAL DEscmprtON:TP-A[-T I KINCAIp ACJ;ESTownship, Range. Section: ✓ 02E4-AAfIGS SLOPE SITE PLAN 1✓ / � ✓ L2011A1 DRi 2 ✓ C241nrJIL SILT 1 �i C E7 SILT I w.l S..nE co8!?LES 4 � /. 5 � 6 6iREY DAY SILTY >A,jD 71.- / I 6 9 10 11 12 13 14 15 16 17 16 19 20 o, O C7 mom pato ©©■■■■■ _..■.. OMNI O-ISt13 Gto7 on E; -S 1.5 EMM MEMO 2`_l. 375 No c> NOON "15 1 ON a-15- % ON ti S. TS 1. ON :t3 mull oilmom SOML G.2AJEl... WAS ('.HOUND WATER ENCOUNTERED? C066L.05 Cj pNE -ND Slp6 @ Ir YFS, AT WItAT nPPRer , 1O• aPrnt>—�— BECooi t"Cct r4oQE StLT'r eArreoic 1151. 51(-T1f SAn10 / SANDY SILT F ALD @ 201 COMMENTS .MESOA4— 4115 O.rIA le Wele( R_lt_r1� Mon "inyT N colt. ' ■■ ��©■eN©■■■■ .moo pato ©©■■■■■ _..■.. Depth to Not Wean Drop O-ISt13 Gto7 to n•,ding pato *e Time Net Time Depth to Not Wean Drop O-ISt13 Gto7 to E; -S 1.5 2`_l. 375 c> S "15 1 "q. a-15- % :OL ti S. TS 1. :t3 •'T S,1. PFn(lOLATION RATE 5•33 ImmoleVinch) PERC HOLE OIAMETEn TEST num BETWEEN IS -S FTAND 10.6 FT "PERFORMED BY: GAR -L. A69AMS _I nern 14le•' — CERTIFY MAT TIIIS TEST WAS PERFORMED IN ACCOnnANCE WITH At L STATE AND MUNICIPAL liIIIOFLINES IN EFFECT ON THIS DA T. DATE: 77 MA Inw e.et1 1111t/ll WI �r MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970105 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:HANSEN OWNER ADDRESS:P.O. BOX 221921 ANCHORAGE, AK. 99522 PARCEL ID:01112196 LEGAL DESCRIPTION: KINCAID ACRES LT 2E LOT SIZE: 42071 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: PAGE 1 OF 1 DATE ISSUED: 5/22/97 EXPIRATION DATE: 5/22/98 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED B ISSUED BY: Y: DATE: p uL ^N DATE: ToSPLT,LANM P.E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 2E KINCAID ACRES JEFF HANSEN Municipality of Anchorage Department of Health and Social Services 820 I Street Anchorage, Alaska 99501 May 2, 1997 We are submitting an application for the installation of a septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following : Public Water System No Ground Water or Impervious Layer to 20 ft. Use Standard Trench Soil Rating. 5.33 min/in = 0.8 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 150/.8 = 187 sq.ft.. Total area required: 187 x 4 = 748 Testhole depth 20 feet Bottom Rock At 11 feet Top Rock At 4 feet Rock Depth 7 feet Total Trench Length 748 / 14 = 53.4 ft. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 55 FT TOTAL WIDTH 2 FT TOTAL DEPTH 11 FT ROCK DEPTH 7 FT COVER 4FT 1250 GAL SEPTIC TANK The installation of this septic system will not prevent wells from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. IA IB Well 1C VACANT 20D I --- — -- ----——las— _— ,, 2A I I I � 4 -BEDROOM DUPLEX � TH r 1 1 1 V � I I I I Q KB z Well 2C CLASS C 2 I i �TT I I VACANT I ---i L- -- -- - - j �90o:7 OF 4444* 0..... ....... '...........................; LOT 3 i...... ... ................. TOB N SPURKLAND j VACANT � O. CE -2225 �,•���� 50 0 50 100 150 200 250 300 SCALE. 