Loading...
HomeMy WebLinkAboutMEADOW RIDGE ESTATES BLK 1 LT 2 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241019 Work Type: SepticTank Upgrade Tax Code Number: 05146104000 Site Legal Address: MEADOW RIDGE ESTATES BLK 1 LT 2 G:1362 Site Mailing Address: 21112 MEADOW LAKE DR, Chugiak Owner: SULLIVAN ANDREW V & ALICE B Design Engineer: NORTH RIM ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 1 De partill ell t 3/13/2024 3/13/2025 24897 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing I ved-B eA fio /Orli f� 1i ' Issued By: Date: Date: 3 Z c 3 ��/�UMMPAUTY OF " HCHOG�aGrr-- Development Services Department � /J Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 05146104000 Property owner(s) SULLIVAN ANDREW Mailing address 21112 MEADOW LAKE DR Site address same Day phone 688-4128 Legal description (Sub's., Block & Lot) MEADOW RIDGE ESTATES BLK 1 LT 2 Legal description (Township, Range & Section) Lot Size 24,897 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) 0 Septic Tank El Upgrade (w/wo AD U) Holding Tank ElRenewal ElDuplex (D) E] Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Z Waiver Fees: Date of Payment: 2- "-20 2 `1 Date of Payment: Receipt Number: Receipt Number: Permit No. 0 (g Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc SteveEng.com Meadow Ridge Estates B1 L2 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: The current septic tank has failed- the seepage trench still functions. This lot is close to a half-acre and on public water . No adverse impacts are expected from tank replacement. Easements are depicted on the lot. The slope is negligible in the area of the septic system. No conflicts to neighbor properties. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. New 2- compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet. 5 minimum between the tank and trench. 5 to property lines & 10 to house. 4 of cover or insulation is required for tank; an equivalent of 1 insulation for 1 foot soil cover. Tank & solid pipe must be set on well compacted, stable soil. No large rocks for tank bedding. Plastic/fiberglass tanks require special bedding per MOA- sand or pea gravel. 4 diameter cleanouts with airtight caps are required 1 to 4 from foundation wall, prior to any 90 degree bend in 4 inch line, in 2 nd tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10 from the tank positioned to provide cleanout access towards the tank and towards the absorption field. Manhole Riser required in 1 st tank compartment. All cleanouts must extend to at least ground level. In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. Insulation must be placed over any pipe installed under driveways or parking areas. Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, Sewer Service Line is minimum 2% slope. Septic Tank to be pumped every two years or when required. Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241019, Deb Wockenfuss, 03/13/24 /CARPORT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241019, Deb Wockenfuss, 03/13/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241019, Deb Wockenfuss, 03/13/24 TRACT B-1 LOT 1 BLOCK 1 LOT 2 BLOCK 2 ASPLS MORTGAGE LOCATION SURVEY NOTES: NO TITLE REPORT WAS PERFORMED FOR THIS SURVEY, EASEMENTS SHOWN PER THE RECORD PLAT. THERE MAY BE ADDITIONAL EASEMENTS NOT SHOWN HEREON. THIS MORTGAGE LOCATION SURVEY HAS BEEN PREPARED IN ACCORDANCE WITH ASPLS MORTGAGE LOCATION SURVEY STANDARDS. IT IS A REPRESENTATION OF THE CONDITIONS THAT WERE FOUND AT THE TIME OF THE SURVEY. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. THE INFORMATION CONTAINED IN THIS DRAWING SHALL NOT BE USED TO ESTABLISH ANY FENCE, STRUCTURE, OR OTHER IMPROVEMENTS. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. LEGEND ( ) RECORD DATA PER PLAT #72-261 o FOUND 1/2" REBAR, NO CAP \O FOUND 3/4" REBAR, NO CAP — EDGE OF ASPHALT & 4" PVC SEPTIC PIPE FA DECK NOTE: WATER SUPPLY IN THIS SUBDIVISION IS VIA COMMON WELL 0' 30' 60' SCALE: F'= 30 FEET (11"x17") WINTER SURVEYNOTE: +/- 2.5 FEET OF SNOW ON-SITE AT TIME OF SURVEY. ONLY VISIBLE IMPROVEMENTS SHOWN HEREON. �. 