HomeMy WebLinkAboutMEADOW RIDGE ESTATES BLK 1 LT 2
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241019
Work Type: SepticTank Upgrade
Tax Code Number: 05146104000
Site Legal Address: MEADOW RIDGE ESTATES BLK 1 LT 2 G:1362
Site Mailing Address: 21112 MEADOW LAKE DR, Chugiak
Owner: SULLIVAN ANDREW V & ALICE B
Design Engineer: NORTH RIM ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
1
De partill ell t
3/13/2024
3/13/2025
24897
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
I ved-B eA fio /Orli f� 1i '
Issued By:
Date:
Date: 3 Z c
3
��/�UMMPAUTY OF " HCHOG�aGrr--
Development Services Department � /J Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 05146104000
Property owner(s) SULLIVAN ANDREW
Mailing address 21112 MEADOW LAKE DR
Site address same
Day phone 688-4128
Legal description (Sub's., Block & Lot) MEADOW RIDGE ESTATES BLK 1 LT 2
Legal description (Township, Range & Section)
Lot Size 24,897 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(N all that apply)
Absorption Field ❑ Initial
❑
Single Family (SF) 0
Septic Tank El Upgrade
(w/wo AD U)
Holding Tank ElRenewal
ElDuplex
(D) E]
Privy ❑
Multiple Dwellings ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
certify that the above information is correct. I further
certify that this
is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: Z
Waiver Fees:
Date of Payment: 2- "-20 2 `1
Date of Payment:
Receipt Number:
Receipt Number:
Permit No. 0 (g
Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
SteveEng.com Meadow Ridge Estates B1 L2
SPECIFICATIONS & DESIGN GUIDELINES
Wastewater System Sizing: The current septic tank has failed- the seepage trench still
functions. This lot is close to a half-acre and on public water . No adverse impacts are
expected from tank replacement. Easements are depicted on the lot. The slope is
negligible in the area of the septic system. No conflicts to neighbor properties.
Specification Requirements: All components and work must comply with the
Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water
Regulations and Wastewater Regulations.
New 2- compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet.
5 minimum between the tank and trench. 5 to property lines & 10 to house.
4 of cover or insulation is required for tank; an equivalent of 1 insulation for 1 foot
soil cover. Tank & solid pipe must be set on well compacted, stable soil.
No large rocks for tank bedding. Plastic/fiberglass tanks require special bedding per
MOA- sand or pea gravel.
4 diameter cleanouts with airtight caps are required 1 to 4 from foundation wall,
prior to any 90 degree bend in 4 inch line, in 2 nd tank compartment, and two adjacent
opposing cleanouts between the tank and the absorption field, not more than 10 from
the tank positioned to provide cleanout access towards the tank and towards the
absorption field. Manhole Riser required in 1 st tank compartment.
All cleanouts must extend to at least ground level.
In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
Insulation must be placed over any pipe installed under driveways or parking areas.
Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661,
Sewer Service Line is minimum 2% slope.
Septic Tank to be pumped every two years or when required.
Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal)
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241019, Deb Wockenfuss, 03/13/24
/CARPORT
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241019, Deb Wockenfuss, 03/13/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241019, Deb Wockenfuss, 03/13/24
TRACT B-1
LOT 1
BLOCK 1
LOT 2
BLOCK 2
ASPLS MORTGAGE LOCATION SURVEY NOTES:
NO TITLE REPORT WAS PERFORMED FOR THIS SURVEY, EASEMENTS SHOWN PER THE
RECORD PLAT. THERE MAY BE ADDITIONAL EASEMENTS NOT SHOWN HEREON. THIS
MORTGAGE LOCATION SURVEY HAS BEEN PREPARED IN ACCORDANCE WITH ASPLS
MORTGAGE LOCATION SURVEY STANDARDS. IT IS A REPRESENTATION OF THE
CONDITIONS THAT WERE FOUND AT THE TIME OF THE SURVEY. THIS SURVEY DOES
NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT
A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. THE INFORMATION CONTAINED IN
THIS DRAWING SHALL NOT BE USED TO ESTABLISH ANY FENCE, STRUCTURE, OR
OTHER IMPROVEMENTS. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY
EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED
FOR SERVICES IN PREPARATION OF THIS PRODUCT.
LEGEND
( ) RECORD DATA PER PLAT #72-261
o FOUND 1/2" REBAR, NO CAP
\O FOUND 3/4" REBAR, NO CAP
— EDGE OF ASPHALT
& 4" PVC SEPTIC PIPE
FA DECK
NOTE: WATER SUPPLY IN THIS SUBDIVISION IS VIA COMMON WELL
0' 30' 60'
SCALE: F'= 30 FEET
(11"x17")
WINTER SURVEYNOTE: +/- 2.5 FEET OF
SNOW ON-SITE AT TIME OF SURVEY. ONLY
VISIBLE IMPROVEMENTS SHOWN HEREON.