1' = 100 FT TOBBEN SPURKLAND P.E. LOT 2E KINCAID ACRES SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE DATE: APRIL 23, 1997 ANCH. AK. 99501 JEFF HANSEN SHEET 1/3 GRID: 2222 907 279-3916 PERMIT # PID # KCA002E1,D VG — ,----— —- — ---——— �——---——- r I 1 I I I I I I I I I I I I I 2lo I 1 I I I � I I I I 1 I 1 A5 I I SED 9 BEDROOM SFP I I I I 1 I TH 1 50 GAL I SEPT C TA °I• PRI ARY T I 1 I NC=B! 11 FT EEP 1 2 2 T LO I PL EME TREP1i ,; SEWERROCY I I 1 I —--J L — — —— ---—— let............ —-—— — — — — —— •� mo 49th 0 .......r.. ......... ..... . '�� ' TUEF�f N SPURKLA �'� �90 s '� • I #♦ :, Jo. CE- 225 - 25 0 25 50 75 !00 125 150 SCALE 1"50 F 1. TOBBEN SPURKLAND P.E. LOT 2E KINCAID ACRES RES SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE ANCH. AK. 99501 DATE.- APRIL 23, 1997 907 279-3916 JEFF HANSEN SHEET.- 213 GRID: 2222 PER` .'T # PID # KCA002E2DWG Monitor Clean Out PRIMARY TRENCH Standard Trench - Double Clean Outs O 1250 gal Septic tank O z' Wide 54' Long 11' Deep 7' Sewer rock 3' Co ver Foundation Clean out NO SCALE SIL T BARR 7 Ft of Septic Clean Out .°• 49th TOEN SPURKLAND ✓' %, No. CE -2225 '•�� , pR0 FE S S �' ' "' ASSUMED ELEV, 100,00 I TOBBEN SPURKLAND P.E. L 0 T 2E KINCAID ACRES SEPTIC SYSTEM DESIGN 203 W15th AveDATE: APRIL 23, 1997 Anchorage Ak 99501 SEPTIC SYSTEM SCHEMATIC icrr unuccu SHEET 313 GRIDS 22c`'2 I PERMIT NO: P.I.N. KCAO02E3.DWG Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "V Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: TONt L MDOV� Tc ST P11- 4 ( DATE P LEGAL DESCRIPTION: TFAc-T I KINC A I p A Cke &Township, Range, Section: ✓ kl�. O(16tArJ I C $ SLOPE SITE PLAN _ 1 2 3 ✓/ � � ✓Anl tSRold1.1 DIZ7' IG SI t,T S E E CE% OS12�1Cwl SeMtE co&8l ES S I T dF- �✓ 16 Net Drop SrLT`i @ APP2ox 17 L A r� 5 � 1-5 51LTy SA^(D / 1e 6 '�: � 6iREY DR -Y 5LLT7 S�,„!D Y 20 1-875. E_ ALD @ go' o 7�%' " 8 7:07- y s.g1s I g .. i 9- ♦ ."lS 1. 10 10- SOMC- C -t. RAVCL. WAS GROUND WATER ND o COggL�S dJ oaf ENCOUNTERED? 11 SISS @ — Q b �PPQo I EYES, AT WHAT " 0 12 la 13 • . la w41er'A'n_e�r - CMunilcring?NJ_ Oslt IO-� 93 / 14 15 Date BECo�+tr�Cz N1oRE � 16 Net Drop SrLT`i @ APP2ox 17 � IS l S• S 1-5 51LTy SA^(D / 1e ,� s�Noy srt_T S. is 147S �I Y 20 1-875. E_ ALD @ go' Reading Date oss Time Net Time Depth to Water Net Drop 4- 10-15-13 6p' o-7 10 S• S 1-5 (cv ° S. is 147S �I Y TS 1-875. o " 7:07- y s.g1s I g .. i :13 ♦ ."lS 1. PERCOLATION RATE immutes/inch) PERC HOLE DIAMETER 1 t TEST RUN BETWEEN 8•S FT ANO 10-S FT COMMENTS FSOO��- 4 V -S - - Y'PERFORMED BY: CAP -U A6RAMS I _F.7EE Nlevd CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 12-008 (nev. 4)85)