0F. A�gsl j *•••49TH.... •:* J -.Ryan G Johnson; r�+I,••No. 192159 ,•Aw ��. 3/12/2024. •SAW AS -BUILT OF:  MUNICIPALITY OF ANCHORAGE " DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION !~-~ ~.~, ~]/' ~ ~'"~ ~ ENVIRONMEN 1'AL ENGINEERING D I VI SION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT N A'~'~'-~"'~ . ~"'~ / PHONE LEGAL DESCRIPTION LOCATION ~,~: [ DISTANCE TO: ~'~ <~ l Manufacturer DISTANCE TO: DISTANCE TO: No. of lines/ 'FWeII/j Absorption arJ~ ./ IF HOMEMADE: inside length Width Type of crib Crib diamet~,~////~-- Well DISTANCE TO: Class C- ~ Material Found ' ]~.~,~ [ r~_ ]Neare~line~/ Total ~z-e f ,~e~ M~ri~benegm ti)~ ~ ~ [ Ceptbr Buildin9 foundation NO. OF BEDROOMS PERMIT N O.:/~ No, of compartr~s Liquid depth PERMIT NO, Liquid capacity in gallona PERMIT NO, [] UPG RAD[-' Total effective absorption aCea PERMIT NO. ._.Crib depth Total effective absorption area Building foundation Nearest Jot line ~Dr~ller Sewer line DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING ,'r~%~ Y~'>/~/~L,~ REMARKS Distance to lot line PERMIT NO, Absorpt on area(s) Septic tank APPROVED 72-013 (Rev. 3/78) DATE Department 825 264-4720 /~.~ * * * HANDWRITTEN PERMIT * * * Permit ~ ,../c~ WELL AND/OR ON-SITE SEWER PERMIT Applicant: ~C[~_ <C~,1 /,,~,LD-~ Mailing Address: Location: Phone Number: Legal Description: ,~O ~//~/~ Type of Soil Absorption System Is: Trench: X' Drainfield: _ Seepage Bed: MUNI~IFALI iY U~ AI~MUNA~C Health and Environmental ~rotection Street, Anchorage, AK. ~501 Lot Size: Holding Tank: Maximum Number of Bedrooms: ~- Soil Rating(sq.ft/br) / The Required Size of the Soil Absorption System Is: C1 C/S ~": WIDTH DEPTH LENGTH , GRAVEL DEPTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /L¢C~<3 GALLONS * Permit applicant has the responsibility to inform this department during the installation inspections of any wells a[j~cent to this p~opezt[ and the numbe~ of residences that the we[l will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * B~ckfilling of ~n~ s~stem without final inspection an~ ~pprov~l by this will be subject to prosecution. Minimum distance between a well ~nd any on-site sewage disposal system is 100 feet for ~ private well o= 150 to 200 feet from ~ public well de~e~di~g ~pon %he of public well. ~inim~ distance from a private well to ~ private sewe~ line is 25 feet and to ~ coAunit[ sewer line is 75 feet. ~ell logs ~=e requized 8~d B~S~ be ~et~ned to this dep~rtDe~t withi~ 30 da~s of the well coDpietion. Other requirements m~[ apply. Specifications and construction diagrams are available to insure p=opez installation. * * * P'bRMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * I certify that: (1) I ~ f~iliar with the =equi=ements for on-site sewers ~nd wells set forth by the Municipality of ~chorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the res~denc~e/ is ,remodeled /kp~lic~ant - that ,~ bedroom's,~ to include more-/ /// ///C~i~ /,/~ SWP/024(1/81) F,ql- }~!,.1~ ii' £)1{ . bG/~,L DESCIIIPllON ~A'i [~ P:RFDI',i"d i APPLI(:,, NT FILLS OUT UPPER HAL ONLY Buyer Address Zip Code ~' Phone Zip Code Type of Residence ¢ingle Family ~ Multiple Family No. of Bedrooms F~ Other Water Supply ~ Individual ATTACH WELL LQG. A well log is required for all wells drilled since June 1975. ~ommunity For wells drilled prior to that date, give well depth (attach log if available). ~ Public Utility ~dividual Year Individual Installed: ~ Public Utility When Connecled to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED. Time Date Inspector Time Date Inspector Time Date i Inspector Time [)ate Inspector Field Notes: '~ APPROVED BEDROOMS ) DISAPPROVED ( } CON DITIONAL,APPRgVAL* DATE ~/~'~/.~h *CONDITIONS OF APPROVAL Soils Rating Date Sewer Installed Well To Absorption Area Well to Tank Well Log Received Septic Tank Size