�. 0F. A�gsl
j *•••49TH.... •:*
J
-.Ryan G Johnson;
r�+I,••No. 192159 ,•Aw
��. 3/12/2024. •SAW
AS -BUILT OF:
MUNICIPALITY OF ANCHORAGE
" DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
!~-~ ~.~, ~]/' ~ ~'"~ ~ ENVIRONMEN 1'AL ENGINEERING D I VI SION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
N A'~'~'-~"'~ . ~"'~ / PHONE
LEGAL DESCRIPTION
LOCATION
~,~: [ DISTANCE TO:
~'~ <~ l Manufacturer
DISTANCE TO:
DISTANCE TO:
No. of lines/
'FWeII/j Absorption arJ~
./
IF HOMEMADE: inside length
Width
Type of crib Crib diamet~,~////~--
Well
DISTANCE TO:
Class C- ~
Material
Found ' ]~.~,~ [ r~_ ]Neare~line~/
Total ~z-e f ,~e~
M~ri~benegm ti)~ ~ ~
[ Ceptbr
Buildin9 foundation
NO. OF BEDROOMS
PERMIT N O.:/~
No, of compartr~s
Liquid depth
PERMIT NO,
Liquid capacity in gallona
PERMIT NO,
[] UPG RAD[-'
Total effective absorption aCea
PERMIT NO.
._.Crib depth Total effective absorption area
Building foundation Nearest Jot line
~Dr~ller
Sewer line
DISTANCE TO:
OTHER
PIPE MATERIALS
SOIL TEST RATING ,'r~%~ Y~'>/~/~L,~
REMARKS
Distance to lot line
PERMIT NO,
Absorpt on area(s)
Septic tank
APPROVED
72-013 (Rev. 3/78)
DATE
Department
825
264-4720
/~.~ * * * HANDWRITTEN PERMIT * * *
Permit ~ ,../c~ WELL AND/OR ON-SITE SEWER PERMIT
Applicant: ~C[~_ <C~,1 /,,~,LD-~ Mailing Address:
Location: Phone Number:
Legal Description: ,~O ~//~/~
Type of Soil Absorption System Is:
Trench: X' Drainfield: _ Seepage Bed:
MUNI~IFALI iY U~ AI~MUNA~C
Health and Environmental ~rotection
Street, Anchorage, AK. ~501
Lot Size:
Holding Tank:
Maximum Number of Bedrooms: ~- Soil Rating(sq.ft/br) /
The Required Size of the Soil Absorption System Is:
C1 C/S ~": WIDTH
DEPTH LENGTH , GRAVEL DEPTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
* * REQUIRED SEPTIC(HOLDING) TANK SIZE = /L¢C~<3 GALLONS *
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells a[j~cent to this p~opezt[ and the numbe~
of residences that the we[l will serve.
* * * TWO(2) INSPECTIONS ARE REQUIRED * * *
B~ckfilling of ~n~ s~stem without final inspection an~ ~pprov~l by this
will be subject to prosecution.
Minimum distance between a well ~nd any on-site sewage disposal system is 100 feet
for ~ private well o= 150 to 200 feet from ~ public well de~e~di~g ~pon %he
of public well. ~inim~ distance from a private well to ~ private sewe~ line
is 25 feet and to ~ coAunit[ sewer line is 75 feet. ~ell logs ~=e requized
8~d B~S~ be ~et~ned to this dep~rtDe~t withi~ 30 da~s of the well coDpietion.
Other requirements m~[ apply. Specifications and construction diagrams are
available to insure p=opez installation.
* * * P'bRMIT EXPIRES DECEMBER 31, 1 9 8 3 * * *
I certify that:
(1) I ~ f~iliar with the =equi=ements for on-site sewers ~nd wells
set forth by the Municipality of ~chorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the res~denc~e/ is ,remodeled
/kp~lic~ant -
that ,~ bedroom's,~
to include more-/ /// ///C~i~ /,/~
SWP/024(1/81)
F,ql- }~!,.1~ ii' £)1{ .
bG/~,L DESCIIIPllON
~A'i [~ P:RFDI',i"d i
APPLI(:,, NT FILLS OUT UPPER HAL ONLY
Buyer
Address Zip Code
~' Phone
Zip Code
Type of Residence
¢ingle Family
~ Multiple Family No. of Bedrooms
F~ Other
Water Supply
~ Individual ATTACH WELL LQG. A well log is required for all wells drilled since June 1975.
~ommunity For wells drilled prior to that date, give well depth (attach log if available).
~ Public Utility
~dividual Year Individual Installed:
~ Public Utility When Connecled to Public Utility:
~ Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED.
Time
Date
Inspector
Time
Date
Inspector
Time
Date
i Inspector
Time
[)ate
Inspector
Field Notes:
'~ APPROVED BEDROOMS ) DISAPPROVED
( } CON DITIONAL,APPRgVAL*
DATE ~/~'~/.~h
*CONDITIONS OF APPROVAL
Soils Rating
Date Sewer Installed
Well To Absorption Area
Well to Tank
Well Log Received
Septic Tank Size