HomeMy WebLinkAboutKING #1 BLK 2 LT 4 ~MUNIClPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 b Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOEATION TEST PERCO LATIOr,~ TEST PERFORMED FOR: King Sub LEGAL DESCRIPTION: Lot 4 DATEPERFORMED: April 14, 1984 2 3 SM4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O Organics Silty. Clayey Sand sample SLOPE o%5% SITE PLAN SE~2 P]AT Silty Layey Large Cobbles and Rocks WAS GROUND WATER S ENCOUNTERED? NO L O P E IF YES, AT WHAT DEPTH? COMMENTS 349 Sq. Ft. per bedroom Gross Net Depth to Net Reading Date Time Time Water Drop 5-3 4-14-84 12:17 5.35 4-14-84' 12:27 10 .05 ft 5.5 4-14-84 12:37 10 .15 ft 5.61 4-14-84 12:47 10 .09 ft 5.66 4-14-84 1.17 20 .05 ft PERCOLATION RATE 40 ~LLnutes (minutes/inch) TEST RUN BETWEEN 5 FT AND --5°5 FT Hole pre-soaked prior to test Tony Wilson RFORMEDBY: CERTIFIED BY: John Lovett DATE: 4-16-84 DICKINSON-OSWALD & PARTNERS ENGINEERS AND SURVEYORS PHONE 907 277-16SE 800 CORDOVA STREET ANCHORAGE, ALASKA 99501 July 2, 1973 Mr. Rolf Strickland Greater Anchorage Area Borough Department of Environmental Quality 3330 "C" Street Anchorage, Alaska Re: Well Location, Addition No. 1 _King Subdivision for John D. Gibbons Dear Rolf: Attached is a print of 54-31 for subject subdivision, showing a proposed welt location on Lot 4, Block 2. This will be a 6" well, intended to serve 3 or 4 lots in the vicinity. We are requesting your approval of this location. If you concurr we will proceed with the preparation of a formal well protection easement document and record same. Very truly yours, DICKINSON-OSWALD & PARTNERS ~ Lewis E. ~kinson, Partner LED: gr Altachment cc: ~6r. John D. Gibbons LEWIS E. DICKINSON, P.E. NIAURICE P. OSWALD, LS. KENNETH B. WALCH, P.£. ~un~ 27, 1973 John ~. 6ibbons llO1 ~'/es~ .S3rd Ave~ue Arlci~orage, Alaska Sucject: Addi:ion i~l, King Subdivision Uear ~4r. Gibbons: The Greater Anchorag(~ Area ~orougl) Department of Environ)~n~al Quality ,,till approve the use of a sewage holding tank ~o serve industrial ~,arehouse construction in this subdivision. We will also ~xpec~ the subdivision to be served by a co~unity water syster~l. This is tn accordance with th~ note placed o~l the offi- cial recorded plat dated Janua~ 25, 1973. Should you have need for additioi-~al i~fom~ion in regards to this subdivision, please contact the undersigned. Since~ly~, cKlanu ~ l~.S. Roll Stri ' '~ ' Chief Sanitarian told DICKINSON-OSWALD & PARTN June 25, 1973 Mr. Rolf Strickland, Sanitarian Greater Anchorage Area Borough Department of Environmental Quality 3330 "C" Street Anchorage, Alaska Dear Rolf: On October 4, 1972, the Platting Board approved Dimond Ind~ u~s~t_rial Subdivision qS-2834) and Addition No. 1 of ~ ~sion (S-2331). Both plats were prepared by DICKINSON-OSWALD & PARTNERS and both adjoin each other adjacent to King Street. Addition No. 1 to King Subdivision was subsequently recorded on January 25, 1973, with a note reading "This subdivision, at the time of filing, is not served by public water and sewer fac- ilities. No on-site water and/or sewage facilities (including sewage holding tank designs) may be constructed without prior ap- proval of the G.A.A.B. Health Department. Construction of resi- dences will not be permitted until public water and sewer are available." The purpose of this letter is to request your written ap- proval to use this same note in the final plat of Dimond Indust- rial Subdivision. Thanki.ng you in advance for your assistance in this matter. Sincerely, DICKINSON-OSWALD & PARTNERS Donald G. Beckord, ASLA DGB/vms .~: LEWIS E. DICKINSON, P.E. MAUR CE P OSWALD, L.S. KENNETH B. WALL:H, P.£,